Sunteți pe pagina 1din 1

4 3 2 1

WELL WATER
Pressure: 6 bar, stabilized
regeneration Flow max: 43 m³/h (required!)
flow min 4 bar Chemical Dosing Flow avrg: 30 m³/h (3 x 10)
23 m3/h KMnO4
Fe: 1,5 mg/l, Mn: 0,6 mg/l
D D
MANGANESE
GREENSAND
FILTRATION

FILTER 1 FILTER 2 FILTER 3

C C
iNTERMEDIATE filtrate discard
BUFFER TANK max. flow
(design stage) 30 m3/h
Size XX m3

NF make up Chemical Dosing


CONSUMER Anti Scalent
max. flow
RO constant 12 m3/h
12,5 m3/h
Backwash
max. flow
BOOSTER UNIT 23 m3/h
RO make up
Capacity 12m3/h @ 4 bar
NF Units
Net Capacity
B Softener 2 x 5m3/h B
CONSUMER concentrate
Net Capacity max. flow
Laundry
1 x 5m3/h 2,5 m3/h
variable, intermitted

DRAIN, DN 200
BOOSTER UNIT
washing maschine
Capacity 5 m3/h @ 3bar
frequency converter operated CONSUMER
- Boiler regular 6,5 m3/h,
BOOSTER UNIT variable, intermitted
Boiler make up - Boiler emergency
Capacity 10 m3/h @ 3bar (irregular) max 10 m3/h
frequency converter operated - Laundry max 3,5 m3/h

A A
Flow Scheme Treatment Train, Option B
Boiler Water Pretreatment
SIZE DATE DWG NO REV

22/06/2009 SG-013-DWG-RS-09-002 rev0.vsd 0


NALCO GLOBAL EQUIPMENT
SOLUTIONS EUROPE SCALE none S Gaulinger SHEET 1 OF 1

4 3 2 1