Sunteți pe pagina 1din 4

ERROR-CHECK

1)CLASH CHECK
2)DATA CONSISTENCY CHECK
DATA CONSISTENCY CHECK
UTILITIES-DATA CONSISTENCY (BE ON PIPE)
CH CE (BE ON PIPE)--COMMAND

1)D400 ARRIVE TUBE LESSTHAN TUBE MINIMUM,ACTUAL TUBE LENGTH IS 21mm


DRAWBACKS: FABRICATION IS DIFFICULT
r)

(Reduce the SPOOL length & CHeck the erro

2) A 10 HEAD REFERENCE NOT SET


(Make the TAIL connect to LAST MEMBER n c
heck the error)
B 10 TAIL REFERENCE NOT SET
REASON : HEAD/TAIL IS CONNECTED TO NOTHING
DRAWBACKS: INCOMPLETE ISOMETRIC
CHANGES IN fgb IN ISO
3) D410 BAD ARRIVE GEOMETRY
)

(Add additional GASKET n check the error

REASON : HIERARCHY IS NOT FOLLOWED( modIFY-hier -reorder) (Create TEE for any i
nstrument before the flange n move after)
SMALL OVERLAP IN A LINE
EXTRA COMPONENT IN A LINE
DRAWBACKS: MAJOR ERROR ISOMETRIC IS NOT CLEAR(iso fail)
& problems in site....
MARK WITH 'ABC' ALL GASK FOR BRAN

(2see invisiible compo)

4) D430 BAD ARRIVE CONNECTION TYPE


D610 LEAVE CONNECTION TYPE NOT COMPATIBLE WITH CONNECTION

REASON: REQUIRED COMPONENT MISSING


EXTRA COMPONENT IN A LINE
END CONNECTIONS ARE NOT COMPATIBLE(EITHER IN RATING OR IN CONNECTION)
SWM - SWF
SCM - SCF

5)

A210 POSITION HPOS NOT SAME AS TERMINAL POSITION

REASON; BRANCH IS NOT IN NETWORK WITH HEADER


A410 HCONN NOT COMPATIBLE WITH CONNECTION TYPE OF HSTUBE

CLASH CHECK

UTILITIES ------CLASHES----CONTROL----CHECK CE (BE ON PIPE)

1)HH --- REAL CLASH BETWEEN ELEMENTS--(CHANGE ROUTING)


2)HS ----CLASH WITH OBSTRUCTION OR MAINTAINENCE OR OPERATING SPACE
E DECISION)
3)SS---- CLASH WITH FIRE FIGTHING SPACE(IGNORE)

ISOMETRIC EXTRACTION.....

UTILITIES - PIPE ISOMETRICS--(TEMPERORY METHOD)

LOGIN TO ISODRAFT MODULE


USER NAME -SAMPLE
PASSWORD- SAMPLE
COPY THE PIPE NAME FROM DESIGN
PASTE IN THE ISODRAFT MEMBERS & ENTER
TOOLS -----ISOMETRICS -STANDARD
BASIC.MET--MM
BASIC.IMP---FT & INCHES

SPLITTING OF ISO

(TAK

SELECT An COMPONENT (WHERE TO SPLIT IN DESIGN)


CREATE An ATTACHMENT
ATTY XXXX(COMMAND)
SAVEWORK IN DESIGN
GETWORK IN ISODRAFT
TOOL -----ISOMETRICS -STANDARD

ASSIGNING FLOW ARROW


SELECT An COMPONENT (WHERE TO ASSIGN FLOW ARROW)
CREATE An ATTACHMENT
ATTY FLOW(COMMAND)
SAVEWORK IN DESIGN
GETWORK IN ISODRAFT
TO TRANSFER FILES
LOG IN WITH ISODRAFT USERNAME-SYSTEM & P/W = XXXXXX
OPTION--MODIFY-- BASIC .MET--ADMINISTRATIVE
FORMAT--DIRECTORY--FILENAME---OK

(ONLY CHANGE)

AGAIN ENTER TO ISODRAFT WITH SAMPLE & CHECK

Commands for piping


Q HREF TREF( BE ON BRANCH)
Q HPOS TPOS
Q HCONN TCONN
Q HBORE TBORE
Q P1P2
axes at ph
axes at pt
Q P1P2P3
MARK CE
UNMARK ALL
Q CLLE
Q TULE
Q ATLE ( ARRIVE TUBE LENGTH)
Q LTLE ( LEAVE TUBE LENGTH)

(To check the length of Piping)


(To check the length of Pipe)

CHOO ALL
Q LASTMOD
Q USERMOD
CLAIM CE HIER
UNCLAIM ALL
Q PL BOP WRT/*
Q PA BOP WRT/*
Q PH
Q PT
Q NOFF OF BLTR OF SPREF
mtoc off
ADD ALL PIPE WITHIN VOL CE
ADD ALL PIPE WITHIN VOL CE 1000
Q ISPEC
ISPEC/K
STRUCTURES
Q
Q
Q
Q
Q
Q
Q
Q

SPREF
CUTL
DERLEN
NETWEI
DRNS
DRNE
BANG
MATREF GR275

(To hold any component in Material take off)