Sunteți pe pagina 1din 1

Exterior Wall

FLEXIBLE NATURAL
GAS
LINE TO ISLAND
APPLIANCE

Island
Counter

Gas Pipe From Above


Rigid or CSST

Sealed to Sleeve
and Gas Pipe

Access Door

Connector
Sealed to Sleeve and Gas Pipe
Flex connection to Rigid Gas
Pipe at Access Door

Concrete Floor

Vent to Outside
Flexible Gas Pipe
Wardflex or Equal

ABS or PVC Sleeve, min. 1/2 inch Larger than Gas Pipe

Exterior Wall
Seal

Seal

Overhead Gas
Line to Meter

RIGID NATURAL
GAS
LINE TO ISLAND
APPLIANCE

Vented Access
Panel for Removal
of Gas Line

Watertight Cap

Sleeve to Exterior

ABS or PVC Sleeve, min. 1/2 inch Larger than Gas Pipe

SLAB CHASES
FOR
NATURAL GAS
PIPING

Pipe to
Conduit Seal

A. Provide channel or recess


in slab. Use removable cover
plate.
B. Pipe in conduit sealed at
floor line, with vent outside.

A
Vent

Seal

UPC 1211.4 No gas piping shall be installed in or on the ground


under any building or structure unless installed in gastight
conduit, and all exposed gas piping shall be kept at least six (6)
inches above grade or structure. The term "building or structure"
shall include structures such as porches and steps, whether
covered or uncovered, breezeways, roofed porte-cocheres,
roofed patios, carports, covered walks, covered driveways and
similar structures or appurtenances.

ABS or PVC sleeve, min 1/2 inch larger than gas pipe

Gas Under Slab Installation


(951) 304-2489 26442 Beckman Ct, Murrieta, CA. 92562
Fax (951) 461-6097

10/5/05

1 of 1