Weight of

contents

Stirrer Delay Period

Stirrer Delay Finish Beater ON

Discharge Valve Delay Period

Discharge Valve Delay Finish Discharge Valve, Pump, Bypass Valve ON

500 Kg

Batch
Weight
Range

Delay 02
400 Kg
320 Kg

Batch weight
Maximum limit

Delay 01

300 Kg
Level 2
250 Kg

Level 02

Level 1

Level 01

20 Kg

Batch weight
Minimum limit

0
Add material
01 Signal

3
4:30
Beater ON Dis. Valve ON

Material 1 ACK
Pressed,
Delay 01
Starts

6
Delay 01
Finishes

9
7:30
Beater ON Dis. Valve ON

Material 2 ACK
Pressed,
Delay 02
Add Material
Starts
02 Signal

14
Delay 2
Finishes.
Batch Ready
Signal ON

time