THE IMPORTANCE OF GEOTECHNICAL LABORATORY TESTING


Soil can exist as a naturally occurring material in its undisturbed state, or as a
compacted material. Geotechnical engineering involves the understanding and
prediction of the behavior of soil. Like other construction materials, soil
possesses mechanical properties related to strength, compressibility, and
permeability. It is important to quantify these properties to predict how soil will
behave under field loading for the safe design of soil structures (e.g.
embankments, dams, waste containment liners, highway base courses, etc.), as
well as other structures that will overly the soil. Quantification of the mechanical
properties of soil is performed in the laboratory using standardized laboratory
tests.

CIVIL ENGINEERING DEPARTMENT


BALOCHISTAN UNIVERSITY OF INFORMATION TECHNOLOGY
ENGINEERING & MANAGEMENT SCIENCES, QUETTA

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

ii

Geotechnical and Foundation engineering Lab Manual

CONTENTS
1

IN PLACE SOIL DENSITY USING SAND CONE METHOD

COEFFICIENT OF PERMEABILITY (CONSTANT HEAD METHOD)

11

COEFFICIENT OF PERMEABILITY (FALLING HEAD METHOD)

21

DIRECT SHEAR TEST

30

ONE DIMENSIONAL CONSOLIDATION

STANDARD PENETRATION TEST

63

UNCONFINED COMPRESSION TEST

73

TRIAXIAL TEST

82

PLATE LOAD TEST

96

10

TEST

CALIFORNIA BEARING RATIO TEST

BIBLIOGRAPHY

42

106
118

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

iii

In situ Density By sand Cone Method

1
IN PLACE SOIL
DENSITY USING
SAND CONE
METHOD

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

1.1

INTRODUCTION

Basically, both the sand-cone and balloon-density methods use the same principle. That
is, one obtained a known weight of damp (or wet) soil from a small excavation of
somewhat irregular shape (a hole) in the ground. If one knows the volume of the hole, the
wet density is simply computed as

wet

weight of damp soil


volume of hole

and if one obtained the water content w of the excavated material, the dry unit weight of
the material is

dry wet
1 w
The sand cone method is an indirect means of obtaining the volume of the hole. The sand
used (often Ottawa sand) is generally material passing the No. 20 sieve but retained on
the No. 30 sieve. If one has a constant-density material of, say, 1.60 g/cm and pouring
4800 g of this material into an irregular-shaped hole, the volume of the hole can be found
by proportion as:

V
1cm 3

4800 1.60 g / cm 3
Vhole

1.1.1

wt. of material used to fill hole


unit wt.of material

DEFINITIONS

BULK DENSITY
Bulk density refers to the weight (mass) of soil per unit volume and the soils bulk density
is normally expressed in g cm-3 (weight divided by volume).

UNIT WEIGHT
Unit weight is defined as weight per unit volume.

1.2

OBJECTIVES OF TEST

The object of this test is to determine the dry density of natural or compacted soil, inplace and its degree of compaction.

1.3

SCOPE OF TEST

Once compaction criteria are established for the soil to be used at a particular site,
generally with both moisture and density limitations, some means of verification of the
results must be used. On all small projects and nearly all-large projects, this verification is

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

achieved by either the sand-cone method or the balloon density method. On a few large,
nuclear devices have been and are considered further.

1.4

STANDARD REFERENCES

ASTM: D 1556-64
AASHTO: T 191-61

1.5

MATERIALS & EQUIPMENT

The test equipment consists of:


1. Sand cone apparatus
2. Shovels (Digging tools)
3. Metal tray with a central circular hole of diameter equal to the diameter of the
pouring cone
4. Balance accurate to 1g
5. clean, uniformly graded sand ranging from #20 to #30 sieve such as Ottawa Sand
6. Paint brush to collect soil from template
7. Hammer and three nails to fix the metal tray on the spot
8. Spoon
9. plastic air tight bag for carrying wet excavated soil from field to laboratory
10. Oven with temperature kept at about 105-110oC

Figure 1.1 Sand-Cone Apparatus

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

Figure 1.2 Ottawa sand

1.6

PREPARATION OF SAMPLE AND TEST


SPECIMEN

Carefully collect a sample from undisturbed core of soil adjacent to the points of soil
moisture determination using the tins provided. Trim off excess soil and wrap core in
labeled polythene bag for transport to laboratory.

1.7

ADJUSTMENT AND CALIBRATION OF


INSTRUMENT

Prior to determining the bulk density of the sand and prior to conducting density tests, the
technician is required to determine the weight of sand needed to fill the large cone of the
density apparatus and the accompanying base plate. This weight is determined to the
nearest 0.01 kilogram and is referred to as the Cone Correction. The density apparatus
and the base plate are required to remain together and not be interchanged with other
devices without recalculating the Cone Correction.
The procedure for determination of the Cone Correction is detailed in AASHTO T 191
and is summarized as follows:
1. Fill the apparatus with the calibration sand and record the weight to the nearest
0.01 lb
2. Place the base plate on a clean, level surface
3. Invert the apparatus onto the base plate and open the valve to allow the cone and
the base plate to fill with sand
4. When the sand stops flowing into the cone, shut the valve and weigh the apparatus
to the nearest 0.01 lb
5. The difference between the full weight of the apparatus and the final weight after
filling the cone is referred to as the Cone Correction.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

1.8
1.8.1

TEST PROCEDURE
DETERMINATION OF MASS OF SAND FILLING THE CONE

1. Fill the clean closely graded sand in the sand-pouring cylinder up to a height of
1cm below the top. Determine the total mass/weight of Bottle + Cone +Sand (M1).
2. Open the valve and allow the sand to flow out. Close the valve when no further
movement of sand is observed. Lift the jar carefully. Weigh the sand collected on
the glass surface. Its mass (Mc) is the mass of sand filling the pouring cone. Or
remove the bottle and cone combination from the base plate, and determine its
mass (M2), thus the mass of sand to fill the cone can be determined as:
Mc = M1 M2
Pour the sand back into the cylinder, to have the same constant mass.

1.8.2

DETERMINATION OF BULK DENSITY OF SAND

1. Determine the volume of the calibrating container. It would be either mentioned


or can be by measuring the diameter or by filling it with water full to the top and
finding the mass of water, it is therefore
V

For pure water normally the mass density can be taken as = 1g/cm3
2. Place the sand-pouring cylinder concentrically on the top of the calibrating
container. Open the shutter and permit the sand to run into the container. When
there is no further movement of sand, close the shutter. Remove the cylinder and
find its mass. Thus mass per unit volume will give the bulk density of the sand.
On other hand this can also be done by taking a proctor compaction mold and,
using a spoon, filling it with Ottawa sand. Avoid any vibration of other means of
compaction of the sand poured into the mould. When the mold is full, strike off
the top of the mould with the steel straight edge, determine the mass of the sand in
the mold. The bulk density of the Ottawa sand can be then be given as:

M
V

Where
M = Mass of the sand filling the mould.
V = Volume of the mould (1/30 ft3)
d = Bulk density of the sand.

1.8.3

DETERMINATION OF DRY DENSITY OF SOIL IN-PLACE

1. Expose about 45cm2 area of the soil to be tested and trim it down to level surface.
Keep the tray on the level surface and fix it by the help of nails in its position and
excavate a circular hole of approximately 10cm in diameter and 15 cm deep and
collect all the excavated soil in the tray. Find the mass of the excavated soil.
2. Remove the tray, and place the sand-pouring cylinder concentrically on the hole.
Open the shutter and permit the sand to run into the hole. Close the shutter when

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

no further movement of the sand is seen. Remove the cylinder and determine its
mass.
3. Keep a representative sample of the excavated soil for water content
determination.

1.9

CALCULATIONS

Unit weight of soil

Dry density

1.10

RESULTS

The dry unit weight of the soil = _________g/cm3


Dry unit weight/ specific weight

1.11

ENGINEERING USES OF TEST RESULTS

This test is applied in the cases like embankment and pavement construction; and is
basically a quality control test where certain degree of compaction is required. This test
is also used in stability analysis of embankments and slopes, for the calculation of
pressure in underlying strata for settlement problems and also designs of underground
structures.

1.12

PRECAUTIONS

1. The excavation during sand cone method should be as rapid as possible to


maintain the representative moisture content.
2. The field test holes may be quite small, thus the error multiple is largest is
absolutely essential that no soil be lost during excavation
3. The largest possible water content sample should be used to improve test
reliability.
4. When using the sand cone method avoid vibrating either the ground in the area or
the sand jug as this will introduce too much sand into the hole thus causing an
apparent increase in the holes volume.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

1.13

SAMPLE PROBLEM
SOIL TESTING LABORATORY
FIELD UNIT WEIGHT-SAND CONE METHOD

Sample No.
15
Boring No.
B-21
Depth of sample
3 ft
Description of Sample
Reddish brown silty clay
Tested by
John Doe
(A)

Project No.
Location

SR 2828
Newell, N.C

Date

1/26/89

Determination of mass of sand filling the cone

The total mass of Bottle + Cone +Sand before filling the cone (M1)

9098gm

The total mass of Bottle + Cone +Sand after filling the cone (M2)

7268gm

Mass of the sand filling the cone (Mc) = M1- M2

1830gm

(B)

Determination of bulk density of sand

The volume of the calibrating container (V)

2305cm3

The mass of the sand in the mold/calibrating container (M3)

3400gm

The bulk density of the Ottawa sand s M 3


V
(C)
Determination of dry density of soil in- place

1.47 gm/cm3

The mass of the excavated wet soil M4

2658gm

The total mass of Bottle + Cone +Sand before filling the hole (M5)

9066gm

The total mass of Bottle + Cone +Sand after filling the hole (M6)

4980gm

Mass of the sand filling the hole (Mh) = M5- M6 Mc

2256gm

Volume of hole Vh

Mh

1535cm3

M4
M
or 4 s
Vh
Mh
Unit weight of soil g
Bulk density of soil

1.73 gm/cm3
16097 kg/cm3

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

(D)

Water content determination

Mass of can + wet soil M7

106.41 gm

Mass of can + dry soil M8

103.38 gm

Mass water Mw = M7 M8

3.03 gm

Mass of can M9

15.35 gm

Mass of dry soil Md = M8 M9


Water content
Dry density

88.03 gm

Mw
Md

3044%

Dry unit weight/ specific weight

1.672 gm/cm3

Result
The dry unit weight of the soil = ______1.672___ gm/cm3

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

SOIL TESTING LABORATORY


FIELD UNIT WEIGHT-SAND CONE METHOD
Sample No.
Boring No.
Depth of sample
Description of Sample
Tested by

(A)

Project No.
Location

Date

Determination of mass of sand filling the cone

The total mass of Bottle + Cone +Sand before filling the cone (M1)
The total mass of Bottle + Cone +Sand after filling the cone (M2)
Mass of the sand filling the cone (Mc) = M1- M2
(B)

Determination of bulk density of sand

The volume of the calibrating container (V)


The mass of the sand in the mold/calibrating container (M3)
The bulk density of the Ottawa sand s M 3
V
(C)
Determination of dry density of soil in- place
The mass of the excavated wet soil M4
The total mass of Bottle + Cone +Sand before filling the hole (M5)
The total mass of Bottle + Cone +Sand after filling the hole (M6)
Mass of the sand filling the hole (Mh) = M5- M6 Mc
Volume of hole Vh

Mh

M4
M
or 4 s
Vh
Mh
Unit weight of soil g
Bulk density of soil

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

In situ Density By sand Cone Method

(D)

Water content determination

Mass of can + wet soil M7


Mass of can + dry soil M8
Mass water Mw = M7 M8
Mass of can M9
Mass of dry soil Md = M8 M9
Water content
Dry density

Mw
Md

Dry unit weight/ specific weight

Result
The dry unit weight of the soil =

gm/cm3

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

10

Coefficient Of Permeability by Constant Head Method

COEFFICIENT
OF
PERMEABILITY
(Constant Head Method)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

11

Coefficient Of Permeability by Constant Head Method

2.1

INTRODUCTION

In geotechnical engineering problems measuring the flow of water through the soil is a
very important consideration. Soil has pores due to inter-particle spaces (voids). The
interconnectivity of voids determines the permeability characteristics of soil. Thus, rock,
concrete, and other porous material may also be permeable (pervious). Materials such as
clays and silts in natural deposits have considerable porosity but are practically
impervious or have permeability significantly low (in comparison to sand or gravel).
The coefficient of permeability of soil is important in various aspects such as:
Determining the seepage through or beneath dams and levees and into water wells; in
stability analyses of hydraulic structures through evaluation of uplift or seepage forces;
and in regulating seepage control and design of seepage velocities to check erosion in
earthen structures
The other important applications are in estimation of ground water flow, percolation,
surface recharge and yield from wells.

2.1.1

DEFINITIONS

PERMEABILITY
Permeability is the ease with which the water flows through a soil medium.

COEFFICIENT OF PERMEABILITY
The rate of flow under laminar flow conditions through a unit cross sectional are of
porous medium under unit hydraulic gradient is defined as coefficient of permeability.

2.2

OBJECTIVES

To introduce a method of determining coefficient of permeability of a coarse-grained soil


by constant head method.

2.3

SCOPE

The test method measures the flow rate of water through a soil specimen of a known
gross cross-sectional area, applying constant head and using Darcys expression for
determining its permeability constant.

2.4

STANDARD REFERENCE

ASTM D234-68
AASHTO T215-66

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

12

Coefficient Of Permeability by Constant Head Method

2.5
1.
2.
3.
4.
5.
6.
7.

APPARATUS
Permeability device (Permeameter)
Constant head tank
Thermometer, range 0 to 50oC, accurate to 0.1oC
Stop watch.
Graduated cylinder.
De-aired distilled water
Coarse-grained soils

Figure 2.1 constant head assembly

2.6

TEST PROCEDURE

1. Measure the initial mass of the pan along with the dry soil (M1).
2. Remove the cap and upper chamber of the Permeameter by unscrewing the
knurled cap nuts and lifting them off the tie rods.
3. Measure the inside diameter of upper and lower chambers. Calculate the average
inside diameter of the Permeameter (D).
4. Place one porous stone on the inner support ring in the base of the chamber then
place a filter paper on top of the porous stone.
5. Mix the soil with a sufficient quantity of distilled water to prevent the segregation
of particle sizes during placement into the Permeameter.
6. Enough water should be added so that the mixture may flow freely.
7. Using a scoop, pour the prepared soil into the lower chamber using a circular
motion to fill it to a depth of 1.5 cm. A uniform layer should be formed.
8. Use the tamping device to compact the layer of soil. Use approximately ten rams
of the tamper per layer and provide uniform coverage of the soil surface. Repeat
the compaction procedure until the soil is within 2 cm. of the top of the lower
chamber section.
9. Replace the upper chamber section, and dont forget the rubber

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

13

Coefficient Of Permeability by Constant Head Method

10. Gasket that goes between the chamber sections. Be careful not to disturb the soil
that has already been compacted. Continue the placement operation until the level
of the soil is about 2 cm. below the rim of the upper chamber.
11. Level the top surface of the soil and place a filter paper and then the porous stone
on it.

Figure 2.2 Half assembled permeameter.


12. Place the compression spring on the porous stone and replace the chamber cap and
its sealing gasket. Secure the cap firmly with the cap nuts.
13. Measure the sample length at four locations around the circumference of the
Permeameter and compute the average length. Record it as the sample length.
14. Keep the pan with remaining soil in the drying oven.
15. Adjust the level of the funnel to allow the constant water level in it to remain a
few inches above the top of the soil.
16. Connect the flexible tube from the tail of the funnel to the bottom outlet of the
Permeameter and keep the valves on the top of the Permeameter open.
17. Place tubing from the top outlet to the sink to collect any water that may come
out. Open the bottom valve and allow the water to flow into the Permeameter.
18. As soon as the water begins to flow out of the top control (de-airing) valve, close
the control valve, letting water flow out of the outlet for some time.
19. Close the bottom outlet valve and disconnect the tubing at the bottom.
20. Connect the funnel tubing to the top side port. Open the bottom outlet valve and
raise the funnel to a convenient height to get a reasonable steady flow of water.
21. Allow adequate time for the flow pattern to stabilize.
22. Measure the time it takes to fill a volume of 750 - 1000 ml using the graduated
cylinder, and then measure the temperature of the water.
23. Repeat this process three times and compute the average time, average volume,
and average temperature. Record the values as t, Q, and T, respectively.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

14

Coefficient Of Permeability by Constant Head Method

24. Measure the vertical distance between the funnel head level and the chamber
outflow level, and record the distance as h.
25. Repeat step 17 and 18 with different vertical distances.
26. Remove the pan from the drying oven and measure the final mass of the pan along
with the dry soil (M2).

2.7

CALCULATIONS

Using Bowles apparatus for determination permeability coefficient by measuring flow


through soil under a constant head is calculated from the following equation
QL
k
C
htA
Where;
Q = quantity of flow,
cm3 or ml
L = length of the sample,
cm
h = applied head (constant)
cm
t = time interval
seconds
A = cross-sectional area of the sample
cm2
C = Temperature correction for viscosity of water at 20C
Result
The coefficient of permeability of the given coarse-grained soil by Constant Head
Permeability test is found to be, k =___________________cm/s.
Soil

Coefficient. of Perm., k,
cm/sec
>10-1
10-1 > k > 10-3

Degree of Permeability

Gravel
Very high
Sandy gravel, clean sand, fine
High to Medium
sand
Sand, dirty sand, silty sand
10-3 > k > 10-5
Low
Silt, silty clay
10-5 > k > 10-7
Very low
Clay
<10-7
Virtually impermeable
Table 2.1 soil permeability properties

2.8

ENGINEERING USES OF TEST RESULTS

The important applications of permeability are in estimation of ground water flow,


percolation, surface recharge and yield from wells
In the design of geotechnical engineering projects, one of the most important soil
properties of interest to the soils engineer is permeability. To some degree, permeability
will play a role in the design of almost any structure. For example, the durability of
concrete is related to its permeability. In designs that make use of earthen materials (soils
and rock, etc.)The permeability of these materials will usually be of great importance.
To illustrate the importance of permeability in geotechnical design, consider the
following applications where knowledge of permeability is required.
Permeability influences the rate of settlement of a saturated soil under load.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

15

Coefficient Of Permeability by Constant Head Method

The rate of flow to wells from an aquifer is dependent on permeability.


The design of earth dams is very much based upon the permeability of the soils used.
The performance of landfill liners is based upon their permeability.
The stability of slopes and retaining structures can be greatly affected by the permeability
of the soils involved.
Filters to prevent piping and erosion are designed based upon their permeability.
Soils are permeable (water may flow through them) because they consist not only of
solid, but a network of interconnected pores. The degree to which soils are permeable
depends upon a number of factors, such as soil type, grain size distribution and soil
history. This degree of permeability is characterized by the coefficient of permeability.

2.9

PRECAUTIONS

1. The head may be varying.


2. The temperature should be constant
3. Be careful not to jar or bump the apparatus at all.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

16

Coefficient Of Permeability by Constant Head Method

2.10 SAMPLE PROBLEM


SOIL TESTING LABORATORY
CONSTANT HEAD PERMEABILITY TEST
Description of soil Brown, medium coarse sand
Sample No.
2
Location

soil laboratory

Unit Weight Determination


length between manometer outlets, L (cm)

11.43

Diameter of soil specimen, D (cm)

10.16

Cross sectional area of soil specimen A (cm2) (i.e. D2/4)

81.0837088

Height H1 ,(cm)

20

Height H2 ,(cm)

4.5

Height of specimen (cm) (H1-H2)

15.5

Volume of specimen (cm3)

1256.797486

weight of air dried soil before compaction, W1 (g)

3200

Weight of unused remaining portion of soil after compaction, W2 (g)

1102.5

Weight of soil specimen (air dried) (g)

2097.5

Unit weight of soil specimen (air dried ) (lb/ft3)

104.140883

Water Content of Soil Specimen (air dried) (%)

1.100079428

can no.

2-A

weight of air dried soil + can

308.17

weight of oven dried soil + can

305.4

weight of can

53.6

water content of air dried soil (%)

1.100079428
3

Dry unit weight of soil specimen (lb/ft )


specific gravity of soil

103.0077163
2.71

Volume of solids (ft )

0.60913826

Volume of voids (ft3)

0.39086174

Void ratio e, of soil specimen

0.641663421

Permeability Test
length between manometer outlets, L (cm)
Cross sectional area of soil specimen A (cm2)

11.43
81.0837088

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

17

Coefficient Of Permeability by Constant Head Method

Test
No.

Average
flow,

Time of
collection

Temperatu
re of water,
T

Manometer Readings

(oC)

Head
difference,

QL
C
htA

h1

h2

(cm)

(cm)

(cm)

(cm/sec)

Ratio of viscosity at
ToC/Viscosity at
20oC

Permeability at
20oC,
k20

(cm3)

(sec)

250

65

23

10.9

5.4

5.5

0.0986

0.9311

0.091785

250

63

24

10.9

5.4

5.5

0.1017

0.9097

0.092523

250

64

24

10.9

5.4

5.5

0.1001

0.9097

0.091077

(cm/s)

Result
The coefficient of permeability of the given coarse-grained soil by Constant Head Permeability test is found to be,
k =_0.0918__cm/s.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

18

Coefficient Of Permeability by Constant Head Method

SOIL TESTING LABORATORY


CONSTANT HEAD PERMEABILITY TEST
Description of soil
Sample No.

Location

Unit Weight Determination


length between manometer outlets, L (cm)
Diameter of soil specimen, D (cm)
Cross sectional area of soil specimen A (cm2) (i.e. D2/4)
Height H1 ,(cm)
Height H2 ,(cm)
Height of specimen (cm) (H1-H2)
Volume of specimen (cm3)
weight of air dried soil before compaction, W1 (g)
Weight of unused remaining portion of soil after compaction, W2 (g)
Weight of soil specimen (air dried) (g)
Unit weight of soil specimen (air dried ) (lb/ft3)
Water Content of Soil Specimen (air dried) (%)
can no.
weight of air dried soil + can
weight of oven dried soil + can
weight of can
Water content of air dried soil (%)
Dry unit weight of soil specimen (lb/ft3)
specific gravity of soil
Volume of solids (ft3)
Volume of voids (ft3)
Void ratio e, of soil specimen
Permeability Test
length between manometer outlets, L (cm)
Cross sectional area of soil specimen A (cm2)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

19

Coefficient Of Permeability by Constant Head Method

Test
No.

Average
flow,

Time of
collection

Temperatur
e of water,

Q
(cm3)

t
(sec)

T
(oC)

Manometer Readings
h1
(cm)

h2
(cm)

Head
difference,
h
(cm)

QL
C
htA

Ratio of viscosity at
ToC/Viscosity at 20oC

Permeabili
ty at 20oC,
k20
(cm/s)

(cm/sec)

Result
The coefficient of permeability of the given coarse-grained soil by Constant Head Permeability test is found to be, k
=___________________cm/s.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

20

Coefficient Of Permeability by Falling Head Method

COEFFICIENT
OF
PERMEABILITY
(Falling Head Method)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

21

Coefficient Of Permeability by Falling Head Method

3.1

INTRODUCTION

Fine soils such as silt and clay have considerable low permeability, which makes
determination of their permeability constant practically impossible when using constant
head test. Hence alternate method is suggested which measures the flow of water through
soil sample by applying variable head that decreases with time as the level of water above
the soil samples decreases (falling head). The drop in the level is of water in a known
time is measured for calculating the coefficient of permeability.

3.1.1

DEFINITIONS

PERMEABILITY
Permeability is the ease with which the water flows through a soil medium.

3.2

OBJECTIVES

To determine the coefficient of permeability of a fine grained soil by falling head method
such as fine sand, silt, or clay. This test may also be used for coarse grained soils.

3.3

SCOPE

The test method is applicable to fine-grained soils through which rate of flow of water is
measured keeping known gross cross-sectional area constant while the applied head
(hydraulic potential) decreases gradually with time. This test determines the permeability
of sample that has permeability less than about 10-3cm/s (less permeable soil).

3.4

STANDARD REFERENCE

ASTM D234-68
AASHTO T215-66

3.5

APPARATUS

1.
2.
3.
4.
5.
6.

Falling Head Permeability device (Permeameter).


Thermometer.
Stop watch.
Graduated cylinder.
Fine grained material
Ring stand with test-tube clamp or other means to develop a differential head
across soil sample.
7. Burette with stand.
8. Electronic balance (LC = 0.1g)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

22

Coefficient Of Permeability by Falling Head Method

Figure 3.1 Assembled falling head apparatus

3.6

PROCEDURE

1. Weigh the Permeameter mold with the base plate and porous stone attached. Also
measure the inside mold diameter and height in order to calculate the crosssectional area and sample length, as well as the cross-sectional area of the burette,
which can be determined from the distance between graduations.
2. Fill the mold with the soil sample by a method appropriate to the material and
purpose of testing.
3. For tests on loose cohesion less soils: Assemble the Permeameter base and mold,
then using a large funnel let the dry cohesion less soil rain into the mold at a
constant rate. The funnel should be kept about one inch above the soil surface and
continuously moved in a spiral motion allowing the sand to accumulate uniformly.
An oven-dry moisture determination (AASHTO T 265) shall be made in order to
compute the dry density of the soil.
4. For tests on compacted soils: Using the Permeameter molds, embankment type
materials are compacted in accordance with AASHTO T-99, Method C, while
base and stabilized sub grade type materials are compacted in accordance with
AASHTO T 180. After compaction, the mold is removed from the compaction
base and assembled in the Permeameter base.
5. Weigh the assembled mold and base plate with soil and determine the density of
dry soil. Measure the length of the soil sample L. If material is loose, the length of
the soil sample should be measured before and after the permeability tests to
determine any change in length due to consolidation of soil. The final value of L is
used for computations of K.
6. Place a piece of filter paper on top and bottom of the sample, then place the
perforated disc. Making sure the rim is clean, place the gasket and seat the cover.
7. Using a vacuum pump or suitable aspirator, (Fig. 1) evacuate the specimen a
minimum of 15 minutes to remove air adhering to soil particles and from the voids
(Note 1). Follow the evacuation by a slow saturation of the specimen from the

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

23

Coefficient Of Permeability by Falling Head Method

bottom upward, under vacuum, in order to free any remaining air in the specimen.
De-aired water is recommended for the saturation of the specimen. The water
supply should be slightly elevated in order to produce a small hydraulic head
during saturation.
8. Note 1: A maximum vacuum of 250 mm (10 in.) mercury is recommended. Some
sandy soils with permeability greater than 10- should not be subjected to a
vacuum greater than 125 mm (5 in.) mercury. In no case shall a combination of
vacuum and hydraulic head be great enough to produce turbulent flow in the
specimen during saturation.
9. After the specimen has been saturated and the Permeameter is full of water,
partially close the valve on the outlet tube to produce a minimum steady state flow
at the inlet, and then disconnect the vacuum.
10. Immediately attach the Permeameter to the rubber tube at the base of the burette.
The burette and the rubber tube should already be filled and flowing with water
from a supply, which has been temperature stabilized and de aired. The
Permeameter should now be free of air bubbles.
11. Close the outlet valve and fill the burette to a convenient height.
12. Remember that the inlet valve is partially open and should be completely opened
at this point. Measure the hydraulic head across the sample to obtain ho.
13. Disconnect the outlet tube from the saturation reservoir and place it in a filled
container.
14. Open the outlet valve and simultaneously start timing the test. Allow water to flow
through the sample until the burette is almost empty.
15. Simultaneously record the elapsed time and clamp only the outlet tube. Measure
the hydraulic head across the sample at this time to obtain h1. Take the
temperature of the test.
16. Refill the burette and repeat step Section 4.9 two additional times.
17. Take the temperature each time.
18. Compute the coefficients of permeability at the test temperature, kt, for each trial,
and k at 20C using the correction values from table 1.
19. Average all three or the two closest values for k = 20.

3.7

CALCULATIONS

The coefficient of permeability is calculated from the following equation,


k

aL h1
ln C
At h2

Where,
a = cross-sectional area of burette
cm2
L = length of the sample
cm
h1 = Initial hydraulic head
cm
h2 = Final hydraulic head
cm
t = time interval
seconds
A = cross-sectional area of the soil sample
cm2
C = Temperature correction for viscosity of water at 20C.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

24

Coefficient Of Permeability by Falling Head Method

3.8

RESULTS

The coefficient of permeability of the given fine-grained soil by Falling Head


Permeability test is found to be, k =___________________cm/s.

3.9

ENGINEERING USES OF TEST RESULTS

Practical uses of falling head permeability test are


1.
2.
3.
4.

Settlements in structures
Methods for lowering the ground water table during construction
Design grouting pressures and quantities for soil stabilization
Freeze Thaw movements in soils (Note that coefficient of permeability ( k) varies
with temperature
5. as the viscosity of the fluids changes with temperature)
6. Design of recharge pits

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

25

Coefficient Of Permeability by Falling Head Method

3.10

SAMPLE PROBLEM
SOIL TESTING LABORATORY
FALLING HEAD PERMEABILITY TEST

Description of soil Brown, medium coarse sand


Sample No.
2
Location

Soil laboratory

Unit Weight Determination


Weight of Permeameter (mold) with the base plate and
gasket attached + soil (g)
Weight of empty Permeameter (mold) with the base plate
and gasket attached (g)

3401.1
1098.5

Weight of soil specimen (g)

2302.6

Diameter of soil specimen, D (i.e., inside dia of mold)(cm)

10.16

Cross sectional area of soil specimen(ie 3.142*D2/4)


Length of soil specimen in Permeameter, L (cm)

81.0837088
15.8

volume of soil specimen

1281.122599

Unit weight of soil specimen (air dried)

112.1533881

Water content of soil specimen (air dried) (%)

1.100079428

can no.

2-A

weight of air dried soil + can

308.17

weight of oven dried soil + can

305.4

weight of can

53.6

Water content of soil specimen (air dried) (%)

1.100079428

Dry unit weight of soil specimen (lb/ft3)

110.9330365

Specific gravity of soil

2.71

Volume of solids

0.656004805

Volume of voids

0.343995195

Void ratio, e, of soil specimen

0.524379078

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

26

Coefficient Of Permeability by Falling Head Method

Ratio of
viscosity at
ToC/Viscosity
at 20oC

Permeability at
20oC,
k20
(cm/s)

22

0.022223465

0.9531

0.02118

32.6

22

0.022018955

0.9531

0.02099

31.7

22

0.022644099

0.9531

0.02158

Temperature
of water,
T
(oC)

20

32.3

150

20

150

20

h2

(cm)

(cm)

150

2
3

Test
No.

permeability
at T (oC),
KT
(cm/s)

Test
duration,
t
(sec)

h1

Calculation
The coefficient of permeability is calculated from the following equation,
aL h1
k
ln C
At h2
Result
The coefficient of permeability of the given fine-grained soil by Falling Head
Permeability test is found to be, k20 oC =________0.06375___________cm/s.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

27

Coefficient Of Permeability by Falling Head Method

SOIL TESTING LABORATORY


FALLING HEAD PERMEABILITY TEST
Description of soil
Sample No.

Location

Unit Weight Determination


Weight of permeameter (mold) with the base plate and gasket attached + soil (g)
Weight of empty permeameter (mold) with the base plate and gasket attached (g)
Weight of soil specimen (g)
Diameter of soil specimen, D (ie inside dia. of mold)(cm)
Cross sectional area of soil specimen(ie 3.142*D2/4)
Length of soil specimen in permeameter, L (cm)
volume of soil specimen
Unit weight of soil specimen (air dried)
water content of soil specimen(air dried) (%)
can no.
weight of air dried soil + can
weight of oven dried soil + can
weight of can
water content of soil specimen(air dried) (%)
Dry unit weight of soil specimen (lb/ft3)
Specific gravity of soil
Volume of solids
Volume of voids
Void ratio, e, of soil specimen

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

28

Coefficient Of Permeability by Falling Head Method

Test
No.

h1

h2

(cm)

(cm)

Test
duration,
t

Temperature
of water,
T

(sec)

(oC)

permeability
at T (oC),
KT
(cm/s)

Ratio of
viscosity at
ToC/Viscosity
at 20oC

Permeability at
20oC,
k20
(cm/s)

Calculation
The coefficient of permeability is calculated from the following equation,
aL h1
k
ln C
At h2
Result
The coefficient of permeability of the given fine-grained soil by Falling Head
Permeability test is found to be, k20 oC =________ __________cm/s.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

29

Direct Shear Test

4
DIRECT SHEAR
TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

30

Direct Shear Test

4.1

INTRODUCTION

Shear strength may be estimated by measuring the resistance offered against sliding friction
at the interface of two surfaces or layers within granular materials. According to MohrCoulomb theory a soil will fail at shear stress greater than or equal to
= c + tan
This can be represented graphically by developing failure envelope(s) named after Mohr and
Coulomb.
Where,
= shear stress
c = cohesion
= Angle of internal friction
= Normal or vertical stress

Chart 4.1 Normal Stresses vs. Shear Stress


Direct shear test used to be much popular in geotechnical investigations but now is not being
used extensively as more precise and reliable shear measurement techniques (Triaxial tests)
have been developed and introduced as standard methods. The other reasons for limited use
of direct shear test are:
1. The area of the sample changes as the test progresses, but may not be very significant
as most samples fail at low deformations.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

31

Direct Shear Test

2. The actual failure surface is not plane, as is assumed or as was intended the way shear
box was designed, nor is the shearing stress uniformly distributed over the failure
surface, as is assumed when performing calculations.
3. The test uses a small sample that makes test susceptible to errors when preparing
specimen (i.e. difficult to obtain a representative sample).
4. The size of the sample precludes much investigation into pore water during the test
(drained and undrained conditions)
5. Values of the modulus of the elasticity and Poissons ratio cannot be determined.

4.1.1

DEFINITIONS

RELATIVE LATERAL DISPLACEMENT


Relative lateral displacement the horizontal displacement of the top and bottom shear box
halves relative to each other.

FAILURE
The stress condition at failure for a test specimen. Failure corresponds to the maximum shear
stress attained or the shear stress at 15-20 percent relative lateral displacement. Depending on
soil behavior and field application, other suitable criteria may be defined.

SHEAR STRENGTH
Maximum shear stress that can be sustained by a material before rupture is called shear
strength. It is the ultimate strength of a material subjected to shear loading.

COHESION
It is the soils inter-particle attraction which ultimately provides resistance to sliding of
particles one over the other.

4.2

OBJECTIVES OF TEST

This experiment is used to determine the internal angle of friction for a fine, dry sand by
means of a shear box apparatus.

4.3

SCOPE OF TEST

Direct shear test is used to predict the value of the angle of internal friction and cohesion of
the soil parameters quickly. The laboratory report covers the laboratory procedures for
determining these values for cohesion less soils.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

32

Direct Shear Test

4.4

STANDARD REFERENCE

ASTM D3080-72

4.5
1.
2.
3.
4.
5.
6.
7.
8.
9.

MATERIALS & EQUIPMENT


Direct shear box apparatus
Loading frame (motor attached).
Dial gauge.
Proving ring.
Tamper.
Straight edge.
Balance to weigh up to 200 mg.
Aluminum container.
Spatula.

Figure 4.1 Direct shear devices and shear box

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

33

Direct Shear Test

4.6

PREPARATION OF SAMPLES AND TEST SPECIMEN

Test specimen can be prepared by mixing water in sand and carefully put it in mould in
layers with the help of wooden tamper.

4.7

TEST PROCEDURE

1.
2.
3.
4.

Check the inner dimension of the soil container.


Put the parts of the soil container together.
Calculate the volume of the container. Weigh the container.
Place the soil in smooth layers (approximately 10 mm thick). If a dense sample is
desired tamp the soil.
5. Weigh the soil container, the difference of these two is the weight of the soil.
Calculate the density of the soil.
6. Make the surface of the soil plane.
7. Put the upper grating on stone and loading block on top of soil.
8. Measure the thickness of soil specimen.
9. Apply the desired normal load.
10. Remove the shear pin.
11. Attach the dial gauge which measures the change of volume.
12. Record the initial reading of the dial gauge and calibration values.
13. Before proceeding to test check all adjustments to see that there is no connection
between two parts except sand/soil.
14. Start the motor. Take the reading of the shear force and record the reading.
15. Take volume change readings till failure.
16. Add 5 kg normal stress 0.5 kg/cm2 and continue the experiment till failure
17. Record carefully all the readings. Set the dial gauges zero, before starting the
experiment

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

34

Direct Shear Test

Figure 4.2 Cross-section of a direct shear box test

4.8

CALCULATIONS

1. Compute the shear stress as = Ph / A


2. Compute the normal stress as n = Pv / A
3. Compute the horizontal displacement, h, and the vertical displacement, v, for each
observed value.
4. Plot shearing stress against horizontal displacement and obtain the maximum value of
shearing stress, max.
5. Plot a graph of normal displacement vs. shear displacement. This should be on the
same page (same horizontal scale) as the shearing stress vs. shear displacement plot.
6. Using data from all three groups plot shearing stress against normal stress and show
the angle of internal friction, , and the intercept, c.

4.9

RESULTS

The shear strength parameters of the given soil sample tested in the laboratory are
c

kg/cm2,

degree

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

35

Direct Shear Test

Plot a graph of Shear Stress vs. Normal Stress. This graph will be approximately a straight
line. The y-intercept of this line gives the cohesion. And the angle of internal friction of the
soil can be determined from the slope of the straight-line. For purely cohesion less soil this
line passes through origin.

tan 1

`
n

4.10

ENGINEERING USES OF TEST RESULTS

Near any geotechnical construction (e.g. slopes, excavations, tunnels and foundations) there
will be both mean and normal stresses and shear stresses. The mean or normal stresses cause
volume change due to compression or consolidation. The shear stresses prevent collapse and
help to support the geotechnical structure. Failure will occur when the shear stress exceeds
the limiting shear stress (strength). The evaluation of shear parameters is quite important
before initiating any geotechnical construction.
In many engineering problems such as design of foundation, retaining walls, slab bridges,
pipes, sheet piling, the value of the angle of internal friction and cohesion of the soil involved
are required for the design. Direct shear test is used to predict these parameters quickly. The
laboratory report covers the laboratory procedures for determining these values for cohesion
less soils.

4.11
1.
2.
3.
4.

PRECAUTIONS
Preparation of sample should be carried out properly.
Sample must be placed in the mould carefully.
Each time mould should be properly cleaned with brush.
Care should be taken in handling the apparatus.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

36

Direct Shear Test

4.12

SAMPLE PROBLEM
GENERAL REPORT
DIRECT SHEAR TEST ON SAND
Sample No.___15____________________
Boring No. ______________B-21_______
Depth of sample ___________3 ft_______
Description of Sample Reddish Brown Clay
Tested by __________________________
Comments _________________________
Location ___________________________
Date ______________________________
Normal stress, n ___________________
Proving ring calibration factor __0.15____

Client Name ________________________


Company Name _____________________
Project Name _______________________
Project No. _________________________
Location of site _____________________
Date of sampling ____________________
Date of testing ______________________
Reporting Name ____________________
Weight of specimen, W ___25 gm______
Normal load, N _____________________
Horizontal
Displacement

Vertical
Displacement

(1)

(2)

No. of divisions
in proving ring
dial gauge
(3)
20
60
135

CALCULATIONS

Shear
Force,
S

Shear stress,

(4)
200.152.2
= 6.6
19.8
44.55

(5)
0.264
0.792
1.782

RESULTS

Graph
Plot a graph of shear stress vs. strain; determine the peak stress from the graph, If 20% strain
occurs before the peak stress, then the stress corresponding to 20% strain should be taken as
Shear strength and not the peak shear strength.
Plot a graph of Shear Stress vs. Normal Stress. This graph will be approximately a straight
line. The y-intercept of this line gives the cohesion. And the angle of internal friction of the
soil can be determined from the slope of the straight-line. For purely cohesion less soil this
line passes through origin.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

37

Direct Shear Test

`n

tan 1

Shear stress

, (kg/cm2)

300
250
200

150
100
50
0
0

10

15

Normal stress n, (kg/cm2)


Result
C=
=

(kg/cm2)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

38

Direct Shear Test

GENERAL REPORT
DIRECT SHEAR TEST ON SAND
Client Name ________________________
Company Name _____________________
Project Name _______________________
Project No. _________________________
Location of site _____________________
Date of sampling ____________________
Date of testing ______________________
Reporting Name ____________________
Weight of specimen, W ______________
Normal load, N _____________________
Horizontal
Displacement

Vertical
Displacement

(1)

(2)

Sample No._________________________
Boring No. _________________________
Depth of sample _____________________
Description of Sample ________________
Tested by __________________________
Comments _________________________
Location ___________________________
Date ______________________________
Normal stress, ___________________
Proving ring calibration factor __________
No. of
divisions in
proving ring
dial gauge
(3)

Shear
Force,
S

Shear stress,

(4)

(5)

RESULTS

CALCULATIONS

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

39

Direct Shear Test

Displacement

D/R

Horizontal
displacement
D/R L.C

Corrected area
A0=A-BH

Load
D/R

Load
S.F=D/RL.C

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

shear stress
=S.F/A0

40

Direct Shear Test

Graph
Plot a graph of Shear Stress vs. Normal Stress. This graph will be approximately a straight
line. The y-intercept of this line gives the cohesion. And the angle of internal friction of the
soil can be determined from the slope of the straight-line. For purely cohesion less soil this
line passes through origin.

tan 1
`n
Result
C=
(kg/cm2)
=

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

41

One Dimensional Consolidation Test

5
ONE
DIMENSIONAL
CONSOLIDATION
TEST
Balochistan University of of Information Technology Engineering & Management Sciences
(BUITEMS), Quetta

42

One Dimensional Consolidation Test

5.1

INTRODUCTION

This test method covers procedures for determining the magnitude and rate of consolidation
of soil when it is restrained laterally and drained axially while subjected to incrementally
applied controlled-stress loading.
This test method is most commonly performed on undisturbed samples of fine grained soils
naturally sedimented in water, however, the basic test procedure is applicable, as well, to
specimens of compacted soils and undisturbed samples of soils formed by other processes
such as weathering or chemical alteration. Evaluation techniques specified in this test method
are generally applicable to soils naturally sedimented in water. Tests performed on other soils
such as compacted and residual (weathered or chemically altered) soils may require special
evaluation techniques.
In case of consolidation settlement of a soil two issues are important i.e. (i) How much the
soil will settle under the application of a particular load and (ii) How long will it take in
settlement. For the latter one it is necessary to know the coefficient of consolidation Cv. To
determine Cv two approaches can be used, one the coefficient of permeability of a soil k, and
the coefficient of volume compressibility mv are known first, then by using
k
,
Cv
mv w
where
w is unit weight of water at an ambient temperature.
Plot a graph between Deformations versus Time; the time at different degrees of
consolidation is obtained and by using
2
Tv H dr
Cv
t
the value of Cv for a particular tested soil can be determined.
Where
Tv = Dimensionless time factor
Tv

for 0 U 60%
4 100

Tv = 1.78 - .933 log (100 U) For U > 60


U = Degree of Consolidation
Charts are also available for different values of Tv against respective values of
U.
d = Length of the longest drainage path in the soil sample.

1 Hi H f
H dr
2
2

Hi = Initial sample thickness

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

43

One Dimensional Consolidation Test

Hf = Sample thickness at complete consolidation under a Particular load


t = Time of interest obtained from deformation v/s. time curves.
In square root method where the graph is plotted between dial gauge reading
and square root of t , t 90 is used.
In logarithm method where graph is plotted between dial gauge reading and
Log (t), t50 is used.
In equation (i) the value T is put according to the value of t. If t = tu, then
T = TU. Where, U shows degree of consolidation

5.1.1

DEFINITIONS

PRE-CONSOLIDATION STRESS, P
This is the maximum stress that the soil has felt in the past.

COMPRESSION INDEX, CC
The compression index, CC, which indicates the compressibility of a normally-consolidated
soil.

RECOMPRESSION INDEX, CR
The recompression index, CR, which indicates the compressibility of an over consolidated
soil.

COEFFICIENT OF CONSOLIDATION, CV
The coefficient of consolidation, CV, which indicates the rate of compression under a load
increment.

NORMALLY-CONSOLIDATED SOIL
A normally-consolidated soil is defined as a soil which, at the present time, is undergoing the
application of a stress that is larger than any stress it has undergone in its history.
That is,
present n '

OVER-CONSOLIDATED SOIL
An over-consolidated soil is defined as a soil which has experienced higher stresses in the
past,
present p '

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

44

One Dimensional Consolidation Test

CONSOLIDATION
When soil is loaded undrained, the pore pressures increase. Then, under site conditions, the
excess pore pressures dissipate and water leaves the soil, resulting in consolidation
settlement. This process takes time, and the rate of settlement decreases over time.

5.2

OBJECTIVES OF TEST

The consolidation test is used to measure the settlement characteristics of a clay layer.

5.3

SCOPE OF TEST

Consolidation is an important fundamental phenomenon which must be understood by


everyone who attempts to gain knowledge of soil behavior in engineering applications. The
main purpose of consolidation tests is to obtain soil data which is used in predicting the rate
and amount of settlement of structures founded on clay. Although some of the settlement of a
structure on clay may be caused by shear strain; most of it is normally due to volumetric
changes. This is particularly true if the clay stratum is thin compared to the width of the
loaded area or the stratum is located at a significant depth below the structure.

5.4

STANDARD REFERENCE

ASTM: D2435-70
AASHTO: T216-66

5.5
1.
2.
3.
4.
5.
6.

MATERIALS & EQUIPMENT


Consolidometer
Specimen trimming device
Balance sensitive to 0.01 g
Stop watch
Moisture can
Oven

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

45

One Dimensional Consolidation Test

Figure 5.1 One dimensional consolidation apparatus

5.6

PREPARATION OF SAMPLES AND TEST SPECIMEN

1.
2.
3.
4.
5.
6.
7.
8.

Remove covering from sample.


Keep track of the sample orientation.
Place sample on wax paper disc and glass plate.
Rough cut the diameter with a wire saw to within 1/8" of final diameter.
Obtain water contents from trimmings
Assemble sample in trimmer with extension disc supporting soil.
Trim sample with cutting shoe and spatula, obtain second water content.
Once sample is completely fitted into specimen ring, trim top and bottom with
a
wire saw. Make final cut on top surface with a sharp straight edge.
9. Obtain third and fourth water contents.
10. Use recess tool to create space at top of ring and trim excess soil from bottom with
wire saw. Make final cut with the sharp straight edge.
11. Determine the mass of the specimen and ring (Ms+r).
12. Measure the recess from the top of ring to the soil surface (Hi)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

46

One Dimensional Consolidation Test

5.7
5.7.1

ADJUSTMENT AND CALIBRATION OF


INSTRUMENTS
APPARATUS CALIBRATION

1. Assemble the cell (stones, filter paper and top cap).


2. Align assembly in the loading frame.
3. Place a 1 lb seating load on the cell and obtain a zero reading on the displacement
transducer.
4. Apply the same loads to the apparatus as will be used in testing the specimen.
5. At each load increment, record the displacement reading at 15 sec, 30 sec, 1 min, 2
min and 5 min.
6. The change in dial reading gives the machine deflection curve.

5.7.2

APPARATUS PREPARATION

1. Assemble the Oedometer (stones, filter paper and top cap)


2. Measure the initial z3 (height between top of cap and specimen ring). You can place a
dummy specimen (block of known thickness) between the filter papers for added
height.
3. Disassemble the Oedometer.
4. Grease specimen ring and cutting shoe.
5. Determine the mass (Mr) of the empty specimen ring.
6. Measure the height (Hr) and diameter (Dr) of the ring.
7. Measure the thickness of one piece of filter paper (Hfp).
8. Cut two pieces of filter paper.
9. Boil or ultrasound the stones for 10 minutes to clean and remove air
10. Cut 2 wax paper disks the diameter of the specimen.

5.7.3

APPARATUS ASSEMBLY

1.
2.
3.
4.
5.
6.
7.

Fill base with water.


Insert bottom stone into base and cover with filter paper.
Remove excess water with a paper towel.
Place specimen and ring on stone.
Cover rim with gasket.
Tighten with locking ring.
Cover specimen with filter paper and top stone, allow this stone to drain before
placing on soil.
8. Place top cap on stone.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

47

One Dimensional Consolidation Test

9. Measure z3 with specimen


10. Locate assembly in loading frame with dial gauge and balance arms (this is the true
weight of the assembly which is the tare load).
11. Apply one pound seating load and zero displacement transducer.

5.8

TEST PROCEDURE

1. Consolidate the specimen using a load increment ratio (P/P) between 0.5 and 1.0 for
loading and -0.25 and -0.50 for unloading. Note: recommended schedule S, 0.125,
0.25, 0.5, 1.0, 2, 4, 8, 4, 1, S.
2. Fill the water bath at about 1/4 the overburden stress (0.25 ksi) or within 2 hours.
3. For each increment, record the displacement transducer reading versus time.
Remember that the initial portion of the curve is very important to define the start of
consolidation (s).
4. During each increment plot both root time and log time curves.
5. Apply increments after the end of primary consolidation has been reached.
6. Allow one cycle of secondary compression to occur under the maximum load and
before the unload-reload cycle.
7. At the end of the test unload the specimen to the seating load and allow time for
swelling.
8. Remove the water from the bath and remove the specimen from the apparatus.
9. Remove any extruded soil and oven dry.
10. Dry the surface of the specimen and determine the mass of both soil and ring.
11. Extrude the soil and obtain water content.
12. Collect washings from filter paper and inside of ring and oven dry.

5.9

CALCULATIONS

Initial Specimen Height = Hr Hi - Hfp


Water Content = (total mass - dry mass)/ dry mass
Note: compute the total mass during the test by subtracting (axial deformation X Area X unit
weight of water) from initial wet mass. This assumes that only water comes out of the
specimen during consolidation.
Void Ratio = (total volume - volume of solids)/ volume of solids
Volume of solids = mass of oven dried soil / specific gravity
Degree of saturation = specific gravity water content / void ratio

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

48

One Dimensional Consolidation Test

Vertical effective stress ('v) (when the pore pressure is zero) = (Applied load - Tare load +
top cap and stone)/ Area
Vertical strain (v) = (measured axial deformation - Apparatus compression)/ Initial specimen
height
Note: The Apparatus compression curve is attached to this assignment
Compressibility (av) = - change in void ratio / change in vertical stress
Note: change in void ratio is usually taken at the end of primary but for this laboratory
assignment you can use end of increment values.
2

Coefficient of consolidation (CV). (Root time) = 0.848 (drainage height) / time for 90%
consolidation
2

Coefficient of consolidation (CV). (Log time) = 0.197 (drainage height) / time for 50%
consolidation
Note: Drainage height is computed at 50% consolidation for both cases.
Hydraulic conductivity (kV) = (coefficient of consolidation compressibility unit weight
of water) / (1 + average void ratio)
Rate of secondary compression (c) = change in strain per log cycle of time after primary is
complete

Square root or time vs. Dial gauge reading

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

49

One Dimensional Consolidation Test

5.10

RESULTS

The value of coefficient of consolidation is found to be _________


By square root method _________

5.11

ENGINEERING USES OF TEST RESULTS

In engineering practice, reasonably good predictions of a structures settlements can be made


from the results of carefully run laboratory tests. Predicted settlements are larger than actual
settlements more often than not. Time rate predictions are often rather poor in practice. Better
predictions, naturally, can be made for those cases which have conditions more closely in
agreement with the assumptions made in the theory derivation. This would be the case, for
example, when the soil involved experiences most of its settlement due to primary
consolidation, or when drainage conditions in the field are accurately known.

5.12

PRECAUTIONS

1. Handling of instrument must be with care.


2. Readings should be note down carefully.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

50

One Dimensional Consolidation Test

5.13

SAMPLE PROBLEM

GENERAL REPORT
CONSOLIDATION TEST
(Time vs. vertical dial reading)
Client Name ________________________ Sample No. _________B-24___________
Company Name _____________________ Boring No. _________________________
Project Name _______________________ Depth of sample ____2 ft______________
Project No. _________________________ Description of Sample _____silty_______
Location of site _____________________ Tested by __________________________
Date of sampling ____________________ Comments. _________________________
Date of testing ______________________ Location ___________________________
Reporting Name ____________________
Date ______________________________
Pressure on specimen ________________
Clock time of load application __________
Time after load
Vertical dial
1/2
application
(t)
reading
t
(min)
(min 0.5)
(in)
9:15 AM
0
0
09:15.1
0.1
0.316228
9:15:25
0.25
0.5
09:15.5
0.5
0.707107
9:16
1
1
9:17
2
1.414214
9:19
4
2
9:23
8
2.828427
9:30
15
3.872983
9:45
30
5.477226
10:15
60
7.745967
11:15
120
10.95445
1:15 PM
240
15.49193
5:15
480
21.9089
8:15 AM
1380
37.14835
CALCULATIONS
RESULT

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

51

One Dimensional Consolidation Test

GENERAL REPORT
CONSOLIDATION TEST
(Void ratio-pressure and coefficient of consolidation calculation)
Client Name ________________________
Company Name _____________________
Project Name _______________________
Project No. _________________________
Location of site _____________________
Date of sampling ____________________
Date of testing ______________________
Reporting Name ____________________
Specimen diameter __________________
Moisture content: beginning of test __ (%)
Weight of dry soil specimen ___________
Pressure
P
(T/ft2)

Final
Dial
Reading

Change
in
specimen
height

(in)
(in)

CALCULATIONS

Final
specimen
Height
Ht(f)
(in)

Sample No._________________________
Boring No. _________________________
Depth of sample _____________________
Description of Sample ________________
Tested by __________________________
Comments _________________________
Location ___________________________
Date ______________________________
Initial specimen height, Ht(i)___________
Moisture content: End of test ________(%)
Gs ___ Height of solids, Hs_________ cm

Height
of void

Final
void
ratio

Hv
(in)

Average
height during
consolidation,
Ht(av)
(in)

Fitting time
(sec)

cv from
x
103(in2/sec)

t90

t90

t50

t50

RESULTS

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

52

One Dimensional Consolidation Test

Dial Readings vs Time

Deformation dial reading

Time (min)
0
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016 0.1
0.018

10

100

1000

10000

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

53

One Dimensional Consolidation Test

SOIL TESTING LABORATORY


CONSOLIDATION TEST
(Void ratio-pressure)
Void Ratio
Initial void ratio, eo

1.248781

Volume of solid in specimen, Vs

27.90809

Area of specimen, A (cm2)

31.67736

Height of solid in specimen, Hs (cm)

0.881011

Pressure,
P(tons/ft2)

Initial
deformation
dial reading at
beginning of
first loading(in.)

Deformation dial
reading
representing
100% primary
consolidation, (in.)

Change in thickness of
specimen, H(cm)

(8)=((7)-(6))*2.54

(9)=(8)/(4)

(10)=(1)-(9)

0
0.4
0.8
1.6
3.2
6.4
12.8

0
0
0
0
0
0
0

0
0.0158
0.0284
0.049
0.0761
0.1145
0.158

0
0.04013
0.07214
0.12446
0.19329
0.29083
0.40132

0
0.04555
0.08188
0.14127
0.2194
0.33011
0.45553

1.25
1.204447
1.16812
1.108729
1.030597
0.919886
0.794472

Change in
Void Ratio,
void ratio, De
e (e=eo-e)
[e=H/ Hs]

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

54

One Dimensional Consolidation Test

(Coefficient of consolidation calculation)


Initial
Deformation Thickness of
Half
height of
dial reading
specimen at
thickness of
Pressure, specimen
at 50%
50%
specimen at
P,
at
consolidation consolidation,
50%
2
(tons/ft ) beginning
consolidation
of test, Ho
(in)
(in)
(in)
(in)
(3)
(from dial
(4)=(2)-(3)
(5)=(4)/2
(1)
(2)
reading vs
log of time
curves)

Time for 50%


consolidation
(min)

Coefficient of
consolidation
(in2/min)

(6)
(from dial
readings
versus log of
time curves)

(7)=0.196(5)2/(6)

0.78

0.4

0.78

0.0108

0.7692

0.3846

8.2

0.003536

0.8

0.78

0.0233

0.7567

0.37835

6.4

0.004384

1.6

0.78

0.0398

0.7402

0.3701

0.006712

3.2

0.78

0.0644

0.7156

0.3578

3.4

0.00738

6.4

0.78

0.0982

0.6818

0.3409

3.5

0.006508

12.8

0.78

0.1387

0.6413

0.32065

0.005038

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

55

One Dimensional Consolidation Test

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

56

One Dimensional Consolidation Test

Result
The value of coefficient of consolidation is found to be
By square root method =
By logarithm method =

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

57

One Dimensional Consolidation Test

SOIL TESTING LABORATORY


CONSOLIDATION TEST
Specimen Data
At beginning of test
Type of specimen(checked one)
undisturbed
remolded
Diameter of specimen, D( in.)
Area of specimen , A in.2
Initial height of specimen, Ho ( in.)
Initial volume of specimen (in.3)
Weight of specimen ring +specimen (g)
Weight of specimen ring (g)
Initial wet weight of specimen (g)
Initial wet unit weight
Initial moisture content (%)
Can no.
Weight of wet soil + can (g)
Weight of dry soil + can (g)
Weight of can (g)
Weight of water (g)
Weight of dry soil (g)
Initial moisture content (g)
Initial dry weight of specimen (computed) (g)
Specific gravity of soil

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

58

One Dimensional Consolidation Test

Volume of solid in soil specimen cm3


Volume void in soil specimen cm3
volume of water in soil specimen cm3
(Note: Unit weight of water = 1 g/cm3)
Initial degree of saturation
At the End of test
Can no.
Weight of can + wet specimen removed from
Consolidometer (g)
Weight of can + oven dried specimen (g)
Weight of can (g)
Final weight of water in specimen
Final dry weight of specimen
Final moisture content
Final degree of saturation %
Initial void ratio
Volume of solid in specimen cm3
Initial volume of specimen cm3
Initial volume of void in specimen cm3
Initial void ratio, eo

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

59

One Dimensional Consolidation Test

(Time vs. vertical dial reading)


Pressure on specimen
Clock time of load application
Time after load application
t
(min)

(t)1/2
(min 0.5)

Vertical dial
reading
(in)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

60

One Dimensional Consolidation Test

SOIL TESTING LABORATORY


CONSOLIDATION TEST
(Void ratio-pressure)
Void Ratio
Initial void ratio, eo
Volume of solid in specimen, Vs
Area of specimen, A (cm2)
Height of solid in specimen, Hs (cm)

Pressure,
P
(tons/ft2)

Initial
deformation dial
reading at
beginning of
first loading
(in)

Deformation dial
reading
representing
100% primary
consolidation,
(in)

(5)

(6)

(7)

Change in thickness
of specimen,
H
(cm)
(8)=((7)-(6))2.54

Change in void
ratio,

e (e=eo-e)
De [e=H/ Hs]

(9)=(8)/(4)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

Void Ratio,

(10)=(1)-(9)

61

One Dimensional Consolidation Test

(Coefficient of consolidation calculation)

Pressure,
P,
(tons/ft2)

(1)

Initial height of
specimen at
beginning of
test, Ho
(in)
(2)

Deformation
dial reading at
50%
consolidation
(in)
(3)
(from dial
reading vs log of
time curves)

Thickness of
specimen at
50%
consolidation,
(in)
(4)=(2)-(3)

Half thickness
of specimen at
50%
consolidation
(in)

Time for 50%


consolidation
(min)

Coefficient of
consolidation
(in2/min)

(5)=(4)/2

(6)
(from dial
readings versus
log of time curves)

(7)=0.196(5)2/(6)

Result
The value of coefficient of consolidation is found to be
By square root method =
By logarithm method =

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

62

Standard Penetration Test

6
STANDARD
PENETRATION
TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

63

Standard Penetration Test

6.1

INTRODUCTION

If the test is to be carried out in gravelly soils the driving shoe is replaced by a solid 600 cone.
There is evidence that slightly higher results are obtained in the same material when the
normal driving shoe is replaced by the 600 cone.
The Standard Penetration Test was developed around 1927. It is estimated that 85% to 90%
of conventional foundation design in North and South America is made using the SPT. This
dynamic penetration test is used to assess the density index and to determine the bearing
capacity of a sand deposit. This dynamic penetration test is used to assess the density index
and to determine the bearing capacity of a sand deposit.
The test is performed using a split barrel sampler, 50 mm external diameter, 35 mm internal
diameter and about 450 mm (18in) in length, connected to the end of boring rods. The
sampler is driven into the sand at the bottom of a cased borehole by means of 65 kg hammer
falling freely through a height of 760 mm (30 in) onto the top of the boring rods.

Figure 6.1 Arrangement of SPT

Different methods of releasing the hammer are used in different countries. The borehole must
be cleaned out to the required depth, care must be taken to ensure that the material to be
tested is not distributed: jetting, as part of the boring operation is undesirable. The casing
must not be driven below the level at which the test is to begin.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

64

Standard Penetration Test

Initially the sampler is driven 150mm (6in) into the sand to seat the device and to bypass any
disturbed sand at the bottom of the borehole. The number of blows required to drive the
sampler a further 300 mm (12in) is then recorded: this number is called the standard
penetration resistance (N). The number of blows required for each 150 mm (6in) of
penetration (including the initial drive) should be recorded separately. If 50 blows are
reached before a penetration of 300mm (12in), no further blows should be applied but the
actual penetration should be recorded. At the conclusion of a test the sampler is withdrawn
and the sand extracted. Tests are normally carried out at interval of b/w 0.75 and 1.5m to a
depth below foundation level at least equal to the width (B) of the foundation

6.2

OBJECT OF TEST

To determine the load bearing capacity of soils by standard penetration test. The object of the
test is to determine the relative density and bearing capacity of granular sandy soils.

6.3

SCOPE OF TEST

This test method describes the procedure, generally known as the Standard Penetration Test
(SPT), for driving a split-barrel sampler to obtain a representative soil sample and a measure
of the resistance of the soil to penetration of the sampler.
This standard does not purport to address all of the safety problems, if any, associated with
its use. It is the responsibility of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory limitations prior to use.

Figure 6.2 Equipment as mentioned under heading

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

65

Standard Penetration Test

6.4

STANDARD REFERENCE

ASTM: D1586

6.5

MATERIALS & EQUIPMENT

The test equipment consists of:


1. Standard split-barrel Sampler (Split-spoon)
2. A casing or Drilling.
3. A thick wall Split tube Sampler, with 2 (5.08cm) OD and 1.5 (3.5cm) ID having the
tube length of 18 to 24 long.
4. Guide rod. (30 or 76cm length)
5. Hammer having weight of 140lb (623N)
6. Rope.
7. Tripods
8. Steel chain (3m approx)
9. Lever support and rod
10. Pipe wrench and chain wrench
11. Pulley

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

66

Standard Penetration Test

Figure 6.3 Solid tube sampler and driving sample

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

67

Standard Penetration Test

6.6

TEST PROCEDURE

1. Attach the Standard split-barrel Sampler (Split-spoon) to the bottom of the drilling
rod. The top of the drilling rod is attached by anvil used to transfer the hammer load
to the drilling rod. The anvil connects a guide rod passing through the drop hammer.
2. Erect the tripod so that each leg must form an angle of 1200 with respect to the other
and at equidistant from the center mark. Hookup pulley to the tripod with a rope
passing over it, and connect one end of the rope with drop hammer to lift it up.
3. Excavate a circular or rectangular trench upto the required foundation depth (below
which the bearing capacity of the soil is required) at the center mark..
4. Gradually pull the other end of the rope (manually or by some mechanical
arrangements) to erect the sampler. Make sure that the sampler assembly is vertically
erected at the center mark of the testing spot in excavation.
5. Now pull the rope slowly to lift the drop hammer to the full height of the guide rod
(76cm approximately) and then suddenly release the rope to provide free fall to the
hammer repeatedly to drive the Standard split-barrel Sampler (Split-spoon) 18" into
the soil.
6. After driving the sampler 18" into the soil count the number of blows, which are
required to penetrate each of three 6" increments separately. The Standard Penetration
Resistance value (N-value) is the number of blows required to penetrate the last 12",
thus the N-value represents the number of blows per foot.
7. After blow counts have been obtained, remove and open the splitspoon Sampler to
obtain a disturbed sample for subsequent examination and testing.
8. Determine the specific weight of the soil on the spot of the boring log to obtain the
effective overburden pressure.

6.7

CALCULATIONS

Relation between N and


Corrected N

5
28.5

(peck, 1974)
10
30

15
32

20
33

25
35

30
36

35
37.5

40
39

45
40

50
43

Allowable bearing capacity using N-values

6.7.1

TERZAGHI AND PECK METHOD

Terzaghi and Peck (1948) recommended that N values should be determined between
foundation level and a depth of approximately B below the foundation. They proposed a
correlation between allowable bearing capacity and the corrected N-values in the form of a
chart. The breadth of footing and the corrected N-value are used as entry data and the

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

68

Standard Penetration Test

allowable bearing capacity (qTP) is read off the left vertical axis. For Correction there is also
a formula, which is given as follow:
2000
C N 0.77 log

`
The effect of the water table may be taken into account by applying the following correction

Cw

Dw
1
1

2 D B

Where
Dw = Depth of water table below the surface.
D = Foundation depth below the surface.
B = Footing breadth.
Thus,

q a C w qTP
The Terzaghi and Peck method yields quite conservative values of qa, since it attempts to
ensure that the settlement is nowhere greater than 25mm, for wide footings and rafts the
limiting values may be raised to 50 mm. The qTP value is the function of SPT resistance value
N, and the breadth of footing. The required graph can be found in any Soil Mechanics Text
Book.

6.7.2

MEYERHOF METHOD

Meyerhof (1965) suggested that the qTP value could be increased by 50 % and that no
correction should be made for the water table since the effect would be incorporated in the
measured N-values. Meyerhof also proposed a set of simple design relationships as follows:
s N
qa L
for B1.25m
1.9
2
sL N B 0.33
qa
for B 1.25m
2.84 B

qa

sL N
2.84

for rafts :

Where
SL = permitted settlement limit (mm).
N = average N-values between z = D and z = D + B.
B = breadth of footing.

6.7.3

BURLAND AND BURBIDGE METHOD

Burland and Burbidge (1985) using a large number of settlement observations concluded that
the depth of the zone of influence must be considered in which 75% of the settlement will
occur and which may be taken approximately as:

Z i e 0.77 ln B
Balochistan University of of Information Technology Engineering & Management Sciences
(BUITEMS), Quetta

69

Standard Penetration Test

Thus the average measured N-value is therefore taken between Z = D and Z = D + Zi


The compressibility of soil is stated in terms of average N-value as a grade of compressibility
and compressibility index as follow

Ic

1.71
N 1.4

The allowable bearing capacity of soil is thus will be given as follow

qa

SL

`
B 0.7 I c 3

` is the effective overburden pressure measured from top surface to the depth of foundation.

6.8

RESULTS

SL = ____________,
B = _____________,
Nav = ___________

No.
1
2
3

Method

Bearing Capacity

Average

Terzaghi and Peck


Meyerhof
Burland and Burbidge

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

70

Standard Penetration Test

6.9

SAMPLE PROBLEM
SOIL TESTING LABORATORY
STANDARD PENETRATION TEST

Sample No.
15
Boring No.
B-21
Depth of sample
3 ft
Description of Sample
Reddish brown silty clay
Tested by
John Doe
Specimen diameter
cm
Depth (z)
1st

Blows

2nd

16

per 6

3rd

27

16 + 27=43

(KN/m2)

19

z (KN/m2)

20.27

u z w

` u (KN/m2)

20.27

No.

Date

1/26/89

1.536

N` =CN N

66.027

Average: N

66.027

SL = 25.1
B=
1.06
Nav = 66

SR 2828
Newell, N.C

3.5 (1.07m)

No. of

2000
C N 0.77 log

Project No.
Location

mm
m

Method

Bearing Capacity

Terzaghi and Peck

1320 KN/m2

Meyerhof

882.6 KN/m2

Burland and Burbidge

Average
2485.8KN/m2

5254.9 KN/m2)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

71

Standard Penetration Test

SOIL TESTING LABORATORY


STANDARD PENETRATION TEST
Sample No.
Boring No.
Depth of sample
Description of Sample
Tested by
Specimen diameter

Project No.
Location

Date
cm

Depth (z)
No. of

1st

Blows

2nd

per 6

3rd
N

z
u z w

` u
CN =
2000
0.77 log

N` =CN N
Aver: N
Result
SL =
B=
Nav =

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

72

Unconfined Compression Test

7
UNCONFINED
COMPRESSION
TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

73

Unconfined Compression Test

7.1

INTRODUCTION

When the method of testing tube-recovered cohesive soil sample compression was first
introduced, it was widely accepted as a means of rapidly evaluating the shear strength of a
soil. From Mohrs circle construction; it is evident that the shear strength or cohesion of a
soil sample can be approximate where qu is always used as the symbol for the unconfined
compressive strength of the soil. This computation is based on the fact that the minor
principal stresses 3 are zero (atmospheric), and the angle of internal friction of the soil is
assumed zero. With more knowledge concerning soil behavior available, it became evident
that the unconfined compression test does generally provide a very reliable value of soil
shear strength for at least three reasons:
1. The effect of lateral restraint provided by the surrounding soil mass on the sample is
lost when the sample is removed from the ground. There is, however, some opinion
that the soil moisture is provides a surface tension (or confining) effect so that the
sample is somewhat confined. This effect should be more pronounced if the sample
is saturated or nearly so. This effect will depend also on the relative humidity of the
testing area making a quantitative evaluation of it rather difficult.
2. The internal soil condition (the degree of saturation, the pore water pressure under
stress deformation, and the effects of altering the degree of saturation) cannot be
controlled.
3. The friction on the end of the sample from the loading platens provides a lateral
restraint on the ends, which alters the internal stresses, an unknown amount.
Table 7.1 Relative consistency as a function of unconfined compressive strength
Consistency
qu (lb/ft2)
Very soft
<250
Soft
250-500
Medium
5000-1000
Stiff
1000-2000
Very stiff
2000-4000
Hard
>4000

7.1.1

DEFINITIONS

UNCONFINED COMPRESSIVE STRENGTH


The compressive stress at which an unconfined cylindrical specimen of soil will fail in a
simple compression test. In this test method, unconfined compressive strength is taken as the
maximum load attained per unit area or the load per unit area at 15% axial strain, whichever
is secured first during the performance of a test.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

74

Unconfined Compression Test

SHEAR STRENGTH
The shear strength of soil is the resistance to deformation by continuous shear displacement
of soil particles or on masses upon the action of shear stress.
For unconfined compressive strength test specimens, the shear strength is calculated to be
of the compressive stress at failure.

7.2

OBJECTIVES OF TEST

This method determines the unconfined compressive strength (qu) of the soil sample.

7.3

SCOPE OF TEST

This test method covers the determination of the unconfined compressive strength of
cohesive soil in the undisturbed, remolded, or compacted condition, using strain-controlled
application of axial load.
This test method provides an approximate value of the strength of cohesive soils in terms of
total stresses.
This test method is applicable only to cohesive materials which will not expel bleed water
(water expelled from the soil due to deformation or compaction) during the loading portion
of the test and which will retain intrinsic strength after removal of confining pressures, such
as clays or cemented soils. Dry and crumbly soils, fissured or varved materials, silts, peats,
and sands cannot be tested with this method to obtain valid unconfined compressive strength
values.
This test method is not a substitute for AASHTO T 234-85 which is Strength Parameters of
Soils using Triaxial Compression.
The values stated in SI units are to be regarded as the standard. The values stated in inchpound units are approximate.

7.4

STANDARD REFERENCE

ASTM: D2166-66
AASHTO: 208-70

7.5
1.
2.
3.
4.

MATERIALS & EQUIPMENT


Unconfined compression testing machine (Triaxial Machine)
Specimen preparation equipment
Sample extruder
Balance

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

75

Unconfined Compression Test

Figure 7.1 Unconfined Compression Testing Device

7.6
7.6.1

PREPARATION OF SAMPLES AND TEST SPECIMEN


PREPARATION OF UNDISTURBED SAMPLE

1. Obtain a sample and using the wire saw and miter box, trim the ends parallel to each
other.
2. Place the sample in the soil lathe and trim it to a circular cross-section.
3. Reposition the sample in the miter box and cut it to a length of approximately 7 cm
by trimming both ends.
4. Measure the average length and diameter of the sample using the veneer caliper.
Weigh the sample.
5. Use the sample trimmings to determine water content of the clay.

7.6.2

PREPARATION OF REMOULDED SAMPLE

1. Remold the clay thoroughly.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

76

Unconfined Compression Test

2. Reform a cylindrical specimen using the sample former, taking care not to entrap air
in to the clay.
3. Extrude the sample from the mould and square its ends using the miter box.
4. Measure the sample as before.

7.7

ADJUSTMENT AND CALIBRATION OF


INSTRUMENTS

Standard Geotest unconfined compression machines are supplied with a double proving ring
or load cell and digital display which reads directly to 0.1 lbf or 1N and have a peak hold.
Proving ring models include a calibration chart in both pounds and SI units. Pounds will be
supplied unless SI units are specified. Strain is measured with a 1" travel (25mm on SI
versions) dial indicator. 2" (50mm) dial indicators or EDDIs can replace dial indicator as an
added option.

7.8

TEST PROCEDURE

1. Remolded specimens are prepared in the laboratory depending on the proctors data at
the required molding water content.
2. If testing undisturbed specimens retrieved from the ground by various sampling
techniques, trim the samples into regular triaxial specimen dimensions (2.8 x 5.6)
3. There will be a significant variation in strength of undisturbed and remolded samples.
4. Measure the diameter and length of the specimen to be tested
5. If curing the sample (treated soils), wrap the samples in a geotextile and then a zip
bag. Place the sample in a humidity room maintained at a relative humidity of 90%
6. Prior to testing, avoid any moisture loss in the sample, place on a triaxial base
(acrylic). The ends of the sample are assumed to be frictionless
7. The triaxial cell is placed above the sample and no confinement is applied
8. The rate of strain is maintained at 1.2700 mm/min as per ASTM specifications.
9. The data acquisition system collects real time data and the test is stopped when there
is a drop observed in the strain versus load plot

7.9

CALCULATIONS
Calculate the water contents, Axial load (P = Load Ring Reading x [Calibration of
load ring]), strain ( = L/L0 x 100%), instantaneous area (Ai = A0/(1- ), where is
in decimal format), and 1 = P/A.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

77

Unconfined Compression Test

7.10

RESULTS
Plot a graph of 1 or the deviator stress as ordinate vs. ez or vertical strain in % as
abscissa on Cartesian graph paper. Define qu at failure; this is s1 (peak).

Figure 7.2 Failure patterns typical of brittle specimen

7.11

ENGINEERING USES OF TEST RESULTS

1. The test results provide an estimate of the relative consistency of the soil as can be
seen in Table 6.1.
2. Almost used in all geotechnical engineering designs (e.g. design and stability
analysis of foundations, retaining walls, slopes and embankments) to obtain a rough
estimate of the soil strength and viable construction techniques
3. To determine Undrained Shear Strength or Undrained Cohesion (Su or Cu) = qu/2
4. The unconfined compression test is usually made on undisturbed samples. It is
reasonably simple and rapid to perform. It gives a very good measure of the shearing
strength of cohesive soils. In somewhat granular soil its application is limited, but it
does provide a good supplementary test for more complex strength tests.
5. The unconfined compression test is limited in that test conditions can be varied very
little. Hence, the test may provide a good measure of the in-situ strength, but may
provide only limited strength data, as the stress conditions change due to loading or
construction.

7.12
1.
2.
3.
4.
5.

PRECAUTIONS
Scale must be precise.
Width of groove must be accurate.
Depth of groove must be accurate.
Handle of turning pace should be done with care.
Length of closure should be of inch

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

78

Unconfined Compression Test

7.13

SAMPLE PROBLEM

SOIL TESTING LABORATORY


UNCONFINED COMPRESSION TEST
Sample No.
15
Project No.
Boring No.
B-21
Location
Depth of sample
3 ft
Description of Sample
Reddish brown silty clay
Tested by
John Doe
Date
Proving ring calibration factor
6000 (lb/in)
Specimen
deformatio
n = L
(in)

(1)
0
0.025
0.05
0.075
0.1
0.125
0.15
0.175
0.2

Vertical
strain
= L / L

(2)
0
0.004181
0.008361
0.012542
0.016722
0.020903
0.025084
0.029264
0.033445

Proving
ring dial
reading
[No. of
small
divisions]

Load =
(Col. 3)
calibration
factor
(lb)

(3)

(4)

0
0.0024
0.0058
0.0086
0.0116
0.015
0.0176
0.0208
0.0224

0
14.4
34.8
51.6
69.6
90
105.6
124.8
134.4

SR 2828
Newell, N.C

1/26/89

Corrected
area =

Stress =
(col.4)/(col.5)

A0
1

(lb/in2) or kPa

Ac

(in2)
(5)

(6)

4.91
4.930613
4.9514
4.972362
4.993503
5.014825
5.036329
5.058019
5.079896

0
2.920529
7.028316
10.37736
13.93811
17.94679
20.96765
24.67369
26.45723

Result
Plot a graph of s1 or the deviator stress as ordinate vs. ez or vertical strain in % as abscissa on
Cartesian graph paper. Define qu at failure; this is s1 (peak).

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

79

Unconfined Compression Test

Relationship between load per unit


area and unit strain

Load Per Unit Area


(lb/in2)

30
25
20
15
10
5
0
0

10

15

Unit Strain (in/in)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

80

Unconfined Compression Test

Sample No.
Boring No.
Depth of sample
Description of Sample
Tested by
Specimen
deformatio
n = L
(in)

SOIL TESTING LABORATORY


UNCONFINED COMPRESSION TEST
Project No.
Location

Vertical
strain
= L / L

Date
Proving
ring dial
reading
[No. of
small
divisions]

Load =
(Col. 3)
calibration
factor
(lb)

Corrected
area =

Stress =
(col.4)/(col.5)

A0
1

(lb/in2) or kPa

Ac

(in2)

Result
Plot a graph of s1 or the deviator stress as ordinate vs. or vertical strain in % as abcissa on
Cartesian graph paper. Define qu at failure; this is s1 (peak).

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

81

Triaxial Test

8
TRIAXIAL TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

82

Triaxial Test

8.1

INTRODUCTION

From an inspection of the triaxial apparatus, it is concluded that any soil pore-fluid state, from
a negative or vacuum state to a fully saturate state with an excess pore-fluid pressure, can be
obtained with this equipment. Drained or undrained conditions can be investigated. For a
drained test, as the load is applied to the soil specimen, one can allow the pore fluid to escape
by opening the appropriate valve. An undrained test can be performed by closing the soil
system to the atmosphere so that no pore fluid can escape during the test.

8.1.1

DEFINITIONS

UNCONSOLIDATED-UNDRAINE TEST
Which is also called the quick test (abbreviation commonly used are UU and Q test). This test
is performed with the drain valve closed for all phases of the test. Axial loading is commenced
immediately after the chamber pressure 3 is stabilized.

CONSOLIDATED-UNDRAINED TEST
Also termed consolidated-quick test or R test (abbreviated CU or R). In this test, drainage or
consolidation is allowed to take place during the application of the confining pressure 3.
Loading does not commence until the sample ceases to drain (or consolidate). The axial load
is then applied to the specimen, with no attempt made to control the formation of excess pore
pressure. For this test, the drain valve is closed during axial loading, and excess pore pressures
can be measured.

CONSOLIDATED-DRAINED TEST
Also called slow test (abbreviated CD or S). In this test, the drain valve is opened and is left
open for the duration of the test, with complete sample drainage prior to application of the
vertical load. The load is applied at such a slow strain rate that particle readjustments in the
specimen do not induce any excess pore pressure.
Since there is no excess pore pressure total stresses will equal effective stresses. Also the
volume change of the sample during shear can be measured.

8.2

OBJECTIVES OF TEST

Determination of shear parameters of soils by triaxial test.

8.3

SCOPE OF TEST

Scope of this test is to determine the shear parameters, strength-deformation characteristics


pore water pressure, etc.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

83

Triaxial Test

From an inspection of the triaxial apparatus, it is concluded that any soil pore-fluid state, from
a negative or vacuum state to a fully saturate state with an excess pore-fluid pressure, can be
obtained with this equipment. Drained or undrained conditions can be investigated. For a
drained test, as the load is applied to the soil specimen, one can allow the pore fluid to escape
by opening the appropriate valve. An undrained test can be performed by closing the soil
system to the atmosphere.

8.4

STANDARD DESIGNATION

ASTM: D2850-70
AASHTO: 234-70

Figure 8.1 Schematic diagram of triaxial test

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

84

Triaxial Test

8.5

MATERIALS & EQUIPMENT

1. Triaxial cell.
2. Strain controlled compression machine (Figure 7.1)
3. Specimen trimmer
4. Wire saw
5. Vacuum source
6. Oven
7. Evaporating membrane
8. Calipers
9. Rubber membrane
10. Membrane stretcher

Figure 8.2 Triaxial test device

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

85

Triaxial Test

Figure 8.3 Triaxial test apparatus

8.6
8.6.1

PREPARATION OF SAMPLES AND TEST SPECIMEN


PREPARATION OF UNDISTURBED SAMPLE

1. Obtain a sample and using the wire saw and miter box, trim the ends parallel to each
other.
2. Place the sample in the soil lathe and trim it to a circular cross-section.
3. Reposition the sample in the miter box and cut it to a length of approximately 7 cm by
trimming both ends.
4. Measure the average length and diameter of the sample using the veneer caliper.
Weigh the sample.
5. Use the sample trimmings to determine water content of the clay.

8.6.2

PREPARATION OF REMOULDED SAMPLE

1. Remold the clay thoroughly.


2. Reform a cylindrical specimen using the sample former, taking care not to entrap air in
to the clay.
3. Extrude the sample from the mould and square its ends using the miter box.
4. Measure the sample as before.

8.7
8.7.1

TEST PROCEDURE
PLACEMENT OF SPECIMEN IN THE TRIAXIAL TESTING MACHINE

1. Boil the two-porous stones to be used with the specimen.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

86

Triaxial Test

2.
3.
4.
5.

De-air the lines connecting the base of the Triaxial cell


Attach the bottom platen to the base of the cell
Place the bottom porous stone (moist) over the bottom platen.
Take a thin rubber membrane of appropriate size to fit the specimen tightly. Take a
membrane stretcher, which is a brass tube with an inside diameter of about in
(6mm) larger than the specimen diameter. The membrane stretcher can be connected
to a vacuum source. Fit the membrane to the inside of the membrane stretcher, and lap
the ends of the membrane over the stretcher. Then apply the vacuum. This will make
the membrane form a smooth cover inside the stretcher.
6. Slip the soil specimen to the inside of the stretcher with the membrane (step5) the
inside of the membrane may be moistened for ease of slipping the specimen in. Now
release the vacuum, and unroll the membrane-form the ends of the stretcher.
7. Place the specimen (step 6) on the bottom porous stone (which is placed on the bottom
platen of the Triaxial cell), and stretch the bottom end of the membrane around the
porous stone and bottom platen. At this time, place the top porous stone (moist) and
the top platen on the specimen, and stretch the top of the membrane over it. For
airtight seals, it is always a good idea to apply some silicone grease around the top and
bottom plates before the membrane is stretched over them.
8. Using some rubber bands, tightly fasten the membrane around the top and bottom
platens.
9. Connect the drainage line leading from the top platen to the base of the triaxial cell.
10. Place the Lucite cylinder from the top platen to the base triaxial cell on the base plate
to complete the assembly.
Note
1. In the Triaxial cell, the specimen can be saturated by connecting the drainage line
leading to the bottom of the specimen to a saturation reservoir. During this process, the
drainage line leading from the top of the specimen is kept open to the atmosphere. The
saturation of clay specimens takes a fairly long time.
2. For unconsolidated undrained test, if the specimen saturation is not required,
nonporous plates can be used instead of porous stones at the top and bottom of the
specimen.

8.7.2

UNCONSOLIDATED- UNDRAINED TEST

1. Place the Triaxial cell (with the specimen inside it) on the platform of the compression
machine.
2. Make proper adjustment so that the piston of the triaxial cell just rests on the top
platen of the specimen.
3. Fill the chamber of the triaxial cell with water. Applying a hydrostatic pressure, 3, to
the specimen through the chamber fluid. (Note: All drainage to and from the specimen
should be closed now so that drainage from the specimen does not occur).
4. Check for proper contact between the piston and the top platen on the specimen. Zero
the dial gauge of the proving ring and the gauge used for measurement of the vertical
compression of the specimen. Set the compression machine for a strain rate of about
0.5% per minute, and turn the switch on.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

87

Triaxial Test

5. Take proving ring dial readings for vertical compression intervals of 0.01inch
(0.254mm) initially. This interval can be increased to 0.02 inch (0.508mm) or more
later when the rate of increase of loads on the specimen decreases. The proving ring
readings will increase to a peak value and then may decrease or remain approximately
constant. Take about four to five readings after the peak point.
6. After completion of the test, reverse the compression machine and lower the triaxial
cell, and then shut off the machine. Release the chamber pressure, and drain the water
in the triaxial cell. Then remove the specimen and determine its moisture content.

8.8

CALCULATIONS

1. Compute the unit strain from the deformation readings as


2. ax = L/L0 and fill in the appropriate column of the data sheet. Also compute the
adjusted instantaneous area A = Ac/ (1-ax) and place this in the appropriate column
of the data sheet. The c subscript above refers to the fact that these should be the
dimensions not at the start of the test, but after consolidation of the specimen.
3. Compute the axial load using the load readings. If a load (proving) ring is used, the
load P is P = DR x load-ring constant where DR is the load-dial reading in units of
deflection. Put these data in the appropriate column of the data sheet.
4. Compute the principal stress difference
5. (1 - 3) = P/A and fill in the appropriate column of the data sheet.
6. Knowing that
7. 1 = 3 + (1 - 3)
8. Compute the principal stress ratio: 1/3

8.9

RESULTS

1. Draw a graph of the axial strain (%) vs. deviatory stress. From this graph, obtain the
value of at failure ( = f)
2. The minor principal stress on the specimen at failure is 3 (i.e. the chamber confining
pressure). Calculate the major principal stress at failure as

1 3
3. Draw a Mohrs circle with 1 and 3 as the major and minor principal stresses. The
radius of the Mohrs circle is equal to Su.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

88

Triaxial Test

16
Stress change lb/in2

14
12
10
8
6
4
2
0
0

6
8
Axial strain %

10

12

14

Chart 8.1 Showing stress vs strain curve

Chart 8.2 Showing results of triaxial test

8.10

ENGINEERING USES OF TEST RESULTS

Triaxial test is a soils laboratory test to determine shear strength parameters. The shear
strength of soil is needed to design foundation, slopes, tunnels, dams, and other geotechnical
systems. It is a most widely used technique of determining the shear strength of soils.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

89

Triaxial Test

The sample, which is cylindrical, is tested inside a Perspex cylinder filled with water under
pressure. The sample under test is enclosed in a thin rubber membrane to seal it from the
surrounding water. The pressure in the cell is raised to the desired value, and the sample is
then brought to failure by applying an additional vertical stress.
One of the major advantages of the triaxial apparatus is the control provided over drainage
from the sample. When no drainage is required (i.e. in undrained tests), solid end caps are
used. When drainage is required, the end caps are provided with porous plates and drainage
channels. It is also possible to monitor pore-water pressures during a test.

8.11

PRECAUTIONS

1. Limit the magnitude of the excess pore pressure by testing at a very slow strain rate, as
it is impossible to have a state of no excess pore pressure
2. A drain test can take up to a week. For this duration, membrane leaks, soil set up and
equipment corrosion can be significant.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

90

Triaxial Test

8.12

SAMPLE PROBLEM

SOIL TESTING LABORATORY


UNCONSOLIDATED UNDRAINED TRIAXIAL TEST
(Preliminary data)
Sample No.
15
Project No. SR 2828
Boring No.
B-21
Location
Newell, N.C
Depth of sample
3 ft
Description of Sample
Reddish brown silty clay
Tested by
John Doe
Date
1/26/89
Moist unit weight of specimen (beginning of test)
122.7
lb/ft3
Moisture content (end of test)
16.9
(%)
Dry unit weight of specimen
105.0
lb/ft3
Initial average length of specimen, Lo
5.82
cm
Initial average diameter of specimen, Do
2.50
cm
Initial area, Ao
4.91
cm2
Gs
2.78
Final degree of saturation
71.9
%
Cell confining pressure, 3
10.0
psi
Proving ring calibration factor
6000
lb/in

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

91

Triaxial Test

SOIL TESTING LABORATORY


UNCONSOLIDATED-UNDRAINED TRIAXIAL TEST
(Axial stress strain calculation)
Specimen
deformation
= L

Vertical
strain,
= L
L

Proving
ring dial
reading

(in)
(1)
0
0.005
0.01
0.015
0.02
0.025
0.05
0.075
0.100
0.125
0.150
0.175
0.200
.225

(2)
0
0.0009
0.0017
0.0026
0.0034
0.0043
0.0086
0.0129
0.0172
0.0215
0.0258
0.0301
0.0344
0.0387

(3)
0
0.0012
0.0025
0.0037
0.0053
0.0066
0.0140
0.0201
0.0256
0.0294
0.0321
0.0337
0.0331
0.0305

Piston Load,
col.3 x c.f
(calibration
factor)
(lb)

Corrected area
=
Ac = Ao /1
(in2)

(4)
0
7.2
15
22.2
31.8
39.6
84
120.6
153.6
176.4
192.6
202.2
198.6
183

(5)
4.91
4.91
4.92
4.92
4.93
4.93
4.95
4.97
5.00
5.02
5.04
5.06
5.08
5.11

Deviatory
Stress
= P/Ac
(lb/in2)
(6)
0
1.5
3
4.5
6.5
8
17
24.3
30.7
35.1
38.2
40
39
35.8

Result
1.
Draw a graph of the axial strain (%) vs. deviatory stress. From this graph, obtain the
value of at failure ( = f)
2. The minor principal stress on the specimen at failure is 3 (i.e. the chamber confining
pressure). Calculate the major principal stress at failure as

1 3

3. Draw a Mohrs circle with 1 and 3 as the major and minor principal stresses. The radius
of the Mohrs circle is equal to Su.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

92

Triaxial Test

Stress (lb/in2)

Axial Strain vs Stress


45
40
35
30
25
20
15
10
5
0
0

0.01

0.02

0.03

0.04

0.05

Axial Strain (in/in)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

93

Triaxial Test

SOIL TESTING LABORATORY


UNCONSOLIDATED UNDRAINED TRIAXIAL TEST
(Preliminary data)
Sample No.
Project No.
Boring No.
Location
Depth of sample
Description of Sample
Tested by
Date
Moist unit weight of specimen (beginning of test)
Moisture content (end of test)
Dry unit weight of specimen
Initial average length of specimen, Lo
Initial average diameter of specimen, Do
Initial area, Ao
Gs
Final degree of saturation
Cell confining pressure, 3
Proving ring calibration factor

cm
cm
cm2
%

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

94

Triaxial Test

SOIL TESTING LABORATORY


UNCONSOLIDATED-UNDRAINED TRIAXIAL TEST
(Axial stress strain calculation)
Cell confining pressure,3=
Specimen
Vertical
Proving ring Piston Load,
Corrected
Deviatory
deformation
strain,
dial reading
col.3 x c.f
area =
Stress
= L
= L
(calibration Ac = Ao /1 = P/A
L
factor)
(in)
(lb)
(in2)
(lb/in2)
(1)
(2)
(3)
(4)
(5)
(6)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

95

Plate Load Test

9
PLATE LOAD TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

96

Plate Load Test

9.1

INTRODUCTION

1. The test results reflect only the character of the soil located within a depth less than twice
the width of the bearing plate (corresponding to an isobar of one-tenth the loading
intensity at the test plate). Since the foundations are generally large, the settlement and
resistance against shear will depend on the properties of a much thicker stratum.
2. It is essentially a short duration test, and hence the test does not give the ultimate
settlement, particularly in the case of cohesive soils.
3. Another limitation is the effect of the size of foundation. For clay soils the ultimate
pressure for a large foundation is the same as that for the test plate. But in dense sandy
soils, the bearing capacity increases, with the size the foundation, and the test on smaller
size bearing plates tend to given conservative values.

EFFECT OF THE SIZE OF PLATE ON BEARING CAPACITY


As stated in limitation 3 above, the bearing capacity of sands and gravels increase with the
size of the footing. The relationship can be expressed as under
Bf
qf M N
Bp
In the above relation, M term includes the NC and Nq terms while N include N portion of
the bearing capacity equation. The above equation can also be solved graphically by using
more than one size plates

EFFECT OF SIZE OF PLATE ON SETTLEMENT


The settlement of a footing varies with its size. Terzaghi and peck have suggested the
following relationship b/w the settlement of plate (sp) and settlement of actual footing (sf) for
granular soils.
Bp( B 0.3 )
Sp sf

B( Bp 0.3 )

If s is the permissible settlement of the foundation, the maximum settlement of the largest
forting should be restricted to 4/3s. The corresponding settlement of the test plate (Sp) on
sand, soil is given by
Sp

Bp( B 0.3 )
4
.s

3
B( Bp 0.3 )

DETERMINATION OF BEARING CAPACITY


By extrapolating the plate load test data, one can use the following equation for all practical
purposes to determine the bearing capacity of soil.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

97

Plate Load Test

q f qp

Bf
Bp

Where
qf = bearing capacity of the actual footing
Bf = width of actual footing
qp = bearing capacity, obtained from the plate load test
Bp = width of plate
However, for clays, the bearing capacity is almost independent of the footing
size or the plate size.
qf = qb
For a c- soil, housel (1992) suggested the following expression:
Q = A q + P. S
Where
Q = total load on bearing area
A = contact area of footing or plate
P = perimeter of footing
q = bearing pressure beneath area A
S = perimeter shear

DETERMINATION OF SETTLEMENT
Settlement of prototype foundation can be estimated from the results of plate load test using
following equations, after Terzaghi (1948).
Bf

S f Sp
Bp

For clays and if the sand is like an elastic material, then the settlement can be calculated from

S p ap B p

1u2
Ip
E

Where
Sp = plate settlement
ap = applied stress
Bp = width or diameter of the of the plate
u = poisons ratio
E = elastic modulus
Ip = influence factor (0.82 for rigid plate)
The settlement of the real footing of width B is related to the plate settlement
by

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

98

Plate Load Test

or

2B
S f Sp
B Bp

2B
S f Sp

B 0.3

for sands

Where
Sf = settlement of a prototype foundation
Sp = settlement of square plate of 0.3 m by 0.3 m
Bf = width of prototype foundation
Bp = width of the plate
Bond (1961) has proposed the following equation for settlements


S f Bp
Sp

n 1

Where
n = coefficient depending on the types of soil
The value of index n can be determined by carrying out two or more plate
load tests on different size plates. In absence of test data the following values
of n can be adopted:
Clay:
0.03 to 0.05
Sandy clay:
0.0.8 to 0.10
Dense sand:
0.4 to 0.5
Medium to dense sand:
0.25 to 0.35
Loose sand:
0.20 to 0.25

9.1.1

DEFINITIONS

DEFLECTION
The amount of downward vertical movement of a surface due to the application of a load to
the surface.

RESIDUAL DEFLECTION
The difference between original and final elevations of a surface resulting from the
application and removal of one or more loads to and from the surface.

REBOUND DEFLECTION
The amount of vertical rebound of a surface that occurs when a load is removed from the
surface.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

99

Plate Load Test

BEARING CAPACITY
The pressure that a soil sample can sustain without failing is called the bearing capacity of
soil.

SOIL SETTLEMENT
The process of compression (reduction in the volume of voids) of soil due to the expulsion of
air, water or both from the voids as a result of increased loading (such as geostatic weight or
weight of structure above) is called soil settlement.

9.2

OBJECTIVES OF TEST

This experiment is used to determine the ultimate and or safe bearing capacity of the fullscale foundation.

9.3

SCOPE OF TEST

This method covers the making of non repetitive static plate load test on subgrade soils and
flexible pavement components, in either the compacted condition or the natural state, and is
intended to provide data for use in the evaluation and design of rigid and flexible type
airport and highway pavements.

9.4

STANDARD REFERENCE

ASTM: D1194
AASHTO T 222-81

9.5
9.5.1

MATERIALS & EQUIPMENT


FIELD TEST APPARATUS

The required field test apparatus is as follows


1. Load reaction equipment. Load reaction equipment consisting of a truck, trailer,
anchored frame, or similar device having a dead load of at least 25,000 lb.
2. Bearing plates. Bearing plates consisting of a 30-in., 24-in., and 18-in.-diameter steel
plate, each plate 1 in. thick. Aluminum alloy No. 24ST plates 1.5 in. thick may be
used in lieu of steel plates.
3. Jack. Hydraulic jack capable of applying loads of at least 25,000 lb.
4. Ball joint. A ball joint to be inserted between the jack and load reaction equipment or
between the jack and bearing plates to prevent eccentricity of loading.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

100

Plate Load Test

5. Load-measuring device. A load-measuring device consisting of either a hydraulic


gage on the jack, a steel proving ring, or load cell. All are satisfactory for measuring
applied load, but must be accurately calibrated.
6. Micrometers. Three dial micrometers, reading to 1/10,000 in., dial stems, and support.
7. Sand/plaster of Paris. Clean sand or plaster of Paris.
8. Cribbing. Cribbing of short pieces of hardwood or steel H- or I-beams.
9. Stopwatch.
10. Containers. Containers for undisturbed soil samples.
11. Consolidometer apparatus.
12. Cutting equipment. Necessary equipment for cutting an undisturbed specimen of the
soil into a consolidometer test ring.
13. Scales
14. Oven
15. Miscellaneous tools for making moisture-content determinations.

Figure 9.1 Plate load test apparatus

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

101

Plate Load Test

Figure 9.2 Schematic diagram of Plate load test

9.6

TEST PROCEDURE

The test pit width is made five times the width of the plate Bp. At the center of the pit, a
small square hole is dug whose size is equal to the size of the plate and the bottom level of
which corresponding to the level of the actual foundation (figure) the depth Dp of the hole
should be such that the loading to the plate may be applied with the help of a hydraulic jack.
The reaching of the hydraulic jack may be borne by either of the following two methods
a) Gravity loading plate form method
b) Reaction truss method
In the case of gravity loading method, plate form is constructed over a vertical column
resting on the rest plate, and the loading is done with the help of sand bags, stone or concrete
blocks. The general arrangement of the test set-up for this method is shown in the figure.
When load is applied to the plate, it sinks or settles. The settlement of the plate is measured
with the help of sensitive dial gauge. For square plate, two dial gauges are used. The dial

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

102

Plate Load Test

gauges are mounted on independently supported datum bar. As the plate settles, the ram of
the dial gauge moves down and settlement is recorded. The load is indicated on the loadgauge of the hydraulic gauge of the hydraulic jack.
5Bp

D
Dp

Bearing Plate

Foundation level

Bp

Sand bags

Plate form
Main girder
Hydraulic jack
Masonry support
Loading post
Dial gauges

Datum bar

Test plate

Figure 9.3 Schematic diagram of Plate load test


The load is applied with the help of a hydraulic jack (preferably with the remote control
pumping unit), in convenient increments, say of about one-fifth of the expected safe bearing
capacity or one-tenth of the ultimate bearing capacity. Dial gauges fixed at diametrically
opposite ends, with sensitivity of 0.02mm, observe settlement of the plate.
Settlement should be observed for each increment of load after an interval of 1,4,10, 20, 40
and 60 minutes and thereafter at hourly interval until the rate of settlement becomes less than
about 0.02mm per hour. After this, the next load increment is applied. The maximum load
that is to be applied corresponds to 3 times proposed allowable bearing pressure.
The water table has a marked influence on the bearing capacity of sand or gravelly soil. If the
water table is already above the level of the footing, it should be lowered by pumping and the
bearing plate seated after the water table has been lowered just below the footing level. Even

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

103

Plate Load Test

if the water table is locate above 1 m below the base level of the footing, the load test should
be made at the level of the water table itself.
When a load settlement curve (Fig 9.2) does not indicate any marked breaking point, failure
may alternatively be assumed corresponding to settlement equal to one fifth of the width of
the test plate. In order to determine the safe bearing capacity it would be normally sufficient
to use a factor of safety of 2 or 2.5 on ultimate bearing capacity.
Plate load data
0
4

Settlement (mm)

8
12
16
20
24
28
32

10

Load kg/cm square


Chart 9.1 Load vs. Settlement

9.7

ENGINEERING USES OF TEST RESULTS

1. The Plate Bearing (or Loading) Test, is normally used to measure the short term
settlement of road sub-grade or building footings under their proposed design load.
The value of settlement against load is then used to check that the soil meets design
load settlement criteria. The test therefore is of use to both contractors and to
specifying authorities.
2. In addition to values of settlement, other soil parameters can be measured, or
calculated from the plate bearing test. These include Modulus of Sub-Grade Reaction,
permanent deformation characteristics of the soil and in some instances shear strength
of the soil.
3. This method of testing is used for determining the modulus of reaction of soils by
means of the plate bearing test and for determining the corrections to be applied to the

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

104

Plate Load Test

field test values by means of laboratory tests. The modulus of soil reaction is required
in rigid pavement design and evaluation.
4. This test method is used to estimate the bearing capacity of a soil under field loading
conditions for a specific loading plate and depth of embedment but also for load tests
of soil and flexible pavement components for use in evaluation and design of airport
and highway pavements.

9.8

PRECAUTIONS

1. Sample should make with care.


2. Apparatus should be handled carefully.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

105

California Bearing Ratio Test

10
CALIFORNIA
BEARING RATIO
TEST

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

106

California Bearing Ratio Test

10.1

INTRODUCTION

The CBR test was developed by California Division of Highway in 1929 as mean of classify
the suitability of a soil for use as a sub grade or base course material in highway construction.
The laboratory test measures the shearing resistance of a soil under controlled moisture and
density conditions.

DEFINITIONS

10.1.1

CALIFORNIA BEARING RATIO


The CBR for a soil is the ratio (expressed as %) obtained by dividing the penetration stress
required to cause a 3-in2 area (hence, a 1.95-in. diameter) piston to penetrate 0.10 in. into the
soil by a standard penetration stress of 1,000 psi.
It may be expressed in the equation form as

penetratio n.stress( psi).required .to. penetrate (0.10.inches )


100
CBR
1000 psi

Note: The 1,000 psi in the denominator is the standard penetration stress for 0.10 in.
penetration.

SU B G R A D E
The natural soil upon which the pavement is laid. The sub grade is seldom strong enough to
carry a wheel load directly.

10.2

OBJECTIVES OF TEST

This method describes the sampling of the sub grade for California Bearing Ratio
(CBR)The resulting information is used for pavement design thickness.

10.3

SCOPE OF TEST

This test method is used to determine layer thicknesses and in-place California Bearing Ratio
(CBR) and to obtain samples of the pavement layer, base, sub-base, and sub-grade for
laboratory testing. The test method is applicable to both asphalt concrete (AC) and Portlandcement concrete (PCC) pavements.
The strength of the sub grade is the main factor in determining the thickness of the pavement
although its susceptibility to frost must also be considered. The value of the stiffness of the
sub grade is required if the stresses and strains in the pavement and the sub grade are to be
calculated.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

107

California Bearing Ratio Test

10.4

STANDARD REFERENCE

ASTM D1883-73

10.5

MATERIALS & EQUIPMENT

1. CBR test apparatus: Compaction mold (6-in. diameter and 7-in. height),collar, spacer
disk ( 5.937 diameter and 2.416-in. height),adjustable stem and perforated plate,
weights, penetration piston(3 in in area)
2. Loading (compression) machine: with load capacity of at least 10,000 lb and
penetration rate of 0.05 in./min
3. Expansion measuring apparatus
4. Two dial gages (with accuracy to 0.001 in.)
5. Standard compaction hammer
6. Mixing bowl
7. Scales
8. Soaking tank
9. Oven

Figure 10.1 CBR test apparatus

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

108

California Bearing Ratio Test

10.6

TEST PROCEDURE

1. Place the mould with base plate containing the sample, with the top face of the
sample exposed, centrally on the lower platen of the testing machine.
2. Place the appropriate annular surcharge discs on top of the sample.
3. Fir into place the cylindrical plunger and force-measuring devise assembly with the
face of the plunger resting on the surface of the sample.
4. Apply a seating force to the plunger, depending on the expected CBR value, as
follows.
5. for CBR value up to 5%, apply 10 N
6. for CBR value from 5% to 30%, apply 50 N
7. for CBR value above 30%, apply 250 N
8. Secure the penetration dial gauge in position. Record its initial zero reading, or reset it
to read zero.
9. Start the test so that the plunger penetrates the sample at a uniform rate of
10.2mm/min, and at the same instant start the timer.
10. Record readings of the force gauge at intervals of penetration of 0.25mm, to a total
penetration not exceeding 7.5mm
11. After completing the penetration test or tests, determine the moisture content of the
test sample
12. Test results are plotted in the form of a load-penetration diagram by drawing a curve
through the experimental points. Usually the curve will be convex upwards but
sometimes the initial part of the curve is concave upwards and, over this section, a
correction becomes necessary. The correction consists of drawing a tangent to the
curve at its steepest slope and producing it back to cut the penetration axis. This point
is regarded as the origin of the penetration scale for the corrected curve.
13. Penetrations of 2.5mm and 5mm are used for calculating the CBR value. From the
test curve, with corrected penetration scale if appropriate, read off the forces
corresponding to 2.5mm and 5mm penetration. Express these as a percentage of the
standard forces at these penetrations. Take the higher percentage as the CBR value.

10.7

ENGINEERING USES OF TEST RESULTS

This test method is used to evaluate the potential strength of sub grade, sub base, and base
coarse material including recycled materials for use in road and airfield pavements. The CBR
value obtained in this test forms an integral part of several flexible pavement design methods.
For applications where the effect of compaction water content on CBR is unknown or where
it is desired to account for its effect, the CBR is determined for a range of water content,
usually the range of water content permitted for field compaction by using agencys field
compaction specification.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

109

California Bearing Ratio Test

10.8
1.
2.
3.
4.

PRECAUTIONS
Scale must be precise.
Width of groove must be accurate.
Depth of groove must be accurate.
Handle of turning pace should be done with care.

10.9

CALCULATIONS

CBR value for 2.5mm (0.1in) penetration


(

CBR value for 5.0mm (0.2in) penetration

10.10

CORRECTIONS TO CURVE

The correction to the curve and reading given on the next page should be done.

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

110

California Bearing Ratio Test

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

111

California Bearing Ratio Test

10.11

SAMPLE PROBLEM

SOIL TESTING LABORATORY


CALIFORNIA BEARING RATIO TEST
Moisture Content Determination
Before
compaction

after
compaction

Top 1 in layer
after soaking

Average moisture
content after
soaking

can no.

1-A

1-B

1-C

1-D

weight of can, W1 (g)

45.23

47.28

43.44

46.59

weight of can + wet soil, W2 (g)

315.94

326.01

304.71

356.37

weight of can + dry soil, W3 (g)

273.69

283.37

261.53

305.82

mc (%)=(W2-W3)/(W3-W1)100

18.49

18.06

19.79

19.50

Average moisture content before soaking (%) =


Average moisture content after soaking (%) =

18.27
19.64

Density Determination
Before soaking

After soaking

weight of mold + compacted soil specimen (g)

9020.9

9036.81

Weight of mold (g)

4167.5

4167.5

Weight of compacted soil specimen (g)

4853.4

4869.31

Area of soil specimen (in2)

28.278

28.278

height of soil specimen (in.)

141.39

141.39

Wet density (lb/ft )

130.76

131.19

Moisture content (%)

18.27

19.64

110.56

109.64

Diameter of mold (in.)

Volume of soil specimen (in.3)


3

Dry density (lb/ft )

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

112

California Bearing Ratio Test

Swell Data

Surcharge weight (lb)


Time
Date
Elapsed time (hr)
Dial reading(in.)
Initial height of soil specimen (in.)
Swell (% of initial height)

Initial swell
measurement
10
10:16 AM
5/26/2006
0
0
5
0

Final swell
measurement
10
10:16 AM
5/30/2006
96
0.0135
5
0.27

soaked

unsoaked

Bearing Ratio Data


Check one
Weight of surcharge (lb)

10

Proving ring calibration (lb/in)


Penetration
(in)

Proving ring dial


reading (in.)

0
0.025
0.05
0.075
0.1
0.125
0.15
0.175
0.2
0.3
0.4
0.5

0
0.0004
0.0008
0.0013
0.0016
0.0019
0.002
0.0022
0.0023
0.0026
0.003
0.0032

74000

Piston load (lb)


3=2proving ring
calibration
0
29.6
59.2
96.2
118.4
140.6
148
162.8
170.2
192.4
222
236.8

Area of piston
(in.2)

penetration stress
(psi)

5=3/4

3
3
3
3
3
3
3
3
3
3
3
3

0
9.86
19.73
32.06
39.46
46.86
49.33
54.26
56.73
64.13
74
78.93

Result
CBR at 0.10-in. penetration (%) = [corrected penetration stress for 0.10 in penetration (from curve of
penetration stress versus penetration)]/1000100 =
3.95
CBR at 0.20-in. penetration (%) = [corrected penetration stress for 0.20 in penetration (from curve of
penetration stress versus penetration)]/1500100=
3.78

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

113

California Bearing Ratio Test

Penetration stress (psi)

Curve of Penetration Stress vs Penetration

90
80
70
60
50
40
30
20
10
0
0

0.1

0.2

0.3

0.4

0.5

0.6

Penetration (in.)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

114

California Bearing Ratio Test

SOIL TESTING LABORATORY


CALIFORNIA BEARING RATIO TEST
Moisture Content Determination
Before
compaction

after
compaction

Top 1 in layer
after soaking

Average moisture
content after soaking

can no.
weight of can, W1 (g)
weight of can + wet soil, W2 (g)
weight of can + dry soil, W3 (g)
mc (%)=(W2-W3)/(W3-W1)100
Average moisture content before soaking (%) =
Average moisture content after soaking (%) =

Density Determination
Before soaking

After soaking

weight of mold + compacted soil specimen (g)


Weight of mold (g)
Weight of compacted soil specimen (g)
Diameter of mold (in.)
Area of soil specimen (in2)
height of soil specimen (in.)
Volume of soil specimen (in.3)
Wet density (lb/ft3)
Moisture content (%)
Dry density (lb/ft3)

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

115

California Bearing Ratio Test

Swell Data
Initial swell
measurement

Final swell measurement

soaked

unsoaked

Surcharge weight (lb)


Time
Date
Elapsed time (hr)
Dial reading(in.)
Initial height of soil specimen (in.)
Swell (% of initial height)

Bearing Ratio Data


Check one
Weight of surcharge (lb)
Proving ring calibration (lb/in)

Penetration (in)

Proving ring dial


reading (in.)

Piston load (lb)

Area of piston
(in.2)

penetration
stress (psi)

3=2proving ring
calibration

5=3/4

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

116

California Bearing Ratio Test

Result
CBR at 0.10-in. penetration (%) = [corrected penetration stress for 0.10 in penetration (from curve of
penetration stress versus penetration)]/1000100 =
CBR at 0.20-in. penetration (%) = [corrected penetration stress for 0.20 in penetration (from curve of
penetration stress versus penetration)]/1500100=

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

117

Bibliography

BIBLIOGRAPHY

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

118

Bibliography

BIBLIOGRAPHY
Braja M. Das, Soil Mechanics Lab Manual,
Arpad Kezdi, Hand Book of Soil Mechanics and Soil Testing,
K. H. Head, Manual of Soil Laboratory Testing,
Joseph E. Bowles, Engineering Properties of Soil and Their Measurements, fourth edition,
BS 1377: Part 2 (1990), British Standard Methods of Test for Soil for Engineering Purposes.
Cheng Liu, Jack B. Evett, Soil Properties (Testing, Measurement and Evaluation), second
edition,
W. L. Schroeder, Soil in Construction (fifth edition),
ASTM 1988 Annual book of ASTM Standards
Book of Standards Volume: 04, Publisher: Taylor & Francis, Volume 22, Number 7 / 2004
Ashworth Manual, Embankment and Bas,
Prof. Krishna Reddy, UIC, Engineering Properties of Soils Based on Laboratory Testing
Soil mechanics work book
Dr. J. T. Germaine, Civil engineering material laboratory
Bardet, Jean-Pierre. (1997), Experimental Soil Mechanics. Prentice-Hall,
Means, R.E. and Parcher, J.V. (1963), Physical Properties of Soils
Ajay K. Duggal and Vijay P. Puri, Laboratory Manual in Highway Engineering,
H. S. Moondra, Rajiv Gupta, Lab Manual for Civil Engineering,
http://www.vulcanhammer.net Laboratory Soils Testing
http://www.mastrad.com/speed.htm
http://www.geneq.com/catalog/en/large_speedy.html
http://www.mbt.co.id/equipment/so-430.html

Balochistan University of of Information Technology Engineering & Management Sciences


(BUITEMS), Quetta

119

Bibliography

http://www.humboldtmfg.com/c-5-p-222-id-5.html
http://www.aimil.com/Search/ProductDetails.aspx?Id=913
http://www.udot.utah.gov/dl.php/tid
http://www.sddot.com/pe/materials/docs/matlsman/sd
http://www.civl.port.ac.uk/projects/geotech/geo4.html
http://geotech.uta.edu/lab/Main/atrbrg_lmts/index.htm
http://www.astm.org/cgi-bin/softcart.exe/database.cart/redline_pages/d4318.htm?e+mystore
http://www.civl.port.ac.uk/projects/geotech/geo5.html
http://www.stl-inc.com
http://www.atechcenter.com/hyd1.html
http://www.uwe.ac.uk/geocal