ATER CONFIGURATION FAILURE.

1st step: alarma apare in FO CORE: MGW02 - ATER CONFIGURATION FAILURE.


2nd step: detaliile necesare pentru investigatie in partea de RAN (vin de la FO CORE sau
BO CORE)
Please check BSC's Ater configuration (circuit type, pool, and codec) on BSC ZH9924 (SPC 11AE) for
APCM 14545, 14662, 14822
14545 - 19 4043
14662 - 10 4074
14822 - 23 4137

13
19
22

6
4
6

16
16
16

28
28
28

EFR&DR&AMR&D144
EFR&DR&AMR&D144
EFR&DR&AMR&D144

14545 - CCSPCM=45 TSL=19


14662 - CCSPCM=2 TSL=10
14822 - CCSPCM=86 TSL=23
14545: MSC number = MSS01
14662: MSC number = MSS03
14822: MSC number = MSS02

3rd step: te conectezi pe BSC-ul subliniat de Core cu MML (puty sau hit)
4th step: printezi toate SPC-urile:
NVI:NA0,:;
FlexiBSC BSCZH9924

2013-05-08 15:46:18

SIGNALLING ROUTE STATES


DESTINATION:
SP
RS ROUTES:
NET SP CODE H/D
NAME
STATE SP CODE H/D
STATE PRIO
--- ------------------ ---------------- ----- ------------------ ------- ---NA0 088B/02187
MSS01
AV 088B/02187
AV-EX 7
NA0 088C/02188

MSS03

AV

088C/02188

AV-EX 7

NA0 108B/04235

MSS02

AV

108B/04235

AV-EX 7

NA0 11AE/04526

BZH24

OWN SP AS SEP

COMMAND EXECUTED

5th step: printezi ETPCM-ul echivalent in BSC. Pentru asta ai nevoie de:

a. SPC-ul MMSS-ului
b. CCSPCM
c. TSL
RCI:SEA=7:NET=NA0,SPC=088B,CCSPCM=45,TSL=19:;
FlexiBSC BSCZH9924

2013-05-08 15:59:36

CGR : 10
NCGR : MSS12V
ETPCM-TCPCM-TSL : 75-2-19
ORD : 1370
CTRL : Y
LSI
: AINA0
HGR : 1-1370
STATE : WO-EX
NET : NA0 SPC(H/D) : 088B/02187
CCSPCM : 45
COMMAND EXECUTED

6th step: printezi statusul si configuratia lui


USI:ET,75::;
EXECUTION STARTED
FlexiBSC BSCZH9924

2013-05-08 16:03:44

WORKING STATE OF UNITS


UNIT
PHYS STATE LOCATION
ET-75
WO-EX SET-0
BCSU-4

INFO
-

WGO:75:ALL:;
EXECUTION STARTED
ET_PCM

75

TC_PCM POOL
TYPE ET_PCM_TSLS
1 28
AMR&EFR&DR&D144
1 && 8
2 28
AMR&EFR&DR&D144
9 && 16
3 28
AMR&EFR&DR&D144 17 && 24
4 28
AMR&EFR&DR&D144 25 && 31
THROUGH CONNECTIONS
-

COMMAND EXECUTED