Heavy Duty Motor Starters

Wiring

Class 14
3 Phase and 1 Phase Magnetic Starters

ESP100 3 Phase Sizes 04

Ambient Compensated
Single Phase Sizes 00212

Ambient Compensated
3 Phase Sizes 004

ESP100 3 Phase Sizes 67

CIRUIT
PROTECTION
DEVICE
(IF USED)

NEMA and HP
Rated Control

ESP100 3 Phase Sizes 412, 5

CIRCUIT
PROTECTION
DEVICE
(IF USED)

MOTOR

MOTOR

3 Phase Sizes 1343


Applied on Single Phase

ESP100 Single Phase Sizes 01 (0.25 to 16A)

The device must be wired with polarity as shown.


Neutral and L1 wires must be wired as indicated on the
drawing, polarity is indicated by
.

an approximate setting of a Single Phase motor


application, multiply the motor nameplate by .75 and
set the dial on the overload to the resulting value.

For

157
Siemens Industrial Control Products

Combination Magnetic Starters

Wiring

Class 17, 18
Three Phase Solid State and Thermal Overloads
Size 412, 5

Size 04
TO SUPPLY
L1

L2

L3

B
3

A
CONTROL FUSES
(OPTIONAL)

M W

1
T1

T2

CIRUIT
PROTECTION
DEVICE
(IF USED)

ALTERNATE
CONNECTIONS FOR
TRANSFORMER

DISCONNECT or
CIRCUIT BREAKER

T3

OVERLOAD RELAY

NEMA and HP
Rated Control

95

"C"

T2
T1

SEC FUSE
XF
H4

96

T3

MOTOR

X1

H2
SEC
H3

X2

H1

REMOVE WIRE "C" IF CONTROL TRANSFORMER


IS USED. FOR SEPARATE CONTROL VOLTAGE
SOURCE, REMOVE JUMPERS "A" AND "B" AND
CONNECT SOURCE TO CONTROL FUSE LINE TERMINALS.

Size 6, 7

CIRCUIT
PROTECTION
DEVICE
(IF USED)

MOTOR

158
Siemens Industrial Control Products

Reversing Heavy Duty Starters

Wiring

Class 22
Three Phase Solid State Overload
Size 412, 5

Sizes 24

Sizes 0134

INCOMING LINE

CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
"REV"
CONTACTOR

"FWD"
"FWD"
CONTACTOR
CONTRACTOR

MECHANICAL

INTERLOCK

CURRENT
TRANSFORMER
(WHEN USED,
SEE TABLE)

O.L.
RELAY
(IF USED)

Three Phase Ambient Compensated Bimetal Overload

NEMA and HP
Rated Control

REMOVE WIRE "C" IF THE CONTACTOR


COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

Sizes 04

Single Phase Ambient Compensated Bimetal Overload


4 Wire Split Repulsion Induction 3 PoleSizes 0134

4 Wire Split Phase All Leads Broken 4 PoleSizes 0134

4 Wire Split Phase One Line Direct 3 PoleSizes 0134

3 Wire, 2 PoleSizes 0134

159
Siemens Industrial Control Products

Combination Reversing Starters

Wiring

Class 25, 26
3 Phase Overloads
Size 04
TO SUPPLY
L1

L2

L3

ALTERNATE CONNECTIONS
FOR TRANSFORMER

DISCONNECT or
CIRCUIT BREAKER

B
A
3

10

9
V FOR W

6 5

8
V REV W

4
T1

T2

T3

CONTROL FUSES
(OPTIONAL)

OVERLOAD RELAY

95

SEC FUSE
XF
H4

96

NEMA and HP
Rated Control

T2
T1

X1

H2
SEC
H3

T3

X2

H1

REMOVE WIRE "C" IF CONTROL TRANSFORMER


IS USED. FOR SEPARATE CONTROL VOLTAGE
SOURCE, REMOVE JUMPERS "A" AND "B" AND
CONNECT SOURCE TO CONTROL FUSE LINE TERMINALS.

Size 412, 5

INCOMING LINE

CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
"REV"
CONTACTOR

"FWD"
"FWD"
CONTACTOR
CONTRACTOR

MECHANICAL

INTERLOCK

CURRENT
TRANSFORMER
(WHEN USED,
SEE TABLE)

O.L.
RELAY
(IF USED)

REMOVE WIRE "C" IF THE CONTACTOR


COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

160
Siemens Industrial Control Products

Multi Speed Magnetic Starters

Wiring

Class 32 Size 04 (Typical)


1 Winding Constant Horsepower Size 013/4

TO SUPPLY

TO SUPPLY
L1

L2

L1

L3

L2

L3

DISCONNECT or
CIRCUIT BREAKER

ELEMENTARY DIAGRAM

DISCONNECT or
CIRCUIT BREAKER

WIRING DIAGRAM

T4

HI
T6

OL-HI

HI

LO

T3

T4

T1

LO

HI

T5
T5

LO
T1

T6

T2

CONSTANT HORSEPOWER
MOTOR

OL-LO

LO

T2

6 5

LO

1
3 8
V HI W

V LO W

T3
ALL OL'S
96

95

1 STOP

HIGH

LO

8
HI

OVERLOAD RELAY

HI

95
LOW

FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPER "A" AND


CONTROL WIRE FROM "1" ON STARTER. CONNECT SOURCE TO "1" ON
CONTROL DEVICE AND TO "96" ON OVERLOAD RELAY.

T1

HI

96
T2

OVERLOAD RELAY

95

96

T6

T3

T5

LO

T4

LO

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5

T1
T2
T3
T4
T5
T6

MOTOR

NEMA and HP
Rated Control

1 Winding Constant Horsepower Size 24


TO SUPPLY

TO SUPPLY
L1

L2

L1

L3

DISCONNECT or
CIRCUIT BREAKER

L2

L3

DISCONNECT or
CIRCUIT BREAKER

ELEMENTARY DIAGRAM
T4

WIRING DIAGRAM

HI
T6
L

OL-HI

HI

HI

T3

T4

T1

L
T5
T5

LO
T1
LO

T2

8
V L W
T6

T4

T5

OVERLOAD RELAY

LO

V HI W

T6

T2

CONSTANT HORSEPOWER
MOTOR

OL-LO

95

T3

96

ALL OL'S
96
1

95

STOP

HIGH

LO

8
HI

HI
1

LOW

FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPER "A" AND


CONTROL WIRE FROM "1" ON STARTER. CONNECT SOURCE TO "1" ON
CONTROL DEVICE AND TO "96" ON OVERLOAD RELAY.

HI

7
L

LO

V LO W

LO

T1 T2

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5

T3

OVERLOAD RELAY

95

96

T1
T2
T3
T4
T5
T6

MOTOR

1 Winding Constant or Variable Torque Size 013/4

TO SUPPLY
L1

L2

TO SUPPLY
ELEMENTARY DIAGRAM

L3

L1

DISCONNECT or
CIRCUIT BREAKER
LO
HI

OL-LO

T2
HI

LO

T3

T2

T5

WIRING DIAGRAM

L3

T1

T3

T1
LO

L2

DISCONNECT or
CIRCUIT BREAKER

T4

T6

CONSTANT TORQUE MOTOR


T4

HI
T6
HI

6 5

OL-HI

T2

T5

T5
95

1 STOP

LOW

HI

OVERLOAD RELAY

95

LO

FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPER "A" AND


CONTROL WIRE FROM "1" ON STARTER. CONNECT SOURCE TO "1" ON
CONTROL DEVICE AND TO "96" ON OVERLOAD RELAY.

T6
5

LO

6
LO

HIGH

1
3 8
V LOW W

V HIGH W

T6

VARIABLE TORQUE MOTOR

ALL OL'S
96

T1

T3

T4
HI

96
T4

OVERLOAD RELAY

95
T1

T5

96
T3
T2

HI
HI

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3

T1
T2
T3
T4
T5
T6

MOTOR

161
Siemens Industrial Control Products

Multi Speed Magnetic Starters

Wiring

Class 32 Size 04 (Typical)


1 Winding Constant or Variable Torque Size 24
TO SUPPLY
L1

L2

TO SUPPLY

T4

L3

L1

DISCONNECT or
CIRCUIT BREAKER

ELEMENTARY DIAGRAM

LO
H

OL-LO

LO

LO

T1
T2

T2

T5

V LO W

T2

T5

ALL OL'S

T1 T2

T4

96

T1

T3

OL-HI
T5

8
V H W

T4

T6

HI

WIRING DIAGRAM

T6

HI
HI

L3

CONSTANT TORQUE
MOTOR

T3

L2

DISCONNECT or
CIRCUIT BREAKER

T1

T3

T6

T3

OVERLOAD RELAY

VARIABLE TORQUE
MOTOR

95

96

95
2

1 STOP

LOW

HI

6
LO

LO

A
HIGH
4

1
5

LO

7
H

HI

V HI W

H
HI

2
NEMA and HP
Rated Control

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3

T6

T4

T5

OVERLOAD RELAY

95

96

T1
T2
T3
T4
T5
T6

FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPER "A" AND


CONTROL WIRE FROM "1" ON STARTER. CONNECT SOURCE TO "1" ON
CONTROL DEVICE AND TO "96" ON OVERLOAD RELAY.

MOTOR

2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 04


TO SUPPLY
L1

L2

TO SUPPLY

L3

L1

T2

DISCONNECT or
CIRCUIT BREAKER

L2

L3

DISCONNECT or
CIRCUIT BREAKER

ELEMENTARY DIAGRAM

WIRING DIAGRAM

LO
T1
LO

OL-LO

T1
T2

T3

T12

LO
T3
HI
T11
HI

OL-HI
T12

T11

HI

T13

ALL OL'S

2
95

HIGH
4

1 STOP

LO

8
HI

HI
LOW
2

6
T1

HI

T3

OVERLOAD RELAY

95
3

T2

7 4
T11 T12 T13
A

LO

FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPER "A" AND


CONTROL WIRE FROM "1" ON STARTER. CONNECT SOURCE TO "1" ON
CONTROL DEVICE AND TO "96" ON OVERLOAD RELAY.

T1
T2
T3
T11
T12
T13

OVERLOAD RELAY

95

96

LO

POSITION L1 L2 L3
LOW SPEED T1 T2 T3
HIGH SPEED T11 T12 T13

8
V HI W

TWO WINDING MOTOR

T13
96

V LO W

MOTOR

162
Siemens Industrial Control Products

96

Reduced Voltage Starters

Wiring

Class 36, 37 Size 04 (Typical)


Auto Transformer Starter

Two Step Part Winding Starter

2
NEMA and HP
Rated Control

Wye-Delta Starter
Open Transition

Wye-Delta Starter
Closed Transition

163
Siemens Industrial Control Products

Reduced Voltage Starters

Wiring

Class 36, 37 Size 41/2 7 (Typical)


Size 41/27
Autotransformer Starter (Typical)
TO SUPPLY

OPTIONAL
DISCONNECT
OR
CIRCUIT
BREAKER

NEMA and HP
Rated Control

Size 41/27
Part-Winding
CUSTOMER'S INC. LINE

POWER WIRING:
USE 75C, MINIMIUM
COPPER WIRE ONLY.

CIRCUIT
BREAKER

MOTOR

NEMA

size 6 and larger contactor coils are at line


voltage. NEMA size 6 and larger supplied with current
transformers.

164
Siemens Industrial Control Products

Reduced Voltage Starters

Wiring

Class 36, 37 Size 41/2 7 (Typical)


Wye Delta Open Transition
CUSTOMER'S
INC. LINE

OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER

2
NEMA and HP
Rated Control

Wye Delta Closed Transition


CUSTOMER'S
INC. LINE

OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER

NEMA

Size 5 and larger supplied with current


transformers.
Size 6 and larger contactor coils are at line voltage.

NEMA

165
Siemens Industrial Control Products

Magnetic Contactors and Reversing Contactors


Class 40, 43
3 Pole 3 Phase Magnetic Contactors and Reversing Contactors
3 Phase ContactorsSize 004

3 Phase Reversing ContactorsSize 004

2
NEMA and HP
Rated Control

3 Phase ContactorsSize 4125

3 Phase Reversing ContactorsSize 412, 5

INCOMING LINE

CIRCUIT
PROTECTIVE
DEVICE
(IF USED)

"C"
REMOVE WIRE "C" IF
CONTACTOR COIL
IS TO OPERATE ON A
VOLTAGE OTHER THAN
LINE VOLTAGE OR ON A
SEPARATE CONTROL
SOURCE.

CONTACTOR

"B"

CURRENT
TRANSFORMER

O.L.
RELAY

(WHEN USED,
SEE TABLE)

(IF USED)

LOAD

2 Pole 1 Phase Magnetic Contactors and Reversing Contactors


Single Phase ContactorsSize 00-312

Single Phase Reversing ContactorsSize 00134

166
Siemens Industrial Control Products

Wiring

Heavy Duty Control

Wiring

Class 83, 84
Duplex with Auto Alternation

Duplex with Relay Alternation

2
NEMA and HP
Rated Control

167
Siemens Industrial Control Products

Heavy Duty Control

Wiring

Class 83, 84
Duplex with Manual Alternation

Duplex with Lead Transfer Switch

NEMA and HP
Rated Control

168
Siemens Industrial Control Products

Reduced Voltage Pump Panels

Wiring

Class 87, 88
Elementary Diagram

Typical Available Options

2
NEMA and HP
Rated Control

Auto Transformer

Two Step Part Winding

169
Siemens Industrial Control Products

Reduced Voltage Pump Panels


Class 87, 88
Wye DeltaOpen Transition

Wye DeltaClosed Transition

NEMA and HP
Rated Control

170
Siemens Industrial Control Products

Wiring

S-ar putea să vă placă și