Sunteți pe pagina 1din 1

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

POP-UP FLOOR RECEPTACLE

GENERAL NOTES:

LEGEND AND SYMBOLS:

1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE


WITH THE PROVISION OF THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES
OF THE LOCAL CODE ENFORCING AUTHORITIES AND THE
REQUIREMENTS OF THE LOCAL POWER COMPANY.

FINISH FLOOR LINE

C.O/TEL OUTLET

CIRCUIT RUN CONCEALED IN WALL OR CEILING

LO

LIGHTING OUTLET

CO

CONVENIENCE OUTLET

CIRCUIT RUN CONCEALED IN CONCRETE SLAB


TEF

TOILET EXHAUST FAN

EWH

ELECTRIC WATER HEATER

WP

WEATHER PROOF

FCU

FAN COIL UNIT

ACCU

AIR COOLED CONDENSING UNIT

LP - 1 HOMERUN TO PANELBOARD

2. THE CONTRACTOR SHALL SECURE ALL PERMITS AND PAY


ALL FEES REQUIRED FOR THE WORK AND SHALL FURNISH THE
OWNER THROUGH THE ENGINEERS. FINAL CERTIFICATES OF
ELECTRICAL INSPECTION AND APPROVAL FROM PROPER
GOVERNMENT AUTHORITIES FOR COMPLETE WORK.

SURFACE MOUNTED LIGHTS, (BY ARCHITECTS'S SPECS


50W, HALOGEN LIGHTS, (BY ARCHITECT'S SPECS)
18W, PIN LIGHTS, (BY ARCHITECT'S SPECS)

4. ALL METALLIC CONDUITS, CABINETS AND EQUIPMENT SHALL


BE PROPERLY GROUNDED AND BONDED BY MEANS OF
COPPER STRAPS. CONNECTION TO GROUND ROD SHALL BE
RIGID STEEL CONDUIT. CONDUIT PIPES EMBEDDED IN DIRECT
CONTRACT WITH THE SOIL BE COATED WITH ASPHALT PAINT
WRAPPED IN ASPHALT TAPE, AND FINALLY ANOTHER COAT OF
ASPHALT PAINT, EXCEPT AS OTHERWISE NOTED.

RECESSED PINLIGHT, (BY ARCHITECT'S SPECS)

WALL MOUNTED LIGHTING FIXTURE, SCONCE

SINGLE GANG SWITCH, 10A, 230V WITH PLATE


TWO GANG SWITCH, 10A, 230V WITH PLATE
NOTE: LETTER DENOTES LIGHT CONTROLLED

3Sabc

3
EE-1

POP-UP FLOOR RECEPTACLE


SCALE

2
EE-1

NTS

GROUND ROD DETAIL


SCALE

KILO-WATT-HOUR METER WITH


CURRENT TRANFORMER
SERVICE ENTRANCE

OR

TWO GANG SWITCH, 15A, 230V WITH PLATE


NOTE: LETTER DENOTES LIGHT CONTROLLED

BRASS SCREW ON PLUG COVER


W/NEOPRENE GASKET

MOLDED CASE CIRCUIT BREAKER,


RATING AS INDICATED

20 AT,2P

CHIME, 230V 60Hz

2Sab

COPPER WELD

LP- LIGHTING PANEL


PP- POWER PANEL
ATS- AUTOMATIC TRANSFER SWITCH
MCB- MAIN CIRCUIT BREAKER

CEILING ELECTRIC FAN

SECTION

JUNCTION BOX

TEF

TOILET EXHAUST FAN (PROVISION)

EWH

ELECTRIC WATER HEATER (PROVISION)

CAPB

CATV PULLBOX, 300(L)x300(W)x100(D),GA.16

TIC

TELEPHONE TERMINAL CABINET

PLAN
FINISH FLOOR LINE

NEOPRENE GASKET

WATER SEALANT COMPOUND


CONDUIT PROVISION
FOR GROUND CONNECTION
SIZE AS SHOWN

GROUND CLAMP

GROUND WIRE 50s.q.m


BARE COPPER STRANDED
3M THK. MAT FOUNDATION
COPPER WELD

FLOOR MOUNTED VOICE & DATA OUTLET


S3W

9. PULLBOXES SHALL BE PROVIDED BY THE CONTRACTOR


WHENEVER NECESSARY. TO FACILITATE WIRE PULLING EVEN
IF WHERE NOT INDICATED ON THE PLANS.

2S3Wab

10. ELECTRICAL DEVICES AND MATERIALS SHALL BE


MANUFACTURED BY THE FOLLOWING.

WALL MOUNTED VOICE & DATA OUTLET


t

THREE GANG THREE WAYS SWITCH


NOTE: LETTER DENOTES LIGHT CONTROLLED

SECTION

VOICE & DATA CRICUIT RUN

"4t"- FOUR RUNS OF NUMBER 22/3C AWG PVS

DUPLEX CONVENIENCE OUTLET 15A, 230V PARALLEL


BLADES GROUNDING TYPE
C-COUNTER TOP OUTLET, 150MM A.C.
REF

2. CIRCUIT BREAKERS/DISCONNECT SWITCHES---- SQUARE D, G.E.


3. CONDUITS & FITTINGS (EACH TYPE)------------------ MATSUSHITA

TWO GANG THREE WAYS SWITCH


NOTE: LETTER DENOTES LIGHT CONTROLLED

COPPER WELD

"2t"- TWO RUNS OF NUMBER 22/3C AWG PVS


3S3Wabc

1. RECEPTACLES & SWITCHES ----------------------------- NATIONAL

THREE WAYS SWITCH

WM

4. DEVICE PLATES --------------------------------------------- NATIONAL

"6t"- FIVE RUNS OF NUMBER 22/3C AWG PVS

REFRIGERATOR SINGLE OUTLET 15A, 250V GROUNDING


TYPE UNIVERSAL OUTLET

ELECTRIC MOTOR
MOTOR CONTROLLER

WASHING MACHINE SINGLE OUTLET 20V, 250V


GROUNDING TYPE, UNIVERSAL OUTLET WEATHER
PROOF TYPE

MOUNTING HEIGHTS:

DRYER
DR

RANGE OUTLET, 50A, 250V, GROUND TYPE, NEMA 10-50R

5. CATV OUTLETS ---------------------------------------------- NATIONAL

1.

1.37M (4'-6") FROM CENTER OF DEVICE


TO FINISH FLOOR LINE.

RANGEHOOD

6. TELEPHONE OUTLETS ------------------------------------ NATIONAL


RH

7. INSULATED CONDUCTOR -------------------------------- PHILFLEX, COLUMBIA

SINGLE OUTLET 15A, 230V PARALLEL BLADES


GROUNDING TYPE, FLOOR MOUNTED (POP-UP)

8. HANGERS & SUPPORTS ---------------------------------- ERICO-CADDY

GROUND WELL

2.

XLVI

10. KILOWATT-HOUR-METER ------------------------------ FUJI, OMRON, G.E.


G

11. POWER & AUXILIARY SERVICE BOXES SHALL BE CONCRETE


PSB

PIPE TO CONNECTED TO NEAREST DRAINER LINE.


ASB

EXTRA LOW VOLTAGE TRANSFORMER


GENERATOR SET
POWER SERVICE BOX
500MM X 500MM X 500MM (D)
IN CONCRETE

CONVENIENCE & TEL OUTLET:


0.30M (1'-0") FROM CENTER OF PLATE
TO FINISH FLOOR LINE OR 0.15M(6")
ABOVE WORKING COUNTER OF FITTED
INTO BASEBOARD IF REQUIRED BY THE
ARCHITECT.

GROUND ROD

9. UTILITY & JUNCTION BOXES --------------------------- COUSEHINDS,FUMACO

LIGHT CONTROL SWITCHES:

2.

PANEL BOARD:
1.37M (4'-6") FROM CENTER OF PANEL
TO FINISH FLOOR LINE UNLESS
OTHERWISE REQUIRED BY THE FEILD
CONDITIONS.

AUXILIARY SERVICE BOX


400MM X 400MM X 500MM (D)
IN CONCRETE

THIS DRAWING IS THE PROPERTY OF THE ARCHITECT AND CAN NOT BE REPRODUCED WITHOUT PROPER CONSENT. IT IS AN

DESIGN SHOULD BE NOTIFIED BY THE USER.

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

8. ALL RECEPTACLE OUTLETS SHALL BE PROPERLY


GROUNDED TO THE BOX BY MEANS OF GROUNDING LUGS.

PANEL BOARD

1 X 36W FLUORESCENT LIGHTING FIXTURE RECESSED


MOUNTED INDUSTRIAL LIGHT

PUSH BUTTON SWITCH FOR CRIME, WEATHERPROOF

COPPER WELD

SQUARE BOX

RESIDUAL CURRENT CIRCUIT BREAKER

1 X 36W FLUORESCENT LIGHTING FIXTURE SURFACE


MOUNTED INDUSTRIAL LIGHT

20mm COUPLING,
SILICON ALUMINIUM
BRONZE

CABLE TV OUTLET
NOTE: USE 1RG59 COAX CABLE

7. EXPOSED CONDUIT RUNS SHALL BE INSTALLED PARALLEL


OR PERPENDICULAR WITH THE BUILDING LINE AND
SUPPORTED BY CONDUIT CLAMPS EVERY 1.5M DIAGONAL
CONDUIT RUNS SHALL NOT BE ACCEPTED.

15mm C

1
EE-1

GROUND ROD DETAIL


SCALE

NTS

NTS

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

UPLIGHT, (BY ARCHITECT'S SPECS)

BARE COPPER STRANDED


3M THK. MAT FOUNDATION

BOX

MAIN CIRCUIT BREAKER

MCB

PENDANT LIGHTS, (BY ARCHITECT'S SPECS)

3. ALL MATERIALS TO BE USED SHALL BE NEW AND INSTALLED


IN APPLICATIONS FOR WHICH THEY ARE INTENDED.

GROUND CLAMP