Above are not Process Design Condition hence shall not be included in Line
List.
Currently we are specifying above condition as Process Design Condition.
As per MD-101-SMEM-EG-PI-CRT-0001 section 4.9.3 the minimum Design
Pressure shall be as per Table 4-1
The Minimum Design Temperature shall be as per Table 4-2 of MD-101-SMEMEG-PI-CRT-0001
Refer IND-WI-L-209 Rev-1 section 4.2 for definition of Design Pressure &
Temperature.
Design Pressure = 1.1 X Max Operating Pressure as defined in Line List
Hydro-Test Pressure = 1.5 X Design Pressure (Line List)
Hydro-Test Pressure specified in PMCS is Maximum & shall not be exceed in
any case. This Test Pressure is based on Pipe Thickness & Class Rating
(Flange).