Sunteți pe pagina 1din 2

BEARING CAPACITY OF SHALLOW FOUNDATIONS

Terzaghi and Vesic Methods


Date
Identification

February 16, 2015


Example 6.4

Input

Results
Units of Measurement
E SI or E
Foundation Information
Shape
B=
L=
D=

SQ
1
1
2.5

SQ, CI, CO, or RE


ft
ft
ft

Soil Information
c=
phi =
gamma =
Dw =

110
0
120
10

lb/ft^2
deg
lb/ft^3
ft

Factor of Safety
F=

Copyright 2000 by Donald P. Coduto

Terzaghi
Bearing Capacity
q ult =
1,115 lb/ft^2
qa=
372 lb/ft^2
Allowable Column Load
P=
0 k

Vesic
1,297 lb/ft^2
432 lb/ft^2

0 k

Unit conve

1000

Gamma w
phi (radian

62.4
0

Terzaghi Computations
a theta =
1
Nc =
5.70
Nq =
1.00
N gamma
0.00
gamma' =
120
coefficient
1.3
coefficient
0.4
sigma zD'
300

Vesic Computation
Nc =
5.14
sc =
1.19
dc =
1.48
Nq =
1.00
sq =
1.00
dq =
1.00
N gamma
0.00
s gamma =
0.60
d gamma =
1.00
B/L =
1
k=
1.19029
W sub f