Sunteți pe pagina 1din 3

Breeze

Overall Free Length, L_0 =

0.827

Installed Compressed Length, L_1 =

0.587

Working Compressed Length, L_2 =

0.488

Nom. wire diameter, d or thickness, t =

0.012

Outer diameter, O.D. =

0.118

Number of total coils is =

20.000

Number of active coils is =

18.000

The inside diameter, I.D. =

0.094

Solid Height, L_solid =

0.248

Deflection @ L_1, _1=

0.240

Deflection @ L_2, _2=

0.339

Working deflection, w =

0.098

Spring Constant, K =

1.294

Load @ L_1 =

0.311

Load @ L_2 =

0.438

Load @ Solid Height, P_solid =

0.749

Stress @ L_1, S_min =

59324.802

Stress @ L_2, S_max =

83638.245

Stress range, S_r =

12156.722

Estimated fatigue life, N =

195689794.075

Stress at Solid height =

142963.047

Spring constant is lower


Load at Installed length is lower tha
Load at working length is lower tha
Stress at L1 is higher than the
Stress at L2 is higher than the
Estim

AC

Q2

1.051

0.620

0.913

0.589

0.815

0.541

0.016

0.020

0.118

0.120

37.700

17.500

35.700

15.500

0.087

0.080

0.609

0.345

0.138

0.031

0.236

0.079

0.098

0.047

2.309

14.839

0.318

0.467

0.545

1.168

1.020

4.081

26140.371

19495.733

44812.064

48739.332

9335.847

14621.799

9263232920.264

878748649578.818

83798.560

170222.116

Spring constant is lower than Q2 and AC


Load at Installed length is lower than lowest load by 25%
Load at working length is lower than lowest load by 1%
Stress at L1 is higher than the highest stress by 126.00%
Stress at L2 is higher than the lowest stress by 86.60%
Estimated fatigue life 195689794.075

(inches)
(inches)
(inches)
(inches)
(inches)
(dmls)
(dmls)
(inches)
(inches)
(inches)
(inches)
(inches)
(lbf / in)
(lbf)
(lbf)
(lbf)
(lbf / in2)
(lbf / in2)
(lbf / in2)
(lbf / in2)

0.2450399389
0.0099285959
1.2694705619
0.8664225113

S-ar putea să vă placă și