Documente Academic
Documente Profesional
Documente Cultură
Introduction
The objective of this project is to check the strength of vertical ladder due to step load
load..
The loads on the vertical ladder is at three rung locations each 5.0KN summing it to 15
15..0KN
KN..
FE analysis is performed to check if the vertical ladder can take the above load
load..
SACS (offshore structural software) software is used in the present analysis
analysis..
AISC 13th Edition code is used in the strength analysis
analysis..
-2-
Material properties
Component
Material
name
Yield strength
(MPa)
Poisons
ratio
Allowable
criteria / code
Allowable UC
factor
Lifting beam
SS400
235MPa
0.3
1.0
Max UC = 0.36
5KN
5KN
5KN
CONFIDENTIAL
-3-
Analysis Results
Max UC = 0.36
-4-
Conclusions
The present analysis is performed to check the strength of the vertical ladder
ladder..
The max unity check factor is found to be 0.36
36,, which is less than the allowable i.e.1.0
Thus it can be said that the vertical ladder has sufficient strength in the present
working conditions.
conditions.
CONFIDENTIAL
-5-