Sunteți pe pagina 1din 1

COMPANY NAME

PROJECT NAME
LOCATION
AREA

DATE:
Sheet No.:

SUN GAIN
/ TEMP. FACTOR
DIFF
SOLAR GAIN - GLASS

N
GLASS
NE
GLASS
E
GLASS
SE
GLASS
S
GLASS
SW
GLASS
W
GLASS
NW
GLASS
SKY LIGHT
WALL
WALL
WALL
WALL
WALL
WALL
WALL
WALL

=
=
=
=
=
=
=
=
=

0.0
0.0
0.0
0.0
0.0
0.0
6572.2
0.0
0.0

0
SQ. FT. x
12
x
0.36
0
SQ. FT. x
18
x
0.36
0
SQ. FT. x
26
x
0.36
0
SQ. FT. x
26
x
0.36
0
SQ. FT. x
24
x
0.36
0
SQ. FT. x
22
x
0.36
158
SQ. FT. x
20
x
0.36
0
SQ. FT. x
14
x
0.36
0
SQ. FT. x
40
x
0.42
0
SQ. FT. x
40
0.42
0
SQ. FT. x
40
0.42
0
SQ. FT. x
20
x
0.11
TRANS. GAIN -EXCEPT WALL & ROOF

=
=
=
=
=
=
=
=
=

0.0
0.0
0.0
0.0
0.0
0.0
619.2
0.0
0.0
0.0
0.0
0.0

1.10
0.46
0.42
0.42
1.08

=
=
=
=
=

1346.4
4344.2
1769.0
0.0
0.0

255

1785.0

3.41 x
1x
1x

1.25
3.41
3.41

=
=
=

2693.0
0.0
1364.0
20493.1
1024.7
21517.7
1075.9
148.0
1272.5
24014.1

72
SQ. FT. x
17
x
787
SQ. FT. x
12
x
351
SQ. FT. x
12
x
0
SQ. FT. x
12
x
0.00
CFM x
17
x
INTERNAL SENSIBLE HEAT
STANDING, WALKING
SLOWLY

LIGHTS(W)
APPLIANCES(W)
EQUIPMENT LOAD (W)
SUB TOTAL
SAFETY FACTOR
ROOM SENSIBLE HEAT
SUPPLY DUCT HEAT GAIN
OUTDOOR AIR
67
FAN H.P. HEAT GAIN
EFFECTIVE ROOM SENSIBLE HEAT

RM AREA (SQ. FT)


HEIGHT
FC HEIGHT
RM VOL. (CU. FT)
LIGHTING LOAD
OCCUPANCY (No.)
EQUIPMENT LOAD
CFM / PERSON
CFM/ SQMT
DAILY RANGE
CORRECTION FACTOR FOR DAILY RANGE
No. OF ROW (AHU / FCU)
COIL BY PASS FACTOR
FRESH AIR CHANGES / HR.
ROOM AIR CHANGES / HR.

632
0
400

17.0
1

x No.
x
x
x

x
x

0.12
1.0

x
x

5%
1.08
2545

=
=
=

VENTILATION

PEOPLE

0
STANDING, WALKING
SLOWLY

STEAM
APPLIANCES, ETC
ADDITIONAL HEAT GAIN
VAPOUR TRANS
SUB TOTAL
SAFETY FACTOR
ROOM LATENT HEAT
SUPPLY DUCT LEAKAGE LOSS

0
0

OUTDOOR AIR
67
EFFECTIVE ROOM LATENT HEAT

CFM

7
LBS/HR
LBS/HR

86

0.12

VOLUME

TONNAGE

4029

x
x

0.88
0.88

x No.
x No.

x
x

5.0
0.00

CFM/PERN
CFM/SQFT

x CU.FT

ACPH

DOOR TYPE
GLASS DOOR
EXHAUST FAN

AREA

FACTOR
4.5

QTY

USAGE
NO USE

TOTAL INFILTRATION AIR QUANTITY

35.0
0.0
35.0
67.2
67.2
cfm
0.0
0.0
0.0

APPARATUS DEWPOINT

EFFECTIVE ROOM SENSIBLE HEAT


----------------------------------------------------------------------------EFFECTIVE ROOM TOTAL HEAT

0.91

INDICATED ADP (F)


SELECTED ADP (F)

54.67
54.0

DEHUMIDIFIED AIR QUANTITY


TEMP. RISE

(1-BF) x (ROOM TEMP. - ADP TEMP)

DEHUMIDIFIED CFM

(EFFECTIVE ROOM SENSIBLE HEAT)


(1.08 x TEMP. RISE)

CFM AS PER MIN ACPH

4029

x CU.FT

16.72
1330

0.0

ACPH

SELECTED LPS

0.0
1330

RETURN AIR HEAT GAIN (ABOVE FALSE CEILING)


WALL
0
SQ. FT.
x
12

0.36

245

1715

NE

WALL

SQ. FT.

0.36

x
x

1080
1080
0
0

=
=
=
=

5.0%

E
SE
S
SW
W
NW

WALL
WALL
WALL
WALL
WALL
WALL

=
=

0
0
0
0
0
0
0
0
0
0

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

x
x
x
x
x
x
x

5.0%
0.68

0
0
0
0
1715
86
1801
90
471
2362

PARTITON
CEILING
ROOF (SUN)
ROOF (SHADED)

NOTES :
x
x

1.08
0.68

=
=

2.5%

SUB TOTAL

GRAND TOTAL HEAT, BTU/HR

DEG C
-

OUTDOOR AIR

SAFETY FACTOR

CU. FT
W / SQ. FT.
No.
W
CFM
CFM

26376

17.0
85.9

351.0
11.5
11.5
4029.5
1.8
7.0
400.0
5.00
0.00
8.0
4.0
0.12
1.0
0.0

EFFECTIVE ROOM TOTAL HEAT

SENSIBLE
67
CFM
LATENT
67
CFM
TOTAL OUTDOOR HEAT
R.A. HEAT GAIN (ABOVE F/C)

SQ. FT
FT

0.68

85.90 x
No.

SUMMER
APRIL & AUGUST
4PM

TOTAL VENTILATION AIR QUANTITY

LATENT HEAT
INFILTRATION

HUMIDITY
RATIO
GR/HR
153.90
68.00
85.90

OUTDOOR AIR

INFILTRATION

5.0%

82.00
-

%
71.5
55

SEASON
MONTH
TIME

PERSONS
7
SQMT
351
TOTAL AS PER ASHRAE 62.1

ESHF
7

RH

ROOM DATA

BTU/HR

0
SQ. FT. x
23
x
0.56
0
SQ. FT. x
12
x
0.56
0
SQ. FT. x
12
x
0.56
0
SQ. FT. x
12
x
0.56
0
SQ. FT. x
12
x
0.56
0
SQ. FT. x
85
x
0.56
72
SQ. FT. x 163 x
0.56
0
SQ. FT. x 138 x
0.56
0
SQ. FT. x 118 x
0.91
SOLAR & TRANS. GAIN - WALL & ROOF

ALL GLASS
PARTITION
CEILING
FLOOR
INFILTRATION

90.00
73.00
17.00

HEAT LOAD ESTIMATION FOR

AREA / QUATITY

N
NE
E
SE
S
SW
W
NW
ROOF (SUN) 1
ROOF (SUN) 2
ROOF (SUN) 3
ROOF (SHADED)

OUTDOOR (OA)
ROOM (RM)
DIFFERENCE

19-03-15

xxx
xxx
xxx

ITEM

PEOPLE

REV. : R0

WBT
deg.F

ADDRESS

COOL LOAD ESTIMATION


ESTIMATED BY
xxx
CHECKED BY
xxx

DBT

CONDITION

1085
3452
4537
0
30913
773
31686
2.64

STACK EFFECT NOT CONSIDERED

18

26
x
0.36
=
26
x
0.36
=
24
x
0.36
=
22
x
0.36
=
24
x
0.36
=
20
x
0.36
=
12
x
0.46
=
12
0.42
x
40
x
0.42
=
x
20
x
0.11
=
R. A. HEAT GAIN (ABOVE FALSE CEILING)

0
0
0
0
0
0
0
0
0
0
0

S-ar putea să vă placă și