Sunteți pe pagina 1din 53

ULTRASITE BTS SEMINAR

March 16, 2002


TZMCC Building

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

ULTRASITE EDGE BASE


STATION
Installation

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

ELECTRICAL REQUIREMENTS
TYPE OF POWER SUPPLY
Nominal Voltage
Permitted Voltage Range
AC Voltage frequency range
Configuration:

Input voltage

PWSB
DC
-48 / 60 V
-36 to-72V
N/A

Circuit Breaker /
Fuse Rate:
125A
100A
3 X 16A
3 X 25A

DC -48 V
DC -60 V
AC 230 V
AC 230 V

SSU + 12 TRX

AC 230 V

3 X 25A

SSU + 12 TRX + Heater

AC 230 V

3 X 35A

1 TRX
1 BTx
6 TRX
12 TRX
1BATA
NOKIA

PWSA
AC
208-230 V
166-276 V
50-60Hz

External DC supply
External DC supply
IBB + 6 TRX
IBB + 6 TRX + Heater

Configuration

BATA
AC
208-230 V
166-276 V
50-60Hz

TRX alone
Booster alone
With Cabinet
With Cabinet
Rectifier

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Typical Watts
190
310
2300
3900

Maximum watts Heat dissipation / W


295
391
2402
4803
1444

168
201

INSTALLATION
Property

Value

Connector Type

Antenna Connectors

6 + 6 optional

7/16 (DIN) female

Max. 48dBm / TRX


AC Supply

166-276 V

Screw latch 0.516mm

DC Supply

-36 to-72V

Screw latch 1650mm

Grounding

10.

Busbar, 5 and 8mm


screw

External Alarms And Controls

TTL

D-37 pin or optional


screw latch

Frame Number, Frame Clock,


Mains and SISU alarm input

RS-485

D-15 pin

Frame Number, Frame Clock,


Mains and SISU alarm output

RS-485

D-15 pin

Abis

2 Mbit/s (E1) or 1.5


Mbit/s (T1) PCM

TQ female for 120


ohm / BT43 female
for 75 ohm

DTRU FXC RRI

Radiolink i/o

TNC

Q1 Interface- SISU

RS-485

TQ

Q1 Interface

RS-485

TQ

MMI / ILMT

RS-232

BQ

13 MHz test clock

At BOI front panel

50 ohm SMB female

Test FCLK

At BOI front panel

50 ohm SMB female

Test / Monitor Interface

BOIA unit LVTTL

D-25 female

ESD Stud

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

ULTRASITE INDOOR CABINET

Roof

Core
Mechanics

Door

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

EMC Back

99614855

EXTERNAL INTERFACES

Cabinet
interface

External interface

Input/Output

X2
CABINET OUTPUT 1
X1
CABINET INPUT 1

Q1_, Q1_2, Q1_SSS

Q1_1

Q1_SSS

Qx connectors to be changed to D-9


Q1_2

External Alarms Inputs


Control Outputs

X8
EXTERNAL ALARMS INPUTS
X9
EXTERNAL ALARMS INPUTS/CONTROL OUTPUTS

00126254

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

EXTERNAL INTERFACES
Site Support
Interface

12 TX/RX Antennas
(also 6 on back)
as required

Cabinet
Interface
Abis Interface
access to
Transmission Unit

Customer
Interface
DC Power
Input - Right side
(AC Power
input - Left side, optional)
EMC Cover for
Transmission units
99591948

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

GROUNDING CONNECTIONS
Top view of cabinet

Side view of cabinet

Cabinet
ground cable

Ground nut
Cabinet
ground cable

Ground lug
Ground bolt

CRMA back

Antenna box
Cabinet
ground cable

M5
M8
Antenna box

Back cover
99591951

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

AC SINGLE PHASE POWER


CONNECTIONS

NOTE: Power input wiring must adhere to local codes.


L1, L2, L3 (Short Circuited)=Phase 1
N= Phase 2, PE= Ground

Shorting bar

L1
L2
L3
N

AC Power
input cable

PE

99613256

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

AC THREE PHASE POWER


CONNECTIONS
NOTE: Power input wiring must adhere to local codes.
L1= Phase 1, L2= Phase 2, L3= Phase 3
N= Neutral, PE= Ground

L1
L2
L3
N
AC Power
input cable

PE

99619126

10

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

DC INPUT POWER CABLING

(+)
V 48RTN
V 48N
(-)
DC Power
input cable

99613268

11

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

ANTENNA CABLING INSTALLATION


Antenna cable connector,
female, secured to inside
of panel (Note 2)

Antenna box, top removed


to show cable routing
Antenna cables routed beneath
power supply filters and into
antenna box
DC PSU filter
Cable clamp,
upper

AC PSU filter
(optional)

Antenna feeds
max. 12

DDU
or (RTC)

Antenna connector,
male

NOTES:
1. Cabinet details and plug-in units not shown
2. When using Bias-t or DU2A in OAKA, Bias-t/DU2A
mounts directly to inside of antenna box and antenna
cables connect to Bias-t/DU2A

12

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Cable clamp,
lower

00127238

Comparison of Plug in units


between Ultrasite & DE34
Ultrasite
VXxx (VXTA)
BOIx (BOIA)
WCxx (WCGA), DVxx (DVJA)
RTxx (RTJA)

DE34/DF34
TRUA
BCFA
AFEA
RTCC

M2xx (M2LA), M6xx (M6LA)

RMUJ

TSxx (TSGA)

PWSx (PWSB)

TRXA
CSUx , PSUx

13

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Structure of Nokia UltraSite GSM Base Station


Power Supply
DC (0-3)
AC (0-2)
TRX BB units (1-6)
TRX RF units
GSM (0-12)
EDGE GSM (0-12)
Receiver
Multicouplers
2-way (0-6)
6-way (0-2)

14

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Base Operations and


Interface Unit (1)
Transmission Units (1-4)
FC E1/T1
FXC E1
FXC E1/T1
FC RRI
FXC RRI
FXC STM-1
FXC E1B
Combiners & Duplex Filters
Dual Duplex Unit (0-6)
Wide Band Combiner (0-9)
Remote Tune Combiner (0-2)

COMBINING BY-PASS CONFIGURATION


CABLING
#993856X1
(2 places)

Antenna: TX/RX 2,
Diversity RX 1, #993744X3

Multipin Connection
to TRX Backplane
#993741X3

Antenna: TX/RX 1,
Diversity RX 2, #993744X3
RX 1

RX1

RX

DIV
RX

ANT 1
Warning! The weight of
this unit is over 10kg

TX
RX
IN

RX 1ext

TX 1

DRX1

DRX
IN

R (FLT)
Y (ALM)
G (OPR)
X1

RX 2
RX2

DRX2

RX 2ext

TX 2

RX

ANT 2

DIV
RX
TX

#993857X1
(6 places)

15

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

99616514

2-WAY WBC CONFIGURATION CABLING


#993856X1
(4 places)

Antenna: TX/RX 2,
Diversity RX 1, #993744X3

Multipin Connection
to TRX Backplane
#993741X3

RX1

Antenna: TX/RX 1,
Diversity RX 2, #993744X3

DRX1
RX

DIV
RX
TX

RX
IN

DRX
IN

RX2

DRX2

RX

TX1

TX OUT

TX2

TX1

TX OUT

TX2

DIV
RX

TX

RX 1
RX1

RX

DIV
RX

ANT 1
Warning! The weight of
this unit is over 10kg

TX
RX
IN

RX 1ext

TX 1

DRX1

DRX
IN

R (FLT)
Y (ALM)
G (OPR)
X1

RX 2
RX2

DRX2

RX 2ext

TX 2

RX

ANT 2

DIV
RX
TX

#993857X1
(8 places)

16

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

#993857X1 or #993747X3
depending on length,
(6 places)

99624799

4-WAY WBC CONFIGURATION CABLING


Antenna, Diversity RX
#993744X3

#993856X1
(4 places)

Antenna: TX/RX
#993744X3

#993857X1
(8 places)

RX1

DRX1
RX

RX
IN

DRX
IN

RX2

DRX2
RX

RX1

DIV
RX
TX

TX1

TX OUT

TX2

TX

TX1

TX OUT

TX2

TX

TX1

TX OUT

TX2

DIV
RX

DRX1
RX

RX
IN

DRX
IN

RX2

DRX2

DIV
RX

RX 1

RX 1ext

TX 1
RX

DIV
RX

ANT 1
Wa rning ! The weight of
this unit is over 10kg

TX

R (FLT)
Y (ALM)
G (OPR)
X1

Multipin Connection
to TRX Backplane
#993741X3

#993857X1 or #993747X3
depending on length,
(7 places)

RX 2

RX 2ext

TX 2
ANT 2

99624806

17

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

WCGA PICTURES

18

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Nokia UltraSite GSM Base Station


Mechanics

19

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Common core
mechanics in
Nokia UltraSite
GSM BTS
Outdoor and
Nokia UltraSite
GSM BTS Indoor

Common plugin units

REMOTE TUNE COMBINER


CONFIGURATION CABLING
NOTE: Unlabeled cables are #993857X1
(18 places)
#993856X1

Antenna: TX/RX
#993744X3

Multipin Connection
to TRX Backplane
#993741X3
RX1

Antenna: Diversity RX
#993744X3

DRX1

RX

DIV
RX

DRX
TX 1
TX

RX2

DRX2

RX

DIV
RX
TX 2
TX

RX3

DAnt

DRX3

RX

DIV
RX

TX 3
WARNING! The weig ht of
this un it is over 10kg

TX
RX
IN

DRX
IN

RX4

DRX4

P
W
R
I
N

RX

DIV
RX

TX 4
TX

R( FLT)
Y(ALM)
G(OPR)

Ant

RESET
RX5

DRX5

RX

DIV
RX

TX 5

TX

RX6

DRX6

RX

DIV
RX

TX 6
TX

RX

RXExt

99624818

20

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

ULTRASITE EDGE BASE


STATION
Commissioning

21

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

COMMISSIONING PROCEDURE
Start BTS Manager
Start Ultrasite HW configurator

Create the HW configuration file


Send HW configuration file to BTS

Download Software to BTS

Upgrade or Download the Software


Transmission unit configuration
Start Ultrasite BTS Hub manager

Define LIF settings


Define synchronization settings
Create cross-connections ( Traffic Manager )
22

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

COMMISSIONING PROCEDURE

Manual commissioning
Start Commissioning Wizard

Open BTS commissioning Wizard


Check the Manual commissioning
option

Start manual commissioning


Get commissioning report
Adjust 13Mhz clock

23

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

HW Configurator

24

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Create HW Configuration
Send to BTS

HW Configurator

25

NOKIA

Open BTS Manager, Wait until it detect all plug in units. Click Tools then click HW Configurator

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

HW Configurator

26

Wait until the connection establish, click Configuration, then click Configuration Wizard.
In case you have ready made HWDB from your computer, open it

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Actual HW Configurator

27

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

HW Cofigurator

28

NOKIA

After creating necessary HW configuration, click BTS from the menu, then click Send to BTS
Sending to BTS was successful when Identical with HW Configurator Information displayed.
Then click Close, then exit HW Configurator

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

SW Upgrade & Downloading

29

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

SW Upgrading

SW Upgrade / Download

30

NOKIA

Click BTS SW, then click SW Upgrade

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

31

NOKIA

SW Upgrade / Download

Click Open Master File

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

SW Upgrade / Download

32

NOKIA

Select the master file ( BTS_S303.080 ), then click Open

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

33

NOKIA

SW Upgrade / Download

Click Load, then wait until the all the files were downloaded.

The BTS will reset automatically after the downloading was finished.

To verify if SW was downloaded, click BTS SW, then click SW Version. The SW must be the same as below

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Hub Manager

LIF Setting

Cross Connection

Table )

34

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Synchronyzation
Traffic Manager ( Branching

Hub Manager

35

NOKIA

Click Tools, then click Hub Manager

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Hub Manager

36

NOKIA

Wait until the computer connects to the equipment, then click E1

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Actual Hub Manager

37

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

38

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

TRX Loop Test


Abis Loop Test
EAC Setting
Commissioning Report

Commissioning Wizard

39

NOKIA

Click Commissioning in the menu, then click Commissioning Wizard

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

40

NOKIA

Select Manual Commissioning then click Next

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

41

NOKIA

Provide the proper information then click Next

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

42

NOKIA

Click Start Commissioning button

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

Note: When the BTS BSC connection is ok (PCM connection is thru) , the BTS will start to configure

& start TRX loop test, Abis loop test automatically.


When BTS BSC connection in not ok, display will appear asking to use the current SW, click yes . The
Site will configure but will not make test automatically.

43

NOKIA

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

44

NOKIA

Test made when Abis connection is ok

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

45

NOKIA

Wait until all the test was finished, then click Next
If the test was not done automatically because abis is not ok, click Manual button for manual test

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

46

NOKIA

For Manual test, input the TRX number & timeslot then click Start

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

47

NOKIA

After make the test on all TRX, click Close

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

48

NOKIA

Then click Next

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

49

NOKIA

Check EAC input then click Next . Check every EAC input if it changes from open to close by looping at the
DDF. In case no changes, check the alarm cable from ddf to bts

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

50

NOKIA

Click Next if input 13 to 24 are not in use, otherwise do the same as in input 1 to 12

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

51

NOKIA

Click Next if alarm outputs are not in use

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Commissioning Wizard

52

NOKIA

Save the commissioning report for site folder then click Finish

Ultrasite Seminar.PPT/ 15.03.02 / F. Maybituin

Nokia UltraSite GSM Base Station


Indoor
Mechanical Characteristics
1700 x 600 x 570 mm (H x W x D)
- Identical footprint to IntraTalk BTS

Weight
- Max weight (12 TRX) 266 kg
- Heaviest single part 58 kg (core
mechanics)
- Heaviest plug-in unit 17 kg (RTC)

Acoustic noise (max): 60 dB (A)


Climatic conditions: -5C ... +50 C
Ingress Protection Class:

IP 20

BTS core and cabinet door provides


EMC shielding
53