Sunteți pe pagina 1din 16

Blue Solar charge controller MPPT

5
Module:
In series:
Total PV power:
Module temperature:
Controller:
System voltage:
Cable length, Module to MPPT *
* One way length
Max. input voltage
Max. PV voltage @ min. temperature
Min. input voltage @ MPP
Min. PV voltage @ max. temperature
Max. output current
Max. current @ MPP min. temp.
Max. current @ MPP max. temp.
Solar module configuration

17
3

Parallel:

4500 Wp
Min.

25
0 C

0
Max.

70 C

8
4
5m

Volt
Cross-section:

6.0 mm

150 V
143.5 V
49.0 V
85.5 V
85 A
85.0 A
* Power limiting @ low temp.
75.8 A
Accepted

Accepted NOT accepted


BHO 03-2015 1.9.1

Victron Energy SPM30-12 (SPM


Victron Energy SPM50-12 (SPM
Victron Energy SPM80-12 (SPM
Victron Energy SPM100-12 (SP
Victron Energy SPM130-12 (SP
Victron Energy SPM190-24 (SP
Victron Energy SPM300-24 (SP
Victron Energy SPP30-12 (SPP
Victron Energy SPP40-12 (SPP
Victron Energy SPP50-12 (SPP
Victron Energy SPP75-12 (SPP
Victron Energy SPP80-12 (SPP
Victron Energy SPP100-12 (SP
Victron Energy SPP140-12 (SP
Victron Energy SPP250-20 (SP
Victron Energy SPP280-24 (SP
Victron Energy SPP300-24 (SP
Custom: 1XYZ 1ABC
Custom: 2XYZ 2ABC
Custom: 3XYZ 3ABC
Custom: 4XYZ 4ABC
Custom: 5XYZ 5ABC
Custom: 6XYZ 6ABC
Custom: 7XYZ 7ABC
Custom: 8XYZ 8ABC
Custom: 9XYZ 9ABC
Custom: 10XYZ 10ABC

Manufacturer
[name]
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Custom: 1XYZ
Custom: 2XYZ
Custom: 3XYZ
Custom: 4XYZ
Custom: 5XYZ
Custom: 6XYZ
Custom: 7XYZ
Custom: 8XYZ
Custom: 9XYZ
Custom: 10XYZ

Type
[name]
SPM30-12
SPM50-12
SPM80-12
SPM100-12
SPM130-12
SPM190-24
SPM300-24
SPP30-12
SPP40-12
SPP50-12
SPP75-12
SPP80-12
SPP100-12
SPP140-12
SPP250-20
SPP280-24
SPP300-24
1ABC
2ABC
3ABC
4ABC
5ABC
6ABC
7ABC
8ABC
9ABC
10ABC

Coefficient support:
If you have the voltage temperature coefficient in mV/C, here is how to change it to %/C
Write the Voc value in Volt:
24.1
Write the coefficient value in mV/C:
-77
The coefficent value in %/C is now:
-0.320
If you have the current temperature coefficient in mA/C, here is how to change it to %/C
Write the Isc value in Ampere:
8.72
Write the coefficient value in mA/C:
4.7
The coefficent value in %/C is now:
0.054

nge it to %/C
V
mV/C
%/C

nge it to %/C
A
mA/C
%/C

Power
[W]
30
50
80
100
130
190
300
30
40
50
75
80
100
140
250
280
300
50
75
100
125
150
175
200
225
250
275

Vmpp
[V]
18
18
18
18
18
36
36
18
18
18
18
18
18
18
30
36
36
30.89
35.5
40.2
35.5
35.5
35.5
35.5
35.5
35.5
44.3

Impp
[A]
1.67
2.78
4.45
5.56
7.23
5.44
8.06
1.72
2.22
2.85
4.17
4.6
5.75
8.05
8.33
7.78
8.33
8.9
6.46
6.46
6.46
6.46
6.46
6.46
6.46
6.46
5.54

Voc
[V]
22.5
22.2
22.3
22.4
22.4
43.2
45.5
22.5
22.5
22.2
22.2
21.6
21.6
21.6
36.01
44.06
44.1
38.2
45
48
45
45
45
45
45
45
53

Isc
[A]
2
3.16
4.96
6.53
8.49
5.98
8.56
1.85
1.85
3.09
4.64
5.06
6.32
8.85
9.4
8.26
8.85
9.52
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
5.86

V temp coef
[%/C]
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.35
-0.35
-0.34
-0.34
-0.31
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.25

I temp coef
[%/C]
0.037
0.037
0.037
0.037
0.05
0.037
0.037
0.045
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.045
0.045
0.047
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.03

Art.Nr.
SPM010301200
SPM010501210
SPM010801210
SPM011001210
SPM011301210
SPM011902400
SPM013002400
SPP010301200
SPP020401200
SPP010501210
SPP020751200
SPP010801210
SPP011001210
SPP011401200
SPP022502400
SPP012802400
SPP023002400

Victron Energy BlueSolar MPPT 75/15


Victron Energy BlueSolar MPPT 75/50
Victron Energy BlueSolar MPPT 100/15
Victron Energy BlueSolar MPPT 100/30
Victron Energy BlueSolar MPPT 100/50
Victron Energy BlueSolar MPPT 150/35
Victron Energy BlueSolar MPPT 150/70
Victron Energy BlueSolar MPPT 150/85

Manufacturer
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy

Type
BlueSolar MPPT 75/15
BlueSolar MPPT 75/50
BlueSolar MPPT 100/15
BlueSolar MPPT 100/30
BlueSolar MPPT 100/50
BlueSolar MPPT 150/35
BlueSolar MPPT 150/70
BlueSolar MPPT 150/85

Power @ 12V Power @ 24V Power @ 36V


200
400
0
700
1400
0
200
400
0
440
880
0
700
1400
0
500
1000
1500
1000
2000
3000
1200
2400
3600

Power @ 48V Voc max Voc min Vmpp min


0
75
+5V
+1V
0
75
+5V
+1V
0
100
+5V
+1V
0
100
+5V
+1V
0
100
+5V
+1V
2000
150
+5V
+1V
4000
150
+7V
+2V
4850
150
+7V
+2V

12
12
12
12
12
12
12
12

System Voltage
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
36
48
24
36
48
24
36
48

Ibat max Efficiency@12 Efficiency@24 Efficiency@36 Efficiency@48


15
0.98
0.98
0
0
50
0.98
0.98
0
0
15
0.98
0.98
0
0
30
0.98
0.98
0
0
50
0.98
0.98
0
0
35
0.98
0.98
0.98
0.98
70
0.95
0.965
0.97
0.975
85
0.95
0.965
0.97
0.975

DATA:
Location:
Module info:

0 C min
70 C max
132.3 V Voc @25C
108.0 V Vmpp @25C
44.25 A Isc PV@25C
41.65 A Impp PV @25C
93.71 A Impp output @25C
-0.340 %/C Temp. Coeff. Voc
-0.450 V/C Temp. Coeff. Voc absolute
0.045 %/C Temp. Coeff. Isc
0.020 A/C Temp. Coeff. Isc absolute

Regulator info:

Voltage drop:

150.0 V Voc max


55.0 V Voc min
49.0 V Vmpp min
0.0178 Ohm/mm/m Cupper resistance
0.030 Factor

RESULTS:
Temperature
0 C
5
10
15
55
60
65
70 C

Voc max.
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V

Voc START min.


55.0 V
55.0 V
55.0 V
55.0 V
55.0 V
55.0 V
55.0 V
55.0 V

Temperature
0 C
5
10
15
55
60
65
70 C

Ibat max.
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A

Impp PV max.
41.15 A
41.25 A
41.35 A
41.45 A
42.25 A
42.35 A
42.45 A
42.55 A

c absolute

85.0 A Ibat max


48 V System voltage
0.975 Max. Efficiency

(Col 18 )

Vmpp RUN min.


49.0 V
49.0 V
49.0 V
49.0 V
49.0 V
49.0 V
49.0 V
49.0 V

String Voc max.


143.5 V
141.3 V
139.0 V
136.8 V

String Vmpp max.


119.2 V
117.0 V
114.7 V
112.5 V

System Voltage
48 V
48 V
48 V
48 V
48 V
48 V
48 V
48 V

Ibat max. @ Impp


85.00 A
85.00 A
85.00 A
85.00 A

Ibat min. @ Impp

81.10
79.36
77.60
75.84

A
A
A
A

String Vmpp corr.max.


116.7
114.5
112.2
110.0

String Voc min.

118.8
116.6
114.3
112.1

V
V
V
V

String Vmpp min.

94.5
92.3
90.0
87.8

V
V
V
V

String Vmpp corr. min.

92.1
89.9
87.7
85.5

V
V
V
V

History
1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 -

Added new solar modules, and now 10 additional modules can be added instead of 3.
Added a small calculation on the 'Modules' TAB to help when temperature coefficiences a
Added new solar modules, voltage drop correction and an option to rise the cell temperat
Inserted 4 new regulators and 2 more custom module.
Inserted 4 languages @ updated not applicable (N.A.) voltages for 75/15, 75/50 & 100/15
Changed texts and Module temperature window.
Power reduction comment set @ highest temperature.
Reduced output current to maximum output current at low & high temperatures. Now a s
Inserted BlueSolar MPPT 100/15
Inserted custom module
First version

can be added instead of 3.


en temperature coefficiences are not in %/C or %/K but in mV/C or mA/C
option to rise the cell temperature in the example list, when the solar modules do not see snow and therefor tem

ages for 75/15, 75/50 & 100/15.

& high temperatures. Now a system will show 'power loss' only wenn the output current exceeds the max. at lo

not see snow and therefor temperatures will not be so low.

current exceeds the max. at low & high temperatures.

S-ar putea să vă placă și