The present paper aims to determine the dioxine concentration in gaseous emissions sampled from
incinerator and also the contamination level of a soil surface with dioxine, by using for this the extraction
method of the molecular ion m/z = 322 from standard chromatogram of dioxine 2,3,7,8- tetrachlorodibenzop dioxine. The method represents the process of dioxine chromatogram labeled with 13C12 and its mass
spectrum data that do not exist in spectral library. A comparison of mass spectra of the standard dioxine
sample and the analyzed sample has been performed based on the extraction method. This method provides
an optimal efficiency in the identification and determination of dioxine concentration in traces, as it has
been experimentally demonstrated in the sample taken in Dobrogea aria from an incinerator, having a
dioxine concentration below 1 ng/m3.
Keywords: 2,3,7,8 tetrachlorodibenzo p dioxina; 2,3,4,7,8 pentachlordibenzofuran (PeCDF); 1,2,3,7,8,9
hexachlordibenzofuran (HxCDF); 1,2,3,4,6,7,8heptachlordibenzofuran (HpCDF)
* email: aditubors@yahoo.com
REV. CHIM. (Bucureti) 58 Nr. 2 2007
151
152
Parametrii de lucru
Volumul minim de gaz prelevat este de 4 m3/h (pentru a
atinge limita de detecie).
Timpul minim de prelevare este 6 h, iar cel maxim 8h.
Marcarea liniei de prelevare se face cu 13C12 (masele
standardelor adugate sunt 400 pg pentru PeCDF i HxCDF
i 800 pg pentru HpCDF, fiecare pe o baz de 10 m3 de
volum de gaz (gaz uscat) i pentru a msura concentraia
de 0,1 ng I-TEQ/m3; soluia standard de prelevare conine
4% tetradecan ca antioxidant i trebuie s aib un volum
de cel puin 100 l.
Fatorul echivalent toxic internaional (I-TEF) stabilit
pentru 2,3,7,8-TCDD este 1.
Prelucrarea probelor
Extracia este prima operaiune pentru a izola PCDD/
PCDF din prob i a-i colecta ntr-un solvent de un volum
corespunztor.
Procedurile de extracie folosite n aceste experimente
sunt bazate pe extracia soxhlet a filtranilor i
adsorbanilor i pe extracia lichid a produilor de
condensare.
Purificarea probelor colectate pentru acest studiu s-a
realizat prin tehnica de cromatografie n multi -coloane,
utiliznd un ir de adsorbani, urmrindu-se astfel
ndeprtarea componenilor matriceali din proba primar
extras care pot suprancrca metoda de separare,
perturb cuantificarea sau au un impact asupra
performanei metodei de identificare i cuantificare.
Purificarea are ca rezultat o mbogire cu substanele de
analizat n proba final.
Pentru a realiza o limit de detecie bun, extractul de
prob purificat a fost concentrat la un volum de 50 mL.
Aparatura de analiz
Aparatura pe care s-au executat analizele este cuplajul
gaz-cromatograf spectrometru de mas, tip Varian Saturn
3900/2100T. Gaz cromatograful este echipat cu injector
split-splitless, coloan capilar Factor Four VF-5 ms, cu di
= 0,25 mm, L = 30 m, film faz staionar = 0,25 m.
Regimul de temperatur al coloanei 60 (1min) - 15oC/
min 300 (13min)
Temperatura injectorului = 250oC
Gaz purttor Heliu calitate 6.0 (ultrapur)
ntrzierea de pornire (sd) = 3 min.
Splitare 2 mL/min. pn la 4 minute apoi 25 mL/min.
Spectrometrul de mas are detector trap ionic cu o
sensibilitate de 10 pg HCB (hexaclorbenzen).
Rezultate i discuii
Identificarea poluanilor organici clorurai persisteni,
respectiv dioxine i furani, se realizeaz folosind gazcromatografia cuplat cu spectrometria de mas (GC-MS)
prin scanare MS de rezoluie nalt folosind tehnica
impactului cu electroni (EI). Prezena i concentraiile
izomerilor specifici, cum este 2,3,7,8 - TCDD, pot fi
determinate din rapoartele anumitor fragmente de mas.
Nivelul de emisie al PCDD/PCDF provenite de la surse
fixe (incinerator) este de aproximativ 0,1 ng I-TEQ/m3 i o
concentraie n pulberi de la 1 pn la 15 mg/m3.
Legislaia impune ca PCDD/PCDF s nu depeasc
0,1 ng I- TEQ/m3; n mediu, PCDD/PCDF apar ca un amestec
complex asociat cu ali compui nrudii structural, cum
ar fi PCB.
Determinarea de PCDD/PCDF se bazeaz pe
cuantificarea prin tehnica diluiei izotopice, folosind GS/
MS. Izomerii 2,3,7,8 clor PCDD/PCDF cu carbon marcat 13C12
REV. CHIM. (Bucureti) 58 Nr. 2 2007
Sample ID:
DIOX_ST0
Scan ES+
322
1.29e4
RT
BasePeak
22.904
322
100
13.185
281
18.334
281
15.154
355
19.695
355
16.862
429
20.937
429
23.241
355
22.123
429
0
DIOX_ST0
100
15.154
355
Scan ES+
TIC
9.18e6
RT
BasePeak
16.845
429
19.711
355
18.334
281
20.953
429
13.185
281
22.090
429
23.177
355
24.192
25.194 26.131
355
429
355
rt
12.000
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
Scan ES+
1.15e4
322
100
320
324
%
257
259
194
97
261
74
50
109 113
49
159161
85
99 115124
606162
134 158 162
44
84 96
54
38
69
31
0
20
40
285
287
196
60
80
100
120
140
160
193
187
180
326
229231 250
207
235
217
200
220
240
Sample ID
269
260
289
280
319
313
300
320
340
360
380
Acquired on 27-Feb-2004 a
DIOXINAC
22.954
44
100
Scan ES
332
583
RT
BasePea
%
23.064
44
12.940
57
23.742
21.165
22.513 23.111
44 44
13.913
17.810
19.805
20.84644 22.022 44
18.577
16.855
14.769 15.72516.362
17.427
19.502
57
57
57 57
44
44
57
57
57
57
44
57
0
DIOXINAC
Scan ES
TIC
2.03e5
RT
BasePea
13.834
57
100
12.613
57
17.174
239
13.300
57
14.292
127
16.728
239
15.868
15.549
57 57
22.875
18.961
21.67322.038 57
19.455
21.14997 57
17.363 18.577 149
97 20.236 57
57
119
57
21
23.679
57
rt
14.000
16.000
18.000
20.000
22.000
153
Scan ES+
611
334
100
332
336
270
149
89
204
57
102
65
80
71
88 91
206
166
97
70
54
115
103
189
120
135
110
137
144
150
171
162
173
208
200
212
194
331
272
219
241
227 231
243
267
262
283
279
297
299
301
338
307
323
339
355363
288
365
m/z
60
80
100
120
140
160
180
200
220
240
260
280
300
320
340
360
154
156
Concluzii
Pentru determinarea concentraiei de dioxin n probele
prelevate, precum i pentru determinarea nivelului de
contaminare al unei suprafee de sol cu dioxin s-a utilizat
metoda extraciei ionului de fragmentare m/z = 322 din
cromatogram pentru 2,3,7,8, tetracloro-dibenzo-p-dioxin.
Studiul comparativ al spectrelor de mas privind proba
de dioxin etalon i cea a probei prelevate DIOXIN,
confirm lipsa dioxinei din proba prelevat prin extracie
n toluen de la un incinerator din zona Dobrogea.
Experimentele efectuate asupra probei DIOXIN
prelevat din alt locaie a aceleiai zone (zona Dobrogea)
arat o concentraie de dioxin de 0,1265 ng/m3.
Metoda dovedete astfel eficien optim pentru
determinarea concentraiei de dioxin n urme, gsinduse c n proba DIOXIN concentraia de dioxin este sub
1ng/m3.
Bibliografie
1.JAN-AKE GUSTAFSSON, MAGNUS INGELMAN-SUNDBERG,
Biochemical Pharmacology, 28, 1979, p. 497
2. GREIG, J.B., JONES, G., BUTLER, W.H. , BARNES, J.M., MRC
Toxicology Unit, Medical Research Council Laboratories, England, Food
and Cosmetics Toxicology, 11, 1973, p. 585
3. SBRANA I., D. RUSCIANO, D. LASCIALFARI, T. LARI , N. LOPRIENO,
Mutation Research/Environmental Mutagenesis and Related Subjects,
85, 1981, p. 278
4. KROWKE, R., Chemosphere, 15, 1986, p. 2011
5.HASELGROVE, T.D., JEVRIC, M., TAYLOR, D.K., TIEKINK, E.R.T.,
Tetrahedron, 55,1999, p.14739
6. J.C. MAURIN, F. BLEICHER, H. MAGLOIRE, Archives de Pdiatrie,
12, 2005, p.1636
7. LE THI NHAM TUYET, ANNIKA JOHANSSON, Reproductive Health
Matters, 9, 2001, p. 156-164
8.COSTOPOULOU,D.,VASSILIADOU,I.,PAPADOPOULOS,
A .,
MAKROPOULOS, V., LEONDIADIS,L., Report Dioxin Analysis
Laboratory, 2005
9. KORFMACHER,W.A., HANSEN, E. B. JR., KENNETH L. ROWLAND,
The Science of The Total Environment, 57, 1986, p. 257
10. ARSTIL. A. U. . REGGIANI, A, G, SORVARI,T. E. , RISNEN , S.,
WIPF, H. K., Toxicology Letters, 9, 1981, p. 215
REV. CHIM. (Bucureti) 58 Nr. 2 2007