Sunteți pe pagina 1din 2

HEAT LOAD FORM (computerized computation)

Prepared by

Name of Job

Galang, John Martin L


S202

Space used for :


Size

### 406.683

ITEM

11.42

4644.31415
SUN GAIN OR
Temp. diff.

AREA OR QUANTITY

55.9444

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

FACTOR

BTU/HOUR

WALLS
255.72916667
WALLS
WALLS
WALLS
ROOF-SUN
0
ROOF-SHADED
0

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

x
x
x
x
x
x

Approve

October 30, 2015


:

local time
Peak Load
Sun time

Estimate for

local time
sun time

Hours of Operation: 10 Hours

x
x
x
x
x

15.2

x
x
x
x
x

0.7605

x
x
x
x
x
x

0.47

x
x
x
x
x

0.54
0.4

646.69
0.00
0.00
0.00
0.00

SOLAR & TRANS. GAIN - WALLS & ROOF


NW
SW
NE
SE

Prop. No.

cu. ft.

SOLAR GAIN -LOSS


GLASS
GLASS
GLASS
GLASS
SKYLIGHT

Date

23.1

CONDITIONS

DB
F

WB
F

%RH
%

DP

Outdoor (OA)

97

81

51

76

135

Room (RM)

75

62.6

50

55

65

Difference

22

XXX

XXX

XXX

70

CFM/PERSON
CFM/SQ. FT
450

=
=

CFM/PERSON
CFM/DOOR
0
CFM/FEET
0

=
=

3858.19
0.00
0.00
0.00
0.00
VENTI-LATION
0.00

GR/LB

OUTDOOR AIR
30

PEOPLE x
SQ. FT. x
CFM VENTILATION =

15

TRANS. GAIN - EXCEPT WALLS & ROOF


ALL GLASS
PARTITION
PARTITION
FLOOR
INFILTRATION

94.6944
300.89583
0
0

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
CFM

x
x
x
x
x

22
17

SWINGING
1124.97
REVOLVING DOORS
2046.09
OPEN DOORS
0
INFIL-TRATION
0.00
EXHAUST FAN
0.00
CRACK
0
0.00
CFM INFILTRATION =

30
850
448

PEOPLE
WATTS
WATTS

220.5
3.41
3.41
x
0.85

SUBTOTAL
STORAGE

SQ. FT

)
SUBTOTAL

SAFETY FACTOR
ROOM SENSIBLE HEAT

SUPPL
Y DUCT
HEAT
GAIN

+
%

OUTDOOR AIR

SUPP
LY
DUCT
LEAK
CFM

+
%

450

FAN
H.P.

22

0.1

E SENS.
6615.00
HEAT
=
FACTOR
2898.50 ESHF
1298.53
ESHF
=
0.00
0.00 ADP
INDICATED ADP
46.5
SELECTED ADP =
46.5
18487.97
DEHUMIDIFIED AIR QUANTITY
0.00
18487.97
(
1
0.1)
75
46.5 F)
=
TEMP RISE
0.00
18487.97
19557.17
EFFECTIVE ROOM SENS. HEAT =
DEHUM CFM
705.984
CFMda
1.08
x
25.65
18487.97 ROOM SENSIBLE HEAT
OUTLET TEMP
=
24.248
F(rm-outlet)
DIFF
1.08
x
705.98

1069.20
SUPPLY AIR QUANTITY
19557.17
SUPPLY CFM

CFM

Gr/lb x
184.5

PEOPLE

LB-HR

SQ. FT x

0.001

Gr/lbs

x
SUBTOTAL

SAFETY FACTOR
SUPPLY DUCT LEAKAGE
OUTDOOR AIR

ROOM LATENT HEAT


%

CFM

450

70

CFM

APPARATUS DEW POINT


19557.17 EFFECTIVE ROOM SENS. HEAT
27234.17 EFFECTIVE ROOM TOTAL HEAT
0.7181

LATENT HEAT

30

450

0.00
1.08

EFFECTIVE ROOM SENSIBLE HEAT

INFILTRATION
PEOPLE
STEAM
APPLIANCES ETC.
ADDITIONAL HEAT GAINS
VAPOR TRANS

CFM OUTDOOR AIR THRU OPERATION =

INTERNAL HEAT
PEOPLE
POWER
LIGHTS
APPLIANCES ETC.
ADDITIONAL HEAT GAINS

Gr/lbs

0.1

0.68

x
EFFECTIVE ROOM LATENT HEAT
EFFECTIVE ROOM TOTAL HEAT

0.00
5535.00 DEHUM CFM
0.00
0.00
0.00
0.00 EDB
5535.00
0.00 LDB
5535.00
o

1.08

ROOM SENSIBLE HEAT


x

CFMsa

0.000

RESULTING ENT. & LVG CONDITIONS AT APPARATUS


+
450
x
(
97
75
705.98 CFM
= 89.0229798
46.5
+
0.1
x
(
89.0229798
46.5
= 50.752298
FROM PSYCH. CHART:
F
F
75

2142.00
7677.00
27234.17

RC

GTH
12000

4.6779

TOTAL AREA

406.6825
4.6779

tons

OUTOOOR AIR HEAT


SQ. FT
SENSIB

LATENT

RETUR
N
DUCT
HEAT
GAIN

450
450

CFMx
CFMx
+

RETUR
N DUCT
LEAK
GAIN

22
70

F
x (
Gr/lb x (
+
%

0.1 BF) x
0.1 BF) x
HP
PUM
P

1.08
0.68

9622.80
19278.00

SUBTOTAL
AN
D
%
PIP

28900.80

GRAND TOTAL HEAT

56134.97

0.00

LB

RC

86.94

omputerized computation)

local time
sun time
Hours of Operation: 10 Hours
GR/LB
135
65
70
OUTDOOR AIR
450
0
450

0
0
0
0
0
CFM
APPARATUS DEW POINT
EFFECTIVE ROOM SENS. HEAT
EFFECTIVE ROOM TOTAL HEAT
0.7181
F
DEHUMIDIFIED AIR QUANTITY
25.65

CFMda
F(rm-outlet)

SUPPLY AIR QUANTITY

CFMsa
CFMda

RESULTING ENT. & LVG CONDITIONS AT APPARATUS


)
)
F

tons

sq. ft
ton

S-ar putea să vă placă și