VERTICAL VAPOR LIQUID SEPARATOR SIZING

CheCalc.com

Chemical Engineering Calculations


User Input

INPUT
Vapor Flowrate
Vapor Density
Liquid Flowrate
Liquid Density
Liquid Holdup Time
Slug Capacity
L/D Maximum

10000.0 Kg/h
20.180 Kg/m
5000.0 Kg/h
736.10 Kg/m
5.0 min
0.57 m
3.0

INLET NOZZLE SIZING


Inlet Nozzle
Half
Momentum
User Input
Pipe ID Calculated
Select Pipe ID
Sch/ Thick
Pipe ID Selected

Tag No.
Description
Date
By

V-101
Receiver
10/4/2014
CheCalc

Operating Pressure
K Value Criterion
K Value Calculated
User Input K Value
Diameter Calculated
User Input Diameter

10.0
No Special Requireme
0.105
1100

VAPOR OUTLET NOZZLE SIZING


Momentum
4500
Pipe ID Calculated
108.3
Select Pipe ID
6.0
Sch/ Thick
40.0
Pipe ID Selected
154.1

Open Pipe
2100 Kg/m.s
Kg/m.s
145.6 mm
6.0 inch
40.0
154.1 mm

LIQUID OUTLET NOZZLE SIZING


Velocity
1.0
Pipe ID Calculated
49.0
Select Pipe ID
2.0
Sch/ Thick
40.0
Pipe ID Selected
52.5

SEPARATOR SIZING SUMMARY


Type
D
L

With Mist Eliminator


Separator Diameter
Separator Length

1100 mm
2900 mm

h1
h2
h3
h4
h5
h6
h7

Low liquid level to Bottom T/L


Level Range
High liquid level to Inlet nozzle
Diameter of Inlet nozzle
Inlet nozzle to Mist Eliminator
Thickness of Mist Eliminator
Mist Eliminator to Top T/L

150 mm
1202 mm
330 mm
168 mm
600 mm
150 mm
300 mm

L/D

2.64

With
Mist Eliminator
h7
h6
h5
h4
h3
h2
h1

Mesh

Partial Mesh Blanket

700 mm

Barg
l Requirement
m/s
m/s
mm
mm

Kg/m.s
mm
inch
mm

m/s
mm
inch
mm

Without
Mist Eliminator

h5
h4
h3
h2
h1

VERTICAL VAPOR LIQUID SEPARATOR SIZING


CheCalc.com

Chemical Engineering Calculations


User Input

INPUT
Vapor Flowrate
Vapor Density
Liquid Flowrate
Liquid Density
Liquid Holdup Time
Slug Capacity
L/D Maximum

22046.2 lb/h
1.260 lb/ft
11023.1 lb/h
45.95 lb/ft
5.0 min
149.52 Gallon (US)
3.0

INLET NOZZLE SIZING


Inlet Nozzle
Half Open Pipe
Momentum
1400 lb/ft.s
User Input
lb/ft.s
Pipe ID Calculated
5.74 inch
Select Pipe ID
6.0 inch
Sch/ Thick
40.0
Pipe ID Selected
6.065 inch

Tag No.
Description
Date
By

V-101
Receiver
10/4/2014
CheCalc

Operating Pressure
K Value Criterion
K Value Calculated
User Input K Value
Diameter Calculated
User Input Diameter

145.0
No Special Requireme
0.345
3.5

VAPOR OUTLET NOZZLE SIZING


Momentum
3000
Pipe ID Calculated
4.27
Select Pipe ID
6.0
Sch/ Thick
40.0
Pipe ID Selected
6.065

LIQUID OUTLET NOZZLE SIZING


Velocity
3.3
Pipe ID Calculated
1.9
Select Pipe ID
2.0
Sch/ Thick
40.0
Pipe ID Selected
2.067

SEPARATOR SIZING SUMMARY


Type
D
L

With Mist Eliminator


Separator Diameter
Separator Length

3.5 ft
10.0 ft

h1
h2
h3
h4
h5
h6
h7

Low liquid level to Bottom T/L


Level Range
High liquid level to Inlet nozzle
Diameter of Inlet nozzle
Inlet nozzle to Mist Eliminator
Thickness of Mist Eliminator
Mist Eliminator to Top T/L

6.0 inch
53.4 inch
12.0 inch
6.6 inch
24.0 inch
6.0 inch
12.0 inch

L/D

2.86

With
Mist Eliminator
h7
h6
h5
h4
h3
h2
h1

Mesh

Partial Mesh Blanket

2.5 ft

PSIG
l Requirement
ft/s
ft/s
ft
ft

lb/ft.s
inch
inch
inch

ft/s
inch
inch
inch

Without
Mist Eliminator

h5
h4
h3
h2
h1