Sunteți pe pagina 1din 1

Formulario

FORMULA PARA CALCULAR LA VELOCIDAD ANULAR (VA) EN


PIE /MIN).
VA = (24.51 X Q) / (D2 d2)
DONDE:
24.51 = CONSTANTE
Q = GASTO EN GAL/MIN
D = DIAMETRO DE BNA. O AGUJERO
d = DIAMETRO EXTERIOR DE TP

FORMULA PARA CALCULAR LA VELOCIDAD ANULAR PTIMA


(VAO) EN PIE/MIN.
VAO = 1416 / (DF X DA)
DONDE:
1416 = CONSTANTE
VAO = VELOCIDAD ANULAR
DF = DENSIDAD DE FLUIDO
DA = DIAMETRO DEL AGUJERO

PASO No. 4

CALCULAR LA CAIDA DE PRESION EN LAS


TOBERAS
P = DENSIDAD X Q2 / 10858 X (rea toberas)2
DONDE :
P = CIADAD DE PRESION EN TOBERAS EN PSI
DENSIDAD EN LB / GAL
Q = GASTO DE LA BOMBA EN GAL / MIN
10858 = CONSTANTE

P = 12 .83 LB / GAL X (700 GAL)2 / 10858 X


(0.518 )2
CAIDA DE PRESION EN EL INTERIR DE LA SARTA
Lb/pg2

EJEMPLO: VAO = 1416 / (1.25 GR/ CC X 5.875 PG)

FORMULA PARA CALCULAR EL TIEMPO DE ATRASO


UTILIZANDO LA VELOCIDAD ANULAR.

PTP:

( vp .18d .82Q1.82 )
700.3

TIEMPO ATRASO = PROFUNDIDAD EN PIES / VA

(Vp) Viscosidad plstica

FORMULA PARA CALCULAR EL INDICE DE ENERGIA


HIDRAULICA (INDICE DE LIMPIEZA)

(d) .-Densidad gr/cc

IEHP = (P X Q) / 1714 X AREAagujero

IEHP = (2158 PSI X 700 GAL / MIN) 1714 X


240.5
DONDE:
IEHP = INDICE DE ENERGIA HIDRAULICA
P = CAIDA DE PRESION EN LAS TOBERAS
Q = GASTO DE EN GAL/MIN
1714 = CONSTANTE
H.P. CABALLOS DE FUERZA
PASO No. 1
CALCULAR EL AREA DE TOBERAS
Atoleras (PG 2)= 0.7854 x (D )2 X No. DE TOBERAS
SUSTITUYENDO LOS VALORES EN LA FORMULA

(D).- Dimetro interior de la tubera en pulgadas


(l) Longitud de la tubera.
Espacio anular

DaDt

700.3
( vp.18d .82Q1.82l )

Da Dimetro de agujero o interior de la TR

PASO No. 2
CALCULAR EL AREA DEL AGUJERO

Dt Dimetro exterior d la tubera.

Agujero = 0.7854 X ( D )

PASO No. 3
CONVERTIR LA DENSIDAD DE GR / CM3 A LB / GAL
1.54 GR / CC X 8.33 = 12.83 LB / GAL

(Q).- Gasto gal/min

A toberas = 0.7854 X (15 /32 ) 2 X 3

(l)
D 4.82

S-ar putea să vă placă și