Sunteți pe pagina 1din 2

CALCULATIONSHEETFORMULTISTAGERESTRICTIONORIFICE

InputData:
StartupcirculationflowofP
6001
Operatingpressure
OperatingTemperature
Density
Viscosity
Numberoforificerequired
FirstOrificeInletpressure
PermanentPressureDropfor
multistageorifice
Nominalpipediameter
Insidepipediameter
Vaporpressureinoperating
Temperature
Criticalpressure
Criticaltemperature
Headlossinpipe
D6001maxoperatingpressure
Outletpressureoforifices

63.1
65
130
934.4
0.21
2
65

m3/hr
bar
C
kg/m3
cP
bar

60 bar
4 in
97.14 mm
2.7
220
374
1.5

bar
bar
bar
bar

2.9 bar
4.4 bar

Calculation:ASMEMFC3M_1989
C
l l ti
ASME MFC 3M 1989
F=criticalflowfactor=dp/(Inletpressurevaporpressure)shouldbelowerthan0.7
fortotaldp=60.7bar
>0.7thenmultistageorificeshouldbeselected
F=
0.963082
Fforfirstorifice=
0.690209 <0.7
Fforsecondorifice=
0.673575 <0.7
Fforthirdorifice=
0.634921 <0.7
Calculationforfirstorificedp=43bar

65to43
22to9
9to5

43
13
4

Calculationforsecondorificedp=13bar

Calculationforthirdorificedp=4bar

HeadLossCalculationinLineNo.4"BFW6005516F(H)
4inchesline
Totalmassflow
Density
Viscosity
PipeID
PipeRoughness
Flow
Velocity

58960
934.4
0.00021
0.0972
0.000046
63.09932
2.362108

kg/hr
kg/m3
Pa.s
m
m3/hr
m/s

Re
1021597
/d
0.000473
moodyfrictionfactor
0.017522
PipeLength
25 m
ElecationChange
15 m
HeadLoss
0.11748 bar
ElevationChangeheadloss(15m)
TotalHeadLossinpiping

1.37 bar
1.49 bar

S-ar putea să vă placă și