Sunteți pe pagina 1din 102

TOTAL PROIECT SRL

ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

FIA CU RESPONSABILII LUCRRII

COLECTIVUL DE COORDONARE

DIRECTOR

: ing. KASSAY GBOR

_________________

EF PROIECT

: ing. KASSAY ERZSEBET

_________________

COLECTIVUL DE SPECIALITI

TEHNOLOGIE

: Dr. ing. Trk Ioan

CONSTRUCII EDILITARE

: ing. Trk rpd

INSTALAII

: ing. Kassay Erzsebet

ECOLOGIE

: ing. Szondi Erika

DESEN TEHNIC

: Balzs Mria

_________________
_________________
_________________
_________________
_________________

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

CUPRINS
1.

INTRODUCERE______________________________________________________________________________9

2.

IDENTIFICAREA AMPLASAMENTULUI SI LOCALIZARE___________________________________10

2.1

LOCALIZARE I TOPOGRAFIE_____________________________________________________________10

2.2

GEOLOGIE I HIDROLOGIE________________________________________________________________11

3.

ISTORICUL AMPLASAMENTULUI I DEZVOLTRI VIITOARE_____________________________13

3.1

ISTORICUL AMPLASAMENTULUI_________________________________________________________13

3.2

DEZVOLTRI VIITOARE____________________________________________________________________13

4.

ACTIVITI DESFURATE PE AMPLASAMENT________________________________________15

4.1

DESCRIEREA I FUNCIONAREA SI NSTALATIILOR______________________________________15

4.1.1
CAPTAREA
TRATAREA SI DISTRIBUTIA APEI STATIA DE TRATARE, RETEA
DISTRIBUTIE APA POTABIL_______________________________________________________________________15
4.1.1.1 ACTIVITATEA DESFURATA______________________________________________________________15
4.1.1.2 DESCRIEREA PROCESELOR TEHNOLOGICE, CAPTAREA TRATAREA APEI______________18
4.1.1.3 SISTEME DE CAPTARE___________________________________________________________________18
4.1.1.4 STAIA DE TRATARE APA POTABIL______________________________________________________20
4.1.1.5 DISTRIBUIA APEI POTABILE_____________________________________________________________22
4.1.1.6 DOTRI____________________________________________________________________________________23
4.1.1.7 BILANTUL DE MATERIALE________________________________________________________________26
4.1.1.8 UTILITATI__________________________________________________________________________________27
4.1.2

COLECTAREA SI TRATAREA APELOR UZATE CANALIZAREA MENAJERA ORASENEASCA


28

4.1.2.1 COLECTAREA APELOR UZATE - CANALIZAREA MENAJERA ORAENEASCA____________28


4.1.2.2 TRATAREA APELOR UZATE - STATIA DE EPURARE ORASENEASCA____________________36
4.1.2.3 DESCRIEREA PROCESELOR TEHNOLOGICE______________________________________________36
4.1.2.4 DOTARI____________________________________________________________________________________40
4.1.2.5 BILANUL DE MATERIALE________________________________________________________________42
4.1.2.6 MATERII PRIME SI MATERIALE

FOLOSITE______________________________________________42

4.1.2.7 UTILITATI__________________________________________________________________________________43
4.2

MATERIALE DE CONSTRUCII____________________________________________________________43

4.3
STOCAREA DE MATERIALELOR DEPOZITE DE MATERII PRIME, REZERVOARE
SUBTERANE_________________________________________________________________________________________43
4.3.1

REZERVOARE SUBTERANE AFLATE N ZON____________________________________________43

4.4
EMISII IN ATMOSFER,
EMISII DE PROCESE TEHNOLOGICE, ALTE EMISII IN
ATMOSFER________________________________________________________________________________________44
4.4.1

LA OBIECTUL ALIMENTARE CU APA______________________________________________________44

4.4.2

LA OBIECTUL CANALIZARE SI STATIE DE EPURARE_____________________________________46

4.5
ALIMENTARE CU AP EFLUENTI TEHNOLOGICI I MENAJERI, SISTEMUL DE
CANALIZARE A APELOR UZATE____________________________________________________________________49
4.5.1

PROTECTIA CALITATII APELOR___________________________________________________________49

4.5.1.1 CAPTAREA SI TRATAREA APELOR UZATE________________________________________________49


4.5.1.2 CANALIZAREA SI STAIA DE EPURARE___________________________________________________50
4.6

PRODUCEREA SI ELIMINAREA DEEURILOR_____________________________________________52

4.6.1

CAPTAREA, TRATAREA ALIMENTARE CU APA____________________________________________52

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

4.6.2

CANALIZARE, STATIE DE EPURARE______________________________________________________53

4.7

ALIMENTARE CU ENERGIE ELECTRICA SI ASIGURAREA ENERGIEI TERMICE___________54

4.8

PROTECIA MUNCII SI IGIENA LOCULUI DE MUNC____________________________________54

4.9

PREVENIREA SI STINGEREA INCENDIILOR_______________________________________________55

4.10

ZGOMOTUL I VIBRAIILE________________________________________________________________55

4.11

SECURITATEA ZONEI______________________________________________________________________56

4.12

PROXIMITATEA CABLURILOR ELECTRICE________________________________________________56

4.13

SURSE DE INFORMARE___________________________________________________________________56

5.

CALITATEA SOLULUI______________________________________________________________________56

5.1

EFECTE POTENIALE ALE ACTIVITII DE PE AMPLASAMENTUL ANALIZAT___________56

5.2

EFECTE POTENIALE ALE ACTIVITILOR NVECINATE_________________________________57

6.

DESCRIEREA SI REZULTATELE INVESTIGATIILOR________________________________________61

6.1

INVENTARIEREA SI EVALUAREA SURSELOR DE EMISII__________________________________61

6.1.1

POLUAREA APELOR DE SUPRAFATA SI SUBTERANE_____________________________________61

6.1.2

DESCRIEREA SI REZULTATELE INVESTIGAIILOR_______________________________________63

6.2

POLUAREA SOLULUI_______________________________________________________________________68

6.2.1

SURSE DE POLARE A SOLULUI___________________________________________________________68

6.2.2

REZULTATELE DETERMINARII REALIZATE________________________________________________69

6.3

POLUAREA AERULUI______________________________________________________________________72

7.

CONCLUZII SI RECOMANDARI____________________________________________________________73

8.

PROPUNERI PENTRU PROGRAME DE CONFORMARE___________________________________74

8.1

PROPUNERI PT MODERNIZAREA STATIEI DE EPURARE_________________________________74

8.2

PROPUNERI PT GOSPODARIREA DESEURILOR__________________________________________78

8.3

PROPUNERI PT MONITORIZAREA TEHNOLOGICA_______________________________________78

9.

SCURT REFERAT NETEHNIC______________________________________________________________78

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

B. ANEXE LA PIESE SCRISE

Certificat de nregistrare nr 24499588 SC Harviz SA

Certificat constatator pt unitatea SC Harviz Sa

Contractul de delegare a serviciului public de alimentare cu apa si canalizare


ncheiat cu Oraul Vlhia nr 34/01.09.2009

Autorizaie de gospodrire a apelor 274/31.01.20012


potabila si evacuarea apelor uzate pentru oraul Vlhia

Hotrrea nr 37/2010 privind delegarea gestiunii serviciului de alimentare cu


apa si canalizare vatre SC Harviz Sa

Proces Verbal de predare preluare s bunurilor necesare realizrii serviciilor


delegate

Protocol de predare primire

Ordin nr 547/03.10.2011 pentru modificarea Ordinului preedintelui Autoritarii


Naionale de Reglementare pt Serviciile Comunitare de Unitati Publice nr
305/22.06.2010

Licena nr 1005/2010pentru serviciul public de alimentare cu apa si canalizare

Monitorizarea funcionarii staiei de epurare din Vlhia anul 2011

ndrumar nr 6155/2011 emis de APM Harghita

Breviare de calcule nr. 1, 2a, 2b

pt alimentare cu apa

Propunere de program de conformare corespunztor obligaiilor de mediu.


Raport de incercare nr 122153/12.11.2012 realizat de Laboratorul Wessling
Romania SRL

C. PIESE DESENATE
Plan de ncadrare n zon

1:100 000 Plana nr. 01.

Plan de ncadrare n zon 2 1:100 000 Plana nr. 02.


Plan incinta tratarea apei 1: 25 000 Plana nr. 03.
Plan retea de distributie a apei

: 1000

Plan canalizare
Plan Statie de epurare
Plan modernizare statie de epurare

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

ELEMENTE DE COORDONARE
Bilanul de mediu s-a ntocmit n conformitate cu reglementrile specifice din domeniul
proteciei mediului, respectiv:
Ordonana de Urgen a Guvernului nr. 195/2005 privind Protecia Mediului, aprobat cu
modificri i completri prin Legea nr. 265 din 2006, cu modificrile i completrile
ulterioare.
Ordin MAPPM nr 184 /1997 pentru aprobarea procedurii de realizare a bilanurilor de mediu
Legea apelor nr. 107/1996, modificat i completat prin Legea 310 din 2004.si Legea 112
din 2006.
Ordinul M.S. nr. 536/1997 pentru aprobarea normelor de igien i a recomandrilor privind
mediul de via al populaiei.
Hotrrea Guvernului nr.445/2009 privind evaluarea impactului anumitor proiecte publice si
private asupra mediului.
O.M. nr. 135/76/84/1284 din 10 februarie 2010 privind aprobarea a Metodologiei de aplicare
a evalurii impactului asupra mediului pentru proiecte publice i private.
Ordin MAPM nr. 863/2002, privind aprobarea ghidurilor metodologice aplicabile etapelor
procedurii cadru de evaluare a impactului asupra mediului.
Ordonana de Urgenta a Guvernului nr. 57/2007 privind regimul ariilor naturale protejate ,
conservarea habitatelor naturale, a florei si faunei slbatice cu modificrile si completrile
ulterioare .
HG 1284/2007 privind declararea ariilor de protectie avifaunistica CA PARTE INTEGRANTA A
RETELEI ECOLOGICE Natura 2000 in Romania.
Ordinul Ministrului Mediului si Dezvoltrii Durabile nr. 1964/2007 privind instituirea
regimului de arie naturala protejata a siturilor de importanta comunitar ca parte integranta
a reelei ecologice europene Natura 2000 modificat prin Ordinul Ministrul si Pdurilor nr.
2387/29.09.2011.
Hotrre pentru modificarea si completarea Hotrrii Guvernului nr 1284/2007 privind
declararea ariilor de protectie speciala avifaunistica ca parte integranta a reelei ecologice
europene Natura 2000 in Romania
HG nr. 930/2005 pentru aprobarea normelor speciale privind caracterul i mrimea zonelor
de protecie sanitar i hidrogeologice modificat si completat prin Ordin 1278/2011 .
Hotrrea Guvernului Romniei nr. 525/1996 pentru aprobarea Regulamentului general de
urbanism.
Ordinul nr. 1430/2005 al Ministrului lucrrilor publice, transporturilor i locuinei pentru
aprobarea Normelor metodologice de aplicare a Legii nr. 50/1991 privind autorizarea
executrii lucrrilor de construcii, republicata cu modificrile i completrile ulterioare.
HGR nr.188/2002, pentru aprobarea unor norme privind condiiile de descrcare n mediul
acvatic , modificata si completat prin HG 352/2005 ( cu anexele NTPA 001 , NTPA 002 ,
NTPA 0011 ).
6

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

HG 351/2005 privind programul de eliminare treptata a evacuri emisiilor si pierderilor de


substante prioritar periculoase , modificata si completata prin HG &*#/2006.
Legea 104 /2011 privind calitatea aerului nconjurtor.
Legea nr. 426/2001 pentru aprobarea Ordonanei de urgen a Guvernului nr. 78/2000
privind regimul deeurilor.
HGR nr. 349 /2005 privind depozitarea deeurilor.
Ordinul nr. 757/26.11.2004. Normativ tehnic privind depozitarea deeurilor.
HG nr. 621/2005 privind gestionarea ambalajelor i deeurilor de ambalaje, cu modificrile
i completrile ulterioare.
HGR nr. 856 din 16 august 2002 privind evidena gestiunii deeurilor i pentru aprobarea
listei cuprinznd deeurile, inclusiv deeurile periculoase.
HGR nr. 1132/2008 privind regimul bateriilor i acumulatorilor care conin substane
periculoase.
Ordinul Ministrului Mediului i Gospodririi Apelor nr. 95/2005 privind stabilirea criteriilor de
acceptare i procedurilor preliminare de acceptare a deeurilor la depozitarea i lista
naional de deeuri acceptate n fiecare clas de depozit de deeuri.
HGR nr. 235/2007 privind gestionarea uleiurilor uzate.
HGR nr. 621/2005 privind gestionarea ambalajelor i a deeurilor de ambalaje, cu
modificrile i completrile ulterioare.
Lege nr. 101/2006, legea serviciului de salubrizare a localitilor, cu modificrile i
completrile ulterioare.
HG nr. 1061/2008 privind transportul deseurilor periculoase si nepericuloase pe teritoriul
Romniei.
HGR nr. 1037/2010 privind deeurile de echipamente electrice i electronice.
Ordinul comun M.M.G.A. nr. 344/2004 si M.A.P.D.R. nr 708/2004 pentru aprobarea Normelor
tehnice privind protectia mediului si inspecial a solurilor cand se utilizeaza namolurile de
epurare in agricultura.
HG nr. 1061/2008 privind transportul deseurilor periculoase si nepericuloase pe teritoriul
Romniei.
STAS 10009/1998 Acustica urbana limite admisibile ale nivelului de zgomot. STAS
6156/1986 Protecia mpotriva zgomotului n construcii civile i social culturale limite
admisibile i parametrii de izolare acustic.
Ordinele Ministrului Transporturilor nr.537/1997 i nr. 251/1999 cu privire la aprobarea
condiiilor pe care trebuie s le ndeplineasc autovehiculele pentru a fi admise n circulaia
pe drumurile din Romnia.

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

RAPORT
LA BILANUL DE MEDIU NIVEL I

DATE GENERALE
DENUMIREA OBIECTIVULUI
BILAN DE MEDIU NIVEL I I NIVEL II AFERENT STAIEI DE EPURARE I REELEI DE
CANALIZARE MENAJER N ORAULUI VLAHIA JUDEUL HARGHITA
AMPLASAMENTUL
ORASUL VLHIA SI SATUL MINELE LUETA
VIII.1.67

JUDEUL HARGHITA COD CADASTRAL

CAPTAREA VRGHIS ZMEURI INSTALATIA DE TRATARE SI REEA DE DISTRIBUIE


APA POTABILA VLHIA INTRAVILAN. COLECTAREA SI TRATAREA APELOR UZATE
MENAJERE, STATIA DE EPURARE VLHIA
PROPRIETAR
8

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

CONSILIUL LOCAL AL ORASULUI VLHIA STR TURNATORILOR Nr 20 JUDEUL


HARGHITA
TEL /FAX 0266-246635, 0266-246634
OPERATOR: S.C. HARVIZ S.A. MIERCUREA CIUC STR SALCM NR 1 JUD. HARGHITA
TEL 0266-313636, CUI RO 24499588 NR INREG J19/917/2008
PROFILUL DE ACTIVITATE
CAPTAREA, TRATAREA I DISTRIBUIA APEI
COLECTAREA I TRATAREA APELOR UZATE

COD CAEN 4100


COD CAEN 9100

REGIM DE LUCRU
365 zile/an, 24 ore/zi
ELABORATOR BILAN
S.C. TOTAL PROIECT SRL ODORHEIU SECUIESC STR KOSSUTH LAJOS NR 13
JUDEUL HARGHITA COD 535600, TEL/FAX 0266-218.447 E-mail, office
@totalproiect. ro
PROIECT NR

2710 /2012

CAP. A

BILAN DE MEDIU NIVEL

1. INTRODUCERE
Prezenta lucrare s-a ntocmit la solicitarea Societii Comerciale HARVIZ SA
MIERCUREA CIUC Str. Salcm nr 1 Judeul Harghita Operator pentru serviciul public de
alimentare cu apa si de canalizare al orasului Vlhia in baza Ordinului preedintelui ANRSC
nr 574/03.10.2011, cat si in baza contractului de Delegare a Gestiunii nr 34/01.09.2009
ncheiat cu Asociaia de Dezvoltare Intercomunitara HARGHITA VIZ in oraul Vlhia.
Societatea Comerciala SC Harviz SA cu sediul social Municipiul Miercurea Ciuc Str. Salcm
nr 1 Judeul Harghita Cod Unic de nregistrare 24499588 /23.09.2008 Nr ordine in registrul
comerului J19/917/22.09.2008 avnd activitatea principala Captarea tratarea si distribuia
apei cod CAEN 4100. Bilanul de mediu este necesar n procesul de autorizare in
vederea stabilirii elementelor programului de conformare . Prin bilanul de mediu se va
evalua impactul asupra mediului prin studii teoretice investigaii realizate la fata locului ,
msurtori de noxe emise in apa aer si sol , efectuate asupra obiectivului CAPTAREA ;
TRATAREA SI DISTRIBUIA APEI RESPECTIV COLECTAREA SI TRATAREA APELOR
9

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

UZATE IN ORASUL VLHIA si care este situat n intravilanul si extravilanul orasului


Vlhia Judeul Harghita.
Scopul studiului este de a analiza efectul activitilor din unitatea studiat asupra factorilor
de mediu i de a identifica ariile cheie de importan din punct de vedere al mediului
nconjurtor determinate pentru desfurarea activitii viitoare pe amplasamentul studiat.
Aceast analiz are loc n procesul de autorizare a unitatii susmenionate, solicitata de
Agenia pentru protectia Mediului Harghita cu ndrumarul nr. 6155/20 iunie 2011 in
vederea determinrii strii de poluarea factorilor de mediu, starea i eficiena funcionrii
sistemelor de depoluare existente sau cele necesare, restriciile existente n zon, pt. a se
ncadra n normele prescrise privind calitatea aerului, apei, solului i subsolului i cele
referitoare la zona studiat a localitii Vlhia, unde se afl obiectivul.
Bilanul de mediu nivel I i II trebuie sa identifice domeniile n care impactul asupra
mediului produs de funcionarea obiectivului analizat poate fi semnificativ. Lucrrile se vor
concentra asupra modului de conformare cu prevederile legislaiei existente precum i
asupra investigrii potenialelor poluri ale solului prin activiti desfurate anterior n
zona analizata sau nvecinata acesteia. Bilanul de mediu nivel I trebuie s conduc la
concluzia n ce msur este necesar continuarea investigaiilor prin bilan de mediu de
nivel II sau rezultatele sunt concludente din aceast etap.
Bilanul de mediu nivel II reprezint o etap superioar de analiz a activitii pe
amplasament n raport cu cerinele de mediu; acesta trebuie s adnceasc i s clarifice
natura i intensitatea polurii, n acest scop sunt necesare n mod expres prelevri de probe
i analize corespunztoare. Metodele de prelevare a probelor din diferite medii vor respecta
reglementrile, normele metodologice i standardele existente. n conformitate cu
prevederile Ordinului M.A.P.P.M. nr. 184/1997, se va preleva probe pentru analiza: sol la
adncime de 5 cm si 30 cm cat si foraje mai adnci in vederea depistrii prezentei
poluanilor penetrai in sol, ape subterane din foraje executate, ape uzate evacuate,
materiale de construcii, deeuri tehnologice, emisii i imisii de noxe, compoziia pulberilor
sedimentabile rezultate din instalaia industriala.
n vederea ntocmirii acestei analize au fost consultate studiile de specialitate,
documentaiile i documentele referitoare la zona n care se afl obiectivul, datele existente
cu privire la factorii de mediu. Au fost prelevate i executate analize de laborator pentru
determinarea nivelului polurii solului, apelor freatice din zon., ct i controlul respectrii
parametrilor de evacuare a apelor uzate precum i msurtori de imisii de noxe.
Locul de prelevare a probelor din sol i ape uzate este prezentat n planul general.
2.

IDENTIFICAREA AMPLASAMENTULUI SI LOCALIZARE

2.1 LOCALIZARE I TOPOGRAFIE

Oraul Vlhia este situat la S-E de masivul Harghita, pe cursul superior al rului
Homorodul Mic, pe platoul Harghita. Accesul n zon se realizeaz prin drumul naional DN
13A Miercurea-Ciuc Odorheiu-Secuiesc, Oraul Vlhia se afl la o distan de 26 km de
reedina de jude, Miercurea Ciuc.
Localitatea este amplasat pe valea prului Vrghi i Homorodul Mic, avnd codurile
cadastrale VIII-1.67 respectiv VIII.1-71.6.
Oraul Vlhia este situat pe DN 13 a ( Miercurea Ciuc, Odorheiu Secuiesc, la cota 850 m
DM, la interfluviul dintre prurile Vrghi si Homorodu Mic
Sistemul de tratare a apei potabile se afla in partea estica a localitii Vlhia in extravilanul
localitii langa prul Vrghi, Zmeuri.
Vedere UZINA DE APA

10

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Staia de epurare se afla in aval de localitate langa parau Homorodul Mic si Halda de steril a
fostei turnatorii Vlhia.

Amplasamentul staiei de epurare fiind situat n zon industrial nu prezint o sensibilitate


deosebit fa de peisaj, fiind situat la o distan considerabil de cartiere populate sau
altor folosine sensibile a terenului ca spitale, coli, locuri de cult, amenajri publice sau
obiective de agrement turistic.
Zona dispune de dotri hidroedilitare: alimentare cu ap potabil, reele de gaze naturale,
reele electrice de nalt i de joas tensiune, staii de transformatoare, drumuri de acces;
nu dispune de reea de canalizare menajera si pluviala.
2.2

GEOLOGIE I HIDROLOGIE

Localitatea Vlhia se situeaz pe platforma din partea vestic a Harghitei.


Elementul structural dominant este reprezentat de lanul eruptiv neogen Harghita, care
traverseaz regiunea de la NV la SE, vrfurile de maxim altitudine marcheaz de fapt
crestele vechilor aparate vulcanice, cum sunt : Harghita Mdraului ( 1801 m ),umuleul
Mare( 1577 m ). Fa de lanul eruptiv, nlimile scad treptat spre vest.Oraul VLAHITA din
Judeul Harghita, unde se afl amplasamentul studiat, este situat n partea centralsudica
a judeului, , geografic fiind aezat pe platoul vulcanic de vest al masivului Harghita. Este o
11

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

zona de platou , cu uoara nclinare spre sud sud-est, brzdata de vai adnci erodate ale
cursurilor de apa, direcionate, nord-sud.
Altitudinea medie a localitii este aproximativ 850 m, de la nivelul marii, cea minima si
maxima 670 m (extremitatea sudica Minele Lueta) respectiv 925 m (extremitatea nordica).
Sub aspect geomorfologic este deci caracteristica formaiunea de platou in care se
adncesc vile cursurilor de apa, cu versant abrupi , perspectiva deprtata fiind dominata
de crestele Harghitei.
Din punct de vedere structural tectonic regiunea face parte din platforma din partea
vestic a lanului vulcanic Harghita, i este caracterizat prin depozite pliocene i cuaternar,
constituite n special din piroclastice n alternan cu depozite aluvionare psefitice,
psamitice i cinerit.
Depozitele aluvionare n valea Homoroadelor care traverseaz satul n special al
Homorodului Mic - sunt alctuite dintr-un amestec nesortat de pietriuri i nisipuri, n care
predomin elementele constituite din andezite, isturi cristaline, calcare, cu un grad de
rulare puin avansat. Depozitele aluvionare se ntlnesc i sub forma unor conuri de dejecie
la gura afluenilor mai mari, fiind reprezentate prin bolovniuri i pietriuri colmatare cu
argil, argil nisipoas i cinerit.
Oraul este traversat de prul Homorodul Mic, principala arter a zonei, n care este
deviat i o parte din apele Vrghiului, care curge paralel cu Homorodul Mic la est de ora.
Izvoarele care apar pe valea prului au un debit variabil, multe din ele sunt diferite tipuri
de ap mineral carbogazoas.
Suprafeele relativ restrnse, acoperite cu pdure, favorizeaz scurgerea rapid a apelor
pluviale, care n genere nu au timp suficient s se acumuleze n subteran,
Aezarea sa dezvoltat in direcia nord-est sud-vest, pe interfluviul intre Homorodul Mic si
Vrghi, fiind strbtuta de acesta in extremiti. De-lungul localitii cu sute de ani in
urma a fost creat artificial Canalul Vrghi, care fcea legtura dintre cele doua cursuri de
apa amintite, constituind astzi cursul de apa principala ce traverseaz localitatea
Oraul Vlhia se situeaz la distanta egala fata de cele doua centre urbane importante a
judeului, Miercurea Ciuc (28 km) si Odorheiu Secuiesc, (24 km), pe Drumul Naional DN 13
A, artera de comunicaie de mare nsemntate intre aezrile din podiul Transilvaniei si
depresiunile intramontane (a Ciucului) si mai departe ctre teritoriile dincolo de Carpai. O
caracteristica particulara a localitii este faptul ca aceasta artera principala, Drumul DN 13
A, o strbate pe o distanta scurta, aezarea fiind dezvoltata in direcie perpendiculara. Din
centrul localitii bifurca drumul Judeean DJ 132, care constituie strada principala oraului.
asigurnd legtura cu bazinul Baraoltului, prin Lueta, Mereti.
Oraul Vlhia se nvecineaz cu localitile : localitile comunei Siculeni, Miercurea Ciuc,
Lueta, Comuna Mrtini, comuna Brdeti, Cplnia, Zetea. Legtura se realizeaz
exclusiv prin cai rutiere.
Istoric si geografic oraul Vlhia este constituit din localitile: Vlhia Sat, Baia Sfnta
Cruce, si Minele Lueta , primele doua fiind contopite, a treia formnd un trup separat, aval
de oraul propriu zis. Aezarea geografica si condiiile naturale au fost determinate si in
privina evoluiei istorice. Clima aspra nefavorabila agriculturii , un bogat fond forestier,
prezenta minereului de fier, dar si aezarea strategica au fost de natura sa imprime
localitii caracterul sau specific pstrat si astzi.
GEOMORFOLOGIA
Oraul Vlhia este aezat n partea S-V a judeului Harghita, la periferia Podiului
Transilvaniei, la poalele Munilor Harghita, pe un platou care prezint un relief plan,
strbtut de vile praielor ce se izvorsc din caldeirele aparatelor vulcanice.
GEOLOGIA I SEIZMICITATEA
12

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Structurarea geologic a zonei este strns legat de subsidena bazinului intracarpatic, care
a nceput n Badenian, sedimentarea extinzndu-se spre E pn i peste rama intern a
zonei cristalino-mezozoice, i de edificarea aparatelor vulcanice ale lanului vulcanic
Climani-Harghita. Badenianul apare la suprafa numai la aval de oraul Vlhia, de-a
lungul vii rului Homorodul Mic i este reprezentat prin tufuri dacitice peste care se
situeaz orizontul argilo-marnos cenuie cu intercalaii de gresii i lentile de sare.
Badenianul superior este reprezentat prin pachete de nisip cu intercalaii de argile
marnoase cenuii, gresii i tufuri dacitice.
Sarmaianul afloreaz pe suprafee extinse, la S-E de valea Homorodului Mic Este alctuit
dintr-o alternan de conglomerate cu matrice nisipoas i gresii argiloase.
Cuaternarul este reprezentat de aluviunile recente sau deluviile teraselor joase din lungul
vii Homorodului Mic.
Formaiunile de origine magmatic formeaz masa platoului Harghitei, sunt reprezentate de
un compartiment inferior vulcanogen-sedimentar i un compartiment superior
stratovulcanic.
Compartimentul inferior vulcanogen-sedimentar, format n prima etap, cnd activitatea
exploziv a fost mai intens, este reprezentat prin depozite piroclastice vulcanice cu
grosimi mari i extindere important. Pe versantul vestic i sud-vestic al catenei vulcanice
aceste depozite ating lrgimea de 40 km i grosimea de cca. 600 m, prezentnd tendine de
ngroare spre N i E. Forma acestei uniti structurale poate fi asimilat cu aceea a unei
plci aezate peste fundamentul prevulcanic. Este rezultatul att factorilor endogeni ct i
celor exogeni.
Compartimentul stratovulcanic este constituit din vulcanoclastite andezitice grosiere,
haotice, nestratificate, alctuite din blocuri subangulare cu liant cineritic sau nisipos.
Depozitele de cdere sunt prezente subordonat. Fenomenele de transformare postvulcanice
sunt frecvente: limonitizri, sideritizare, bentonitizri i caolinitizri. n cadrul acestui
compartiment au fost separate 3 secvene la nivel regional, pe ntreg teritoriul vulcanic. La
alctuirea acestor secvene particip roci terigene i vulcanogene variate privind
granulometria, faciesul i tipul petrografic. Complexul vulcanogen-sedimentar cuprinde i
zcminte hidrotermale de Fe i metale feroase accesorii, exploatate pn n sfritul
secolului trecut la mina Vlhia.
Condiiile de fundare sunt redate n Memoriile tehnice pe specialiti Rezisten.
Conform Normativ cu indicativ P 100-92, amplasamentul se ncadreaz n zona seismic de
calcul E, intensitate seismic 7 grade M.S.F., conform SR 11100/1, caracterizat prin
coeficientul seismic Ks = 0,12 i perioada de col Tc = 0,7 sec.
HIDROGRAFIA I HIDROGEOLOGIA ZONEI
Reeaua hidrografic este constituit din rurile Homorodul Mic i Vrghi, precum i din
afluenii lor. Homorodul Mic traverseaz oraul pe direcia aproximativ NE-SV. Sistemul
hidrografic are un potenial mediu de eroziune, datorit energiei sczute al reliefului, iar la
S de oraul Vlhia vile rurilor devin adnci cu un potenial mare de eroziune.
CLIMA
Clima este caracteristic regiunilor montane cu temperaturi sczute / media anuala
nedepind 6 o C, precipitaii abundente / peste 1000 mm/an, mai mari in lunile de
primvara, vara, si vnturi puternice din direcia nord - est, si sud-vest . Temperatura medie
anual este cuprins ntre 5-6C. Temperaturile medii lunare cele mai reci , ianuarie ,
coboar la -6 C Minimele zilnice scad frecvent n lunile de iarn sub -30C, iar maximele
ating uneori vara 35 C. Numrul medii a zilelor cu nghe ajunge n medie la 125 zile pe
an. Sunt frecvente n perioada de iarn inversiunile termice. Durata stratului de zpad este
cuprins ntre 114 - 140 zile pe an. Umezeala relativ a aerului este ridicat avnd valori

13

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

medii de 88% n ianuarie, 72% n aprilie-iunie i 80% n oct octombrie. Nebulozitatea este
variabil. Numrul de zile senine este de 80 zile pe an, iar al zilelor acoperite 150 pe an.
Starea aerului este caracterizat prin calm, cu o frecven de 55,7%. Direciile
predominant ale vntului sunt cele de vest i nord - vest. Viteza medie a vntului este de
2.9-3,5 m/s.
Caracterul geo-climatic al zonei , regimul eolian in mod preponderent a determinat si modul
de construire si de ocupare a terenului , cu densitate mare a construciilor, aezate dea
lungul vilor adnci , relativ ferit de vnturile de pe platoul ntins. Aezarea sa format
aproape liniar pe o lungime considerabila, pe o lime de maxim 500 m.
3.

ISTORICUL
VIITOARE

3.1 ISTORICUL

AMPLASAMENTULUI

DEZVOLTRI

AMPLASAMENTULUI

Prima atestare documentara a localitii se dateaz di anul 1406 ce a ce nseamn ca


aezarea este mai veche , Activitatea de baza a locuitorilor a fost exploatarea si prelucrarea
lemnului, completata de creterea animalelor , pdurile si punile fiind cuprinse in
composesorat, apoi metalurgia , mineritul si prelucrarea minereului de fier au marcat o
trstura fundamentala a activitilor economice.
In zona au funcionat zecii de gatere multe din ele in proprietate interfamiliala , devierea
prului contribuind si la ntemeierea metalurgiei. Prima atestare documentara a unei forje
pe aceste meleaguri se face in anul 1591 , pe teritoriul comunei Lueta. Dezvoltarea
metalurgiei se leag de timpurile vechi de aceasta comuna prima ntreprindere de profil
fabrica de fier fiind ntemeiata in anul 1836. Cea mai spectaculoasa dezvoltare se petrece
ncepnd din anii
70-80. aceasta dezvoltare forata atrage dup sine o decdere
accentuata in anii 90. Epuizarea minelor care au fost nchise in anul 1984. lipsa unui
mijloc de transport economic , au fcut nerentabil activitatea metalurgica multiseculara in
condiiile echiprii actuale
Este important de menionat problemele legate de protecia i conservarea mediului. n
acest sens oraul Vlhia poate fi calificat (dup planul urbanistic al localitii) ca
prezentnd,probleme semnificative. Existena industriei metalurgice este principal surs
de poluare i disconfort. Dei producia a sczut mult, se mai constat efecte poluante, iar
depozitele de steril sunt creatoare de probleme, inclusiv colmatarea albiei prului i
favorizeaz
inundaiile n acest mod. Exist i alte aspecte deranjante ca: poluarea produs de
depozitarea deeurilor n locuri neamenajate, nchiderea depozitului de deeuri menajere
corespunztoare fiind o problema n centrul ateniei. Situat ntr-un cadru natural favorabil,
fac ca situaia n acest domeniu s fie menajabil, problema principal fiind cea a
conservrii strii mediului nconjurtor.
3.2

DEZVOLTRI VIITOARE

Este in curs derularea investiiei:


DENUMIREA INVESTIIEI
REALIZAREA CANALIZRII MENAJERE N ZONA NAGYFALU I EXTINDEREA STAIEI DE
EPURARE ZONA DL
PROIECTANT
TOTAL PROIECT SRL ODORHEIU SECUIESC
14

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Str. Kossuth Lajos nr.13; Cod potal: 535600; Tel: 0266 218 447; Fax: 0266 217 967;
AUTORITATEA CONTRACTANT
ORA VLHIA JUDEUL HARGHITA
Vlhia Str. Turntorilor nr. 20, jud. Harghita, Tel/Fax: 0266-246635/0266-246634
INVESTIA CONST IN:
REALIZAREA - REEAUA DE CANALIZARE
Conform studiului de fezabilitate avizat i aprobat, se prevede executarea unei reele de
canalizare n sistem separativ, care colecteaz i transport apele uzate menajere n staia
de epurare aval de localitatea.
Apele uzate ce urmeaz a fi canalizate dup provenien sunt: ape uzate menajere,
rezultate din satisfacerea nevoilor de ap gospodreti i igienico-sanitare ale locuitorilor;
ape uzate publice, rezultate din satisfacerea nevoilor de ap din instituiile i unitile
publice;
Amplasarea canalelor i a obiectelor care alctuiesc canalizarea s-a fcut dup o schem
ramificat.
Structura reelei de canalizare este arborescent: canalele de racord converg n canale
colectoare secundare ce se reunesc n colectoare principale, ce se termin la staia de
epurare, aceste canale s-au proiectat n funcie de:
sistematizarea zonei;
cantitatea i calitatea apei de canalizare;
relieful terenului;
puncte obligate i obstacole i
extinderea reelei n perspectiv.
Apele uzate din buctrii, cantine sau restaurante, care impun n mod special separarea
grsimilor nainte de epurare, vor fi n prealabil trecute printr-un separator de grsimi. Apele
uzate provenite de la unitile medicale, precum i de la alte instituii, care prin specificul
lor contamineaz apele uzate cu ageni patogeni, vor fi evacuate la canalizarea exterioar
cu luarea msurilor de dezinfecie. Instalaia interioar de canalizare se va lega, la reeaua
exterioar, prin intermediul unui cmin de racord, amplasat la limita incintei.
Racordarea cminelor de incint la reea se va face la racord de creast, evitnd formarea
de remuuri n sectoarele amonte, canalele avnd o capacitate se scurgere mai mare dect
cea de calcul. ncrcarea apelor uzate evacuate n reeaua de canalizare se vor ncadra n
valorile maxime prescrise prin NTPA 002/2005.
La proiectare sistemului de canalizare s-a prevzut s se asigure o perfect etaneitate, o
net separare de reeaua de alimentare cu ap (cu care nu trebuie s vin n contact i n
nici un caz s nu treac deasupra ei) ca s se evite orice posibil contaminare. S-a prevzut
o cdere suficient, adncime corespunztoare ca s nu apar iarna nghe i
dimensionrile (diametre) adecvate ca s permit preluarea ntregului debit, s nu se
ajung la blocaje i refulri la exterior pe strzi sau i mai ru n interiorul cldirilor.
La proiectarea traseului reelei de canalizare s-a avut n vedere indicaiile din STAS 8591,
privind distanele minime ntre diferite conducte, canale, cabluri subterane, etc.
Sistemul de canalizare urmeaz s fie executat din tuburi PVC cu cep i buz etanare cu
garnitur de cauciuc, racordurile se realizeaz cu elemente din aceeai material,
de bun calitate utiliznd tehnologii moderne astfel nct infiltraiile s fie
eliminate. Pe traseul conductei la schimbri de direcie pe orizontal sau pe
15

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

vertical s-au prevzut cmine vizitare i de splare ce se vor amplasa la


distane cuprinse ntre 30 60 m n funcie de: configuraia terenului, puncte
obligate, puncte de racordare.
Cminele de vizitare i de splare sunt amplasate la schimbri de direcie i n aliniament
dar la distane nu mai mari de 60 m, cminele de vizitare se execut din beton simplu,
amplasate la cca. 150 m, iar cminele de splare se execut din BS i se amplaseaz la
distane de cca. 50 m. Reeaua de canalizare s-a proiectat cu panta de scurgere ntre 0,5%
- 10%, se admite folosirea pantei minime de 0,3% pe tronsoane scurte, iar n situaiile n
care panta terenului este mai mare de 10% s-au prevzut cmine de rupere de pant. Apele
uzate menajere sunt colectate si evacuate n staia de epurare prin tuburi PVC cu diametrul
exterior 200 mm, 250 i 315 mm.
Datorit denivelrilor terenului pe traseul conductelor ce reiese din
topografice, se impune realizarea a 3 staii de pompare de ridicare de nivel.

msurtorile

ncrcarea apelor uzate evacuate n reeaua de canalizare menajer se vor ncadra n


prevederile NTPA 002-2005. n cazul n care, uniti generatoare de ap uzat ce se vor
executa n perspectiv care nu se pot ncadra n aceste valori, vor realiza o instalaie de
preepurare proprie, pentru a se ncadra n prevederile actului de reglementare de mai sus.
n prezent n localitate nu funcioneaz uniti generatoare de ap uzat cu indicatori de
calitate peste cele prevzute n NTPA 002-2002.
STAIA DE EPURARE
n documentaie s-a prevzut execuia unei staii de epurare mecano biologic cu nmol
activ pentru epurarea urmtoarelor debite caracteristice.
SCHEMA TEHNOLOGIC DE EPURARE
Schema tehnologic de epurare mecano - biologic, s-a elaborat avnd n vedere
urmtoarele considerente:
staia de epurare cuprinde obiecte tehnologice care s asigure evacuarea apelor epurate
sub indicatorii prescrise prin NTPA 001-2005. utilaje i echipamente trebuie s fie fiabile, s
aib un consum redus de energie electric, s fie avantajoase din punct de vedere al
cheltuielilor de exploatare i al investiiei; s cuprind obiecte tehnologice care s realizeze
reinerea eficient a deeurilor solide, care trebuie s ocupe volume ct mai mici i s fie
stabile din punct de vedere biochimic;
S-a luat n vedere extinderea staiei n funcie de evoluia demografic a localitii; s
permit descrcarea materialului septic vidanjabil provenit de la gospodrii izolate, a cror
racordare la reea de canalizare este dificil sau presupune investiii ridicate;pentru un
anumit obiect tehnologic se va adopta soluia cea mai potrivit din punct de vedere
tehnico-economic i care s se poat adapta cel mai uor condiiilor locale de spaiu, relief,
posibiliti de fundare, execuie etc.;schem de epurare simpl, dar s prezinte siguran n
exploatare i s nu necesite personal de nalt calificare.
Staia ocup o suprafa redus, sau utilizat soluii compacte, asigurndu-se un flux optim
att pe linia apei ct i pe cea a nmolului. Amplasarea obiectelor tehnologice trebuie s
conduc la o curgere pe ct posibil gravitaional, cu pierderi de sarcin reduse si cu
volume de beton i terasamente minime.
4. ACTIVITI DESFURATE PE AMPLASAMENT
PREZENTAREA ACTIVITII

16

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Activitatea specific a Punctului de Lucru Vlhia este exploatarea, ntreinerea , i


asigurarea ficionrii a instalaiilor de captare, tratare i distribuire a apei potabile n baza
Protocolului de Predare-primire din 02 august 2010, ncheiat de catre Operatorul
SC HARVIZ SA cu proprietarul acestor sisteme hidroedilitare cu Consiliul Local
Vlhia.
Activitatea desfurat
COD CAEN 4100 : Captarea, tratarea i distribuia apei
COD CAEN 9100 : Colectarea i tratarea apelor uzate
4.1

DESCRIEREA I FUNCIONAREA INSTALATIILOR

4.1.1 CAPTAREA TRATAREA SI DISTRIBUTIA APEI STATIA DE


TRATARE,
RETEA
DISTRIBUTIE
APA
POTABIL
4.1.1.1 ACTIVITATEA DESFURATA
Domeniul de activitate:
COD CAEN 3600: Captarea, tratarea i distribuia apei
Sistemul de alimentare cu ap potabil si canalizare menajera a oraului Vlhia a fost dat
n funciune n anii 1971-1972 conform Proiect nr. 1040/1969 elaborat de ISPGC Bucureti.
Lucrrile de construcii i montaj a obiectivului (cele dou captri, staia de tratare, reele
de aduciune i distribuie) au fost executate de fostul TCI Braov.
Astfel , n prezent sistemul de alimentare cu ap potabil este alctuit din captri de
suprafa de pe prurile Vrghi i Zmeuri cu o capacitate medie de 40l/s, care a fost
modernizat si dezvoltat
In staia de tratare se executa tratarea, decantarea si filtrarea apei.

Apa tratat este distribuit ctre consumatori printr-o reea de aduciune i distribuie cu
diametre cuprinse ntre 125 i 250 mm, cu o lungime de cca 28,945 km. Pe traseul
conductei s-au prevzut cmine cu regulatoare de presiune, cmine cu debitmetre, cmine
cu ventile de aerisire i traversri i subtraversri ale prului Vrghi.
Consumatori : populaie 12-22 l/sec,

17

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Populaie deservita 6.893 locuitori din total de


( conform anexei )

ORIGINAL
Pagina 1

7.043 locuitori , ageni economici 98

Capacitai, volume, debite apa autorizate.


Conform Autorizaiei de gospodrire a apelor nr 274/31.01.2012
Emis de
Administraia Naionala Apele Romane Administraia Bazinal de APA OLT rezulta
urmtoarele:
Indicatorii cadastrali de identificare a folosinei
Oraul Vlhia este alimentat cu ap potabil din dou surse de suprafa i anume din
prul Vrghi i Zmeuri, cod cadastral VIII-1-67-7 , care izvorsc din versantul sudic al
masivului munii Harghita.
Captare:
Suprafata
Pr Vrghi Hm 100, cod cadastral VIII.1.67.7
Pr Zmeuri Hm 14
Debitul instalat a celor dou captri:
Sursa Vrghi : Q max Vrghi =

70 I/s.

Sursa Zmeuri : Q max pr. Zmeuri = 80 I/s,


Volum si debite de apa autorizate :
Q zi max = 4000 mc - 46 l/sec anual 1460 mii mc
Q zi med = 2500 mc - 29 l/sec anual 912,5 mii mc
Q zi min = 1500 mc 17,5 l/sec anual 550 mii mc
Regim de funcionare; permanenta 365 zile/a , 24 ore/zi
INSTALAII DE CAPTARE
Apa de Suprafa pr. Vrghi
2 camere de captare cu priz, deznisipator i camere de sedimentare pentru un debit max.
de 70 l/s
Prag de fund pentru ridicarea nivelului apei
Diguri submersibile pentru dirijarea apei ctre priza de captare
Priz orizontal pe talvegul rului
Apa de Suprafa pr. Zmeuri
2 camere de captare cu priz, deznisipator i camere de sedimentare pentru un debit max.
de 80 l/s
Prag de fund pentru ridicarea nivelului apei
Diguri submersibile pentru dirijarea apei ctre priza de captare
Instalaii de tratare:
La staia de tratare se trateaz apa de la cele dou captri desfurnd urmtoarele
procese de tratare:
tratarea cu lapte de var i sulfat de aluminiu n soluie i silice activ n cazul temperaturilor
sczute
decantare suspensional

18

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

filtrare cu filtre rapide


Procesele de tratare se desfoar ntr-o singur construcie alctuit din camera de
amestec,
decantoare suspensionale cu D=5,8m, 4 cuve de filtre rapide cu S=12mp fiecare,
rezervoare ap pentru splare filtre, rezervoare de nmagazinare 2x500mc.

Instalaia de aduciune i nmagazinare a apei


Transportul apei de la cele dou captri se face prin 2 aduciuni din PVC cu Dn = 250 mm i
lungimea de L=1276m (de la captarea Zmeuri) respectiv cu Dn = 150 mm i lungimea de
L=600m (de la captarea Vrghi), pn la cminul de intersecie de unde apa este dirijat
spre camera de amestec a staiei de tratare printr-o conducta comun PVC cu DN250 mm L
= 19,5 m.
Apa tratat este nmagazinat n 2 rezervoare de 500 mc fiecare.
Reeaua de distribuie a apei potabile
Apa tratat este distribuit ctre consumatori printr-o reea de aduciune i distribuie cu
diametre cuprinse ntre 125 i 250 mm, cu o lungime de cca 28,945 km. Pe traseul
conductei s-au prevzut cmine cu regulatoare de presiune, cmine cu debitmetre, cmine
cu ventile de aerisire i traversri i subtraversri ale prului Vrghi.
Apa pentru stingerea incendiilor
Volum intangibil: 500 mc.
Debitul suplimentar acceptat pentru refacerea rezervei de incendiu din surse 9,14 l/sec din
prul vrghi i 5,9 l/s din prul zmeuri.
Volume de ap asigurate din surse: pentru alimentarea cu ap a folosinei
Surse de suprafa:
Zilnic mediu 2500 mc 29 l/s anual 912,5 mii mc
Modul de folosire a apei
Necesarul total de ap: maxim 4000 m 3/zi; mediu - 3000 m3/zi; minim 1500 m3/zi.
Cerina total de ap: maxim 4000 m3/zi; mediu - 3000 m3/zi; minim 1500 m3/zi.

19

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

4.1.1.2 DESCRIEREA
PROCESELOR
CAPTAREA TRATAREA APEI

ORIGINAL
Pagina 1

TEHNOLOGICE,

In condiiile de existenta a vieii, in general si de desfurarea activitatillor umane in


special, apa coninuta in diferite formaiuni hidrologice prezint o dubla importanta , prima
ca factor de mediu nconjurtor, respectiv de generatoare de sisteme ecologice, si a doua
de materie prima pentru anumite folosine ca: apa potabila, apa industriala, piscicultura,
agrement.
Calitatea apei necesare fiecrui tip de folosina este o problema de mare actualitate si se
afirma ca la ora actuala este factorul care decide orientarea alimentarilor cu apa. In afara
faptului ca aceasta calitate trebuie sa corespunda cerinelor consumatorilor, ea este cea
care stabilete si categoria de sursa de apa care poate fi folosita, precum si tehnologia de
tratare, necesara atingerii indicatorilor de calitate solicitai, factori determinani in
alctuirea unui sistem de alimentare cu apa.
Condiii de calitate a apei potabile
Conform diferitelor normative, indicatorii de calitate ai apei de but poate fi impartita in
urmtoarele grupe de factori : organoleptici, fizico-chimici, generali, indezirabili, toxici,
microbiologici, radioactivi, biologici.
Apa potabila livrata de SC Comunal SA trebuie sa respecte condiiile de calitate prevzute
in STAS-ul 1342-91 si trebuie sa asigure prin analize corespunztoare prescrise prin
standarde respectarea acestor parametrii de calitate.
Oraul Vlhia este alimentat cu ap potabil din surse de suprafa, i anume din
prurile Vrghi i Zmeuri, care izvorsc din versantul sudic a masivului munii Harghita.
Debitul instalat a celor dou captri sunt: pe prul Zmeuri 80 I/s, iar pe pr. Vrghi 70 I/s,
dar cu un debit mediu prelevat de 40 I/s. Captrile sunt dotate cu baraje de priz i camere
de priz cu hidroelevator (sistem vertical) i camere de aspiraie.
Transportul apei de la cele dou captri se face prin conducte de aduciune de Dn 150 mm.
Aduciunea Vrghi - staia de tratare este de 540 m iar Zmeuri staia de tratare este 1540
m. Ambele aduciuni sunt prevzute cu debitmetre Parshall.
Apele din cele dou aduciuni se unesc ntr-un cmin de intersecie de unde sunt conduse la
staia de tratare printr-o conduct cu Dn 250 mm.
La staia de tratare se execut urmtoarele procedee:
tratarea apei cu lapte de var si sulfat de aluminiu, silicea la nevoie, ( tratare cu reactivi)
urmnd decantarea in decantoare verticale suspensionale.
filtrarea apei decantate n 4 filtre rapide cu o suprafa de 12 m2 fiecare.
Apa filtrat este depozitat n dou rezervoare de 500 m 3 fiecare.
Staia de tratare este dotat cu un laborator propriu de analiz a calitii apei.
4.1.1.3 SISTEME DE CAPTARE
Sistemul de captare Vrghi
Cuprinde:
camerele de captare cu priza, deznisipatorul (sistem vertical) i camerele sedimentare a
particulelor pn la 0,2 mm, pentru debit max. 70 I/s
pragul de fund pentru ridicarea nivelului apei;
digurile submersibile pentru dirijarea apei ctre captare.
20

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Captarea const din 2 camere, cu funcionare independent, fiecare din ele putnd asigura
debitul de 70 I/s, ceea ce permite curirea lor de sedimente i separarea lor, fr a se
ntrerupe alimentarea cu ap.
Fiecare camer este prevzut cu cte 1 buc grtar vertical care acoper o fereastr de
1,20 x 0,35 m. Ferestrele sunt prevzute cu cte 1 buc stavil care comand accesul apei n
camerele de sedimentare sau permite prelevarea apei la diferite nivele, n funcie de nivelul
apei n pru.
Camerele sedimentare sunt de tip vertical i asigur sedimentarea particulelor pn la
0,2 mm. Pentru splarea camerelor s-au prevzut hidroelevatoare. Din camerele
sedimentare apa trece prin 2 ferestre prevzute cu grtare dese n camera de ncrcare a
conductei. nchiderea scurgerii din deznisipator ctre camera de ncrcare a conductei se
face cu un stvilar de tip 3. In aceast captare s-a prevzut i o priz orizontal pe talvegul
rului. Aceast priz este format din dou grtare orizontale duble, avnd un strat drenat
ntre ele, aezate pe o galerie de captare sub fundul prului. Prelevarea apei cu aceste
grtare n timpul apelor sczute i n special iarna cnd prul este ngheat este realizat.
nchiderea accesului apei prelevat cu aceast priz se face cu stavila de tip 2.
Pentru ridicarea nivelului apei n faa ferestrelor prizei de ap s-a prevzut transversal pe
pru un prag deversor din beton, cu dimensiuni de 1 m lime i 10 m lungime, care n
dreptul camerei de captare se termin cu o pil de 70 mm grosime. Pila se sfrete la 1,75
m distan de faa exterioar a captrii. Pe aceast distan de 1,75 m sunt dou stvilare
de tip 4, unul spre amonte i altul spre aval de priza pentru splarea aluviunilor din faa
prizei.
Sistemul de captare Zmeuri:
Este identic cu cea de pe prul Vrghi, cu deosebirea c nu are prevzut priza orizontal
pe talvegul pru lui i debitul maxim este de 80 I/s.
Aduciunea
Transportul apei de la cele dou captri - Vrghi i Zmeuri - se face prin dou aduciuni de
ap brut. De la captarea Vrghi apa este transportat printr-o conduct PVC cu Dn med
150 mm pn la cminul de intersecie. De la camera de priz pleac o conduct PVC cu Dn
mediu 150 mm pn la instalaia debitmetru Parshall, amplasat n aval de zona captrii.
Cota axului conductei la punctul plecrii este 950 m.
Apa trece prin instalaia de msurare a debitului, format din canalul Parshall,
acoperit cu plci din beton armat prefabricat i pmnt pentru a evita ngheul. nainte de a
exista canalul Parshall s-a prevzut o van montat n pmnt pe conducta, pentru reglarea
debitelor spre staia de tratare.
De la captarea Zmeuri pleac tot o conduct PVC cu Dn 150 mm pn la debitmetru
Parshall. De aici apa este trimis printr-o conduct PVC cu Dn mediu de 250 mm pn la
cminul de intersecie. Pe traseu sunt construite cmine de golire, cmine pentru ventil de
aerisire, masive de ancoraj la devierea pe orizontal i vertical, nglobate n beton la
subtraversri. Conducta este parial cu nivel liber i n aval sub presiune debitelor de
calcul, ca i ceea de la captarea Vrghi.
n ipoteza unor debite mai mari ce se pot obine dac exist debite de pe cele dou praie,
prin manevrarea celor dou vane de la debitmetre Parshall, cele dou aduciuni se pot pune
total sub presiune de la debitmetrele, n aval, lucrnd cu un debit sporit.
n cminele de intersecie apa de la cele dou captri se unete nainte de a ajunge n
staia de tratare. n cmin pe cele dou aduciuni s-au prevzut clapete de reinere pentru a
nu permite trecerea apei de la o captare la alta n cazul funcionrii unei singure captri.
Apele unite n cminul de intersecie sunt conduse spre camera de amestec cu reactivi prin
conducta PVC cu Dn mediu' 250 mm. n timpul exploatrii, prin intermediul vanelor

21

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

funcionale, n zona captrii exist posibilitatea reglrii debitelor de la captri i


corespunztor calitii apei n ceea ce privete turbiditatea.
Dac la o captare apa e mai tulbure se poate dirija un debit mai mare de la cealalt surs,
n cazul n care acolo apa este mai limpede.
4.1.1.4 STAIA DE TRATARE APA POTABIL
Sursele de apa conin o serie de impuriti in concentraii ce pot depii de multe ori
limitele de potabilitate , ori aa cum sa artat mai nainte apa de consum nu poate depii
anumite limite de concentraii , indicate in normele de potabilitate.
Sarcina de a ndeprta aceste impuriti revine staiei de tratare, care prin diverse
construcii si instalatii , realizeaz un lan de procese, flux tehnologic continuu , prin care in
final apa trimisa la consumator se nscrie in norme de potabilitate.

Pentru asigurarea calitatii corespunztoare in staia de tratare se folosesc urmtoarelor


procese de tratare :
sitarea pentru reinerea corpurilor si materialelor plutitoare antrenate de apa
resedimentarea se urmrete reinerea suspensiilor grosiere si a particulelor de nisip din
apa.
Corecia pH ul apei prin adugarea de lapte de var
coagularea si flocularea aglomerarea suspensiilor fine nedecantabile in flacoane ,care vor
fi uor sedimentabile
decantarea reinerea majoritii
suspensiilor din apa , prin aceeai procedeu de
staionare relativa, dar dupa faza de coagulare floculare.
Filtrarea pentru finisarea limpezirii , pentru reinerea particulelor si flacoanelor fine si a
microorganismelor.
Dezinfecia distrugerea tuturor microorganismelor
Prin metodele intensive de tratare a apei, accentul se pune pe folosirea a reactivilor chimici
si procedee mecanice cu randamente ridicate timpul de retenie al apei in instalatii este
scurt , in comparaie cu evoluia naturala a fenomenelor similare.
n conformitate cu studiul hidrochimic i cu soluiile de tratare analizate n
laborator s-a adoptat procedeul de decantare cu reactivi i filtrarea apei
decantate n filtre rapide.

22

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Staia de tratare este organizat ntr-o singur construcie i sunt adoptate urmtoarele:
tratarea apei cu lapte de var pentru corectarea pH-lui, ntruct studiul hidrochimic indic
agresivitatea apei asupra betonului i metalelor. De asemenea se prevede tratarea apei cu
sulfat de aluminiu n soluie i cu silice active n cazul temperaturilor sczute;
decantare suspensionala,
hal cu filtre rapide i sub ele rezervoarele de ap de splare, incluznd i rezerva de
siguran n caz de incendiu din ora.
n acest fel procesele de tratare s-au concentrat ntr-o singur construcie, totul fiind
acoperit, ferite de intemperii. Circuitul de tratare a apei: apa sosit de la cele dou captri
n cminul de intersecie este condus printr-o conduct de Dn 250 mm cu nivel forat spre
camera de amestec amplasat n hala decantorului suspensional.
Camera de amestec este format dintr-un tub exterior din beton, iar concentric un tub de
beton cu Dn 300 mm. In tubul concentric se termin conducta de Dn 250 mm de la cminul
de intersecie.
Apa sosit prin tubul central a camerei de amestec iese printr-o fereastr n partea
superioar, n spaiul dintre cele dou tuburi. Spaiul dintre cele dou tuburi - coroana
circular - Iat de 250 mm - are la fund beton de pant care face ca apa ieit prin fereastra
tubului exterior s curg pe culoarul periferic pe o pant foarte mare. Apa sosit la sfritul
cursei cu energie hidraulic mare se lovete de perete, formnd un salt hidraulic i pleac
spre decantarea de baz printr-o conduct de Dn 300 mm.
n camera de amestec sunt introdui reactivii corespunztori dozelor care sunt fixate
de ce le vor fixa analizele de laborator zilnice, i anume:
laptele de var;
sulfatul de aluminiu, n soluie i silicea activ.
Ele sunt introduse prin partea superioar a camerei de amestec.
Reactivii sunt preparai conform precizrilor de specialitate. Conductele pentru reactivi sunt
din PVC pentru a nu fi atacate de reactivi.
Apa brut mpreun cu reactivii curg la camera de amestec pe canalul circular periferic cu
pant mare, se lovesc de peretele frontale, tulburndu-se astfel nct s realizeze un
amestec bazat pe amestecarea pe principiul saltului hidraulic. De la camera de amestec o
conduct de Dn 300 mm conduce amestecul la decantoarele suspensionale. Dup primul
decantor conducta ce aduce apa brut amestecat cu reactivi i reduce diametrul de la
300 mm la 250 mm.
Decantoarele suspensionale sunt construcii cilindrice, cu fund tronconic, avnd diametrul
de 5,80 m la interior. Intrarea apei se face de sus printr-o conduct pn n centrul
decantorului, dup care coboar la fund i distribuie apa printr-o reea radial de conducte,
prevzute cu duze calibrate pentru un debit uniform pe suprafaa orizontal a decantorului.
La cota 930,82 m , deasupra sistemului de distribuie a apei brut s-a prevzut un fund
perforat pentru repartizarea i mai uniform a debitului n seciunea orizontal a
decantorului.
Spaiul de sub acest fund perforat constituie camera de reacie a decantorului.
Deasupra fundului perforat este spaiul de decantare propriu zis. n spaiul de decantare
suspensiile sunt meninute n masa lichid ului de curentul ascensional a apei i prin efectele
de aglomerare, n flacoane, care produc o limpezire mai bun a apei dect n celelalte
sisteme de decantare. n centrul decantorului concentric este un cilindru de beton pn la
cota 933,82 prin care se dirijeaz startul de suspensii la baza cruia prin intermediul unei
vane i conducte de golire se evacueaz la canal fluidul cu suspensii concentrate la baza
decantorului. La cota 932,82, n jurul cilindrului n interior s-a prevzut vane manevrate de

23

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

sus pentru reglarea stratului suspensional. Prin deschiderea lor se coboar nivelul acestui
start.
Colectarea apei se face prin jgheaburi radiale prevzute cu deversori triunghiulari.
Colectarea apei decantate din jgheaburile radiale se face jgheabul periferic, de la care
pleca conducta de ap decantat spre filtre.
Filtrarea apei
Filtrarea este un procedeu de separarea solidelor de lichide , prin care materiile in
suspensie sunt separate de lichide prin trecerea amestecului printr-un material poros
( filtrant ) , care rein materiile solide si se las sa treac lichidul.
Tipul filtrelor din dotare sunt: filtre rapide cu materialul filtrant folosit , nisipul cuaros cu
granulaie de 0,33 mm, iar grosimea stratului filtrant este de 90 cm.
Filtrele trebuie sa fie splate zilnic , aceasta apa pierduta reprezint 5-6 % din cantitatea de
apa tratata, si care se elimina din instalaie ) ( in funcie de anotimp, condiii de precipitaii
etc )
Pentru filtrare s-au prevzut 4 cuve de filtre rapide cu suprafaa de cte 12 mp. Filtrele sunt
de tip clasic alimentate cu ap brut decantat, cu apa de splare i aer separate cu
evacuarea apei filtrat i golirea filtrelor separat. Sistemul de colectare a apei filtrate se
face printr-un dispozitiv pentru nivel constant prevzut cu bazinele respective de ap
filtrat, cu sifoane corespunztoare principiului de funcionare a dispozitivului detaliat.
Vanele sunt acionate pneumatic de la pupitrele de comand amplasate pe planeul de la
cota 936,00 de peste culoarul de conducte.
Sub hala filtrelor s-a prevzut rezervorul cu dou compartimente pentru apa filtrat,
prevzut cu o camer subteran de vane. In acest rezervor este prevzut nmagazinarea
rezervelor intangibile pentru populaie. In camera vanelor s-a prevzut instalaia de
conducte pentru apa potabil ctre S.C. METALURGICA S.A. i ora. Golirea rezervoarelor se
face n canalul tehnologic prin care se evacueaz i apa de splare a filtrelor.
n sala pompelor s-a prevzut i s-au amplasat i pompe PCH pentru agitarea i pomparea
sulfatului de aluminiu depozitat n bazine subterane alturate staiei de pompare a apei de
splare. Tot la subsol s-a amplasat i sala hidroforului, a crui instalaie este compus din:
cazanul de hidrofor
reea aer pentru curirea i desfundarea conductelor de la decantoarele suspensionale
pompe pentru apa potabil (una n funciune i una rezerv)
pomp pentru hidrofor
2 buc. compresoare de aer.
Coborrea recipientelor de hidrofor se face printr-un gol prin centrala termic de deasupra.
Alimentarea cu ap potabil i cu apa rece pentru reactivi se face prin conducta de plecare
de la hidrofor. n cadrul organizrii construciei staiei de tratare ntre hala filtrelor i hala
decantoarelor exist un corp ale cldirii cu deserviri pe trei paliere: subsol - parter etaj.
Dezinfectarea apei
Apa distribuita pentru nevoi menajere si potabile ale populaiei nu poate trebuie sa fie
duntoare sntii oamenilor, deci nu poate conine bacterii patogene.
Dezinfectarea apei se realizeaz cu clorul gazos - operaia de clorinare.
Introdus in apa clorul acioneaz asupra substanelor organice care se gsesc in ea,
precum si asupra bacteriilor, distrugndu-le. In combinaie cu apa clorul formeaz acidul
hipocloros si acidul clorhidric. Acidul hipocloros fiind un compus nestabil se descompune,

24

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

mai departe in acid clorhidric si oxigen elementar (liber) Oxigenul liber acioneaz ca un
puternic oxidant asupra substanelor organice si a bacteriilor care se gsesc in apa.
Stabilirea corecta a dozei de clor este foarte importanta. Doza de clor ce urmeaz a fi
adugata se stabilete prin analize de laborator, privind proprietile individuale ale apei
care se corecteaz, pe baza experienelor fcute cu aceasta apa.
4.1.1.5 DISTRIBUIA APEI POTABILE
De la staia de tratare apa potabil este transportat printr-o singur conduct spre ora. Sau prevzut rezervoare de 2x500 mc. Pentru S.C. Metalurgica S.A. nmagazinnd rezerva
intangibil de incendiu corespunztoare i rezerva de avarii n cazul avariilor pe aduciunea
de la staia de tratare.
Aduciunea staia de tratare - rezervoare 2 x 500 mc s-a dimensionat la Q zi max i
numai conducta de la ezervoare S.C. Metalurgica S.A. sunt de Dn 300 mm, care este
dimensionat la debitul maxim orar, n ipoteze de incendii n Metalurgica S.A. Lungimea
acestei conducte este de cca. 600 m. Aduciunea de la staia de tratare la rezervoarele de 2
x 500 mc este din oel i are diametru nominal de 219 mm n amonte i 250 mm n rest. Pe
traseul aduciunii pn la rezervoarele s-au prevzut cmine cu debitmetre, cmine pentru
regulator de debit, cmine pentru ventile de aerisire. La traversrile canalului Vrghi s-a
prevzut nglobarea n beton a conductei iar la subtraversri ancorare de pod sau sub pod
cu izolare termic a conductei cu vat de zgur. Deoarece aduciunea pe traseu transport
apa potabil ntre cote ce depesc coloana de ap s-au prevzut pe traseu, n puncte
calculate, reductoare de presiune.
De la ramificarea spre S.C. Metalurgica S.A. a aduciunii n aval alimentarea S.C.
Metalurgica S.A. i restul oraului se face prin intermediul rezervoarelor de 2 x 500 mc, care
servesc c rezervoare de trecere n cadrul alimentrii cu ap se face cu conducta de 219
mm,dimensionat la Q zi max. Traseul aduciunii de ap potabil este pe artera principal a
oraului iar traseul conductelor spre rezervoare i napoi este lateral spre un versant.
Ramificarea spre rezervoare se face din aduciune, n apropierea S.C. Metalurgica S.A.
iar conducta de la rezervoare spre Metalurgica S.A. i restul oraului sosete tot n
apropierea punctului de ramificare i continu traseul pe artera principal, deci trecerea
prin rezervor este un ocol de aproape 1,5 km, spre a se ntoarce n acelai punct. n caz de
avarie la rezervoare sau la conductele de 219 mm i 300 mm la i spre rezervoare s-a
prevzut i alimentarea direct din aduciunea de 250 mm de, la staia de tratare,
scurtcircuitnd rezervorul, n conformitate cu schema de alimentare cu ap i cu notele de
calcul pentru liniile piezometrice n diverse ipoteze amplasamentele regulatoarelor de debit
(n numr de 3) sunt astfel alese ca i la presiunea static s nu se depeasc 60 mm
coloana de ap.
Aduciunea de la rezervor, conducta de 300 mm se reduce dup primul branament uzinal
la 175 mm pn la a doilea branament uzinal care completeaz numai consumul
tehnologic de ap. Dup aceast se reduce diametrul ntruct n aceast zon se
amplaseaz al treilea cmin cu regulator de presiune i este convenabil strangularea
respectiv. Dup aceste instalaii conducta de aduciune revine la Dn 125 mm pn la
captul aval a oraului.
Pe traseul aduciunii s-au prevzut:
cmine cu regulatoare de presiune cmine cu debitmetre - pentru cazul defectrii
contoarelor a fost prevzut bypass de ocolire a contoarelor cmine cu ventile de aerisire n
puncte ridicate la intersecia cu canalul Vrghi, care parcurge tot oraul n zona arterei
principale Vlhia - Lueta s-au prevzut subtraversri, ocolind podurile.
Rezervoare de 2 x 500 mc:
Rezervoarele de 2 x 500 mc, cuprinznd volumul de compensare, rezerva intangibil de
incendiu i volumul de avarii pentru S.C. Metalurgica S.A. sunt amplasate pe versant, n
25

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

zona blocurilor din ora, cota maxim a apei fiind la 853,00 n cota absolut. n camera
vanelor s-a prevzut instalaii de incendiu cu 2 buc vane electrice pe conducta de 219 mm.
Acionarea acestor vane este de la S.C. Metalurgica S.A., de la staia de pompare circular.
Pe conducta de alimentate a rezervoarelor s-a prevzut robinete cu flotor pentru a nu avea
pierderi de ap prin preaplin.
Reele de ap:
Au fost prevzute reele pentru zona blocurilor de locuine, dotate cu hidrani de incendiu i
fntni de strad, ns au fost realizate doar hidrani de incendiu la punctele vulnerabile din
ora (strzile Gabor ron, Eminescu, tineretului, Turitilor etc). n zona spitalului s-a
prevzut doar aduciunea. n partea de sus a oraului nu s-a prevzut hidrani de incendiu
dar ulterior au fost montai 4 buc. n diferite zone stabilite de Consiliul Local.
4.1.1.6 DOTRI
Captarea de mal cu prag de fund pe prul Vrghi
Dimensiunile exterioare al captrii sunt 3,40 x 5,10 m si este prevzuta cu 2 camere
independente, cea ce permite curatirea lor de sedimente si reparaii , fara a ntrerupe
alimentarea cu apa. Peretele din spre apa a captrii este prevzuta cu ferestre de priza de
apa verticale , cu dimensiuni de 1,20 x 0,3 m, pentru fiecare camera independenta .Fiecare
fereastra este prevzuta cu stavila care comanda accesul apei in camere de sedimentare
permind prelevarea apei la diferite nivele in funcie de nivelul apei din parau. Lungimea
aduciunii 800 m. Capacitate 80 l/sec.
Suprafaa totala a terenului aparinnd captrii Vrghi 6764 mp (conf. Plan anexat)
Captarea de mal cu prag de fund pe pr-ul Zmeuri
Dimensiunile exterioare al captrii sunt 3,40 x 4,95 mp si este prevzuta cu 2 camere
independente. Captarea a fost dimensionata tot la un debit de 80 l/sec.
Lungimea aduciei 1600 m.
Structura captrilor:
Dimensiunile celor doua construcii sunt identice.
Constructiile sunt din zidrie de crmida. Planeul de acoperi este din placa de beton
armat monolit. Uile sunt metalice. Pardoseala din ciment.
Suprafaa totala a terenului aparinnd captrii Zmeuri este de
anexat)

4055 mp (conf. Plan

Staia de tratare a apei


Incinta staiei de tratare are o suprafaa totala de 3.135 mp si adpostete urmtoarele
construcii:
staia de tratare o cldire cu 2 nivele Sc = 480,04 mp
opron cu Sc =80,14 mp
magazii (3 magazii cu Sc = 51,0 mp)
suprafaa total construita 612,31 mp
Cldirea principala - cldirea staiei de tratare este compusa din 3 corpuri:
Corp central cu S+P+E nivele
Corp filtre
Corp decantoare.

26

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Structura de rezistenta a cldirii: fundaie tip radier general , stlpi din beton armat, perei
din caramida planee din grinzi si placi din beton armat. Acoperi, structura din lemn
acoperit cu placi ondulate de azbociment.
Din punct de vedre funcional staia de tratare se compune din:
La subsol:
sala pompelor,
bazine de coagulant,
atelierul mecanic,
sistemul hidrofor.
La parter sunt amplasate:
Decantoarele,
Galeria de conducte,
Filtre (cuva filtrelor),
Centrala termica,
Instalaia de clorinare cu depozitul de butelii,
Depozitul de var,
Depozit de sulfat de aluminiu,
Atelier electric.
La etaj:
Sala filtrelor (partea superioara, cu acces),
Preparare dozare sulfat de aluminiu coagulani , var pt corectarea pH si silicea,
Compartiment administrativ : birou sef staie, dispecer, vestiar, sala de mese,
Laborator, sala de balane, depozit.
Decantoare suspensionale sunt compuse din 2 bazine construite din beton armat cu
fund conic avnd diametru de 5,80 m x 7,10 m, care primesc apa prin intermediul unui tub
central montat in partea inferioara, cu reea de distribuie perforata.
In acest spaiu se adaug reactivi
(chimicalele) necesare procesului de tratare. Din
spaiul de reacie, apa prin circulaie verticala trece in spaiul de decantare.
Staia de coagulare; Instalatii pt preparare dozare a reactivilor:
Vas pentru prepararea soluiei de hidroxid de calciu, concentraie de 30 mg/l CaO;
Vase pt prepararea soluiei de sulfat de aluminiu in concentraie de 6 %;
Vase pentru prepararea de silice active;
Pompe ( 2 buc ) pentru recirculare si pompare spre vasele de diluare sulfat de aluminiu in
vasele de silice activate.
Instalatii de filtrare: 4 filtre dreptunghiulare din beton de cate 12 mp fiecare. Materialul
filtrant folosit este nisipul cuaros cu granulaie de 0,33 mm, iar grosimea stratului filtrant
este de 90 cm. Filtrele sunt de tipul filtre rapide. Apa intra in partea superioara si iese sub
stratul de nisip prin crepine.
Instalatia de splare a filtrelor este compus din 2 pompe de sptare tip Cris 200 cu un debit
de 400 mc/h, H = 12 m, P = 30 Kw, 2 suflante SRD 2 A cu Q = 1300 mc/h.
Staia de clorinare. Este compus din depozitul de butelii de clor ( rezervor de clor ),
cntar, si instalaia de dozare tip Solway si Edvance.

27

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Sistemul de dozare a clorului gazos

Rezervor de clor lichefiat


Rezervor de inmagazionare apa tratata: amplasat subteran, construit din beton armat
si are o capacitate de 1000 mc., constituie si ca rezerva pt stins incendii.
Laboratorul chimic
Procesul tehnologic este condus in baza analizelor efectuate asupra apei brute intrate in
staie, in funcie de parametrii fizico chimici si organoleptici ai apei brute intrate adugarea cantitilor de chimicale, neutralizant, coagulant, silice, dozarea clorului gazos.
Livrarea apei potabile tratate consumatorilor este posibila dupa efectuarea analizelor
necesare in vederea verificrii respectrii ncadrrii in prevederile calitative.

28

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Laboratorul este dotat cu pH-metru, turbidimetru, etuve, cntare, balana analitica, aparat
distilat apa, termometre, densimetre, sticlrie pt analize, reactivi necesari.
Buletine de analize anexate documentaiei
Centrala termica: este dotata cu un cazan de nclzire centrala funcionnd cu lemn de
foc sau deeu lemnos. Consumul orar de lemne de foc in sezonul rece este de cca 30 kg/h.
Elementele coului de dispersie H = 9,5 m , S= 0,04 mp.
Instalatii de ventilaie. Se realizeaz natural, iar la clorinare este si ventilalatie artificiala.
REEA DISTRIBUIE
Lungimea reelei de distribuie 13,6 km, si este amplasata la o adncime de 1,5 m:
presiunea apei in reea este de 4,3 atm, cu distribuire continua.
Cmine de vizitare: cu forme dreptunghiulare, turnate din beton cu suprafee intre 1-2 mp
si adncime intre 1,5-2 m .
INDICI DE PLAN GENERAL
Suprafaa totala a terenului este de: 13.955,58 mp si este in proprietatea Consiliului
Local Vlhia.
Obiectiv
Suprafaa Suprafe
Suprafaa
Suprafaa
Suprafaa
totala
e
reea
transp.
libera
construc
ii
Captare Vrghi
6.764,97
61,34
6.703,63
0,00
0,00
Captare Zmeuri
4.055,54
30,03
4.025,51
0,00
0,00
Staia de tratare
3.135,07
612,31
28,64
2.494,12
0,00
Total
13.955,58
704,68
10.757,68
2,494,12
0,00
4.1.1.7 BILANTUL DE MATERIALE
Apa potabila livrata populaiei in acest caz considerat cu un produs pt populaie si ageni
economici, asigurarea necesarului fiind prescris prin normele legale, asigurate prin
instalaiile si dotrile prezentate mai sus , la calitate prescrisa prin standarde.
Populaia deservit este de 6893 locuitori din cei 7043 populaia total iar ageni economici
n numr de 98. Marea majoritate a consumatorilor sunt contorizai.
Necesarul i cerina de ap potabila se prezint n felul urmtor:
Necesarul total de apa:
Q
Q
Q

= 4000 mc/zi = 46,0 I/s


=
2500 mc/zi = 29,0 I/s
med
minx = 1500 mc/zi = 17,5 I/s
max

Cerina totala de ap:


Q
Q
Q

= 4000 mc/zi = 46,0 I/s


med = 2500 mc/zi = 29,0 I/s
minx = 1500 mc/zi = 17,5 I/s
max

Acest debit de apa se asigura din cele dou surse n felul urmtor:
Din sursa Vrghi:
Q
Q

= 1803 mc/zi = 20,50 I/s


med = 2200 mc/zi = 25,12 I/s
min

29

TOTAL PROIECT SRL


ODORHEIU SECUIESC

max

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

= 2455 mc/zi = 28,55 I/s

Din sursa Zmeuri:


Q
Q
Q

= 880 mc/zi = 10,17 I/s


med = 1072 mc/zi = 12,41 I/s
max = 1197 mc/zi = 13,85 I/s
min

Cantitatea de apa livrata la diveri consumatori este contorizata.


Instalaii de msurare a debitelor si volumelor de apa
Captare aduciune:
1 buc D = 200 mm tip Zenner
1 buc cu D = 150 mm tip Zenner
1 buc cu D = 80 mm tip Meineke cu verificare metrologica valabila
Produse chimice folosite:
oxid de calciu ( var )
Sulfat de aluminiu

cca 500 kg/luna - 6 to/an


cca 500 kg/luna - 6 to/an

clor

cca 150 kg/luna

- 1,8 to/an

chimicale pt laborator de analize


Alte materiale folosite:
piese metalice pt. reparaii cca. 1 to/an.
oxigen, carbid pt. sudri.
ulei si vaseline de ungere cca .200 kg/an.
Produse chimice periculoase si toxice.
Clorul lichid , in butelii sau conteiner special aparinnd furnizorului.
Cantitate maxima in unitate: 500 kg.
Fisa tehnica de securitate anexat documentaiei
Substane toxice si periculoase folosite in laborator, conform aprobrilor anexate
documentaiei. Autorizaie nr 2618/din 04.11.2003 pt deinerea si utilizarea substantelor
toxice
Aviz prealabil pentru operaiuni cu precursori categoria I pt permanganat de potasiu.
4.1.1.8 UTILITATI
Alimentarea cu apa: din sistemul descris mai sus
Consumatorii sunt:
populaie: 12-22 I/s.
ageni economici, instituii publice, etc.:17-21 I/s.
Apa
219
S.A.
500

tratat este distribuit ctre consumatori prin conducte de oel cu Dn 168 mm i Dn


mm pe o lungime de 7540 m. Conducta de 168 mm deservete direct S.C. Metalurgica
i are o lungime de 5420 m. La captul conductelor sunt dou rezervoare tampon de
m3 fiecare.

Apa potabila pentru consumul propriu


In baza breviarului de calcul nr.1 necesarul de apa in scopul igienico sanitar este de
30

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Q zi med = 0,640 mc/zi


Apa tratata pentru splarea filtrelor este in medie 120 mc/zi ( filtrele se spla zilnic ), care
se evacueaz in paraul Vrghi.
Asigurarea energiei termice
Energia termica pt sezonul rece se asigura cu cazanul de nclzire, consumul maxim de
lemn de foc pt. nclzire este de cca. 30 kg/h. Elementele coului de dispersie H = 9,5 m De
= 0,35 m.
Asigurarea energiei electrice
Energia electrica se asigura din sistemul naional, prin transformatorul de 250 KVar instalat
in unitate. Intretinerea, schimbarea uleiului este realizat de SC Electrica SA pe baza de
contract.
4.1.2 COLECTAREA
SI
TRATAREA
APELOR
CANALIZAREA MENAJERA ORASENEASCA

UZATE

Activitatea desfurata.
Domeniul principal de activitate:
COD CAEN 4100: Colectarea si tratarea apelor uzate
4.1.2.1 COLECTAREA
APELOR
MENAJERA ORAENEASCA

UZATE

CANALIZAREA

Reeaua de canalizare
Reea de canalizare: este realizat n sistem divizor. Reeaua de canalizare este realizat din
tuburi de beton, cu diametrul de 300 mm (n lungime de 1400 m) i 200 mm (n lungime de
3300 m). Lungimea total a reelei de canalizare este de circa 4.7 km i deservete 2,200
de locuitori, 7 instituii, 85 de uniti industriale i dou blocuri, adic 34% din strzile pe
care exist alimentare cu ap.
Monitorizarea calitii apei uzate de-a lungul sistemului de canalizare se face prin
prelevarea de probe din cminele de racord a acestor ageni economici. Prelevarea se face
cu o frecven lunar. Parametrii de calitate analizai sunt: Materii n suspensie, reziduu fix,
azot total, extractibile, detergeni, CCB5, CCOCr, iar procentul de analize conforme/an este
de 83%. Se pare ca de-a lungul reelei de canalizare exist zone n care, datorit strii
conductelor, apa freatic ptrunde n reea producnd diluia apei uzate la intrarea n staia
de epurare. Aceste zone, n prezent, nu pot fi determinate cu precizie din cauza lipsei de
aparatur adecvat. Pe viitor se va ncerca identificarea zonelor respective i poziionarea
pe hart, pentru investiii ulterioare. n acest moment singura monitorizare pe reeaua de
canalizare se face n cminele de racord a agenilor economici posibili poluatori. n cazul
unei poluri accidentale vor lua probe din emisar.
Staia de epurare ora Vlahia

31

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Staie de epurare:
Staia de epurare tip BNA cu stabilizarea nmolului cu o capacitate de 16 l/s.
Canal de msura din beton L = 11 m prevzut cu Camin de capt.
Grtar.
Bazin de aerare si decantare, construcie din beton armat cu dimensiunile de 17 x 16,60
x3,55 mc, prevzut cu jgheab central care se realizeaz accesul apelor uzate menajere in
bazin si doua jgheaburi marginale pentru ieirea apei decantate.
Aerarea se realizeaz cu ajutorul a doua turbine cu 750 rot/min.
Nmolul depus in decantoare este evacuat prin sifonare prin 4 conducte in 4 cmine de
nmol de unde este introdus in bazin de depozitare.
Din depozitul, nmolul este pompat cu o pompa ACV 80 la halda de zgura a uzinei SC
Metalurgica Vlhia SA.

Are un laborator pentru analizele de ap uzat la staia de epurare. Laboratorul pentru


uzat este dotat cu pH-metru, balan analitic, etuv electric, incubator, aparat de distilat
ap. La laboratorul de ap uzat se analizeaz material n suspensie, reziduu fix, azot total,
extractibile, detergeni, CCB5, CCOCr. Laboratorul este deservit de 2 laborani. Laboratorul de
32

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

analize va fi ridicat la standarde europene prin programul ISPA i va fi acreditat conform ISO
17025.

Instalaii de msurare a debitelor canal Parschal la staia de epurare

Sisteme reinere a plutitoarelor

33

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

TOTAL PROIECT SRL


ODORHEIU SECUIESC

ORIGINAL
Pagina 1

Sistemul de colectare a apei uzate din Vlhia este separativ deservind n general zona
central a oraului respectiv strzile: Gabor Aron, Spitalului, Jozsef Attila, Teilor si cartierul
M. Eminescu.
Lungimea total a reelei de canalizare menajer este de 4,7 km, conducte din beton i
azbociment cu diametre de la 200 pn la 300mm.

Laborator
Reeaua existent deservete aproximativ 2200 de locuitori, 7 instituii, 85 de uniti cu
caracter industrial i dou blocuri. Rata de conectare este de 27%.
Detalii privind caracteristicile reelei sunt date n tabelul de mai jos .
Material utilizat n reeaua de canalizare (situaia actual) Vlhia
Tabel nr. 2
Nr.

Diametrul

1
2

200 mm
300 mm

Lungimea reelei
Beton / Azbociment
*
3,300 m
1,400 m
Total lungime

PVC/PE/PP

Lungime total
3,300 m
1,400 m
4,700 m

n prezent se afl n faz de finalizare un proiect finanat prin OG7 pentru


dezvoltarea reelei de canalizare menajer.
n tabelul urmtor sunt prezentate strzile pe care s-a realizat sau este n curs de realizare
extinderea reelei de canalizare menajer.
Strzile incluse n extinderea realizat prin OG7 Vlhia
Tabel nr. 3
Strada
Nr.
Crt.

Denumirea strzii

OG 7/2007

Lungim
ea
strzii
(m)

Realiza
t
1.050
400

1
2

Harghitei
colii

1.050
400

Voinei

450

170

Observaii

n curs
de
execui
e
-

Diametru
(mm)

Material

200
200

PVC
PVC

200

PVC
34

TOTAL PROIECT SRL


ODORHEIU SECUIESC

4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Turitilor
Vitusok
Intr. Vitusok
trandului
Uzinei
Berentyi Margit
Marton Aron
Turntorilor
Noua
Ady Endre
Dozsa Gyorgy
Gyertyanffy Jonas
Spicului
Cmpului
Tineretului
Primverii
Sportivilor
1 Mai
Lupului
Carpailor
Aurora
Vntorilor
Republicii
M. Koglniceanu
Fagului
Bethlen Gabor
TOTAL

900
250
140
800
620
880
200
360
220
580
540
380
200
200
800
410
300
750
120
380
800
450
670
220
150
930
14.150

900
250
140
604
704
1.265
408
222
201
580
540
380
200
157
800
381
204
219
98
380
800
210
153
408
942
12.766

195
1176
83
1.454

200
200
200
110
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
110-200
63-200
200
200
200

ORIGINAL
Pagina 1

PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC

Executarea lucrrilor pe reeaua de canalizare menajer in zonele centrale, de nord i nord


est, vor soluiona n bun msur problema pentru aceste cartiere. Extinderea reelei de
canalizare n partea de sud dar i ntregirea acesteia n celelalte zone, face parte din
Proiectul POS Mediu.
Materialele predominante pentru conductele vechi de canalizare ap uzat sunt betonul i
azbocimentul. Pentru tronsoanele noi realizate s-a utilizat PVC.
Rata de conectare dup realizarea lucrrilor n curs va fi n jur de 63.8% din trama
stradal i aproximativ 78% din populaie.
Cea mai veche reea de canalizare dateaz din 1965.
Tabelul -1Vrsta conductelor in Vlhia:
Tabel nr. 4
Anii
Intre 1965 1980
Intre 1980 - 2000

Procent (%)
78
22

ntreaga reea de canalizare veche este gravitaionala, cu excepia strzii Spitalului pentru
care a fost amplasata o staie de pompare actualmente dezafectat.
Pentru extinderile reelei de canalizare n execuie sunt prevzute trei staii de pompare,
amplasate pe strzile Vntorilor, pentru zona de nord-est a oraului, trandului pentru
zona central i Ora-trand pentru zona median.

35

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Numrul total al conectrilor este 91, cu 45 pentru blocuri, 18 pentru case si 28 pentru
unitile economice.15% din apa uzata colectata zilnic este industriala. Dup realizarea
extinderilor incluse n programul OG7, se vor aduga nc 285 de conectri pentru case.
Colectorul principal Dn 300 mm amplasat pe strada Gabor Aron este n mare parte avariat
fiind strpuns pe un tronson de peste 500 m de rdcinile arborilor din zon, fapt ce a
condus la creterea debitului infiltraiilor i la obturarea seciunii de curgere.
In conformitate cu Autorizaia de Gospodrire a apelor:
Debite caracteristice
Homorodul Mic

apelor uzate

evacuate in receptori naturali: pr.

Q zi max = 1400 mc/zi = 16,0 l/sec;


Q zi med = 1300 mc/zi = 15,0 l/sec;
Anual 474,5 mii mc.
Categoria apei: Ape uzate urbane
Indicatorii de calitate apelor
NTPA 002/2005

uzate influente in stemul de canalizare: Conform

Indicatorii de calitate apelor uzate efluente i staia de epurare evacuate in pr.


Homorodul Mic
Tabel nr. 5
Categoria apei
Urbane
Emisar Homorodul Mare

Indicatorii de calitate
pH
Materii in suspensie
CBO5
CCOcr
Detergeni sintetici
Azot total
Reziduu filtrat la 105 oC
Subst. extr. cu solveni
organici

Valori
mg/l

maxime

admise

6,5-8,5
120,0
150,0
250
2.0
30,0
1000
20,0

Situaia existenta a reelei de canalizare, inclusiv extinderile cuprinse in OG 7, este


prezentata in planul urmator:

36

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Reea de canalizare - situaia existenta Vlhia

37

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Parametri reelei de canalizare din Vlhia:


Tabel nr. 6
Articol
3.6.1
3.6.1.1
3.6.1.2
3.6.1.3
3.6.2
3.6.2.2
3.6.3
3.6.4

3.6.5.1
3.6.5.2

3.6.9

Procent din lungimea sistemului mixt

Valoare
18,92

Uniti

00,0

% of
3.6.1
% of
3.6.1
% of
3.6.1
km
% of
3.6.2

100,00

Procent din lungimea sistemului separat


Procent din lungimea sistemului parial mixt/separat
Lungimea colectorilor principali
Procent din colectorii principali reabilitai
(legat de
colectorii principali existeni)
Numrul de staii de pompare a apei uzate inclusiv cele
executate sau n curs de execuie

0
1,6
0
4
0,40

Capacitatea staiilor de pompare a apei uzate

3.6.5

3.6.7

Indicator
Lungimea totala a reelei de canalizare (inclusiv colectorii
principali & proiectele n derulare)

Lungimea reelei de canalizare (fr apa pluviala si


colectori principali)
Lungimea reelei de canalizare reabilitata
Procent din reeaua de canalizare reabilitata (legat de
reeaua existenta)
Populaia deservita pe lungime de reeaua de canalizare
Capacitatea bazinelor de reinere a apelor pluviale

17,32
0
0
264
0

km

numrul
1000
m3/d
km
km
% of
3.6.6
capita/k
m
1000*m

Staii de pompare a apei uzat


n prezent exist o staie de pompare i nc trei n execuie care preiau apa uzata menajer
i industrial pompnd-o n reeaua de canalizare menajer. Poziionarea lor este dup cum
urmeaz:
SP veche amplasat pe strada Spitalului este neutilizat n prezent, neechipat, necesitnd
lucrri de reabilitare la structura de rezisten, refacerea alimentrii cu energie electric,
colectnd apa uzat de pe strada pe care este amplasat;
SP 1 n partea de nord a oraului pe strada Vntorilor colectnd ap uzat menajer de pe
strzile Carpailor, colii i Vntorilor Q=14 mc/zi;
SP 2 n partea de mijloc a oraului pe strada ora-trand colectnd ap uzat menajer de
pe aceast strad Q=6 mc/zi;
SP 3 nou n zona centrala a oraului, la captul strzii trandului colectnd ap uzat
menajer din zonele de nord i parial de mijloc inclusiv de pe strada pe care este
amplasat Q=72 mc/zi;
Staiile de pompare a apei uzate nu au o sursa alternative de energie.
Principalele caracteristici si valori ale staiilor de pompare existente sunt date in urmtorul
tabel:
Valori ale staiilor de pompare existenta din Vlhia:
Tabel nr. 6
No

Numele
staiei de

Num
rul de

Q
m/h

Hp

Eficient
a

Anul
instalri

Evaluar
ea

Evaluar
ea
38

TOTAL PROIECT SRL


ODORHEIU SECUIESC

pompare

1
2

PS veche
(str.
Spitalului)

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

pomp
e

energiei

N.A.
1965

1.5
N.A.
2008
kW
3
1
5.0
5M
1.5
N.A.
PS 2
2008
kW
4
1
5.0
5M
1.5
N.A.
PS 3
2008
kW
*Este prevzut o pomp n rezerv rece cu caracteristicile menionate
PS 1

5.0

5M

4.1.2.2 TRATAREA APELOR UZATE


ORASENEASCA

condiiil
or fizice
a
echipa
mentulu
i E&M
Nu este
echipat

buna

ORIGINAL
Pagina 1

condiiil
or
construc
iilor
civile
proast
buna

buna

buna

buna

buna

- STATIA DE EPURARE

Staia de epurare este de tip mecano - biologic i are capacitatea proiectat de 16 l/s, care
ns nu este de ajuns n momentul de fa, mai ales cnd partea nordic a oraului va fi
racordat la acest sistem. Este dotat cu debitmetru Parshall, - 1 bazin de aerare,- 2
aeratoare i pompe de nmol.
Nmolul depus de la decantoare este scos prin sifonare prin 4 conducte in 4 cmine si din
acestea prin gravitaie este introdus intr-un bazin de depozitare.
Din depozit nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a uzinei SC
Metalurgica SA, sau vidanjarea periodica sau transportarea acestora pe fnee.
Evacuarea apelor uzate se realizeaz n prul Homorodul Mic.
Nr. personal angajat : 4

persoane

Regim de lucru 24 ore/zi , 5 zile/saptamana, 365 zile/an


Investiia a fost executata in anul 1972, dupa tehnologia de la ceea vreme , din echiparea
staiei lipsind unele componente eseniale pt o funcionare eficienta , iar la stabilirea
parametrilor de evacuare sau luat in calcul diluia dupa evacuare in Homorodul Mic
( conform D.C.S. 414/1979 ) fiind stabilite valori relativ ridicate , ori prin apariia NTPA
001/1997 respectiv NTPA 001/2002,cat si NTPA011, legislaia impune noi masuri de
imbunatatirea a parametrilor de evacuare.
Totodat este necesar de artat ca obiectivul o are o capacitate mult mai mica
dect ceea ce este necesar localitii in prezent, innd cont ca o mare parte a
localitii nu este canalizata , totodat nu este rezolvata nici problema nmolului
stabilizat.
Staia de epurare lucreaz la un randament sczut, in (comparnd analizele realizate, fata
de valorile NTPA 001/2005) aceste valori se situeaz n jurul valorii de 20-40 %, totodat nu
este rezolvat n cadrul staiei deznisiparea, degresarea, decantarea prealabil apelor uzate
influente, i dezinfectarea apelor epurate efluente, totodat prezint o problem i
evacuarea i depozitarea nmolului stabilizat.
Apele uzate efluente din staia de epurare au un coninut ridicat de
Azot
amoniacal, CBO5, CCO cr fata de valorile admise prin Normativul sus amintit , dar
in autorizaia de Gospodrire a apelor nr 274/31.01.2012 innd cont de condiiile

39

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

concrete din zona orasului Vlhia


sunt admise valori mai largi in aceasta
perioada de realizare a dezvoltrii staiei de epurare.
4.1.2.3 DESCRIEREA PROCESELOR TEHNOLOGICE
Procesul de epurare
Staia de epurare reprezint un ansamblu de construcii instalatii si echipamente , pentru
realizarea epurrii apelor uzate , astfel incat sa respecte condiiile cerute de NTPA
001/2005, de evacuare a apelor uzate in emisari , sau NTPA 002/2005 ,de evacuare in
reele publice de canalizare.
Epurarea apelor uzate menajere se realizeaz printr-o serie de procese fizice, biologice, etc
care se desfasoara conform unei tehnologii, in funcie de caracteristicile apelor uzate
(concentraie, substane nocive, natura lor, debite ape uzate, etc.) si a gradului de epurare
necesar. Prin aceste procese, se urmrete ndeprtarea substanelor in suspensie ,a celor
coloidale din soluie , de natura organica si anorganica, a substanelor nocive, a bacteriilor
patogene in scopul protejrii sanatatii oamenilor si mediului ambiant.
Procedeul de epurare este mecano-biologica folosete activarea unor microorganisme ,
care oxideaz sau mineralizeaz substanele organice aflate in apa uzata. Aceasta epurare
este precedata de epurare mecanica, al crei scop este ndeprtarea impuritilor grosiere.
Tehnologia de epurare biologica, folosete fenomenul de biomasa in suspensie ( bazine cu
nmol activat ) .Din punct d vedere al eficientei de epurare , aceasta este o aerare
prelungita, cu stabilizarea nmolului ( denumit impropriu, oxidare totala ).

Schema tehnologica de epurare


Schema de epurare folosita urmrete in mod special reinerea materiilor in suspensie, a
substanelor flotante, eliminarea substanelor biodegradabile exprimate prin CBO 5.
Obiectele tehnologice sunt comasate in trei grupuri
linia apei
linia nmolului
construcii si instalatii auxiliare
Fluxul tehnologic pe linia apei consta din:
grtar rar
debitmetru Parshal
camera de distribuie
bazin de aerare cuplat cu decantor secundar
canale si conducte de legtura
Fluxul tehnologic pe linia nmolului
concentrator de nmol
pompe de evacuare nmol
pompare finala a nmolului
conducte tehnologice de legtura
Faze tehnologice de lucru:
Prin epurarea mecanica are loc ndeprtarea in principal a materiilor in suspensie si a
substanelor separabile gravitaional, realizat cu ajutorul grtarului de reinere. Materiile
40

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

solide colectate se colecteaz in pube nchise si se transporta pe platforma de deseuri


menajere.
In bazinul de aerare, oxigenul necesar meninerii condiiilor vitale ale bacteriilor din cadrul
sistemului cu nmol activ este asigurat de instalaia de aerare generat de sistemul de
aerare cu turbine
2 x22 KW / se menioneaz eficienta slaba a acestetui sistem de
aerare ) . Apa menajera nmolul activ din spaiul bazinului de aerare ajunge prin sistemul
de distribuie central in decantorul secundar , in care sunt reinute particulele foarte fine ce
a ce duce la reducerea particulelor in suspensie , In spaiul de aerare se introduce oxigenul
necesar desfasurarii proceselor biochimice pe o durata de 2-3 ore , in timp care se
realizeaz omogenizarea apei uzate, aerului cat si a nmolului activat, - proces in care are
loc reducerea substanelor organice biodegradabile si a amoniacului. Nmolul in exces
stabilizat aerob se depoziteaz in concentratorul de nmol unde se compacta gravitaional
Nmolul depus de la decantoare este scos prin sifonare prin 4 conducte in 4 cmine si din
acestea prin gravitaie este introdus intr-un bazin de depozitare.
Din depozit nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a zonei SC
Metalurgica SA ( iniial ) , sau vidanjat periodic
Evacuarea apelor uzate se realizeaz n prul Homorodul Mic.
Componente constructive
Treapta mecanica:
Grtare rare
debitmetru Parshall;
Treapta biologica:
bazine de aerare cuplat cu decantor secundar;
Concentrator de nmol;
Sistem de aerare cu turbine ( 2 x22 KW );
Staie pompare pentru nmol stabilizat;
Conducte si canale de incinta.
Anexe
Laborator chimic pt analize;
Vestiar , grup sanitar;
Atelier mecanic ,electric.
Ape uzate tratabile cu ajutorul staiei de epurare sunt:
ape uzate fecaloid, menajere
Apele uzate menajere, provenite din apele folosite la splat si la alte activitati din
gospodarii, care conin in general spume, grsimi ,particule minerale fine si unele particule
organice si care sunt colectate prin obiecte sanitare obinuite (chiuvete, spltoare,
sifoane de pardoseala etc.)
Debite caracteristice influente.
Debite caracteristice a apelor uzate colectate ce urmeaz a fi epurate reale
Q zi med = 638,6 mc/zi = 7,39 l/sec
Q zi max =734,4 mc/zi = 8,50 l/sec
Q or.max = 61,20 mc/h = 17,00 l/sec
Q or.min

= 6,39 mc/h = 1, 77 l/sec


Tabel nr. 7
41

TOTAL PROIECT SRL


ODORHEIU SECUIESC

Specificaie
1
Ora Vlahita
TOTAL

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Q zi med
mc/zi
l/sec
2
3
638,6
7,39
638,6
7,39

Q zi max
mc/zi
l/sec
4
5
734,4
8,50
734,4
8,50

Q or.max
mc/h
l/sec
6
7
61,20
17,00
61,20
17,00

ORIGINAL
Pagina 1

Q or.min
mc/h
l/sec
8
9
6,39
1,77
6,39
1,77

Incarcarea apelor uzate influente


Apele uzate urbane influente n staia de epurare a oraului Vlhia se compune
din ape uzate menajere i ape uzate industriale.
ncrcrile apelor uzate influente in staie de epurare conform analizelor furnizate de
operatorul staiei de epurare sunt urmtoarele:
pH

6,5-8,5

suspensii max .

300 mg/l

CBO5 max .

100 mg/l

CCO Cr

250 mg/l

azot amoniacal

10

fosfor total

2,0 mgl

detergeni sintetic biodegradabili

mg/l

5,0 mg/l

Parametrii de evacuare stabilii prin NTPA 001 /2005 si NTPA 0011


Dup epurare apele uzate sunt evacuate n prul Homorodul Mic parametrii de emisie
trebuie sa se ncadreze n valorile maxime stabilitate prin NTPA 001/2005 si NTPA 011 care
impune urmtoarele incarcari maxime
pH

6,5-8,5

suspensii max .
CBO5 max .
CCO Cr
substane extractibile n eter de petrol

60 mg/l

120 mg/l

25 mg/l

150 mg/l

125 mg/l

250 mg/l

20 mg/l

azot amoniacal

3,0 mg/l

fosfor total

2,0 mg/l

detergeni sintetic biodegradabili

Aviz Ga 274 /2012

20 mg/l
30 mg/l ( azot total )

1,0 mg/l

clor rezidual liber

0,2 mg/l

temperatura

max. 40 C

Grade de epurare necesar


pt. suspensii : ds= Cuz-Cuz (adm)/Cuz x 100 = (300-60/300)x100

= 80,00 %

pt. CBO5

: dx= Xuz-Xuzadm/Xuz x 100

= (100-25/100)x100 = 75,00 %

pt CCO cr

: dy= yuz-yuz adm /yuz x 100

= ( 250-125 /100 ) = 50,00 %

Pentru atingerea valorilor impuse de NTPA 001/2005 si NTPA 0011/2005 este necesara
realizarea in cadrul procesului de epurare a urmtoarelor grade de epurare:
80 % pentru materii in suspensie.
75 % pentru consumul biochimic de oxigen
50 % pentru consumul chimic de oxigen ( CCO cr )
70 % pentru azot amoniacal
60 % pentru fosfor total
42

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Pentru
atinge asemenea performante este necesar epurare mecano-biologica cu
denitrificare apelor uzate , nsa prezenta instalaie nu o poate realiza.
Gradul de epurare realizat
Din tabel anexa A , care prezint concentraii medii anuale a parametrilor influente si
efluente in staie de epurare pentru anul 2011, rezulta urmtoarele randamente de
reducere a noxelor in staia de epurare :
d CBO5
d CCO Cr

cca. 21 %
cca. 19 %

d susp.- nu sunt date


PH se ncadreaz in valori legale
Debit anual orar 16,51 l/s.
Disfuncionaliti existente la staia de epurare
Lipsa unor obiecte componente sau operaii de baza in vederea funcionarii normale a
staiei pentru obinerea unor randamente corespunztoare ca:
grtar fin sau decantorul primar;
deznisipator;
faza de denitrificare
separator de grsimi;
instalaie de dezinfectare pentru ape uzate epurate;
gospodria de nmol.
Capacitate redusa a staiei de epurare , chiar pt faza actuala nelund in calcul perspectiva
de fi legat la canalizare si partea nordica localitii.
Totodat trebuie arat ca:
Nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial in proiect duce la
poluarea solului si a subsolului.
In prezent nmolul nu este evacuat din cauza defectrii sistemului de si transportat si este
necesar vidanjarea acestuia. Este necesar ca aceasta faza, operaie sa fie executat conform
reglementarilor legale.
ncrcrile mari ale parametrilor de evacuare in unele perioade, datorita neevacurii
periodice a concentratorului de nmol din staia de pompare.
Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare , si ocazional realizate Goscom
Miercurea Ciuc . Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente si efluente in staie de epurare.
4.1.2.4 DOTARI
DESCRIEREA COMPONENTELOR STATIEI DE EPURARE
Bazinul de aerare i decantare:
Este o construcie din beton armat cu dimensiunile n plan de 17 x 16,60 m i adncime de
3,55 m. Bazinul este prevzut cu jgheaburi marginale i unul central. Prin jgheabul central
cu seciunea de 0,40 x 1,30 m se face intrarea apei menajere brute, uzate, de unde prin 2
vane de Dn 300 mm, de perete, intr n bazin pentru aerare i decantare.
Apele uzate provin din canalizarea S.C. Metalurgica S.A. i din sistemul de canalizare a
oraului.
43

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Pentru aerarea i decantarea apelor uzate n bazin au fost montate 2 turbine la nivelul
paralelei de stlp din beton armat. Ele au sarcina de a mprtia uniform suspensiile care se
depun pe fundul bazinului. Turbinele sunt acionate cu motor electric de 22 kW, cu turaie
de 750 rot/min.
Apa decantat iese din bazin prin cele 2 jgheaburi marginale i sunt duse apoi spre emisar .
Nmolul depus prin decantare este scos prin sifoane, prin cte 4 conducte (n dou pri) cu
Dn 100 mm, n cte 4 cmine i din acestea prin gravitaie este introdus ntr-un bazin cu
perei i radieri din beton armat n subsolul corpului de exploatare. Conductele de legtur
ntre cmine i bazinul de depozitare sunt cu Dn 200 mm.
Pentru pomparea nmolului la halda de zgur a uzinei S.C. Metalurgica S.A. s-a prevzut o
pomp tip ACV 80.
Actualmente conducta de evacuare nmol este defect, dar pentru economisire a energiei
electrice se caut soluii pentru un nou amplasament a patului de nmol.
Pentru accesul la cele 2 rotoare bazinul este prevzut cu pasarela de acces i cu parapei
metalice pe margine cu scopul evitrii cderii personalului de deservire n bazin.
Interiorul bazinului este prevzut cu perei i cane de linitire.
Pereii sunt fcute din beton armat, cu grosime de 15 cm.
Pentru rigidizarea n plan a bazinului s-au prevzut grinzi de legtur rezemate pe stlpi de
susinere a pereilor despritori i cane de linitire.
innd seama de natura terenului de fundare i avnd n vedere ca apa subteran se
gsete la mare adncime, stlpii de susinere din interior a pereilor i pasarelei rezem pe
fundaii izolate, evitnd astfel radierul general.
Bazinul este alctuit din plci mari turnate n grosime de 10 cm din beton B 200 i armate
cu reea 0 6 x 15 cm. Resturile dintre plci se colmateaz cu mastic bituminos. ntregul
bazin se fundeaz pe un teren stncos din roci semidure i dure, fr ape subterane.
Accesul n interiorul bazinului s-a prevzut pe scri metalice incastrate n perei de capt.
Pentru protecia personalului de deservire n timpul exploatrii pasarelele de acces la
turbine sunt prevzute cu balustrade metalice din eav.
Corpul de exploatare cu staia de pompare nmol stabilizat:
Corpul de exploatare deservete tehnologic staia de epurare.
Aceasta este o cldire cu parter i subsol parial pentru bazinul de nmol stabilizat, provenit
de la bazinul de aerare i decantare, nu functioneaza.
Parterul cuprinde urmtoarele ncperi:
laborator cu dimensiuni 7,00 x 4,00 m, cu pardoseala din PVC;
staia de pompare cu o pomp tip A VC, cu pardoseal de ciment rolat;
grup sanitar, format din vestibul, WC i un du, toate cu pardoseal mozaic.
nclzirea construciei se realizeaz cu sobe cu combustibil solid (lemne). Iluminatul este
natural, cu ferestre din lemn vopsite i artificial cu becuri de 60 - 100 W. Grupul sanitar este
prevzut i cu ventilaie artificial.
Accesul n staia de pompare se face direct prin ua metalic de 1,50 x 2,10 m n dou
canale.
Accesul n laborator se face indirect prin vestibul, printr-o u de lemn, cu dimensiuni de
0,90 x 2,10 m.
Construcia corpului de exploatare este amplasat lng bazinul de aerare i decantare la o
distan de cca. 7 m.
44

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Acoperiul este alctuit din plac de beton armat n terasa cu panta de 2,5-3%.
Evacuarea apelor pluviale se realizeaz prin jgheaburi din tabl zincat i barbacane.
Subsolul are o adncime impus tehnologic la cca. - 5,60 m fa de nivelul 0,00 comparat
cu cota 796,10.
Pereii subsolului i radierul sunt din beton armat, tip B 150.
Debitmetru Parshall:
Const dintr-un canal din beton i un cmin de capt. Seciunea canalului la interior este de
58 x 106 cm i seciunea cminului de 1,00 x 1,00 m. Lungimea canalului este de 11 m.
Construcia debitmetrului servete la msurarea debitului.
Pe traseul canalului s-a prevzut o strangulare din beton cu agregat cu marca B 100.
Limea canalului se reduce prin strangulare la 23 cm. Pentru accesul n interior cminului
de control s-au prevzut trepte din oel beton, la 30 cm distan pe vertical.
Grtar pentru reinerea materialelor plutitoare:
Este o construcie din beton armat. Lungimea grtarului este de 6,50 m i n seciune
transversal este de forma dreptunghiular. n interior seciunea grtarului este mprit n
dou printr-un perete despritor n grosime de 30 cm.
Pentru reinerea materialelor plutitoare s-a prevzut un grtar metalic care este montat ntrun ghidaj U de 80 mm. nclinarea grtarului este 60 fa de orizontal.
Pentru curirea grtarului, nainte i dup grtar, sunt stvilare montate n ghidaje U de
100 mm pentru posibilitatea de nchidere a apei la grtar. Manevrarea stavilelor se face de
pe pasarelele din beton armat cu o lime de 70 cm.
Debitul maxim orar a staiei de epurare este Ou zi or = 16,5 l/s,
Staia de pompare ape menajere:
Este situat pe partea sudic a oraului, lng drumul principal Vlhia-lueta, n punctul cel
mai aval de pe lng spitalul orenesc, de unde vor trebui pompate apele uzate spre staia
de epurare.
Aceast staie primete apele menajere de la fosta maternitate a localitii i le pompeaz
spre staia de epurare n bazinul de aerare i decantare.
Funcional, construcia staiei are parter i subsol.
Subsolul este un bazin care primete apele menajere. Are perei radiali din beton armat.
Forma n plan a construciei este circular cu diametru interior de 4 m.
Intrarea n staie s-a prevzut pe o u metalic, dimensiuni de 1,50 x 2,10 m.
Tehnologic staia a fost prevzut cu 2 electropompe tip ACV 80 - D., nu funcioneaz
n planeul de la cota 0,00 pe amplasamentul pompelor s-a prevzut: 2 goluri de 50 x 50
cm pentru coloanele de susinere a sorburilor, un gol de acces 80 x 80 cm pentru subsol i
2 goluri 0 = 200 mm pentru ventilaie. Golul de acces se acoper cu capac metalic 900 x
900 mm tip IPACH pentru interior. Planeul peste parter este din beton armat. Iluminarea se
realizeaz prin 5 ferestre de 0,60 x 0,80 m.
Ventilarea subsolului i parterului s-a realizat cu burlane de ventilaie Dn 200 mm, care
strpung ambele planee.
Pentru ridicarea electropompelor, n grinda planeului din tavan s-au prevzut 2 crlige
axate n dreptul agregatelor.
Cldiri terenuri - Indici de plan general .

45

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Suprafaa totala a terenului este de


Local Vlahita
Construcii totale
o

ORIGINAL
Pagina 1

: 2578,62 mp si este in proprietatea Consiliului

386,00 mp din care:


cldire administrativa
72,94 mp

magazie 1

19,64 mp

magazie 2

1,68 mp

instalaia epurare

Drumuri si platforme

291,74 mp

2182,94 mp

Spatii verzi

9,68 mp

Funcional cldirea administrativa este compusa din:


laborator

S = 28,0 mp

grup sanitar

S = 16,0 mp

staie pompare

S = 16,0 mp

4.1.2.5 BILANUL DE MATERIALE


Cantitatea materialului reinut conform gradelor epurare necesar
Debite de canalizare, ncrcri in poluani si condiii de descrcare in emisar. Alte
date sunt in GA
Q

uz zi max

= 734,4 mc/zi = 8,50 l/s

uz orar max

= 61,20 mc/h = 17,0 l/s

Incarcarile in poluanti luate in considerare:


suspensii

300 mg/l

CBO5

100 mg/l

Gradul de epurare necesar :


suspensii

80,0%

CBO5

75,0%

Cantitatea de s.u. ce intra in staia de epurare:


suspensii
CBO5

190,80 kg/zi
63,86 kg/zi

Cantitatea de s.u. retinute in:


grtar: suspensii e= 10-15 %
bazin aerare-decantare: trebuie asigurat
parametrilor de emisie.

randamente mari pt asigurarea respectrii

Cantitatea s.u influenta in Homorodul Mic - max admis prin NTPA 001/2002
suspensii
CBO5

38,31 kg/zi
15,96 kg/zi

concentraie
concentraie

de < 60 mg/l admis


de < 25 mg/l admis

4.1.2.6 MATERII PRIME SI MATERIALE

FOLOSITE

piese metalice pt reparaii cca. 1 to/an

46

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

oxigen , carbid pt sudri


ulei si vaseline de ungere cca .200 kg/an
chimicale pt laborator de analize
Mijloace de transport.
Unitatea dispune de urmtoarele mijloace de transport:
1 buc vidanjor.
4.1.2.7 UTILITATI
Alimentarea cu apa:
Apa potabila pt consumul igienico sanitar si duuri , se asigura din reeaua orenesc printro conducta de 1
Consumul maxim de apa potabila este de Q zi med = 0,360 mc/zi
Apa potabila se folosete pentru:
consum igienico- sanitar
consum tehnologic spalari igenizari.
scopuri P.S.I.
Necesarul de apa - determinat conform STAS 1343/0- 89,STAS 1343/1-91 si STAS 147890, conform breviarului de calcul .
N2zi med= 0,360 mc/zi = 0,004 l/s
N2zi max= 0,424 mc/zi = 0,005 l/s
N2 or max= 0,035 mc/h

= 0,009 l/s

Consumul efectiv anual de apa potabila : 135 mc/an = 110 mc/luna


Evacuarea apelor uzate menajere: in staie de epurare
Emisarul apelor meteorice: prul Homorodul Mic.
4.2 MATERIALE DE CONSTRUCII

Materiale de construcii utilizate la realizarea construciilor existente: crmizi, lemne, igle,


mortare i betoane de ciment, metale, plci ondulate din azbociment.
Plcile ondulate de azbociment sunt utilizate ca acoperiuri la construcii dup cum
urmeaz: o parte din construciile existente pe amplasamentul studiat ( Statie tratare,
acoperind o suprafa de 230 mp. constituind o surs de poluare a aerului cu pulberi fine
de azbest.
Fibrele de azbest avnd caracteristicile: lungimea fibrei Lf < 5 m i diametrul fibrei Df <
3m, fac parte din categoria substanelor cancerigene conform prevederilor anexei nr.1 al
Ordinului M.A.P.P.M. nr. 462/1993.
4.3

STOCAREA DE MATERIALELOR DEPOZITE DE MATERII


PRIME, REZERVOARE SUBTERANE

Materiile prime nu este cazul.


Materiale auxiliare: la statia de tratare, varul , clorul.
47

TOTAL PROIECT SRL


ODORHEIU SECUIESC

4.3.1

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

REZERVOARE SUBTERANE AFLATE N ZON

Nu sunt.
CARBURANI
Nu este cazul.
COMBUSTIBILUL
Combustibilul este lemnul de foc.
Nu sunt centrale termice de capacitare mare.
4.4 EMISII IN ATMOSFER,

EMISII DE PROCESE TEHNOLOGICE,


ALTE EMISII IN ATMOSFER

4.4.1

LA OBIECTUL ALIMENTARE CU APA

Poluani evacuai in aer.


Sursele de emisie a poluanilor n atmosfer n urma activitii desfurate sunt:
emisii dirijate de la sistemul de nclzire punct termic termica
emisii de clor gazos in cazuri nefuncionrii corecte a staiei de clorinare , sau accidente
tehnice
Evaluarea emisiilor de substane poluante la sursele fixe enumerate mai sus s-a realizat:
pe baza factorilor specifici de emisie recomandai de documentaia A.P. 42 Factori de
emisie elaborat de EPA;
prin calculul estimativ al debitelor masice (pe baza factorilor de emisie) i al concentraiilor
de poluani ( pe baza debitelor masice calculai i al debitului de efluent evacuat la surs);
prin raportarea valorilor concentraiilor calculate la limit stabilit prin reglementrile de
mediu n vigoare: Ordin nr. 462/1993 al MAPPM i Ordin nr. 756/1997 al MAPPM.cat si Legea
nr 104/2011 privind protectia atmosferei, STAS 12574/1987.
Emisii de la sistemul de nclzire.
ncperile din compartiment administrativ sunt nclzite cu energie termic furnizat de
cazan de incalzire, folosind combustibil, lemne de foc.
Surse si poluani pentru aer: gazele de ardere rezultate de la cazan, funcionnd cu lemne
de foc. Consumul de lemne de foc in timpul friguros fiind de maxim; 30 kg/h.
Parametrii arderii:
Tabel nr 8
Specificaie
U/M
Cantitatea de combstibil folosit
- volumul total de gaze arse
regim maxim
- volumul gazelor arse la virf de cos
regim maxim
- debitul volumetric gaze arse
- viteza gazelor la ieire din cos
- inaltimea coului de dispersie
- diametru la vrf de cos (De )

Valori
kg
mcN
mc
mc/s
m/s
m
m

Observaii .
30
225
321

in
in

0,10
1,80
0,5
0,35

Emisii de poluani de la cazanul de incalzire:

48

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Tabel nr 9
Poluant
Ord 462/93
Observaii.
1
5
- pulberi
100
- oxizi de sulf
2000
- oxizi de azot
500
- oxid de carbon
204

g/h

g/s

mg/Nmc

63
0,99
22,5

0,017

274

0,0003

4,84

0,006
0,056

98,4
888

250

Din tabelele de mai sus se constata ca valorile emisiilor de pulberi in suspensie si CO,
calculate conform metodologiei AP-42 va prezenta o depire uoara
fata de valorile
maxime conform Ordin 462/1993.In cazul depirii emisiilor fata de cele stabilite prin
Ordinul sus menionat se recalculeaz inaltimea coului de dispersie, daca valoarea
raportului Q/S > 5, in care;
Q debitul maxim al poluantului emis in g/h,
S parametru ce reprezint valoarea limita pe scurta durata a emisiilor de poluani in
atmosfera in g/mc si valorile pentru diferii poluani sunt stabilite de ordinul sus
amintit.
Valorile raportului Q/s:
pulberi

63 /500

oxizi de azot

= 0,126

22,5 /300 = 0,034

oxid de carbon

204/6000 = 0,18

Deoarece valoarea raportului Q/s este mai mic dect 5, nu este necesar calcule de
verificare a nlimii coului de dispersie. si corespunde , in conformitate cu Ordinul MAPPM
nr. 462/1993. )
Valorile

imisiilor de noxe de la cazanul de nclzire

( Conf. anexa 1 )

Tabel nr. 10
Denumire poluant
(m/s)
Sezon rece ( maxim)
- pulberi
2,1
- oxizi de azot
2,1
- oxid de carbon
2,1

Concentr.

Distanta

st. atm.
(micrg/mc)

V vint

Observaii
(m)

11,90

85

S.

4,30

85

39,00

85

Calculul concentraiilor de poluani pentru perioada de mediere de 60 min calculat pentru


varianta sezon rece in condiii meteorologice diferite (stabilitatea atmosferei de la foarte
instabil la foarte stabil, respectiv viteza vntului) pentru care sa calculat concentraiile
noxelor la distante de la 35 m la 335 m pe direcia vntului, pun in evidenta urmtoarele
valori maxime, in cazul sistemelor de ardere ( anexa )
In condiii de sezon rece:
49

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

C part. in susp.

= 11,90

g/mc

C oxizi de azot

= 4,36

g/mc

C oxid de carbon = 39,00

ORIGINAL
Pagina 1

g/mc

Concentraia maxima a poluanilor se atinge la o distanta de 60 m de sursa intr-o atmosfera


stabila la viteza vntului de 2,1 m/s.
innd cont de faptul ca debitul masic al poluanilor emii de instalaiile de ardere este
redus ,concentraiile noxelor mult mai mici dect valorile maxime admise prin Ordinul
462/93 instalaia nu constituie un factor de poluare in zona. Din cele de mai sus rezulta ca
valoarea concentraiei la nivel de imisie ( timp de mediere 30 min ) in cazul poluanilor
studiate sunt mult sub valorile admise prin STAS 12.574/87, in cazul cel mai defavorabil
rezulta ca obiectivul nu reprezint o sursa de poluare pt atmosfera in zona.
Valorile CMA, la nivel de imisie, obinute sunt cu mult sub cele stabilite de STAS
12574/1987, iar Imisiile pentru poluani SOx , CO si Hidrocarburi nu sa calculat
deoarece valorile lor sunt neglijabile.
Emisii de poluani de la utilajele din dotare
Emisiile gazelor de eapament
Nu este cazul
Emisii de poluani din procesul de dezinfectare clorinare
In procesul de dezinfectarea apei se utilizeaz clorul. Clorul este un produs chimic
deosebit de periculos si toxic. La transportul, depozitare si utilizarea trebuiesc respectate
nomele specifice referitoare la acest produs.
Emisiile de clor datorita avariilor sau accidentelor de utilaje poate avea consecine deosebit
de grave.
Valoare limita de expunere profesionala pentru ageni chimici CMA la locul de munca ,
conf. Tabel nr.31din Norme Generale de Protecie a muncii pt clorul gazos:
Valoare limita pt termen scurt ( 15 min ) este de 1 mg/mc
Emisii de noxe in aer - Conform Ordin 462/1993 , cap 6.1 pt clor:
Valoarea limita de emisie 5 mg/mc , la un debit

masic de < 50 g/h

Concentraia la nivel de imisii, pt timp de mediere 30 min este de 0,1 mg/mc conform
STAS 12574/1987 4.4.2

LA OBIECTUL CANALIZARE SI STATIE DE EPURARE

Poluanti evacuai in aer


Principalele sursele de emisie a poluanilor n atmosfer n urma activitii desfurate sunt:
Sursele de emisie de pe amplasament se caracterizeaz prin :
emisii dirijate (sisteme de nclzire );
emisii discontinue joase (pat de uscare a nmolului, vidanjor);
emisii joase liniare (mijloace de transport).
Evaluarea emisiilor de substane poluante la sursele fixe enumerate mai sus s-a realizat
prin:;
pe baza factorilor specifici de emisie recomandai de documentaia A.P. 42 Factori de

50

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

emisie elaborat de EPA;


prin calculul estimativ al debitelor masice (pe baza factorilor de emisie ) i al concentraiilor
de poluani ( pe baza debitelor masice calculai i al debitului de efluent evacuat la surs);
prin raportarea valorilor concentraiilor calculate la limit stabilit prin reglementrile de
mediu n vigoare: Ordin nr. 462/1993 al MAPPM i Ordin nr. 756/1997 al MAPPM.cat si
Ordinul MAPM 592/2003 si STAS 12574/1987
Emisii de la sistemul de nclzire
ncperile din birou este nclzit cu cazan de nclzire, folosind combustibil , lemne de
foc. Surse si poluani pentru aer: gazele de ardere rezultate de la cazan , funcionnd cu
lemne de foc. Consumul de lemne de foc in timpul friguros fiind de maxim ; 20 kg/h.
Noxe emise in aer de a sisteme de ardere, cu coninut de pulberi ( sedimentabili si in
suspensie, oxizi de azot, oxid de carbon , bioxid de carbon )
Poluanii evacuai n atmosfer (n mg/mc i g/s).
Parametrii

arderii

Tabel nr 11
Specificaie
1

U/M

Valori

Observaii .
2

20

5
- volumul total de gaze arse
regim maxim
- volumul gazelor arse la vrf de cos
regim maxim
- debitul volumetric gaze arse
- viteza gazelor la ieire din cos
- inaltimea coului de dispersie
- diametru la vrf de cos (De )
Emisii

de

poluani

de

mcN

152

in

mc

225

in

mc/s
m/s
m
m

0,10
1,10
7,0
0,25

la

cazanul

de

nclzire;

Tabel nr 12
Poluant
Observaii.
1
- pulberi
100
- oxizi de sulf
2000
- oxizi de azot
500
- oxid de carbon

g/h

g/s

mg/Nmc

3
42
0,66
15,1

136

0,037

Ord 462/93

0,012

5
274

0,0002

4,84

0,0041

98,4

888

250

Din tabelele de mai sus se constata ca valorile emisiilor de pulberi in suspensie si CO,
calculate conform metodologiei AP-42 va prezenta o depire uoara fata de valorile
maxime conform Ordin 462/1993.In cazul depirii emisiilor fata de cele stabilite prin
Ordinul sus menionat se recalculeaz inaltimea coului de dispersie, daca valoarea
raportului Q/S > 5, in care;
Q debitul maxim al poluantului emis in g/h
S parametru ce reprezint valoarea limita pe scurta durata a emisiilor de poluani in
atmosfera in g/mc si valorile pentru diferii poluani sunt stabilite de ordinul sus
amintit.

51

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Valorile raportului Q/s:


pulberi

63 /500

oxizi de azot

= 0,126

22,5 /300 = 0,034

oxid de carbon

204/6000 = 0,18

Deoarece valoarea raportului Q/s este mai mic dect 5, nu este necesar calcule de
verificare a nlimii coului de dispersie. si corespunde , in conformitate cu Ordinul MAPPM
nr. 462/1993. )
Valorile

imisiilor de noxe de la cazanul de nclzire

( Conf. anexa 1 )

Tabel nr. 13
Denumire poluant
Observaii

Concentr.

Distanta

st. atm.

(micrg/mc)
(m/s)
Sezon rece ( maxim)
- pulberi
2,1
- oxizi de azot
2,1
- oxizi de carbon
2,1

V vint
(m)

14,60

60

S.

5,26

60

47,95

60

Calculul concentraiilor de poluani pentru perioada de mediere de 60 min calculat pentru


varianta sezon rece in condiii meteorologice diferite (stabilitatea atmosferei de la foarte
instabil la foarte stabil, respectiv viteza vntului) pentru care sa calculat concentraiile
noxelor la distante de la 35 m la 335 m pe direcia vntului, pun in evidenta urmtoarele
valori maxime, in cazul sistemelor de ardere ( anexa )
In condiii de sezon rece :
C part. in susp.

= 14,60

g/mc

C oxizi de azot

= 5,26

g/mc

C oxid de carbon = 47,95

g/mc

Concentraia maxima a poluanilor se atinge la o distanta de 60 m de sursa intr-o atmosfera


stabila la viteza vntului de 2,1 m/s.
innd cont de faptul ca debitul masic al poluanilor emii de instalaiile de ardere este
redus ,concentraiile noxelor mult mai mici dect valorile maxime admise prin Ordinul
462/93 instalaia nu constituie un factor de poluare in zona. Din cele de mai sus rezulta ca
valoarea concentraiei la nivel de imisie ( timp de mediere 30 min ) in cazul poluanilor
studiate sunt mult sub valorile admise prin Legea nr 104/2011 ( Legea proteciei atmosferei
) si STAS 12.574/87, in cazul cel mai defavorabil rezulta ca obiectivul nu reprezint o sursa
de poluare pt atmosfera in zona.
Valorile CMA, la nivel de imisie ,obinute sunt cu mult sub cele stabilite de STAS
12574/1987, iar Imisiile pentru poluani SOx, CO si Hidrocarburi nu sa calculat
deoarece valorile lor sunt neglijabile.
Emisii de poluani de la utilajele din dotare
Emisiile gazelor de eapament sunt formate din monoxid de carbon, oxizi de azot, particule
i ali produi de combustie.
Debitele masice orare maxime ale poluanilor emii prin gazele de eapament ale
autovehiculelor care se deplaseaz n cadrul incintei ( lund cazul cel mai defavorabil cnd
n timp de o or, funcioneaz vidanjorul i utilajele de ncrcare a reziduurilor ).
52

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Emisiile gazelor de eapament sunt formate din monoxid de carbon, oxizi de azot, particule
i ali produi de combustie.
Concentraia principalelor substane poluante n gazele de eapare pentru diferite motoare
i regimuri de funcionare sunt prezentate n urmtorul tabel
Tab
el nr 14
Natura poluanilor

Conc.

0
oxid de carbon
oxizi de azot
Aldehide

1
%
%
Ppm

Mers n gol
MAS
MAC
2
3
7,00 Urme
0,50
0,04
30,00 60,00

hidrocarburi

Ppm

10,00

Accerelare
MAS
MAC
4
6
8,00
urme
0,10
0,01
600,0 250,00
0
10,00
10,00

20,00

Decelerare
MAS
MAC
7
8
2,00
Urme
1,00
0,03
20,00 30,00
200,00

30,00

Not:
MAS- motor cu aprindere prin scnteie
MAC- motor cu aprindere prin comprimare
Noxele evacuate prin gazele de eapament trebuie s se ncadreze n prevederile STAS
11369/1979 respectiv O.M.T. nr.537/1997 pentru autovehicule importate de la 1998 precum
i n prevederile Ordinului MAPPM nr. 462/1993
Valorile

limit

noxelor

din

gaze

de

eapament

Tabel nr. 15
Categoria
autovehiculelor

M 3,5 t
Transport de materiale
(Vidanjor)

Reglementarea

EURO 2

Valori limit
CO g/km
benzin Diesel

HC+NOx g/km
benzin Diesel

Particule g/km
Benzin Diesel

2,72 - 6,9

0,97 1,7

0,14 0,25

Conform Ordinul M.A.P.P.M. nr. 462/1993 anexa nr.1. valorile limit a plumbului i a
cadmiului evacuate prin gaze de eapament sub form de pulberi sunt:
cadmiu: 0,2 mg/m 3 la Qm >1 g/h;
plumb : 5 mg/m3 la Qm > 25 g/h;
Emisii de poluani din procesul de epurare
n cadrul staiei, epurare a apelor uzate se realizeaz prin metoda aerob, n aceast
situaie emisiile de noxe i mirosuri sunt neglijabile, n cazul neasigurrii funcionrii la
parametrii proiectai, pot fi evacuate n atmosfer urmtoarele poluani a cror valoare
olfactiv (VO) prezint valori ridicate:
hidrogenul sulfurat, degaj un miros de ou stricat foarte puternic;
mercaptani ( metilmercaptan, etilmercaptan) elibereaz un miros de varz stricat;
amoniacul prezint un miros neptor;
aminele ( metilamina, - prezint un miros de pete foarte pronunat;
acizi organici: acid acetic, acid butiric, acid valeric cu miros puternic i neptor;
53

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

aldehid butiric cu miros rnced;


aldehid izovaleric cu miros neplcut de mr stricat.
Valoarea olfactiv ( VO ) reprezint raportul dintre tensiunea de vapori saturai a unei
substane i concentraia limit de percepere, se utilizeaz ca unitate de msur pentru
aprecierea cantitativ a mirosului.
Procedeele de tratare a nmolurilor sunt multiple i variate, fiecare obiectiv trebuie studiat
n condiiile sale specifice, documentaia prezentat trateaz prelucrarea nmolurilor prin
procedeul de prelucrare mecanic dinamic i paturi de deshidratare.
Principala surs de poluare pentru aer de pe amplasament reprezint noxele rezultate din ;
colectarea i depozitarea n condiii necorespunztoare a reinerilor de la grtare, din
fermentarea anaerob i aerob a nmolurilor rezultate din concentratorul de nmol i
depozitat in bazinul de nmol .
Conform reglementarilor legale concentraiile maxime a noxelor in aerul zonelor protejate
nu trebuie sa se depaseasca cele prevzute prin Legea nr 104/2011 si STAS 12574/1987,
iar pentru substanele nespecificate in acest document ele sa nu prezinte mirosuri olfactive
si persistente.
ncadrare in norme legale:
Emisiile sub form de pulberi rezultate din ntreaga activitate desfurat pe amplasament
nu trebuie s depeasc 50 mg/mc la un debit masic de 0,5 kg/h, la o dimensiune a
diametrului mediu al particulelor (dp) 5 nm, n conformitate cu reglementrile legale :
Ordin MAPPM nr 462/1993 .
Mirosuri Statie de epurare . In unele perioade , inspecial vara , exista mirosuri persistente
dezagreabile datorita nefuncionrii corespunztoare a procesului de epurare de aceea
este foarte urgent necesar retehnologizarea staiei de epurare.
Concluzii privind emisiile de noxe:
Valorile emisiilor de noxe calculate au fost comparate cu valorile maxime admise
(Valori Limita de Emisie) prescrise in Ordinul MAPPM 462/1993,coroborate cu Ordinul nr.
756/1997 in vederea stabilirii pragurilor de alert:
a.) n cazul punctului termic a instalaiilor de ardere, valorile maxime stabilite:
Tabel nr.
16
Indicatori

Prag intervenie
( mg/Nmc )

Pulberi
Monoxid de carbon
Substante organice
expr in C
Oxizi de azot

100
250
50

Prag de
alerta
( mg/Nmc )
70
175
35

500

350

Mrime de referin: valorile limite se raporteaz la un coninut n oxigen al efluentului.


gazos de 6 %.
Comparnd valorile din tabele prezentate mai sus, se observa ca valorile la emisie
prevzute in Ordinul nr, 462/1993 al MAPPM, sunt respectate la parametrii: oxid de carbon,
oxizi de azot, oxizi de sulf, concentraiile acestora situndu-se sub pragul de alert, care
reprezint 70 % din pragul de intervenie (valoarea limita a emisiilor).
EMISII din zon, emisii de proces, alte emisii atmosferice
54

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Emisiile de noxe n aer din zona respectiv provin:


n prezent NU SUNT - numai din cele rezultate din circulaia de autovehiculelor in zona.
Emisiile provenite de la centrale termice industriale nvecinate
In zona studiat nu sunt uniti industriale in funciune.
4.5 ALIMENTARE CU AP EFLUENTI TEHNOLOGICI I MENAJERI,

SISTEMUL DE CANALIZARE A APELOR UZATE


4.5.1

PROTECTIA CALITATII APELOR

4.5.1.1 CAPTAREA SI TRATAREA APELOR UZATE


Sistemul de alimentare cu apa descris mai sus.
Protecia calitatii apelor.
Surse de ape uzate.
Apele uzate provin de la:
Instalaiile sanitare, din consum igienico sanitar, din spalari si igienizri a ncperilor.
Instalatii tehnologice de splarea filtrelor de nisip
Apele uzate menajere:
Cantitatea apelor uzate menajere pe baza breviarului de calcul anexat:
Qs zi med = 0,640 mc/zi =0,012 l/s
Qs zi max = 1,30 mc/zi =0,015 l/s
Qs or max = 0,18 mc/zi =0,050 l/s
Apele uzate sunt epurate in fosa septica tricompartimentala cu dimensiuni de
4,80 x 2,40 x 2,55 = 29,37 mc
Dupa epurare apele uzate sunt evacuate in pariul Varghis.
Nmolul depus in fosa septica se evacueaz periodic, din primele camere, prin vidanjare, si
se poate folosii ca fertilizant al solului pe terenurile inpadurite.
Apele uzate tehnologice
Apele uzate tehnologice rezultate din procesul de splarea filtrelor de nisip operaie ce se
executa zilnic, si depinde de calitatea apei captate, debitele fiind mai mari in anotimpul
ploios, cnd coninutul de suspensii in apa bruta este mai mare- implicit necesita splri
mai intense.
Debitul apelor uzate evacuate
Qs zi med = 120,0 mc/zi = 1,28 l/s
Apele uzate de splare sunt evacuate in prul Vrghis.
Concentraia
maxima a poluanilor din apele evacuate in ape de suprafaa conf
NTPA001/2002
suspensii
CBO5
pH

60 mg/mc
25 mg/mc
6,5-8,5

55

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Apele pluviale de pe construcii si terenurile din incinta sunt evacuate prin


colectoare interioare in santul marginal unitatii in prul Vrghi
Debitele apelor pluviale sunt:
Qv = 9 l/s, Qc = 7 l/s.
4.5.1.2 CANALIZAREA SI STAIA DE EPURARE
Protecia calitatii apelor.
Sursele de ape uzate si compuii acestor ape .
Sursele de poluant evacuat in ape de suprafaa reprezint apele uzate epurate evacuat din
staia de epurare studiata.
Debilele apelor uzate evacuate , conform tabelului nr I/1 cat si din graficele anexei 1/1
rezulta ca debitul apelor care este evacuat in prul Homorodul Mic este cuprins intre
14,5- 17 l/sc

Debite caracteristice fiind:


Tabel nr 17
Specificatie
1
Oras Vlahita
TOTAL

Q zi max
mc/zi
l/sec
2
3
734,4
8,50
734,4
8,50

Q zi med
mc/zi
4
638,6
638,6

l/sec
5
7,39
7,39

Q or.max
mc/h
6
61,20
61,20

l/sec
7
17,00
17,00

Q or.min
mc/h
8
6,39
6,39

l/sec
9
1,77
1,77

Incarcarea apelor uzate evacuate trebuie sa se ncadreze in valorile admise prin legea
188/2002, cu complectrile ulterioare, respectiv normativ NTPA 001 si NTPA011 care
impune realizarea gradelor de epurare prezentat in capitolul II, astfel ca sa fie asigurat
respectarea ncadrrii in urmtoarele valori maxime la evacuarea apelor uzate din staia de
epurare:
pH

6,5-8,5

suspensii max.

60 mg/l

CBO5 max.

25 mg/l

CCO Cr
substane extractibile n eter de petrol

125 mg/l
20 mg/l

azot amoniacal

3,0 mg/l

fosfor total

2,0 mg/l

detergeni sintetic biodegradabili


clor rezidual liber
temperatura

1,0 mg/l
0,2 mg/l
max. 40 C

Valorile medii ale principalilor parametrii ai apelor uzate, influente si efluente din staia de
epurare pe luni din cursul anului 2011 (debit, CBO 5, CCOcr suspensii, Azot amoniacal)
furnizat de beneficiar sunt prezentate in tabelul anexat si graficul anexat.
Totodat sunt anexate buletinele de analiza privind principalii parametrii intrare- esire cu
valori momentane a parametrilor determinate executat, la solicitarea beneficiarului de
catre SC Goscom SA Miercurea.

56

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Din buletinele analiza rezulta ca staia de epurare lucreaz cu randamente sub cele
prevzute prin normativele mai sus amintite, datorita tehnologiei aplicate nvechite, a
uzurii instalaiilor, cat si nefuncionarea unor pari a instalaiilor.
Pentru a atinge performantele prescrise in normativele specificate impuse, este necesar
procedeul de epurare biologica cu faza de denitrificare a apelor uzate.
Este de menionat faptul ca staia de epurare nu a fost dotat cu instalatii de tratare a
nmolului rezultat , fiind prevzut cu sistemul de pompare pe halda de zgura a SC
Metalurgica SA , care in unele perioade nu funcioneaz.
In concluzie este necesar modernizarea staiei de epurare prin retehnologizare
reutilare ,pt a obine randamentele prescrise, respectarea parametrilor de
evacuare cat si mrirea capacitaii staiei innd cont ca o mare parte a
localitii inca nu beneficiaz de sistem de canalizare , apele uzate ajungnd pe
marginea drumurilor polund solul si subsolul.
Staiile si instalaiile de epurare, preepurare a apelor uzate, randamente de
reinere a poluanilor, locul de evacuare.
Descriere detailata a fost prezentata la capitolul II.
Poluani evacuai in mediu ( in mg/l si kg/zi )
Luind ca baza parametrii de evacuare prescrii, cantitatea
uzate epurate in paraul Homorodul Mic, la debitul de:

poluanilor emii cu apele

Debitele caracteristice a apelor uzate evacuate:


Q
Q

uz zi med

= 638,6 mc/zi = 7,39 l/s

uz orar max

= 61,20 mc/h = 17,0

Cantitatea poluanilor emii ( la parametrii prescrii )


Tabel nr 18
Nr
crt

Indicator

1
1

2
Mat in suspensie

2
3

CBO5
Total

Intrat
mg/l
3
300
100

Kg/zi
4
191,
4
63,8
255,
2

Reinut

Esit

mg/l
5
240

Kg/zi
6
131,4

mg/l
7
60

Kg/zi
8
38,31

75

47,83
179,23

25

15,96
54,27

Observa
tii
9

Aceste cantitati emii si reinui, variaz in funcie de funcionarea concreta a staiei , cat
si de concentraiile influente.
Accidente posibile la staia de epurare oreneasca:
Poluarea solului sau apelor de suprafata prin ape uzate menajere evacuate fara treapta
biologica de epurare (realizat numai prin treapta mecanica).
Neevacuarea la timp si netransportarea apelor uzate din bazinul vidanjabil, la staia de
epurare oreneasca.
Necurirea anurilor de evacuare a apelor pluviale de pe platforma.
Neurmrirea funcionarii instalaiilor tehnologice de epurare a apelor uzate.
Pentru evitarea unor astfel de incidente unitatea are obligaia de a reface instalatia de
colectare si evacuare ape uzate conform planului programului de conformare propus si va
numii persoane competente pentru urmrirea exploatrii corespunztoare a instalaiilor ap
canalizare, pe baza unui program i sarcini concrete in care intr i obligaii de executarea
analizelor prin laboratoare de specialitate a parametrilor de evacuare a diferitelor tipuri de
57

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

ape uzate, ct i funcionarea eficient a acestor instalaii.


La instalatia de tratare ape potabile: este deosebit de important urmrirea transportului,
depozitarea, utilizarea clorului in procesul de dezinfectare a apei potabile.
nscriere in prevederile autorizaiei de gospodrire a apelor
Autorizaia de gospodrire a apelor: Nr 274/31.01.2012 emis de Administraia
Naionala Apele Romane, Administraia Bazinala de apa Olt.
Din tabelul anexat privind calitatea apelor uzate evacuate in prul Homorodul Mic se
constata ocazional unele depiri la parametrii CBO5, CCO cr, azot amoniacal ( total) fata
de cele prescrise prin autorizaio GA, rezultat din tabelul nr 1 anexat documentaiei.
4.6 PRODUCEREA SI ELIMINAREA DEEURILOR

4.6.1

CAPTAREA, TRATAREA ALIMENTARE CU APA

Gestiunea deseurilor.
Din activitatea desfurat pe amplasament n timpul funcionarii obiectivului rezult
urmtoarele tipuri de deeuri, codificate conform Catalogului European al Deeurilor:
deeuri menajere i asimilabile cu cele menajere ;
nmoluri de la fosa septica;
deeu reciclabil
Deseuri menajere; deseuri menajere circa 24 mc/an - colectate in conteinere si preluate
de catre SC AVE HARGHITA SALUBRITATE Odorheiu Secuiesc.
Deseuri tehnologice reciclabile: deseuri metalice cca. 1 t/an colectate si predate la SC
Remat Harghita SA.
Nmolul depus in fosa septica se evacueaz periodic, din primele camere, prin vidanjare, si
se poate folosii ca fertilizant al solului pe terenurile mpdurite.
Gestiunea substanelor toxice si periculoase.
a. Clorul folosit in procesul de dezinfectare clorinare descris in capitolul de mai
cantitatea aflata in unitate : intre 10-500 kg.

sus

b. Reactivi chimici folosi in laboratorul chimic pt care unitate a solicitat si a obinut


Autorizaie nr 2618/04.11.2003 pt deinerea si utilizarea substanelor toxice anexat
documentaiei.
c, Aviz prealabil pentru operaiuni cu precursori categoria I. pt Permanganat de potasiu.
d. Aviz de funcionare pt operaiuni cu precursori nr . 8318/2003 pt Acidul Sulfuric.
Lista persoanelor autorizate sa lucreze cu aceste produse sunt consemnate in aprobrile de
mai sus. ( anexat docmentatiei ).
Gestiunea ambalajelor.
Nu este cazul.
4.6.2

CANALIZARE, STATIE DE EPURARE

Gestiunea deseurilor.
Din activitatea desfurat pe amplasament n timpul funcionarii obiectivului rezult
urmtoarele tipuri de deeuri, codificate conform Catalogului European al Deeurilor:
deeuri menajere i asimilabile cu cele menajere: 20 01 08;
58

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

nmoluri de la epurarea efluenilor proprii: 02 07 05;


reineri de la grtare, nisipuri, nmoluri de la epurarea apelor uzate municipale: 19 08 05.
Directiva 86/278/EC privind proecia mediului, n special a solului, atunci cnd se utilizeaz
nmoluri de epurare n agricultur, amendat de Directiva 91/692/CE i de Regulamentul
(CE) nr. 807/2003, transpus n legislaia naional prin O.M. nr. 344/ 2004 pentru aprobarea
Normelor tehnice privind protecia mediului i n special a solurilor, cnd se utilizeaz
nmolurile de epurare n agricultur.
Astfel , In cazul n care calitatea nmolului de la staia de epurare nu este pretabil folosirii
n agricultur, staia de epurare va trebui s gseasc alte modaliti de eliminare a
nmolului. Una dintre aceste posibiliti poate fi eliminarea nmolului din staii de epurare
de ape uzate menajer la depozitul de deeuri nepericuloase cu respectarea prevederilor
BAT-lui pentru depozite ( coninut de umiditate max. 65% i depunerea pe depozit
amestecat cu deeurile menajere n proporie 1:10)
Conform SR 13400, nmolurile provenite de la staiile de epurare oreneti dup treapta
de epurare biologic i fermentare, deshidratare de pe platformele de uscare sau instalaiile
mecanice de deshidratare cu o umiditate de 65%, se pot depozita numai n depozite
controlate. Oraul Vlhia nu are amenajat depozit de deeuri menajere controlate.
Nmolurile concentrate pot fi depuse prin pompare pe halda unitatii SC Metalurgica SA ,
sau vidanjate transportate pe fnei, in prezent instalatia este defecta.
Reinerile de grtar, nmolurile brute, deshidratate, trebuie ndeprtate din staia
de epurare. Nmolul poate fi depozitat n gropi, foste cariere de nisip sau n
depresiuni cu condiia s nu produc miros neplcut n apropierea depozitului sau
s nu impurifice apele subterane.
Cantitatea total de materiale rezultate din procesul de epurare:
Nmol concentrat din staia de epurare cu coninut de substana uscata cca. 165 kg/zi s.u.
cca62 to/an
Substane solide reinute pe grtare cca. 25 kg/zi 9 to/an colectat in conteiner si depuse
la halda de deseuri locale.
Alte tipuri de deseuri rezultate din activitate
Deseuri tehnologice reciclabile:
deseuri metalice cca. 1 t/an colectate si predate la SC Remat Harghita SA
Deseuri menajere
deseuri menajere circa 12 mc/an - colectate in conteinere si depuse pe halda comunala
Gestiunea substanelor toxice si periculoase.
n cadrul unitii nu se utilizeaz substane toxice i periculoase.
Gestiunea ambalajelor.
Nu este cazul.
4.7 ALIMENTARE

CU ENERGIE
ENERGIEI TERMICE

ELECTRICA

SI

ASIGURAREA

Asigurarea energiei electrice


Energia electrica se asigura din sistemul naional, prin transformatorul de 250 KVar instalat
in unitate. Intretinerea ,schimbarea uleiului este realizat de SC Electrica SA pe baza de
contract.
Asigurarea energiei termice

59

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Energia termica pt sezonul rece se asigura cu cazanul de nclzire, consumul maxim de


lemn de foc pt nclzire este de cca. 30 kg/h. Elementele coului de dispersie H = 9,5 m De
= 0,35 m.
Canalizare staie de epurare
Asigurarea energiei electrice
Energia electrica se asigura din reeaua stradala.
Asigurarea energiei termice.
Energia termica pt sezonul rece se asigura cu soba de nclzire, consumul maxim de lemn
pt nclzire este de cca. 20 kg/h. Elementele coului de dispersie H = 7,0 m D = 0,25 m.
4.8 PROTECIA MUNCII SI IGIENA LOCULUI DE MUNC

Organizarea activitii de protecie a muncii este in concordan cu prevederile Legii


Proteciei Muncii, avnd in vedere aspecte legate de igiena si protecia muncii astfel este
de menionat:
starea de curenie si ordine din unitate: la staia de tratare ape potabile este curenie
sunt corespunztoare, si ordine, sunt instituite zone de protectie sanitara att la captri cat
si la staia de tratare conform reglementarilor legale
Staia de tratare este ngrdit cu o singura poarta de intrare care este nchis cu lact. Intra
numai persoane autorizate . Paza obiectivului este asigurat in permanenta
modul de circulaie in incinta obiectivului: Sunt mari suprafee
parcri si circulaie nestingherit a autovehiculelor;

parial betonate pentru

Lucrtorii sunt instruii in vedere respectrii normelor de protectia muncii si de sntate.


Dozarea clorului in apa potabila se realizeaz in staia de clorinare sub controlul si
supravegherea operatorului principal al staiei
Este necesar a se verifica in permanenta aceasta operaie cat si depozitarea clorului gazos.
Clorul este un gaz toxic periculos, depozitarea si manevrarea cisternei de 500 kg in care
se aprovizioneaz trebuie manevrat cu deosebita grija , respectand normele de protectie a
muncii
Este necesar verificare periodica a dotrilor de protectia muncii, mnui, ochelari de
protectia existenta mtii de gaze pt clorul gazos.
Echipa de prima intervenie trebuie sa fie instruit
La staia de epurare se va verifica periodic , starea balustradelor , aprtorilor pt a
mpiedica cderea in bazinul staiei de epurare. Se va respecta normele de protectie a
muncii la motoare electrice , turbine de aerare, dispozitivele de colectare a plutitoarelor
In laborator se va da o atenie deosebita pstrrii si folosirii reactivilor. Permanganatul de
potasiu cat si Acidul sulfuric se va utiliza numai conform reglementarilor in baza aprobrii
organelor de drept.
starea utilajelor si instalaiilor in raport cu riscul accidentelor : la staie de epurare Este
necesar ca in scurt timp unitatea s fie dotat att cu noi instalaii si utilaje tehnologice
performante ct si instalaii de msurare in vederea epurrii apelor conform cele prescrise
de NTPA 001/2005 cat si evacuarea nmolului conform celor prescrise in autorizaie GA
existena planului de aciune in caz de dezastre si accidente: Nu este.

60

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

4.9 PREVENIREA SI STINGEREA INCENDIILOR

Ansamblul msurilor de prevenire si stingerea incendiilor:


Unitatea insasi prin destinaia sa nu este vulnerabil la incendii, nici staia de tratare, nici
staia de epurare nu prezinte pericol de incendii.
Nu dispune de staii de alimentare cu carburani.
Combustibilul folosit este lemnul de foc ca este stivuit in curtea unitatilor.
Se va avea grija de curatirea temporara a courilor, cat si supravegherea slilor
instalaiilor de ardere unde sa nu fie depozitate alte produse inflamabile.
Instalatia electrica se va verifica periodic.
Se va avea grija ca tot timpul sa fie asigurat rezerva de apa de incendiu pt oraul Vlhia
.rezerva de ap pentru stins incendii de 2x250 mc.
Totodata se va avea grija pt a asigura
stingtoare de incendii cu spum chimic si praf.
responsabil cu probleme PSI, din partea conducerii unitii.
marcarea ieirilor de incendiu
asigurarea accesului in zon cu mijloace speciale pentru stingerea incendiilor
Pregtirea personalului pentru astfel de incendii.
Modul de verificare si de ntreinere a mijloacelor de intervenie
4.10

ZGOMOTUL I VIBRAIILE

Protecia mpotriva zgomotului si vibraiilor.


Surse de zgomot
Unitatea nu este dotata cu utilaje sau instalatii, care sa genereze zgomot. Att in exteriorul,
cat si in halele de fabricaie nivelul de zgomot este mult sub valorile maxime admise.
Conform Ordinului Ministerului Sanatatii nr. 536/1997 limitele de zgomot admise pentru
zonele din vecintatea ntreprinderilor sunt dupa cum urmeaz ;
ziua intre orele

6 - 22 : curba Cz 45 sau valoarea globala 50 dB(A)

noaptea intre orele

22 - 6 : curba Cz 55 sau valoarea globala 40 dB(A)

In conformitate cu discuiile cu autoritile locale, rezult c pn n prezent nu au aprut


reclamaii legate de activitile din zon sau din mprejurimi.
4.11

SECURITATEA ZONEI

Perimetrul unitii este parial mprejmuit cu gard de sarma. Intrarea se face printro
poarta unde este paza permanent timp de 24 ore si o poarta deschis temporar .Statia de
tratare fiind considederat zona de protectie sanitara.
Toat curtea interioar pe timp de ntuneric este iluminat corespunztor.n conformitate cu
investigaiile efectuate, din declaraiile angajailor din zon rezult c nu s-au nregistrat n
ultimii ani cazuri de hoie sau vandalism.
Alarmarea personalului se face cu ajutorul telefonului.

61

TOTAL PROIECT SRL


ODORHEIU SECUIESC

4.12

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

PROXIMITATEA CABLURILOR ELECTRICE

Aa cum rezult din schema general, cabluri de nalt tensiune nu traverseaz unitatea,
staia de transformatoare aflndu-se la limita incintei - staie frafo prezentat mai sus.
4.13

SURSE DE INFORMARE

Conducerea unitii
Angajaii unitii
Secii de producie
Documentare in secii de producie si servicii de specialitate
Consiliul Local Vlhia
5. CALITATEA SOLULUI
5.1 EFECTE

POTENIALE
ALE
AMPLASAMENTUL ANALIZAT

ACTIVITII

DE

PE

Efecte poteniale ale activitii de pe amplasamentul analizat.


Starea mediului in zona oraului Vlhia
( in baza datelor publicate de Inspectoratul de Protecia Mediului Harghita
privind starea mediului in judeul Harghita ).
a.

prin raport

Calitatea apelor de suprafaa.

Conform datelor furnizate de Direcia Apelor, evaluarea calitatii rurilor si praielor, bazat
pe valorile caracteristice medii ale msurtorilor din anul 2010.
Dintre afluenii Oltului, pe prul Homorodul Mic in aval de oraul Vlhia,
calitatea apei sa incadrat in limitele clasei II att la grupa indicatori Regimul oxigenului
cat si la grupa Nutetrienti
ncadrarea seciunilor de supraveghere in categorii de calitate( in baza de msurtori )

Cursul de apa

Seciunea

Homorodul Mic

Aval Vlhia

Vrghi

*RO regim de oxigenare ,GM grad de mineralizare ,TS toxice si speciale ,TI toi
indicatorii

Ordinul

Amonte Vlhia

II
II

Categoria de calit dpv fizico chimic


Ro I,
RO I

GM I
GM I

TS D
TS -

Monitorizarea prizei de apa de suprafata folosita pentru potabilizare se prezint


astfel :
Parau Vrghi amonte de captare; s-a incadrat in categoria A3, de calitate ( tr I 2010 a fost
incadrat la categoria A 2 ) determinat de grupa indicatorilor bacteriologici, ( coliformi total,
coliformi fecali )
Starea apelor subterane: Rezultatele analizelor efectuate de IPM Miercurea Ciuc semnaleaz
poluarea apei freatice in preajma hlzilor de deeuri industriale (Minele Lueta) cu fier,
mangan, plumb.
b.

Calitatea aerului

Nu sa constat o poluare semnificativa cu pulberi sedimentabile a aerului la punctul de


control din str. Muzeului nr 1 Ora Vlhia ca in anii anteriori. Cantitati maxime lunare
pentru pulberi sedimentabile sau incadrat in valorile maxime admise in tot timpul anului
62

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

2010, ce rezulta din graficele nr 1 si 2 anexate documentaiei concentraia maxima admisa


CMA fiind de 17 gr/mp /luna ( valoarea prevzuta in STAS 12574/ 1987 )
Fata de anii anteriori fiind o imbunatatirea eseniala.
Nu deinem alte determinri privind poluanii in aer din oraul Vlhia
c.

Calitatea solului

Analizele de sol realizate arata o uoara cretere a aciditii solului pdurilor din judeul
Harghita ( scderea pH ului cu circa 0,5 unitati) in corelaie cu scderea pH - ului
precipitaiilor. Astfel solurile pdurilor se ncadreaz in majoritatea cazurilor in categoria
solurilor slab acide. ,astfel se constata o reducere rapida a dezvoltrii rdcinilor la un pH
mai mic de cat 5.
Sunt poluate cu deeuri provenite din industria metalurgica (prin depozitarea in halde de
steril si iazuri de decantare pe o suprafaa de 2,83 ha terenuri in zona oraului Vlhia
producnd urmtoarele efecte negative: infiltrri de substane toxice, polund solul din
zona, respectiv apele subterane, chiar apele de suprafaa
5.2

EFECTE POTENIALE ALE ACTIVITILOR NVECINATE

In prezent pe terenurile nvecinate nu sunt unitati industriale poluatoare in functiune .


SC Metalurgica SA a fost inchisa: nu se cunoaste starea poluarii solulului in unitatiele care
au apartinut acestui complex industrial, fabrica ca atare, halda de zgura iazul de
decantare , cat si depozitul de deeuri al orasului Vlhia. Din punct de vedere al poluarii
apelor de suprafata si subterane este important a se cunoaste aceste efecte inspecial din
punctul de vedere al influentei datorat fenolitului folosit anterior la uzina metalurgica SA
cat si metale grele.
Concluzii
n ceea ce privete factorii de impact asupra mediului a activitilor istorice i prezente
pentru amplasamentul studiat se pot constata urmtoarele:
-nu s-au produs perturbri sau pierderi legate de folosirea terenurilor;
-nu s-au produs afectarea surselor de alimentare cu ap potabil;
-amplasamentul nu se afl n zon inundabil;
-condiiile atmosferice naturale se caracterizeaz prin;
vnturi puternice, micarea
maselor de aer, condiii bune de dispersie a gazelor;
-emisiile de poluani n aer, de la unitatea studiat este redusa i nu au avut efecte
majore negative asupra sntii oamenilor, florei, faunei.
-zona nu este caracterizat prin existena unor habitate sau ecosisteme valoroase;
-amplasamentul are o bun accesibilitate rutier;
-alimentarea cu energie electric se realizeaz de la S.T. 110 KV din apropierea platformei
Exploatarea instalaiilor de captare, tratarea si distribuirea apei se realizeaz in
concordanta cu autorizaia de gospodrire a apelor, Licena ANRSC, Autorizaie sanitara de
funcionare, dupa cum urmeaza:
Respectarea zonelor de protectie sanitara pentru captrile si instalatia de tratare
Staia tratare, ngrdit, personal de paza si supraveghere in permanenta inclusiv la sfrit
de saptamana si srbtori legale;
Sigurana funcionarii sistemului de alimentare este asigurata;
Urmrirea procesului tehnologic , prin laboratorul de analiza chimica este asigurata;

63

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Personal calificat pentru Operatiile executate;


Startarea instalatiior de tratare instalaiilor este corespunztoare;
Amplasamentul i activitile din zona adiacent pn-n prezent nu au provocat
controverse publice privind starea mediului;
Staia de epurare
Valorile medii ale principalilor parametrii ai apelor uzate, influente si efluente din staia de
epurare pe luni din cursul anului 2011 ( debit, CBO5, CCOcr) furnizat de beneficiar sunt
prezentate in tabelul anexat
Totodat sunt anexate buletinele de analiza privind principalii parametrii intrare-a iesirea cu
valori momentane a parametrilor determinate executat , la solicitarea beneficiarului de
catre SC Goscom SA Miercurea
Din buletinele analiza rezulta ca staia de epurare lucreaz cu randamente sub cele
prevzute prin normativele mai sus amintite, datorita tehnologiei aplicate nvechite, a uzurii
instalaiilor, cat si nefuncionarea unor pari a instalaiilor.
Pentru a atinge performantele prescrise in normativele specificate impuse, este necesar
procedeul de epurare biologica cu faza de denitrificare a apelor uzate
Este de menionat faptul ca staia de epurare nu a fost dotat cu instalatii de tratare a
nmolului rezultat , fiind prevzut cu sistemul de pompare pe halda de zgura a SC
Metalurgica SA , care in unele perioade nu funcioneaz.
Disfuncionaliti existente la staia de epurare
Lipsa unor obiecte componente sau operaii de baza in vederea funcionarii normale a
staiei pentru obinerea unor randamente corespunztoare ca:
grtar fin sau decantorul primar;
deznisipator;
faza de denitrificare
separator de grsimi;
instalaie de dezinfectare pentru ape uzate epurate;
gospodria de nmol.
Capacitate redusa a staiei de epurare , chiar pentru faza actuala nelund in calcul
perspectiva de dezvoltare si de racordare la canalizare si partea nordica localitii.
Totodat trebuie artat ca:
Nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial in proiect duce la
poluarea solului si a subsolului.
In prezent nmolul nu poate fi pompat pe halda de zgura din cauza ca instalatia este
defecta eventual poate fi vidanjat periodic si transportat pe platforma de uscare a statiei de
epurare din Miercurea Ciuc, din aria de operare al Harviz Sa . Este necesar ca in aceasta
faza, operaia sa fie executata conform reglementarilor legale .
Prezenta incrcrilor mari ale parametrilor de evacuare in unele perioade, datorita
neevacurii periodice a namolului, nefunctionarii concentratorului de nmol din staia de
pompare.
Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare, si ocazional realizate la Harviz Sa, din
Miercurea Ciuc. Sunt anexate buletine de analize ape uzate efectuate la SC Harviz SA
apelor uzate influente si efluente in staie de epurare.

64

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Fata de cele prezentate este necesar modernizarea staiei de epurare prin


retehnologizare reutilare, pentru a obine randamentele prescrise, respectarea
parametrilor de evacuare cat si mrirea capacitaii staiei innd cont ca o mare
parte a localitii inca nu beneficiaz de sistem de canalizare
In concluzie se poate arta c in baza probelor colectate din sol, analiza
deeurilor tehnologice, a msurtorilor si a analizelor fizico-chimice realizate in
timpul efecturii prezentului bilan de mediu, se va putea ntocmii bilanul de
mediu nivel II, in vederea stabilirii impactului asupra mediului prin activitatea
desfurat de Activitatea Captarea, tratarea si distribuirea apei, Respectiv
colectarea apelor uzate in oraul Vlhia, stabilirea unui proiect de program de
conformare, corespunztor obligaiilor de mediu in vederea ncadrrii in legislaia
actual de mediu.

S.C. TOTAL PROIECT S.R.L.

RAPORT
LA BILANUL DE MEDIU NIVEL II
INTRODUCERE
Investigaiile bilanului de mediu nivel II sunt cerute cnd se identific anticipat poluarea
unei zone sau cnd rezultatele bilanului de mediu nivel I ; indic o potenial poluare a
zonei i sunt necesare clarificri privind natura si intensitatea polurii identificate si trebuie
ntreprinse investigaii mai aprofundate pentru a se realiza o evaluare cantitativ a
nivelurilor de poluare din zona analizat. Tanant cont activitatea unitatii se rezuma in
special la colectarea si epurarea apelor uzate menajere si tip menajere din orasul Vlhia
investigatiile studiului se refera inspecial la verificarea incadrarii in normele legale privind
evacuarile de ape uzate epurate in apele de suprafata , cat si modul de gospodarire a
namolului rezultat din statia de epurare
Din descrierea tehnica a statiei de epurare prezentat in capitolele anterioare rezulta : Staia
de epurare este de tip mecano - biologic i are capacitatea proiectat de 16 l/s, care , ns
nu este de ajuns n momentul de fa, mai ales cnd partea nordic a oraului va fi
racordat la acest sistem. Este dotat cu debitmetru Parshall, - 1 bazin de aerare, - 2
aeratoare i pompe de nmol. Nmolul depus de la decantoare poate fi scos prin sifonare
prin 4 conducte in 4 cmine si din acestea prin gravitaie este introdus intr-un bazin de
depozitare. Din depozit nmolul a fost pompat cu o pompa tip ECV 80 la halda de zgura a
uzinei SC Metalurgica SA, sau vidanjarea periodica sau transportarea acestora pe fnee.
Evacuarea apelor uzate se realizeaz n prul Homorodul Mic adacent .
Investiia a fost executata in anul 1972, dupa tehnologia de la ceea vreme , din echiparea
staiei lipsind unele componente eseniale pt o funcionare eficienta , iar la stabilirea
parametrilor de evacuare sau luat in calcul diluia dupa evacuare in Homorodul Mic
( conform D.C.S. 414/1979 ) fiind stabilite valori relativ ridicate, ori prin apariia NTPA
001/1997 respectiv NTPA 001/2005,cat si NTPA011, legislaia impune noi masuri de
imbunatatirea a parametrilor de evacuare.

65

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Totodat este necesar de artat ca obiectivul o are o capacitate mult mai mica dect ceea
ce este necesar localitii in prezent, innd cont ca o mare parte a localitii nu este
canalizata , totodat nu este rezolvata nici problema nmolului stabilizat. Staia de epurare
lucreaz la un randament sczut, in (comparnd analizele realizate, fata de valorile NTPA
001/2005) aceste valori se situeaz n jurul valorii de 20-40 %, totodat nu este rezolvat n
cadrul staiei deznisiparea, degresarea, decantarea prealabil apelor uzate influente, i
dezinfectarea apelor epurate efluente, totodat prezint o problem i evacuarea i
depozitarea nmolului stabilizat.
Apele uzate efluente din staia de epurare au un coninut ridicat de Azot amoniacal, CBO5,
CCO cr fata de valorile admise prin Normativul sus amintit , dar in autorizaia de
Gospodrire a apelor nr 274/31.01.2012 innd cont de condiiile concrete din zona orasului
Vlhia sunt admise valori mai largi in aceasta perioada de realizare a dezvoltrii staiei de
epurare.
n ceea ce privete factorii de impact asupra mediului a activitilor istorice i prezente
pentru amplasamentul studiat se pot constata urmtoarele:

nu s-au produs perturbri sau pierderi legate de folosirea terenurilor;

nu s-au produs afectarea surselor de alimentare cu ap potabil;

amplasamentul nu se afl n zon inundabil;

condiiile atmosferice naturale se caracterizeaz prin;


vnturi puternice,
micarea maselor de aer, condiii bune de dispersie a gazelor;

emisiile de poluani n aer ,de la unitatea studiat este redusa i nu au avut


efecte majore negative asupra sntii oamenilor, florei, faunei.

zona nu este caracterizat prin existena unor habitate sau ecosisteme


valoroase;

Exploatarea instalaiilor de captare, tratarea si distribuirea apei se realizeaz in


concordanta cu autorizaia de gospodrire a apelor, Licena ANRSC, Autorizaie
sanitara de funcionare;

Respectarea zonelor de protectie sanitara pt captrile si instalatia de tratare

Staia tratare, ngrdit, personal de paza supraveghere pe tot timpul inclusiv la


sfrit de saptamana si srbtori legale;

Sigurana funcionarii sistemului de alimentare este asigurata;

Urmrirea procesului tehnologic , prin laboratorul de analiza chimica este


asigurata;

Personal calificat pt operatiile executate;

Startarea instalatiior de tratare instalaiilor este corespunztoare;

Amplasamentul i activitile din zona adiacent pn-n prezent nu au provocat


controverse publice privind starea mediului;

Staia de epurare. Valorile medii ale principalilor parametrii ai apelor uzate, influente si
efluente din staia de epurare pe luni din cursul anului 2011 (debit, CBO5, CCOcr) furnizat
de beneficiar sunt prezentate in tabelul anexat
Totodat sunt anexate buletinele de analiza privind principalii parametrii intrare-a esirea cu
valori momentane a parametrilor determinate executat, la solicitarea beneficiarului de catre
SC Goscom SA Miercurea Ciuc. Din buletinele analiza rezulta ca staia de epurare lucreaz
cu randamente sub cele prevzute prin normativele mai sus amintite, datorita tehnologiei
aplicate nvechite, a uzurii instalaiilor, cat si nefuncionarea unor pari a instalaiilor.

66

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Pentru a atinge performantele prescrise in normativele specificate impuse, este necesar


completarea tehnologiei de epurare cu faza de epurare biologica cu faza de denitrificare a
apelor uzate
Este de menionat faptul ca staia de epurare nu a fost dotat cu instalatii de tratare a
nmolului rezultat , fiind prevzut cu sistemul de pompare pe halda de zgura a SC
Metalurgica SA , care in unele perioade nu funcioneaz, ca si in prezent .
Disfuncionaliti existente la staia de epurare .Lipsa unor obiecte componente sau
operaii de baza in vederea funcionarii normale a staiei pentru obinerea unor
randamente corespunztoare ca:

grtar fin sau decantorul primar;

deznisipator;

faza de denitrificare

separator de grsimi;

instalaie de dezinfectare pentru ape uzate epurate;

gospodria de nmol.

capacitate redusa a staiei de epurare , chiar pt faza actuala nelund in calcul


perspectiva de fi legat la canalizare si partea nordica localitii.

Totodat trebuie artat ca:

Nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial in


proiect poate duce la poluarea solului si a subsolului

In prezent nmolul nu poate fi pompat pe halda de zgura din cauza ca instalatia


este defecta eventual poate fi vidanjat periodic si transportat pe terenuri
agricole. Este necesar ca aceasta faza , operaie sa fie executat conform
reglementarilor legale .

ncrcrile mari ale parametrilor de evacuare in unele perioade, datorita


neevacurii periodice a concentratorului de nmol din staia de pompare.

Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare, si ocazional realizate Goscom
Miercurea Ciuc. Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente si efluente in staie de epurare.
Fata de cele prezentate este necesar modernizarea staiei de epurare prin
retehnologizare reutilare, pt a obine randamentele prescrise, respectarea
parametrilor de evacuare cat si mrirea capacitaii staiei innd cont ca o mare
parte a localitii inca nu beneficiaz de sistem de canalizare
In concluzie se poate arta c in baza probelor colectate din sol, analiza deeurilor
tehnologice, a msurtorilor si a analizelor fizico-chimice realizate in timpul efecturii
prezentului bilan de mediu, sa putut ntocmii bilanul de mediu nivel II, in vederea stabilirii
impactului asupra mediului prin activitatea desfurat
, de
captarea, tratarea si
distribuirea apei, respectiv colectarea apelor uzate in oraul Vlhia, stabilirea unui proiect
de program de conformare, corespunztor obligaiilor de mediu in vederea ncadrrii in
legislaia actual de mediu.
In vederea stabilirii efectelor poteniale ale activitatii anterioare si prezente a statiei de
epurare Vlhia in cadrul Bilantului de Mediu Nivel II sa considerat necesar : evaluarea
polurii apelor de suprafata si subterane datorita functionarii cu dificultati a statiei de
epurare , depasirea concentratiilor unor parametrii de evacuare .Totodata sa studiat
gospodaria de namol , prin analize de laborator determinnd caracterul namolului
rezultat , existenta unor componente periculoase si toxice, recomandand posibilitati de

67

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

valorificare in cazul de fata cand nu functioneaza sistemul de evacuare pe terenul stabilit


prin avizul de gospodarire a apelor
In final se va prezenta succint componentele proiectului care este in derulare in vederea
reconstruirii statiei de epurare de capacitate corespunzatoare care va asigura grade de
epurare necesar pt apele uzate colectate din localitate studiata
Metodele de prelevarea probelor din diferite medii s-au conformat
normelor metodologice ct i standardele in vigoare.

reglementrilor si

6. DESCRIEREA SI REZULTATELE INVESTIGATIILOR


6.1 INVENTARIEREA SI EVALUAREA SURSELOR DE EMISII

6.1.1

POLUAREA APELOR DE SUPRAFATA SI SUBTERANE

Sursa principala a emisiilor de poluanti in apele de suprafata si subterane reprinta statia de


epurare a orasului Vlhia care datorita uzurii morale si fizice nu poate asigura randamente
corespunzatoare de epurare a apelor uzate menajere in condiile actuale . Schema
tehnologica de epurare folosita urmrete in mod special reinerea materiilor in suspensie,
a substanelor flotante, eliminarea substanelor biodegradabile exprimate prin CBO5.
Faze tehnologice de epurare a apelor uzate aplicate :
Prin epurarea mecanica are loc ndeprtarea in principal a materiilor in suspensie si a
substanelor separabile gravitaional, realizat cu ajutorul grtarului de reinere. Materiile
solide colectate se colecteaz in pube nchise si se transporta pe platforma de deseuri
menajere.
In bazinul de aerare, oxigenul necesar meninerii condiiilor vitale ale bacteriilor din cadrul
sistemului cu nmol activ este asigurat de instalaia de aerare generat de sistemul de
aerare cu turbine
2 x22 KW / se menioneaz eficienta slaba a acestetui sistem de
aerare ) . Apa menajera nmolul activ din spaiul bazinului de aerare ajunge prin sistemul
de distribuie central in decantorul secundar , in care sunt reinute particulele foarte fine ce
a ce duce la reducerea particulelor in suspensie , In spaiul de aerare se introduce oxigenul
necesar desfasurarii proceselor biochimice pe o durata de 2-3 ore , in timp care se
realizeaz omogenizarea apei uzate, aerului cat si a nmolului activat, - proces in care are
loc reducerea substanelor organice biodegradabile si a amoniacului. Nmolul in exces
stabilizat aerob se depoziteaz in concentratorul de nmol unde se compacta gravitaional
Nmolul depus de la decantoare poate evacuat prin sifonare prin 4 conducte in 4 cmine
si din acestea prin gravitaie introdus intr-un bazin de depozitare.
Din depozit nmolul poate fi pompat cu o pompa tip ECV 80 la halda de zgura a zonei SC
Metalurgica SA ( iniial ) , sau vidanjat periodic
Evacuarea apelor uzate se realizeaz n prul Homorodul Mic adiacent statiei de epurare .
Ape uzate tratabile cu ajutorul staiei de epurare sunt:
ape uzate fecaloid, menajere
Apele uzate menajere, provenite din apele folosite la splat si la alte activitati din
gospodarii, care conin in general spume, grsimi ,particule minerale fine si unele particule
organice si care sunt colectate prin obiecte sanitare obinuite (chiuvete, spltoare,
sifoane de pardoseala etc.)
Debite caracteristice influente.
Debite caracteristice a apelor uzate colectate ce urmeaz a fi epurate reale
Q zi med = 638,6 mc/zi = 7,39 l/sec
Q zi max =734,4 mc/zi = 8,50 l/sec
68

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Q or.max = 61,20 mc/h = 17,00 l/sec


Q or.min
= 6,39 mc/h = 1, 77 l/sec
Incarcarea apelor uzate influente
Apele uzate urbane influente n staia de epurare a oraului Vlhia se compune din ape
uzate menajere i ape uzate industriale. ncrcrile apelor uzate influente in staie de
epurare conform analizelor furnizate de operatorul staiei de epurare sunt urmtoarele:
pH
6,5-8,5
suspensii max .
300 mg/l
CBO5 max .
100 mg/l
CCO Cr
250 mg/l
azot amoniacal
10 mg/l
fosfor total
2,0 mgl
detergeni sintetic biodegradabili
5,0 mg/l
Parametrii de evacuare stabilii prin NTPA 001 /2005 si NTPA 0011
Dup epurare apele uzate sunt evacuate n prul Homorodul Mic parametrii de emisie
trebuie sa se ncadreze n valorile maxime stabilitate prin NTPA 001/2005 si NTPA 011 care
impune urmtoarele incarcari maxime
pH
6,5-8,5
Conform Aviz Ga 274 /
2012
suspensii max .
60 mg/l
120 mg/l
CBO5 max .
25 mg/l
150 mg/l
CCO Cr
125 mg/l
250 mg/l
substane extractibile n eter de petrol
20 mg/l
20 mg/l
azot amoniacal
3,0 mg/l
30 mg/l ( azot total
)
fosfor total
2,0 mg/l
detergeni sintetic biodegradabili
1,0 mg/l
clor rezidual liber
0,2 mg/l
temperatura
max. 40 C
Grade de epurare necesar
pt. suspensii : ds= Cuz-Cuz (adm)/Cuz x 100 = (300-60/300)x100 = 80,00 %
pt. CBO5
: dx= Xuz-Xuzadm/Xuz x 100 = (100-25/100)x100 = 75,00 %
pt CCO cr
: dy= yuz-yuz adm /yuz x 100 = ( 250-125 /100 ) = 50,00 %
Pentru atingerea valorilor impuse de NTPA 001/2005 si NTPA 0011/2005 este necesara
realizarea in cadrul procesului de epurare a urmtoarelor grade de epurare:
80 % pentru materii in suspensie.
75 % pentru consumul biochimic de oxigen
50 % pentru consumul chimic de oxigen ( CCO cr )
70 % pentru azot amoniacal
60 % pentru fosfor total
Pentru
atinge asemenea performante este necesar epurare mecano-biologica cu
denitrificare apelor uzate , nsa prezenta instalaie nu o poate realiza.
Gradul de epurare realizat
Din tabel anexa A , care prezint concentraii medii anuale a parametrilor influente si
efluente in staie de epurare pentru anul 2011, rezulta urmtoarele randamente de
reducere a noxelor in staia de epurare :
CBO5
cca. 21 %
CCO Cr
cca. 19 %
mat susp.- nu sunt date
PH se ncadreaz in valori legale
Debit anual orar 16,51 l/s.
69

TOTAL PROIECT SRL


ODORHEIU SECUIESC

6.1.2

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

DESCRIEREA SI REZULTATELE INVESTIGAIILOR

ANALIZE DE APA DE SUPRAFAA I SUBTERANE EXECUTATE


Ape uzate tehnologice evacuate de la statia de epurare oras Vlhia
Debitul
apelor
uzate
epurate
evacuate
Tab 2/1
Ziua
Debit zilnic l/s
pH
1
11
7,2
2
11
7,13
3
10,6
7,2
4
12
7,1
5
11
7,3
6
10
7,2
7
12
7,2
8
11
7.2
9
13
7,2
10
14
7,1
11
12
7,3
12
11
7.2
13
10
7.1
14
12
7,3
15
14
7,2
16
11
7,2
17
12
7,1
18
10
7,2
19
12
7,3
20
14
7,3
21
13
7,1
22
11
7,2
23
13
7,3
24
11,5
7,3
25
10,5
7,1
26
12
7,25
27
10,2
7,2
28
11
7,3
28
10,2
7,2
30
12
7,2
Media lunara
11,45
7,19
Volum lunar
30.672

iunie

CBO5

2012

Observatii

41,2

47,6

49,8

46,20

Diagrama , variatia debitului zilnic ape uzate epurate, evacuate

70

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Monitorizarea functionarii statiei de epurare din orasul Vlhia anul 2011


Tab 2/2
Perioad
a

CCOCr

CBO5

P tot

Cl-

Susp

mg/l

mg/l

mg/l

mg/l

mg/l

pH

NH4+

Obs

Luna
Admis
NTPA00
1

125

25

2,0

500

60

6,5-8,5

2,0-3,0

Admis
Conf GA
10.01.20

200

50

100

6,5-8,5

118

25

7,2

13,32

127

40

31,86

76

6.8

25,32

130

73

33,63

94

7,2

32,26

59

14

7,2

11,53

233

68

3,01

103

6,4

31,7

270

85

2,18

28,67

124

7,0

26,68

373

170

2,93

42,48

251

6,8

36,05

380

170

0,15

35,40

73

7,4

26,11

11
01.02.20
11
02.03.20
11
18.04.20
11
23.05.20
11
06.06.20
11
13.07.20
11
26.07.20
11

71

TOTAL PROIECT SRL


ODORHEIU SECUIESC

01.08.20

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

371

52

1,66

24,78

33

7,2

23,50

124

50

2,15

37,87

85

6,8

43,56

114

75

1,76

30,79

118

7,0

21,03

87

46

1,77

29,02

78

6,8

18,95

93

68

1,56

35,40

156

7,5

26,82

151

67

33,63

175

7,0

106

40

28,32

73

7,0

22,42

29

4,73

29,02

7,2

23,92

145

38,77

40,8

48

7,4

22

120

56,48

7,2

32,62

11
23.08.20
11
14.09.20
11
20.09.20
11
04.10.20
11
18.10.20
11
09.11.20

1,75

11
21.11.20
11
13.12.20

2,64

11
20.12.20

28,32

11
Nota * -Cifrele marcate cu rosu: depasiri
VARIATIA CONCENTRATIILOR POLUANTILOR IN APE UZATE EVACUATE IN ANUL
2011
Concentratia CBO5 in ape uzate evacuate din statia de epurare (mg/l )

72

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Concentratia CCOcr in ape uzate evacuate in mg/l

73

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Concentratia suspensiilor in ape uzate evacuate mg/l

Concentratia azotului amoniacal in ape uzate evacuate mg/l

74

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Concentratia fosforului in ape uzate evacuate mg/l

Probele de ap uzat colectate din canalizarea menajer intern, la punctul de evacuare n


receptorul natural , pune n eviden urmtoarele poluanti (conform buletinele de analiza
anexate)
PARAMETRII APELOR UZATE EVACUATE IN APE DE SUPRAFATA
In tabelul alturat este prezentat, evoluia principalilor indicatori de impurificate a apelor
uzate evacuate din unitate, n baza automonitoringului,si determinri ulterioare solicitate
de elaboratorul Bilanului, determinrile fiind realizate de laboratorul S.C. GOSCOM S.A.
Miercurea Ciuc si SGA Miercurea Ciuc.
Din tabelul de mai sus se observ c:

n ceea ce privete pH ul apelor se constata ncadrarea in valorile admise

la parametrul CCO cr si CBO5 sunt depasiri fata de valorile admise atat in ce a ce


priveste valorile maxime prevazute atat fata de NTPA 001/2005 cat s Autorizatia
GA inspecial in perioada verii ;

La parametrul suspensii sunt depasiri fata de valorile admise atat in ce a ce priveste


valorile maxime prevazute atat fata de NTPA 001/2005 cat s Autorizatia GA
inspecial in perioada calda ;

La paramterul azot amoniacal se constata depasiri substantiala atat fata de valorile


NTPA 001/2005 si Autorizatie GA datarita faptului ca procesul biologic de epurare
are randamente foarte scazute procesul de denitrificare practic nu exista ;

La parametrul substane extractibile se ncadreaz n valorile maxime admise.

Determinrile recente realizate arata ca concentraiile principalilor parametrii a


poluantilor n apele uzate evacuate din statia de epurare
depesc valorile
maxime admise in ape de suprafata in conformitate cu
prevederile
NTPA
001/2005 i cele prevzute n Autorizatie GA nr 274/20012 ,emis de ABA Olt
Unitatea are obligaia: s respecte parametrii de emisie a apelor uzate evacuate
n apele de suprafata , s se ncadreze n valorile maxime stabilitate prin
Autorizatia GA emis de ABA Olt
CONCLUZII

75

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Rezultatele analizelor prezentate in tabelele si graficele de mai sus arata


depasirea valorii concentratiilor maxime admise atat
fata de valorile NTPA
001/2005 cat si fata de Autorizatia de gospodarire a apelor in cazul CCOcr, CBO5,
suspensii, azot amoniacal , deci trebuie urgentat realizarea cat mai urgenta a
modernizarii statiei de epurare.
In problema calitatii apelor de suprafaa receptoare apelor uzate emise de la statia
de epurare se poate arata :
Conform datelor furnizate de Direcia Apelor, evaluarea calitatii rurilor si praielor, bazat
pe valorile caracteristice medii ale msurtorilor din anul 2011.
Dintre afluenii Oltului, pe prul Homorodul Mic in aval de oraul Vlhia,
calitatea apei sa incadrat in limitele clasei II att la grupa indicatori Regimul oxigenului
cat si la grupa Nutetrienti
ncadrarea seciunilor de supraveghere in categorii de calitate( in baza de msurtori )

Cursul de apa

Homorodul Mic

Vrghi

Seciunea
Aval Vlhia
Amonte Vlhia

Ordinul
II
II

Categoria de calit dpv fizico chimic


Ro I,
RO I

GM I
GM I

TS D
TS -

*RO regim de oxigenare ,GM grad de mineralizare ,TS toxice si speciale ,TI toi
indicatorii
Este de mentionat faptul ca in cazul anotimpului secetos cand debitul paraului
este redus , ca si in vara anului 2012 , poluarea apelor paraului poate fi
semnificativa
6.2 POLUAREA SOLULUI

6.2.1

SURSE DE POLARE A SOLULUI

Namolul in exces trebuie periodic eliminat din spatiu de reactie ( din decantor) . In proiectul
initial a fost prevazut ca nmolul depus de la decantoare este scos prin sifonare prin 4
conducte in 4 cmine si din acestea prin gravitaie este introdus intr-un bazin de depozitare.
Din depozit nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a zonei SC
Metalurgica SA ( iniial ) , sau vidanjat periodic , unde va fi uscat si ulterior utilizat ca
fertilizator pt soluri
In nprezent acest sistem nu functioneaza din cauza unor defectarii instalatiilor de transport
namol fluid iar namolul in ultimul timp nu a fost evacuat din decantor astfel exista o
cantitate apreciabila acumulata . Namolul in suspensie odata cu functionarea sistemului
de aerare este poate efi evacuat cu apele epurate marind concentratia materialelor in
suspensie
Este important ca namolul sa fie evacuat conform procesului tehnologic stabilit , chiar si in
cazul ca sistemul de evacuare prin pompare este defect
In cursul intocmirii bilantului de mediu Nivel II am considerat foarte important ca
sa determinam caracterul si eventual daca contine unele elemente toxice sau
periculoase pt care nu poate fi utilizat in agricultura, dupa desdiratare. In acest
sens
prin raportul de incercare nr 122153/12.11.2012
sa determinat ,
caracteristicile fizice, , componentele , chimice, continulutul de metale grele
toxice, PAH, PCB , astfel , ca in conformitate cu Ordinele MMGA 344 /2004 si
708/2004
MAPDR
demonstrand ca poate fi utilizat in agricultura , dupa
deshidratare
Din activitatea desfurat pe amplasament n timpul funcionarii obiectivului rezult
urmtoarele tipuri de deeuri, codificate conform Catalogului European al Deeurilor:

nmoluri de la epurarea efluenilor proprii: 02 07 05;


76

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

reineri de la grtare, nisipuri, nmoluri de la epurarea apelor uzate municipale: 19


08 05.

Directiva 86/278/EC privind proecia mediului, n special a solului, atunci cnd se utilizeaz
nmoluri de epurare n agricultur, amendat de Directiva 91/692/CE i de Regulamentul
(CE) nr. 807/2003, transpus n legislaia naional prin O.M. nr. 344/ 2004 pentru aprobarea
Normelor tehnice privind protecia mediului i n special a solurilor, cnd se utilizeaz
nmolurile de epurare n agricultur.
Astfel , In cazul n care calitatea nmolului de la staia de epurare nu este pretabil folosirii
n agricultur, staia de epurare va trebui s gseasc alte modaliti de eliminare a
nmolului. Una dintre aceste posibiliti poate fi eliminarea nmolului din staii de epurare
de ape uzate menajer la depozitul de deeuri nepericuloase cu respectarea prevederilor
BAT-lui pentru depozite ( coninut de umiditate max. 65% i depunerea pe depozit
amestecat cu deeurile menajere n proporie 1:10)
Conform SR 13400, nmolurile provenite de la staiile de epurare oreneti dup treapta
de epurare biologic i fermentare, deshidratare de pe platformele de uscare sau instalaiile
mecanice de deshidratare cu o umiditate de 65%, se pot depozita numai n depozite
controlate. Oraul Vlhia nu are amenajat depozit de deeuri menajere controlate.
Nmolurile concentrate pot fi depuse prin pompare pe halda unitatii SC Metalurgica SA ,
amenajat , conform autorizatiei de gospodarire a apelor ,sau vidanjate transportate pe
fnei, dar in prezent instalatia este defecta.
Reinerile de grtar, nmolurile brute, deshidratate, trebuie ndeprtate din staia
de epurare.
Nmolul format in statia de epurare va trebui sa fie evacuat , ori pe platforma de
dehidratare locala sau alte platforme de statii de epurare autorizate. Namolul din
statia de epurare Vlhia nu contine componente toxice si dupa deshidratare pot
fi utilizate in agricultura , conform leglementarilor legale.
Cantitatea total de materiale rezultate din procesul de epurare:
Nmol concentrat din staia de epurare cu coninut de substana uscata cca. 165 kg/zi s.u.
cca62 to/an
Substane solide reinute pe grtare cca. 25 kg/zi 9 to/an colectat in conteiner si depuse
la halda de deseuri locale.
6.2.2

REZULTATELE DETERMINARII REALIZATE

Raport de incercare nr 122153/12.112012- executat de Laboratorul Chimic Wessling


Romania anexat documentatiei .Cod proba 2875: Namol din statie de epurare Vlhia Data
recoltarii probei 05.10.2012
Rezultate :
pH
5,91
Umiditate 26,1 %
Continut de substanta uscata ; 73,9 %
Azot total 5,25 g/kg
Elemente ( inclusiv metale grele ) :
Cadmiu 2,88
mg/kg valori maxime admise 10,00 mg/kg
Crom
26,4
mg/kg valori maxime admise 500,0 mg/kg
Cupru
280
mg/kg valori maxime admise 500,0 mg/kg
Mercur 0,542 mg/kg valori maxime admise
5,0 mg/kg
Nichel
17,8
mg/kg valori maxime admise
100,0 mg/kg
Plumb 80,3
mg/kg valori maxime admise
300,0 mg/kg
Zinc
407
mg/kg valori maxime admise 2000,0 mg/kg

77

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

78

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Hidrocarburi poliaromatice PAH 1,68 mg/kg


Naftalina 0,058
mg/kg
Fenantren 0,168
mg/kg
Antracen 0,028
mg/kg
Fluorantren 0,204
mg/kg
Piren 0,310
mg/kg
Benzantracen 0,098
mg/kg
Crisen 0,271
mg/kg
Benzo ( b) fluorantren 0,088 mg/kg
Benzo ( k) fluorantren 0,090 mg/kg
Benz ( e ) piren 0,135
mg/kg
Benz (a)piren 0,076
mg/kg
Indenopiren 0,075
mg/kg
Benzo perilen 0,079
mg/kg
Diagrama privind concentratia PAH in namol ,
Ordinul MMGA nr 344/2004

Paramet Val ori


Val
ru
Determi Norm.
nate
PCB
1,68

Valori
alerta
3,50

fata de valorile admise prin

Valori
Interven
tie
5,00

79

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

PCB ( bifenili clorurati ) total 0,13 mg/kg compus din :


PCB 28 - 0,10 mg/kg
PCB 52 0,03 mg/kg
PCB 101 < 0,01mg/kg
PCB 118 <0,01 mg/kg
PCB 153 <0,01 mg/kg
PCB 138 <0,01 mg/kg
PCB 180 <0,01 mg/kg
Diagrama privind concentratia PAH in namol ,
Ordinul MMGA nr 344/2004
Paramet Val ori
ru
Determi
nate
PCB
0,13

Val
Norm.

fata de valorile admise prin

Valori
alerta
0,56

Carbon organic total TOC 7,3 % ( m/m )

Halogenuri absorbabile total ( AOX ) 88 % ( m/m )

Valori
Interven
tie
0,80

80

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Conxluzii. Din datele prezentate rezulta ca namolul din statia de epurare al orasului Vlhia
, nu contine componente periculoase peste valorile maxime admise prin Ordinul MMGA nr
344/2004 , si deshidratat poate fi utilizat ca fertilizant in agricultura cu respectarea
conditiilor prescrise in documentul respectiv
Propunem ca namolul din decantorul statiei sa fie vidanjat si transportat la statia
de epurare Miercurea Ciuc si impreuna cu namolul de la amplasamentul respectiv
sa fie deshidratat si utilizat ca fertilizant , sau depus in depozit de deeuri
menajere
6.3 POLUAREA AERULUI

Surse de emisii de poluani in aer


n cadrul staiei, epurare a apelor uzate se realizeaz prin metoda aerob, n aceast
situaie emisiile de poluanti i mirosuri sunt neglijabile, n cazul neasigurrii funcionrii la
parametrii proiectai, pot fi evacuate n atmosfer urmtoarele poluani a cror valoare
olfactiv (VO) prezint valori ridicate:

hidrogenul sulfurat, degaj un miros de ou stricat foarte puternic;

mercaptani ( metilmercaptan, etilmercaptan) elibereaz un miros de varz stricat;

amoniacul prezint un miros neptor;

aminele ( metilamina, - prezint un miros de pete foarte pronunat;

acizi organici: acid acetic, acid butiric, acid valeric cu miros puternic i neptor;

aldehid butiric cu miros rnced;

aldehid izovaleric cu miros neplcut de mr stricat.

Valoarea olfactiv ( VO ) reprezint raportul dintre tensiunea de vapori saturai a unei


substane i concentraia limit de percepere, se utilizeaz ca unitate de msur pentru
aprecierea cantitativ a mirosului.
Procedeele de tratare a nmolurilor sunt multiple i variate, fiecare obiectiv trebuie studiat
n condiiile sale specifice, documentaia prezentat trateaz prelucrarea nmolurilor prin
procedeul de prelucrare mecanic dinamic i paturi de deshidratare.
Principala surs de poluare pentru aer de pe amplasament reprezint noxele rezultate din ;
colectarea i depozitarea n condiii necorespunztoare a reinerilor de la grtare, din
fermentarea anaerob i aerob a nmolurilor rezultate din concentratorul de nmol i
depozitat in bazinul de nmol .
Conform reglementarilor legale concentraiile maxime a noxelor in aerul zonelor protejate
nu trebuie sa se depaseasca cele prevzute prin Legea nr 104/2011 si STAS 12574/1987,
iar pentru substanele nespecificate in acest document ele sa nu prezinte mirosuri olfactive
si persistente.
ncadrare in norme legale:
Emisiile sub form de pulberi rezultate din ntreaga activitate desfurat pe amplasament
nu trebuie s depeasc 50 mg/mc la un debit masic de 0,5 kg/h, la o dimensiune a
diametrului mediu al particulelor (dp) 5 nm, n conformitate cu reglementrile legale :
Ordin MAPPM nr 462/1993 .
Mirosuri Statie de epurare . In unele perioade , inspecial vara , exista mirosuri persistente
dezagreabile datorita nefuncionrii corespunztoare a procesului de epurare de aceea
este foarte urgent necesar retehnologizarea staiei de epurare.

81

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

In cursul realizarii bilantului de mediu nu am avut posibilitatea de a pune in evidenta


masurabila existenta mirosurilor . Dealtfel din consultarea vecinilor nu au fost sesizate
reclamatii in acest sens
Din cauza ca la statia de epurare emisii de poluanti sub forma de pulberi in suspensie sau
pulberi sedimentabile practic nu exista , nu sa considerat a se efectua analize in acest
sens.
7. CONCLUZII SI RECOMANDARI
Staia de epurare
Valorile medii ale principalelor parametrii ai apelor uzate, influente si efluente din staia de
epurare calculate pe luni din cursul anului 2011 (debit, CBO 5 CCOcr ) furnizat de beneficiar
sunt prezentate in tabelul anexat
Totodat sunt anexate buletinele de analiza privind principalii parametrii intrare-a esirea cu
valori momentane a parametrilor determinate executat , la solicitarea beneficiarului de
catre SC Goscom SA Miercurea
Din buletinele analiza rezulta ca staia de epurare lucreaz cu randamente sub cele
prevzute prin normativele mai sus amintite, datorita tehnologiei aplicate nvechite, a
uzurii instalaiilor, cat si nefuncionarea unor pari a instalaiilor
Pentru a atinge performantele prescrise in normativele specificate impuse , este necesar
procedeul de epurare biologica cu faza de denitrificare a apelor uzate
Este de menionat faptul ca staia de epurare nu a fost dotat cu instalatii de tratare a
nmolului rezultat , fiind prevzut cu sistemul de pompare pe halda de zgura a SC
Metalurgica SA , care in unele perioade nu funcioneaz.

Disfuncionaliti existente la staia de epurare


Lipsa unor obiecte componente sau operaii de baza in vederea funcionarii normale a
staiei pentru obinerea unor randamente corespunztoare ca:

grtar fin sau decantorul primar;

deznisipator;

faza de denitrificare

separator de grsimi;

instalaie de dezinfectare pentru ape uzate epurate;

gospodria de nmol.

Capacitate redusa a staiei de epurare , chiar pt faza actuala nelund in calcul perspectiva
de fi legat la canalizare si partea nordica localitii.
Totodat trebuie artat ca:
Nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial in proiect poate
duce la poluarea solului si a subsolului
Neevacuarea la timp a namolului din statia de epurare duce
defectuoasa a statiei de epurare

functionarea

si mai

In prezent nmolul nu poate fi pompat pe halda de zgura din cauza ca instalatia este
defecta eventual poate fi vidanjat periodic si transportat pe terenuri agricole. Este necesar
ca aceasta faza , operaie sa fie executat conform reglementarilor legale .

82

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare, si ocazional realizate Goscom
Miercurea Ciuc. Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente si efluente in staie de epurare.
In concluzie se poate arta c in baza datelor inregistrate privind parametrii de
evacuare din statia de epurare realizate atat in laboratorul propriu si ce realizat
de Goscom SA a , cat si cele realizate in timpul efecturii prezentului bilan se
constata ca statia de epurare nu poate asigura randamente corespuzatoare in
procesul de de epurare a apelor uzate , principalii parametrii de evacuare
depasind valorile maxime admise .
Analiza deeurilor tehnologice, respectiv a namolului din statia de epurare ,
rezulta ca acesta nu contine componente periculoase , deci dupa evacuare si
deshidratare corespunzatoare poate fi utilizata in agricultura in conformitate cu
prevederile " Ordinul comun M.M.G.A. nr. 344/2004 si M.A.P.D.R. nr 708/2004 pentru
aprobarea Normelor tehnice privind protectia mediului si inspecial a solurilor cand se
utilizeaza namolurile de epurare in agricultura."
Fata de cele prezentate este necesar modernizarea staiei de epurare prin
retehnologizare reutilare, pt a obine randamentele prescrise, respectarea
parametrilor de evacuare cat si mrirea capacitaii staiei innd cont ca o mare
parte a localitii inca nu beneficiaz de sistem de canalizare
8. PROPUNERI PENTRU PROGRAME DE CONFORMARE
8.1

PROPUNERI PT MODERNIZAREA STATIEI DE EPURARE

Prezentul memoriu tehnic trateaz obiectele tehnologice din cadru staiei de epurare din
punct de vedere al instalaiilor hidraulice, pneumatice.
Obiecte tratate :
Bazin de primire a vidanjului;
Cmin deversor;
Grtar mecanic;
Staie de pompare;
Deznisipator aerat cuplat cu separator de grsimi;
Bazin de aerare prelungit i decantor secundar radial;
Bazin de contact cu clorul;
Cmin debitmetru;
Concentrator de nmol;
Staie de preparare soluii chimice;
Staie de filtre deshidratare nmol;
Reele tehnologice interioare incint:
Canal de ocolire staie epurare i pe perioada execuiei;
Conduct ap uzat menajer, ap epurat,
Conduct ape uzate tehnologice(supernatant, filtrat, etc);
Conduct nmol stabilizat;
Branament de ap potabil i incendiu;
Bazin pentru preluarea vidanjului .Are rolul de preluare a vidanjului transportat, din
zonele necanalizate i din satele aparintoare comunei. Evacuarea nmolului n camera
grtarului mecanic se va face la debite maxime, pentru evitarea ocului n treapta
biologic.
Bazinul adpostete un mixer i o electropomp submersibil pentru evacuarea apei uzate
fecaloide, ce se face printr-o conduct din polietilen cu De = 90 mm cu Pn 6 bar.

83

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Cmin deversor .Cminul deversor are rolul de a dirija apele uzate influente n cuva
grtarului, iar n cazul n care apare o defeciune major ( pan de curent ) apele uzate sunt
evacuate prin deversare n conducta de ocolire i canalul de evacuare a apelor pluviale.
Grtar mecanic .Reinerea materialelor grosiere, trte, n suspensie i plutitoare, cu
dimensiunile de peste 5 mm, se va realiza prin montarea unei site rotative automate din
oel inox ntr-o cuv de beton armat cu lungimea de 2,50 m i limea de 50 cm, reinerile
de grtar sunt presate i evacuate n saci.
Saci se depoziteaz pe o platform betonat iar levigatul este evacuat n cminul CM4, prin
tuburi PVC cu De = 160 mm.
Desnisipator aerat cuplat cu separator de grsimI .Pentru reinerea materiilor
granulare cu dimensiunile de peste 0,2 mm i cu densitatea mai mare dect a apei (nisip) i
a materiilor mai uoare dect apa (grsimi, produse petroliere) se prevede un desnisipator
aerat cuplat cu separator de grsimi, cu capacitatea de 80 l/sec.
Desnisipatorul aerat, cu curgerea n spiral este proiectat s rein nisipul i alte materiale
granulare grele din curentul de ape uzate.Nisipul splat, sedimentat din compartimentul de
deznisipare este evacuat periodic.
Grsimile, uleiurile i produsele petroliere ridicate la suprafaa compartimentului de
separare i mpinse n recipientul de colectare, vor fi evacuate gravitaional la o vidanj ce
va staiona lateral cu hala existent, printr-o conduct de descrcare din oel Dn 100
mm(108x4 mm) pe care se prevede o van de nchidere cu sertar.
Conductele se vor susine cu supori ancorai n elementele de beton armat.
Toate prile metalice ale instalaiilor hidraulice( coturi, reducii, supori, tije de manevr,
flane i tronsoane de conduct ) vor fi protejate contra coroziunii prin imersarea ntr-o baie
de zinc topit(zincare termic), dup o curare atent de rugin cu peria de srm sau prin
alte procedee mecanice sau chimice corespunztoare.
Bazine cu aerare prelungit cu nmol activ .Funcionarea acestui obiect este descris
n memoriul de tehnologie.Instalaiile hidraulice aferente acestui bazin constau din intrarea
conductei de ap uzat de la deznisipator, i plecarea amestecului de ap-nmol spre
decantorul secundar dup o aerare prelungit.
Intrarea conductei se va realiza n peretele bazinului de aerare prin intermediul unei piese
de trecere pentru Dn 200mm din PVC.
Ieirea amestecului ap - nmol este dirijat n tubul central al decantorului secundar, iar
apa decantat este colectat prin jghiabul perimetral i evacuat spre bazinul de clorinare
printr-un tub PVC cu De = 200mm.
Instalaiile pneumatice aferente acestui bazin constau dintr-o conduct de distribuie aer
comprimat ce va nconjura bazinul de aerare i va fi alimentat de la staia de suflante
printr-o conduct de refulare i conducte de alimentare racordate la aceast conduct de
distribuie care vor ajunge n bazin prin goluri practicate deasupra nivelului lichidului,
conducte la care se vor racorda instalaiile de aerare cu bule fine.
Conducta periferic, se va executa din eav de PEID de Dn 110 mm Pn 6 bar, va fi montat
n pmnt la execuia bazinului i va fi susinut cu supori prini n peretele acestui bazin.
Conducta va alimenta cele 6 instalaii de aerare pe ambele pri.
Conductele de alimentare a instalaiilor de aerare se vor executa din eav PEID De 110 mm
i vor fi prevzute cu robinete de reglare i nchidere din PEID cu mner fluture.
Deasemenea nspre instalaiile de aerare ele vor avea racorduri de prindere cu clem inox.
Trecerea prin peretele periferic al bazinului se va realiza cu ajutorul unor piese de trecere tip
B metalice nglobate la turnarea betonului armat.
Conductele se vor susine cu supori ancorai n elementele de beton armat.

84

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Toate prile metalice ale instalaiilor hidraulice( coturi, reducii, supori, tije de manevr,
flane i tronsoane de conduct) vor fi protejate contra coroziunii prin galvanizare la cald.
Instalaiile hidraulice i pneumatice sunt redate n plana 02/04/I1 i cantitile n tabelele i
listele de cantiti aferente.
Concentratorul de nmol .Descrierea funcionrii acestui obiect se face n memoriul de
tehnologie.
Instalaiile hidraulice aferente acestui siloz constau din conducta de evacuare a nmolului
activat racordat la cele dou pompe cu urub din staia de filtre de deshidratare a
nmolului i pompa de evacuare a supernatantului.
Conducta de evacuare a nmolului se va executa din eav PE cu De 110 mm.
Pompa de evacuare a supernatantului va fi montat pe un postament ce poate fi fixat la o
adncime dorit pe un ghidaj metalic. De aceast pomp se ataeaz, cu ajutorul unor
cleme, un furtun flexibil de cauciuc cu estur textil D 2 care va fi racordat la conducta
de evacuare (conducta de preaplin) a silozului de nmol.
Conductele se vor susine cu supori ancorai n elementele de beton armat.
Toate prile metalice ale instalaiilor hidraulice( supori, tije de manevr, flane, tronsoane
de conduct, coturi ) vor fi protejate contra coroziunii prin imersarea ntr-o baie de zinc
topit(zincare termic), dup o curare atent de rugin cu peria de srm sau prin alte
procedee mecanice sau chimice corespunztoare.
Camera instalaiei de dozare chimicale .Laptele de var se va prepara prin dizolvarea
varului stins, aprovizionat n saci de 50 kg, ntr-un recipient cu amestector cu volumul de 3
- 4 mc, i va avea concentraia de 1-2%. Din acest vas, soluia de lapte de var se va doza n
conducta de alimentare a blocului combinat de aerare prelungit i decantare secundar,
prin injectarea sa n condcuta montat n galeria de conducte din apropiere. Pentru dozarea
laptelui de var se prevede o pomp de dozare corespunztoare, reglabil.
Soluia de sulfat feros se va prepara deasemenea n dou recipiente de polietilen cu
amestector i capacitatea de 1 mc, iar dozarea se va realiza cu dou pompe de dozare
corespunztoare, direct n conducta de alimentare a desnisipatorului aerat.
Staia de suflante .Instalaia pneumatic const din cte un robinet de nchidere i
reglare pe conductele de refulare, din conductele respective cu piese ca coturi, reducii,
teuri.
Pentru msurarea debitului furnizat de suflantele de alimentare a bazinului de aerare
prelungit se va monta pe conducta colectoare o diafragm de msurare racordat printr-o
baterie de robinei la un aparat de msur diferenial
Funcionarea suflantelor se va face automatizat funcie de coninutul de oxigen dizolvat din
apa din bazinul de aerare.
Pe conductele de refulare ale suflantelor de capacitate mare se va monta cte un
manometru cu robinet de control i conduct de atenuare a vibraiilor umplut cu glicerol.
Toate prile metalice ale instalaiilor hidraulice(supori, flane, tronsoane de conduct, tije
de manevr, coturi) vor fi protejate contra coroziunii prin imersarea ntr-o baie de zinc
topit(zincare termic), dup o curare atent de rugin cu peria de srm sau prin alte
procedee mecanice sau chimice corespunztoare.
Conductele de aer comprimat se pozeaz pe peretele dinspre exterior, pe supori metalici.
Ele vor fi semnalizate pentru ca operatorul i persoane strine s nu le ating, dat fiindc
temperatura peretelui acestor conducte poate atinge 100oC, deci e pericol de arsuri.
Dat fiind c prin comprimarea aerului i prin funcionarea motoarelor i suflantelor se
elibereaz o cantitate mare de cldur se prevede i o instalaie de ventilare mecanic
compus dintr-un ventilator de perete cu D 400 mm, montat n partea superioar a
85

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

peretelui dinspre galeria de conducte. Acest ventilator va refula aerul nclzit, prin canale
de ventilaie executate din tabl neagr protejat cu vopsele rezistente la temperaturi
ridicate, n exterior pe perioada cald.
Dirijarea curentului de aer cald se va realiza cu dou ibere, unul pe conducta cu exteriorul
i al doilea pe conducta spre sala separatorului de nisip.
Conducta de aer comprimat va iei din sala staiei de suflante care va cobor, ptrunde n
subteran i se va racorda la conducta de transport a aerului comprimat la bazinul de aerare.
Deshidratare nmol stabilizat .Aceast ncpere va fi comun cu spaiul destinat
grtarului mecanic pentru deshidratarea nmolului stabilizat.Recipienii cu agitatoare
pentru prepararea soluiilor de polielectrolii (polimeri) necesare condiionrii nmolului
naintea deshidratrii se vor amplasa lng instalaia de sitare.
Pentru realizarea acestor funciuni, spaiul destinat acestei staii va fi prevzut cu o
instalaie de ap potabil alimentat de la branamentul de ap potabil din exterior. Apele
uzate produse ocazional la prepararea soluiilor vor fi preluate prin sifoane de pardoseal
prevzute i conduse la un recipient amplasat n exteriorul cldirii. n acest recipient se vor
face determinri ale pH-ului, se va realiza neutralizarea apelor uzate i numai dup aceasta
se va evacua la reeaua de canalizare a supernatantului i filtratului din incint.
Conducta de ap potabil va fi din PVC tip G Dn 32-50 mm, pozat pe peretele galeriei de
conducte i al ncperii destinate staiei de filtre de nmol i al staiei de preparare a
soluiilor chimice. Ea va alimenta o chiuvet de perete precum i consumatorii ( recipienii
de preparare a soluiilor de polielectrolii, a laptelui de var, a soluiei de sulfat feros,
splarea benzilor filtrelor) prin robinei de trecere cu racord pentru furtun D -1 1/4.
REELE TEHNOLOGICE INCINTA STAIE DE EPURARE
Canalizare ape pluviale Apa uzat intr n staia de epurare prin colectorul principal din
tuburi PVC cu De 200 mm. Pe acest colector se prevede un cmin de vizitare i un cmin de
deversare, din care o conduct de 3,0 m transport apa uzat n camera grtarului.
De la cuva sitei rotative apa uzat curat de materiile n suspensie, trte i plutitoare cu
dimensiunile de peste 5 mm este canalizat n deznisipatorul aerat i separatorul de
grsimi.
Din deznisipatorul aerat, respectiv de la instalaia hidraulic aferent apa deznisipat i
degresat se canalizeaz n cminul de distribuie printr-o conduct subteran din PVC, Dn
200 mm.Din cminul de distribuie apa uzat se repartizeaz n cele trei bazine de aerare i
decantare prin conducte PVC Dn 200 mm
Din cele trei decantoare secundare apa epurat va trece n bazinul de contact cu clorul
printr-o conduct de PVC Dn 200 mm.
Din bazinul de contact cu clorul apa dezinfecat va traversa debitmetrul electromagnetic i
canalizat n cminul de intersecie cu canalizarea pluvial, din acest cmin evacuarea se
va face printr-o conduct din PVC Dn 315 mm cu lungimea de 25 metri pozat subteran.
Conduct de nmol stabilizat .Nmolul activ n exces va fi evacuat n bazinul de aerare
prin aer lift n concentratorul de nmol.Din concentrator nmolul este evacuat n instalaia
de deshidratare cu saci. Evacuarea se va face prin tuburi din PE cu De = 160 mm, pe o
lungime de L = 33m.
Canale ape uzate tehnologice
Colectarea apelor uzate tehnologice se va realiza printr-o reea de canalizare subteran din
tuburi PVC Dn 50 mm, iar canalizarea grupului sanitar se va face prin tuburi PVC Dn 110
mm.

86

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Conducta de hipoclorit .Soluia de clor, hipoclorit, va fi transportat la bazinul de contact


cu clorul, printr-o conduct subteran din eav PE cu De 20 mm cu lungimea de 34 metri.
Canal ocolire staie .Pentru evacuarea surplusului de ape de ploaie fa de debitul maxim
de calcul se prevede execuia unui canal de ocolire a staiei de epurare din tuburi PVC cu De
250 mm cu o lungime de 52 metri.
Branament ap potabil i surs de ap pentru stins incendii . Alimentarea cu ap
potabil a staiei de epurare se va realiza prin execuia unui branament la reeaua de
distribuie stradal, care va asigura apa necesar nevoilor igienico - sanitare. Branamentul
se va executa din eav de PEHD Pn 6 at De 32 mm montat n pmnt. Pe branament se
prevede un cmin pentru apometru.
Apa necesar pentru stins incendii, ap tehnologic i pentru ntreinerea spaiilor verzi sa
prevzut pomparea apei din cminul colector a apei drenante.
Conducta se execut din PE cu De = 110 mm, i are lungimea de 106 m i se vor monta 3
hidrani.
8.2 PROPUNERI PT GOSPODARIREA DESEURILOR

Pana la realizarea si punerea in functiune a investitiei de modernizare a statiei de epurare


Vlhia Operatorul are sarcina de a vidanja si transporta namolul din decantorul statiei la o
statie de epurare in vederea dehidratarii , in vederea utilizarii acestuia conform
reglementarilor legale
Dupa reaizarea investitiei namol va fi gospodarit conform tehnologiei prescrise , si
Autorizatie de Gospodarire a apelor.
8.3 PROPUNERI PT MONITORIZAREA TEHNOLOGICA

Operatorul va fi dotat cu aparatura necesar pentru controlul emisiilor de poluani in


mediu, supravegherea calitii factorilor de mediu si monitorizarea activitilor destinate
proteciei mediului.
Debitmetrul electromagnetic instalat n staia de epurare msoar debitul de ap uzat pe
fiecare linie de pompare. Citirea acestuia se poate face fie local pe display, fie centralizat
din calculatorul de proces (opional). Acest obiect tehnologic este amplasat amonte de
modulul biologic de epurare, rezultnd o eviden precis a debitelor de ap uzat epurat.
Se va urmrii prin analize in conformitate cu prescripiile normativului NTPA 001, NTPA 002
i NTPA 011, principalii ncrcri maxime influente si efluente in staia de epurare:
pH ; uniti pH
Materii n suspensie mg/dm3
Consum biochimic de oxigen la 5 zile (CBO5) mg O2/dm3
Consum chimic de oxigen - metoda cu mg O2/dm3
Azot amoniacal (NH4 +) mg/dm3
Azot total
Fosfor total (P) mg/dm3
Substane extractibile cu solveni organici mg/dm3
Detergeni sintetici biodegradabili mg/dm3
87

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Totodat se va tine evidenta deeurilor produse dup punerea in funciune a obiectivului in


conformitate cu prevederile HGR nr. 856/2004.
9. SCURT REFERAT NETEHNIC
Prezenta lucrare s-a ntocmit la solicitarea Societii Comerciale HARVIZ SA
MIERCUREA CIUC Str. Salcm nr 1 Judeul Harghita Operator pentru serviciul public de
alimentare cu apa si de canalizare al orasului Vlhia in baza Ordinului preedintelui ANRSC
nr 574/03.10.2011, cat si in baza contractului de Delegare a Gestiunii nr 34/01.09.2009
ncheiat cu Asociaia de Dezvoltare Intercomunitara HARGHITA VIZ in oraul Vlhia.
Societatea Comerciala SC Harviz SA cu sediul social Municipiul Miercurea Ciuc Str. Salcm
nr 1 Judeul Harghita Cod Unic de nregistrare 24499588 /23.09.2008 Nr ordine in registrul
comerului J19/917/22.09.2008 avnd activitatea principala Captarea tratarea si distribuia
apei cod CAEN 4100.
Bilanul de mediu este necesar n procesul de autorizare in vederea stabilirii elementelor
programului de conformare . Prin bilanul de mediu se va evalua impactul asupra mediului
prin studii teoretice investigaii realizate la fata locului , msurtori de noxe emise in apa
aer si sol , efectuate asupra obiectivului CAPTAREA ; TRATAREA SI DISTRIBUIA
APEI RESPECTIV COLECTAREA SI TRATAREA APELOR UZATE IN ORASUL VLHIA
si care este situat n intravilanul si extravilanul orasului Vlhia Judeul Harghita.
Scopul studiului este de a analiza efectul activitilor din unitatea studiat asupra factorilor
de mediu i de a identifica ariile cheie de importan din punct de vedere al mediului
nconjurtor determinate pentru desfurarea activitii viitoare pe amplasamentul
studiat.Aceast analiz are loc n procesul de autorizare a unitatii susmenionate, solicitata
de Agenia pentru protectia Mediului Harghita cu ndrumarul nr. 6155/20 iunie 2011 in
vederea determinrii strii de poluarea factorilor de mediu, starea i eficiena funcionrii
sistemelor de epurarea a apelor uzate existente sau cele necesare, restriciile existente n
zon, pt. a se ncadra n normele prescrise privind calitatea apei ,aerului, solului i
subsolului i cele referitoare la zona studiat a localitii Vlhia, unde se afl obiectivul.
n vederea ntocmirii acestei analize au fost consultate studiile de specialitate,
documentaiile i documentele referitoare la zona n care se afl obiectivul, datele existente
cu privire la factorii de mediu. Au fost prelevate i executate analize de laborator pentru
determinarea eficientei functionarii statiei de epurare, incadrarea parametrilor de emisii in
ape de suprafata , compararea cu valorile maxime admise prin Normativul NTPA 001/2005,
cat si Autorizatia de Gospodarire a apelor ,modul de evacuare si calitatea namolului din
statia de epurare , cat si mosul de valorificare a acestuia. Totodata sau studiat rezultatele
determinarilor parametrilor de evacuare a apelor uzate in perioada anului 2011-2012 din
documentele puse la dispozitie de operator .
Activitatea specific a Punctului de Lucru Vlhia este exploatarea, ntreinerea, i
asigurarea ficionrii a instalaiilor de captare, tratare i distribuire a apei potabile n baza
Protocolului de Predare-primire din 02 august 2010, ncheiat de catre Operatorul SC HARVIZ
SA cu proprietarul acestor sisteme hidroedilitare cu Consiliul Local Vlhia.
Activitatea desfurat
COD CAEN 4100 : Captarea, tratarea i distribuia apei
COD CAEN 9100 : Colectarea i tratarea apelor uzate
Captarea, tratarea i distribuia apei. Sistemul de alimentare cu ap potabil si
canalizare menajera a oraului Vlhia a fost dat n funciune n anii 1971-1972 conform
Proiect nr. 1040/1969 elaborat de ISPGC Bucureti. Lucrrile de construcii i montaj a
obiectivului (cele dou captri, staia de tratare, reele de aduciune i distribuie) au fost
executate de fostul TCI Braov. In prezent sistemul de alimentare cu ap potabil este
alctuit din captri de suprafa de pe prurile Vrghi i Zmeuri cu o capacitate medie
88

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

de 40l/s, care a fost modernizat si dezvoltat .In staia de tratare se executa tratarea,
decantarea si filtrarea apei. Apa tratat este distribuit ctre consumatori printr-o reea de
aduciune i distribuie cu diametre cuprinse ntre 125 i 250 mm, cu o lungime de cca
28,945 km. Pe traseul conductei s-au prevzut cmine cu regulatoare de presiune, cmine
cu debitmetre, cmine cu ventile de aerisire i traversri i subtraversri ale prului
Vrghi.Consumatori : populaie 12-22 l/sec, Populaie deservita 6.893 locuitori din total de
7.043 locuitori. , ageni economici 98 ( conform anexei )
Capacitai, volume, debite apa autorizate.Conform Autorizaiei de gospodrire a
apelor nr 274/31.01.2012
Emis de Administraia Naionala Apele Romane
Administraia Bazinal de APA OLT rezulta urmtoarele:
Oraul Vlhia este alimentat cu ap potabil din dou surse de suprafa i anume din
prul Vrghi i Zmeuri, cod cadastral VIII-1-67-7 , care izvorsc din versantul sudic al
masivului munii Harghita.Debitul instalat a celor dou captri sunt: pe prul Zmeuri 80
I/s, iar pe pr. Vrghi 70 I/s, dar cu un debit mediu prelevat de 40 I/s. Captrile sunt dotate
cu baraje de priz i camere de priz cu hidroelevator (sistem vertical) i camere de
aspiraie.Transportul apei de la cele dou captri se face prin conducte de aduciune de Dn
150 mm. Aduciunea Vrghi - staia de tratare este de 540 m iar Zmeuri staia de tratare
este 1540 m. Ambele aduciuni sunt prevzute cu debitmetre Parshall.Apele din cele dou
aduciuni se unesc ntr-un cmin de intersecie de unde sunt conduse la staia de tratare
printr-o conduct cu Dn 250 mm. Apa potabila livrata trebuie sa respecte condiiile de
calitate prevzute in STAS-ul 1342-91 si trebuie sa asigure prin analize corespunztoare
prescrise prin standarde respectarea acestor parametrii de calitate.
La staia de tratare se execut urmtoarele procedee:

tratarea apei cu lapte de var si sulfat de aluminiu, silicea la nevoie, ( tratare cu


reactivi) urmnd decantarea in decantoare verticale suspensionale.

filtrarea apei decantate n 4 filtre rapide cu o suprafa de 12 m2 fiecare.


Apa filtrat este depozitat n dou rezervoare de 500 m 3 fiecare.
Staia de tratare este dotat cu un laborator propriu de analiz a calitii apei.
Prezentarea Sistemelor de captare : Suprafata
VIII.1.67.7 . Pr Zmeuri Hm 14

: Pr Vrghi

Hm 100, cod cadastral

Debitul instalat a celor dou captri:


Sursa Vrghi : Q max Vrghi =

70 I/s.

Sursa Zmeuri : Q max pr. Zmeuri = 80 I/s,


Volum si debite de apa autorizate :

Q zi max = 4000 mc - 46 l/sec anual 1460 mii mc

Q zi med = 2500 mc - 29 l/sec anual 912,5 mii mc

Q zi min = 1500 mc 17,5 l/sec anual 550 mii mc


Regim de funcionare; permanenta 365 zile/a , 24 ore/zi
Instalaii de captare
Apa de Suprafa pr. Vrghi

2 camere de captare cu priz, deznisipator i camere de sedimentare pentru un


debit max. de 70 l/s

Prag de fund pentru ridicarea nivelului apei

Diguri submersibile pentru dirijarea apei ctre priza de captare

Priz orizontal pe talvegul rului

Apa de Suprafa pr. Zmeuri


89

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

2 camere de captare cu priz, deznisipator i camere de sedimentare pentru un


debit max. de 80 l/s

Prag de fund pentru ridicarea nivelului apei

Diguri submersibile pentru dirijarea apei ctre priza de captare


Instalaii de tratare:

La staia de tratare se trateaz apa de la cele dou captri desfurnd


urmtoarele procese de tratare:

tratarea cu lapte de var i sulfat de aluminiu n soluie i silice activ n cazul


temperaturilor sczute

decantare suspensional

filtrare cu filtre rapide

Procesele de tratare se desfoar ntr-o singur construcie alctuit din camera de


amestec,
decantoare suspensionale cu D=5,8m, 4 cuve de filtre rapide cu S=12mp fiecare,
rezervoare ap pentru splare filtre, rezervoare de nmagazinare 2x500mc.
Instalaia de aduciune i nmagazinare a apei

Transportul apei de la cele dou captri se face prin 2 aduciuni din PVC cu Dn =
250 mm i lungimea de L=1276m (de la captarea Zmeuri) respectiv cu Dn =
150 mm i lungimea de L=600m (de la captarea Vrghi), pn la cminul de
intersecie de unde apa este dirijat spre camera de amestec a staiei de tratare
printr-o conducta comun PVC cu DN250 mm L = 19,5 m.

Apa tratat este nmagazinat n 2 rezervoare de 500 mc fiecare.

Reeaua de distribuie a apei potabile .Apa tratat este distribuit ctre consumatori printr-o
reea de aduciune i distribuie cu diametre cuprinse ntre 125 i 250 mm, cu o lungime de
cca 28,945 km. Pe traseul conductei s-au prevzut cmine cu regulatoare de presiune,
cmine cu debitmetre, cmine cu ventile de aerisire i traversri i subtraversri ale
prului Vrghi.
Apa pentru stingerea incendiilor Volum intangibil: 500 mc.Debitul suplimentar acceptat
pentru refacerea rezervei de incendiu din surse 9,14 l/sec din prul vrghi i 5,9 l/s din
prul zmeuri.
Volume de ap asigurate din surse: pentru alimentarea cu ap a folosinei Surse de
suprafa:
Zilnic mediu 2500 mc 29 l/s anual 912,5 mii mc
Modul de folosire a apei .Necesarul total de ap: maxim 4000 m3/zi; mediu - 3000 m3/zi;
minim 1500 m3/zi.
Cerina total de ap: maxim 4000 m3/zi; mediu - 3000 m3/zi; minim 1500 m3/zi.
Conform diferitelor normative, indicatorii de calitate ai apei de but trebuie sa respecte
prevederile HG 458 /2002 cu modificarile si completarile ulterioare , prescrierile Autorizatiei
Sanitare , cat si Autorizatiei de Gospodarire a apelor
COLECTAREA

SI

TRATAREA

APELOR

UZATE

CANALIZAREA

MENAJERA

ORASENEASCA
Reeaua de canalizare Reea de canalizare: este realizat n sistem divizor. Reeaua de
canalizare este realizat din tuburi de beton, cu diametrul de 300 mm (n lungime de 1400
m) i 200 mm (n lungime de 3300 m). Lungimea total a reelei de canalizare este de circa
4.7 km i deservete 2,200 de locuitori, 7 instituii, 85 de uniti industriale i dou blocuri,
adic 34% din strzile pe care exist alimentare cu ap.
90

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Sistemul de colectare a apei uzate din Vlhia este separativ deservind n general zona
central a oraului respectiv strzile: Gabor Aron, Spitalului, Jozsef Attila, Teilor si cartierul
M. Eminescu.
Lungimea total a reelei de canalizare menajer este de 4,7 km, conducte din beton i
azbociment cu diametre de la 200 pn la 300mm.Reeaua existent deservete
aproximativ 2200 de locuitori, 7 instituii, 85 de uniti cu caracter industrial i dou blocuri.
Rata de conectare este de 27%.
Monitorizarea calitii apei uzate de-a lungul sistemului de canalizare se face prin
prelevarea de probe din cminele de racord a acestor ageni economici. Prelevarea se face
cu o frecven lunar. Parametrii de calitate analizai sunt: Materii .n suspensie, reziduu fix,
azot total, extractibile, detergeni, CCB5, CCOCr, iar procentul de analize conforme/an este
de 83%. Se pare ca de-a lungul reelei de canalizare exist zone n care, datorit strii
conductelor, apa freatic ptrunde n reea producnd diluia apei uzate la intrarea n staia
de epurare. Aceste zone, n prezent, nu pot fi determinate cu precizie din cauza lipsei de
aparatur adecvat. Pe viitor se va ncerca identificarea zonelor respective i poziionarea
pe hart, pentru investiii ulterioare. n acest moment singura monitorizare pe reeaua de
canalizare se face n cminele de racord a agenilor economici posibili poluatori. n cazul
unei poluri accidentale vor lua probe din emisar.
Staia de epurare:

Staia de epurare tip BNA cu stabilizarea nmolului cu o capacitate de 16 l/s.

Canal de msura din beton L = 11 m prevzut cu Camin de capt.

Grtar.

Bazin de aerare si decantare, construcie din beton armat cu dimensiunile de 17


x 16,60 x3,55 mc, prevzut cu jgheab central care se realizeaz accesul apelor
uzate menajere in bazin si doua jgheaburi marginale pentru ieirea apei
decantate.

Aerarea se realizeaz cu ajutorul a doua turbine cu 750 rot/min.

Nmolul depus in decantoare este evacuat prin sifonare prin 4 conducte in 4


cmine de nmol de unde este introdus in bazin de depozitare.

Din depozitul, nmolul este pompat cu o pompa ACV 80 la halda de zgura a


uzinei SC Metalurgica Vlhia SA.
n prezent se afl n faz de finalizare un proiect finanat prin OG7 pentru
dezvoltarea reelei de canalizare menajer.Executarea lucrrilor pe reeaua de
canalizare menajer in zonele centrale, de nord i nord est, vor soluiona n bun msur
problema pentru aceste cartiere. Extinderea reelei de canalizare n partea de sud dar i
ntregirea acesteia n celelalte zone, face parte din Proiectul POS Mediu.Materialele
predominante pentru conductele vechi de canalizare ap uzat sunt betonul i
azbocimentul. Pentru tronsoanele noi realizate s-a utilizat PVC.Pentru extinderile reelei de
canalizare n execuie sunt prevzute trei staii de pompare, amplasate pe strzile
Vntorilor, pentru zona de nord-est a oraului, trandului pentru zona central i Oratrand pentru zona median. Numrul total al conectrilor este 91, cu 45 pentru blocuri, 18
pentru case si 28 pentru unitile economice.15% din apa uzata colectata zilnic este
industriala. Dup realizarea extinderilor incluse n programul OG7, se vor aduga nc 285
de conectri pentru case.
Colectorul principal Dn 300 mm amplasat pe strada Gabor Aron este n mare parte avariat
fiind strpuns pe un tronson de peste 500 m de rdcinile arborilor din zon, fapt ce a
condus la creterea debitului infiltraiilor i la obturarea seciunii de curgere.
In conformitate cu Autorizaia de Gospodrire a apelor:
Debite caracteristice a apelor uzate evacuate in receptori naturali: pr. Homorodul Mic

Q zi max = 1400 mc/zi = 16,0 l/sec;

91

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Q zi med = 1300 mc/zi = 15,0 l/sec;

Anual 474,5 mii mc.

ORIGINAL
Pagina 1

Categoria apei: Ape uzate urbane


Indicatorii de calitate apelor
002/2005

uzate influente in stemul de canalizare: Conform NTPA

Indicatorii de calitate apelor uzate efluente i staia de epurare evacuate in pr. Homorodul
Mic
Categoria apei
Urbane
Emisar Homorodul Mare

Indicatorii de calitate
pH
Materii in suspensie
CBO5
CCOcr
Detergeni sintetici
Azot total
Reziduu filtrat la 105 oC
Subst. extr. cu solveni
organici

Valori
maxime
admise mg/l
6,5-8,5
120,0
150,0
250
2.0
30,0
1000
20,0

Tratarea apelor uzate - statia de epurare oraseneasca


Staia de epurare este de tip mecano - biologic i are capacitatea proiectat de 16 l/s, care
ns nu este de ajuns n momentul de fa, mai ales cnd partea nordic a oraului va fi
racordat la acest sistem. Este dotat cu debitmetru Parshall, - 1 bazin de aerare,- 2
aeratoare i pompe de nmol.Nmolul depus de la decantoare este scos prin sifonare prin 4
conducte in 4 cmine si din acestea prin gravitaie este introdus intr-un bazin de depozitare.
Din depozit nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a uzinei SC
Metalurgica SA, sau vidanjarea periodica sau transportarea acestora pe fnee.Evacuarea
apelor uzate se realizeaz n prul Homorodul Mic.Investiia a fost executata in anul
1972, dupa tehnologia de la ceea vreme , din echiparea staiei lipsind unele componente
eseniale pt o funcionare eficienta , iar la stabilirea parametrilor de evacuare sau luat in
calcul diluia dupa evacuare in Homorodul Mic ( conform D.C.S. 414/1979 ) fiind stabilite
valori relativ ridicate , ori prin apariia NTPA 001/1997 respectiv NTPA 001/2002,cat si
NTPA011, legislaia impune noi masuri de imbunatatirea a parametrilor de evacuare.Este
necesar de artat ca obiectivul o are o capacitate mult mai mica dect ceea ce este
necesar localitii in prezent, innd cont ca o mare parte a localitii nu este canalizata ,
totodat nu este rezolvata nici problema nmolului stabilizat.
Staia de epurare lucreaz la un randament sczut, in (comparnd analizele realizate, fata
de valorile NTPA 001/2005) aceste valori se situeaz n jurul valorii de 20-40 %, totodat nu
este rezolvat n cadrul staiei deznisiparea, degresarea, decantarea prealabil apelor uzate
influente, i dezinfectarea apelor epurate efluente, totodat prezint o problem i
evacuarea i depozitarea nmolului stabilizat.
Apele uzate efluente din staia de epurare au un coninut ridicat de Azot amoniacal, CBO5,
CCO cr fata de valorile admise prin Normativul sus amintit , dar in autorizaia de
Gospodrire a apelor nr 274/31.01.2012 innd cont de condiiile concrete din zona orasului
Vlhia sunt admise valori mai largi in aceasta perioada de realizare a dezvoltrii staiei de
epurare.
Schema tehnologica de epurare Schema de epurare folosita urmrete in mod special
reinerea materiilor in suspensie, a substanelor flotante, eliminarea substanelor
biodegradabile exprimate prin CBO5.
Obiectele tehnologice sunt comasate in trei grupuri
92

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

linia apei
linia nmolului
construcii si instalatii auxiliare

Fluxul tehnologic pe linia apei consta din:

grtar rar

debitmetru Parshal

camera de distribuie

bazin de aerare cuplat cu decantor secundar

canale si conducte de legtura


Fluxul tehnologic pe linia nmolului

concentrator de nmol

pompe de evacuare nmol

pompare finala a nmolului

conducte tehnologice de legtura


Faze tehnologice de lucru:

Prin epurarea mecanica are loc ndeprtarea in principal a materiilor in


suspensie si a substanelor separabile gravitaional, realizat cu ajutorul
grtarului de reinere. Materiile solide colectate se colecteaz in pube nchise si
se transporta pe platforma de deseuri menajere.

In bazinul de aerare, oxigenul necesar meninerii condiiilor vitale ale bacteriilor


din cadrul sistemului cu nmol activ este asigurat de instalaia de aerare
generat de sistemul de aerare cu turbine 2 x22 KW / se menioneaz eficienta
slaba a acestetui sistem de aerare ) . Apa menajera nmolul activ din spaiul
bazinului de aerare ajunge prin sistemul de distribuie central in decantorul
secundar , in care sunt reinute particulele foarte fine ce a ce duce la reducerea
particulelor in suspensie , In spaiul de aerare se introduce oxigenul necesar
desfasurarii proceselor biochimice pe o durata de 2-3 ore , in timp care se
realizeaz omogenizarea apei uzate, aerului cat si a nmolului activat, - proces
in care are loc reducerea substanelor organice biodegradabile si a amoniacului.
Nmolul in exces stabilizat aerob se depoziteaz in concentratorul de nmol
unde se compacta gravitaional

Nmolul depus de la decantoare este scos prin sifonare prin 4 conducte in 4


cmine si din acestea prin gravitaie este introdus intr-un bazin de depozitare.

Din depozit nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a
zonei SC Metalurgica SA ( iniial ) , sau vidanjat periodic

Evacuarea apelor uzate se realizeaz n prul Homorodul Mic.


Componente constructive
Treapta mecanica:

Grtare rare

debitmetru Parshall;
Treapta biologica:

bazine de aerare cuplat cu decantor secundar;

Concentrator de nmol;

Sistem de aerare cu turbine ( 2 x22 KW );

Staie pompare pentru nmol stabilizat;


93

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Anexe

Conducte si canale de incinta.

Laborator chimic pt analize;

Vestiar , grup sanitar;

ORIGINAL
Pagina 1

Atelier mecanic ,electric.


Debite caracteristice a apelor uzate colectate ce urmeaz a fi epurate reale

Q zi med = 638,6 mc/zi = 7,39 l/sec

Q zi max =734,4 mc/zi = 8,50 l/sec

Q or.max = 61,20 mc/h = 17,00 l/sec

Q or.min
= 6,39 mc/h = 1, 77 l/sec
Parametrii de evacuare stabilii prin NTPA 001 /2005 si NTPA 0011
Dup epurare apele uzate sunt evacuate n prul Homorodul Mic parametrii de emisie
trebuie sa se ncadreze n valorile maxime stabilitate prin NTPA 001/2005 si NTPA 011 care
impune urmtoarele incarcari maxime

pH
2012

suspensii max .

CBO5 max .

CCO Cr

substane extractibile n eter de petrol

azot amoniacal
( azot total )

fosfor total

detergeni sintetic biodegradabili

clor rezidual liber

temperatura

6,5-8,5
60 mg/l

Aviz Ga 274 /
120 mg/l

25 mg/l

150 mg/l

125 mg/l

250 mg/l

20 mg/l

20 mg/l

3,0 mg/l

30 mg/l

2,0 mg/l
1,0 mg/l
0,2 mg/l
max. 40 C

Gradul de epurare realizat


Din tabel anexa A , care prezint concentraii medii anuale a parametrilor influente si
efluente in staie de epurare pentru anul 2011, rezulta urmtoarele randamente de
reducere a noxelor in staia de epurare :

d CBO5

d CCO Cr

d susp.- nu sunt date

PH se ncadreaz in valori legale

cca. 21 %
cca. 19 %

Debit anual orar 16,51 l/s.


Disfuncionaliti existente la staia de epurare
Lipsa unor obiecte componente sau operaii de baza in vederea funcionarii normale a
staiei pentru obinerea unor randamente corespunztoare ca:

grtar fin sau decantorul primar;

deznisipator;

faza de denitrificare
94

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

separator de grsimi;

instalaie de dezinfectare pentru ape uzate epurate;

gospodria de nmol.

ORIGINAL
Pagina 1

Capacitate redusa a staiei de epurare , chiar pt faza actuala nelund in calcul


perspectiva de fi legat la canalizare si partea nordica localitii.
Totodat trebuie arat ca:

Nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial in


proiect duce la poluarea solului si a subsolului

In prezent nmolul nu este evacuat din cauza defectrii sistemului de si


transportat si este necesar vidanjarea acestuia. Este necesar ca aceasta faza,
operaie sa fie executat conform reglementarilor legale.

ncrcrile mari ale parametrilor de evacuare in unele perioade, datorita


neevacurii periodice a concentratorului de nmol din staia de pompare.

Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare , si ocazional realizate Goscom
Miercurea Ciuc . Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente si efluente in staie de epurare.
Fata de cele prezentate este necesar modernizarea staiei de epurare prin
retehnologizare reutilare, pt a obine randamentele prescrise, respectarea parametrilor de
evacuare cat si mrirea capacitaii staiei innd cont ca o mare parte a localitii inca nu
beneficiaz de sistem de canalizare
CONCLUZIILE BILANTULUI DE MEDIU NIVELUL I
n ceea ce privete factorii de impact asupra mediului a activitilor istorice i prezente
pentru amplasamentul studiat se pot constata urmtoarele:

nu s-au produs perturbri sau pierderi legate de folosirea terenurilor;

nu s-au produs afectarea surselor de alimentare cu ap potabil;

amplasamentul nu se afl n zon inundabil;

condiiile atmosferice naturale se caracterizeaz prin;


vnturi puternice,
micarea maselor de aer, condiii bune de dispersie a gazelor;

emisiile de poluani n aer ,de la unitatea studiat este redusa i nu au avut


efecte majore negative asupra sntii oamenilor, florei, faunei.

zona nu este caracterizat prin existena unor habitate sau ecosisteme


valoroase;

amplasamentul are o bun accesibilitate rutier;

Exploatarea instalaiilor de captare, tratarea si distribuirea apei se realizeaz in


concordanta cu autorizaia de gospodrire a apelor, Licena ANRSC, Autorizaie
sanitara de funcionare;

Respectarea zonelor de protectie sanitara pt captrile si instalatia de tratare

Staia tratare, ngrdit, personal de paza supraveghere pe tot timpul inclusiv la


sfrit de saptamana si srbtori legale;

Sigurana funcionarii .sistemului de alimentare este asigurata;

Urmrirea procesului tehnologic , prin laboratorul de analiza chimica este


asigurata;

Personal calificat pt Operatiile executate;


95

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Startarea instalatiior de tratare instalaiilor este corespunztoare;

Amplasamentul i activitile din zona adiacent pn-n prezent nu au provocat


controverse publice privind starea mediului;

Staia de epurare
Valorile medii ale principalilor parametrii ai apelor uzate, influente si efluente din staia de
epurare pe luni din cursul anului 2011 ( debit, CBO5, CCOcr) furnizat de beneficiar sunt
prezentate in tabelul anexat
Totodat sunt anexate buletinele de analiza privind principalii parametrii intrare-a esirea cu
valori momentane a parametrilor determinate executat , la solicitarea beneficiarului de
catre SC Goscom SA Miercurea
Din buletinele analiza rezulta ca staia de epurare lucreaz cu randamente sub cele
prevzute prin normativele mai sus amintite, datorita tehnologiei aplicate nvechite, a
uzurii instalaiilor, cat si nefuncionarea unor pari a instalaiilor. Pentru a atinge
performantele prescrise in normativele specificate impuse , este necesar procedeul de
epurare biologica cu faza de denitrificare a apelor uzate
Este de menionat faptul ca staia de epurare nu a fost dotat cu instalatii de tratare a
nmolului rezultat , fiind prevzut cu sistemul de pompare pe halda de zgura a SC
Metalurgica SA , care in unele perioade nu funcioneaz.
Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate in laboratorul chimic al staiei de epurare, si ocazional realizate Goscom
Miercurea Ciuc. Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente si efluente in staie de epurare.
Fata de cele prezentate este necesar modernizarea staiei de epurare prin
retehnologizare reutilare, pt a obine randamentele prescrise, respectarea parametrilor de
evacuare cat si mrirea capacitaii staiei innd cont ca o mare parte a localitii inca nu
beneficiaz de sistem de canalizare
In concluzie se poate arta c in baza probelor colectate din sol, analiza
deeurilor tehnologice, a msurtorilor si a analizelor fizico-chimice realizate in
timpul efecturii prezentului bilan de mediu, se va putea ntocmii bilanul de
mediu nivel II, in vederea stabilirii impactului asupra mediului prin activitatea
desfurat de Activitatea Captarea, tratarea si distribuirea apei, Respectiv
colectarea apelor uzate in oraul Vlhia, stabilirea unui proiect de program de
conformare, corespunztor obligaiilor de mediu in vederea ncadrrii in legislaia
actual de mediu.
DESCRIEREA SI REZULTATELE INVESTIGATIILOR
Investigaiile bilanului de mediu nivel II sunt cerute cnd se identific anticipat poluarea
unei zone sau cnd rezultatele bilanului de mediu nivel I ; indic o potenial poluare a
zonei i sunt necesare clarificri privind natura si intensitatea polurii identificate si trebuie
ntreprinse investigaii mai aprofundate pentru a se realiza o evaluare cantitativ a
nivelurilor de poluare din zona analizat. Tanant cont activitatea unitatii se rezuma in
special la colectarea si epurarea apelor uzate menajere si tip menajere din orasul Vlhia
investigatiile studiului se refera inspecial la verificarea incadrarii in normele legale privind
evacuarile de ape uzate epurate in apele de suprafata , cat si modul de gospodarire a
namolului rezultat din statia de epurare
Sursa principala a emisiilor de poluanti in apele de suprafata si subterane reprinta statia de
epurare a orasului Vlhia care datorita uzurii morale si fizice nu poate asigura randamente
corespunzatoare de epurare a apelor uzate menajere in condiile actuale . Schema
tehnologica de epurare folosita urmrete in mod special reinerea materiilor in suspensie,
a substanelor flotante, eliminarea substanelor biodegradabile exprimate prin CBO5.
96

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

POLUAREA APELOR DE SUPRAFATA SI SUBTERANE


Ape uzate tehnologice evacuate de la statia de epurare oras Vlhia
In tabelul alturat este prezentat, evoluia principalilor indicatori de impurificate a apelor
uzate evacuate din unitate, n baza automonitoringului,si determinri ulterioare solicitate
de elaboratorul Bilanului, determinrile fiind realizate de laboratorul S.C. GOSCOM S.A.
Miercurea Ciuc si SGA Miercurea Ciuc.
Din tabelul de mai sus se observ c:

n ceea ce privete pH ul apelor se constata ncadrarea in valorile admise

la parametrul CCO cr si CBO5 sunt depasiri fata de valorile admise atat in ce a


ce priveste valorile maxime prevazute atat fata de NTPA 001/2005 cat s
Autorizatia GA inspecial in perioada verii ;

La parametrul suspensii sunt depasiri fata de valorile admise atat in ce a ce


priveste valorile maxime prevazute atat fata de NTPA 001/2005 cat s Autorizatia
GA inspecial in perioada calda ;

La paramterul azot amoniacal se constata depasiri substantiala atat fata de


valorile NTPA 001/2005 si Autorizatie GA datarita faptului ca procesul biologic de
epurare are randamente foarte scazute procesul de denitrificare practic nu
exista ;

La parametrul substane extractibile se ncadreaz n valorile maxime admise.

Determinrile recente realizate arata ca concentraiile principalilor parametrii a poluantilor


n apele uzate evacuate din statia de epurare depesc valorile maxime admise in ape de
suprafata in conformitate cu prevederile NTPA 001/2005 i cele prevzute n Autorizatie
GA nr 274/20012 ,emis de ABA Olt
Unitatea are obligaia: s respecte parametrii de emisie a apelor uzate evacuate n apele de
suprafata , s se ncadreze n valorile maxime stabilitate prin Autorizatia GA emis de ABA
Olt
Rezultatele analizelor prezentate in tabelele si graficele de mai sus arata depasirea valorii
concentratiilor maxime admise atat fata de valorile NTPA 001/2005 cat si fata de
Autorizatia de gospodarire a apelor in cazul CCOcr, CBO5, suspensii, azot amoniacal , deci
trebuie urgentat realizarea cat mai urgenta a modernizarii statiei de epurare.
In problema calitatii apelor de suprafaa receptoare apelor uzate emise de la statia
de epurare se poate arata :
Conform datelor furnizate de Direcia Apelor, evaluarea calitatii rurilor si praielor, bazat
pe valorile caracteristice medii ale msurtorilor din anul 2011.
Dintre afluenii Oltului, pe prul Homorodul Mic in aval de oraul Vlhia, calitatea apei sa
incadrat in limitele clasei II att la grupa indicatori Regimul oxigenului cat si la grupa
Nutetrienti
ncadrarea seciunilor de supraveghere in categorii de calitate( in baza de msurtori )

Cursul de apa
chimic

Homorodul Mic

Seciunea
Aval Vlhia

Ordinul
II

Categoria de calit dpv fizico


Ro I,

GM I

TS D

Vrghi
Amonte Vlhia
II
RO I
GM I
TS *RO regim de oxigenare ,GM grad de mineralizare ,TS toxice si speciale ,TI toi
indicatorii

97

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

Este de mentionat faptul ca in cazul anotimpului secetos cand debitul paraului


este redus , ca si in vara anului 2012 , poluarea apelor paraului poate fi
semnificativa
POLUAREA SOLULUI
Principalul deseu rezultat in procesul de epurare a apelor uzate este namolul in exces care
trebuie periodic eliminat din spatiu de reactie ( din decantor) . In proiectul initial a fost
prevazut ca nmolul depus de la decantoare este scos prin sifonare prin 4 conducte in 4
cmine si din acestea prin gravitaie este introdus intr-un bazin de depozitare. Din depozit
nmolul este pompat cu o pompa tip ECV 80 la halda de zgura a zonei SC Metalurgica SA
( iniial ) , sau vidanjat periodic , unde va fi uscat si ulterior utilizat ca fertilizator pt
soluri .In nprezent acest sistem nu functioneaza din cauza unor defectarii instalatiilor de
transport namol fluid iar namolul in ultimul timp nu a fost evacuat din decantor astfel exista
o cantitate apreciabila acumulata . Namolul in suspensie odata cu functionarea sistemului
de aerare este poate efi evacuat cu apele epurate marind concentratia materialelor in
suspensie .Este important ca namolul sa fie evacuat conform procesului tehnologic stabilit ,
chiar si in cazul ca sistemul de evacuare prin pompare este defect
In cursul intocmirii bilantului de mediu Nivel II am considerat foarte important ca
sa determinam caracterul si eventual daca contine unele elemente toxice sau
periculoase pt care nu poate fi utilizat in agricultura, dupa deshidratare. In acest
sens
prin raportul de incercare nr 122153/12.11.2012
sa determinat,
caracteristicile fizice, componentele , chimice, continulutul de metale grele
toxice, PAH, PCB, astfel, ca in conformitate cu Ordinele MMGA 344 /2004 si
708/2004 MAPDR demonstrand ca poate fi utilizat in agricultura, dupa
deshidratare
Din activitatea desfurat pe amplasament n timpul funcionarii obiectivului rezult
urmtoarele tipuri de deeuri, codificate conform Catalogului European al Deeurilor:

nmoluri de la epurarea efluenilor proprii: 02 07 05;

reineri de la grtare, nisipuri, nmoluri de la epurarea apelor uzate municipale:


19 08 05.

Directiva 86/278/EC privind proecia mediului, n special a solului, atunci cnd se utilizeaz
nmoluri de epurare n agricultur, amendat de Directiva 91/692/CE i de Regulamentul
(CE) nr. 807/2003, transpus n legislaia naional prin O.M. nr. 344/ 2004 pentru aprobarea
Normelor tehnice privind protecia mediului i n special a solurilor, cnd se utilizeaz
nmolurile de epurare n agricultur.
Astfel , In cazul n care calitatea nmolului de la staia de epurare nu este pretabil folosirii
n agricultur, staia de epurare va trebui s gseasc alte modaliti de eliminare a
nmolului. Una dintre aceste posibiliti poate fi eliminarea nmolului din staii de epurare
de ape uzate menajer la depozitul de deeuri nepericuloase cu respectarea prevederilor
BAT-lui pentru depozite ( coninut de umiditate max. 65% i depunerea pe depozit
amestecat cu deeurile menajere n proporie 1:10)
Conform SR 13400, nmolurile provenite de la staiile de epurare oreneti dup treapta
de epurare biologic i fermentare, deshidratare de pe platformele de uscare sau instalaiile
mecanice de deshidratare cu o umiditate de 65%, se pot depozita numai n depozite
controlate. Oraul Vlhia nu are amenajat depozit de deeuri menajere controlate.
Nmolurile concentrate pot fi depuse prin pompare pe halda unitatii SC Metalurgica SA ,
amenajat , conform autorizatiei de gospodarire a apelor ,sau vidanjate transportate pe
fnei, dar in prezent instalatia este defecta. Reinerile de grtar, nmolurile brute,
deshidratate, trebuie ndeprtate din staia de epurare.
Nmolul format in statia de epurare va trebui sa fie evacuat , ori pe platforma de
dehidratare locala sau alte platforme de statii de epurare autorizate. Namolul din statia de
epurare Vlhia nu contine componente toxice si dupa deshidratare pot fi utilizate in
98

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

agricultura , conform leglementarilor legale.


Cantitatea total de materiale rezultate din procesul de epurare:

Nmol concentrat din staia de epurare cu coninut de substana uscata cca.


165 kg/zi s.u. cca62 to/an

Substane solide reinute pe grtare cca. 25 kg/zi 9 to/an colectat in conteiner


si depuse la halda de deseuri locale.

REZULTATELE DETERMINARII REALIZATE


Din datele prezentate rezulta ca namolul din statia de epurare al orasului Vlhia , nu
contine componente periculoase peste valorile maxime admise prin Ordinul MMGA nr
344/2004 , si deshidratat poate fi utilizat ca fertilizant in agricultura cu respectarea
conditiilor prescrise in normativul respectiv
Propunem ca namolul din decantorul statiei sa fie vidanjat si transportat la statia
de epurare Miercurea Ciuc si impreuna cu namolul de la amplasamentul respectiv
sa fie deshidratat si utilizat ca fertilizant , sau depus in depozit de deeuri
menajere
POLUAREA AERULUI
n cadrul staiei, epurare a apelor uzate se realizeaz prin metoda aerob, n aceast
situaie emisiile de poluanti i mirosuri sunt neglijabile, n cazul neasigurrii funcionrii la
parametrii proiectai, pot fi evacuate n atmosfer urmtoarele poluani a cror valoare
olfactiv (VO) prezint valori ridicate:

hidrogenul sulfurat, degaj un miros de ou stricat foarte puternic;

mercaptani ( metilmercaptan, etilmercaptan) elibereaz un miros de varz


stricat;

amoniacul prezint un miros neptor;

aminele ( metilamina, - prezint un miros de pete foarte pronunat;

acizi organici: acid acetic, acid butiric, acid valeric cu miros puternic i
neptor;

aldehid butiric cu miros rnced;

aldehid izovaleric cu miros neplcut de mr stricat.

Valoarea olfactiv ( VO ) reprezint raportul dintre tensiunea de vapori saturai a unei


substane i concentraia limit de percepere, se utilizeaz ca unitate de msur pentru
aprecierea cantitativ a mirosului.
Procedeele de tratare a nmolurilor sunt multiple i variate, fiecare obiectiv trebuie studiat
n condiiile sale specifice, documentaia prezentat trateaz prelucrarea nmolurilor prin
procedeul de prelucrare mecanic dinamic i paturi de deshidratare.
Principala surs de poluare pentru aer de pe amplasament reprezint noxele rezultate din ;
colectarea i depozitarea n condiii necorespunztoare a reinerilor de la grtare, din
fermentarea anaerob i aerob a nmolurilor rezultate din concentratorul de nmol i
depozitat in bazinul de nmol .
Conform reglementarilor legale concentraiile maxime a noxelor in aerul zonelor protejate
nu trebuie sa se depaseasca cele prevzute prin Legea nr 104/2011 si STAS 12574/1987,
iar pentru substanele nespecificate in acest document ele sa nu prezinte mirosuri olfactive
si persistente.
ncadrare in norme legale: Emisiile sub form de pulberi rezultate din ntreaga activitate
desfurat pe amplasament nu trebuie s depeasc 50 mg/mc la un debit masic de 0,5
99

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

kg/h, la o dimensiune a diametrului mediu al particulelor (dp) 5 nm, n conformitate cu


reglementrile legale : Ordin MAPPM nr 462/1993 .
Mirosuri Statie de epurare . In unele perioade , inspecial vara , exista mirosuri persistente
dezagreabile datorita nefuncionrii corespunztoare a procesului de epurare de aceea
este foarte urgent necesar retehnologizarea staiei de epurare.
In cursul realizarii bilantului de mediu nu am avut posibilitatea de a pune in evidenta
masurabila existenta mirosurilor . Dealtfel din consultarea vecinilor nu au fost sesizate
reclamatii in acest sens
Din cauza ca la statia de epurare emisii de poluanti sub forma de pulberi in suspensie sau
pulberi sedimentabile practic nu exista , nu sa considerat a se efectua analize in acest
sens.
CONCLUZII I RECOMANDRI
Oraul Vlhia este alimentat cu ap potabil din surse de suprafa, i anume din prurile
Vrghi i Zmeuri, care izvorsc din versantul sudic a masivului munii Harghita. Debitul
instalat a celor dou captri sunt: pe prul Zmeuri 80 l/s, iar pe prul Vrghi 70 l/s, dar
cu un debit mediu prelevat de 40 l/s. Captrile sunt dotate cu baraje de priz i camere de
priz cu hidroelevator (sistem vertical) i camere de aspiraie. Transportul apei de la cele
dou captri se face prin conducte de aduciune de Dn150 mm. Aduciunea Vrghi staia
de tratare este de 540m iar Zmeuri staia de tratare este 1540m. Ambele aduciuni sunt
prevzute cu debitmetre Parshall. Apele din cele dou aduciuni se unesc ntr-un cmin de
intersecie de unde sunt conduse la staia de tratare printr-o conduct cu Dn250 mm. La
staia de tratare se execut urmtoarele procese :tratarea apei cu lapte de var i sulfat de
aluminiu, silicea la nevoie(tratare cu reactivi) urmnd decantarea n decantoare verticale
suspensionale filtrarea apei decantate n 4 filtre rapide cu o suprafa de 12 m2 fiecare.
Apa filtrat este depozitat n dou rezervoare de 500 m3 fiecare. Apa potabil livrat
trebuie s respecte condiiile de calitate prevzute in STAS-ul 1342-91 i trebuie s asigure
prin analize corespunztoare prescrise prin standardele respectarea acestor parametrii de
calitate.
Staia de epurare
Valorile medii ale principalilor parametrii ai apelor uzate, influente i efluente din staia de
epurare pe luni din cursul anului 2011 (debit , CBO5, CCOCr) furnizat de beneficiar sunt
prezentate in tabelul anexat. Totodat sunt anexate buletinele de analiza privind principalii
parametrii intrare-a iesirea cu valori momentane a parametrilor determinate executat, la
solicitarea beneficiarului de ctre SC GOSCOM SA Miercurea Ciuc. Din buletinele analiza
rezulta ca staia de epurare lucreaz cu randamente sub cele prevzute prin normativele
mai sus amintite, datorit tehnologiei aplicate nvechite, a uzurii instalaiilor , cat i
nefuncionarea unor pari a instalaiilor. Pentru a atinge performantele prescrise n
normativele specificate impuse, este necesar procedeul de epurare biologica cu faza de
denitrificare a apelor uzate. Este de menionat faptul ca staia de epurare nu a fost dotat cu
instalaii de tratare a nmolului rezultat, fiind prevzut cu sistemul de pompare pe halda de
zgura a SC Metalurgica SA, care n unele perioade nu funcioneaz.
Disfuncionaliti existente la staia de epurare
Lipsa unor obiecte componente sau operaii de baza n vederea funcionrii normale a
staiei pentru obinerea unor randamente corespunztoare ca:

grtar fin sau decantorul primar

deznisipator

faza de denitrificare

separator de grsimi
100

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

ORIGINAL
Pagina 1

instalaie de dezinfectare pentru ape uzate epurate

gospodria de nmol

capacitate redusa a staiei de epurare, chiar pentru faza actuala nelund n


calcul perspectiva de fi legat la canalizare i partea nordic localitii

Totodat trebuie artat ca:

nmolul evacuat pe halda de steril al SC Metalurgica SA prevzut iniial n


proiect poate duce la poluarea solului i a subsolului n cazul unor deranjamente
privind funcionarea sistemului de transport

neevacuarea la timp a nmolului din staia de epurare duce funcionarea i mai


defectuoasa a staiei de epurare

n prezent nmolul nu poate fi pompat pe halda de zgura din cauza ca instalaia


este defecta eventual poate fi vidanjat periodic i transportat pe terenuri
agricole. Este necesar ca aceasta faza, operaie s fie executat conform
reglementrilor legale.

Principalii parametrii de evacuare a apelor uzate sunt monitorizai prin analize continue,
asigurate n laboratorul chimic al staiei de epurare, i ocazional realizate Goscom
Miercurea Ciuc. Sunt anexate buletine de analize ape uzate efectuate la SC Goscom SA
apelor uzate influente i efluente n staie de epurare.
n concluzie se poate arta c n baza datelor nregistrate privind parametrii de evacuare
din staia de epurare realizate att n laboratorul propriu i ce realizat de Goscom SA, ct i
cele realizate n timpul efecturii prezentului bilan se constata ca staia de epurare nu
poate asigura randamente corespunztoare n procesul de epurare a apelor uzate,
principalii parametrii de evacuare depasind valorile maxime admise.
Analiza deeurilor tehnologice, respectiv a nmolului din staia de epurare, rezulta ca
acesta nu conine componente periculoase, deci dup evacuare i deshidratare
corespunztoare poate fi utilizat n agricultura n conformitate cu prevederile Ordinul
comun M.M.G.A.nr.344/2004 i M.A.P.D.R. nr.708/2004 pentru aprobarea Normelor tehnice
privind protecia mediului i inspecial a solurilor cnd se utilizeaz nmolurile de epurare n
agricultur. Fata de cele prezentate este necesar modernizarea urgenta a staiei de
epurare prin retehnologizare reutilare, pentru a obine randamentele prescrise,
respectarea parametrilor de evacuare ct i mrirea capacitii staiei innd cont ca o mare
parte a localitii nc nu beneficiaz de sistem de canalizare.
PROPUNERI PENTRU PROGRAMUL DE CONFORMARE
Propuneri pt modernizarea statiei de epurare
Memoriu tehnic pentru modernizarea statiei de epurare cuprinde obiectele tehnologice din
cadru staiei de epurare Vlhia necesare pt functionarea normala a acestuia
Obiecte componente a statiei de epurare modernizate :

Bazin de primire a vidanjului;

Cmin deversor;

Grtar mecanic;

Staie de pompare;

Deznisipator aerat cuplat cu separator de grsimi;

Bazin de aerare prelungit i decantor secundar radial;


101

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Bazin de contact cu clorul;

Cmin debitmetru;

Concentrator de nmol;

Staie de preparare soluii chimice;

Staie de filtre deshidratare nmol;

Reele tehnologice interioare incint:

ORIGINAL
Pagina 1

Canal de ocolire staie epurare i pe perioada execuiei;


Conduct ap uzat menajer, ap epurat,
Conduct ape uzate tehnologice(supernatant, filtrat, etc);
Conduct nmol stabilizat;
Branament de ap potabil i incendiu;
Propuneri pt gospodarirea deseurilor
Pana la realizarea si punerea in functiune a investitiei de modernizare a statiei de epurare
Vlhia Operatorul are sarcina de a vidanja si transporta namolul din decantorul statiei la o
statie de epurare in vederea dehidratarii , in vederea utilizarii acestuia conform
reglementarilor legale , in cazul ca nu poate fi pusa in functiune sistemul de evacuare la
halda SC Metalurgica SA
Dupa realizarea investitiei namol va fi gospodarit conform tehnologiei prescrise , si
Autorizatie de Gospodarire a apelor.
Propuneri pt monitorizarea tehnologica
Operatorul are obligatia de a preleva probe si executa analize prin forte proprii si in
laboratoare atestate , calitatea apei potabile atat la punctele de captare , tratare si
distribuire , conform HG 458/2002 cu completari ulterioare , Autorizatia sanitara si
Autorizatie de Gospodarire a apelor
Operatorul va fi dotat cu aparatura necesar pentru controlul emisiilor de poluani in
mediu, supravegherea calitii factorilor de mediu si monitorizarea activitilor destinate
proteciei mediului.Debitmetrul electromagnetic instalat n staia de epurare msoar
debitul de ap uzat pe fiecare linie de pompare. Citirea acestuia se poate face fie local pe
displai, fie centralizat din calculatorul de proces (opional). Acest obiect tehnologic este
amplasat amonte de modulul biologic de epurare, rezultnd o eviden precis a debitelor
de ap uzat epurat.
Se va urmrii prin analize in conformitate cu prescripiile normativului NTPA 001, NTPA 002
i NTPA 011, principalii ncrcri maxime influente si efluente in staia de epurare:

pH ; uniti pH

Materii n suspensie mg/dm3

Consum biochimic de oxigen la 5 zile (CBO5) mg O2/dm3

Consum chimic de oxigen - metoda cu mg O2/dm3

Azot amoniacal (NH4+) mg/dm3

Azot total

Fosfor total (P) mg/dm3

Substane extractibile cu solveni organici mg/dm3

Detergeni sintetici biodegradabili mg/dm3


102

TOTAL PROIECT SRL


ODORHEIU SECUIESC

RAPORT LA BILANUL DE MEDIU NIVEL I SI II PENTRU CAPTAREA


TRATAREA SI DISTRIBUIREA APEI, RESPECTIV COLECTAREA SI TRATAREA
APELOR UZATE IN ORASUL VLHIA JUD HARGHITA

Unitatea va tine evidenta deeurilor produse


856/2002.

ORIGINAL
Pagina 1

in conformitate cu prevederile HGR nr.

Bilantul de mediu a fost intocmit in cursul anului 2012 in conditiile functionarii obiectivelor,
captarea, tratarea si distribuirea apei potabile , cat si a statiei de epurare Vlhia

SC TOTAL PROIECT SRL

103

S-ar putea să vă placă și