Sunteți pe pagina 1din 189

Pump Sound and Vibration

Single and two stage, end suction and axially split volute
type centrifugal pumps
FPD-1127 10-06

REFERENCE
MANUAL

Pumps
Sound and Vibration
CONTENTS

Page

Page

SOUND

APPENDIX I Detailed Sound Level


Information
- Durco ANSI & ISO Pumps

Quick Guide to Product Sound


Levels

Detailed Sound Level Information

Sound Level Addition

Durco Self-Priming Pumps

61

Sound Power Level

ANSI Lo-Flo Pumps

75

Octave Band Levels

ANSI Vertical In-Line Pumps 84

Estimate of Octave Band Level from


Overall dBA

Table I

Table II

VIBRATION
Vibration Severity Levels

Applicable Standards

Vibration Levels for Products

Durco ANSI Standard Pumps

Recessed Impeller Pumps

105

ANSI & ISO Non-metallic


Mechanically Sealled
Pumps

114

ANSI & ISO Non-metallic


Magnetic drive Pumps

139

Chemstar ISO Pumps

161

Informative Notes:
Peak Overall Vibration

Peak-to-Peak Overall Vibration

Peak-to-Peak Overall Displacement

Test v Site Values/Limits

Filtered (Discrete) Frequencies

Balance Grades

Page: 1

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration
SOUND
Quick Guide to Product Sound Levels

We may be required to provide sound levels


for our products so that users can assess their
plant noise levels and consider the effect of
exposure to noise for their employees, or in
some countries it is a legal obligation for
manufacturers to state the product noise level.
In many cases it is simply necessary to check
that a customer specification is met or to
provide the information as a CE Marking
requirement. In this case a general guide,
which can be used for all pumps covered by
this reference manual, is appropriate. This is
available in Table l, for pumps on their own
and with electric motors.
Sound level is dependent on a number of
operational factors, flow rate, pipework design
and acoustic characteristics of the building,
and so the values given are subject to a 3dBA
tolerance and cannot be guaranteed.
Within this tolerance, the values can be
applied to centrifugal pumps directly driven by
standard and high efficiency induction motors
when on load. Note that a motor driven by an
inverter may show an increased noise at some
speeds. If the motor has some special feature,
or a different type of driver is used, then its
specific sound level should be added to the
pump sound level to find the overall level. Also
where there are contract noise levels to meet
for an enquiry, then a more accurate estimate
will be obtained by using the actual motor
level.
Detailed Sound Level Information

Sound Level Addition

To add two sound levels together, e.g. Pump


only to Motor only, first convert them from
logarithmic to numerical values and add
together the numerical amounts, then convert
them back to the logarithmic value:
LpA

total=

10*Log((10^(LpA

pump/10)

+ 10^(LpA

motor/10))

Or use the following:


If the difference between
the two LpA values to be
added is:

______________________
0 to 1 dB
2 to 3 dB
4 to 9 dB
> 10 dB

then add this to


the higher value
to give the total:
______________
3 dB
2 dB
1 dB
0 dB

Sound Power Level

When sound pressure level LpA is above 85


dBA it is a requirement in some countries to
also provide the Sound Power Level LwA.
For estimating sound power level LwA (re 1pW),
the calculation is dependent on machine size,
but an approximation is to add 14 dBA to the
sound pressure value, for end suction
pump/motor sets, e.g. Durco Mark 3, and 17
dBA for axially split case pump sets e.g. LNN.
The sound power adder is calculated from:
10*Log10(S/So)

So = reference

area of 1m2

For information, an example detailed


calculation is also shown in Table IV.
Octave Band Levels

Some product series e.g. Durco ANSI and ISO


ranges have data available for all pump sizes,
speeds, impeller diameters and flow rates.
This information is provided in Appendix I. This
information would be used to obtain a more
accurate estimate for a specific pump duty.
The sound level for the actual selected motor
would also be used in this case.

Octave band levels may be presented as


linear dB values or weighted dB values,
usually to the A scale. If they are A weighted'
then the sound levels in the octave bands have
been adjusted to represent the response of the
human ear to different frequencies. In both
cases the overall dBA value is the same.

The values are in sound pressure level LpA at 1


m (3.3ft) from the machine, for free field
conditions over a reflecting plane.

If sound levels are required to the quoted for


octave bands, then pump and driver sound
levels should be separately determined and
then added in the usual way for each octave
band. (See above for addition procedure).

Page: 2

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration

It is clearly important to have the octave band


level for the pump and for the motor in a
consistent form i.e. both linear or both A
weighted.
The Durco range has octave band figures
presented in A weighted form. Appendix I.
If the motor values, to which the pump is to be
added. are in linear form, then one of set
numbers must be converted.
Table ll Line 1, lists the adjustment to be
applied to each octave band, to convert linear
octave band levels to A weighted,
Once the values are in the same form they are
added for each octave band separately using
the procedure in Sound level addition.
An example is shown in Table III, which in this
particular example has octave band levels A
weighted.
If the conversion is from A weighted to linear
then the adjustment is subtracted not added,
- again noting the sign.
Estimation of Octave Band Level from
overall dBA
If the detailed sound data for the pump is not
available then the pump-only octave band level
can be estimated from the Table II, Lines 2 or
3 as applicable by subtracting the value shown
for each octave band from the dBA value. The
correction is given for both A weighted and
linear values.
When the octave band level is stated to the
customer, it should be defined as being A
weighted or Linear.
The octave band noise level calculation can be
made to both sound pressure level LpA and
sound power level LwA.
Making an octave band calculation from the
combined pump and motor overall dBA value
is generally not sufficiently accurate.

Page: 3

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration
Table I

Typical sound pressure level, dBA, LpADWPUHIHUHQFH 3D


3500 r/min

Motor size
and speed

2900 r/min

1750 r/min

1450 r/min

Pump

Pump and

Pump

Max Pump

Pump

Pump and

Pump

Max Pump

only

motor

only

& motor

only

motor

only

& motor

dBA

dBA

dBA

dBA

dBA

dBA

dBA

dBA

<0.55 (<0.75)

72

72

64

65

62

64

62

64

0.75 (1)

72

72

64

66

62

64

62

64

1.1 (1.5)

74

74

66

67

64

64

62

63

1.5 (2)

74

74

66

71

64

64

62

63

2.2 (3)

75

76

68

72

65

66

63

64

3 (4)

75

76

70

73

65

66

63

64

4 (5)

75

76

71

73

65

66

63

64

5.5 (7.5)

76

77

72

75

66

67

64

65

7.5 (10)

76

77

72

75

66

67

64

65

11 (15)

80

81

76

78

70

71

68

69

15 (20)

80

81

76

78

70

71

68

69

18.5 (25)

81

81

77

78

71

71

69

71

22 (30)

81

81

77

79

71

71

69

71

30 (40)

83

83

79

81

73

73

71

73

37 (50)

83

83

79

81

73

73

71

73

45 (60)

86

86

82

84

76

76

74

76

55 (75)

86

86

82

84

76

76

74

76

75 (100)

87

87

83

85

77

77

75

77

90 (120)

87

88

83

85

77

78

75

78

110 (150)

89

90

85

87

79

80

77

80

132(175)

89

90

85

87

79

80

77

80

150 (200)

89

90

85

87

79

80

77

80

160(215)

(1)

(1)

(1)

(1)

83

84

81

83

200 (270)

(1)

(1)

(1)

(1)

85

87

83

85

250(335)

(1)

(1)

(1)

(1)

kW (hp)

300(400)

86

89

84

86

87

90

85

86

315(422)

87

90

85

86

355(475)

87

90

86

87
(1)

500(670)

88

(1)

86

1000(1300)

90

(1)

88

(1)

1500(2000)

90

(1)

90

(1)

(1) Noise levels of machines in this range should be based on actual equipment selected
For 1180 and 960 r/min reduce the 1450 r/min values by 2dBA
For 880 and 720 r/min reduce the 1450 r/min values by 3dBA
Table II

Line 1

Line 2
Line 3

Octave band mid frequency Hz

31.5

63

125

250

500

1K

2K

4K

8K

To correct linear values to A Weighted


add these values to the linear number,
noting the sign

-37

-26

-16

-9

-3

+1

+1

-1

48

33

23

15

16

11

10

15

For an approximation of octave band


values in A weighted form subtract
these values from the overall dBA value
For an approximation of octave band
values in Linear form subtract these
values from the overall dBA value

Page: 4

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration

Table III Example with job specific motor data

EXAMPLE: A Pump only at 2900 r/min 11


kW from Table I dBA value is 76 dBA
Corrections to put this into Octave band
figures A Weighted format
Resulting Octave band figures in A
Weighted format
JOB MOTOR: FPD Choice 11 kW motor
(equivalent data direct from motor
manufacturer) with motor overall dBA
value 69
Difference between pump and motor at
each Octave (both in same weighting
format)
RESULT: Pump + Job Motor gives 77 dBA
overall. Values are also worked out for
each Octave band.

76-48=28

76-33=43

76-23=53

76-15=61

76-8=68

76-6=70

76-5=71

76-9=67

76-16=60

28

43

53

61

68

70

71

67

60

27

29

31

51

57

59

68

60

54

28-27=1

43-29=14

53-31=22

61-51=10

68-57=11

70-59=11

71-68=3

67-60=7

60-54=6

31

43

53

61

68

70

73

68

61

Table IV Example detailed Sound Power


calculation for a specific job
A large 0.8 megawatt LNN pump and driver set has
a combined overall sound pressure level of 93 dBA
and the set has the following dimensions:
Length(L)
Width (W)
Height (H)

= 2.6 m
=1m
= 1.3 m

10*Log10(S/So)
So = the reference area always to use is 1m

S = 2LH+2WH+8H+4W+4L+WL+12 = 48.76 m

Hence sound power adder = 10*Log10(48.76) = 16.9

Hence the set sound power is 93 + 16.9 = 110 dBA


(re 1pW)

Page: 5

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration
Hydraulic Institute (HI)

VIBRATION
Vibration Severity Levels

The estimated overall vibration severity level


(unfiltered) is what Flowserve permits for the
specific product considering the specific
conditions of use such as the power, duty
point, normal and rated conditions, suction
margin, the condition of balance for rotating
components and the standard of installation.
Applicable Standards

A client may ask for one of the following:

The limit is when installed at site and is power


dependant increasing from 3 to 4.5 mm/s
RMS:
 4.5 mm/s RMS (above 75 kW)
 4.3 mm/s RMS (55 kW)
 4.2 mm/s RMS (45 kW)
 3.9 mm/s RMS (30 kW)
 3.7 mm/s RMS (22 kW)
 3.4 mm/s RMS (15 kW)
 3.2 mm/s RMS (11 kW)
 3 mm/s RMS (up to 7.5 kW)
Vibration Levels for Products

ISO 13709 / API610

Vertically suspended immersed pumps Limit


e.g. CPXV:
 5 mm/s RMS (inside 70-120% BEP)
 6.5 mm/s RMS (outside 70-120% BEP)
Limit for other types e.g. CPX, LNNV:
 3 mm/s RMS (inside 70-120% BEP)
 3.9 mm/s RMS (outside 70-120% BEP)
ISO 10816 Boundary Limit

These come from the older BS or VDA limits


which these supersede and apply to rigid
support conditions and Zone Boundary B/C.
Note that 1 or 2 vane clog-less/trash
handling impellers can have increased limits.
Limit for multi-vane impeller pumps with
separate driver
 4.5 mm/s RMS
Limit for multi-vane impeller pumps with
special integral drivers
 2.8 mm/s RMS

To check if the Product can comply with the


applicable standard use Graph I together with
the applicable Product operating point factor.
It is important to check the conditions of use,
which follow, are satisfied.
Conditions for use

Pumps have fully grouted in baseplates


Measured on the pump bearing housing
except LNNV, LRV et al where measured
at the drive end motor flange
Limit of inlet tip peripheral speed 20m/s
Impeller peripheral speed <60m/s and if
satisfied < 3500r/min
Good suction conditions: NPSHa>1.5 x
NPSHr
Pump has a rolling element bearing
Fixed speed normal balance electric
motor drive.
Impeller balance < G6.3 and normal motor
balance. With R (reduced) balance motors
and G2.5 pump rotor balance multiply
above Flowserve adjustment values by
0.7

Graph I

Page: 6

Type: Pumps

Issue: 10-06

Pumps
Sound and Vibration

50% to minimum
70-110% Best efficiency 50-70% and 110-120%
flow (BEP)
Best efficiency flow (BEP) continuous flow (MCSF)

Pump Type factor for Graph I


LNN, LNE, LR, LNNC et al

1.00

1.25

1.50

CPX, ISO PolyChem, CPXVet al#

1.00

1.20

1.35

LNNV, LNEV, LRV et al*

1.15

1.40

1.70

# Durco ANSI ranges complies with HI 2000 in the

preferred range
* Close-coupled versions only without cardan shaft

Informative Notes:
Peak Overall Vibration

The standards do not require peak overall


values (zero to peak), but if a client specifically
requires peak values multiply the rms severity
by 1.4 i.e. by (2)^0.5.
Peak-to-Peak Overall Vibration

If a client specifically requires peak to peak


rather than rms severity multiply the rms
severity by 2.8 i.e. by 2(2)^0.5.
Peak-to-Peak Overall Displacement

If a client specifically requires peak to peak


displacement refer to Engineering.
Test v Site Values/Limits

Unlike standards like ISO 13709 / API610, the


Hydraulic Institute standard recognizes that
temporary test rigs suffer higher levels of
vibration and up to twice that of a permanently
installed and grouted in pump set. While ISO
standards are beginning to recognize a
difference any allowance is less generous. For
example if a client specifies ISO 10816 Zone
Boundary B/C limit for a pump set between
15kW and 50MW, but without integral mounted
driver onto the pump, then the limit where rigid
is 4.5 mm/s RMS and the equivalent ISO
10816 Zone Boundary B/C limit where flexible
is 7.1 mm/s RMS. Many clients requesting ISO
10816 Zone Boundary B/C therefore tend to
accept up to 7.1 mm/s RMS on test provided
the set is offered to meet 4.5 mm/s RMS when
finally grouted in at site.
Filtered (Discrete) Frequencies

ISO 13709 / API610 requires additional Fast


Fourier Transform (FFT) tests to determine
Discrete frequencies in the range 5-1000 Hz or
if a very large number of impeller vanes the
1000 Hz is replaced by 2 x Number of vanes x
Running Speed Hz.

Page: 7

Type: Pumps

It is also required to assess the acceptability of


all discretes against the following limits:
The limitation in ISO 13709 / API610 for
individual frequencies is:
Horizontal units:
70-120% BEP < 2.0 mm/s
outside of the preferred range the limit on
individual frequencies is < 2.6 mm/s
Vertically suspended and immersed units:
70-120% BEP < 3.35 mm/s
outside of the preferred range the limit on
individual frequencies is < 4.36 mm/s
If ISO 13709 / API610 vibration severity
applies on a contract, and the FFT test is
specifically contracted, then the limitations on
individual frequencies apply and can be met.
Because of the above, this is a very expensive
test; when it is feasible to do so offer the client
the option of only having this type of test done
at the pump duty flow rather than 5 flows which
is the default in ISO 13709 / API610.
Balance Grades

Low rotating out of balance, such as at the


impeller, coupling and motor are important to
achieving low vibration. ISO 1940 grade G6.3
is where the permissible residue unbalance
and service speed equals 6.3 mm/s. Likewise,
grade G2.5 is where the permissible residue
unbalance and service speed equals 2.5
mm/s. G2.5 may be appropriate where the
lowest vibration levels are called for,
particularly on larger or vertical pump
configurations.

Issue: 10-06

Pumps
Sound and Vibration

APPENDIX I Detailed Sound Level

Information Durco ANSI & ISO Pumps

Sound level data based on test information is


available for most Durco pump sizes and for
different speeds, impeller diameters and flow
rates.
Where certain Durco pump sizes have not
been tested the following approximations may
be made.
Mark 3 ANSI standard horizontal pumps:
Use 10x8-16H data for the10x8-16.
Use 3x2-10 (Mark II) data for the 3x2-10A.
Mark 3 ANSI self-priming pumps:
Use 4x3US-13 data for the 4x3US-10H.
Mark 3 ANSI Sealmatic, Guardian (including
ISO Chemstar MD), F-pumps, T-Line and Epumps:
Use the equivalent size standard horizontal
Mark 3 ANSI pump data.
Chemstar ISO horizontal pumps:
In the case of all unlisted Chemstar pumps,
round up to the next larger casing diameter
(i.e. 200mm casing size rounds to 250mm).
Please note that these substitutions are for
estimates only.

Page: 8

Type: Pumps

Issue: 10-06

Durco B73.1 metallic sealed horizontal pumps


and
Durco B73.3 metallic sealless horizontal pumps
(Guardian)

50 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1-6

2/10/1999

Flow
3
m /hr
0
23
31

Total
Unfiltered
dBA SPL
64
67
72

63
43
44
44

125
46
48
47

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
55
47
59
58
56
51
57
61
62
62
52
60
67
67
64

8K
48
55
57

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5 in

3
m /hr
0
9
18
26

dBA SPL
67
69
67
70

63
42
42
42
41

125
44
42
43
43

250
54
53
52
54

500
64
63
59
63

1K
59
66
60
64

2K
59
61
62
65

4K
55
59
59
63

8K
49
53
55
55

RPM
3000

Imp. Dia.
3.5 in

3
m /hr
0
7
11
15

dBA SPL
65
65
65
65

63
44
44
44
43

125
45
45
44
45

250
56
53
52
53

500
60
59
59
59

1K
60
59
59
59

2K
58
60
60
60

4K
55
56
57
57

8K
47
48
49
50

RPM
1500

Imp. Dia.
6 in

3
m /hr
0
11
14

dBA SPL
63
62
62

63
41
40
43

125
48
48
49

250
51
49
50

500
53
53
53

1K
58
58
57

2K
58
58
57

4K
50
51
51

8K
40
40
40

RPM
1500

Imp. Dia.
5 in

3
m /hr
0
7
10
13

dBA SPL
62
63
62
62

63
40
38
37
38

125
44
43
43
43

250
49
49
48
49

500
52
52
52
54

1K
58
58
57
57

2K
58
59
58
58

4K
52
53
53
52

8K
39
39
40
40

10

60 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1-6

2/10/1999

Flow
gpm
0
100
135

Total
Unfiltered
dBA SPL
68
71
76

63
47
48
48

125
50
52
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
59
51
63
62
60
55
61
65
66
66
56
64
71
71
68

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5 in

gpm
0
40
80
113

dBA SPL
71
73
71
74

63
46
46
46
45

125
48
46
47
47

250
58
57
56
58

500
68
67
63
67

1K
63
70
64
68

2K
63
65
66
69

4K
59
63
63
67

8K
53
57
59
59

RPM
3600

Imp. Dia.
3.5 in

gpm
0
30
50
66

dBA SPL
69
69
69
69

63
48
48
48
47

125
49
49
48
49

250
60
57
56
57

500
64
63
63
63

1K
64
63
63
63

2K
62
64
64
64

4K
59
60
61
61

8K
51
52
53
54

RPM
1800

Imp. Dia.
6 in

gpm
0
50
60

dBA SPL
65
64
64

63
43
42
45

125
50
50
51

250
53
51
52

500
55
55
55

1K
60
60
59

2K
60
60
59

4K
52
53
53

8K
42
42
42

RPM
1800

Imp. Dia.
5 in

gpm
0
30
45
56

dBA SPL
64
65
64
64

63
42
40
39
40

125
46
45
45
45

250
51
51
50
51

500
54
54
54
56

1K
60
60
59
59

2K
60
61
60
60

4K
54
55
55
54

8K
41
41
42
42

11

8K
52
59
61

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-6

2/10/1999

Flow
3
m /hr
2
11
23
34
46

Total
Unfiltered
dBA SPL
92
77
72
71
72

63
59
42
42
42
43

125
69
45
45
45
46

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
83
85
86
86
63
64
70
73
70
60
63
68
64
65
58
63
68
64
62
58
63
68
67
62

8K
85
62
58
55
55

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5 in

m /hr
0
9
18
27
36

dBA SPL
66
68
68
69
69

63
45
44
44
44
45

125
44
46
46
46
47

250
54
54
54
55
56

500
59
59
59
61
63

1K
60
63
63
63
64

2K
60
63
64
64
64

4K
57
59
58
58
58

8K
52
52
54
54
53

RPM
3000

Imp. Dia.
4 in

3
m /hr
0
5
9
16
23

dBA SPL
66
67
68
69
68

63
42
45
45
45
45

125
44
46
46
45
46

250
56
56
55
55
56

500
60
61
61
61
60

1K
60
61
61
63
62

2K
60
61
63
65
64

4K
53
57
58
58
58

8K
47
51
53
53
52

RPM
1500

Imp. Dia.
6 in

3
m /hr
2
11

dBA SPL
67
65

63
39
39

125
48
48

250
53
53

500
58
59

1K
58
59

2K
63
60

4K
60
53

8K
50
45

23

64

39

46

52

57

59

60

53

44

3
m /hr
0
7
14
17

dBA SPL
64
64
64
63

63
41
41
42
42

125
48
48
47
48

250
55
55
54
55

500
57
58
57
57

1K
58
58
58
58

2K
58
58
58
57

4K
51
51
52
51

8K
38
40
40
40

RPM
1500

Imp. Dia.
5 in

12

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-6

2/10/1999

Flow
gpm
10
50
100
150
200

Total
Unfiltered
dBA SPL
96
81
76
75
76

63
63
46
46
46
47

125
73
49
49
49
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
81
87
89
90
90
67
68
74
77
74
64
67
72
68
69
62
67
72
68
66
62
67
72
71
66

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5 in

gpm
0
40
80
120
159

dBA SPL
70
72
72
73
73

63
49
48
48
48
49

125
48
50
50
50
51

250
58
58
58
59
60

500
63
63
63
65
67

1K
64
67
67
67
68

2K
64
67
68
68
68

4K
61
63
62
62
62

8K
56
56
58
58
57

RPM
3600

Imp. Dia.
4 in

gpm
0
20
40
70
100

dBA SPL
70
71
72
73
72

63
46
49
49
49
49

125
48
50
50
49
50

250
60
60
59
59
60

500
64
65
65
65
64

1K
64
65
65
67
66

2K
64
65
67
69
68

4K
57
61
62
62
62

8K
51
55
57
57
56

RPM
1800

Imp. Dia.
6 in

gpm
10
50
100

dBA SPL
69
67
66

63
41
41
41

125
50
50
48

250
55
55
54

500
60
61
59

1K
60
61
61

2K
65
62
62

4K
62
55
55

8K
52
47
46

RPM
1800

Imp. Dia.
5 in

gpm
0
30
60
75

dBA SPL
66
66
66
65

63
43
43
44
44

125
50
50
49
50

250
57
57
56
57

500
59
60
59
59

1K
60
60
60
60

2K
60
60
60
59

4K
53
53
54
53

8K
40
42
42
42

13

8K
89
66
62
59
59

50 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1-8

2/10/1999

Flow
3
m /hr
2
11
23
27
32

Total
Unfiltered
dBA SPL
72
72
73
75
77

63
42
41
40
41
44

125
46
46
46
46
47

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
58
59
65
67
65
55
60
66
69
64
54
61
66
70
64
55
63
67
72
67
60
66
69
72
71

8K
60
60
59
62
66

RPM
3000

Imp. Dia.
8 in

RPM
3000

Imp. Dia.
7 in

m /hr
0
9
16
23
26

dBA SPL
69
70
71
72
73

63
47
46
45
45
43

125
49
49
48
48
49

250
56
55
56
54
54

500
60
59
61
60
64

1K
63
63
64
65
69

2K
64
66
67
68
68

4K
63
64
64
65
66

8K
54
57
56
59
60

RPM
3000

Imp. Dia.
6 in

3
m /hr
0
14
18
22

dBA SPL
69
70
69
72

63
42
42
42
42

125
49
50
50
50

250
56
55
55
56

500
60
62
61
62

1K
62
63
62
63

2K
62
63
63
67

4K
63
64
64
66

8K
56
58
59
59

RPM

Imp. Dia.

3
m /hr

dBA SPL

63

125

250

500

1K

2K

4K

8K

1500

7.5 in

0
5
8

66
69
68

41
41
40

46
47
47

51
51
51

54
64
62

61
63
62

62
63
63

56
57
57

48
51
50

11
15

66
67

42
48

47
48

49
49

55
55

61
61

61
63

57
59

50
51

3
m /hr
0
7
9
11

dBA SPL
67
68
67
68

63
43
43
44
43

125
52
52
51
51

250
55
55
55
55

500
60
61
60
61

1K
62
62
61
61

2K
62
63
63
63

4K
58
59
58
59

8K
47
48
48
50

RPM
1500

Imp. Dia.
6 in

14

60 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1-8

2/10/1999

Flow
gpm
10
50
100
120
140

Total
Unfiltered
dBA SPL
76
76
77
79
81

63
46
45
44
45
48

125
50
50
50
50
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
62
64
69
71
69
59
64
70
73
68
58
65
70
74
68
59
67
71
76
71
64
70
73
76
75

RPM
3600

Imp. Dia.
8 in

RPM
3600

Imp. Dia.
7 in

gpm
0
40
70
100
112

dBA SPL
73
74
75
76
77

63
51
50
49
49
47

125
53
53
52
52
53

250
60
59
60
58
58

500
64
63
65
64
68

1K
67
67
68
69
73

2K
68
70
71
72
72

4K
67
68
68
69
70

8K
58
61
60
63
64

RPM
3600

Imp. Dia.
6 in

gpm
0
60
80
95

dBA SPL
73
74
73
75

63
46
46
46
46

125
53
54
54
54

250
60
59
59
60

500
64
66
65
66

1K
66
67
66
67

2K
66
67
67
71

4K
67
68
68
70

8K
60
62
63
63

RPM
1800

Imp. Dia.
7.5 in

gpm
0
20
37
50
66

dBA SPL
68
71
70
68
69

63
43
43
42
44
50

125
48
49
49
49
50

250
53
53
53
51
51

500
56
66
64
57
57

1K
63
65
64
63
63

2K
64
65
65
63
65

4K
58
59
59
59
61

8K
50
53
52
52
53

RPM
1800

Imp. Dia.
6 in

gpm
0
30
40
49

dBA SPL
69
70
69
70

63
45
45
46
45

125
54
54
53
53

250
57
57
57
57

500
62
63
62
63

1K
64
64
63
63

2K
64
65
65
65

4K
60
61
60
61

8K
49
50
50
52

15

8K
64
64
63
66
70

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-82

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
79
75
77
70
71

63
25
29
14
32
29

125
41
42
38
33
36

250
46
57
59
63
65

500
74
71
71
68
67

1K
76
72
74
59
62

2K
68
62
67
59
61

4K
63
54
60
55
62

8K
58
47
55
54
59

m3/hr
4
22
33
44
55

dBA SPL
72
74
74
77
78

63
23
8
14
27
18

125
45
42
38
37
40

250
63
62
64
66
67

500
71
72
73
76
76

1K
59
65
61
65
71

2K
59
61
62
65
57

4K
54
55
58
57
59

8K
44
42
50
46
52

Imp. Dia.
6 in

m3/hr
4
18
27
36
45

dBA SPL
75
78
77
74
76

63
43
43
42
41
43

125
48
45
47
45
48

250
62
61
60
58
62

500
73
74
75
73
71

1K
68
76
73
67
71

2K
63
57
64
60
67

4K
66
63
59
57
63

8K
58
57
56
54
59

Imp. Dia.
8.18 in

m3/hr
3
14

dBA SPL
68
65

63
30
28

125
55
44

250
50
50

500
59
58

1K
67
64

2K
47
48

4K
42
44

8K
31
33

21
29
36

67
65
70

23
21
31

26
43
49

50
50
52

59
59
59

65
62
69

53
56
44

44
41
37

37
31
34

m3/hr
2
11
17
22
28

dBA SPL
63
67
61
63
62

63
30
35
33
31
27

125
32
26
27
27
38

250
51
50
51
52
53

500
59
61
60
59
61

1K
61
65
54
59
47

2K
49
53
42
48
39

4K
37
37
42
40
37

8K
30
31
37
31
31

RPM
3000

Imp. Dia.
8.18 in

RPM
3000

Imp. Dia.
7 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
6
28
42
56
70

Imp. Dia.
7 in

16

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-82

2/10/1999

Flow
gpm
25
123
184
245
306

Total
Unfiltered
dBA SPL
83
79
81
74
75

63
29
33
16
36
33

125
45
46
42
37
40

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
50
78
80
72
67
61
75
76
66
58
63
75
78
71
64
67
72
63
63
59
69
71
66
65
66

RPM
3600

Imp. Dia.
8.18 in

RPM
3600

Imp. Dia.
7 in

gpm
19
97
145
193
241

dBA SPL
76
78
78
81
82

63
27
12
18
31
22

125
49
46
42
41
44

250
67
66
68
70
71

500
75
76
77
80
80

1K
63
69
65
69
75

2K
63
65
66
69
61

4K
58
59
62
61
63

8K
48
46
54
50
56

RPM
3600

Imp. Dia.
6 in

gpm
16
79
119
158
198

dBA SPL
79
82
81
78
80

63
47
47
46
45
47

125
52
49
51
49
52

250
66
65
64
62
66

500
77
78
79
77
75

1K
72
80
77
71
75

2K
67
61
68
64
71

4K
70
67
63
61
67

8K
62
61
60
58
63

RPM
1800

Imp. Dia.
8.18 in

gpm
13
63
94
125
156

dBA SPL
70
67
69
67
72

63
32
30
25
23
33

125
57
46
28
45
51

250
52
52
52
52
54

500
61
60
61
61
61

1K
69
66
67
64
71

2K
49
50
55
58
48

4K
44
46
46
43
39

8K
33
35
39
33
36

RPM
1800

Imp. Dia.
7 in

gpm
10
49
74
98
123

dBA SPL
65
69
63
65
64

63
32
37
35
33
29

125
34
28
29
29
40

250
53
52
53
54
55

500
61
63
62
61
63

1K
63
67
56
61
49

2K
51
55
44
50
41

4K
39
39
44
42
39

8K
32
33
39
33
33

17

8K
62
51
59
58
63

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-82

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
79
75
77
70
71

63
25
29
14
32
29

125
41
42
38
33
36

250
46
57
59
63
65

500
74
71
71
68
67

1K
76
72
74
59
62

2K
68
62
67
59
61

4K
63
54
60
55
62

8K
58
47
55
54
59

m3/hr
4
22
33
44
55

dBA SPL
72
74
74
77
78

63
23
8
14
27
18

125
45
42
38
37
40

250
63
62
64
66
67

500
71
72
73
76
76

1K
59
65
61
65
71

2K
59
61
62
65
57

4K
54
55
58
57
59

8K
44
42
50
46
52

Imp. Dia.
6 in

m3/hr
4
18
27
36
45

dBA SPL
75
78
77
74
76

63
43
43
42
41
43

125
48
45
47
45
48

250
62
61
60
58
62

500
73
74
75
73
71

1K
68
76
73
67
71

2K
63
57
64
60
67

4K
66
63
59
57
63

8K
58
57
56
54
59

Imp. Dia.
8.18 in

m3/hr
3
14

dBA SPL
68
65

63
30
28

125
55
44

250
50
50

500
59
58

1K
67
64

2K
47
48

4K
42
44

8K
31
33

21
29
36

67
65
70

23
21
31

26
43
49

50
50
52

59
59
59

65
62
69

53
56
44

44
41
37

37
31
34

m3/hr
2
11
17
22
28

dBA SPL
63
67
61
63
62

63
30
35
33
31
27

125
32
26
27
27
38

250
51
50
51
52
53

500
59
61
60
59
61

1K
61
65
54
59
47

2K
49
53
42
48
39

4K
37
37
42
40
37

8K
30
31
37
31
31

RPM
3000

Imp. Dia.
8.18 in

RPM
3000

Imp. Dia.
7 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
6
28
42
56
70

Imp. Dia.
7 in

18

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-82

2/10/1999

Flow
gpm
25
123
184
245
306

Total
Unfiltered
dBA SPL
83
79
81
74
75

63
29
33
16
36
33

125
45
46
42
37
40

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
50
78
80
72
67
61
75
76
66
58
63
75
78
71
64
67
72
63
63
59
69
71
66
65
66

RPM
3600

Imp. Dia.
8.18 in

RPM
3600

Imp. Dia.
7 in

gpm
19
97
145
193
241

dBA SPL
76
78
78
81
82

63
27
12
18
31
22

125
49
46
42
41
44

250
67
66
68
70
71

500
75
76
77
80
80

1K
63
69
65
69
75

2K
63
65
66
69
61

4K
58
59
62
61
63

8K
48
46
54
50
56

RPM
3600

Imp. Dia.
6 in

gpm
16
79
119
158
198

dBA SPL
79
82
81
78
80

63
47
47
46
45
47

125
52
49
51
49
52

250
66
65
64
62
66

500
77
78
79
77
75

1K
72
80
77
71
75

2K
67
61
68
64
71

4K
70
67
63
61
67

8K
62
61
60
58
63

RPM
1800

Imp. Dia.
8.18 in

gpm
13
63
94
125
156

dBA SPL
70
67
69
67
72

63
32
30
25
23
33

125
57
46
28
45
51

250
52
52
52
52
54

500
61
60
61
61
61

1K
69
66
67
64
71

2K
49
50
55
58
48

4K
44
46
46
43
39

8K
33
35
39
33
36

RPM
1800

Imp. Dia.
7 in

gpm
10
49
74
98
123

dBA SPL
65
69
63
65
64

63
32
37
35
33
29

125
34
28
29
29
40

250
53
52
53
54
55

500
61
63
62
61
63

1K
63
67
56
61
49

2K
51
55
44
50
41

4K
39
39
44
42
39

8K
32
33
39
33
33

19

8K
62
51
59
58
63

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-8

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
82
80
79
79
79

63
37
37
41
40
39

125
49
48
48
46
50

250
65
64
62
65
64

500
75
73
72
72
74

1K
78
76
76
75
74

2K
77
73
74
72
71

4K
74
71
69
68
69

8K
65
61
59
59
58

m3/hr
18
36
55
73
91

dBA SPL
78
76
76
78
78

63
37
37
37
37
38

125
44
43
45
44
43

250
66
63
62
64
64

500
75
71
70
72
72

1K
70
70
71
73
74

2K
70
70
69
71
70

4K
68
65
66
67
66

8K
63
59
59
58
59

Imp. Dia.
7 in

m3/hr
18
36
55
68
73

dBA SPL
77
75
76
78
78

63
40
39
38
39
42

125
42
42
41
44
45

250
63
61
62
64
62

500
72
69
70
72
71

1K
68
68
69
70
66

2K
72
70
71
74
74

4K
66
67
68
67
68

8K
58
59
59
59
60

Imp. Dia.
8.18 in

m3/hr
9
27

dBA SPL
73
74

63
38
39

125
47
46

250
56
55

500
66
67

1K
70
71

2K
66
65

4K
63
59

8K
54
50

36
46
55

74
73
72

38
39
38

46
47
47

55
55
56

68
66
66

71
70
69

65
65
65

59
59
61

49
49
51

m3/hr
9
27
36
46
55

dBA SPL
70
70
71
70
72

63
42
44
43
43
42

125
46
43
43
43
44

250
54
53
53
53
54

500
62
60
62
62
62

1K
64
64
67
64
65

2K
66
66
67
66
69

4K
62
62
62
61
64

8K
56
55
56
56
57

RPM
3000

Imp. Dia.
8.18 in

RPM
3000

Imp. Dia.
8 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
18
36
55
82
103

Imp. Dia.
7 in

20

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-8

2/10/1999

Flow
gpm
80
160
240
360
450

Total
Unfiltered
dBA SPL
86
84
83
83
83

63
41
41
45
44
43

125
53
52
52
50
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
79
82
81
78
68
77
80
77
75
66
76
80
78
73
69
76
79
76
72
68
78
78
75
73

RPM
3600

Imp. Dia.
8.18 in

RPM
3600

Imp. Dia.
8 in

gpm
80
160
240
320
400

dBA SPL
82
80
80
82
82

63
41
41
41
41
42

125
48
47
49
48
47

250
70
67
66
68
68

500
79
75
74
76
76

1K
74
74
75
77
78

2K
74
74
73
75
74

4K
72
69
70
71
70

8K
67
63
63
62
63

RPM
3600

Imp. Dia.
7 in

gpm
80
160
240
300
320

dBA SPL
81
79
80
82
82

63
44
43
42
43
46

125
46
46
45
48
49

250
67
65
66
68
66

500
76
73
74
76
75

1K
72
72
73
74
74

2K
76
74
75
78
78

4K
70
71
72
71
72

8K
62
63
63
63
64

RPM
1800

Imp. Dia.
8.18 in

gpm
40
120
160
200
240

dBA SPL
75
76
76
75
74

63
40
41
40
41
40

125
49
48
48
49
49

250
58
57
57
57
58

500
68
69
70
68
68

1K
73
73
73
72
71

2K
68
67
67
67
67

4K
65
61
61
61
63

8K
56
52
51
51
53

RPM
1800

Imp. Dia.
7 in

gpm
40
120
160
200
240

dBA SPL
72
72
73
72
74

63
44
46
45
45
44

125
48
45
45
45
46

250
56
55
55
55
56

500
64
62
64
64
64

1K
66
66
69
66
67

2K
68
68
69
68
71

4K
64
64
64
63
66

8K
58
57
58
58
59

21

8K
69
65
63
61
62

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-8

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
90
83
77
71
73

63
37
38
34
32
37

125
46
49
33
44
47

250
72
64
60
59
61

500
85
75
71
69
71

1K
86
80
73
60
57

2K
82
77
69
57
65

4K
80
72
61
50
50

8K
76
66
60
53
57

m3/hr
32
63
95
127
158

dBA SPL
74
73
74
74
68

63
37
37
43
42
40

125
46
45
46
50
50

250
63
61
61
61
60

500
72
70
65
64
66

1K
68
66
70
70
52

2K
65
64
68
69
54

4K
62
60
64
64
52

8K
54
44
40
51
52

Imp. Dia.
6 in

m3/hr
26
51
77
103
128

dBA SPL
71
74
76
75
74

63
34
29
13
24
29

125
24
40
43
28
42

250
61
60
60
60
60

500
45
47
64
61
57

1K
69
71
74
74
72

2K
64
69
69
68
69

4K
52
61
60
61
61

8K
50
52
53
53
56

Imp. Dia.
8.18 in

m3/hr
21
42

dBA SPL
73
71

63
0
0

125
39
43

250
48
58

500
66
65

1K
68
67

2K
68
66

4K
64
61

8K
55
51

63
84
105

72
71
70

0
0
0

43
36
37

60
54
50

66
65
64

67
67
67

66
64
63

60
59
59

33
36
38

m3/hr
16
32
48
64
80

dBA SPL
68
67
69
69
70

63
0
0
0
0
0

125
44
45
44
45
45

250
55
55
55
55
56

500
64
61
64
65
65

1K
63
63
66
66
67

2K
58
58
59
60
58

4K
53
55
54
55
56

8K
34
42
29
35
39

RPM
3000

Imp. Dia.
8.18 in

RPM
3000

Imp. Dia.
7 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
41
83
124
166
207

Imp. Dia.
7 in

22

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-8

2/10/1999

Flow
gpm
182
364
546
728
910

Total
Unfiltered
dBA SPL
94
87
81
75
77

63
41
42
38
36
41

125
50
53
37
48
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
76
89
90
86
84
68
79
84
81
76
64
75
77
73
65
63
73
64
61
54
65
75
61
69
54

RPM
3600

Imp. Dia.
8.18 in

RPM
3600

Imp. Dia.
7 in

gpm
139
278
416
555
694

dBA SPL
78
77
78
78
72

63
41
41
47
46
44

125
50
49
50
54
54

250
67
65
65
66
64

500
76
74
69
68
70

1K
72
70
74
74
56

2K
69
68
72
73
58

4K
66
64
68
68
56

8K
58
48
46
55
56

RPM
3600

Imp. Dia.
6 in

gpm
113
225
338
450
563

dBA SPL
75
78
80
79
78

63
38
33
17
28
33

125
28
44
47
32
46

250
65
64
64
64
64

500
49
51
68
65
61

1K
73
75
78
78
76

2K
68
73
73
72
73

4K
56
65
64
65
65

8K
54
56
57
57
60

RPM
1800

Imp. Dia.
8.18 in

gpm
92
184
275
367
459

dBA SPL
75
73
74
73
72

63
0
0
0
0
0

125
41
45
43
38
39

250
50
60
62
56
52

500
68
67
68
67
66

1K
70
69
69
69
69

2K
70
68
68
66
65

4K
66
63
62
61
61

8K
57
53
35
38
40

RPM
1800

Imp. Dia.
7 in

gpm
70
140
210
280
350

dBA SPL
70
69
71
71
72

63
0
0
0
0
0

125
46
47
46
47
47

250
57
57
57
57
58

500
66
63
66
67
67

1K
65
65
68
68
69

2K
60
60
61
62
60

4K
55
57
56
57
58

8K
36
44
31
37
41

23

8K
80
70
64
57
61

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x1-10A

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
72
65
67
70
84

63
42
42
40
32
40

125
51
50
51
49
50

250
60
57
56
58
62

500
64
60
64
67
68

1K
65
59
58
59
76

2K
65
60
59
61
79

4K
67
53
55
61
78

8K
62
50
50
60
75

m3/hr
2
16
24
32
41

dBA SPL
71
71
72
72
82

63
47
45
46
45
48

125
56
56
55
54
55

250
63
60
61
63
68

500
63
66
68
66
68

1K
67
66
67
66
74

2K
63
63
65
65
78

4K
59
57
57
64
77

8K
58
53
54
52
75

Imp. Dia.
8 in

m3/hr
2.5
13
20
26
33

dBA SPL
70
70
71
71
78

63
47
46
49
50
49

125
56
56
57
57
57

250
63
62
62
62
64

500
58
59
63
64
68

1K
66
66
67
68
72

2K
61
62
63
63
72

4K
56
57
58
59
70

8K
53
54
55
57
67

Imp. Dia.
10 in

m3/hr
3
10

dBA SPL
60
58

63
32
39

125
48
46

250
47
47

500
55
51

1K
54
54

2K
52
51

4K
52
49

8K
48
43

15
20
25

60
61
69

34
23
33

46
42
49

47
47
55

53
53
59

55
56
62

54
54
64

50
54
63

42
51
59

m3/hr
2
8
12
16
20

dBA SPL
61
63
64
63
68

63
40
39
41
40
41

125
50
50
50
50
50

250
52
52
51
52
53

500
55
54
55
55
59

1K
56
59
59
58
62

2K
53
57
60
57
62

4K
50
54
54
53
61

8K
49
49
50
49
57

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
5
18
28
37
46

Imp. Dia.
9 in

24

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x1-10A

2/10/1999

Flow
gpm
20
81
122
162
203

Total
Unfiltered
dBA SPL
76
69
71
74
88

63
46
46
44
36
44

125
55
54
55
53
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
64
68
69
69
71
61
64
63
64
57
60
68
62
63
59
62
71
63
65
65
66
72
80
83
82

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
9
71
107
142
178

dBA SPL
75
75
76
76
86

63
51
49
50
49
52

125
60
60
59
58
59

250
67
64
65
67
72

500
67
70
72
70
72

1K
71
70
71
70
78

2K
67
67
69
69
82

4K
63
61
61
68
81

8K
62
57
58
66
79

RPM
3600

Imp. Dia.
8 in

gpm
11
57
86
114
143

dBA SPL
74
74
75
75
82

63
51
50
53
54
53

125
60
60
61
61
61

250
67
66
66
66
68

500
62
63
67
68
72

1K
70
70
71
72
76

2K
65
66
67
67
76

4K
60
61
62
63
74

8K
57
58
59
61
71

RPM
1800

Imp. Dia.
10 in

gpm
15
43
65
86
108

dBA SPL
62
60
62
63
71

63
34
41
36
25
35

125
50
48
48
44
51

250
49
49
49
49
57

500
57
53
55
55
61

1K
56
56
57
58
64

2K
54
53
56
56
66

4K
54
51
52
56
65

8K
50
45
44
53
61

RPM
1800

Imp. Dia.
9 in

gpm
7
36
53
71
89

dBA SPL
63
65
66
65
70

63
42
41
43
42
43

125
52
52
52
52
52

250
54
54
53
54
55

500
57
56
57
57
61

1K
58
61
61
60
64

2K
55
59
62
59
64

4K
52
56
56
55
63

8K
51
51
52
51
59

25

8K
66
54
54
64
79

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-10A

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
82
80
81
83
87

63
44
45
44
42
42

125
48
49
49
50
49

250
67
61
62
62
63

500
79
73
76
80
79

1K
76
75
75
75
81

2K
74
75
75
76
80

4K
69
71
71
71
81

8K
64
64
64
65
69

m3/hr
9
18
36
46
52

dBA SPL
75
75
76
78
85

63
62
43
42
42
40

125
51
50
51
50
50

250
61
62
62
65
68

500
67
67
69
72
77

1K
70
71
72
72
80

2K
69
70
71
71
81

4K
66
67
69
72
79

8K
58
60
60
64
66

Imp. Dia.
6 in

m3/hr
2
9
18
27
34

dBA SPL
72
72
74
74
78

63
62
42
41
39
39

125
52
51
51
52
52

250
58
56
57
58
60

500
58
58
60
63
68

1K
68
69
70
70
74

2K
67
68
69
69
73

4K
64
64
64
64
71

8K
54
54
56
57
60

Imp. Dia.
10 in

m3/hr
11
17

dBA SPL
72
72

63
38
39

125
49
50

250
58
59

500
63
63

1K
67
68

2K
69
68

4K
63
62

8K
53
52

23
29
34

72
73
78

38
42
42

50
50
50

58
58
59

64
66
69

68
68
74

68
69
72

62
62
69

52
52
57

m3/hr
5
11
17
23
27

dBA SPL
71
72
72
71
76

63
37
36
38
37
37

125
51
52
52
53
52

250
57
56
56
56
58

500
59
61
60
61
66

1K
69
70
70
68
72

2K
64
66
65
63
69

4K
61
62
61
61
68

8K
53
54
53
53
56

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
8 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
18
36
46
55
64

Imp. Dia.
8 in

26

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-10A

2/10/1999

Flow
gpm
80
160
200
240
280

Total
Unfiltered
dBA SPL
86
84
85
87
91

63
48
49
48
46
46

125
52
53
53
54
53

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
71
83
80
78
73
65
77
79
79
75
66
80
79
79
75
66
84
79
80
75
67
83
85
84
85

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
8 in

gpm
40
80
160
200
230

dBA SPL
79
79
80
82
89

63
66
47
46
46
44

125
55
54
55
54
54

250
65
66
66
69
72

500
71
71
73
76
81

1K
74
75
76
76
84

2K
73
74
75
75
85

4K
70
71
73
76
83

8K
62
64
64
68
70

RPM
3600

Imp. Dia.
6 in

gpm
10
40
80
120
150

dBA SPL
76
76
78
78
82

63
66
46
45
43
43

125
56
55
55
56
56

250
62
60
61
62
64

500
62
62
64
67
72

1K
72
73
74
74
78

2K
71
72
73
73
77

4K
68
68
68
68
75

8K
58
58
60
61
64

RPM
1800

Imp. Dia.
10 in

gpm
50
75
100
125
150

dBA SPL
74
74
74
75
80

63
40
41
40
44
44

125
51
52
52
52
52

250
60
61
60
60
61

500
65
65
66
68
71

1K
69
70
70
70
76

2K
71
70
70
71
74

4K
65
64
64
64
71

8K
55
54
54
54
59

RPM
1800

Imp. Dia.
8 in

gpm
20
50
75
100
120

dBA SPL
73
74
74
73
78

63
39
38
40
39
39

125
53
54
54
55
54

250
59
58
58
58
60

500
61
63
62
63
68

1K
71
72
72
70
74

2K
66
68
67
65
71

4K
63
64
63
63
70

8K
55
56
55
55
58

27

8K
68
68
68
69
73

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-10

2/10/1999

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
85
82
81
86
89

63
39
37
39
43
42

125
48
49
53
55
55

250
65
64
65
67
68

500
83
79
76
83
83

1K
76
75
75
78
84

2K
74
75
74
79
84

4K
69
70
71
78
81

8K
62
63
63
69
71

m3/hr
18
36
55
73
87

dBA SPL
75
77
77
78
85

63
36
36
40
38
38

125
45
45
46
47
46

250
60
61
62
65
71

500
69
69
69
70
79

1K
71
72
72
73
80

2K
70
72
73
73
80

4K
65
67
67
69
77

8K
56
59
58
61
67

Imp. Dia.
6 in

m3/hr
9
18
36
55
64

dBA SPL
71
72
73
76
83

63
35
35
36
37
37

125
42
43
44
44
45

250
56
56
57
60
64

500
63
62
65
67
76

1K
65
67
69
71
77

2K
68
69
69
71
79

4K
61
62
63
68
76

8K
54
55
56
59
67

Imp. Dia.
10 in

m3/hr
11
23

dBA SPL
73
73

63
40
39

125
45
52

250
58
59

500
69
68

1K
69
68

2K
66
67

4K
60
60

8K
49
50

34
46
57

74
75
78

40
39
39

51
51
53

57
56
59

69
72
73

69
70
73

67
66
72

60
60
69

51
51
59

m3/hr
9
18
27
36
46

dBA SPL
66
68
69
69
74

63
38
38
36
39
40

125
46
46
456
47
46

250
55
56

500
58
61
62
64
67

1K
61
62
63
62
68

2K
61
63
63
63
70

4K
58
59
59
59
66

8K
48
48
48
48
56

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
8 in

RPM
3000

RPM
1500

RPM
1500

Flow
m3/hr
36
55
73
100
109

Imp. Dia.
8 in

28

57
59

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-10

2/10/1999

Flow
gpm
160
240
320
440
480

Total
Unfiltered
dBA SPL
89
86
85
90
93

63
43
41
43
47
46

125
52
53
57
59
59

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
87
80
78
73
68
83
79
79
74
69
80
79
78
75
71
87
82
83
82
72
87
88
88
85

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
8 in

gpm
80
160
240
320
380

dBA SPL
79
81
81
82
89

63
40
40
44
42
42

125
49
49
50
51
50

250
64
65
66
69
75

500
73
73
73
74
83

1K
75
76
76
77
84

2K
74
76
77
77
84

4K
69
71
71
73
81

8K
60
63
62
65
71

RPM
3600

Imp. Dia.
6 in

gpm
40
80
160
240
280

dBA SPL
75
76
77
80
87

63
39
39
40
41
41

125
46
47
48
48
49

250
60
60
61
64
68

500
67
66
69
71
80

1K
69
71
73
75
81

2K
72
73
73
75
83

4K
65
66
67
72
80

8K
58
59
60
63
71

RPM
1800

Imp. Dia.
10 in

gpm
50
100
150
200
250

dBA SPL
75
75
76
77
80

63
42
41
42
41
41

125
51
54
53
53
55

250
60
61
59
58
61

500
71
70
71
74
75

1K
71
70
71
72
75

2K
68
69
69
68
74

4K
62
63
62
62
71

8K
51
52
53
53
61

RPM
1800

Imp. Dia.
8 in

gpm
40
80
120
160
200

dBA SPL
68
70
71
71
76

63
40
40
38
41
42

125
48
48
47
49
48

250
57
58
58
59
61

500
60
63
64
66
69

1K
63
64
65
64
70

2K
63
65
65
65
72

4K
60
61
61
61
68

8K
50
50
50
50
58

29

8K
66
67
67
73
75

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-10

2/10/1999

Flow
3
m /hr
23
46
91
141
182

Total
Unfiltered
dBA SPL
86
83
81
82
85

63
62
40
44
47
46

125
51
50
54
54
57

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
70
85
77
72
69
70
81
76
74
71
68
76
76
74
71
68
78
76
75
70
70
81
77
78
75

8K
62
65
63
63
68

RPM
3000

Imp. Dia.
9 in

RPM
3000

Imp. Dia.
8 in

m /hr
14
46
91
130

dBA SPL
76
77
78
80

63
62
39
39
43

125
50
49
50
50

250
55
63
64
67

500
71
70
72
74

1K
72
73
74
75

2K
67
69
71
73

4K
65
66
68
70

8K
57
59
63
65

RPM
3000

Imp. Dia.
6 in

m /hr
11
46
91
128

dBA SPL
74
74
77
81

63
62
38
38
38

125
48
49
49
51

250
60
62
62
63

500
71
65
69
76

1K
69
71
73
77

2K
65
68
71
75

4K
60
62
65
71

8K
54
56
60
63

RPM
1500

Imp. Dia.
10 in

m /hr
11
23
46
68
114

dBA SPL
75
74
72
72
78

63
64
41
42
42
42

125
53
52
53
52
54

250
63
59
59
59
61

500
70
69
70
66
72

1K
68
69
68
68
72

2K
68
67
65
65
72

4K
63
62
61
61
70

8K
53
53
53
52
60

RPM
1500

Imp. Dia.
6 in

3
m /hr
6
23
34
46
60

dBA SPL
71
69
68
67
68

63
64
40
41
40
40

125
51
51
51
51
50

250
60
58
57
58
57

500
68
67
66
65
66

1K
60
60
59
59
59

2K
57
58
58
58
59

4K
51
53
52
51
54

8K
43
45
45
43
47

30

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-10

2/10/1999

Flow
gpm
100
200
400
620
800

Total
Unfiltered
dBA SPL
90
87
85
86
89

63
66
44
48
51
50

125
55
54
58
58
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
89
81
76
73
74
85
80
78
75
72
80
80
78
75
72
82
80
79
74
74
85
81
82
79

RPM
3600

Imp. Dia.
9 in

RPM
3600

Imp. Dia.
8 in

gpm
60
200
400
570

dBA SPL
80
81
82
84

63
66
43
43
47

125
54
53
54
54

250
69
67
68
71

500
75
74
76
78

1K
76
77
78
79

2K
71
73
75
77

4K
69
70
72
74

8K
61
63
67
69

RPM
3600

Imp. Dia.
6 in

gpm
50
200
400
560

dBA SPL
78
78
81
85

63
66
42
42
42

125
52
53
53
55

250
64
66
66
67

500
75
69
73
80

1K
73
75
77
81

2K
69
72
75
79

4K
64
66
69
75

8K
58
60
64
67

RPM
1800

Imp. Dia.
10 in

gpm
50
100
200
300
500

dBA SPL
77
76
74
74
80

63
66
43
44
44
44

125
55
54
55
54
56

250
65
61
61
61
63

500
72
71
70
68
74

1K
70
71
70
70
74

2K
70
69
67
67
74

4K
65
64
63
63
72

8K
55
55
55
54
62

RPM
1800

Imp. Dia.
6 in

gpm
25
100
150
200
265

dBA SPL
73
71
70
69
70

63
66
42
43
42
42

125
53
53
53
53
52

250
62
60
59
60
59

500
70
69
68
67
68

1K
62
62
61
61
61

2K
59
60
60
60
61

4K
53
55
54
53
56

8K
45
47
47
45
49

31

8K
66
69
67
67
72

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-10H

2/10/1999
RPM
1500

Imp. Dia.
10 in

RPM
1500

Imp. Dia.
8 in

RPM
1500

Imp. Dia.
6 in

Flow
m3/hr
23
68
114
160
182

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
80
76
73
72
80

63
44
41
41
41
41

125
55
52
52
51
53

250
68
62
56
59
66

500
77
72
68
69
75

1K
72
67
68
66
73

2K
73
71
68
65
74

4K
67
66
61
60
71

8K
57
57
54
53
59

m3/hr
23
68
91
114
137

dBA SPL
68
67
67
69
74

63
41
41
40
40
40

125
50
50
50
50
50

250
54
59
57
62
63

500
65
61
63
66
70

1K
61
62
60
60
68

2K
62
61
59
58
67

4K
57
54
54
51
67

8K
48
48
47
44
54

m3/hr
0
100
200
300
360

dBA SPL
69
65
65
65
65

63
64
41
39
41
40

125
46
45
45
46
47

250
59
54
55
52
51

500
65
60
63
62
62

1K
61
58
58
58
58

2K
56
57
56
56
57

4K
56
55
50
51
52

8K
51
51
46
45
46

32

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-10H

2/10/1999

Flow
gpm
100
300
500
700
800

Total
Unfiltered
dBA SPL
82
78
75
74
82

63
46
43
43
43
43

125
57
54
54
53
55

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
70
79
74
75
69
64
74
69
73
68
58
70
70
70
63
61
71
68
67
62
68
77
75
76
73

RPM
1800

Imp. Dia.
10 in

RPM
1800

Imp. Dia.
8 in

gpm
100
300
400
500
600

dBA SPL
70
69
69
71
76

63
43
43
42
42
42

125
52
52
52
52
52

250
56
61
60
64
65

500
67
63
65
68
72

1K
63
64
62
62
70

2K
64
63
61
60
69

4K
59
56
56
53
69

8K
50
50
49
46
56

RPM
1800

Imp. Dia.
6 in

gpm
0
100
200
300
360

dBA SPL
71
67
67
67
67

63
66
43
41
43
42

125
48
47
47
48
49

250
61
56
57
54
53

500
67
62
65
64
64

1K
63
61
60
60
60

2K
58
59
58
58
59

4K
58
57
52
53
54

8K
53
53
48
47
48

33

8K
59
59
56
55
61

50 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-10

2/10/1999

Flow
3
m /hr
71
143
214
285
356

Total
Unfiltered
dBA SPL
88
84
85
83
90

63
38
26
42
41
36

125
41
46
45
43
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
78
82
83
79
66
74
78
79
77
73
77
77
81
77
65
73
76
78
78
79
84
83
85
82

8K
73
70
69
69
78

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

m /hr
61
122
183
244
305

dBA SPL
81
81
80
82
81

63
31
38
42
37
37

125
47
40
42
43
51

250
73
68
65
63
66

500
76
73
73
71
73

1K
72
75
74
73
73

2K
76
77
73
80
77

4K
72
72
73
75
73

8K
65
64
66
66
67

RPM
3000

Imp. Dia.
8 in

m /hr
56
112
168
223
279

dBA SPL
73
76
79
82
80

63
42
42
39
35
38

125
50
48
37
37
39

250
61
63
63
56
56

500
51
69
71
69
69

1K
66
69
72
71
69

2K
70
72
74
81
79

4K
66
67
69
71
70

8K
59
63
63
65
66

RPM
1500

Imp. Dia.
10 in

m /hr
37
74
111
148
184

dBA SPL
76
77
79
77
80

63
0
0
0
0
0

125
29
44
46
48
53

250
63
51
75
58
60

500
65
66
71
72
64

1K
71
72
72
72
70

2K
72
74
73
72
79

4K
65
66
66
65
63

8K
58
56
55
51
38

RPM
1500

Imp. Dia.
9 in

m /hr
34
68
102
135
169

dBA SPL
70
73
73
73
72

63
0
0
0
0
0

125
46
47
47
50
46

250
53
53
57
58
54

500
64
65
66
66
66

1K
67
70
71
71
70

2K
62
68
66
66
61

4K
40
52
56
55
52

8K
50
48
51
50
52

34

60 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-10

2/10/1999

Flow
gpm
313
625
938
1250
1563

Total
Unfiltered
dBA SPL
92
88
89
87
94

63
42
30
46
45
40

125
45
50
49
47
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
81
82
86
87
83
70
78
82
83
81
77
81
81
85
81
69
77
80
82
82
83
88
87
89
86

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
268
535
803
1070
1338

dBA SPL
85
85
84
86
85

63
35
42
46
41
41

125
51
44
46
47
55

250
77
72
69
67
70

500
80
77
77
75
77

1K
76
79
78
77
77

2K
80
81
77
84
81

4K
76
76
77
79
77

8K
69
68
70
70
71

RPM
3600

Imp. Dia.
8 in

gpm
245
490
735
980
1225

dBA SPL
77
80
83
86
84

63
46
46
43
39
42

125
54
52
41
41
43

250
65
67
67
60
60

500
55
73
75
73
73

1K
70
73
76
75
73

2K
74
76
78
85
83

4K
70
71
73
75
74

8K
63
67
67
69
70

RPM
1800

Imp. Dia.
10 in

gpm
162
324
485
647
809

dBA SPL
78
79
81
79
82

63
0
0
0
0
0

125
31
46
48
50
55

250
65
53
77
60
62

500
67
68
73
74
66

1K
73
74
74
74
72

2K
74
76
75
74
81

4K
67
68
68
67
65

8K
60
58
57
53
40

RPM
1800

Imp. Dia.
9 in

gpm
149
297
446
594
743

dBA SPL
72
75
75
75
74

63
0
0
0
0
0

125
48
49
49
52
48

250
55
55
59
60
56

500
66
67
68
68
68

1K
69
72
73
73
72

2K
64
70
68
68
63

4K
42
54
58
57
54

8K
52
50
53
52
54

35

8K
77
74
73
73
82

Durco
60 Hz SOUND PRESSURE LEVELS

Pump Size: 6x4-10H

11/2/2001
Flow
gpm
280
560
845
1125
1400

Total
Unfiltered
dBA SPL
72
72
70
69
70

63
32
34
33
33
33

125
42
41
45
42
35

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
61
65
65
69
63
61
64
62
66
67
54
60
62
66
63
55
56
58
62
68
54
58
60
63
68

RPM
1800

Imp. Dia.
10 in.

RPM
1800

Imp. Dia.
9 in.

gpm
220
440
660
880
1100

dBA SPL
70
72
73
71
72

63
0
0
0
0
0

125
38
40
34
38
36

250
61
54
52
46
46

500
60
61
55
50
57

1K
65
65
57
56
57

2K
64
64
60
54
58

4K
63
70
72
71
72

8K
57
53
56
55
58

RPM
1800

Imp. Dia.
8 in.

gpm
200
400
600
800
1000

dBA SPL
69
65
68
65
66

63
0
0
0
0
0

125
40
39
38
35
40

250
50
49
38
51
49

500
55
57
51
57
53

1K
63
60
52
59
59

2K
58
55
57
45
56

4K
67
61
67
62
63

8K
55
51
28
53
56

RPM
1200

Imp. Dia.
10 in.

gpm
190
385
580
770
960

dBA SPL
63
66
65
62
66

63
0
0
0
0
0

125
34
37
38
41
37

250
45
43
46
46
44

500
49
48
46
49
51

1K
56
62
62
58
60

2K
53
47
48
47
53

4K
52
60
60
48
63

8K
60
60
57
59
61

36

8K
57
53
56
44
50

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-13

2/10/1999

Flow
3
m /hr
23
46
68
91
114

Total
Unfiltered
dBA SPL
81
79
79
81
88

63
50
49
47
46
49

125
67
67
66
67
67

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
70
74
77
74
67
66
72
75
73
66
67
72
75
73
67
69
72
77
76
70
71
76
82
85
81

8K
59
59
60
61
75

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
11 in

m /hr
18
36
55
73
91

dBA SPL
79
79
79
79
83

63
44
44
44
43
44

125
69
69
70
70
71

250
66
66
67
67
69

500
72
73
73
73
72

1K
75
76
76
75
75

2K
70
71
70
71
77

4K
65
65
65
66
77

8K
59
59
59
59
70

RPM
3000

Imp. Dia.
9 in

m /hr
17
34
51
68
80

dBA SPL
78
78
78
78
83

63
46
45
47
44
47

125
66
66
66
66
69

250
65
66
66
67
68

500
72
72
72
71
74

1K
75
74
74
73
78

2K
69
69
71
70
77

4K
65
66
66
69
75

8K
59
60
61
63
69

RPM
1500

Imp. Dia.
13 in

3
m /hr
9
18
36
46
59

dBA SPL
80
75
74
74
82

63
41
40
41
40
40

125
51
50
48
48
49

250
77
66
62
61
64

500
75
71
68
69
73

1K
71
68
69
70
77

2K
69
67
68
68
76

4K
65
63
62
62
77

8K
58
57
55
55
65

RPM
1500

Imp. Dia.
11 in

3
m /hr
9
18
27
36
52

dBA SPL
73
72
73
72
81

63
39
40
39
40
40

125
47
47
47
47
47

250
65
62
62
60
60

500
66
64
66
65
73

1K
69
68
68
68
77

2K
66
65
66
65
74

4K
61
61
61
61
74

8K
58
58
57
56
63

37

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5-13

2/10/1999

Flow
gpm
100
200
300
401
500

Total
Unfiltered
dBA SPL
85
83
83
85
92

63
54
53
51
50
53

125
71
71
70
71
71

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
78
81
78
71
70
76
79
77
70
71
76
79
77
71
73
76
81
80
74
75
80
86
89
85

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
11 in

gpm
80
160
240
320
400

dBA SPL
83
83
83
83
87

63
48
48
48
47
47

125
73
73
74
74
75

250
70
70
71
71
73

500
76
77
77
77
76

1K
79
80
80
79
79

2K
74
75
74
75
81

4K
69
69
69
70
81

8K
63
63
63
63
74

RPM
3600

Imp. Dia.
9 in

gpm
75
150
225
300
350

dBA SPL
82
82
82
82
87

63
50
49
51
48
51

125
70
70
70
70
73

250
69
70
70
71
72

500
76
76
76
75
78

1K
79
78
78
77
82

2K
73
73
75
74
81

4K
69
70
70
73
79

8K
63
64
65
67
73

RPM
1800

Imp. Dia.
13 in

gpm
40
80
160
200
260

dBA SPL
82
77
76
76
84

63
43
42
43
42
42

125
53
52
50
50
51

250
79
68
64
63
66

500
77
73
70
71
75

1K
73
70
71
72
79

2K
71
69
70
70
78

4K
67
65
64
64
79

8K
60
59
57
57
67

RPM
1800

Imp. Dia.
11 in

gpm
40
80
120
160
230

dBA SPL
75
74
75
74
83

63
41
42
41
42
42

125
49
49
49
49
49

250
67
64
64
62
62

500
68
66
68
67
75

1K
71
70
70
70
79

2K
68
67
68
67
76

4K
63
63
63
63
76

8K
60
60
59
58
65

38

8K
63
63
64
65
79

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-13

2/10/1999

Flow
3
m /hr
34
68
103
137
157

Total
Unfiltered
dBA SPL
87
85
86
87
93

63
35
32
44
48
44

125
59
58
48
48
60

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
77
80
85
80
70
77
80
81
76
70
78
81
82
78
69
77
81
83
80
71
82
89
89
85

8K
74
70
69
72
80

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
12 in

m /hr
30
60
90
120
150

dBA SPL
83
82
84
85
89

63
38
38
46
49
46

125
44
42
47
47
52

250
64
63
65
66
69

500
76
75
75
76
79

1K
77
76
79
79
83

2K
79
77
80
81
84

4K
73
74
75
78
81

8K
68
66
66
69
75

RPM
3000

Imp. Dia.
11 in

m /hr
27
54
84
108
135

dBA SPL
80
80
82
82
83

63
37
39
47
44
47

125
39
41
45
44
44

250
59
59
63
63
63

500
71
71
72
72
73

1K
72
75
77
76
77

2K
78
77
78
78
79

4K
70
72
74
74
76

8K
63
62
64
65
70

RPM
1500

Imp. Dia.
13 in

m /hr
18
36
54
72
90

dBA SPL
75
74
75
76
75

63
0
0
0
0
38

125
45
36
32
33
29

250
55
49
56
63
67

500
64
63
65
66
66

1K
69
68
71
71
71

2K
71
69
71
71
70

4K
68
68
67
68
66

8K
60
57
53
54
55

RPM
1500

Imp. Dia.
12 in

m /hr
16
32
48
65
81

dBA SPL
71
73
75
78
76

63
0
42
0
0
0

125
43
44
28
29
32

250
53
48
55
70
50

500
63
63
64
66
67

1K
69
71
72
73
74

2K
63
66
71
72
71

4K
56
61
60
64
64

8K
32
35
32
50
44

39

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2-13

2/10/1999

Flow
gpm
150
300
450
600
690

Total
Unfiltered
dBA SPL
91
89
90
91
97

63
39
36
48
52
48

125
63
62
52
52
64

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
72
81
84
89
84
74
81
84
85
80
74
82
85
86
82
73
81
85
87
84
75
86
93
91
89

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
12 in

gpm
131
263
394
525
656

dBA SPL
87
86
88
89
93

63
42
42
50
53
50

125
48
46
51
51
56

250
68
67
69
70
73

500
80
79
79
80
83

1K
81
80
83
83
87

2K
83
81
84
85
88

4K
77
78
79
82
85

8K
72
70
70
73
79

RPM
3600

Imp. Dia.
11 in

gpm
119
238
356
475
594

dBA SPL
84
84
86
86
87

63
41
43
51
48
51

125
43
45
49
48
48

250
63
63
67
67
67

500
75
75
76
76
77

1K
76
79
81
80
81

2K
82
81
82
82
83

4K
74
76
78
78
80

8K
67
66
68
69
74

RPM
1800

Imp. Dia.
13 in

gpm
79
158
236
315
394

dBA SPL
77
76
77
78
77

63
0
0
0
0
40

125
47
38
34
35
31

250
57
51
58
65
69

500
66
65
67
68
68

1K
71
70
73
73
73

2K
73
71
73
73
72

4K
70
70
69
70
68

8K
62
59
55
56
57

RPM
1800

Imp. Dia.
12 in

gpm
71
142
212
283
354

dBA SPL
73
75
77
80
78

63
0
44
0
0
0

125
45
46
30
31
34

250
55
50
57
72
52

500
65
65
66
68
69

1K
71
73
74
75
76

2K
65
68
73
74
73

4K
58
63
62
66
66

8K
34
37
34
52
46

40

8K
78
74
73
76
84

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-13

2/10/1999

Flow
3
m /hr
45
91
136
182
220

Total
Unfiltered
dBA SPL
81
79
81
82
95

63
45
45
45
46
52

125
63
63
63
62
74

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
77
74
74
70
70
73
73
73
70
70
73
74
76
73
68
75
76
78
74
80
85
88
91
90

8K
64
63
66
66
82

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
10 in

m /hr
46
137
183
205
221

dBA SPL
78
80
81
83
93

63
46
44
45
47
52

125
64
64
64
66
68

250
71
70
71
73
83

500
72
73
73
74
86

1K
73
74
76
78
88

2K
70
73
75
78
87

4K
68
73
73
73
83

8K
63
65
65
67
76

RPM
3000

Imp. Dia.
9 in

m /hr
47
93
137
194
217

dBA SPL
76
78
79
81
91

63
46
43
41
42
50

125
67
67
64
62
64

250
65
69
69
69
78

500
70
71
71
73
82

1K
70
71
72
76
85

2K
69
70
73
75
86

4K
67
71
73
74
83

8K
61
65
65
66
75

RPM
1500

Imp. Dia.
13 in

m /hr
45
91
136
182
200

dBA SPL
80
78
77
83
88

63
41
39
39
41
42

125
51
49
51
55
55

250
73
68
66
68
72

500
72
70
70
76
82

1K
74
72
72
78
83

2K
75
73
72
77
82

4K
70
68
66
73
79

8K
61
59
57
63
68

RPM
1500

Imp. Dia.
10 in

m /hr
45
68
91
114
136

dBA SPL
74
74
74
74
77

63
38
40
40
41
42

125
46
47
48
50
50

250
59
56
57
63
62

500
65
65
65
67
67

1K
71
69
70
71
72

2K
70
70
70
68
72

4K
64
65
65
63
69

8K
56
56
57
55
58

41

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-13

2/10/1999

Flow
gpm
200
400
600
800
967

Total
Unfiltered
dBA SPL
85
83
85
86
99

63
49
49
49
50
56

125
67
67
67
66
78

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
81
78
78
74
74
77
77
77
74
74
77
78
80
77
72
79
80
82
78
84
89
92
95
94

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
10 in

gpm
201
599
801
900
971

dBA SPL
82
84
85
87
97

63
50
48
49
51
56

125
68
68
68
70
72

250
75
74
75
77
87

500
76
77
77
78
90

1K
77
78
80
82
92

2K
74
77
79
82
91

4K
72
77
77
77
87

8K
67
69
69
71
80

RPM
3600

Imp. Dia.
9 in

gpm
204
406
600
852
953

dBA SPL
80
82
83
85
95

63
50
47
45
46
54

125
71
71
68
66
68

250
69
73
73
73
82

500
74
75
75
77
86

1K
74
75
76
80
89

2K
73
74
77
79
90

4K
71
75
77
78
87

8K
65
69
69
70
79

RPM
1800

Imp. Dia.
13 in

gpm
200
400
600
800
880

dBA SPL
82
80
79
85
90

63
43
41
41
43
44

125
53
51
53
57
57

250
75
70
68
70
74

500
74
72
72
78
84

1K
76
74
74
80
85

2K
77
75
74
79
84

4K
72
70
68
75
81

8K
63
61
59
65
70

RPM
1800

Imp. Dia.
10 in

gpm
200
300
400
500
600

dBA SPL
76
76
76
76
79

63
40
42
42
43
44

125
48
49
50
52
52

250
61
58
59
65
64

500
67
67
67
69
69

1K
73
71
72
73
74

2K
72
72
72
70
74

4K
66
67
67
65
71

8K
58
58
59
57
60

42

8K
68
67
70
70
86

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-13HH

2/10/1999

Flow
3
m /hr
14
70
105
140
175

Total
Unfiltered
dBA SPL
84
80
74
69
73

63
36
42
40
40
42

125
72
65
58
65
68

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
65
73
74
81
76
63
66
72
77
73
60
58
59
72
68
58
59
41
62
59
60
66
63
66
62

8K
68
61
50
47
52

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
12 in

m /hr
12
61
91
122
152

dBA SPL
72
67
69
69
71

63
25
33
41
41
41

125
65
63
63
65
64

250
61
58
57
58
58

500
57
61
56
59
62

1K
65
57
59
61
66

2K
63
54
65
64
64

4K
66
59
60
57
59

8K
56
47
45
36
41

RPM
1500

Imp. Dia.
11 in

m /hr
10
51
77
103
128

dBA SPL
70
70
71
70
70

63
18
31
33
37
39

125
61
57
59
54
55

250
57
57
57
59
57

500
59
60
62
63
64

1K
69
68
68
67
67

2K
47
58
64
57
62

4K
48
59
60
58
59

8K
30
28
39
35
47

RPM
1000

Imp. Dia.
13 in

m /hr
10
48
72
96
120

dBA SPL
73
72
66
67
65

63
38
19
18
15
0

125
52
49
50
48
49

250
58
43
44
41
34

500
65
65
65
63
61

1K
67
68
53
59
58

2K
68
67
56
62
59

4K
63
63
56
57
53

8K
55
52
37
36
34

RPM
1000

Imp. Dia.
12 in

3
m /hr
8
40
61
81
101

dBA SPL
60
62
65
64
60

63
0
0
0
0
0

125
42
42
40
42
39

250
22
21
25
22
21

500
53
55
58
51
52

1K
59
60
63
62
57

2K
50
55
57
58
54

4K
43
50
54
55
54

8K
30
29
35
31
28

43

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3-13HH

2/10/1999

Flow
gpm
62
308
461
615
769

Total
Unfiltered
dBA SPL
86
82
76
71
75

63
38
44
42
42
44

125
74
67
60
67
70

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
67
75
76
83
78
65
68
74
79
75
62
60
61
74
70
60
61
43
64
61
62
68
65
68
64

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
12 in

gpm
53
267
400
533
665

dBA SPL
74
69
71
71
73

63
27
35
43
43
43

125
67
65
65
67
66

250
63
60
59
60
60

500
59
63
58
61
64

1K
67
59
61
63
68

2K
65
56
67
66
66

4K
68
61
62
59
61

8K
58
49
47
38
43

RPM
1800

Imp. Dia.
11 in

gpm
45
225
338
450
563

dBA SPL
72
72
73
72
72

63
20
33
35
39
41

125
63
58
61
56
57

250
59
59
59
61
59

500
61
62
64
65
66

1K
71
70
70
69
69

2K
49
60
66
59
64

4K
50
61
62
60
61

8K
32
30
41
37
49

RPM
1200

Imp. Dia.
13 in

gpm
42
211
317
422
528

dBA SPL
74
73
67
68
66

63
39
20
17
16
0

125
53
50
51
49
50

250
59
44
45
42
35

500
66
66
66
64
62

1K
68
69
54
60
59

2K
69
68
57
63
60

4K
64
64
57
58
54

8K
56
53
38
37
35

RPM
1200

Imp. Dia.
12 in

gpm
35
177
266
354
443

dBA SPL
61
63
66
65
61

63
0
0
0
0
0

125
43
43
41
43
40

250
23
22
26
23
22

500
54
56
59
52
43

1K
60
61
64
63
58

2K
51
56
58
59
55

4K
44
51
55
56
55

8K
31
30
36
32
29

44

8K
70
63
52
49
54

50 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-13A

2/10/1999

Flow
3
m /hr
23
91
182
274
365

Total
Unfiltered
dBA SPL
87
84
81
80
79

63
41
42
51
49
43

125
62
58
58
61
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
70
82
82
81
76
68
76
80
79
73
69
75
76
75
70
69
74
75
75
68
66
71
75
75
69

8K
67
65
62
59
59

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
11 in

m /hr
13
91
228
274
308

dBA SPL
78
78
78
74
73

63
39
41
42
40
39

125
53
51
52
49
49

250
66
64
65
59
56

500
74
73
74
67
66

1K
72
73
74
69
68

2K
72
71
71
67
66

4K
68
67
67
65
65

8K
60
61
61
58
57

RPM
1500

Imp. Dia.
9 in

m /hr
23
91
137
182
228

dBA SPL
68
74
75
75
71

63
33
35
38
35
34

125
46
46
49
47
46

250
49
55
61
60
56

500
56
68
70
69
63

1K
63
71
71
70
66

2K
65
67
68
67
66

4K
57
63
64
63
63

8K
47
57
59
59
57

45

60 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-13A

2/10/1999

Flow
gpm
100
400
800
1200
1600

Total
Unfiltered
dBA SPL
89
86
83
82
81

63
43
44
53
51
45

125
64
60
60
63
60

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
72
84
84
83
78
70
78
82
81
75
71
77
78
77
72
71
76
77
77
70
68
73
77
77
71

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
11 in

gpm
100
400
1000
1200
1350

dBA SPL
80
80
80
76
75

63
41
43
44
42
41

125
55
53
54
51
51

250
68
66
67
61
58

500
76
75
76
69
68

1K
74
75
76
71
70

2K
74
73
73
69
68

4K
70
69
69
67
67

8K
62
63
63
60
59

RPM
1800

Imp. Dia.
9 in

gpm
100
400
600
800
1000

dBA SPL
70
76
77
77
73

63
35
37
40
37
36

125
48
48
51
49
48

250
51
57
63
62
58

500
58
70
72
71
65

1K
65
73
73
72
68

2K
67
69
70
69
68

4K
59
65
66
65
65

8K
49
59
61
61
59

46

8K
69
67
64
61
61

50 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-14A

2/10/1999

Flow
3
m /hr
167
264
434
628
750

Total
Unfiltered
dBA SPL
87
84
82
83
84

63
48
51
51
52
48

125
70
68
64
63
66

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
80
82
80
77
72
76
78
79
74
70
72
75
79
73
70
74
75
80
72
69
75
79
79
74

8K
70
68
66
64
67

RPM
1500

Imp. Dia.
14 in

RPM
1500

Imp. Dia.
12 in

m /hr
210
422
582
681

dBA SPL
80
80
81
81

63
47
54
47
46

125
62
65
63
65

250
67
68
67
67

500
72
71
72
73

1K
74
74
74
75

2K
76
76
76
76

4K
73
73
73
73

8K
64
65
65
65

RPM
1500

Imp. Dia.
11 in

m /hr
131
365
524
593

dBA SPL
82
82
81
82

63
47
54
45
44

125
65
66
64
65

250
67
68
66
67

500
71
71
70
73

1K
74
75
74
75

2K
79
79
78
79

4K
72
73
72
72

8K
63
64
64
64

RPM
1000

Imp. Dia.
14 in

m /hr
123
229
350
472
559

dBA SPL
79
77
75
75
76

63
56
54
51
51
50

125
76
74
71
72
69

250
66
67
65
65
67

500
72
69
67
66
69

1K
71
68
67
67
69

2K
68
64
66
67
67

4K
64
59
60
62
63

8K
53
51
54
55
54

47

60 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-14A

2/10/1999

Flow
gpm
734
1160
1904
2755
3288

Total
Unfiltered
dBA SPL
89
86
84
85
86

63
50
53
53
54
50

125
72
70
66
65
68

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
82
84
82
79
74
78
80
81
76
72
74
77
81
75
72
76
77
82
74
71
77
81
81
76

RPM
1800

Imp. Dia.
14 in

RPM
1800

Imp. Dia.
12 in

gpm
920
1850
2550
2990

dBA SPL
82
82
83
83

63
49
56
49
48

125
64
67
65
67

250
69
70
69
69

500
74
73
74
75

1K
76
76
76
77

2K
78
78
78
78

4K
75
75
75
75

8K
66
67
67
67

RPM
1800

Imp. Dia.
11 in

gpm
575
1600
2300
2600

dBA SPL
84
84
83
84

63
49
56
47
46

125
67
68
66
67

250
69
70
68
69

500
73
73
72
75

1K
76
77
76
77

2K
81
81
80
81

4K
74
75
74
74

8K
65
66
66
66

RPM
1200

Imp. Dia.
14 in

gpm
540
1004
1535
2070
2450

dBA SPL
80
78
76
76
77

63
57
55
52
52
51

125
77
75
72
73
70

250
67
68
66
66
68

500
73
70
68
67
70

1K
72
69
68
68
70

2K
69
65
67
68
68

4K
65
60
61
63
64

8K
54
52
55
56
55

48

8K
72
70
68
66
69

49

50

50 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-16

2/10/1999

Flow
3
m /hr
84
169
253
337
422

Total
Unfiltered
dBA SPL
81
79
83
78
74

63
47
45
41
43
46

125
66
61
59
58
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
66
65
75
77
74
40
48
75
72
75
34
71
78
78
77
33
49
70
76
71
33
44
70
70
67

8K
66
66
62
60
58

RPM
1500

Imp. Dia.
16 in

RPM
1500

Imp. Dia.
15 in

m /hr
78
155
233
310
388

dBA SPL
77
76
77
78
78

63
41
41
43
44
43

125
59
54
54
43
55

250
69
67
67
68
68

500
69
65
62
57
67

1K
70
67
66
72
72

2K
74
74
76
77
74

4K
63
57
55
54
52

8K
60
58
59
58
57

RPM
1500

Imp. Dia.
14 in

m /hr
71
142
213
284
355

dBA SPL
75
73
75
77
77

63
42
40
40
42
41

125
48
50
49
56
59

250
65
65
65
66
69

500
65
62
60
61
65

1K
70
61
66
71
72

2K
72
72
74
75
74

4K
57
57
55
54
53

8K
47
49
46
43
44

RPM
1000

Imp. Dia.
16 in

m /hr
59
119
178
237
296

dBA SPL
69
69
69
69
67

63
40
40
39
39
40

125
55
51
25
45
33

250
60
41
39
39
50

500
48
56
55
63
48

1K
59
54
52
62
50

2K
67
69
69
66
66

4K
50
50
46
46
43

8K
40
39
38
34
31

RPM
1000

Imp. Dia.
15 in

m /hr
50
100
150
200
249

dBA SPL
67
70
65
69
70

63
43
41
42
41
42

125
60
53
49
45
54

250
52
43
39
29
35

500
64
64
58
48
57

1K
56
64
64
68
70

2K
61
67
51
61
50

4K
35
47
44
43
34

8K
35
41
37
37
33

51

60 Hz SOUND PRESSURE LEVELS

Pump size: 6x4-16

2/10/1999

Flow
gpm
370
740
1110
1480
1850

Total
Unfiltered
dBA SPL
83
81
85
80
76

63
49
47
43
45
48

125
68
63
61
60
60

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
67
77
79
76
42
50
77
74
77
36
73
80
80
79
35
51
72
78
73
35
46
72
72
69

RPM
1800

Imp. Dia.
16 in

RPM
1800

Imp. Dia.
15 in

gpm
340
680
1020
1360
1700

dBA SPL
79
78
79
80
80

63
43
43
45
46
45

125
61
56
56
45
57

250
71
69
69
70
70

500
71
67
64
59
69

1K
72
69
68
74
74

2K
76
76
78
79
76

4K
65
59
57
56
54

8K
62
60
61
60
59

RPM
1800

Imp. Dia.
14 in

gpm
311
623
934
1245
1556

dBA SPL
77
75
77
79
79

63
44
42
42
44
43

125
50
52
51
58
61

250
67
67
67
68
71

500
67
64
62
63
67

1K
72
63
68
73
74

2K
74
74
76
77
76

4K
59
59
57
56
55

8K
49
51
48
45
46

RPM
1200

Imp. Dia.
16 in

gpm
260
520
780
1040
1300

dBA SPL
70
70
70
70
68

63
41
41
40
40
41

125
56
52
26
46
34

250
61
42
40
40
51

500
49
57
56
64
49

1K
60
55
53
63
51

2K
68
70
70
67
67

4K
51
51
47
47
44

8K
41
40
39
35
32

RPM
1200

Imp. Dia.
15 in

gpm
219
438
656
875
1094

dBA SPL
68
71
66
70
71

63
44
42
43
42
43

125
61
54
50
46
55

250
53
44
40
30
36

500
65
65
59
49
58

1K
57
65
65
69
71

2K
62
68
52
62
51

4K
36
48
45
44
35

8K
36
42
38
38
34

52

8K
68
68
64
62
60

50 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-16

2/10/1999

Flow
3
m /hr
228
456
684
821
912

Total
Unfiltered
dBA SPL
87
85
84
84
89

63
54
54
54
54
54

125
68
70
69
66
67

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
77
82
82
77
75
76
79
80
78
72
77
78
79
75
72
78
80
78
73
73
81
84
85
77

8K
71
71
67
67
67

RPM
1500

Imp. Dia.
16 in

RPM
1500

Imp. Dia.
15 in

3
m /hr
0
319
440
644
896

dBA SPL
86
83
85
84
88

63
51
54
54
55
49

125
68
67
68
66
68

250
74
72
72
71
72

500
77
74
76
75
79

1K
81
76
79
78
83

2K
81
79
81
81
84

4K
76
74
75
74
78

8K
70
68
71
68
69

RPM
1500

Imp. Dia.
13.5 in

m /hr
223
488
752

dBA SPL
84
87
87

63
51
52
54

125
62
69
63

250
70
72
72

500
73
75
78

1K
76
81
80

2K
81
83
82

4K
75
79
76

8K
67
72
78

RPM
1500

Imp. Dia.
12 in

3
m /hr
0
137
228
456
684

dBA SPL
82
81
82
82
83

63
47
48
48
49
49

125
61
61
61
62
62

250
67
68
68
68
68

500
71
71
74
74
74

1K
75
75
75
75
76

2K
80
78
78
78
80

4K
72
72
72
72
73

8K
63
63
63
64
64

RPM
1000

Imp. Dia.
16 in

3
m /hr
0
244
391
611

dBA SPL
84
81
79
80

63
45
47
50
49

125
65
63
63
62

250
66
65
66
63

500
73
69
70
69

1K
80
76
74
74

2K
80
77
73
76

4K
76
72
70
73

8K
70
64
62
62

53

60 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-16

2/10/1999

Flow
gpm
1000
2000
3000
3600
4000

Total
Unfiltered
dBA SPL
89
87
86
86
91

63
56
56
56
56
56

125
70
72
69
68
69

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
79
84
84
79
77
78
81
82
80
74
79
80
81
77
74
80
82
80
75
75
83
86
87
79

RPM
1800

Imp. Dia.
16 in

RPM
1800

Imp. Dia.
15 in

gpm
0
1400
1930
2825
3930

dBA SPL
88
85
87
86
90

63
53
56
56
57
51

125
70
69
70
68
70

250
76
74
74
73
74

500
79
76
78
77
81

1K
83
78
81
80
85

2K
83
81
83
83
86

4K
78
76
77
76
80

8K
72
70
73
70
71

RPM
1800

Imp. Dia.
13.5 in

gpm
980
2140
3300

dBA SPL
86
89
89

63
53
54
56

125
64
71
65

250
72
74
74

500
75
77
80

1K
78
83
82

2K
83
85
84

4K
77
81
78

8K
69
74
80

RPM
1800

Imp. Dia.
12 in

gpm
0
600
1000
2000
3000

dBA SPL
84
83
84
84
85

63
49
50
50
51
51

125
63
63
63
64
64

250
69
70
70
70
70

500
73
73
76
76
76

1K
77
77
77
77
78

2K
82
80
80
80
82

4K
74
74
74
74
75

8K
65
65
65
66
66

RPM
1200

Imp. Dia.
16 in

gpm
0
1070
1715
2680

dBA SPL
85
82
80
81

63
46
48
51
50

125
66
64
64
63

250
67
66
67
64

500
74
70
71
70

1K
81
77
75
75

2K
81
78
74
77

4K
77
73
71
74

8K
71
65
63
63

54

8K
73
73
69
69
69

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-16A

Flow
gpm
675
1325
2000
2650
3325

Total
Unfiltered
dBA SPL
84
83
81
82
84

63
60
36
40
40
44

125
76
67
67
65
75

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
74
75
78
78
68
74
77
77
76
65
68
75
75
76
68
72
76
77
76
74
72
78
78
77

RPM
1800

Imp. Dia.
16 in.

RPM
1800

Imp. Dia.
15 in.

gpm
634
1268
1902
2536
3170

dBA SPL
82
82
81
83
84

63
40
38
29
35
41

125
71
69
71
72
77

250
70
69
71
72
77

500
72
71
69
71
69

1K
78
76
73
78
77

2K
76
77
77
78
77

4K
74
74
75
75
76

8K
60
60
61
61
64

RPM
1800

Imp. Dia.
14 in.

gpm
613
1226
1839
2452
3065

dBA SPL
80
81
81
80
81

63
43
35
33
29
37

125
70
67
68
69
70

250
70
69
69
71
71

500
68
72
70
69
68

1K
72
73
75
73
75

2K
75
77
77
73
76

4K
73
74
75
74
76

8K
63
62
65
62
66

55

8K
69
64
64
61
66

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: 8x6-16A

10/16/2001

RPM
1200

Total
Flow Unfiltered
Imp. Dia. gpm dBA SPL
16 in.
465
77
930
78
1395
77
1860
79
2325
79

63
44
54
57
57
56

125
63
62
62
64
62

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
63
64
73
72
71
64
67
74
72
71
64
67
74
70
70
63
66
76
72
71
62
64
77
69
71

8K
57
54
54
57
59

RPM
1200

Imp. Dia.
15 in.

gpm dBA SPL


450
77
900
76
1350
78
1800
77
2250
76

63
41
42
46
49
50

125
62
62
63
62
61

250
65
64
65
66
65

500
68
69
69
67
65

1K
74
70
74
73
73

2K
67
70
71
70
67

4K
69
69
71
68
69

8K
48
47
44
49
56

RPM
1200

Imp. Dia.
14 in.

gpm dBA SPL


402
71
804
71
1206
75
1608
73
2010
71

63
39
28
42
33
39

125
60
57
52
55
53

250
63
58
58
59
56

500
62
57
61
62
63

1K
63
67
71
70
65

2K
64
65
70
64
64

4K
66
66
65
67
67

8K
54
44
57
44
44

56

50 Hz SOUND PRESSURE LEVELS

Pump size: 10x8-16H

2/10/1999

Flow
m 3/hr
319
638
958
1208

Total
Unfiltered
dBA SPL
86
89
88
87

63
55
56
56
51

125
70
71
69
65

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
77
80
81
78
75
80
84
84
80
74
80
83
84
80
70
80
83
83
78

8K
71
71
70
68

RPM
1500

Imp. Dia.
15 in

RPM
1000

Imp. Dia.
16 in

m 3/hr
228
433
675
912
1094

dBA SPL
81
80
78
82
80

63
54
53
52
46
42

125
54
48
48
48
45

250
59
60
60
49
51

500
71
72
71
68
68

1K
77
76
74
80
77

2K
76
75
72
78
76

4K
71
70
68
68
67

8K
64
62
60
58
55

RPM
1000

Imp. Dia.
15 in

m 3/hr
208
416
624
832
1008

dBA SPL
76
74
78
77
81

63
53
54
53
50
46

125
45
45
45
46
46

250
60
61
61
61
59

500
61
65
69
68
71

1K
73
71
76
74
78

2K
71
69
73
71
76

4K
66
64
63
69
69

8K
48
47
47
51
48

57

60 Hz SOUND PRESSURE LEVELS

Pump size: 10x8-16H

2/10/1999

Flow
gpm
1400
2800
4200
5300

Total
Unfiltered
dBA SPL
88
91
90
89

63
57
58
58
53

125
72
73
71
67

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
76
79
82
83
80
77
82
86
86
82
76
82
85
86
82
72
82
85
85
80

RPM
1800

Imp. Dia.
15 in

RPM
1200

Imp. Dia.
16 in

gpm
1000
1900
2960
4000
4800

dBA SPL
82
81
79
83
81

63
55
54
53
47
43

125
55
49
49
49
46

250
60
61
61
50
52

500
72
73
72
69
69

1K
78
77
75
81
78

2K
77
76
73
79
77

4K
72
71
69
69
68

8K
65
63
61
59
56

RPM
1200

Imp. Dia.
15 in

gpm
913
1825
2738
3650
4420

dBA SPL
77
75
79
78
82

63
54
55
54
51
47

125
46
46
46
47
47

250
61
62
62
62
60

500
62
66
70
69
72

1K
74
72
77
75
79

2K
72
70
74
72
77

4K
67
65
64
70
70

8K
49
48
48
52
49

58

8K
73
73
72
70

50 Hz SOUND PRESSURE LEVELS

Pump size: 10x8-17

2/10/1999

Flow
m 3/hr
0
228
456
684
849

Total
Unfiltered
dBA SPL
87
86
83
81
80

63
50
48
54
53
48

125
66
65
66
65
63

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
77
83
82
79
68
78
82
79
76
68
73
79
78
75
65
70
76
77
74
61
67
74
77
73

8K
72
69
68
64
63

RPM
1000

Imp. Dia.
17 in

RPM
1000

Imp. Dia.
15 in

m 3/hr
0
233
467
730

dBA SPL
78
79
79
78

63
51
48
46
42

125
71
65
57
60

250
67
65
65
61

500
66
67
68
66

1K
69
72
72
72

2K
73
74
74
74

4K
72
73
73
71

8K
63
65
66
64

RPM
1000

Imp. Dia.
13 in

m 3/hr
0
114
228
456
581

dBA SPL
76
78
79
79
75

63
48
48
49
48
47

125
67
66
68
68
67

250
60
62
65
63
58

500
67
68
68
66
64

1K
70
71
72
72
66

2K
70
72
75
75
70

4K
70
72
73
73
69

8K
63
64
66
64
63

59

60 Hz SOUND PRESSURE LEVELS

Pump size: 10x8-17

2/10/1999

Flow
gpm
0
1000
2000
3000
3725

Total
Unfiltered
dBA SPL
88
87
84
82
81

63
51
49
55
54
49

125
67
66
67
66
64

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
70
78
84
83
80
69
79
83
80
77
69
74
80
79
76
66
71
77
78
75
62
68
75
78
74

RPM
1200

Imp. Dia.
17 in

RPM
1200

Imp. Dia.
15 in

gpm
0
1020
2050
3200

dBA SPL
79
80
80
79

63
52
49
47
43

125
72
66
58
61

250
68
66
66
62

500
67
68
69
67

1K
70
73
73
73

2K
74
75
75
75

4K
73
74
74
72

8K
64
66
67
65

RPM
1200

Imp. Dia.
13 in

gpm
0
500
1000
2000
2550

dBA SPL
77
79
80
80
76

63
49
49
50
49
48

125
68
67
69
69
68

250
61
63
66
64
59

500
68
69
69
67
65

1K
71
72
73
73
67

2K
71
73
76
76
71

4K
71
73
74
74
70

8K
64
65
67
65
64

60

8K
73
70
69
65
64

Mark 3 Self-Priming
Durco Self-Priming pumps

61

50 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1US-6

2/10/1999

Flow
3
m /hr
7
14
21
27
32

Total
Unfiltered
dBA SPL
70
68
67
68
69

63
41
39
39
39
38

125
50
41
41
42
42

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
57
63
65
65
61
53
60
61
64
60
52
59
61
63
59
54
61
60
64
60
56
62
62
64
61

8K
56
56
53
54
55

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5 in

3
m /hr
5
9
14
18
23

dBA SPL
67
68
68
66
66

63
38
40
40
40
38

125
47
47
47
46
48

250
57
56
54
53
52

500
58
61
59
57
58

1K
61
63
64
61
61

2K
62
62
62
61
61

4K
59
61
60
59
59

8K
53
53
52
52
52

RPM
3000

Imp. Dia.
4 in

3
m /hr
5
9
14
18
23

dBA SPL
66
65
65
64
65

63
42
41
40
39
38

125
43
44
44
44
44

250
57
53
53
52
53

500
58
58
57
57
58

1K
59
59
59
59
59

2K
59
59
60
58
59

4K
59
58
58
56
56

8K
50
51
50
50
49

RPM
1500

Imp. Dia.
6 in

3
m /hr
3
7
10
14
16

dBA SPL
62
62
61
61
61

63
41
41
41
39
39

125
50
50
50
50
50

250
50
50
49
50
50

500
54
54
54
53
54

1K
56
56
55
55
55

2K
58
58
57
57
57

4K
53
51
49
49
50

8K
40
40
40
40
40

RPM
1500

Imp. Dia.
5 in

3
m /hr
2
5
7
9
11

dBA SPL
62
62
62
63
62

63
41
41
40
41
41

125
45
47
45
46
45

250
49
50
48
49
49

500
53
54
54
55
54

1K
56
56
56
56
55

2K
57
57
57
58
57

4K
52
53
52
54
54

8K
46
48
47
49
47

62

60 Hz SOUND PRESSURE LEVELS

Pump size: 1.5x1US-6

2/10/1999

Flow
gpm
30
60
90
120
140

Total
Unfiltered
dBA SPL
74
72
71
72
73

63
45
43
43
43
42

125
54
45
45
46
46

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
61
67
69
69
65
57
64
65
68
64
56
63
65
67
63
58
65
64
68
64
60
66
66
68
65

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5 in

gpm
20
40
60
80
100

dBA SPL
71
72
72
70
70

63
42
44
44
44
42

125
51
51
51
50
52

250
61
60
58
57
56

500
62
65
63
61
62

1K
65
67
68
65
65

2K
66
66
66
65
65

4K
63
65
64
63
63

8K
57
57
56
56
56

RPM
3600

Imp. Dia.
4 in

gpm
20
40
60
80
100

dBA SPL
70
69
69
68
69

63
46
45
44
43
42

125
47
48
48
48
48

250
61
57
57
56
57

500
62
62
61
61
62

1K
63
63
63
63
63

2K
63
63
64
62
63

4K
63
62
62
60
60

8K
54
55
54
54
53

RPM
1800

Imp. Dia.
6 in

gpm
15
30
45
60
70

dBA SPL
64
64
63
63
63

63
43
43
43
41
41

125
52
52
52
52
52

250
52
52
51
52
52

500
56
56
56
55
56

1K
58
58
57
57
57

2K
60
60
59
59
59

4K
55
53
51
51
52

8K
42
42
42
42
42

RPM
1800

Imp. Dia.
5 in

gpm
10
20
30
40
50

dBA SPL
64
64
64
65
64

63
43
43
42
43
43

125
47
49
47
48
47

250
51
52
50
51
51

500
55
56
56
57
56

1K
58
58
58
58
57

2K
59
59
59
60
59

4K
54
55
54
56
56

8K
48
50
49
51
49

63

8K
60
60
57
58
59

64

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5US-10A

2/10/1999

Flow
3
m /hr
11
34
46
57
64

Total
Unfiltered
dBA SPL
80
76
77
82
85

63
40
40
38
40
42

125
51
51
50
50
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
64
74
74
75
73
60
70
70
70
68
61
70
70
73
68
61
72
76
79
73
61
75
76
79
77

8K
66
61
65
71
82

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

3
m /hr
9
18
27
36
55

dBA SPL
83
84
84
83
82

63
38
38
38
38
38

125
50
50
51
50
50

250
65
62
62
62
62

500
74
74
76
75
71

1K
77
79
77
76
75

2K
79
80
80
79
79

4K
77
77
77
76
74

8K
68
70
69
67
65

RPM
3000

Imp. Dia.
8 in

3
m /hr
9
18
27
36
46

dBA SPL
76
78
78
78
77

63
38
38
40
36
36

125
51
52
51
52
52

250
62
61
61
61
61

500
71
72
71
71
70

1K
69
70
71
71
70

2K
71
73
74
72
72

4K
69
71
72
73
70

8K
61
63
64
64
62

RPM
1500

Imp. Dia.
10 in

3
m /hr
6
11
17
23
29

dBA SPL
68
67
67
67
67

63
37
42
42
44
38

125
51
51
51
51
52

250
53
52
52
52
51

500
61
60
59
60
58

1K
63
62
63
63
62

2K
63
63
62
62
62

4K
55
55
56
56
56

8K
46
46
46
47
47

RPM
1500

Imp. Dia.
9 in

3
m /hr
5
9
14
18
23

dBA SPL
72
71
71
71
70

63
40
41
40
40
40

125
50
50
50
50
50

250
56
57
56
56
56

500
67
67
66
67
66

1K
64
64
64
64
63

2K
67
64
64
64
63

4K
66
65
65
64
63

8K
56
55
55
55
53

65

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5US-10A

2/10/1999

Flow
gpm
50
150
200
250
280

Total
Unfiltered
dBA SPL
84
80
81
86
89

63
44
44
42
44
46

125
55
55
54
54
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
78
78
79
77
64
74
74
74
72
65
74
74
77
72
65
76
80
83
77
65
79
80
83
81

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
40
80
120
160
240

dBA SPL
87
88
88
87
86

63
42
42
42
42
42

125
54
54
55
54
54

250
69
66
66
66
66

500
78
78
80
79
75

1K
81
83
81
80
79

2K
83
84
84
83
83

4K
81
81
81
80
78

8K
72
74
73
71
69

RPM
3600

Imp. Dia.
8 in

gpm
40
80
120
160
200

dBA SPL
80
82
82
82
81

63
42
42
44
40
40

125
55
56
55
56
56

250
66
65
65
65
65

500
75
76
75
75
74

1K
73
74
75
75
74

2K
75
77
78
76
76

4K
73
75
76
77
74

8K
65
67
68
68
66

RPM
1800

Imp. Dia.
10 in

gpm
25
50
75
100
125

dBA SPL
70
69
69
69
69

63
39
44
44
46
40

125
53
53
53
53
54

250
55
54
54
54
53

500
63
62
61
62
60

1K
65
64
65
65
64

2K
65
65
64
64
64

4K
57
57
58
58
58

8K
48
48
48
49
49

RPM
1800

Imp. Dia.
9 in

gpm
20
40
60
80
100

dBA SPL
74
73
73
73
72

63
42
43
42
42
42

125
52
52
52
52
52

250
58
59
58
58
58

500
69
69
68
69
68

1K
66
66
66
66
65

2K
69
66
66
66
65

4K
68
67
67
66
65

8K
58
57
57
57
55

66

8K
70
65
69
75
86

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2US-10

2/10/1999

Flow
3
m /hr
29
44
66
88
111

Total
Unfiltered
dBA SPL
75
77
70
68
73

63
34
32
30
33
32

125
51
47
46
45
43

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
62
67
74
63
55
63
68
76
54
55
59
63
65
66
58
60
58
62
64
58
61
65
71
62
60

8K
49
49
44
51
61

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

m /hr
26
40
60
80
100

dBA SPL
74
70
67
65
67

63
29
15
37
38
41

125
53
51
51
52
55

250
61
61
61
60
61

500
66
64
63
57
62

1K
65
63
59
57
61

2K
71
60
58
57
54

4K
67
62
52
52
51

8K
62
59
51
47
58

RPM
3000

Imp. Dia.
8 in

m /hr
26
39
58
76
97

dBA SPL
64
64
66
64
67

63
11
23
32
33
14

125
51
53
50
50
52

250
58
59
58
58
58

500
48
49
53
53
46

1K
60
58
64
58
54

2K
57
58
58
60
62

4K
55
52
52
51
61

8K
47
42
44
47
60

RPM
1500

Imp. Dia.
10 in

m /hr
15
23
34
45
57

dBA SPL
60
59
64
64
64

63
31
23
18
20
15

125
41
39
43
43
44

250
56
55
55
54
54

500
54
56
56
58
60

1K
52
48
62
61
59

2K
51
45
42
56
51

4K
43
38
43
52
52

8K
29
30
30
28
26

RPM
1500

Imp. Dia.
9 in

m /hr
14
22
32
43
54

dBA SPL
67
67
66
67
67

63
15
18
26
18
31

125
51
50
48
48
50

250
51
50
49
48
50

500
64
64
63
63
63

1K
63
63
63
64
65

2K
49
47
46
50
48

4K
48
41
49
51
53

8K
30
30
29
33
29

67

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2US-10

2/10/1999

Flow
gpm
128
194
291
388
485

Total
Unfiltered
dBA SPL
79
81
74
72
77

63
38
36
34
37
36

125
55
51
50
49
47

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
66
71
78
67
59
67
72
80
58
59
63
67
69
70
62
64
62
66
68
62
65
69
75
66
64

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
116
176
264
352
440

dBA SPL
78
74
71
69
71

63
33
19
41
42
45

125
57
55
55
56
59

250
65
65
65
64
65

500
70
68
67
61
66

1K
69
67
63
61
65

2K
75
64
62
61
58

4K
71
66
56
56
55

8K
66
63
55
51
62

RPM
3600

Imp. Dia.
8 in

gpm
112
170
255
340
425

dBA SPL
68
68
70
68
71

63
15
27
36
37
18

125
55
57
54
54
56

250
62
63
62
62
62

500
52
43
57
57
50

1K
64
62
68
62
58

2K
61
62
62
64
66

4K
59
56
56
55
65

8K
51
46
48
51
64

RPM
1800

Imp. Dia.
10 in

gpm
66
100
149
199
249

dBA SPL
62
61
66
66
66

63
33
25
20
22
17

125
43
41
44
45
46

250
58
57
57
56
56

500
56
58
58
60
62

1K
56
50
64
63
61

2K
53
47
44
58
53

4K
45
40
45
54
54

8K
31
32
32
30
28

RPM
1800

Imp. Dia.
9 in

gpm
62
95
142
189
236

dBA SPL
69
69
68
69
69

63
17
20
28
20
33

125
53
52
50
50
52

250
53
52
51
50
52

500
66
66
65
65
65

1K
65
65
65
66
67

2K
51
49
48
52
50

4K
50
43
51
53
55

8K
32
32
31
35
31

68

8K
53
53
48
55
65

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2US-13

2/10/1999

Flow
3
m /hr
23
46
68
91
114

Total
Unfiltered
dBA SPL
78
76
76
81
88

63
39
38
38
44
44

125
65
61
60
58
59

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
70
72
67
64
68
69
72
67
64
64
69
72
68
64
73
70
76
75
74
75
79
84
83
78

8K
53
52
54
62
70

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
12.5 in

m /hr
23
46
68
91

dBA SPL
81
78
78
76

63
43
44
43
42

125
55
55
54
53

250
77
74
73
66

500
71
70
69
68

1K
74
73
73
73

2K
72
67
66
66

4K
68
64
64
64

8K
61
56
54
54

RPM
1500

Imp. Dia.
12 in

m /hr
23
46
68
91

dBA SPL
77
76
75
76

63
43
44
45
43

125
55
54
54
53

250
65
66
63
62

500
68
69
68
68

1K
72
72
72
73

2K
72
67
67
67

4K
67
65
64
64

8K
61
55
54
54

RPM
1500

Imp. Dia.
10 in

m /hr
23
46
68
91

dBA SPL
79
78
75
75

63
44
44
43
44

125
55
54
54
54

250
76
73
66
64

500
72
70
68
68

1K
73
73
72
72

2K
67
67
65
65

4K
64
64
63
63

8K
54
54
52
52

69

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2US-13

2/10/1999

Flow
gpm
100
200
300
400
500

Total
Unfiltered
dBA SPL
80
78
78
83
90

63
41
40
40
46
46

125
67
63
62
60
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
76
72
74
69
66
70
71
74
69
66
66
71
74
70
66
75
72
78
77
76
77
81
86
85
80

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
12.5 in

gpm
100
200
300
400

dBA SPL
83
80
80
78

63
45
46
45
44

125
57
57
56
55

250
79
76
75
68

500
73
72
71
70

1K
76
75
75
75

2K
74
69
68
68

4K
70
66
66
66

8K
63
58
56
56

RPM
1800

Imp. Dia.
12 in

gpm
100
200
300
400

dBA SPL
79
78
77
78

63
45
46
47
45

125
57
56
56
55

250
67
68
65
64

500
70
71
70
70

1K
74
74
74
75

2K
74
69
69
69

4K
69
67
66
66

8K
63
57
56
56

RPM
1800

Imp. Dia.
10 in

gpm
100
200
300
400

dBA SPL
81
80
77
77

63
46
46
45
46

125
57
56
56
56

250
78
75
68
68

500
74
72
70
70

1K
75
75
74
74

2K
69
69
67
67

4K
66
66
65
65

8K
56
56
54
54

70

8K
55
54
56
64
72

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3US-13

2/10/1999

Flow
3
m /hr
23
68
114
137
182

Total
Unfiltered
dBA SPL
87
83
80
81
87

63
45
40
41
40
43

125
59
53
51
51
53

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
67
77
82
83
76
65
74
79
79
72
61
71
76
75
66
61
69
75
76
75
65
77
83
82
76

8K
66
63
59
66
64

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
12 in

m /hr
46
91
137
182
205

dBA SPL
81
77
78
87
90

63
38
38
39
43
44

125
54
54
54
56
59

250
66
61
67
66
70

500
72
70
72
79
80

1K
75
73
73
83
85

2K
77
71
71
81
85

4K
72
66
65
76
81

8K
63
58
56
65
70

RPM
1500

Imp. Dia.
11 in

m /hr
23
57
91
125
171

dBA SPL
83
79
77
75
85

63
36
35
36
37
41

125
55
53
53
53
54

250
71
66
60
63
62

500
75
72
71
71
74

1K
77
73
72
71
78

2K
78
74
71
67
83

4K
73
68
66
60
75

8K
63
58
56
53
65

RPM
1500

Imp. Dia.
10 in

m /hr
23
68
91
114
137

dBA SPL
77
74
74
74
75

63
37
40
38
37
37

125
49
49
50
49
50

250
63
58
57
58
58

500
70
68
67
67
67

1K
72
72
72
71
71

2K
72
66
67
65
68

4K
67
60
60
59
65

8K
68
52
53
52
55

71

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3US-13

2/10/1999

Flow
gpm
100
300
500
600
800

Total
Unfiltered
dBA SPL
89
85
82
83
89

63
47
42
43
42
45

125
61
55
53
53
55

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
79
84
85
78
67
76
81
81
74
63
73
78
77
68
63
71
77
78
77
67
79
85
84
78

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
12 in

gpm
200
400
600
800
900

dBA SPL
83
79
80
89
92

63
40
40
41
45
46

125
56
56
56
58
61

250
68
63
69
68
72

500
74
72
74
81
82

1K
77
75
75
85
87

2K
79
73
73
83
87

4K
74
68
67
78
83

8K
65
60
58
67
72

RPM
1800

Imp. Dia.
11 in

gpm
100
250
400
550
750

dBA SPL
85
81
79
77
87

63
38
37
38
39
43

125
57
55
55
55
56

250
73
68
62
65
64

500
77
74
73
73
76

1K
79
75
74
73
80

2K
80
76
73
69
85

4K
75
70
68
62
77

8K
65
60
58
55
67

RPM
1800

Imp. Dia.
10 in

gpm
100
300
400
500
600

dBA SPL
79
76
76
76
77

63
39
42
40
39
39

125
51
51
52
51
52

250
65
60
59
60
60

500
72
70
69
69
69

1K
74
74
74
73
73

2K
74
68
69
67
70

4K
69
62
62
61
67

8K
70
54
55
54
57

72

8K
68
65
61
68
66

50 Hz SOUND PRESSURE LEVELS

Pump size: 6x4US-13

2/10/1999

Flow
3
m /hr
91
136
205
272
342

Total
Unfiltered
dBA SPL
94
92
85
79
82

63
45
43
41
43
0

125
42
45
18
55
66

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
82
88
89
87
70
80
86
87
85
64
75
81
80
77
61
69
76
73
65
63
70
79
75
72

8K
82
79
70
59
65

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
12 in

m /hr
88
133
199
266
332

dBA SPL
89
87
82
77
83

63
45
43
39
34
0

125
64
58
48
56
62

250
72
67
62
61
62

500
79
76
72
69
73

1K
86
83
78
74
81

2K
83
82
77
70
74

4K
81
79
75
65
72

8K
73
71
66
60
65

RPM
1500

Imp. Dia.
11 in

m /hr
80
121
181
242
293

dBA SPL
83
82
80
68
71

63
51
49
49
49
49

125
62
57
53
55
52

250
64
61
57
52
55

500
73
73
71
58
62

1K
76
75
76
61
63

2K
80
79
76
66
68

4K
77
75
71
57
63

8K
68
66
61
49
53

RPM
1000

Imp. Dia.
13 in

m /hr
60
90
135
181
226

dBA SPL
86
83
75
72
72

63
36
0
0
0
0

125
53
50
41
22
25

250
66
64
53
48
51

500
78
76
69
66
65

1K
81
79
72
68
70

2K
80
78
69
63
63

4K
78
75
66
59
60

8K
72
68
59
53
53

RPM
1000

Imp. Dia.
12 in

m /hr
55
83
124
165
207

dBA SPL
80
79
74
73
72

63
0
0
0
0
0

125
46
33
37
20
22

250
61
58
56
53
54

500
75
74
71
71
70

1K
76
73
68
65
66

2K
74
73
65
61
64

4K
71
69
63
61
61

8K
63
61
55
53
53

73

60 Hz SOUND PRESSURE LEVELS

Pump size: 6x4US-13

2/10/1999

Flow
gpm
400
600
900
1200
1500

Total
Unfiltered
dBA SPL
96
94
87
81
84

63
47
45
43
45
0

125
44
47
20
57
68

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
84
90
91
89
72
82
88
89
87
66
77
83
82
79
63
71
78
75
67
65
72
81
77
74

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
12 in

gpm
386
585
878
1170
1463

dBA SPL
91
89
84
79
85

63
47
45
41
36
0

125
66
60
50
58
64

250
74
69
64
63
64

500
81
78
74
71
75

1K
88
85
80
76
83

2K
85
84
79
72
76

4K
83
81
77
67
74

8K
75
73
68
62
67

RPM
1800

Imp. Dia.
11 in

gpm
351
533
799
1065
1290

dBA SPL
85
84
82
70
73

63
53
51
51
51
51

125
64
59
55
57
54

250
66
63
59
54
57

500
75
75
73
60
64

1K
78
77
78
63
65

2K
82
81
78
68
70

4K
79
77
73
59
65

8K
70
68
63
51
55

RPM
1200

Imp. Dia.
13 in

gpm
262
398
596
795
994

dBA SPL
87
84
76
73
73

63
37
0
0
0
0

125
54
51
42
23
26

250
67
65
54
49
52

500
79
77
70
67
66

1K
82
80
73
69
71

2K
81
79
70
64
64

4K
79
76
67
60
61

8K
73
69
60
54
54

RPM
1200

Imp. Dia.
12 in

gpm
240
364
546
728
910

dBA SPL
81
80
75
74
73

63
0
0
0
0
0

125
47
34
38
21
23

250
62
59
57
54
55

500
76
75
72
72
71

1K
77
74
69
66
67

2K
75
74
66
62
65

4K
72
70
64
62
62

8K
64
62
56
54
54

74

8K
84
81
72
61
67

Mark 3 Lo-Flo
Durco B73.1 metallic sealed horizontal pumps with
Lo-Flo hydraulic designs (i.e. 1K1.5x1LF-4)

75

50 Hz SOUND PRESSURE LEVELS

Pump size: 1K1.5x1LF-4

2/10/1999

Flow
3
m /hr
0
1
3
4
6

Total
Unfiltered
dBA SPL
67
66
65
68
72

63
41
42
40
42
42

125
40
42
41
41
43

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
51
60
62
62
56
51
58
63
59
55
51
59
63
53
51
51
58
63
64
57
52
63
68
65
63

8K
51
50
48
49
64

RPM
3000

Imp. Dia.
102 mm

RPM
3000

Imp. Dia.
102 mm

3
m /hr
0
0.5
2
4
5

dBA SPL
65
65
68
66
73

63
39
39
40
39
37

125
45
45
45
45
45

250
54
54
63
53
53

500
60
60
59
59
59

1K
57
57
63
62
64

2K
61
60
61
60
71

4K
54
51
49
49
65

8K
50
49
47
47
64

RPM
1500

Imp. Dia.
102 mm

3
m /hr
0
0.4
2
3
4

dBA SPL
59
59
59
59
61

63
34
40
36
36
38

125
43
41
41
40
41

250
54
55
55
56
56

500
49
49
50
51
53

1K
49
49
49
51
52

2K
53
52
52
52
54

4K
48
48
48
47
50

8K
45
45
43
44
46

RPM
1500

Imp. Dia.
102 mm

3
m /hr
0
0.3
1
2
3

dBA SPL
60
61
62
61
61

63
43
43
41
42
43

125
42
45
43
41
41

250
55
51
53
55
55

500
51
47
53
47
47

1K
51
55
58
53
51

2K
54
58
58
58
58

4K
52
45
45
51
45

8K
45
48
48
48
46

76

60 & 50 Hz SOUND PRESSURE LEVELS

Pump size: 1K1.5x1LF-4

2/10/1999

Flow
gpm
0
3
12
18
27

Total
Unfiltered
dBA SPL
71
70
69
72
76

63
45
46
44
46
46

125
44
46
45
45
47

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
55
64
66
66
60
55
62
67
63
59
55
63
67
57
55
55
62
67
68
61
56
67
72
69
67

RPM
3600

Imp. Dia.
4 in

RPM
3000

Imp. Dia.
4 in

gpm
0
2
10
17
23

dBA SPL
65
65
68
66
73

63
39
39
40
39
37

125
45
45
45
45
45

250
54
54
63
53
53

500
60
60
59
59
59

1K
57
57
63
62
64

2K
61
60
61
60
71

4K
54
51
49
49
65

8K
50
49
47
47
64

RPM
1800

Imp. Dia.
4 in

gpm
0
2
7
12
16

dBA SPL
61
61
61
61
63

63
36
42
38
38
40

125
45
43
43
42
43

250
56
57
57
58
58

500
51
51
52
53
55

1K
51
51
51
53
54

2K
55
54
54
54
56

4K
50
50
50
49
52

8K
47
47
45
46
48

RPM
1500

Imp. Dia.
4 in

gpm
0
2
6
11
14

dBA SPL
60
61
62
61
61

63
43
43
41
42
43

125
42
45
43
41
41

250
55
51
53
55
55

500
51
47
53
47
47

1K
51
55
58
53
51

2K
54
58
58
58
58

4K
52
45
45
51
45

8K
45
48
48
48
46

77

8K
55
54
52
53
68

50 Hz SOUND PRESSURE LEVELS

Pump size: 1K1.5x1LF-82

2/10/1999

Flow
3
m /hr
0
1
5
8
11

Total
Unfiltered
dBA SPL
78
78
77
76
76

63
38
38
38
37
39

125
42
42
42
42
43

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
54
66
71
74
71
55
65
72
74
72
53
60
71
74
69
54
60
71
74
67
54
60
72
73
66

8K
65
64
59
57
58

RPM
3000

Imp. Dia.
8.18 in

RPM
3000

Imp. Dia.
6 in

3
m /hr
0
1
3
6
8

dBA SPL
65
69
70
71
71

63
46
46
42
38
34

125
42
42
41
40
40

250
55
53
48
52
53

500
58
58
57
56
52

1K
62
62
62
62
63

2K
56
62
67
69
68

4K
59
65
63
65
64

8K
47
52
50
51
51

RPM
3000

Imp. Dia.
4 in

3
m /hr
0
1
3
6
8

dBA SPL
68
68
69
67
69

63
43
43
42
42
42

125
34
35
35
40
40

250
44
46
46
46
48

500
61
61
61
61
61

1K
65
59
65
61
62

2K
61
61
62
61
64

4K
59
60
60
60
64

8K
51
63
57
55
57

RPM
1500

Imp. Dia.
8.18 in

3
m /hr
0
1
2
4
5

dBA SPL
63
63
60
66
69

63
32
30
65
31
65

125
41
41
41
41
41

250
49
50
49
49
49

500
53
55
50
52
57

1K
57
57
57
60
64

2K
57
57
54
64
67

4K
58
58
48
58
51

8K
48
48
45
43
46

RPM
1500

Imp. Dia.
4 in

3
m /hr
0
0.2
1
2
3

dBA SPL
61
60
60
61
60

63
31
35
33
31
30

125
33
39
39
33
39

250
42
42
48
48
42

500
54
53
52
53
53

1K
52
54
56
57
57

2K
57
50
50
50
50

4K
54
54
54
54
54

8K
47
47
47
47
47

78

60 Hz SOUND PRESSURE LEVELS

Pump size: 1K1.5x1LF-82

2/10/1999

Flow
gpm
0
5
20
35
48

Total
Unfiltered
dBA SPL
82
82
81
80
80

63
42
42
42
41
43

125
46
46
46
46
47

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
58
70
75
78
75
59
69
76
78
76
57
64
75
78
73
58
64
75
78
71
58
64
76
77
70

RPM
3600

Imp. Dia.
8.18 in

RPM
3600

Imp. Dia.
6 in

gpm
0
4
14
25
33

dBA SPL
69
73
74
75
75

63
50
50
46
42
38

125
46
46
45
44
44

250
59
57
52
56
57

500
62
62
61
60
56

1K
66
66
66
66
67

2K
60
66
71
73
72

4K
53
69
67
69
68

8K
51
56
54
55
55

RPM
3600

Imp. Dia.
4 in

gpm
0
3
11
19
23

dBA SPL
72
72
73
71
73

63
47
47
46
46
46

125
38
39
39
44
44

250
48
50
50
50
52

500
65
65
65
65
65

1K
69
63
69
65
66

2K
65
65
66
65
68

4K
63
64
64
64
65

8K
55
67
61
59
61

RPM
1800

Imp. Dia.
8.18 in

gpm
0
3
10
18
24

dBA SPL
65
65
62
68
71

63
34
32
37
33
37

125
43
43
43
43
43

250
51
52
51
51
51

500
55
57
52
54
59

1K
59
59
59
62
66

2K
59
59
56
66
69

4K
60
60
50
60
53

8K
50
50
47
45
48

RPM
1800

Imp. Dia.
4 in

gpm
0
1
5
9
12

dBA SPL
63
62
62
63
62

63
34
37
35
33
32

125
35
41
41
35
41

250
44
44
50
50
44

500
56
55
54
55
55

1K
54
56
58
59
59

2K
59
52
52
52
52

4K
56
56
56
56
56

8K
49
49
49
49
49

79

8K
69
68
63
61
62

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x1LF-10

2/10/1999

Flow
3
m /hr
2
6
10
14

Total
Unfiltered
dBA SPL
81
83
83
88

63
38
39
37
38

125
46
48
49
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
58
68
79
76
65
58
70
72
77
72
58
71
81
78
70
61
72
86
84
76

8K
67
65
62
67

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
8 in

3
m /hr
0
1
5
9
12

dBA SPL
71
73
77
76
78

63
39
41
41
41
42

125
41
44
44
47
56

250
58
61
62
62
62

500
65
68
69
70
70

1K
67
67
69
70
70

2K
65
69
74
73
76

4K
53
54
69
66
67

8K
47
53
58
59
61

RPM
3000

Imp. Dia.
7 in

3
m /hr
0
1
5
9
12

dBA SPL
80
77
80
80
80

63
40
35
35
35
35

125
43
45
46
46
46

250
61
55
60
60
60

500
77
71
77
77
77

1K
75
74
74
74
74

2K
67
70
71
72
71

4K
64
65
67
67
68

8K
53
52
52
56
58

RPM
1500

Imp. Dia.
10 in

3
m /hr
0
1
3
5
7

dBA SPL
72
72
73
74
77

63
30
35
35
35
30

125
45
45
45
45
43

250
41
51
51
53
51

500
70
70
70
67
67

1K
63
64
64
68
72

2K
60
65
65
70
74

4K
58
51
61
64
64

8K
55
50
50
50
56

RPM
1500

Imp. Dia.
7 in

3
m /hr
0
1
3
4
6

dBA SPL
67
67
67
68
69

63
40
40
41
35
41

125
46
46
46
46
47

250
55
55
55
49
55

500
61
61
60
61
61

1K
63
63
63
63
64

2K
59
60
60
63
65

4K
54
53
55
58
58

8K
45
45
45
46
46

80

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x1LF-10

2/10/1999

Flow
gpm
7
26
46
62

Total
Unfiltered
dBA SPL
85
87
87
92

63
42
43
41
42

125
50
51
53
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
62
72
83
80
69
62
74
86
81
76
62
75
85
82
74
65
76
90
88
80

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
8 in

gpm
0
6
23
40
54

dBA SPL
75
77
81
80
82

63
43
45
45
45
46

125
45
48
48
51
60

250
62
65
66
66
66

500
69
72
73
74
74

1K
71
71
73
74
74

2K
69
73
78
77
80

4K
57
58
73
70
71

8K
51
57
62
63
65

RPM
3600

Imp. Dia.
7 in

gpm
0
6
22
39
52

dBA SPL
84
81
84
84
84

63
44
39
39
39
39

125
47
49
50
50
50

250
65
59
64
64
64

500
81
75
81
81
81

1K
79
78
78
78
78

2K
71
74
75
76
75

4K
68
69
71
71
72

8K
57
56
56
60
62

RPM
1800

Imp. Dia.
10 in

gpm
0
3
13
22
30

dBA SPL
74
74
75
76
79

63
32
37
37
37
32

125
47
47
47
47
45

250
43
53
53
55
53

500
72
72
72
69
69

1K
65
66
66
70
74

2K
62
67
67
72
76

4K
60
53
63
67
66

8K
57
52
52
52
58

RPM
1800

Imp. Dia.
7 in

gpm
0
3
11
19
26

dBA SPL
69
69
69
70
71

63
42
42
43
37
43

125
48
48
48
48
49

250
57
57
57
51
57

500
63
63
62
63
63

1K
65
65
65
65
66

2K
61
62
62
65
67

4K
56
55
57
60
60

8K
47
47
47
48
48

81

8K
71
69
66
71

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5LF-13

2/10/1999

Flow
3
m /hr
5
23
34
46
57

Total
Unfiltered
dBA SPL
83
82
84
89
98

63
44
37
41
41
42

125
52
43
50
39
63

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
75
79
78
75
67
73
79
76
73
66
73
78
80
76
71
77
83
85
81
84
87
91
94
90

8K
71
68
70
75
85

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
12 in

3
m /hr
4
19
29
39
49

dBA SPL
80
77
79
81
92

63
40
32
16
38
39

125
48
53
48
55
57

250
67
64
65
65
74

500
71
69
70
71
81

1K
71
73
74
74
85

2K
76
65
76
78
89

4K
75
72
69
74
84

8K
64
58
59
69
78

RPM
3000

Imp. Dia.
11 in

3
m /hr
4
18
27
36
46

dBA SPL
71
72
75
79
88

63
36
34
37
38
39

125
48
55
45
51
54

250
62
66
66
68
72

500
68
67
69
70
78

1K
51
53
67
72
81

2K
53
51
68
75
85

4K
66
67
68
63
80

8K
60
60
60
68
75

RPM
1500

Imp. Dia.
13 in

3
m /hr
2
11
17
23
29

dBA SPL
70
71
71
78
86

63
0
34
39
32
35

125
43
45
44
43
53

250
61
57
59
61
70

500
64
64
64
66
77

1K
63
64
66
71
79

2K
63
67
66
75
83

4K
61
61
61
70
79

8K
55
49
44
61
72

RPM
1500

Imp. Dia.
12 in

3
m /hr
2
10
15
19
24

dBA SPL
67
72
70
70
79

63
33
27
12
34
27

125
40
39
41
42
44

250
58
56
56
58
61

500
61
61
63
64
70

1K
61
67
65
65
72

2K
61
69
66
66
76

4K
57
63
58
58
70

8K
32
43
35
40
64

82

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5LF-13

2/10/1999

Flow
gpm
20
100
150
200
250

Total
Unfiltered
dBA SPL
87
86
88
93
102

63
48
41
45
45
46

125
56
47
54
43
67

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
79
83
82
79
71
77
83
80
77
70
77
82
84
80
75
81
87
89
85
88
91
95
98
94

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
12 in

gpm
17
85
128
170
213

dBA SPL
84
81
83
85
96

63
44
36
20
42
43

125
52
57
52
59
61

250
71
68
69
69
78

500
75
73
74
75
85

1K
75
77
78
78
89

2K
80
69
80
82
93

4K
79
76
73
78
88

8K
68
62
63
73
82

RPM
3600

Imp. Dia.
11 in

gpm
16
80
120
160
200

dBA SPL
75
76
79
84
92

63
40
38
41
42
43

125
52
59
49
55
58

250
66
70
70
72
76

500
72
71
73
74
82

1K
55
67
71
76
85

2K
57
55
72
79
89

4K
70
71
72
77
84

8K
64
64
64
72
79

RPM
1800

Imp. Dia.
13 in

gpm
10
50
75
100
125

dBA SPL
72
73
73
80
88

63
0
36
41
34
37

125
45
47
46
45
55

250
63
59
61
63
72

500
66
66
66
68
79

1K
65
66
68
73
81

2K
65
69
68
77
85

4K
63
63
63
72
81

8K
57
51
46
63
74

RPM
1800

Imp. Dia.
12 in

gpm
9
43
64
85
106

dBA SPL
69
74
72
72
81

63
35
29
14
36
29

125
42
41
43
44
46

250
60
58
58
60
63

500
63
63
65
66
72

1K
63
69
67
67
74

2K
63
71
68
68
78

4K
59
65
60
60
72

8K
34
45
37
42
66

83

8K
75
72
74
79
89

Mark 3 In-Line
Durco B73.2 metallic sealed vertical pumps

84

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5V-6

7/17/2000

Flow
3
m /hr
2
5
10
19
24

Total
Unfiltered
dBA SPL
72
72
76
73
74

63
48
48
48
48
48

125
45
40
40
38
43

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
58
67
62
68
65
57
67
62
69
65
48
66
69
73
69
53
60
66
70
66
58
65
70
68
66

8K
54
57
58
58
61

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5 in

3
m /hr
2
5
9
18
22

dBA SPL
70
72
73
72
66

63
47
48
47
48
47

125
36
41
43
43
44

250
60
59
58
59
46

500
65
65
67
66
59

1K
62
65
64
67
63

2K
63
67
69
67
57

4K
62
62
65
62
46

8K
49
50
51
55
57

RPM
3000

Imp. Dia.
4 in

3
m /hr
1
3
6
13
16

dBA SPL
67
71
69
71
72

63
48
48
48
49
49

125
47
47
46
48
48

250
54
52
54
57
58

500
61
60
58
58
61

1K
65
69
59
69
69

2K
55
63
67
62
67

4K
49
61
61
60
64

8K
52
44
53
54
57

RPM
1500

Imp. Dia.
6 in

3
m /hr
1
3
6
12
16

dBA SPL
68
70
70
70
70

63
46
48
47
47
47

125
44
44
44
45
45

250
47
47
46
46
42

500
51
53
48
52
50

1K
68
70
70
70
70

2K
48
53
52
54
52

4K
51
49
48
50
51

8K
45
38
27
45
29

RPM
1500

Imp. Dia.
5 in

3
m /hr
1
2
5
10
13

dBA SPL
69
70
70
69
70

63
44
47
45
46
47

125
43
44
44
43
41

250
48
51
50
46
49

500
47
53
57
56
59

1K
69
70
70
68
69

2K
51
50
56
54
61

4K
54
51
54
47
57

8K
46
46
46
48
43

85

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5V-6


7/17/2000
Flow
gpm
10
25
50
100
125

Total
Unfiltered
dBA SPL
77
76
79
80
80

63
49
47
46
48
49

125
51
47
50
42
45

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
69
68
72
68
69
45
56
73
71
67
70
76
73
70
55
63
75
76
73
58
70
75
77
73

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5 in

gpm
10
22
45
90
112

dBA SPL
75
79
79
78
80

63
44
39
46
46
48

125
49
52
47
48
47

250
61
64
64
64
56

500
61
62
69
68
69

1K
73
79
77
76
78

2K
68
66
70
71
74

4K
64
64
67
68
69

8K
53
56
57
62
63

RPM
3600

Imp. Dia.
4 in

gpm
8
20
38
75
95

dBA SPL
74
72
75
74
76

63
49
48
48
49
48

125
49
51
48
44
47

250
54
56
57
60
56

500
64
64
68
68
65

1K
73
68
69
69
74

2K
53
66
70
67
69

4K
62
63
63
65
66

8K
50
50
52
57
60

RPM
1800

Imp. Dia.
6 in

gpm
7
20
35
70
85

dBA SPL
62
66
63
67
63

63
46
46
47
47
47

125
49
44
46
43
42

250
46
46
42
50
51

500
58
56
58
60
58

1K
59
64
61
65
59

2K
49
52
54
55
53

4K
42
49
47
52
51

8K
44
47
45
45
47

RPM
1800

Imp. Dia.
5 in

gpm
5
15
30
60
72

dBA SPL
61
63
62
61
63

63
44
44
47
45
43

125
41
42
44
43
42

250
52
50
50
50
48

500
58
57
57
57
46

1K
49
60
57
57
62

2K
52
55
55
44
51

4K
54
53
52
43
53

8K
51
50
49
44
48

86

8K
63
61
58
61
64

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-7

7/24/2000
Flow
m3/hr
6
14
27
41
55
66

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
70
74
73
74
74
72

63
47
48
48
49
48
47

125
43
43
34
48
51
48

250
62
61
63
62
60
63

500
66
67
67
67
69
68

1K
63
69
68
71
69
63

2K
61
69
68
70
70
67

4K
53
62
61
56
57
43

8K
59
56
53
51
53
52

m3/hr
5
11
23
34
45
55

dBA SPL
70
73
73
72
74
68

63
42
44
44
37
38
41

125
40
45
44
45
44
47

250
56
57
57
56
58
56

500
64
65
66
65
67
65

1K
68
70
69
67
67
63

2K
60
65
67
68
70
50

4K
58
61
61
60
64
57

8K
52
50
53
52
54
49

Imp. Dia.
5 in

m3/hr
3
8
17
25
33
40

dBA SPL
70
72
72
69
70
72

63
44
47
46
47
37
44

125
44
45
47
46
43
45

250
54
55
56
56
54
56

500
66
66
66
65
65
65

1K
67
71
70
64
67
70

2K
44
51
54
58
56
60

4K
53
55
53
57
58
58

8K
42
50
50
53
51
52

RPM
1500

Imp. Dia.
7 in

m3/hr
3
7
14
20
27
33

dBA SPL
72
73
73
72
71
72

63
44
45
46
45
46
44

125
46
40
43
40
32
40

250
49
38
45
45
43
44

500
49
49
58
59
56
58

1K
71
72
72
71
71
71

2K
58
48
53
56
52
47

4K
53
47
52
56
53
54

8K
51
48
52
50
44
47

RPM
1500

Imp. Dia.
6 in

m3/hr
2
6
11
17
23
27

dBA SPL
67
69
69
66
69
68

63
39
36
36
34
37
36

125
37
41
40
38
42
39

250
36
42
42
43
47
43

500
55
55
55
50
58
55

1K
66
69
68
65
69
67

2K
56
54
55
54
55
52

4K
53
53
53
54
52
51

8K
47
43
46
46
38
46

RPM
3000

Imp. Dia.
7 in

RPM
3000

Imp. Dia.
6 in

RPM
3000

87

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-7

7/24/2000

Flow
gpm
30
70
145
220
290
350

Total
Unfiltered
dBA SPL
78
78
79
79
78
79

63
49
47
47
48
48
47

125
43
47
43
46
49
40

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
50
74
75
59
61
56
73
75
68
67
58
75
77
68
60
61
73
75
71
63
66
73
75
70
65
64
73
77
56
56

RPM
3600

Imp. Dia.
7 in

RPM
3600

Imp. Dia.
6 in

gpm
25
60
115
175
230
275

dBA SPL
79
79
78
76
78
79

63
32
34
38
31
41
35

125
47
45
47
44
48
39

250
53
54
59
60
62
63

500
74
73
73
72
74
74

1K
76
76
75
74
74
76

2K
70
71
65
67
68
68

4K
59
66
61
57
60
57

8K
54
57
55
55
57
57

RPM
3600

Imp. Dia.
5 in

gpm
20
45
90
135
175
210

dBA SPL
77
78
77
78
79
79

63
45
46
46
45
42
45

125
48
46
43
40
47
38

250
55
55
56
56
56
55

500
72
72
72
72
72
73

1K
76
76
75
76
78
77

2K
60
65
67
68
69
69

4K
58
62
62
63
63
61

8K
52
51
54
54
55
55

RPM
1800

Imp. Dia.
7 in

gpm
15
35
75
110
145
174

dBA SPL
68
66
68
67
68
67

63
42
41
37
38
38
29

125
41
43
42
44
44
45

250
50
50
50
50
51
50

500
59
57
58
57
57
57

1K
66
63
66
66
66
65

2K
58
58
58
57
57
58

4K
57
56
56
56
55
55

8K
52
53
54
53
52
53

RPM
1800

Imp. Dia.
6 in

gpm
12
30
60
90
120
145

dBA SPL
69
67
68
68
67
68

63
36
35
37
27
32
37

125
43
42
40
42
38
40

250
48
46
46
46
45
49

500
58
57
56
53
57
55

1K
64
58
62
63
60
63

2K
65
62
64
63
62
64

4K
63
63
62
62
62
63

8K
54
52
51
55
53
55

88

8K
60
58
50
52
55
58

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5V-8

7/17/2000
Flow
m3/hr
3
7
14
27
33

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
72
72
77
73
75

63
48
48
48
48
49

125
45
41
42
41
44

250
59
56
52
55
57

500
67
66
67
63
66

1K
60
64
71
67
71

2K
68
68
73
69
69

4K
65
64
69
66
66

8K
55
57
57
57
61

m3/hr
2
6
12
24
28

dBA SPL
71
72
73
72
67

63
48
50
48
48
45

125
38
43
44
45
39

250
59
60
58
60
42

500
66
65
67
66
64

1K
63
65
66
66
62

2K
65
67
70
66
61

4K
62
62
65
63
38

8K
48
49
53
53
50

Imp. Dia.
6 in

m3/hr
2
6
10
20
25

dBA SPL
70
71
71
71
72

63
49
49
49
49
49

125
48
48
47
48
48

250
53
51
53
58
59

500
63
62
65
62
64

1K
68
68
65
68
68

2K
58
64
67
63
66

4K
52
60
61
60
64

8K
49
49
49
51
57

RPM
1500

Imp. Dia.
8 in

m3/hr
1
3
7
14
16

dBA SPL
69
69
70
70
70

63
47
47
47
48
47

125
42
43
44
44
42

250
46
45
45
47
44

500
52
51
48
52
51

1K
69
69
70
70
69

2K
51
52
54
53
54

4K
47
48
49
50
51

8K
42
41
40
42
46

RPM
1500

Imp. Dia.
7 in

m3/hr
1
3
6
12
15

dBA SPL
69
70
70
68
70

63
44
46
44
46
46

125
43
44
44
41
42

250
47
50
49
47
48

500
47
54
57
56
59

1K
69
70
69
68
69

2K
53
49
56
53
61

4K
54
51
54
43
57

8K
47
44
46
48
46

RPM
3000

Imp. Dia.
8 in

RPM
3000

Imp. Dia.
7 in

RPM
3000

89

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x1.5V-8

7/17/2000

Flow
gpm
15
35
75
145
175

Total
Unfiltered
dBA SPL
77
77
78
78
80

63
49
49
48
49
50

125
51
51
49
43
48

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
69
68
72
68
71
64
68
72
70
68
67
74
74
70
58
66
70
75
72
59
70
74
76
73

RPM
3600

Imp. Dia.
8 in

RPM
3600

Imp. Dia.
7 in

gpm
12
30
60
120
145

dBA SPL
76
80
79
79
80

63
47
40
46
46
48

125
50
51
48
47
47

250
63
64
64
64
57

500
66
67
69
68
70

1K
74
79
78
76
78

2K
68
68
70
72
74

4K
66
65
68
69
69

8K
55
54
56
61
63

RPM
3600

Imp. Dia.
6 in

gpm
10
25
55
100
130

dBA SPL
74
74
76
74
76

63
50
49
48
48
48

125
49
52
48
46
46

250
53
57
57
60
51

500
66
66
68
67
68

1K
72
71
73
71
73

2K
62
66
70
67
70

4K
63
62
65
64
67

8K
45
43
49
57
60

RPM
1800

Imp. Dia.
8 in

gpm
7
20
35
70
85

dBA SPL
64
64
65
68
62

63
47
46
47
47
47

125
42
43
44
43
43

250
36
43
45
49
50

500
57
58
57
59
58

1K
62
62
63
66
56

2K
51
52
54
56
54

4K
44
48
47
51
50

8K
48
45
41
46
45

RPM
1800

Imp. Dia.
7 in

gpm
5
15
30
60
72

dBA SPL
62
64
63
62
64

63
45
44
46
44
42

125
42
42
42
44
41

250
52
50
49
49
46

500
57
59
58
57
50

1K
55
61
58
58
62

2K
52
53
52
44
50

4K
54
52
52
40
52

8K
50
50
49
45
47

90

8K
63
63
59
63
65

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5V-82

3/20/2003
Flow
m3/hr

RPM
3000

Imp. Dia.
8.25"

RPM
3000

Imp. Dia.
7"

m3/hr

RPM
3000

Imp. Dia.
4"

m3/hr

RPM
1500

Imp. Dia.
8.25"

m3/hr

RPM
1500

Imp. Dia.
7"

m3/hr

4
21
32
42
46

4
18
27
36
40

2
9
15
18
20

2
11
16
22
24

2
9
14
18
20

Total
Unfiltered
dBA SPL
73
71
67
69
72

63
35
35
35
35
35

125
48
50
49
50
50

dBA SPL
66
70
67
68
69

63
42
42
43
42
43

125
34
42
41
39
40

250
47
52
57
58
61

500
62
61
55
58
62

1K
61
66
64
65
64

2K
58
60
61
63
63

4K
53
64
51
57
58

8K
40
50
49
47
55

dBA SPL
68
67
70
67
67

63
35
35
35
35
35

125
47
43
64
48
47

250
47
52
41
52
49

500
62
61
64
62
63

1K
63
63
65
62
62

2K
57
55
57
55
56

4K
61
60
61
61
60

8K
52
54
54
53
51

dBA SPL
59
59
59
60
59

63
35
35
35
35
35

125
42
37
37
36
36

250
48
45
46
46
44

500
47
47
47
48
49

1K
55
55
55
56
55

2K
53
52
52
54
52

4K
47
48
51
49
47

8K
51
51
51
53
52

dBA SPL
62
62
61
62
62

63
35
35
35
35
35

125
35
38
35
36
35

250
47
47
47
47
47

500
53
53
53
54
53

1K
58
58
58
59
57

2K
54
55
54
56
54

4K
50
49
49
50
51

8K
54
51
53
51
55

91

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
63
60
66
66
68
60
60
67
66
55
56
55
64
58
60
53
50
65
64
61
54
60
69
68
58

8K
62
49
52
53
51

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5V-82

3/20/2003
Flow
gpm
69
115
172
230
253

Total
Unfiltered
dBA SPL
79
78
79
79
79

63
52
54
54
53
53

125
51
50
55
52
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
61
69
73
74
74
63
62
73
73
72
64
58
74
75
71
64
69
74
74
72
64
66
74
74
72

RPM
3600

Imp. Dia.
8.25"

RPM
3600

Imp. Dia.
7"

gpm
59
98
147
197
216

dBA SPL
76
75
74
75
77

63
57
57
57
55
56

125
51
49
50
49
52

250
51
39
54
52
51

500
70
69
67
71
72

1K
73
71
70
70
73

2K
70
68
68
68
71

4K
61
64
63
63
68

8K
53
53
57
57
61

RPM
3600

Imp. Dia.
4"

gpm
27
42
63
85
93

dBA SPL
80
80
80
80
79

63
57
57
56
57
57

125
50
51
51
49
49

250
53
56
57
55
53

500
66
67
68
67
66

1K
75
74
74
74
73

2K
75
76
75
76
75

4K
73
73
73
73
73

8K
67
68
68
68
68

RPM
1800

Imp. Dia.
8.25"

gpm
11
58
87
116
127

dBA SPL
60
63
60
59
59

63
35
35
35
35
35

125
52
51
40
38
43

250
50
47
41
42
48

500
43
51
37
46
48

1K
55
60
58
56
56

2K
53
56
55
52
51

4K
38
51
48
49
47

8K
52
48
50
46
49

RPM
1800

Imp. Dia.
7"

gpm
10
49
75
98
107

dBA SPL
62
62
63
61
61

63
35
35
35
35
35

125
31
34
31
36
31

250
47
47
46
46
45

500
47
43
48
43
43

1K
58
58
58
58
58

2K
55
54
54
53
55

4K
56
56
55
52
54

8K
51
53
57
53
51

92

8K
67
62
62
64
66

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-10

6/7/2000

Flow
3
m /hr
7
18
36
53
71
85

Total
Unfiltered
dBA SPL
80
79
81
82
81
81

63
39
43
43
43
43
43

125
54
51
48
48
47
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
69
72
75
73
72
70
62
74
72
68
72
76
78
71
64
74
76
78
74
60
72
75
78
74
60
73
75
77
73

8K
65
65
62
64
64
65

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

3
m /hr
7
16
32
49
65
78

dBA SPL
77
79
81
82
81
81

63
47
47
49
46
48
49

125
48
49
44
47
47
50

250
63
61
59
59
59
59

500
65
65
71
74
73
73

1K
75
76
79
78
77
77

2K
70
73
74
76
76
77

4K
65
69
69
72
72
71

8K
57
59
57
61
61
62

RPM
3000

Imp. Dia.
8 in

3
m /hr
6
14
28
43
57
69

dBA SPL
73
77
77
79
80
80

63
47
46
47
46
47
47

125
48
47
46
49
51
51

250
43
51
58
58
57
60

500
66
65
68
71
70
71

1K
70
71
73
75
76
75

2K
68
73
73
75
76
75

4K
64
70
68
69
70
70

8K
55
59
57
58
61
61

RPM
1500

Imp. Dia.
10 in

3
m /hr
4
10
19
29
38
45

dBA SPL
69
70
69
71
71
70

63
42
43
42
43
43
41

125
44
34
40
40
42
41

250
52
52
51
50
50
52

500
51
56
37
55
57
46

1K
69
68
68
70
69
68

2K
42
62
62
64
64
62

4K
53
58
59
61
59
57

8K
48
49
49
50
51
49

RPM
1500

Imp. Dia.
9 in

3
m /hr
3
8
17
25
33
40

dBA SPL
68
68
68
68
66
66

63
48
47
47
47
48
47

125
48
44
44
42
45
47

250
51
50
50
49
49
49

500
50
49
46
48
52
46

1K
67
68
68
67
66
65

2K
59
55
52
50
48
56

4K
53
56
50
55
47
53

8K
47
47
46
47
39
39

93

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-10

6/7/2000

Flow
gpm
38
96
192
288
384
461

Total
Unfiltered
dBA SPL
82
83
83
82
81
83

63
39
42
41
40
45
43

125
53
49
50
49
50
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
74
68
78
78
59
73
72
79
78
61
73
76
79
75
61
74
71
78
75
63
74
71
77
74
64
75
75
78
76

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
35
88
175
263
350
420

dBA SPL
81
80
81
82
80
80

63
48
47
48
49
50
48

125
53
51
49
50
49
50

250
62
61
62
63
63
64

500
72
71
72
73
73
73

1K
75
74
75
75
69
71

2K
77
76
78
78
77
76

4K
73
73
73
75
73
73

8K
67
64
63
64
65
66

RPM
3600

Imp. Dia.
8 in

gpm
31
78
155
233
310
372

dBA SPL
80
78
81
81
82
81

63
46
42
44
46
44
44

125
53
50
50
49
50
51

250
57
56
58
60
64
64

500
64
69
71
73
73
74

1K
78
73
76
74
75
72

2K
73
73
77
78
78
77

4K
70
71
71
74
74
73

8K
63
61
62
65
66
67

RPM
1800

Imp. Dia.
10 in

gpm
20
50
100
150
200
240

dBA SPL
73
74
75
77
75
76

63
47
47
47
46
47
47

125
50
43
44
46
48
49

250
57
54
55
59
62
65

500
60
62
57
64
64
64

1K
68
69
71
71
70
70

2K
69
70
71
73
71
71

4K
66
66
67
69
68
68

8K
57
56
57
59
58
58

RPM
1800

Imp. Dia.
9 in

gpm
18
44
88
132
176
211

dBA SPL
62
71
71
72
73
72

63
46
47
49
47
48
48

125
44
46
50
43
46
47

250
49
51
53
53
55
53

500
51
58
48
51
56
58

1K
57
69
68
69
71
70

2K
55
66
66
67
66
65

4K
54
60
61
61
62
61

8K
48
45
42
39
52
38

94

8K
71
70
67
66
67
71

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3V-10

6/2/2000
Flow
m3/h

RPM
3000

Imp. Dia.
10"

RPM
3000

Imp. Dia.
8"

m3/h

RPM
3000

Imp. Dia.
6"

m3/h

RPM
1500

Imp. Dia.
10"

m3/h

RPM
1500

Imp. Dia.
8"

m3/h

14
34
68
102
136
164

10
25
50
75
100
120

7
17
34
51
68
82

7
20
34
51
68
82

5
12
25
37
50
60

Total
Unfiltered
dBA SPL
85
84
81
78
79
80

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
73
77
81
78
73
69
76
81
76
59
70
72
79
74
52
69
66
75
71
73
69
68
75
71
73
71
71
76
72

63
49
48
49
49
49
49

125
55
53
50
51
44
50

dBA SPL
74
74
76
78
76
74

63
40
42
37
39
35
18

125
51
51
43
48
50
48

250
52
53
56
62
52
63

500
55
55
67
70
67
61

1K
71
70
69
69
65
69

2K
70
71
73
75
73
70

4K
65
65
67
69
68
66

8K
56
58
59
61
61
60

dBA SPL
69
72
73
75
76
74

63
36
35
36
38
29
35

125
50
48
50
52
54
54

250
49
49
54
64
61
54

500
53
50
56
61
60
55

1K
63
69
68
72
74
71

2K
64
67
69
70
70
68

4K
63
63
64
65
65
64

8K
57
57
58
60
61
60

dBA SPL
65
68
69
70
67
64

63
42
36
46
44
39
42

125
40
41
42
42
36
40

250
50
52
50
51
51
49

500
53
51
51
60
48
57

1K
64
67
67
66
65
62

2K
43
62
65
65
63
56

4K
49
48
55
57
53
50

8K
46
30
39
43
43
40

dBA SPL
61
65
63
63
66
65

63
29
37
37
37
37
37

125
43
38
36
38
36
43

250
42
42
38
42
39
41

500
53
49
47
51
52
55

1K
60
64
63
63
65
64

2K
49
44
44
49
47
51

4K
37
47
46
49
46
43

8K
45
40
43
45
41
27

95

8K
70
68
66
63
62
67

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3V-10

6/2/2000
Flow
gpm
75
188
375
563
750
900

Total
Unfiltered
dBA SPL
90
88
83
81
84
87

63
51
51
54
53
55
53

125
58
56
54
53
50
38

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
78
83
86
83
72
78
80
85
81
69
73
65
80
77
67
73
71
78
75
66
75
77
80
77
68
79
80
84
80

RPM
3600

Imp. Dia.
10"

RPM
3600

Imp. Dia.
8"

gpm
55
138
275
413
550
660

dBA SPL
78
78
81
81
78
77

63
51
49
50
49
49
50

125
56
55
51
53
52
50

250
63
60
61
63
65
64

500
52
65
68
71
65
66

1K
74
73
75
75
70
65

2K
73
74
78
76
75
74

4K
70
70
71
73
72
72

8K
62
63
64
68
65
66

RPM
3600

Imp. Dia.
6"

gpm
37
93
185
278
370
450

dBA SPL
74
76
79
81
77
80

63
55
56
56
57
56
56

125
52
52
53
53
52
53

250
57
59
60
60
63
54

500
63
65
69
71
69
68

1K
64
72
76
78
72
78

2K
72
72
74
74
73
72

4K
66
67
68
69
68
68

8K
61
60
61
64
65
65

RPM
1800

Imp. Dia.
10"

gpm
38
94
188
282
375
450

dBA SPL
78
73
71
72
72
70

63
46
45
47
46
46
47

125
48
44
47
51
48
46

250
56
54
61
63
65
61

500
66
62
62
66
64
61

1K
73
68
59
57
58
61

2K
75
70
69
70
69
66

4K
70
66
61
63
62
62

8K
57
54
52
37
47
47

RPM
1800

Imp. Dia.
8"

gpm
28
70
140
210
280
336

dBA SPL
82
71
70
71
72
70

63
50
38
37
37
37
30

125
62
45
47
45
43
41

250
71
44
54
42
49
48

500
72
48
47
49
44
51

1K
78
51
51
58
67
52

2K
77
69
68
70
70
69

4K
72
66
64
64
64
63

8K
62
44
43
38
44
42

96

8K
76
73
70
68
72
74

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5V-13

3/20/2003
Flow
m3/hr

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
12 in

m3/hr

RPM
3000

Imp. Dia.
9 in

m3/hr

RPM
1500

Imp. Dia.
13 in

m3/hr

RPM
1500

Imp. Dia.
12 in

m3/hr

8
42
63
84
93

7
36
55
73
80

5
28
41
55
60

4
20
31
41
45

4
18
27
36
40

Total
Unfiltered
dBA SPL
85
81
81
82
84

63
0
0
0
0
0

125
48
44
44
37
51

dBA SPL
81
75
79
80
80

63
0
0
39
0
40

125
41
49
45
34
46

250
68
58
68
72
72

500
72
65
68
69
70

1K
78
69
74
74
75

2K
74
66
75
75
75

4K
72
72
73
72
73

8K
67
63
60
58
68

dBA SPL
72
75
76
78
77

63
35
35
39
35
35

125
36
45
42
41
45

250
54
58
60
60
60

500
61
61
67
65
65

1K
68
71
64
75
72

2K
67
69
73
72
73

4K
63
69
69
71
70

8K
57
51
68
69
69

dBA SPL
70
69
71
70
70

63
0
0
0
0
0

125
61
58
56
49
48

250
55
41
50
53
48

500
56
57
53
60
58

1K
64
55
58
62
60

2K
61
60
56
65
64

4K
54
62
50
57
58

8K
67
66
70
66
67

dBA SPL
61
66
63
68
66

63
0
0
0
0
0

125
58
55
52
46
49

250
49
47
47
54
54

500
49
57
54
52
52

1K
53
63
59
56
58

2K
52
57
56
56
53

4K
52
54
55
53
52

8K
48
54
53
67
63

97

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
74
80
80
79
53
70
76
76
73
69
70
74
77
75
73
71
76
78
75
73
72
78
80
76

8K
72
63
65
65
68

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x1.5V-13

3/20/2003
Flow
gpm
138
230
345
460
506

Total
Unfiltered
dBA SPL
87
87
87
88
90

63
46
47
47
47
48

125
51
54
44
41
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
78
72
83
80
78
74
74
83
82
80
69
74
84
82
79
65
75
85
83
81
68
76
87
85
82

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
12 in

gpm
126
210
315
420
462

dBA SPL
81
84
85
84
85

63
46
46
47
47
46

125
49
49
51
42
50

250
67
66
62
59
60

500
67
72
73
73
73

1K
77
80
81
80
81

2K
74
80
80
79
80

4K
71
75
77
77
78

8K
69
62
63
59
67

RPM
3600

Imp. Dia.
9 in

gpm
97
162
243
325
357

dBA SPL
76
78
78
78
78

63
39
39
37
35
41

125
47
40
42
41
43

250
61
62
64
58
64

500
61
68
66
68
67

1K
71
71
71
67
70

2K
70
74
75
75
74

4K
73
71
72
74
74

8K
57
52
60
59
60

RPM
1800

Imp. Dia.
13 in

gpm
24
118
176
235
259

dBA SPL
74
75
74
74
73

63
0
41
0
0
0

125
56
42
41
53
56

250
66
59
50
60
62

500
58
58
62
60
63

1K
67
58
68
67
68

2K
66
68
69
68
67

4K
62
63
59
58
60

8K
69
73
70
71
61

RPM
1800

Imp. Dia.
12 in

gpm
22
110
165
220
242

dBA SPL
68
68
66
72
72

63
0
0
0
0
0

125
45
0
0
38
47

250
63
45
47
57
59

500
49
60
54
59
47

1K
63
63
60
67
68

2K
59
64
58
68
68

4K
51
58
60
59
59

8K
58
60
60
58
65

98

8K
73
61
59
71
76

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-13

8/4/2000
Flow
m3/hr
14
32
64
127
136

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
89
87
84
83
90

63
48
46
47
43
47

125
49
51
46
48
49

250
68
67
67
68
72

500
72
69
71
66
75

1K
81
79
75
74
83

2K
85
85
80
80
86

4K
83
81
79
76
83

8K
75
74
71
70
78

m3/hr
10
25
51
102
123

dBA SPL
79
81
82
80
82

63
38
33
44
42
44

125
50
41
43
39
38

250
68
69
66
69
70

500
60
66
61
62
62

1K
72
76
75
74
75

2K
75
76
78
76
78

4K
73
76
75
74
75

8K
69
69
68
66
70

Imp. Dia.
11 in

m3/hr
10
25
49
98
117

dBA SPL
78
80
80
79
81

63
39
43
45
42
42

125
50
49
31
45
47

250
67
66
63
65
66

500
67
65
66
68
68

1K
75
73
73
72
73

2K
71
76
76
75
77

4K
69
75
74
73
77

8K
64
59
65
65
70

RPM
1500

Imp. Dia.
13 in

m3/hr
7
17
33
66
79

dBA SPL
73
72
72
72
72

63
44
47
33
42
48

125
49
43
42
49
48

250
52
48
52
59
61

500
55
62
60
64
63

1K
65
63
67
65
66

2K
69
67
69
68
68

4K
68
68
62
63
63

8K
61
60
55
55
55

RPM
1500

Imp. Dia.
12 in

m3/hr
6
14
27
52
62

dBA SPL
65
70
71
73
72

63
46
44
41
43
43

125
37
38
34
44
46

250
44
42
47
62
63

500
49
55
57
59
61

1K
62
66
66
69
68

2K
58
65
66
68
67

4K
58
61
62
63
62

8K
56
58
61
57
62

RPM
3000

Imp. Dia.
13 in

RPM
3000

Imp. Dia.
12 in

RPM
3000

99

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x2V-13

8/4/2000

Flow
gpm
60
145
290
440
580
610

Total
Unfiltered
dBA SPL
93
91
89
85
86
94

63
50
48
46
49
50
49

125
53
53
42
50
53
52

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
82
85
89
87
70
75
83
87
85
69
73
81
84
85
67
71
79
81
79
69
75
81
82
79
76
80
89
90
86

RPM
3600

Imp. Dia.
13 in

RPM
3600

Imp. Dia.
12 in

gpm
55
140
275
550
605

dBA SPL
83
83
84
86
92

63
52
52
51
52
50

125
52
48
40
48
48

250
63
63
59
68
71

500
56
72
73
73
79

1K
78
77
77
79
88

2K
79
79
80
82
87

4K
76
77
78
79
84

8K
74
73
72
72
78

RPM
3600

Imp. Dia.
11 in

gpm
50
130
260
510
615

dBA SPL
81
81
81
82
89

63
52
51
49
49
49

125
51
50
44
49
43

250
72
72
68
66
72

500
70
67
70
69
74

1K
75
73
69
73
81

2K
77
78
78
79
86

4K
73
75
76
76
81

8K
67
66
68
69
77

RPM
1800

Imp. Dia.
13 in

gpm
35
90
175
350
420

dBA SPL
78
76
76
77
77

63
46
40
45
47
48

125
57
55
45
48
51

250
56
51
54
56
53

500
43
63
66
67
66

1K
71
63
71
72
70

2K
74
73
73
73
73

4K
73
72
69
68
70

8K
64
63
60
56
62

RPM
1800

Imp. Dia.
12 in

gpm
30
70
140
280
340

dBA SPL
74
77
75
76
75

63
39
44
37
44
45

125
59
58
54
49
49

250
56
56
59
62
61

500
58
63
60
65
61

1K
68
72
69
70
70

2K
69
72
72
73
71

4K
67
70
66
67
66

8K
60
59
59
63
62

100

8K
80
79
77
73
72
80

50 Hz SOUND PRESSURE LEVELS

Pump size: 4x3V-13

9/19/2000
Flow
m3/hr
20
50
100
200
220

Total
Unfiltered

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa

dBA SPL
85
85
82
86
92

63
39
43
41
48
46

125
54
54
51
46
53

250
70
71
70
72
72

500
74
73
71
73
81

1K
80
79
75
81
88

2K
81
80
77
82
88

4K
78
78
77
79
83

8K
74
73
71
74
79

m3/hr
18
45
91
182
221

dBA SPL
81
81
81
85
97

63
37
40
36
42
44

125
54
51
52
51
59

250
52
63
67
65
75

500
65
68
73
73
85

1K
70
69
74
77
91

2K
79
78
77
81
93

4K
74
74
75
78
88

8K
70
68
68
74
83

Imp. Dia.
10 in

m3/hr
21
42
64
85
102

dBA SPL
80
80
82
83
85

63
39
19
34
37
35

125
53
53
52
51
48

250
57
57
58
55
63

500
72
73
73
73
73

1K
74
71
73
76
78

2K
76
77
79
79
81

4K
72
72
74
74
77

8K
66
64
65
69
73

RPM
1500

Imp. Dia.
13 in

m3/hr
12
43
62
125
168

dBA SPL
83
81
83
85
78

63
43
46
42
44
45

125
64
56
61
61
66

250
66
58
64
64
66

500
73
70
70
73
63

1K
78
76
80
81
73

2K
80
78
79
81
75

4K
75
72
74
76
69

8K
65
59
63
65
61

RPM
1500

Imp. Dia.
12 in

m3/hr
10
25
51
102
123

dBA SPL
68
69
72
69
68

63
48
47
46
49
48

125
46
37
44
46
44

250
48
54
60
59
53

500
57
63
66
65
62

1K
62
63
66
59
62

2K
64
64
66
62
62

4K
57
61
63
61
58

8K
52
56
53
54
52

RPM
3000

Imp. Dia.
12 in

RPM
3000

Imp. Dia.
11 in

RPM
3000

101

60 Hz SOUND PRESSURE LEVELS

Pump size: 4x3V-13

9/19/2000

Flow
gpm
80
200
400
800
1000

Total
Unfiltered
dBA SPL
81
81
82
87
98

63
52
51
52
52
52

125
54
54
52
54
63

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
63
60
73
78
74
62
53
71
78
74
63
69
63
79
77
69
72
78
84
79
79
85
92
95
89

RPM
3600

Imp. Dia.
10 in

RPM
3600

Imp. Dia.
9 in

gpm
70
174
348
696
870

dBA SPL
78
81
86
90
85

63
42
40
40
41
39

125
55
56
59
60
59

250
65
67
66
71
73

500
60
63
73
78
69

1K
73
75
82
86
79

2K
75
78
82
86
82

4K
70
72
76
82
79

8K
51
56
67
73
67

RPM
1800

Imp. Dia.
13 in

gpm
108
216
324
431
517

dBA SPL
87
85
86
88
86

63
47
44
43
49
49

125
60
62
64
63
60

250
75
63
63
64
65

500
77
69
71
76
75

1K
82
81
81
83
81

2K
83
82
82
84
82

4K
79
77
76
79
77

8K
72
68
67
69
67

RPM
1800

Imp. Dia.
12 in

gpm
55
140
275
550
660

dBA SPL
69
73
77
73
73

63
47
48
47
45
47

125
39
36
39
50
55

250
47
57
59
59
61

500
57
63
70
66
64

1K
56
69
72
68
66

2K
66
69
71
68
68

4K
63
66
69
66
67

8K
54
55
56
55
60

102

8K
70
70
70
76
83

50 Hz SOUND PRESSURE LEVELS

Pump size: 6x4V-13

11/7/2000

Flow
3
m /hr
28
71
142
284
318

Total
Unfiltered
dBA SPL
87
85
80
79
86

63
42
40
42
42
42

125
52
53
48
50
53

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
71
77
82
83
78
69
75
80
82
76
61
65
72
77
73
61
66
73
76
71
67
73
81
82
78

8K
72
70
66
67
75

RPM
1500

Imp. Dia.
13 in

RPM
1500

Imp. Dia.
12 in

m /hr
28
70
141
282
284

dBA SPL
74
76
73
71
72

63
40
39
42
38
40

125
46
51
48
49
50

250
53
58
55
56
55

500
54
57
59
59
61

1K
66
69
65
58
65

2K
71
73
70
68
68

4K
67
67
65
65
65

8K
61
61
58
60
61

RPM
1500

Imp. Dia.
11 in

m /hr
18
45
91
182
227

dBA SPL
66
69
71
70
68

63
41
41
40
42
40

125
50
51
52
49
50

250
53
56
63
47
42

500
51
58
63
60
52

1K
58
62
63
63
62

2K
60
65
67
67
65

4K
60
60
63
62
60

8K
58
53
56
57
55

RPM
1000

Imp. Dia.
13 in

m /hr
17
42
85
170
213

dBA SPL
75
75
68
67
67

63
44
44
45
42
41

125
52
52
51
47
46

250
54
52
49
50
49

500
60
59
55
55
56

1K
69
68
61
61
61

2K
72
72
64
63
63

4K
66
66
60
59
59

8K
61
61
57
57
59

RPM
1000

Imp. Dia.
12 in

m /hr
14
35
70
141
169

dBA SPL
68
68
67
65
65

63
39
41
39
42
40

125
47
46
47
45
45

250
49
49
47
44
33

500
59
57
60
56
56

1K
62
64
62
60
61

2K
62
61
59
58
57

4K
60
59
58
55
56

8K
60
58
60
57
57

103

60 Hz SOUND PRESSURE LEVELS

Pump size: 6x4V-13

11/7/2000

Flow
gpm
130
325
650
1300
1600

Total
Unfiltered
dBA SPL
93
91
86
82
92

63
42
49
47
46
47

125
63
59
55
55
56

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
81
88
89
83
75
81
86
88
81
65
71
79
84
77
61
73
76
79
73
76
81
86
88
82

RPM
1800

Imp. Dia.
13 in

RPM
1800

Imp. Dia.
12 in

gpm
125
312
625
1250
1350

dBA SPL
82
82
80
78
78

63
40
40
44
43
44

125
56
47
52
58
58

250
58
62
59
60
60

500
68
71
67
64
65

1K
74
75
73
71
70

2K
79
79
77
75
74

4K
74
73
72
70
70

8K
67
66
65
65
68

RPM
1800

Imp. Dia.
11 in

gpm
110
275
550
1100
1355

dBA SPL
73
76
77
76
75

63
39
42
42
37
42

125
33
34
43
54
53

250
56
62
63
62
63

500
58
52
67
64
62

1K
67
70
72
70
70

2K
69
73
72
71
71

4K
67
69
69
68
68

8K
60
62
62
62
64

RPM
1200

Imp. Dia.
13 in

gpm
90
225
450
900
1100

dBA SPL
81
80
73
69
76

63
42
43
43
42
41

125
51
51
47
50
49

250
61
60
54
50
59

500
69
67
62
60
63

1K
76
75
67
63
70

2K
78
77
70
64
73

4K
71
71
65
61
68

8K
65
64
59
59
65

RPM
1200

Imp. Dia.
12 in

gpm
90
225
450
900
1100

dBA SPL
69
71
71
71
67

63
41
45
40
42
41

125
46
51
48
48
45

250
48
53
42
54
41

500
57
62
62
66
59

1K
65
67
67
66
63

2K
64
66
66
65
60

4K
59
60
59
59
56

8K
54
52
49
53
51

104

8K
78
76
70
66
77

Mark 3 Recessed Impeller


Durco Recessed Impeller pumps

105

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x2R-6

2/10/1999

Flow
3
m /hr
0
23
46
67

Total
Unfiltered
dBA SPL
73
74
80
77

63
41
42
42
39

125
49
50
50
48

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
56
61
62
66
70
58
62
65
68
70
59
68
71
74
76
57
63
68
72
74

8K
66
66
70
66

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5 in

3
m /hr
0
18
36
55

dBA SPL
76
77
77
78

63
42
42
42
42

125
51
50
51
49

250
59
59
58
59

500
63
64
67
67

1K
73
73
73
74

2K
70
70
71
71

4K
68
70
71
73

8K
62
63
63
64

RPM
3000

Imp. Dia.
4.5 in

3
m /hr
0
23
46

dBA SPL
73
74
76

63
43
43
42

125
51
50
49

250
57
56
58

500
65
61
65

1K
65
64
70

2K
66
67
70

4K
69
71
72

8K
61
61
61

RPM
1500

Imp. Dia.
6 in

3
m /hr
0
23
40

dBA SPL
67
69
69

63
41
41
41

125
50
51
50

250
56
55
54

500
58
57
57

1K
60
62
61

2K
62
62
62

4K
61
65
65

8K
56
56
58

RPM
1500

Imp. Dia.
5 in

3
m /hr
0
14
27

dBA SPL
65
67
67

63
43
44
44

125
48
50
50

250
57
58
56

500
54
55
55

1K
56
59
59

2K
59
59
59

4K
61
63
63

8K
52
52
53

106

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x2R-6

2/10/1999

Flow
gpm
0
100
200
293

Total
Unfiltered
dBA SPL
77
78
84
81

63
45
46
46
43

125
53
54
54
52

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
65
66
70
74
62
66
69
72
74
63
72
75
78
80
61
67
72
76
78

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5 in

gpm
0
80
160
240

dBA SPL
80
81
81
82

63
46
46
46
46

125
55
54
55
53

250
63
63
62
63

500
67
68
71
71

1K
77
77
77
78

2K
74
74
75
75

4K
72
74
75
77

8K
66
67
67
68

RPM
3600

Imp. Dia.
4.5 in

gpm
0
100
200

dBA SPL
77
78
80

63
47
47
46

125
55
54
53

250
61
60
62

500
65
65
69

1K
69
68
74

2K
70
71
74

4K
73
75
76

8K
65
65
65

RPM
1800

Imp. Dia.
6 in

gpm
0
100
175

dBA SPL
69
71
71

63
43
43
43

125
52
53
52

250
58
57
56

500
60
59
59

1K
62
64
63

2K
64
64
64

4K
63
67
67

8K
58
58
60

RPM
1800

Imp. Dia.
5 in

gpm
0
60
120

dBA SPL
67
69
69

63
45
46
46

125
49
52
52

250
59
60
58

500
56
57
57

1K
58
61
61

2K
61
61
61

4K
63
65
65

8K
54
54
55

107

8K
70
70
74
70

50 Hz SOUND PRESSURE LEVELS

Pump size: 2x2R-10

2/10/1999
RPM
3000

Imp. Dia.
10 in

Flow
3
m /hr
0
34
46
64

Total
Unfiltered
dBA SPL
79
81
83
84

63
46
41
43
42

125
48
49
50
50

108

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
65
75
74
72
67
67
75
76
76
73
67
76
79
76
74
71
77
77
78
79

8K
62
66
66
71

60 Hz SOUND PRESSURE LEVELS

Pump size: 2x2R-10

2/10/1999
RPM
3500

Imp. Dia.
10 in

Flow
gpm
0
150
200
280

Total
Unfiltered
dBA SPL
83
85
87
88

63
50
45
47
46

125
52
53
54
54

109

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
79
78
76
71
71
79
80
80
77
71
80
83
80
78
75
81
81
82
83

8K
66
70
70
75

50 Hz SOUND PRESSURE LEVELS

Pump size: 3x3R-10

2/10/1999
RPM
1500

Imp. Dia.
10 in

Flow
3
m /hr
0
57
114
171

Total
Unfiltered
dBA SPL
73
79
80
82

63
40
45
40
40

125
51
53
51
55

110

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
57
61
66
71
64
59
68
72
77
71
59
67
74
77
73
61
67
74
79
77

8K
55
60
68
67

60 Hz SOUND PRESSURE LEVELS

Pump size: 3x3R-10

2/10/1999
RPM
1800

Imp. Dia.
10 in

Flow
gpm
0
250
500
750

Total
Unfiltered
dBA SPL
75
81
82
84

63
42
47
42
42

125
53
55
53
57

111

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
59
63
68
73
66
61
70
74
79
73
61
69
76
79
75
63
69
76
81
79

8K
57
62
70
69

112

113

PolyChem S
Durco nonmetallic lined sealed horizontal pumps
-ANSI
-ISO

114

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 1.5x1-6

2/1/2001

Flow
3
m /hr
17
35
52
70
87

Total
Unfiltered
dBA SPL
71
72
69
71
70

63
35
35
35
35
35

125
43
31
43
44
53

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
61
67
59
62
66
60
63
60
69
65
60
61
62
65
60
61
63
60
63
67
64
68
58
60
56

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5.5 in

m /hr
15
30
45
60
75

dBA SPL
68
70
67
66
67

63
35
35
35
35
35

125
41
36
42
39
42

250
57
55
54
57
55

500
62
58
62
60
62

1K
56
56
59
58
47

2K
55
46
51
60
57

4K
60
69
59
59
57

8K
63
58
62
54
64

RPM
3000

Imp. Dia.
5 in

m /hr
15
30
45
60
75

dBA SPL
70
70
70
67
68

63
35
35
35
35
35

125
39
26
40
38
42

250
58
56
56
56
57

500
55
62
51
54
48

1K
60
61
55
58
58

2K
49
60
51
50
51

4K
67
66
67
65
59

8K
63
64
65
59
67

RPM
1500

Imp. Dia.
4 in

m /hr
10
20
30
40
50

dBA SPL
66
67
72
66
69

63
35
35
35
35
35

125
39
42
35
43
41

250
51
46
50
49
39

500
60
60
60
60
61

1K
59
54
51
46
54

2K
51
52
53
53
54

4K
59
60
65
59
63

8K
60
63
70
63
66

RPM
1500

Imp. Dia.
6 in

m /hr
9
17
26
35
43

dBA SPL
67
67
63
69
63

63
35
35
35
35
35

125
50
51
39
40
38

250
54
53
40
45
49

500
56
56
48
50
44

1K
60
60
53
55
53

2K
58
59
57
58
58

4K
56
55
57
57
57

8K
64
64
59
68
58

RPM
1500

Imp. Dia.
5.5 in

m /hr
7
15
23
30
38

dBA SPL
60
61
63
63
60

63
35
35
35
35
35

125
36
31
38
32
27

250
49
50
48
47
50

500
43
46
44
50
50

1K
56
56
54
56
56

2K
47
49
45
48
50

4K
50
54
52
51
40

8K
56
56
62
61
55

115

8K
56
58
57
59
52

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: PS 1.5x1-6


2/1/2001
Flow
gpm
30
60
90
120
150

Total
Unfiltered
dBA SPL
76
76
77
75
80

63
48
48
48
48
48

125
56
56
56
56
57

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
64
65
68
69
73
62
68
67
68
73
63
66
68
68
75
64
67
69
65
69
76
70
73
72
72

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5.5 in

gpm
22
45
68
90
112

dBA SPL
72
67
69
70
71

63
48
47
47
47
46

125
51
42
49
51
50

250
61
56
59
60
59

500
67
44
62
64
64

1K
60
60
60
62
63

2K
64
62
62
59
61

4K
62
62
65
63
66

8K
65
51
54
59
60

RPM
3600

Imp. Dia.
5 in

gpm
16
33
49
65
81

dBA SPL
69
72
70
70
70

63
35
50
50
49
50

125
51
47
45
50
43

250
60
60
60
60
63

500
58
65
65
62
63

1K
62
63
62
60
61

2K
59
60
62
62
59

4K
61
65
59
64
64

8K
63
66
61
58
55

RPM
3600

Imp. Dia.
4 in

gpm
12
25
38
50
62

dBA SPL
69
69
69
70
69

63
35
47
47
47
49

125
51
47
49
54
49

250
56
57
57
60
60

500
64
65
65
66
66

1K
61
63
59
62
59

2K
50
62
57
54
57

4K
64
56
63
62
62

8K
57
50
57
57
59

RPM
1800

Imp. Dia.
6 in

gpm
10
20
30
40
50

dBA SPL
70
69
62
65
65

63
35
35
35
35
35

125
32
38
32
40
51

250
57
57
55
56
57

500
58
58
54
56
58

1K
52
54
42
59
59

2K
52
52
51
53
51

4K
57
53
55
55
58

8K
69
68
58
61
55

RPM
1800

Imp. Dia.
5.5 in

gpm
9
18
27
36
45

dBA SPL
58
64
66
66
63

63
35
35
35
35
35

125
35
41
37
38
38

250
52
52
52
52
53

500
51
52
51
54
54

1K
49
49
52
49
47

2K
49
48
50
50
50

4K
53
47
55
49
46

8K
44
63
65
66
61

RPM
1800

Imp. Dia.
5 in

gpm
9
18
27
36
45

dBA SPL
64
64
65
63
62

63
35
35
35
35
35

125
40
34
37
35
41

250
47
50
48
48
48

500
45
52
51
51
51

1K
38
54
55
45
55

2K
50
53
53
53
50

4K
45
56
57
51
58

8K
64
61
62
62
57

116

8K
61
61
63
58
69

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 1.5x1-8

Flow
m3/hr
5
10
15
20
24

Total
Unfiltered
dBA SPL
73
73
73
72
74

63
35
35
35
39
35

125
42
49
51
51
53

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
56
57
61
66
60
60
68
68
58
62
66
64
60
61
65
67
62
62
65
64

RPM
3000

Imp. Dia.
8 in

RPM
3000

Imp. Dia.
7 in

m3/hr
5
10
15
20
25

dBA SPL
71
71
71
73
70

63
35
36
35
35
37

125
47
40
46
39
40

250
61
62
60
65
62

500
65
65
64
67
63

1K
65
62
65
65
63

RPM
3000

Imp. Dia.
6 in

m3/hr
5
10
15
20
25

dBA SPL
67
70
67
61
71

63
35
35
34
38
41

125
45
46
44
43
47

250
50
51
52
49
51

500
55
55
59
51
53

1K
57
64
62
52
59

117

4K
70
64
70
63
72

8K
63
66
62
61
54

2K
64
65
63
61
60

4K
64
63
64
67
62

8K
60
59
62
62
61

2K
62
66
59
49
64

4K
62
62
61
58
69

8K
60
55
59
54
64

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: PS 1.5x1-8

Flow
gpm
29
58
86
115
144

Total
Unfiltered
dBA SPL
75
76
77
77
81

63
56
58
56
58
58

125
55
56
57
60
62

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
61
69
71
67
68
62
70
72
66
68
63
71
73
68
66
64
72
73
69
65
64
71
76
77
72

8K
51
64
67
55
65

RPM
3600

Imp. Dia.
8 in

RPM
3600

Imp. Dia.
7 in

gpm
27
55
82
110
137

dBA SPL
72
72
74
73
75

63
50
53
52
52
50

125
55
46
51
54
56

250
60
61
61
60
60

500
36
62
62
61
57

1K
65
64
63
64
68

2K
66
68
70
67
69

4K
68
63
70
69
71

8K
62
58
62
65
60

RPM
3600

Imp. Dia.
6 in

gpm
24
47
71
95
119

dBA SPL
67
71
70
66
71

63
51
36
53
52
50

125
60
55
60
59
54

250
59
62
58
58
51

500
60
61
61
58
54

1K
61
64
62
60
63

2K
54
62
62
57
66

4K
60
65
62
53
65

8K
54
61
61
56
62

RPM
1800

Imp. Dia.
8 in

gpm
15
30
45
60
75

dBA SPL
66
67
65
65
65

63
35
35
35
35
35

125
31
41
42
42
44

250
42
45
46
45
49

500
47
58
50
53
54

1K
57
57
58
51
57

2K
57
64
60
50
54

4K
64
59
54
59
57

8K
60
61
60
63
62

RPM
1800

Imp. Dia.
7 in

gpm
14
28
42
56
70

dBA SPL
65
64
64
61
63

63
35
35
35
35
35

125
33
39
41
39
33

250
37
48
44
42
42

500
52
52
50
51
47

1K
57
58
54
55
49

2K
60
56
51
53
53

4K
62
57
63
56
59

8K
44
59
55
52
58

118

50 Hz SOUND PRESSURE LEVELS

Pump size: PS 2x1-10

12/6/2000

Flow
m3/hr
9
18
27
36
45

Total
Unfiltered
dBA SPL
81
80
80
82
82

63
35
35
35
35
35

125
49
45
49
53
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
57
69
79
74
58
74
77
74
56
75
76
74
65
73
79
75
63
74
79
76

RPM
3000

Imp. Dia.
10.5 in

RPM
3000

Imp. Dia.
9 in

m3/hr
6
12
18
24
30

dBA SPL
78
79
78
77
79

63
35
35
35
35
35

125
48
52
51
53
53

250
59
59
58
56
56

500
70
72
71
68
69

1K
75
77
75
74
75

RPM
3000

Imp. Dia.
8 in

m3/hr
5
11
16
21
27

dBA SPL
78
78
78
77
78

63
35
33
38
36
35

125
53
54
55
54
55

250
55
59
60
55
60

500
69
69
69
67
71

RPM
3000

Imp. Dia.
7 in

m3/hr
3
5
8
10
13

dBA SPL
77
79
77
78
76

63
40
35
35
35
35

125
50
54
52
52
49

250
59
59
57
49
49

RPM
3000

Imp. Dia.
6.5 in

m3/hr
5
10
15
20
25

dBA SPL
78
78
77
79
79

63
35
35
35
35
35

125
49
50
51
51
51

250
48
59
48
62
59

119

4K
65
66
67
68
70

8K
57
55
55
62
68

2K
73
72
72
72
74

4K
58
67
65
66
68

8K
56
54
44
56
59

1K
75
75
75
74
75

2K
72
74
73
72
73

4K
66
62
64
65
56

8K
55
53
47
52
56

500
68
71
54
63
63

1K
74
75
74
75
73

2K
72
74
73
74
73

4K
56
67
65
64
58

8K
55
58
57
58
54

500
68
65
63
67
69

1K
76
75
75
77
77

2K
71
72
72
72
72

4K
67
66
68
66
65

8K
55
56
56
57
55

60 Hz SOUND PRESSURE LEVELS

Pump size: PS 2x1-10

12/6/2000
Flow
gpm
47
95
143
190
227

Total
Unfiltered
dBA SPL
84
84
84
84
88

63
40
42
43
40
40

125
54
44
53
54
57

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
65
75
81
78
76
56
74
81
79
76
63
75
80
80
76
64
75
80
78
76
69
79
85
81
77

RPM
3600

Imp. Dia.
10.5 in

RPM
3600

Imp. Dia.
9 in

gpm
32
65
98
130
163

dBA SPL
82
84
81
82
84

63
49
50
50
48
47

125
50
52
50
44
54

250
64
63
62
64
66

500
70
74
70
69
72

1K
79
81
77
77
79

2K
77
78
77
77
79

4K
74
74
74
75
77

8K
63
47
47
63
61

RPM
3600

Imp. Dia.
8 in

gpm
30
65
95
130
160

dBA SPL
83
83
84
83
84

63
51
51
51
51
52

125
52
52
50
53
54

250
61
60
58
64
60

500
72
71
73
71
71

1K
80
78
81
79
81

2K
78
78
78
78
79

4K
75
75
76
75
76

8K
65
65
66
65
66

RPM
3600

Imp. Dia.
7 in

gpm
25
50
75
100
125

dBA SPL
83
83
83
83
84

63
35
35
45
35
35

125
51
52
53
51
54

250
67
67
68
67
67

500
72
73
72
74
72

1K
79
80
79
80
81

2K
77
76
77
76
78

4K
75
74
75
73
75

8K
66
67
66
66
66

RPM
3600

Imp. Dia.
6.5 in

gpm
26
52
78
105
131

dBA SPL
81
83
84
83
80

63
45
48
49
49
48

125
47
52
45
41
50

250
64
64
65
64
64

500
69
71
71
72
66

1K
77
79
80
80
76

2K
77
78
78
77
76

4K
74
75
76
74
73

8K
65
65
65
65
65

120

8K
63
61
58
60
67

60 Hz SOUND PRESSURE LEVELS

Pump size: PS 2x1-10

12/6/2000

Flow
gpm
25
50
75
100
125

Total
Unfiltered
dBA SPL
68
69
67
69
71

63
35
35
35
35
35

125
45
42
44
34
46

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
52
61
66
61
49
62
67
62
52
58
64
61
51
61
66
63
53
62
68
64

RPM
1800

Imp. Dia.
10.5 in

RPM
1800

Imp. Dia.
9 in

gpm
18
37
55
75
93

dBA SPL
67
68
67
68
67

63
35
35
35
35
35

125
45
47
40
46
45

250
55
54
50
53
56

500
60
60
59
60
60

1K
64
65
63
65
64

RPM
1800

Imp. Dia.
8 in

gpm
17
35
52
70
87

dBA SPL
68
67
67
67
67

63
35
35
35
35
35

125
48
46
47
47
48

250
55
55
54
56
56

500
60
58
59
59
59

RPM
1800

Imp. Dia.
7 in

gpm
12
25
38
50
62

dBA SPL
66
67
68
68
68

63
35
35
35
35
35

125
46
44
48
46
48

250
54
50
54
53
54

500
57
57
60
59
58

121

4K
53
51
55
56
58

8K
48
48
39
42
49

2K
60
61
62
62
60

4K
55
54
56
56
55

8K
49
50
47
51
47

1K
65
64
65
64
64

2K
61
59
60
60
60

4K
54
50
54
52
56

8K
47
44
42
48
48

1K
64
64
66
66
66

2K
59
61
60
59
60

4K
53
58
54
46
52

8K
47
52
49
46
48

Durco
50Hz SOUND PRESSURE LEVELS

Pump size: PS 3x2-10


12/15/00
Flow
gpm
20
40
60
80
100

Total
Unfiltered
dBA SPL
84
85
85
85
87

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
49
60
73
79
80
48
60
72
79
81
47
60
70
79
81
47
60
71
79
81
45
60
72
80
84

RPM
3000

Imp. Dia.
10 in

RPM
3000

Imp. Dia.
9 in

gpm
15
30
46
61
76

dBA SPL
78
79
79
80
80

63
39
41
41
41
42

125
53
53
45
47
59

250
61
61
61
64
70

500
70
70
71
73
73

RPM
3000

Imp. Dia.
8 in

gpm
14
29
44
58
73

dBA SPL
69
73
76
76
77

63
39
38
36
36
37

125
43
42
41
42
49

250
55
51
65
68
67

RPM
3000

Imp. Dia.
6.5 in

gpm
11
22
33
44
55

dBA SPL
76
77
73
78
79

63
39
39
39
26
35

125
51
44
48
49
52

250
64
64
60
62
61

122

2K
77
78
80
80
82

4K
71
71
73
74
76

8K
62
64
64
65
69

1K
72
74
74
74
75

2K
71
74
75
75
75

4K
65
71
51
68
66

8K
72
71
55
65
65

500
66
65
66
69
69

1K
62
65
73
72
73

2K
62
66
68
67
71

4K
58
58
66
64
57

8K
52
69
65
62
63

500
73
72
61
71
69

1K
70
74
68
77
79

2K
65
67
70
66
66

4K
60
57
63
63
62

8K
57
60
56
58
58

Durco
50Hz SOUND PRESSURE LEVELS

Pump size: PS 3x2-10


12/15/00

Flow
gpm
10
20
31
41
52

Total
Unfiltered
dBA SPL
74
74
74
73
73

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
40
50
58
63
71
40
50
57
63
71
42
51
57
63
70
39
49
56
63
69
42
49
56
63
70

2K
68
70
69
67
68

4K
65
65
66
65
65

8K
57
54
58
55
54

RPM
1500

Imp. Dia.
10 in

RPM
1500

Imp. Dia.
9 in

gpm
9
17
25
34
42

dBA SPL
69
70
71
68
68

63
39
38
33
38
40

125
42
31
40
40
43

250
53
51
50
50
51

500
52
52
53
51
45

1K
51
59
55
49
49

2K
61
60
57
58
54

4K
57
56
56
56
55

8K
67
69
71
67
68

RPM
1500

Imp. Dia.
8 in

gpm
8
16
24
32
40

dBA SPL
72
72
66
66
66

63
39
37
40
36
40

125
41
43
45
39
41

250
39
45
48
45
44

500
44
46
49
44
45

1K
47
48
56
48
42

2K
52
49
51
51
52

4K
58
58
57
47
57

8K
72
71
64
65
65

RPM
1500

Imp. Dia.
6.5 in

gpm
7
14
21
28
37

dBA SPL
69
68
69
69
72

63
35
34
35
37
37

125
45
40
40
46
42

250
49
48
49
47
50

500
56
44
56
61
66

1K
61
58
61
61
62

2K
67
68
66
67
69

4K
58
54
61
58
64

8K
53
46
40
40
53

123

124

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 4x3-10

12/6/2000

Flow
m3/hr
17
34
51
68
85

Total
Unfiltered
dBA SPL
71
70
72
72
72

63
35
35
35
35
35

125
40
43
43
39
42

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
54
56
46
62
55
52
59
59
48
52
64
66
36
53
60
65
48
51
52
61

RPM
1500

Imp. Dia.
10.5 in

RPM
1500

Imp. Dia.
10 in

m3/hr
18
36
54
72
90

dBA SPL
70
71
72
72
72

63
35
35
35
35
35

125
36
44
40
40
36

250
49
54
51
56
53

500
53
53
57
45
48

1K
52
53
62
64
60

RPM
1500

Imp. Dia.
9 in

m3/hr
15
30
45
60
75

dBA SPL
71
69
71
72
71

63
35
35
35
35
35

125
29
38
40
46
37

250
48
48
47
46
44

500
53
52
55
55
51

RPM
1500

Imp. Dia.
7 in

m3/hr
10
20
30
40
50

dBA SPL
68
70
69
71
69

63
35
35
35
35
35

125
41
39
38
39
37

250
38
46
36
44
34

500
46
49
45
50
47

125

4K
64
64
65
65
65

8K
69
68
68
70
70

2K
55
49
66
64
64

4K
63
63
64
65
64

8K
69
70
69
69
70

1K
56
58
62
56
55

2K
60
54
63
64
55

4K
62
63
64
63
63

8K
70
67
68
70
70

1K
51
55
56
55
55

2K
51
51
51
48
52

4K
62
62
62
61
62

8K
66
69
68
70
67

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: PS 4x3-10

########
Flow
gpm
100
200
300
400
500

Total
Unfiltered
dBA SPL
76
76
79
76
76

63
35
35
35
35
35

125
47
41
35
43
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
71
63
62
64
68
72
62
60
68
69
74
67
70
73
68
72
66
65
69
68
72
62
62
64
67

RPM
1800

Imp. Dia.
10.5 in

RPM
1800

Imp. Dia.
10 in

gpm
94
187
281
375
469

dBA SPL
75
77
75
76
73

63
35
35
35
35
35

125
46
40
43
41
42

250
64
66
66
65
63

500
61
59
60
58
58

1K
66
69
69
68
65

2K
65
72
68
64
60

4K
66
67
66
66
66

8K
72
73
70
74
69

RPM
1800

Imp. Dia.
9 in

gpm
81
162
244
325
406

dBA SPL
73
73
73
73
73

63
35
35
35
35
35

125
50
47
44
48
46

250
51
42
52
50
55

500
57
55
59
55
58

1K
64
64
65
66
64

2K
60
56
64
64
62

4K
64
64
65
65
65

8K
71
72
70
70
71

RPM
1800

Imp. Dia.
7 in

gpm
50
100
150
200
250

dBA SPL
73
72
71
73
73

63
35
35
35
35
35

125
36
43
44
45
46

250
47
38
46
49
52

500
54
48
54
54
55

1K
61
61
61
63
62

2K
57
52
60
61
47

4K
64
64
64
65
64

8K
72
70
69
72
71

126

8K
72
69
70
68
71

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 4x3-13

5/1/2001
Flow
m3/hr

RPM
1500

Imp. Dia.
13.25 in

RPM
1500

Imp. Dia.
12 in

m3/hr

RPM
1500

Imp. Dia.
11 in.

m3/hr

28
56
84
112
140

25
51
76
102
127

24
48
72
96
120

Total
Unfiltered
dBA SPL
73
77
79
82
78

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
64
68
67
67
57
72
68
70
72
61
75
69
71
73
65
79
73
73
72
66
72
71
72
71
63

63
41
39
38
27
37

125
61
56
53
51
51

dBA SPL
69
71
72
72
71

63
0
0
0
0
0

125
53
51
46
44
41

250
60
58
59
55
59

500
58
57
59
54
60

1K
63
67
68
67
65

2K
62
66
69
68
66

4K
58
62
62
62
62

8K
63
60
59
65
63

dBA SPL
66
70
72
70
66

63
0
0
0
0
0

125
52
48
42
43
49

250
53
53
51
54
53

500
52
54
64
54
54

1K
62
64
68
64
56

2K
54
67
68
67
59

4K
48
51
56
57
49

8K
60
61
61
61
64

127

8K
64
63
64
60
52

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: PS 4x3-13

5/1/2001
Flow
gpm
163
325
488
650
813

Total
Unfiltered
dBA SPL
79
78
78
80
81

63
36
33
37
18
48

125
57
46
51
53
52

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
64
74
72
73
63
64
69
72
75
64
68
67
71
75
59
72
71
74
77
56
70
72
74
79
66

RPM
1800

Imp. Dia.
13.25 in

RPM
1800

Imp. Dia.
12 in

gpm
137
275
412
550
687

dBA SPL
70
76
78
82
80

63
0
0
0
0
0

125
60
58
46
50
56

250
57
60
72
79
71

500
52
60
65
70
71

1K
63
71
71
75
73

2K
65
73
73
76
74

4K
63
62
66
70
70

8K
62
61
62
61
71

RPM
1800

Imp. Dia.
11 in.

gpm
113
226
339
552
665

dBA SPL
69
78
76
76
71

63
0
0
0
0
0

125
56
50
48
50
56

250
57
73
63
69
60

500
61
65
62
65
48

1K
61
72
72
68
65

2K
61
73
72
71
67

4K
65
67
67
65
62

8K
59
61
48
62
63

RPM
1800

Imp. Dia.
9 in

gpm
125
250
375
500
625

dBA SPL
67
72
70
64
69

63
0
0
0
0
0

125
52
48
42
47
54

250
57
57
52
51
61

500
56
58
50
55
61

1K
55
64
63
57
62

2K
61
66
65
60
60

4K
59
54
62
45
59

8K
63
68
66
59
60

RPM
1200

Imp. Dia.
13.25 in

gpm
107
213
319
426
533

dBA SPL
71
66
72
66
67

63
0
0
0
0
0

125
37
43
36
39
37

250
56
53
52
52
56

500
60
56
67
55
61

1K
62
59
67
59
59

2K
59
60
67
61
60

4K
55
56
54
55
61

8K
69
59
57
61
57

RPM
1200

Imp. Dia.
12 in

gpm
100
200
300
400
500

dBA SPL
67
69
70
65
65

63
0
0
0
0
0

125
52
46
48
33
50

250
54
48
52
50
57

500
59
53
51
50
54

1K
59
63
64
59
52

2K
57
61
68
62
56

4K
55
53
55
55
54

8K
64
65
57
52
62

RPM
1200

Imp. Dia.
11 in.

gpm
87
174
261
348
435

dBA SPL
63
67
63
64
59

63
0
0
0
0
0

125
45
43
43
45
45

250
51
48
48
50
52

500
51
51
42
50
48

1K
55
62
58
55
52

2K
54
59
60
60
51

4K
52
58
50
55
51

8K
61
61
54
56
50

128

8K
67
62
64
62
62

129

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 50x32-160

7/26/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
5
72
10
73
15
72
20
72
25
77

RPM
3000

Imp. Dia.
170 mm

RPM
3000

Imp. Dia.
160 mm

m /hr

RPM
3000

Imp. Dia.
140 mm

m /hr

RPM
1500

Imp. Dia.
160 mm

m /hr

4
8
12
16
20

3
6
9
12
15

3
5
8
10
13

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
56
58
64
67
68
59
63
68
70
51
62
64
66
65
65
61
65
64
62
66
61
68
73
73
62

63
0
0
0
0
0

125
49
48
50
50
52

dBA SPL
66
74
73
70
68

63
0
0
0
0
0

125
42
38
41
33
41

250
50
42
34
47
50

500
56
57
56
53
55

1K
60
68
68
62
59

2K
63
69
69
61
58

4K
56
70
66
68
65

8K
56
63
52
56
60

dBA SPL
68
67
63
67
67

63
0
0
0
0
0

125
35
39
39
40
37

250
46
47
47
48
47

500
44
51
46
52
49

1K
56
56
60
54
56

2K
57
62
52
59
38

4K
65
63
58
66
65

8K
61
57
54
58
62

dBA SPL
60
59
60
60
59

63
0
0
0
0
0

125
46
44
41
43
35

250
48
47
45
44
45

500
47
48
48
50
47

1K
54
52
52
52
52

2K
51
46
55
39
51

4K
42
54
50
56
53

8K
56
53
55
53
55

130

8K
60
58
61
63
60

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 80x65-160

8/10/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
13
75
26
72
39
70
52
71
65
72

RPM
3000

Imp. Dia.
170 mm

RPM
3000

Imp. Dia.
160 mm

m /hr

RPM
3000

Imp. Dia.
140 mm

m /hr

RPM
1500

Imp. Dia.
170 mm

m /hr

13
25
37
50
62

10
20
30
40
50

7
13
19
26
33

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
53
62
69
68
71
53
59
64
64
70
49
57
63
65
67
60
62
66
66
65
57
65
66
65
63

63
42
43
41
41
42

125
44
39
30
46
47

dBA SPL
71
70
69
74
67

63
37
36
41
35
37

125
37
37
44
40
42

250
50
49
48
42
53

500
59
57
56
60
61

1K
66
64
64
65
57

2K
69
62
62
68
59

4K
53
67
65
71
56

8K
58
60
55
64
62

dBA SPL
65
65
62
67
65

63
37
28
35
26
35

125
33
39
37
39
42

250
45
46
43
45
42

500
51
52
51
53
53

1K
58
58
54
56
60

2K
59
50
49
63
58

4K
62
61
59
60
60

8K
54
58
55
58
58

dBA SPL
60
63
63
64
63

63
37
30
36
36
37

125
37
40
42
41
10

250
43
45
35
42
40

500
48
43
50
43
45

1K
49
43
31
54
53

2K
47
48
52
53
52

4K
58
59
58
59
59

8K
53
60
60
60
59

131

8K
57
59
59
57
62

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 65x40-200

8/10/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
11
76
23
77
33
81
45
82
57
66

RPM
3000

Imp. Dia.
210 mm

RPM
3000

Imp. Dia.
180 mm

m /hr

RPM
3000

Imp. Dia.
160 mm

m /hr

RPM
1500

Imp. Dia.
210 mm

m /hr

10
20
30
40
50

9
17
26
34
43

6
12
18
24
30

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
66
70
69
72
61
67
70
72
73
69
70
76
76
73
67
70
76
77
75
42
53
60
58
60

63
36
0
0
0
35

125
47
48
59
57
31

dBA SPL
76
71
72
70
71

63
38
36
35
36
34

125
43
40
39
44
44

250
54
51
50
52
53

500
59
57
60
59
59

1K
71
66
67
66
65

2K
73
67
67
67
67

4K
60
53
66
55
57

8K
64
64
57
53
62

dBA SPL
72
70
70
67
71

63
36
33
37
36
34

125
46
45
48
45
43

250
53
53
52
52
56

500
59
58
56
59
60

1K
67
63
65
61
63

2K
66
65
64
64
69

4K
67
64
65
34
61

8K
59
60
58
59
59

dBA SPL
64
65
65
65
63

63
27
26
34
0
34

125
40
44
44
43
43

250
56
57
57
55
44

500
57
59
59
58
46

1K
55
58
58
55
45

2K
45
53
53
53
55

4K
57
58
58
55
58

8K
60
56
59
62
59

132

8K
59
62
66
72
59

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 50x32-250


########
Flow
m3/hr

RPM
3000

Imp. Dia.
266 mm

RPM
3000

Imp. Dia.
220 mm

m3/hr

RPM
3000

Imp. Dia.
190 mm

m3/hr

RPM
3000

Imp. Dia.
160 mm

m3/hr

RPM
1500

Imp. Dia.
266 mm

m3/hr

RPM
1500

Imp. Dia.
220 mm

m3/hr

9
17
25
34
42

7
13
20
27
34

6
11
17
22
28

4
9
13
17
22

5
9
14
19
24

4
9
14
18
22

Total
Unfiltered
dBA SPL
74
77
78
80
79

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
63
68
67
65
69
71
69
72
70
68
67
69
73
67
73
63
71
76
74
72
53
72
76
72
67

63
35
35
35
35
35

125
47
45
44
41
48

dBA SPL
75
74
75
71
74

63
35
35
35
35
35

125
50
49
48
47
52

250
58
53
55
51
56

500
65
63
64
63
66

1K
60
60
62
62
63

2K
68
66
62
65
65

4K
72
72
74
67
72

8K
59
63
60
60
57

dBA SPL
75
74
73
77
74

63
35
35
35
35
35

125
52
47
46
49
49

250
60
58
57
57
58

500
69
68
63
67
68

1K
66
64
63
64
66

2K
62
60
62
63
65

4K
72
72
71
75
70

8K
61
60
63
64
63

dBA SPL
71
74
76
75
72

63
35
35
35
35
35

125
46
44
40
42
43

250
54
54
53
53
53

500
61
66
63
61
67

1K
59
61
58
51
60

2K
55
63
56
59
60

4K
69
73
76
74
70

8K
60
60
67
62
61

dBA SPL
64
68
66
67
62

63
35
35
35
35
35

125
41
35
46
45
46

250
49
49
47
51
50

500
50
58
51
49
49

1K
57
62
57
55
57

2K
59
62
51
58
43

4K
53
59
55
54
51

8K
60
60
65
65
59

dBA SPL
61
62
62
64
62

63
35
35
35
35
35

125
45
43
46
39
46

250
56
57
51
57
57

500
43
55
53
50
51

1K
53
53
52
50
54

2K
51
53
52
43
49

4K
54
53
49
58
48

8K
54
55
60
60
56

133

8K
54
62
61
64
60

134

135

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: PS 100x65-250

12/20/2000

Total
Flow Unfiltered
3
m /hr dBA SPL
4
67
8
69
11
71
15
69
19
68

RPM
1500

Imp. Dia.
266 mm

RPM
1500

Imp. Dia.
220 mm

m /hr

RPM
1500

Imp. Dia.
190 mm

m /hr

RPM
1500

Imp. Dia.
160 mm

m /hr

3
6
9
12
15

2
4
6
8
11

2
3
5
6
7

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
58
59
57
60
62
58
64
62
54
61
61
64
62
57
59
51
63
62
52
58
55
61
59
59

63
35
35
35
35
35

125
44
45
41
42
42

dBA SPL
62
67
67
66
67

63
35
35
35
35
35

125
40
42
38
42
29

250
53
54
53
54
54

500
58
55
59
49
58

1K
52
61
61
61
59

2K
48
63
63
59
61

4K
55
48
51
60
57

8K
56
58
59
57
62

dBA SPL
62
63
64
64
64

63
35
35
35
35
35

125
22
28
36
39
41

250
46
39
48
48
50

500
54
50
54
54
56

1K
43
53
57
55
56

2K
53
47
41
51
50

4K
57
57
57
60
60

8K
58
60
61
60
57

dBA SPL
67
65
64
64
64

63
35
35
35
35
35

125
44
46
44
45
43

250
52
51
50
51
52

500
55
52
52
53
53

1K
57
55
55
58
58

2K
54
54
54
55
54

4K
57
57
56
59
57

8K
66
63
61
54
58

136

8K
60
61
66
65
63

Durco

50 Hz SOUND PRESSURE LEVELS

Pump size: PS 100x65-315

5/1/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
26
71
52
74
78
73
104
72
130
72

RPM
1500

Imp. Dia.
330 mm

RPM
1500

Imp. Dia.
290 mm

m /hr

RPM
1500

Imp. Dia.
270 mm

m /hr

RPM
1500

Imp. Dia.
230 mm

m /hr

20
40
60
80
100

18
36
54
72
90

17
34
51
68
85

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
57
62
65
65
58
58
63
70
70
63
61
62
69
69
56
57
61
68
68
52
59
63
67
67
57

63
0
0
0
0
0

125
51
47
46
44
47

dBA SPL
72
71
73
71
67

63
0
0
0
0
0

125
43
34
37
43
37

250
54
56
56
52
52

500
59
59
62
59
61

1K
66
66
68
66
60

2K
67
69
69
66
63

4K
61
51
52
58
55

8K
65
60
64
63
58

dBA SPL
69
73
72
69
68

63
0
0
0
0
0

125
41
42
23
36
37

250
53
57
50
50
51

500
57
61
59
58
58

1K
60
68
64
59
56

2K
63
68
64
65
58

4K
47
57
61
60
43

8K
67
67
68
63
66

dBA SPL
69
72
71
68
70

63
0
0
0
0
0

125
35
38
41
39
33

250
48
50
51
51
51

500
50
53
54
54
53

1K
46
48
55
46
44

2K
33
53
52
52
52

4K
60
62
63
61
61

8K
68
71
70
67
69

137

8K
63
52
61
64
64

Durco

50 Hz SOUND PRESSURE LEVELS

Pump size: PS 125x100-315

5/1/2001
Flow
m3/hr

RPM
1500

Imp. Dia.
330 mm

RPM
1500

Imp. Dia.
290 mm

m3/hr

RPM
1500

Imp. Dia.
270 mm

m3/hr

RPM
1500

Imp. Dia.
230 mm

m3/hr

RPM
1000

Imp. Dia.
330 mm

m3/hr

51
102
153
204
255

42
85
128
170
212

40
80
120
160
200

36
62
98
124
160

28
57
85
114
142

Total
Unfiltered
dBA SPL
78
81
78
81
78

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
70
72
72
69
77
73
72
75
70
65
73
72
72
69
64
65
71
80
68
65
70
73
74
67

63
0
0
0
0
0

125
60
58
48
58
51

dBA SPL
75
73
72
72
72

63
0
0
0
0
0

125
48
49
44
49
48

250
60
57
58
58
58

500
65
65
65
65
65

1K
69
68
66
65
65

2K
70
67
67
67
65

4K
63
65
62
63
64

8K
66
65
61
51
65

dBA SPL
68
72
69
68
71

63
0
0
0
0
0

125
48
45
37
37
45

250
54
53
52
53
58

500
60
61
64
63
65

1K
59
63
61
59
62

2K
62
67
64
60
61

4K
63
62
62
61
62

8K
60
67
58
61
65

dBA SPL
67
71
64
67
66

63
0
0
0
0
0

125
42
46
45
46
46

250
54
54
51
55
55

500
56
57
52
57
58

1K
54
65
55
56
46

2K
60
66
57
52
56

4K
62
65
59
60
61

8K
62
61
53
63
62

dBA SPL
68
67
66
61
65

63
0
0
0
0
0

125
34
39
42
38
40

250
51
50
50
50
50

500
57
57
56
55
56

1K
58
63
58
54
55

2K
56
57
63
51
51

4K
54
57
43
50
52

8K
66
60
54
55
63

138

8K
62
62
56
59
65

PolyChem M
Durco nonmetallic lined sealless horizontal pumps
-ANSI
-ISO

139

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 1.5x1-6

4/23/2001
Flow
m3/hr

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5.5 in

m3/hr

RPM
3000

Imp. Dia.
5 in

m3/hr

RPM
3000

Imp. Dia.
4 in

m3/hr

5
10
15
20
25

5
9
14
18
23

4
8
12
16
20

4
7
11
14
16

Total
Unfiltered
dBA SPL
73
76
74
75
72

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
49
64
67
67
69
57
66
71
72
66
58
67
68
70
65
37
66
69
71
68
56
65
67
67
63

63
0
0
0
0
0

125
45
38
43
41
41

dBA SPL
71
74
73
74
72

63
0
0
0
0
0

125
42
47
46
45
46

250
57
55
50
52
57

500
63
66
62
66
62

1K
63
69
65
68
65

2K
65
69
67
70
66

4K
68
68
69
68
68

8K
40
44
47
59
54

dBA SPL
72
72
72
72
71

63
0
0
0
0
0

125
47
47
48
46
45

250
59
57
58
59
57

500
61
65
64
66
60

1K
65
67
66
67
66

2K
67
67
68
66
65

4K
65
64
65
61
66

8K
55
46
53
53
55

dBA SPL
73
73
73
72
75

63
0
0
0
0
0

125
49
47
50
48
50

250
53
55
49
48
55

500
63
60
59
61
65

1K
67
66
67
66
69

2K
68
68
68
66
71

4K
65
68
68
68
66

8K
60
52
54
57
61

140

8K
51
51
57
63
56

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 1.5x1-6

4/23/2001
Flow
gpm
25
50
75
100
125

Total
Unfiltered
dBA SPL
77
80
78
83
80

63
40
39
33
28
40

125
52
56
52
56
52

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
62
70
73
71
69
65
71
74
76
73
63
67
74
74
71
68
74
78
78
77
65
71
75
75
72

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5.5 in

gpm
24
48
72
96
115

dBA SPL
81
80
78
79
77

63
49
47
49
50
51

125
52
52
53
54
53

250
65
66
65
65
66

500
74
74
73
72
72

1K
74
73
71
72
73

2K
77
75
71
73
69

4K
73
70
70
71
67

8K
56
58
59
59
55

RPM
3600

Imp. Dia.
5 in

gpm
21
43
64
86
96

dBA SPL
78
77
74
77
76

63
45
47
43
46
45

125
52
51
49
52
52

250
65
63
62
64
64

500
72
72
71
72
71

1K
72
71
63
71
68

2K
72
71
68
72
71

4K
70
70
61
67
69

8K
57
54
54
56
57

RPM
3600

Imp. Dia.
4 in

gpm
20
40
60
80

dBA SPL
78
76
78
78

63
51
51
50
50

125
50
48
50
52

250
65
66
68
69

500
70
69
72
71

1K
71
71
70
70

2K
73
67
72
73

4K
71
65
69
70

8K
59
59
59
58

RPM
1800

Imp. Dia.
6 in

gpm
13
26
39
52
65

dBA SPL
65
64
65
62
64

63
0
0
0
0
0

125
42
42
42
43
43

250
52
52
48
45
50

500
61
60
60
59
61

1K
56
56
59
56
57

2K
47
56
52
47
40

4K
59
59
56
54
58

8K
55
52
60
54
37

141

8K
62
66
63
68
63

Durco
50Hz SOUND PRESSURE LEVELS

Pump size: P_ 3x2-6


04/24/01
Flow
gpm
37
75
113
150
187

Total
Unfiltered
dBA SPL
67
70
69
70
71

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
0
48
57
55
54
0
41
59
60
60
0
42
52
62
56
0
43
57
60
61
0
40
58
68
59

2K
60
64
64
66
64

4K
63
64
62
65
63

8K
61
61
63
60
61

RPM
3000

Imp. Dia.
6 in

RPM
3000

Imp. Dia.
5.5 in

gpm
28
56
84
112
140

dBA SPL
67
68
68
69
69

63
0
0
0
0
0

125
36
38
39
40
39

250
49
53
54
54
53

500
61
63
49
63
64

1K
57
58
56
54
60

2K
58
59
59
59
59

4K
60
58
57
61
63

8K
62
64
66
66
61

RPM
3000

Imp. Dia.
4.5 in

gpm
23
57
81
94
117

dBA SPL
67
69
67
68
63

63
0
0
0
0
0

125
38
43
42
41
40

250
43
43
42
45
52

500
61
57
62
63
47

1K
48
52
53
46
55

2K
55
56
55
55
57

4K
60
68
59
61
59

8K
64
55
62
65
56

142

Durco
60Hz SOUND PRESSURE LEVELS

Pump size: P_ 3x2-6


04/24/01
Flow
gpm
44
87
131
175
219

Total
Unfiltered
dBA SPL
74
69
75
77
78

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
48
48
57
66
66
47
50
54
63
61
46
48
57
58
66
48
49
56
66
68
50
37
69
71
73

RPM
3600

Imp. Dia.
6 in

RPM
3600

Imp. Dia.
5.5 in

gpm
32
65
98
130
162

dBA SPL
76
75
76
75
73

63
33
34
37
38
36

125
49
46
50
49
52

250
60
61
61
61
61

500
69
67
67
67
67

RPM
3600

Imp. Dia.
4.5 in

gpm
30
60
90
120
150

dBA SPL
78
72
71
69
68

63
46
45
45
46
49

125
47
51
53
51
49

250
63
60
59
59
57

RPM
1800

Imp. Dia.
6 in

gpm
25
50
75
100
125

dBA SPL
63
60
60
63
58

63
0
0
0
0
0

125
37
31
27
39
36

250
46
48
48
56
52

143

2K
69
65
67
71
71

4K
69
61
73
74
66

8K
57
59
55
59
59

1K
70
71
71
68
68

2K
71
71
72
69
68

4K
65
66
68
71
58

8K
52
50
55
56
60

500
71
65
65
57
55

1K
75
64
65
65
63

2K
72
64
61
61
60

4K
63
68
65
65
64

8K
57
60
55
47
57

500
44
48
50
47
50

1K
49
54
46
52
49

2K
49
52
55
51
52

4K
55
51
54
54
48

8K
62
56
52
60
51

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 1.5x1-8

12/7/2000

Flow
m3/hr
5
10
15
20
25

Total
Unfiltered
dBA SPL
72
72
71
69
73

63
35
45
35
35
38

125
41
43
45
43
34

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
48
53
57
68
49
50
62
67
51
56
58
63
46
55
61
64
45
58
65
69

RPM
3000

Imp. Dia.
8 in

RPM
3000

Imp. Dia.
7 in

m3/hr
5
9
14
19
24

dBA SPL
70
70
66
67
64

63
37
28
35
36
30

125
46
46
42
45
45

250
46
46
47
50
49

500
55
51
52
59
40

1K
63
55
53
53
55

RPM
3000

Imp. Dia.
6.5 in

m3/hr
5
9
13
18
23

dBA SPL
66
66
67
67
67

63
35
35
35
35
35

125
48
50
49
50
47

250
54
45
56
55
56

500
61
57
59
59
60

RPM
1500

Imp. Dia.
8 in

m3/hr
3
5
8
10
13

dBA SPL
63
63
62
63
67

63
35
35
35
35
35

125
41
42
40
18
35

250
42
45
44
43
34

RPM
1500

Imp. Dia.
7 in

m3/hr
3
5
8
10
13

dBA SPL
62
62
62
61
65

63
35
35
35
35
35

125
38
35
39
28
30

250
34
31
36
38
38

144

4K
70
68
69
63
68

8K
61
63
65
60
60

2K
67
60
63
64
62

4K
61
69
61
57
59

8K
42
59
59
58
50

1K
59
60
60
60
60

2K
60
60
60
60
58

4K
57
60
57
60
60

8K
56
57
58
58
60

500
51
49
48
39
49

1K
54
54
54
49
57

2K
56
52
53
49
58

4K
55
59
55
51
58

8K
60
57
58
62
65

500
39
45
41
46
47

1K
49
51
51
45
52

2K
52
54
54
53
52

4K
55
57
60
58
56

8K
60
57
55
55
64

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 1.5x1-8

12/7/2000
Flow
gpm
27
55
83
110
137

Total
Unfiltered
dBA SPL
76
77
69
72
78

63
39
32
35
41
46

125
50
46
46
45
46

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
49
61
61
70
75
49
59
67
74
72
49
59
59
66
54
52
49
64
67
67
54
65
68
73
75

RPM
3600

Imp. Dia.
8 in

RPM
3600

Imp. Dia.
7 in

gpm
27
55
83
110
126

dBA SPL
71
71
76
72
79

63
50
52
51
51
49

125
46
50
47
48
41

250
49
45
51
50
47

500
52
60
62
63
62

1K
59
61
55
61
65

2K
62
62
61
68
71

4K
69
65
75
64
78

8K
63
66
63
66
67

RPM
3600

Imp. Dia.
6 in

gpm
24
47
71
95
118

dBA SPL
70
70
69
69
71

63
39
41
40
44
44

125
51
47
52
46
54

250
60
64
61
62
61

500
62
67
60
65
59

1K
66
63
60
60
62

2K
59
58
60
63
64

4K
63
57
64
61
65

8K
62
59
60
50
64

RPM
1800

Imp. Dia.
8 in

gpm
15
30
45
60
75

dBA SPL
65
68
62
65
64

63
35
35
35
35
35

125
35
42
39
41
44

250
43
45
44
46
41

500
47
61
44
48
50

1K
51
60
52
40
54

2K
53
62
57
53
56

4K
59
61
59
42
59

8K
62
60
48
64
59

RPM
1800

Imp. Dia.
7 in

gpm
15
30
45
60
72

dBA SPL
64
63
61
63
65

63
35
35
35
35
35

125
42
41
41
42
42

250
44
45
42
42
43

500
47
46
39
45
54

1K
56
55
55
55
57

2K
52
51
52
49
56

4K
57
58
55
48
52

8K
62
59
58
62
63

145

8K
60
64
63
64
62

50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 2x1-10

12/6/2000

Flow
m3/hr
12
24
36
48
60

Total
Unfiltered
dBA SPL
73
74
75
76
84

63
0
0
0
0
0

125
34
49
51
46
40

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
52
65
69
66
53
61
71
69
61
65
71
69
57
70
72
67
67
78
82
75

RPM
3000

Imp. Dia.
10.5 in

RPM
3000

Imp. Dia.
9 in

m3/hr
9
18
27
36
45

dBA SPL
69
69
71
73
75

63
0
0
0
0
0

125
32
33
37
38
40

250
49
48
46
45
47

500
58
63
63
66
66

1K
62
57
61
69
69

RPM
3000

Imp. Dia.
8 in

m3/hr
7
14
20
27
34

dBA SPL
70
68
70
70
69

63
0
0
0
0
0

125
42
38
37
38
35

250
55
55
57
57
59

500
60
61
60
59
61

RPM
3000

Imp. Dia.
7 in

m3/hr
6
12
17
23
28

dBA SPL
70
70
68
69
73

63
0
0
0
0
0

125
36
40
43
44
44

250
47
44
49
43
49

500
58
59
59
56
62

Flow
m3/hr
5
10
15
20
25

Total
Unfiltered
dBA SPL
64
67
60
61
62

12/6/2000
RPM
1500

Imp. Dia.
10.5 in

63
0
0
0
0
0

125
39
37
37
37
28

4K
67
65
68
61
61

8K
57
61
63
62
64

2K
58
63
65
69
70

4K
66
65
67
53
65

8K
58
58
64
60
67

1K
63
62
63
63
61

2K
64
64
66
64
63

4K
65
60
61
63
62

8K
45
44
59
63
62

1K
62
65
60
60
68

2K
67
61
61
60
69

4K
60
66
65
67
65

8K
62
60
60
59
58

4K
60
56
49
40
56

8K
60
59
54
56
54

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
37
55
51
52
45
61
50
63
36
55
55
44
37
52
56
54
42
56
50
57

146

60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 2x1-10

12/6/2000
Flow
gpm
53
105
158
210
257

Total
Unfiltered
dBA SPL
76
80
78
80
84

63
0
0
36
0
0

125
49
55
58
52
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
70
71
68
70
60
66
76
74
73
62
69
74
74
63
58
70
78
73
64
70
74
81
80
74

RPM
3600

Imp. Dia.
10.5 in

RPM
3600

Imp. Dia.
9 in

gpm
45
90
135
180
225

dBA SPL
77
78
77
78
79

63
0
0
0
0
0

125
51
51
51
52
51

250
64
66
65
66
66

500
66
67
66
66
68

1K
70
73
72
73
72

2K
70
75
74
74
75

4K
74
70
68
70
67

8K
59
54
62
51
70

RPM
3600

Imp. Dia.
8 in

gpm
37
75
112
150
175

dBA SPL
73
76
75
75
76

63
0
0
0
0
0

125
42
41
47
34
40

250
53
53
56
56
59

500
72
73
70
68
60

1K
50
65
69
69
71

2K
60
65
71
70
71

4K
60
70
64
69
69

8K
61
61
56
60
69

RPM
3600

Imp. Dia.
7 in

gpm
30
60
90
120
150

dBA SPL
72
73
71
73
75

63
50
51
51
51
50

125
54
54
54
52
53

250
60
59
60
60
60

500
61
61
59
58
64

1K
66
65
63
64
66

2K
59
66
65
64
67

4K
68
69
68
71
73

8K
60
61
60
61
63

147

8K
59
60
65
66
67

60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 2x1-10

12/6/2000
RPM
1800

Imp. Dia.
10.5 in

RPM
1800

Imp. Dia.
9 in

Flow
gpm
26
52
78
105
131

Total
Unfiltered
dBA SPL
68
68
66
66
69

63
0
0
0
0
0

125
35
40
42
35
35

gpm
21
42
64
85
107

dBA SPL
63
68
64
61
65

63
0
0
0
0
0

125
39
37
25
38
33

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
44
58
65
53
48
58
62
65
45
56
49
62
45
56
60
55
48
63
58
60

250
41
39
43
47
49

148

500
39
61
51
47
51

1K
54
60
57
51
49

2K
37
65
53
52
58

4K
60
59
60
60
63

8K
62
54
61
61
61

4K
59
55
58
58
56

8K
59
59
60
55
63

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 3x2-10


06/27/01
Flow
gpm
24
48
72
96
120

Total
Unfiltered
dBA SPL
77
78
78
76
79

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
0
52
60
54
65
0
46
54
64
74
0
47
55
66
71
0
42
56
56
72
0
39
65
66
73

RPM
3000

Imp. Dia.
10.5 in

2K
74
74
75
73
75

4K
73
69
70
67
70

8K
55
57
60
60
65

RPM
3000

Imp. Dia.
9 in

gpm
23
43
69
91
114

dBA SPL
79
78
77
75
83

63
0
0
0
0
0

125
44
44
40
46
38

250
53
50
58
60
74

500
61
66
58
60
76

1K
76
72
70
69
78

2K
75
74
75
72
77

4K
64
73
66
68
74

8K
62
62
68
51
61

RPM
3000

Imp. Dia.
8 in

gpm
18
36
54
72
90

dBA SPL
72
75
76
77
76

63
0
0
0
0
0

125
52
49
44
46
47

250
44
55
56
63
62

500
63
57
59
64
62

1K
63
69
70
69
73

2K
66
73
73
72
70

4K
67
57
68
72
70

8K
60
66
59
62
55

RPM
3000

Imp. Dia.
6.5 in

gpm
14
28
42
56
70

dBA SPL
72
73
74
72
73

63
0
0
0
0
0

125
48
49
44
46
48

250
56
57
61
64
59

500
61
60
65
55
65

1K
62
62
67
67
68

2K
66
67
69
65
68

4K
68
69
67
63
61

8K
61
66
52
60
66

RPM
1500

Imp. Dia.
10.5 in

gpm
11
22
33
44
55

dBA SPL
69
65
66
69
67

63
0
0
0
0
0

125
42
44
41
42
36

250
53
37
46
47
43

500
61
45
51
56
40

1K
58
57
49
63
62

2K
57
59
59
65
62

4K
60
59
58
58
57

8K
66
60
63
59
61

RPM
1500

Imp. Dia.
9 in

gpm
10
19
29
38
48

dBA SPL
66
67
65
64
64

63
0
0
0
0
0

125
44
42
42
41
40

250
49
47
46
47
46

500
59
47
52
50
44

1K
55
55
56
59
60

2K
60
47
56
60
51

4K
59
59
59
59
53

8K
58
65
61
42
61

149

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 3x2-10

06/27/01
Flow
gpm
125
250
375
500
600

Total
Unfiltered
dBA SPL
84
84
85
86
86

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
51
48
70
81
77
52
58
63
83
76
53
56
66
83
79
53
60
60
84
79
52
54
65
84
78

RPM
3600

Imp. Dia.
10.5 in

RPM
3600

Imp. Dia.
9 in

gpm
115
230
345
460
575

dBA SPL
76
79
80
80
81

63
45
48
46
45
45

125
52
49
47
55
56

250
63
60
60
64
65

500
67
65
71
72
73

RPM
3600

Imp. Dia.
8 in

gpm
100
200
300
400
500

dBA SPL
78
77
76
77
79

63
42
45
43
43
44

125
49
50
50
49
43

250
62
64
63
64
68

RPM
3600

Imp. Dia.
6.5 in

gpm
78
156
234
313
391

dBA SPL
70
76
76
76
79

63
47
48
48
50
48

125
48
49
49
45
50

250
61
62
63
64
65

150

2K
74
77
79
79
78

4K
72
66
67
70
66

8K
65
59
63
64
66

1K
71
74
75
75
77

2K
71
76
76
75
76

4K
64
66
70
68
71

8K
63
60
63
62
65

500
63
56
68
65
65

1K
75
69
69
72
76

2K
73
75
72
74
74

4K
68
70
70
67
63

8K
51
56
55
55
57

500
61
66
69
69
70

1K
64
69
69
70
76

2K
64
73
72
70
71

4K
65
68
63
69
72

8K
57
60
61
53
55

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 3x2-10


06/27/01

Flow
gpm
63
125
188
250
312

Total
Unfiltered
dBA SPL
71
65
69
74
68

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
63
125
250
500
1K
0
38
55
54
61
0
41
56
51
51
0
36
54
53
60
0
43
57
61
69
0
40
57
56
64

2K
57
59
65
70
64

4K
54
59
61
64
41

8K
71
57
62
61
59

RPM
1800

Imp. Dia.
10.5 in

RPM
1800

Imp. Dia.
9 in

gpm
55
110
165
220
275

dBA SPL
72
70
70
70
72

63
0
0
0
0
0

125
43
41
42
40
41

250
50
48
54
52
47

500
50
55
54
61
54

1K
57
60
63
57
65

2K
64
63
65
64
64

4K
54
60
63
63
55

8K
71
67
63
65
70

RPM
1800

Imp. Dia.
8 in

gpm
47
95
142
190
237

dBA SPL
70
64
69
69
69

63
0
0
0
0
0

125
49
49
49
49
49

250
50
50
50
51
50

500
64
53
56
54
45

1K
57
59
63
63
62

2K
65
59
65
65
65

4K
52
53
58
54
51

8K
66
56
63
65
63

151

Durco
60 Hz SOUND PRESSURE LEVELS

Pump size: P_ 4x3-10

6/27/2001
Flow
gpm
100
200
300
400
500

Total
Unfiltered
dBA SPL
73
78
79
78
72

63
0
0
0
0
0

125
42
44
44
48
34

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
65
67
67
64
63
68
70
71
73
69
69
70
74
73
67
67
68
74
73
61
65
65
66
66
58

RPM
1800

Imp. Dia.
10.5 in

RPM
1800

Imp. Dia.
9 in

gpm
87
175
262
350
437

dBA SPL
64
66
72
70
65

63
0
0
0
0
0

125
42
32
43
48
48

250
49
41
51
53
40

500
53
55
61
60
61

1K
56
59
68
65
51

2K
59
59
68
66
57

4K
56
60
59
59
55

8K
60
61
61
54
59

RPM
1800

Imp. Dia.
8 in

gpm
75
150
225
300
375

dBA SPL
65
64
64
64
66

63
41
36
35
40
34

125
44
43
39
36
41

250
51
51
51
51
51

500
53
55
47
54
49

1K
61
60
57
58
62

2K
57
55
52
53
58

4K
57
56
59
57
57

8K
57
57
58
58
59

152

8K
61
58
65
63
60

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 4x3-10

6/27/2001
RPM
1500

Imp. Dia.
10.5 in

RPM
1500

Imp. Dia.
9 in

Flow
m3/hr
18
36
54
72
90

m3/hr
15
31
46
62
77

Total
Unfiltered
dBA SPL
65
67
71
70
71

63
0
0
0
0
0

125
32
39
44
44
42

dBA SPL
61
62
68
68
66

63
0
0
0
0
0

125
39
39
32
43
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
49
51
53
58
58
49
55
54
61
63
53
58
65
68
55
57
58
65
66
58
61
58
66
65
58

153

250
45
44
45
45
51

500
54
51
57
50
48

1K
52
56
63
64
56

2K
47
56
64
62
62

4K
50
52
50
56
53

8K
61
58
63
56
64

8K
58
55
54
63
61

50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 50x32-160


3/8/1999
Flow
m3/hr
2
9
14
19
22

Total
Unfiltered
dBA SPL
66
74
71
70
69

63
0
0
0
0
0

125
36
43
41
40
42

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
48
45
61
62
59
47
57
66
72
67
46
56
62
69
64
46
54
64
68
61
48
55
63
65
61

8K
58
58
56
56
59

RPM
2900

Imp. Dia.
170 mm

RPM
2900

Imp. Dia.
160 mm

m3/hr
2
8
12
16
19

dBA SPL
67
73
74
71
68

63
0
0
0
0
0

125
45
41
42
43
40

250
47
46
47
45
47

500
57
60
61
61
59

1K
63
64
66
60
51

2K
64
71
72
69
67

4K
53
65
66
62
58

8K
52
54
55
54
51

RPM
2900

Imp. Dia.
140 mm

m3/hr
1
7
10
14
16

dBA SPL
64
71
73
68
67

63
0
0
0
0
0

125
29
31
40
38
37

250
43
45
49
48
48

500
52
58
63
58
55

1K
62
61
64
56
56

2K
57
69
70
66
65

4K
49
64
65
61
60

8K
52
55
55
53
54

RPM
1450

Imp. Dia.
170 mm

m3/hr
1
5
8
10
12

dBA SPL
64
63
64
65
65

63
0
0
0
0
0

125
36
27
37
35
36

250
46
45
45
41
39

500
59
59
59
60
60

1K
49
48
48
46
46

2K
61
59
61
62
62

4K
52
52
52
53
53

8K
44
44
44
38
31

RPM
1450

Imp. Dia.
160 mm

m3/hr
1
4
6
8
10

dBA SPL
65
65
65
66
65

63
0
0
0
0
0

125
31
44
36
35
36

250
38
38
38
43
38

500
59
60
61
62
61

1K
53
51
51
55
53

2K
64
63
62
63
62

4K
52
52
52
54
52

8K
44
44
39
42
42

RPM
1450

Imp. Dia.
140 mm

m3/hr
1
3
5
6
8

dBA SPL
66
64
64
62
62

63
0
0
0
0
0

125
34
36
35
36
37

250
46
46
46
46
47

500
61
60
61
61
59

1K
61
57
58
54
57

2K
62
58
57
52
54

4K
56
53
52
49
48

8K
38
34
44
39
44

154

155

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 65x40-200

7/9/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
11
84
22
84
33
83
45
84
56
84

RPM
3000

Imp. Dia.
210 mm

RPM
3000

Imp. Dia.
180 mm

m /hr

RPM
1500

Imp. Dia.
210 mm

m /hr

RPM
1500

Imp. Dia.
180 mm

m /hr

10
20
30
40
50

6
11
16
23
29

5
10
15
20
25

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
75
78
80
74
67
75
78
80
74
67
75
77
80
73
68
75
78
80
73
67
75
78
80
74

63
0
0
0
0
0

125
54
53
52
54
54

dBA SPL
68
64
63
61
63

63
0
0
0
0
0

125
41
39
43
44
44

250
56
54
56
54
54

500
56
58
52
55
59

1K
61
56
57
53
56

2K
63
57
53
55
50

4K
61
58
59
51
56

8K
60
53
52
47
47

dBA SPL
78
79
79
78
78

63
0
0
0
0
0

125
45
44
46
44
42

250
64
64
64
64
64

500
70
70
70
71
70

1K
72
73
73
73
72

2K
75
75
75
74
74

4K
70
70
70
69
71

8K
54
55
57
57
58

dBA SPL
66
67
66
65
65

63
0
0
0
0
0

125
54
48
56
55
54

250
50
61
55
55
60

500
55
57
60
62
61

1K
64
61
62
54
55

2K
51
55
54
49
53

4K
54
61
58
57
41

8K
48
47
44
52
49

156

8K
58
55
55
56
57

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 50x32-250

12/6/2000

Total
Flow Unfiltered
3
m /hr dBA SPL
11
71
21
71
32
72
42
71
53
71

RPM
3000

Imp. Dia.
260 mm

RPM
3000

Imp. Dia.
250 mm

m /hr

RPM
3000

Imp. Dia.
190 mm

m /hr

RPM
3000

Imp. Dia.
160 mm

m /hr

10
19
29
38
48

7
13
20
26
33

5
10
15
20
25

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
55
57
60
61
63
55
61
63
63
64
55
63
63
63
64
55
62
63
58
64
55
60
62
60
64

63
35
35
35
35
35

125
44
45
46
44
45

dBA SPL
75
78
78
77
82

63
35
35
35
35
35

125
43
44
40
47
46

250
53
53
56
56
59

500
71
73
70
69
74

1K
64
68
70
70
77

2K
65
67
71
71
75

4K
70
75
74
72
74

8K
63
64
65
48
66

dBA SPL
75
77
77
76
79

63
35
35
35
35
35

125
56
56
56
56
56

250
65
66
66
66
64

500
69
72
70
69
71

1K
69
73
71
70
75

2K
71
70
73
71
72

4K
62
66
64
59
67

8K
52
61
62
61
59

dBA SPL
74
74
74
73
75

63
35
35
35
35
35

125
55
55
54
53
54

250
60
59
60
60
60

500
65
65
64
63
66

1K
68
67
66
67
69

2K
64
68
67
66
71

4K
70
70
70
68
69

8K
58
58
56
58
62

157

8K
68
67
69
67
67

Durco
50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 50x32-250

RPM
1500

Imp. Dia.
260 mm

m3/hr
6
11
17
22
28

dBA SPL
68
67
68
68
67

63
35
35
35
35
35

125
43
43
44
44
45

250
54
54
54
54
55

500
58
57
58
58
59

1K
58
59
60
60
60

2K
57
58
57
58
58

4K
62
62
62
63
63

8K
65
62
63
62
45

RPM
1500

Imp. Dia.
250 mm

m3/hr
5
10
15
20
25

dBA SPL
68
68
70
67
73

63
35
35
35
35
35

125
35
37
36
36
36

250
50
49
48
48
50

500
55
56
56
55
62

1K
60
61
59
58
69

2K
60
56
59
57
65

4K
59
45
54
54
57

8K
65
67
69
65
68

RPM
1500

Imp. Dia.
190 mm

m3/hr
3
6
9
12
16

dBA SPL
72
73
72
74
73

63
35
35
35
35
35

125
44
46
44
44
49

250
56
59
57
58
61

500
66
69
67
69
71

1K
67
64
68
62
62

2K
67
67
64
71
68

4K
56
62
60
64
61

8K
51
51
51
53
54

RPM
1500

Imp. Dia.
160 mm

m3/hr
3
6
9
12
16

dBA SPL
73
74
73
73
73

63
35
35
35
35
35

125
46
31
42
40
42

250
53
53
54
52
54

500
62
63
63
62
64

1K
66
68
65
64
69

2K
68
64
64
64
70

4K
69
70
70
71
60

8K
62
61
60
59
58

158

50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 80x50-250

7/24/2001

Total
Flow Unfiltered
3
m /hr dBA SPL
20
81
40
82
60
82
80
84
100
82

RPM
3000

Imp. Dia.
266 mm

RPM
3000

Imp. Dia.
250 mm

m /hr

RPM
3000

Imp. Dia.
220 mm

m /hr

RPM
3000

Imp. Dia.
160 mm

m /hr

17
34
51
68
85

16
32
48
64
80

10
20
30
40
50

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
54
79
69
74
71
58
80
73
74
71
57
80
70
72
70
57
83
62
69
72
53
80
74
69
71

63
43
42
39
14
36

125
47
50
44
50
48

dBA SPL
77
76
75
78
78

63
31
36
37
38
37

125
25
47
41
48
50

250
52
58
59
56
45

500
72
62
68
72
71

1K
69
64
67
75
75

2K
72
75
69
70
71

4K
65
61
69
66
62

8K
64
62
51
59
65

dBA SPL
73
77
78
77
77

63
37
37
39
36
39

125
52
47
46
42
46

250
58
58
60
48
56

500
60
61
71
65
65

1K
68
73
70
66
74

2K
69
73
74
74
71

4K
61
68
71
71
69

8K
65
62
67
66
64

dBA SPL
75
75
75
75
75

63
38
38
11
32
33

125
46
51
52
51
48

250
66
68
68
69
66

500
68
61
64
63
70

1K
67
70
67
70
70

2K
70
65
66
64
65

4K
67
68
68
68
67

8K
56
64
66
66
63

159

8K
61
63
56
63
59

50 Hz SOUND PRESSURE LEVELS

Pump size: P_ 80x50-250

7/24/2001
RPM
1500

Imp. Dia.
266 mm

RPM
1500

Imp. Dia.
250 mm

Flow
m3/hr
10
20
30
40
50

Total
Unfiltered
dBA SPL
69
68
70
70
70

63
45
37
43
40
40

125
28
45
45
44
44

m3/hr
17
34
51
68
85

dBA SPL
66
66
65
63
63

63
0
0
37
0
30

125
41
40
42
39
43

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
52
57
57
49
50
56
57
60
50
58
61
58
49
59
50
57
53
61
62
53

250
51
45
46
43
40

160

500
55
45
54
52
53

1K
60
60
60
59
55

2K
60
60
57
60
59

4K
68
66
67
69
67

8K
59
55
62
60
59

4K
59
62
59
55
57

8K
56
54
54
43
51

Chemstar

Durco ISO metallic sealed horizontal pump

161

50 Hz SOUND PRESSURE LEVELS

Pump size: 50x32-250

2/10/1999

Flow
3
m /hr
2.5
12
18
24
28

Total
Unfiltered
dBA SPL
77
76
75
76
85

63
37
37
39
37
40

125
52
47
45
50
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
67
76
64
63
62
66
75
65
66
56
64
73
67
59
55
65
73
70
65
53
69
77
81
81
75

8K
41
43
42
56
70

RPM
3000

Imp. Dia.
260 mm

RPM
3000

Imp. Dia.
240 mm

m /hr
2.3
11
17
22
25

dBA SPL
73
73
74
75
80

63
44
43
43
42
44

125
46
43
48
50
55

250
64
64
64
65
67

500
72
72
72
73
75

1K
58
54
65
67
74

2K
53
59
55
62
73

4K
61
58
64
61
70

8K
57
56
59
59
68

RPM
3000

Imp. Dia.
220 mm

3
m /hr
2
10
15
20
22

dBA SPL
79
80
80
80
80

63
40
39
38
37
41

125
52
49
49
47
48

250
70
69
70
70
70

500
76
75
76
76
76

1K
74
76
75
75
76

2K
70
64
70
69
70

4K
64
56
59
62
67

8K
58
45
45
59
64

RPM
1500

Imp. Dia.
260 mm

3
m /hr
6
29
43
57
68

dBA SPL
62
69
66
63
68

63
24
38
39
17
19

125
43
44
44
45
46

250
51
51
53
52
55

500
54
57
57
57
63

1K
43
65
59
36
61

2K
55
65
62
58
60

4K
59
59
58
58
61

8K
46
35
36
34
56

RPM
1500

Imp. Dia.
240 mm

3
m /hr
5
25
38
50
63

dBA SPL
62
63
63
62
66

63
24
15
15
32
24

125
43
39
43
45
46

250
54
52
52
54
55

500
55
57
57
56
59

1K
52
61
59
53
58

2K
54
51
54
53
59

4K
56
43
54
56
59

8K
46
33
32
45
53

162

60 Hz SOUND PRESSURE LEVELS

Pump size: 50x32-250

2/10/1999

Flow
3
m /hr
2.5
12
18
24
28

Total
Unfiltered
dBA SPL
81
80
79
80
89

63
41
41
43
41
44

125
56
51
49
54
62

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
71
80
68
67
66
70
79
69
70
60
68
77
71
63
59
69
77
74
69
57
73
81
85
85
79

8K
45
47
46
60
74

RPM
3600

Imp. Dia.
260 mm

RPM
3600

Imp. Dia.
240 mm

m /hr
2.3
11
17
22
25

dBA SPL
77
77
78
79
84

63
48
47
47
46
48

125
50
47
52
54
59

250
68
68
68
69
71

500
76
76
76
77
79

1K
62
58
69
71
78

2K
57
63
59
66
77

4K
65
62
68
65
74

8K
61
60
63
63
72

RPM
3600

Imp. Dia.
220 mm

3
m /hr
2
10
15
20
22

dBA SPL
83
84
84
84
84

63
44
43
42
41
45

125
56
53
53
51
52

250
74
73
74
74
74

500
80
79
80
80
80

1K
78
80
79
79
80

2K
74
68
74
73
74

4K
68
60
63
66
71

8K
62
49
49
63
68

RPM
1800

Imp. Dia.
260 mm

3
m /hr
6
29
43
57
68

dBA SPL
64
71
68
65
70

63
26
40
41
19
21

125
45
46
46
47
48

250
53
53
55
54
57

500
56
59
59
59
65

1K
45
67
61
38
63

2K
57
67
64
60
62

4K
61
61
60
60
63

8K
48
37
38
36
58

RPM
1800

Imp. Dia.
240 mm

3
m /hr
5
25
38
50
63

dBA SPL
64
65
65
64
68

63
26
17
17
34
26

125
45
41
45
47
48

250
56
54
54
56
57

500
57
59
59
58
61

1K
54
63
61
55
60

2K
56
53
56
55
61

4K
58
45
56
58
61

8K
48
35
34
47
55

163

50 Hz SOUND PRESSURE LEVELS

Pump size: 65x40-250

2/10/1999

Flow
3
m /hr
12
24
36
48
56

Total
Unfiltered
dBA SPL
81
81
82
82
86

63
45
43
43
47
46

125
57
26
44
56
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
71
72
79
69
51
71
72
80
61
60
73
73
80
72
59
73
74
80
74
67
73
81
82
79
73

8K
56
50
49
59
67

RPM
3000

Imp. Dia.
260 mm

RPM
3000

Imp. Dia.
240 mm

m /hr
10
20
30
40
50

dBA SPL
81
81
82
82
84

63
37
37
37
37
37

125
55
55
56
57
59

250
66
67
66
68
71

500
76
76
76
77
80

1K
76
76
78
77
79

2K
73
75
75
75
77

4K
69
70
70
69
71

8K
61
61
62
61
67

RPM
3000

Imp. Dia.
220 mm

3
m /hr
9
18
26
35
44

dBA SPL
81
81
82
81
82

63
42
42
41
41
42

125
55
55
55
57
59

250
65
65
65
67
69

500
74
74
74
75
76

1K
78
78
79
78
78

2K
73
74
74
74
75

4K
68
69
69
69
70

8K
61
60
61
62
64

RPM
1500

Imp. Dia.
260 mm

3
m /hr
6
12
17
23
29

dBA SPL
62
65
59
58
58

63
40
39
39
40
39

125
52
53
53
52
53

250
51
51
51
51
52

500
28
56
28
27
27

1K
60
63
51
51
36

2K
53
58
56
53
54

4K
47
46
44
42
42

8K
34
34
30
30
32

RPM
1500

Imp. Dia.
240 mm

3
m /hr
5
10
16
21
26

dBA SPL
64
66
64
65
65

63
38
37
37
37
37

125
40
37
39
38
41

250
49
51
51
51
50

500
62
63
62
63
61

1K
54
57
50
53
54

2K
56
60
54
56
59

4K
56
56
56
55
58

8K
46
47
46
46
51

164

60 Hz SOUND PRESSURE LEVELS

Pump size: 65x40-250

2/10/1999

Flow
3
m /hr
12
24
36
48
56

Total
Unfiltered
dBA SPL
85
85
86
86
90

63
49
47
47
51
50

125
61
30
48
60
62

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
75
76
83
73
55
75
76
84
65
64
77
77
84
76
63
77
78
84
78
71
77
85
86
83
77

8K
60
54
53
63
71

RPM
3600

Imp. Dia.
260 mm

RPM
3600

Imp. Dia.
240 mm

m /hr
10
20
30
40
50

dBA SPL
85
85
86
86
88

63
41
41
41
41
41

125
59
59
60
61
63

250
70
71
70
72
75

500
80
80
80
81
84

1K
80
80
82
81
83

2K
77
79
79
79
81

4K
73
74
74
73
75

8K
65
65
66
65
71

RPM
3600

Imp. Dia.
220 mm

3
m /hr
9
18
26
35
44

dBA SPL
85
85
86
85
86

63
46
46
45
45
46

125
59
59
59
61
63

250
69
69
69
71
73

500
78
78
78
79
80

1K
82
82
83
82
82

2K
77
78
78
78
79

4K
72
73
73
73
74

8K
65
64
65
66
68

RPM
1800

Imp. Dia.
260 mm

3
m /hr
6
12
17
23
29

dBA SPL
64
67
61
60
60

63
42
41
41
42
41

125
54
55
55
54
55

250
53
53
53
53
54

500
30
58
30
29
29

1K
62
65
53
53
38

2K
55
60
58
55
56

4K
49
48
46
44
44

8K
36
36
32
32
34

RPM
1800

Imp. Dia.
240 mm

3
m /hr
5
10
16
21
26

dBA SPL
66
68
66
67
67

63
40
39
39
39
39

125
42
39
41
40
43

250
51
53
53
53
52

500
64
65
64
65
63

1K
56
59
52
55
56

2K
58
62
56
58
61

4K
58
58
58
57
60

8K
48
49
48
48
53

165

50 Hz SOUND PRESSURE LEVELS

Pump size: 80x50-250

2/10/1999

Flow
3
m /hr
16
33
49
65
81

Total
Unfiltered
dBA SPL
78
77
78
77
80

63
44
42
44
44
42

125
54
42
50
49
51

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
65
77
65
62
66
56
76
60
67
60
60
75
71
69
66
62
76
72
58
64
66
78
72
70
66

8K
61
50
55
45
57

RPM
3000

Imp. Dia.
260 mm

RPM
3000

Imp. Dia.
240 mm

m /hr
15
30
45
60
75

dBA SPL
82
82
81
82
84

63
46
46
46
45
45

125
52
53
51
39
43

250
71
71
71
72
75

500
78
78
78
78
78

1K
78
77
77
78
79

2K
74
74
68
75
76

4K
61
59
61
67
70

8K
47
48
50
47
59

RPM
3000

Imp. Dia.
220 mm

m /hr
13
25
38
50
63

dBA SPL
81
76
77
79
79

63
44
44
43
45
44

125
51
35
36
33
40

250
73
70
73
76
75

500
79
72
73
73
74

1K
74
68
69
72
71

2K
70
62
60
63
60

4K
63
57
60
57
59

8K
54
44
47
47
48

RPM
1500

Imp. Dia.
260 mm

3
m /hr
9
18
26
35
44

dBA SPL
69
65
66
66
65

63
0
0
0
0
0

125
50
50
51
51
52

250
46
46
46
46
39

500
60
57
56
58
60

1K
67
63
63
63
61

2K
55
54
58
59
52

4K
54
56
57
58
57

8K
34
34
34
32
40

RPM
1500

Imp. Dia.
240 mm

3
m /hr
8
15
23
30
38

dBA SPL
64
62
63
63
63

63
0
0
0
0
0

125
48
49
49
49
50

250
55
55
57
57
57

500
35
28
28
36
37

1K
61
59
60
60
60

2K
56
51
50
50
47

4K
56
56
56
56
56

8K
34
44
44
42
44

166

60 Hz SOUND PRESSURE LEVELS

Pump size: 80x50-250

2/10/1999

Flow
3
m /hr
16
33
49
65
81

Total
Unfiltered
dBA SPL
82
81
82
81
84

63
48
46
48
48
46

125
58
46
54
53
55

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
81
69
66
70
60
80
64
71
64
64
79
75
73
70
66
80
76
62
68
70
82
76
74
70

8K
65
54
59
49
61

RPM
3600

Imp. Dia.
260 mm

RPM
3600

Imp. Dia.
240 mm

m /hr
15
30
45
60
75

dBA SPL
86
86
85
86
88

63
50
50
50
49
49

125
56
57
55
43
47

250
75
75
75
76
79

500
82
82
82
82
82

1K
82
81
81
82
83

2K
78
78
72
79
80

4K
65
63
65
71
74

8K
51
52
54
51
63

RPM
3600

Imp. Dia.
220 mm

m /hr
13
25
38
50
63

dBA SPL
85
80
81
83
83

63
48
48
47
49
48

125
55
39
40
37
44

250
77
74
77
80
79

500
83
76
77
77
78

1K
78
72
73
76
75

2K
74
66
64
67
64

4K
67
61
64
61
63

8K
58
48
51
51
52

RPM
1800

Imp. Dia.
260 mm

3
m /hr
9
18
26
35
44

dBA SPL
71
67
68
68
67

63
0
0
0
0
0

125
52
52
53
53
54

250
48
48
48
48
41

500
62
59
58
60
62

1K
69
65
65
65
63

2K
57
56
60
61
54

4K
56
58
59
60
59

8K
36
36
36
34
42

RPM
1800

Imp. Dia.
240 mm

3
m /hr
8
15
23
30
38

dBA SPL
66
64
65
65
65

63
0
0
0
0
0

125
50
51
51
51
52

250
57
57
59
59
59

500
37
30
30
38
39

1K
63
61
62
62
62

2K
58
53
52
52
49

4K
58
58
58
58
58

8K
36
46
46
44
46

167

50 Hz SOUND PRESSURE LEVELS

Pump size: 100x65-250

2/10/1999

Flow
3
m /hr
21
43
64
85
106

Total
Unfiltered
dBA SPL
85
84
83
82
83

63
38
38
39
40
39

125
59
57
58
57
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
76
79
81
77
74
76
77
79
75
70
76
77
78
73
65
75
78
77
73
68
78
77
78
73

8K
71
68
64
63
65

RPM
3000

Imp. Dia.
260 mm

RPM
3000

Imp. Dia.
240 mm

m /hr
19
38
56
75
94

dBA SPL
79
80
80
81
80

63
36
37
37
36
39

125
54
43
40
41
52

250
69
66
61
60
56

500
72
71
72
73
73

1K
74
74
76
76
76

2K
72
76
76
76
76

4K
68
72
71
72
72

8K
49
63
62
62
61

RPM
3000

Imp. Dia.
220 mm

m /hr
16
33
49
65
81

dBA SPL
77
76
77
79
78

63
41
20
33
39
40

125
30
46
53
49
52

250
35
54
43
53
46

500
64
67
67
72
72

1K
74
72
72
73
71

2K
74
72
73
75
74

4K
67
66
68
68
68

8K
58
60
60
61
61

RPM
1500

Imp. Dia.
260 mm

3
m /hr
5
23
34
45
56

dBA SPL
70
65
64
62
67

63
0
0
0
0
0

125
51
49
49
48
47

250
58
48
40
37
49

500
59
55
53
57
54

1K
58
49
55
42
63

2K
66
63
59
57
61

4K
63
59
59
57
60

8K
56
51
49
45
50

RPM
1500

Imp. Dia.
240 mm

3
m /hr
4
20
29
39
49

dBA SPL
62
65
63
60
63

63
25
0
0
0
0

125
46
43
41
39
43

250
49
46
46
46
48

500
52
53
46
48
37

1K
55
62
55
38
61

2K
48
56
58
54
28

4K
58
59
59
56
57

8K
51
50
50
50
50

168

60 Hz SOUND PRESSURE LEVELS

Pump size: 100x65-250

2/10/1999

Flow
3
m /hr
21
43
64
85
106

Total
Unfiltered
dBA SPL
89
88
87
86
87

63
42
42
43
44
43

125
63
61
62
61
62

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
81
80
83
85
81
78
80
81
83
79
74
80
81
82
77
69
79
82
81
77
72
82
81
82
77

8K
75
72
68
67
69

RPM
3600

Imp. Dia.
260 mm

RPM
3600

Imp. Dia.
240 mm

m /hr
19
38
56
75
94

dBA SPL
83
84
84
85
84

63
40
41
41
40
43

125
58
47
44
45
56

250
73
70
65
64
60

500
76
75
76
77
77

1K
78
78
80
80
80

2K
76
80
80
80
80

4K
72
76
75
76
76

8K
53
67
66
66
65

RPM
3600

Imp. Dia.
220 mm

m /hr
16
33
49
65
81

dBA SPL
81
80
81
83
82

63
45
24
37
43
44

125
34
50
57
53
56

250
39
58
47
57
50

500
68
71
71
76
76

1K
78
76
76
77
75

2K
78
76
77
79
78

4K
71
70
72
72
72

8K
62
64
64
65
65

RPM
1800

Imp. Dia.
260 mm

3
m /hr
5
23
34
45
56

dBA SPL
72
67
66
64
69

63
0
0
0
0
0

125
53
51
51
50
49

250
60
50
42
39
51

500
61
57
55
59
56

1K
60
51
57
44
65

2K
68
65
61
59
63

4K
65
61
61
59
62

8K
58
53
51
47
52

RPM
1800

Imp. Dia.
240 mm

3
m /hr
4
20
29
39
49

dBA SPL
64
67
65
62
65

63
0
0
0
0
0

125
48
45
43
41
45

250
51
48
48
48
50

500
54
55
48
50
39

1K
57
64
57
40
63

2K
50
58
60
56
30

4K
60
61
61
58
59

8K
53
52
52
52
52

169

50 Hz SOUND PRESSURE LEVELS

Pump size: 65x40-315

2/10/1999

Flow
3
m /hr
10
21
32
42
51

Total
Unfiltered
dBA SPL
82
82
80
79
87

63
39
46
38
38
42

125
53
55
49
55
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
69
73
77
74
75
66
73
77
77
72
67
73
76
74
71
69
73
74
72
71
72
79
81
83
79

8K
71
64
64
66
73

RPM
3000

Imp. Dia.
320 mm

RPM
3000

Imp. Dia.
300 mm

3
m /hr
9
19
28
38
45

dBA SPL
78
78
79
79
85

63
33
37
40
22
33

125
50
50
54
56
58

250
62
63
62
66
67

500
68
67
54
71
77

1K
71
70
71
71
80

2K
73
75
76
74
80

4K
71
72
72
71
77

8K
65
63
64
65
74

RPM
3000

Imp. Dia.
280 mm

3
m /hr
8
16
24
32
40

dBA SPL
77
78
79
80
84

63
47
47
49
49
49

125
49
54
56
62
64

250
63
65
66
72
74

500
70
69
70
73
76

1K
71
72
73
73
78

2K
71
74
74
75
77

4K
68
69
71
71
75

8K
62
62
61
62
73

RPM
1500

Imp. Dia.
320 mm

3
m /hr
5
11
17
22
27

dBA SPL
60
65
67
65
74

63
0
0
0
0
0

125
24
27
25
29
45

250
51
49
51
52
63

500
57
58
59
59
69

1K
49
63
62
60
68

2K
49
54
61
54
68

4K
53
56
59
57
63

8K
39
47
49
51
59

RPM
1500

Imp. Dia.
300 mm

3
m /hr
5
9
13
18
23

dBA SPL
62
66
67
65
67

63
0
0
0
0
0

125
18
27
29
36
24

250
53
54
54
53
53

500
47
58
59
55
56

1K
59
60
61
60
61

2K
55
61
62
60
60

4K
52
55
56
55
60

8K
48
51
53
54
58

170

60 Hz SOUND PRESSURE LEVELS

Pump size: 65x40-315

2/10/1999

Flow
3
m /hr
10
21
32
42
51

Total
Unfiltered
dBA SPL
86
86
84
83
91

63
43
50
42
42
46

125
57
59
53
59
65

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
77
81
78
79
70
77
81
81
76
71
77
80
78
75
73
77
78
76
75
76
83
85
87
83

8K
75
68
68
70
77

RPM
3600

Imp. Dia.
320 mm

RPM
3600

Imp. Dia.
300 mm

3
m /hr
9
19
28
38
45

dBA SPL
82
82
83
83
89

63
37
41
44
26
37

125
54
54
58
60
62

250
66
67
66
70
71

500
72
71
58
75
81

1K
75
74
75
75
84

2K
77
79
80
78
84

4K
75
76
76
75
81

8K
69
67
68
69
78

RPM
3600

Imp. Dia.
280 mm

3
m /hr
8
16
24
32
40

dBA SPL
81
82
83
84
88

63
51
51
53
53
53

125
53
58
60
66
68

250
67
69
70
76
78

500
74
73
74
77
80

1K
75
76
77
77
82

2K
75
78
78
79
81

4K
72
73
75
75
79

8K
66
66
65
66
77

RPM
1800

Imp. Dia.
320 mm

3
m /hr
5
11
17
22
27

dBA SPL
62
67
69
67
76

63
0
0
0
0
0

125
26
29
27
31
47

250
53
51
53
54
65

500
59
60
61
61
71

1K
51
65
64
62
70

2K
51
56
63
56
70

4K
55
58
61
59
65

8K
41
49
51
53
61

RPM
1800

Imp. Dia.
300 mm

3
m /hr
5
9
13
18
23

dBA SPL
64
68
69
67
69

63
0
0
0
0
0

125
20
29
31
38
26

250
55
56
56
55
55

500
49
60
61
57
58

1K
61
62
63
62
63

2K
57
63
64
62
62

4K
54
57
58
57
62

8K
50
53
55
56
60

171

50 Hz SOUND PRESSURE LEVELS

Pump size: 80x50-315

2/10/1999

Flow
3
m /hr
16
33
49
65
81

Total
Unfiltered
dBA SPL
84
85
85
85
87

63
39
35
33
25
38

125
60
60
61
61
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
73
77
80
78
75
74
77
81
79
73
74
77
81
79
74
73
76
80
79
75
73
78
82
81
78

8K
70
67
67
69
72

RPM
3000

Imp. Dia.
320 mm

RPM
3000

Imp. Dia.
300 mm

m /hr
15
31
47
62
78

dBA SPL
77
79
77
77
87

63
45
43
43
45
46

125
54
50
51
52
54

250
65
61
64
63
70

500
70
70
71
70
79

1K
73
73
70
60
82

2K
70
75
73
74
82

4K
68
68
68
71
77

8K
62
61
60
62
72

RPM
3000

Imp. Dia.
280 mm

m /hr
15
29
43
58
73

dBA SPL
75
76
77
77
87

63
44
43
44
44
46

125
45
42
44
48
51

250
61
60
61
63
70

500
68
69
70
68
80

1K
72
70
69
65
81

2K
68
71
73
75
82

4K
67
67
68
70
76

8K
59
59
57
59
69

RPM
1500

Imp. Dia.
320 mm

3
m /hr
8
17
25
33
41

dBA SPL
66
66
68
68
69

63
42
0
0
0
0

125
50
47
41
40
47

250
53
53
53
55
58

500
62
62
63
63
62

1K
62
62
63
64
66

2K
58
52
59
62
63

4K
54
57
58
58
58

8K
45
44
35
42
42

RPM
1500

Imp. Dia.
300 mm

3
m /hr
7
15
23
30
38

dBA SPL
61
64
64
64
65

63
0
0
0
0
0

125
25
29
25
25
44

250
53
50
50
45
52

500
53
60
58
54
57

1K
55
58
58
60
58

2K
45
54
51
54
58

4K
57
59
59
59
59

8K
45
44
49
48
52

172

60 Hz SOUND PRESSURE LEVELS

Pump size: 80x50-315

2/10/1999

Flow
3
m /hr
16
33
49
65
81

Total
Unfiltered
dBA SPL
88
89
89
89
91

63
43
39
37
29
42

125
64
64
65
65
65

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
77
81
84
82
79
78
81
85
83
77
78
81
85
83
78
77
80
84
83
79
77
82
86
85
82

8K
74
71
71
73
76

RPM
3600

Imp. Dia.
320 mm

RPM
3600

Imp. Dia.
300 mm

m /hr
15
31
47
62
78

dBA SPL
81
83
81
81
91

63
49
47
47
49
50

125
58
54
55
56
58

250
69
65
68
67
74

500
74
74
75
74
83

1K
77
77
74
64
86

2K
74
79
77
78
86

4K
72
72
72
75
81

8K
66
65
64
66
76

RPM
3600

Imp. Dia.
280 mm

m /hr
15
29
43
58
73

dBA SPL
79
80
81
81
91

63
48
47
48
48
50

125
49
46
48
52
55

250
65
64
65
67
74

500
72
73
74
72
84

1K
76
74
73
69
85

2K
72
75
77
79
86

4K
71
71
72
74
80

8K
63
63
61
63
73

RPM
1800

Imp. Dia.
320 mm

3
m /hr
8
17
25
33
41

dBA SPL
68
68
70
70
71

63
0
0
0
0
0

125
52
49
43
42
49

250
55
55
55
57
60

500
64
64
65
65
64

1K
64
64
65
66
68

2K
60
54
61
64
65

4K
56
59
60
60
60

8K
47
46
37
44
44

RPM
1800

Imp. Dia.
300 mm

3
m /hr
7
15
23
30
38

dBA SPL
63
66
66
66
67

63
0
0
0
0
0

125
27
31
27
27
46

250
55
52
52
47
54

500
55
62
60
56
59

1K
57
60
60
62
60

2K
47
56
53
56
60

4K
59
61
61
61
61

8K
47
46
51
50
54

173

50 Hz SOUND PRESSURE LEVELS

Pump size: 100x65-315

2/10/1999

Flow
3
m /hr
41
63
94
125
156

Total
Unfiltered
dBA SPL
87
84
82
83
85

63
43
45
42
45
43

125
57
57
56
57
56

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
74
77
80
82
80
71
76
77
80
77
68
74
75
79
75
51
73
75
80
75
68
77
77
81
77

8K
72
70
64
65
70

RPM
3000

Imp. Dia.
320 mm

RPM
3000

Imp. Dia.
300 mm

m /hr
36
55
83
110
138

dBA SPL
78
79
82
82
82

63
37
17
40
42
32

125
34
50
50
50
49

250
68
69
66
59
62

500
67
48
58
68
62

1K
72
74
76
75
76

2K
73
76
79
79
80

4K
70
69
73
73
73

8K
63
59
63
64
63

RPM
3000

Imp. Dia.
280 mm

m /hr
33
50
75
100
125

dBA SPL
79
81
82
82
82

63
11
23
22
32
39

125
25
39
25
52
54

250
69
61
62
49
58

500
68
66
71
75
75

1K
74
76
78
77
77

2K
74
78
78
76
77

4K
71
72
73
70
70

8K
64
64
66
65
65

RPM
1500

Imp. Dia.
320 mm

3
m /hr
9
30
45
60
75

dBA SPL
74
72
74
74
74

63
0
0
0
0
0

125
52
46
32
47
51

250
51
38
52
47
53

500
60
56
46
58
58

1K
70
70
71
71
71

2K
68
67
70
70
69

4K
67
64
64
65
65

8K
60
54
54
51
53

RPM
1500

Imp. Dia.
300 mm

3
m /hr
9
28
43
57
71

dBA SPL
67
72
73
72
72

63
0
0
0
0
0

125
44
45
44
46
47

250
51
41
44
46
49

500
53
52
46
47
59

1K
64
67
70
69
68

2K
62
69
69
69
68

4K
56
61
61
63
62

8K
49
54
54
54
53

174

60 Hz SOUND PRESSURE LEVELS

Pump size: 100x65-315

2/10/1999

Flow
3
m /hr
41
63
94
125
156

Total
Unfiltered
dBA SPL
91
88
86
87
89

63
47
49
46
49
47

125
61
61
60
61
60

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
78
81
84
86
84
75
80
81
84
81
72
78
79
83
79
55
77
79
84
79
72
81
81
85
81

8K
76
74
68
69
74

RPM
3600

Imp. Dia.
320 mm

RPM
3600

Imp. Dia.
300 mm

m /hr
36
55
83
110
138

dBA SPL
82
83
86
86
86

63
41
21
44
46
36

125
38
54
54
54
53

250
72
73
70
63
66

500
71
52
62
72
66

1K
76
78
80
79
80

2K
77
80
83
83
84

4K
74
73
77
77
77

8K
67
63
67
68
67

RPM
3600

Imp. Dia.
280 mm

m /hr
33
50
75
100
125

dBA SPL
83
85
86
86
86

63
15
27
26
36
43

125
29
43
29
56
58

250
73
65
66
53
62

500
72
70
75
79
79

1K
78
80
82
81
81

2K
78
82
82
80
81

4K
75
76
77
74
74

8K
68
68
70
69
69

RPM
1800

Imp. Dia.
320 mm

3
m /hr
9
30
45
60
75

dBA SPL
76
74
76
76
76

63
0
0
0
0
0

125
54
48
34
49
53

250
53
40
54
49
55

500
62
58
48
60
60

1K
72
72
73
73
73

2K
70
69
72
72
71

4K
69
66
66
67
67

8K
62
56
56
53
55

RPM
1800

Imp. Dia.
300 mm

3
m /hr
9
28
43
57
71

dBA SPL
69
74
75
74
74

63
0
0
0
0
0

125
46
47
46
48
49

250
53
43
46
48
51

500
55
54
48
49
61

1K
66
69
72
71
70

2K
64
71
71
71
70

4K
58
63
63
65
64

8K
51
56
56
56
55

175

50 Hz SOUND PRESSURE LEVELS

Pump Size: 125x80-315

10/22/1998

Total
Flow Unfiltered
m3/hr dBA SPL
61
88
118
86
178
88
239
89
299
90

63
0
45
57
60
61

125
61
60
66
69
71

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
83
76
80
80
80
83
74
80
79
76
72
77
84
83
79
78
79
85
84
80
78
81
85
85
82

RPM
3000

Imp. Dia.
320mm

RPM
3000

Imp. Dia.
300 mm

m3/hr
64
130
195
260
285

dBA SPL
83
81
83
86
88

63
40
41
47
51
50

125
58
57
58
61
60

250
73
68
70
72
71

500
75
67
67
76
77

1K
66
63
63
77
81

2K
79
78
81
83
84

4K
77
76
78
80
81

8K
70
68
70
73
74

RPM
3000

Imp. Dia.
280 mm

m3/hr
51
103
154
205
255

dBA SPL
81
79
80
81
83

63
40
30
35
45
43

125
63
55
57
58
57

250
68
65
66
68
68

500
59
59
59
59
59

1K
67
62
62
62
70

2K
78
76
77
79
81

4K
75
74
75
76
77

8K
66
66
67
68
70

RPM
1500

Imp. Dia.
320mm

m3/hr
31
61
91
121
151

dBA SPL
75
77
76
75
75

63
31
32
36
36
33

125
59
59
60
59
60

250
61
61
62
62
61

500
64
66
66
66
65

1K
71
73
73
72
72

2K
68
71
70
68
67

4K
67
66
66
65
64

8K
58
56
56
54
55

RPM
1500

Imp. Dia.
300 mm

m3/hr
30
60
92
120
150

dBA SPL
71
75
76
75
74

63
34
23
37
31
23

125
57
58
59
60
60

250
56
58
61
59
58

500
62
66
67
67
66

1K
68
72
72
72
71

2K
63
69
70
67
66

4K
61
65
66
64
64

8K
48
56
57
52
53

176

8K
75
70
72
73
75

50 Hz SOUND PRESSURE LEVELS

Pump size: 125x100-315

2/10/1999

Flow
3
m /hr
58
115
173
230
288

Total
Unfiltered
dBA SPL
89
84
85
86
87

63
44
44
49
55
57

125
60
56
57
59
63

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
81
80
81
84
79
74
76
77
81
75
70
74
80
82
75
68
74
80
83
75
75
77
81
85
76

8K
73
70
68
66
67

RPM
3000

Imp. Dia.
330 mm

RPM
3000

Imp. Dia.
300 mm

m /hr
50
100
150
200
250

dBA SPL
83
80
80
82
83

63
44
39
41
46
43

125
60
54
56
56
55

250
68
63
66
69
72

500
70
69
66
69
69

1K
79
74
74
78
76

2K
78
78
78
79
80

4K
72
71
70
70
72

8K
63
46
42
44
62

RPM
3000

Imp. Dia.
280 mm

m /hr
43
85
128
170
213

dBA SPL
80
81
82
81
80

63
45
40
32
32
34

125
55
53
32
54
54

250
64
47
53
58
70

500
57
70
71
62
54

1K
76
76
77
77
74

2K
77
77
78
78
77

4K
71
71
72
70
70

8K
65
63
60
59
59

RPM
1500

Imp. Dia.
330 mm

m /hr
17
58
86
115
144

dBA SPL
74
72
73
73
71

63
0
0
41
41
0

125
55
52
46
50
41

250
58
54
53
56
54

500
49
60
59
62
45

1K
70
67
69
70
69

2K
69
68
68
67
65

4K
66
64
64
64
63

8K
59
56
55
55
56

RPM
1500

Imp. Dia.
300 mm

m /hr
16
53
79
105
131

dBA SPL
70
74
72
72
70

63
0
0
0
41
0

125
43
45
49
38
47

250
53
52
55
51
49

500
49
58
60
61
60

1K
67
72
70
70
68

2K
65
68
66
65
58

4K
61
63
62
60
59

8K
52
55
53
52
53

177

60 Hz SOUND PRESSURE LEVELS

Pump size: 125x100-315

2/10/1999

Flow
3
m /hr
58
115
173
230
288

Total
Unfiltered
dBA SPL
93
88
89
90
91

63
48
48
53
59
61

125
64
60
61
63
67

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
85
84
85
88
83
78
80
81
85
79
74
78
84
86
79
72
78
84
87
79
79
81
85
89
80

8K
77
74
72
70
71

RPM
3600

Imp. Dia.
330 mm

RPM
3600

Imp. Dia.
300 mm

m /hr
50
100
150
200
250

dBA SPL
87
84
84
86
87

63
48
43
45
50
47

125
64
58
60
60
59

250
72
67
70
73
76

500
74
73
70
73
73

1K
83
78
78
82
80

2K
82
82
82
83
84

4K
76
75
74
74
76

8K
67
50
46
48
66

RPM
3600

Imp. Dia.
280 mm

m /hr
43
85
128
170
213

dBA SPL
84
85
86
85
84

63
49
44
36
36
38

125
59
57
36
58
58

250
68
51
57
62
74

500
61
74
75
66
58

1K
80
80
81
81
78

2K
81
81
82
82
81

4K
75
75
76
74
74

8K
69
67
64
63
63

RPM
1800

Imp. Dia.
330 mm

m /hr
17
58
86
115
144

dBA SPL
76
74
75
75
73

63
0
0
43
43
0

125
57
54
48
52
43

250
60
56
55
58
56

500
51
62
61
64
47

1K
72
69
71
72
71

2K
71
70
70
69
67

4K
68
66
66
66
65

8K
61
58
57
57
58

RPM
1800

Imp. Dia.
300 mm

m /hr
16
53
79
105
131

dBA SPL
72
76
74
74
72

63
0
0
0
43
0

125
45
47
51
40
49

250
55
54
57
53
51

500
51
60
62
63
62

1K
69
74
72
72
70

2K
67
70
68
67
60

4K
63
65
64
62
61

8K
54
57
55
54
55

178

50 Hz SOUND PRESSURE LEVELS

Pump Size: 200x150-315

1/8/1999

Total
Flow Unfiltered
m3/hr dBA SPL
114
78
228
76
341
76
455
77
468
76

63
44
41
35
31
19

125
62
57
53
58
57

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
63
66
73
74
71
64
65
70
71
68
65
66
69
72
69
63
69
73
72
68
60
67
71
72
68

RPM
1450

Imp. Dia.
356 mm

RPM
1450

Imp. Dia.
330 mm

m3/hr
109
217
326
427
574

dBA SPL
74
73
72
73
70

63
44
42
43
37
39

125
59
53
55
51
54

250
65
67
63
60
60

500
66
66
67
64
66

1K
63
55
56
53
55

2K
69
68
67
68
53

4K
65
65
66
69
65

8K
55
54
56
59
58

RPM
1450

Imp. Dia.
305 mm

m3/hr
102
205
307
408
512

dBA SPL
72
68
67
70
67

63
42
39
42
41
34

125
59
54
53
51
52

250
64
61
59
59
55

500
66
63
63
66
65

1K
55
54
54
56
54

2K
67
61
61
65
53

4K
62
61
58
63
60

8K
54
51
51
52
52

RPM
960

Imp. Dia.
356

m3/hr
82
164
245
327
409

dBA SPL
74
71
71
71
70

63
48
47
36
32
34

125
60
58
51
47
46

250
67
66
57
57
56

500
67
64
64
67
65

1K
68
60
54
67
64

2K
68
65
69
62
64

4K
64
60
63
62
63

8K
53
51
51
51
53

RPM
960

Imp. Dia.
330

m3/hr
73
148
222
296
369

dBA SPL
61
61
68
62
67

63
51
50
41
41
47

125
38
37
37
37
38

250
46
46
46
46
47

500
47
46
46
46
47

1K
53
52
57
53
54

2K
51
50
66
58
65

4K
57
58
60
57
60

8K
50
47
48
48
48

179

8K
61
58
60
59
61

60 Hz SOUND PRESSURE LEVELS

Pump Size: 200x150-315

1/8/1999

Total
Flow Unfiltered
m3/hr dBA SPL
139
82
278
83
418
84
557
83
696
83

63
44
46
41
39
40

125
68
68
62
58
58

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
73
76
78
74
67
72
76
80
74
68
75
79
80
75
68
74
78
79
76
69
74
77
79
74

RPM
1800

Imp. Dia.
356 mm

RPM
1800

Imp. Dia.
330 mm

m3/hr
140
280
418
556
694

dBA SPL
79
79
80
79
82

63
45
43
42
42
36

125
59
57
55
56
57

250
66
65
66
65
65

500
71
69
71
70
75

1K
72
73
76
75
77

2K
74
76
74
74
77

4K
70
71
69
68
73

8K
63
63
62
59
65

RPM
1800

Imp. Dia.
305 mm

m3/hr
123
246
373
488
612

dBA SPL
77
76
79
78
77

63
46
43
41
41
39

125
63
59
55
56
55

250
66
65
66
65
62

500
70
68
71
69
68

1K
72
69
75
74
72

2K
72
72
73
73
74

4K
68
67
68
67
65

8K
61
59
62
59
58

RPM
1200

Imp. Dia.
356 mm

m3/hr
93
187
282
376
468

dBA SPL
75
72
72
72
71

63
49
48
37
32
35

125
61
59
52
48
47

250
68
67
58
58
57

500
68
65
65
68
65

1K
69
61
55
68
65

2K
69
66
70
63
65

4K
65
61
64
63
64

8K
54
52
52
52
54

RPM
1200

Imp. Dia.
330 mm

m3/hr
86
175
264
352
473

dBA SPL
71
69
70
72
67

63
44
41
34
29
35

125
56
51
49
47
45

250
61
58
58
57
57

500
64
63
64
66
61

1K
55
55
55
68
52

2K
68
66
66
67
60

4K
62
62
63
62
62

8K
51
51
52
52
50

180

8K
67
67
65
65
65

50 Hz SOUND PRESSURE LEVELS

Pump size: 250x200-315

11/15/1999

Flow
m3/h
145
290
434
579
722

Total
Unfiltered
dBA SPL
77
80
80
79
78

63
51
50
48
47
47

125
56
59
59
57
56

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
66
70
72
71
68
69
73
76
72
52
70
71
77
74
56
72
72
76
70
59
69
70
73
72
68

RPM
1500

Imp. Dia.
356 mm

RPM
1500

Imp. Dia.
320 mm

m3/h
134
267
400
534
640

dBA SPL
76
73
77
75
73

63
34
34
31
33
23

125
50
41
52
54
51

250
68
65
64
69
69

500
68
62
65
70
66

1K
68
71
73
61
60

2K
71
67
72
61
67

4K
67
58
67
69
65

8K
63
46
44
58
51

RPM
1500

Imp. Dia.
300 mm

m3/h
127
255
383
511
613

dBA SPL
76
74
72
74
72

63
41
42
40
43
41

125
45
44
39
45
49

250
69
67
62
65
59

500
70
65
63
66
62

1K
68
64
65
66
67

2K
70
70
67
69
69

4K
67
65
65
67
57

8K
58
46
52
47
51

RPM
1000

Imp. Dia.
356 mm

m3/h
102
204.4
307
409
511

dBA SPL
74
75
76
75
73

63
48
43
44
33
45

125
56
56
58
61
62

250
64
65
65
67
67

500
65
65
65
67
61

1K
71
71
73
72
66

2K
66
68
67
62
65

4K
65
68
69
60
65

8K
56
57
58
53
57

RPM
100

Imp. Dia.
320 mm

m3/h
91
182
273
363
436

dBA SPL
68
68
68
70
67

63
29
42
28
38
38

125
40
39
41
39
36

250
59
60
65
57
53

500
54
57
52
56
57

1K
59
61
49
67
63

2K
63
60
63
64
51

4K
63
64
59
64
62

8K
48
51
45
52
52

181

8K
61
59
44
53
55

60 Hz SOUND PRESSURE LEVELS

Pump size: 250x200-315

11/15/1999

Flow
m3/h
176
352
528
704
880

Total
Unfiltered
dBA SPL
84
84
81
84
84

63
47
47
47
49
48

125
60
59
59
59
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
75
76
81
76
71
75
80
79
75
71
69
76
76
72
72
71
80
80
75
74
75
78
79
74

RPM
1800

Imp. Dia.
356 mm

RPM
1800

Imp. Dia.
320 mm

m3/h
159
318
477
636
699

dBA SPL
81
79
76
76
77

63
47
45
46
45
40

125
55
41
41
46
53

250
64
66
67
66
64

500
71
71
69
67
69

1K
74
74
69
68
69

2K
78
75
72
73
75

4K
71
68
61
57
60

8K
66
60
52
55
50

RPM
1800

Imp. Dia.
300 mm

m3/h
142
307
449
613
736

dBA SPL
81
77
74
76
77

63
49
45
45
45
45

125
57
52
54
41
53

250
72
63
65
62
65

500
74
69
69
66
68

1K
74
70
62
68
69

2K
76
73
71
73
74

4K
72
69
60
68
69

8K
66
62
54
58
59

RPM
1200

Imp. Dia.
356 mm

m3/h
123
244
366
488
611

dBA SPL
74
76
76
75
76

63
52
51
48
46
42

125
62
60
56
51
52

250
51
60
55
53
53

500
66
67
67
67
68

1K
69
73
72
72
73

2K
68
69
68
67
68

4K
64
66
70
68
68

8K
54
54
49
52
60

RPM
1200

Imp. Dia.
320 mm

m3/h
109
218
327
437
525

dBA SPL
71
67
70
70
69

63
28
31
31
31
33

125
42
33
32
29
46

250
67
51
55
49
61

500
54
53
53
56
53

1K
62
65
63
67
64

2K
53
59
64
67
64

4K
66
58
66
57
62

8K
55
42
47
37
34

182

8K
69
67
65
66
68

50 Hz SOUND PRESSURE LEVELS

Pump size: 125x80-400

12/14/1998

Total
Flow Unfiltered
m3/hr dBA SPL
25
79
48
79
73
80
96
78
120
80

63
40
38
42
43
43

125
61
59
58
58
57

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
60
65
73
74
72
59
66
75
75
71
59
68
75
76
71
60
68
74
74
70
60
70
75
75
71

RPM
1500

Imp. Dia.
400 mm

RPM
1500

Imp. Dia.
380 mm

m3/hr
23
46
68
91
119

dBA SPL
76
78
79
78
80

63
31
24
34
41
35

125
58
58
59
59
60

250
58
59
58
59
65

500
64
66
67
67
73

1K
72
74
75
74
75

2K
71
74
75
73
74

4K
66
68
70
68
69

8K
58
58
59
58
64

RPM
1500

Imp. Dia.
360 mm

m3/hr
22
43
65
87
108

dBA SPL
75
78
79
78
77

63
39
34
41
44
43

125
59
59
58
59
59

250
56
58
59
60
60

500
64
67
68
68
66

1K
73
75
76
75
73

2K
67
71
73
72
72

4K
64
68
70
69
68

8K
56
59
59
59
60

RPM
1000

Imp. Dia.
400 mm

m3/hr
15
32
47
63
77

dBA SPL
68
70
72
71
69

63
39
34
29
35
38

125
55
47
40
49
57

250
53
51
53
54
52

500
57
58
59
60
57

1K
62
63
66
67
63

2K
63
66
68
67
64

4K
61
63
65
64
62

8K
51
52
52
53
51

RPM
1000

Imp. Dia.
380 mm

m3/hr
15
30
44
59
80

dBA SPL
71
68
70
69
70

63
37
34
41
37
38

125
51
41
37
43
50

250
56
50
49
49
51

500
58
57
58
58
60

1K
66
62
65
64
65

2K
67
64
66
64
66

4K
61
61
61
61
60

8K
50
51
52
51
53

183

8K
67
62
61
61
63

60 Hz SOUND PRESSURE LEVELS

Pump size: 125x80-400

12/14/1998

Total
Flow Unfiltered
m3/hr dBA SPL
32
81
65
81
97
82
129
80
162
82

63
42
40
44
45
45

125
63
61
60
60
59

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
62
67
75
76
74
61
68
77
77
73
61
70
77
78
73
62
70
76
76
72
62
72
77
77
73

RPM
1800

Imp. Dia.
400 mm

RPM
1800

Imp. Dia.
380 mm

m3/hr
31
62
93
123
155

dBA SPL
78
80
81
79
81

63
33
26
36
43
37

125
60
60
61
61
62

250
60
61
60
61
67

500
66
68
69
69
75

1K
74
76
77
75
76

2K
73
76
77
75
76

4K
68
70
72
70
71

8K
60
60
61
60
66

RPM
1800

Imp. Dia.
360 mm

m3/hr
30
59
89
118
148

dBA SPL
77
80
81
80
79

63
41
36
43
46
45

125
61
61
60
61
61

250
58
60
61
62
62

500
66
69
70
70
68

1K
75
77
78
77
75

2K
69
73
75
74
74

4K
66
70
72
71
70

8K
58
61
61
61
62

RPM
1200

Imp. Dia.
400 mm

m3/hr
23
46
69
91
114

dBA SPL
70
72
74
73
71

63
41
36
31
37
40

125
57
49
42
51
59

250
55
53
55
56
54

500
59
60
61
62
59

1K
64
65
68
69
65

2K
65
68
70
69
66

4K
63
65
67
66
64

8K
53
54
54
55
53

RPM
1200

Imp. Dia.
380 mm

m3/hr
22
43
65
86
108

dBA SPL
73
70
71
71
72

63
39
36
43
39
40

125
53
43
39
45
52

250
58
52
51
51
53

500
60
59
60
60
62

1K
68
64
65
66
67

2K
69
66
68
66
68

4K
63
63
63
63
62

8K
52
53
54
53
55

184

8K
69
64
63
63
65

50 Hz SOUND PRESSURE LEVELS

Pump size: 150x125-400

2/10/1999

Flow
3
m /hr
55
88
165
220
275

Total
Unfiltered
dBA SPL
83
80
73
74
73

63
41
41
38
36
27

125
66
65
62
60
61

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
66
72
78
80
74
63
61
74
78
70
60
59
69
70
59
64
60
70
69
58
49
61
70
69
58

8K
68
52
49
47
48

RPM
1500

Imp. Dia.
420 mm

RPM
1500

Imp. Dia.
400 mm

m /hr
50
80
150
200
250

dBA SPL
78
76
74
75
72

63
39
43
39
34
38

125
64
64
61
60
61

250
59
60
55
45
50

500
64
63
59
61
61

1K
75
72
69
72
69

2K
74
73
71
71
68

4K
69
61
59
57
55

8K
49
51
50
51
49

RPM
1500

Imp. Dia.
380 mm

m /hr
48
76
143
190
238

dBA SPL
74
76
73
74
73

63
37
44
39
39
39

125
64
63
62
62
62

250
54
56
57
57
59

500
60
62
60
59
63

1K
70
72
70
70
69

2K
69
73
67
70
69

4K
66
60
58
64
64

8K
46
49
44
47
47

185

60 Hz SOUND PRESSURE LEVELS

Pump size: 150x125-400

2/10/1999

Flow
3
m /hr
55
88
165
220
275

Total
Unfiltered
dBA SPL
85
82
75
76
75

63
43
43
40
38
29

125
68
67
64
62
63

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
74
80
82
76
65
63
76
80
72
62
61
71
72
61
66
62
72
71
60
51
63
72
71
60

8K
70
54
51
49
50

RPM
1800

Imp. Dia.
420 mm

RPM
1800

Imp. Dia.
400 mm

m /hr
50
80
150
200
250

dBA SPL
80
78
76
77
74

63
41
45
41
36
40

125
66
66
63
62
63

250
61
62
57
47
52

500
66
65
61
63
63

1K
77
74
71
74
71

2K
76
75
73
73
70

4K
71
63
61
59
57

8K
51
53
52
53
51

RPM
1800

Imp. Dia.
380 mm

m /hr
48
76
143
190
238

dBA SPL
76
78
75
76
75

63
39
46
41
41
41

125
66
65
64
64
64

250
56
58
59
59
61

500
62
64
62
61
65

1K
72
74
72
72
71

2K
71
75
69
72
71

4K
68
62
60
66
66

8K
48
51
46
49
49

186

50 Hz SOUND PRESSURE LEVELS

Pump size: 200x150-400

10/21/1999

Flow
m3/h
111
221
332
443
531

Total
Unfiltered
dBA SPL
85
82
81
80
80

63
49
42
44
41
42

125
72
67
60
60
60

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
68
76
81
80
76
69
74
78
76
69
69
73
77
77
69
69
72
77
75
68
70
72
76
75
69

RPM
1500

Imp. Dia.
410 mm

RPM
1500

Imp. Dia.
380 mm

m3/h
94
187
281
375
450

dBA SPL
79
77
79
79
80

63
44
39
40
42
36

125
57
54
52
53
54

250
69
68
68
68
69

500
70
67
69
69
69

1K
72
71
75
75
75

2K
74
73
73
74
75

4K
70
69
69
69
71

8K
61
55
57
59
60

RPM
1500

Imp. Dia.
360 mm

m3/h
85
170
256
341
409

dBA SPL
77
79
79
80
78

63
43
52
53
53
39

125
44
61
61
60
56

250
68
69
69
71
68

500
68
70
69
70
69

1K
73
75
75
76
75

2K
71
74
76
76
72

4K
64
67
62
63
65

8K
43
56
58
59
54

RPM
1000

Imp. Dia.
410 mm

m3/h
77
154
232
307
368

dBA SPL
75
72
75
75
75

63
40
33
33
35
35

125
57
52
53
52
48

250
66
63
63
62
62

500
69
66
69
68
68

1K
69
55
72
71
72

2K
70
66
67
68
69

4K
67
66
64
66
67

8K
57
50
43
46
50

RPM
1000

Imp. Dia.
380 mm

m3/h
66
131
197
261
313

dBA SPL
72
70
69
71
70

63
42
39
33
31
39

125
44
36
35
41
39

250
63
58
56
55
56

500
59
56
55
55
52

1K
63
63
55
66
60

2K
69
66
66
67
67

4K
65
63
64
64
65

8K
57
54
53
53
54

187

8K
69
61
55
54
62

60 Hz SOUND PRESSURE LEVELS

Pump size: 200x150-400

10/21/1999

Flow
m3/h
136
273
409
545
600

Total
Unfiltered
dBA SPL
90
86
85
84
89

63
44
43
34
46
50

125
80
69
66
68
72

Octave band center frequencies in Hertz


Sound pressure values are in dBA re 20Pa
250
500
1K
2K
4K
82
79
86
83
81
75
77
82
79
76
73
77
81
79
75
72
76
80
77
75
75
79
84
84
81

RPM
1800

Imp. Dia.
410 mm

RPM
1800

Imp. Dia.
380 mm

m3/h
114
227
341
454
545

dBA SPL
84
85
86
86
84

63
51
50
49
47
46

125
71
70
63
60
61

250
78
80
82
81
79

500
77
79
80
81
78

1K
74
79
79
79
79

2K
79
77
78
78
77

4K
74
73
71
71
71

8K
69
66
67
67
65

RPM
1800

Imp. Dia.
360 mm

m3/h
108
216
324
431
517

dBA SPL
81
81
83
83
82

63
45
44
48
48
49

125
67
59
61
52
62

250
72
70
77
75
75

500
73
74
78
77
76

1K
76
78
79
77
77

2K
73
75
75
76
75

4K
71
71
70
67
69

8K
64
62
62
64
65

RPM
1200

Imp. Dia.
410 mm

m3/h
91
182
273
363
436

dBA SPL
79
81
78
79
77

63
45
43
43
45
41

125
62
59
59
61
62

250
64
67
66
64
64

500
71
73
71
72
70

1K
73
77
75
75
73

2K
75
75
71
72
71

4K
71
70
68
67
67

8K
62
53
53
46
56

RPM
1200

Imp. Dia.
380 mm

m3/h
79
159
238
318
382

dBA SPL
76
75
78
76
77

63
38
39
41
33
38

125
52
27
52
53
56

250
66
63
65
64
64

500
62
60
68
55
66

1K
70
70
74
73
73

2K
72
71
72
71
71

4K
66
68
67
66
67

8K
54
50
51
52
54

188

8K
75
68
64
59
76

S-ar putea să vă placă și