Alarm Handling
Guideline
Using Moshell Commands
Maria Riordan
7/21/2010
Contents
INTRODUCTION:...................................................................
................................................................................
............. 4
ANTENNA/ASC/RET:................................................................
................................................................................
.......... 5
AuxPlugInUnit_CommunicationLostWithAsc:.........................................
...................................................................... 5
AuxPlugInUnit_CommunicationLostWithRet:.........................................
...................................................................... 5
TmaDevice_LnaDegraded: .........................................................
................................................................................
... 5
TmaDevice_LnaFailure: ..........................................................
................................................................................
....... 6
RetDeviceSet_RetFailure: .......................................................
................................................................................
...... 6
RetDevice_RetFailure:...........................................................
................................................................................
........ 6
RetDevice_ElectricalAntennaTiltOutOfRange:......................................
........................................................................ 7
AscDeviceGroup_GeneralHWError:..................................................
............................................................................ 7
AntennaBranch_AntennaProblemInBranchA: .........................................
..................................................................... 7
AntennaBranch_AntennaProblemInBranchB: .........................................
..................................................................... 8
AntennaBranch_FeederCurrentTooLowInBranchA .....................................
................................................................. 9
AntennaBranch_FeederCurrentTooLowInBranchB .....................................
................................................................. 9
AntennaBranch_FeederCurrentTooHighInBranchA ....................................
............................................................... 10
AntennaBranch_FeederCurrentTooHighInBranchB.....................................
............................................................... 10
PLUG IN UNIT: ..................................................................
................................................................................
............... 12
FcuDeviceGroup_NumberOfHwEntitiesMismatch: .....................................
............................................................... 12
FanDeviceGroup_LeftFanSpeedTooLow:..............................................
...................................................................... 12
AuxPlugInUnit_PiuConnectionLost: ...............................................
............................................................................. 13

TpaDevice_AmplificationError ...................................................
................................................................................
. 13
RuDeviceGroup_GammaUplinkFailure: ..............................................
........................................................................ 13
Plug-In Unit General Problem....................................................
................................................................................
. 14
RaxDeviceGroup_GeneralSwError: .................................................
............................................................................ 14
TxDeviceGroup_GeneralSwError: ..................................................
............................................................................. 14
RaxDeviceGroup_GeneralHwError: .................................................
........................................................................... 15
LICENSE ISSUES: ................................................................
................................................................................
.............. 16
License Key File Fault: ........................................................
................................................................................
......... 16
NodeBFunction_16QamLicenseNotValid:.............................................
...................................................................... 16
Password File Fault: ...........................................................
................................................................................
......... 16
UpLinkBaseBandPool_ULHWLessThanULCapacity: .....................................
............................................................... 17
DownLinkBaseBandPool_DLHWLessThanDLCapacity:....................................
............................................................ 17
NodeBFunction_DlHwUsageExceedsDlLicenseLevel: ..................................
............................................................... 17
NodeBFunction_UlHwUsageExceedsUlLicenseLevel: ..................................
............................................................... 18
TRANSMISSION: ..................................................................
................................................................................
............ 20
Loss of Tracking:...............................................................
................................................................................
........... 20
Loss of Synch Reference Redundancy:.............................................
........................................................................... 20
PDH Loss of Signal: ............................................................
................................................................................
.......... 20
PDH Loss of Frame: .............................................................
................................................................................
........ 21
Loss of Cell Delineation on IMA Link:...........................................
...............................................................................
21
Remote Defect Indication on IMA Link: ..........................................
............................................................................ 22
IMA Link Reception Unusable at Far End:.........................................
.......................................................................... 22
IMA Link Reception Misconnected: ...............................................
............................................................................. 23
IMA Group Insufficient Links:...................................................

................................................................................
... 23
IMA Group Insufficient Links at Far End: .......................................
............................................................................. 24
Heartbeat Failure: .............................................................
................................................................................
.......... 25
MISCELLANEOUS: .................................................................
................................................................................
........... 27
Carrier_RejectSignalFromHardware ...............................................
............................................................................ 27
NbapCommon_Layer3SetupFailure:..................................................
......................................................................... 27
RNC:............................................................................
................................................................................
..................... 29
UtranCell_NbapReconfigurationFailure:...........................................
.......................................................................... 29
NbapDedicated_RncRbsControlLinkDown: ...........................................
..................................................................... 29
UtranCell_ServiceUnavailable:...................................................
................................................................................
. 30
UtranCell_ExternalResourceUnavailable: .........................................
.......................................................................... 30
UtranCell_NbapMessageFailure: ..................................................
.............................................................................. 3
1
EXTRA NOTES: ...................................................................
................................................................................
.............. 32
MTN Configuration Types ........................................................
................................................................................
... 32
RBS 3202 .......................................................................
................................................................................
.............. 32
SMOKE Text Analysis.............................................................
................................................................................
...... 32
Node B Restart Procedure .......................................................
................................................................................
... 32
License Issues on Node B........................................................
................................................................................
.... 32
USEFUL Commands: ...............................................................
................................................................................
......... 33
Checking Performance: ..........................................................
................................................................................
..... 33
Locking and Unlocking site on RNC:..............................................
.............................................................................. 3
3
Miscellaneous: .................................................................
................................................................................
........... 33

INTRODUCTION:
This alarm guide is to help assist in clearing alarms on the RNC and RBS using M
OSHELL commands.
Not all cases will be the same. A few things to note for all alarms are as follo
ws:
1) Ensure that there are no existing REFS open for the site either with SMC or
BSS.
2) Refer to the ALEX Documentation. This will give you a full and clear underst
anding of the alarm
you are dealing with.
3) Acknowledge the alarm in the OSS Alarm List Viewer.
4) Check all associated alarms on RNC and RBS. Check the history of the alarm t
aking note if it is a
re-occurring alarm. (lga | grep <alarm>)
5) Use the guidelines below to clear the alarm.
6) Once alarm has been cleared confirm the site is carrying traffic as normal.
ANTENNA/ASC/RET:
AuxPlugInUnit_CommunicationLostWithAsc:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
CommunicationLostWithAsc
This alarm will generally require an RE to go to site. Communication with the AS
C/RET is lost. The consequence of this
alarm is that planning/optimisation will be unable to make a tilt change to the
affected sector. Connection with the ASC
will need to be restored on site or a replacement ASC will be needed.
If the alarm is inter-failing or re-occurring, the best solution is to swap out
the ASC.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep AuxPlugInUnit_CommunicationLostWithAsc *show history of current alarm
get radio no *confirm if node is carrying traffic
st plug *print state of all plug in units
get xxx *do a get on the disabled proxy number
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the ASC/RET using the proxy number
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels
AuxPlugInUnit_CommunicationLostWithRet:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->

CommunicationLostWithRet
This alarm will generally require an RE to go to site. Communication with the AS
C/RET is lost. The consequence of this
alarm is that planning/optimisation will be unable to make a tilt change to the
affected sector. Connection with the RET
will need to be restored on site or a replacement ASC will be needed.
If the alarm is inter-failing or re-occurring, the best solution is to swap out
the RET.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep AuxPlugInUnit_CommunicationLostWithRet *show history of current alarm
get radio no *confirm if node is carrying traffic
st plug *print state of all plug in units
get xxx *do a get on the disabled proxy number
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the ASC/RET using the proxy number
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels
TmaDevice_LnaDegraded:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
LnaDegraded
This alarm is issued by the TmaDevice Managed Object (MO) when one of the two tr
ansistors amplifying the RF signals in
the Antenna System Controller (ASC) or the AISG/3GPP Tower Mounted Amplifier (AT
MA) fails. It indicates that the LNA
gain in one of the branches on the ASC has degraded. The UL signal will pass, bu
t with decreased level.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
st plug *print state of all plug in units
lpr SectorAntenna=x,AuxPlugInUnit=x *shows associated equipment with the ASC
acl xxx *check what action you can perform on the ASC
acc xxx restartAuxUnit *try restart the ASC/RET using the proxy number
If the alarm does not clear after restarting the ASC an RE will be required to v
isit the site and replace the ASC.
TmaDevice_LnaFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
LnaFailure
The fault is located in the Low Noise Amplifier (LNA), which amplifies the RF si
gnals in the receiver (RX) chain. When the
transistors in one branch have failed, the cell is able to carry traffic as long
as the other branch works, but the RX chain
performance is degraded. The LNA gain in one of the branches in the ASC is lost.

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
st plug *print state of all plug in units
lpr SectorAntenna=x,AuxPlugInUnit=x *shows associated equipment with the ASC
get xxx *use this to show more information about the plug in unit
acl xxx *check what action you can perform on the ASC
acc xxx restartAuxUnit *try restart the ASC/RET using the proxy number
If the alarm does not clear after restarting the ASC an RE will be required to v
isit the site and replace the ASC.
RetDeviceSet_RetFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
RetFailure
This alarm is issued by the RetDevice or RetDeviceSet Managed Objects (MO) when
the Remote Electrical Tilt Unit (RETU)
malfunctions. The RETU is used to tilt the antenna according to the specified an
tenna tilt configuration parameters in the
RET profile.
The causes of the alarm are:
A faulty RETU
The RETU arm is unable to move for environmental reasons, for example, antenna
icing
Antenna and RETU not installed
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lpr SectorAntenna=x,AuxPlugInUnit=2
get xxx *using the proxy number from the above command will show the state of th
e RetDeviceSet
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the RET using the proxy number
If a restart does not clear the alarm an RE will need to go to site and check/re
place the RET unit.
RetDevice_RetFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
RetFailure
This alarm is issued by the RetDevice or RetDeviceSet Managed Objects (MO) when
the Remote Electrical Tilt Unit (RETU)
malfunctions. The RETU is used to tilt the antenna according to the specified an
tenna tilt configuration parameters in the
RET profile.
The causes of the alarm are:
A faulty RETU
The RETU arm is unable to move for environmental reasons, for example, antenna
icing
Antenna and RETU not installed
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected

lpr SectorAntenna=x,AuxPlugInUnit=2
get xxx *using the proxy number from the above command will show the state of th
e RetDeviceSet
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the RET using the proxy number
If a restart does not clear the alarm an RE will need to go to site and check/re
place the RET unit.
RetDevice_ElectricalAntennaTiltOutOfRange:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
ElectricalAntennaTiltOutOfRange
This alarm is issued by the RetDevice Managed Object when the electrical antenna
tilt is out of range. The electrical tilt on
the site is set to a value that the RET and antenna does not support.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
get ret elec *shows the current electrical tilt settings on the sectors
get retdevice tilt *shows the max and min tilt supported by the ret device
lpr SectorAntenna=x,AuxPlugInUnit=2
get xxx *using the proxy number from the above command will show the state of th
e RetDeviceSet
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the RET using the proxy number
If restarting the RET does not clear the alarm
n that the Antenna Type is correct:
get sector antennatype *shows the antenna type
If the alarm still persists an RE will need to
RET Unit.
AscDeviceGroup_GeneralHWError:
RBS Library in ALEX: Operation and Maintenance
GeneralHWError

confirm with Planning/Optimisatio


for each sector
go to site and check/replace the
-> Fault Management -> Alarms ->

This alarm is issued by the ASC. It indicates that the ASC is faulty and needs t
o be restarted or replaced.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lpr SectorAntenna=x,AuxPlugInUnit=1
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the ASC using the proxy number
If the alarm does not clear after restarting the ASC an RE will need to go to si
te and investigate/replace the ASC.
AntennaBranch_AntennaProblemInBranchA:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
AntennaProblemInBranchA
This alarm is issued by the AntennaBranch Managed Object (MO) when one of the fo
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- Antenna Jumper Cable
RBS:
moshell Uxxxx *log onto the node

lt all *load all Managed Objects


alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_AntennaProblemInBranchA *shows history of alarm
st plug *check the current status of the ASC/RET
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC/RET
NOTE:
Equipment=1,SectorAntenna=x,AuxPlugInUnit=1 *ASC
Equipment=1,SectorAntenna=x,AuxPlugInUnit=2 *RET
cabx *get the port number of the ASC for the affected sector
================================================================================
===============
SMN APN PORT
BOARD
GREEN YELLOW RED
P
RODUCT NR
================================================================================
===============
0 12 port_0_dev_4
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_0_dev_4
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_1_dev_10
ASC
steady 16hz
off
K
RY 112 42/3
0 12 port_4_dev_5
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_4_dev_5
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_5_dev_12
ASC
steady 16hz
off
K
RY 112 42/3
0 12 port_8_dev_6
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_8_dev_6
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_9_dev_14
ASC
steady 16hz
off
K
RY 112 42/3
---------------------------------------------------------------------------------------------lhsh 001200/port_1_dev_10 asc vswr *prints the VSWR value for the Antenna Branch
lh asc asc vswr *command to show VSWR for all sectors
If the above commands dont work try:
lh asc dbg vswr 0 get -k
This command gives you the return loss value which can be converted to the desir
ed VSWR value using the following link:
http://www.soontai.com/cal_rtvswr.html
Acceptable value for VSWR should be < 1.5. If the value is higher than this an R
E will need to go to site and
investigate/sweep the affected Antenna Branch.
AntennaBranch_AntennaProblemInBranchB:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
AntennaProblemInBranchB

This alarm is issued by the AntennaBranch Managed Object (MO) when one of the fo
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- Antenna Jumper Cable
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_AntennaProblemInBranchA *shows history of alarm
st plug *check the current status of the ASC/RET
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC/RET
NOTE:
Equipment=1,SectorAntenna=x,AuxPlugInUnit=1 *ASC
Equipment=1,SectorAntenna=x,AuxPlugInUnit=2 *RET
cabx *get the port number of the ASC for the affected sector
================================================================================
===============
SMN APN PORT
BOARD
GREEN YELLOW RED
P
RODUCT NR
================================================================================
===============
0 12 port_0_dev_4
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_0_dev_4
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_1_dev_10
ASC
steady 16hz
off
K
RY 112 42/3
0 12 port_4_dev_5
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_4_dev_5
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_5_dev_12
ASC
steady 16hz
off
K
RY 112 42/3
0 12 port_8_dev_6
RU21
steady 16hz
off
K
RC 118 16/1
0 12 port_8_dev_6
FU12
ON
16Hz
OFF
K
RC 118 17/1
0 12 port_9_dev_14
ASC
steady 16hz
off
K
RY 112 42/3
---------------------------------------------------------------------------------------------lhsh 001200/port_1_dev_10 asc vswr *prints the VSWR value for the Antenna Branch
lh asc asc vswr *command to show VSWR for all sectors
If the above commands dont work try:
lh asc dbg vswr 0 get -k
This command gives you the return loss value which can be converted to the desir
ed VSWR value using the following link:

http://www.soontai.com/cal_rtvswr.html
Acceptable value for VSWR should be < 1.5. If the value is higher than this an R
E will need to go to site and
investigate/sweep the affected Antenna Branch.
AntennaBranch_FeederCurrentTooLowInBranchA
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
FeederCurrentTooLowInBranchA
This alarm is issued by the AntennaBranch Managed Object (MO) when one of the fo
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- RET
- Antenna Jumper Cable
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm
st plug *check the current status of the ASC
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET if disabled RE will need to att
end
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC
If no issues are seen with the ASC and the alarm still persists an RE will need
to go to site and investigate any loose feeder
connections.
NOTE:
Some other parameters to check
get antennabranch supervision *Value of 0 implies
mom . antennaSupervisionThreshold *description of
AntennaBranch_FeederCurrentTooLowInBranchB
RBS Library in ALEX: Operation and Maintenance ->
FeederCurrentTooLowInBranchB
This alarm is issued by the AntennaBranch Managed
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- RET
- Antenna Jumper Cable

no Antenna Supervision.
parameter
Fault Management -> Alarms ->
Object (MO) when one of the fo

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm
st plug *check the current status of the ASC
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET if disabled RE will need to att
end
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC
If no issues are seen with the ASC and the alarm still persists an RE will need
to go to site and investigate any loose feeder
connections.

NOTE:
Some other parameters to check
get antennabranch supervision *Value of 0 implies
mom . antennaSupervisionThreshold *description of
AntennaBranch_FeederCurrentTooHighInBranchA
RBS Library in ALEX: Operation and Maintenance ->
FeederCurrentTooHighInBranchA
This alarm is issued by the AntennaBranch Managed
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- RET
- Antenna Jumper Cable

no Antenna Supervision.
parameter
Fault Management -> Alarms ->
Object (MO) when one of the fo

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm
st plug *check the current status of the ASC
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET if disabled RE will need to att
end
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC
If no issues are seen with the ASC and the alarm still persists an RE will need
to go to site and investigate any loose feeder
connections.
NOTE:
Some other parameters to check
get antennabranch supervision *Value of 0 implies
mom . antennaSupervisionThreshold *description of
AntennaBranch_FeederCurrentTooHighInBranchB
RBS Library in ALEX: Operation and Maintenance ->
FeederCurrentTooHighInBranchB
This alarm is issued by the AntennaBranch Managed
llowing units is faulty or a cable is
faulty or disconnected:
- ASC
- RET
- Antenna Jumper Cable

no Antenna Supervision.
parameter
Fault Management -> Alarms ->
Object (MO) when one of the fo

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
lga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm
st plug *check the current status of the ASC
lst ret *check the current status of the ASC/RET
lst asc *check the current status of the ASC/RET if disabled RE will need to att
end
acl xxx *check what action you can perform on the ASC using the proxy number
acc xxx restartAuxUnit *try restart the ASC
If no issues are seen with the ASC and the alarm still persists an RE will need
to go to site and investigate any loose feeder
connections.

NOTE:
Some other parameters to check
get antennabranch supervision *Value of 0 implies no Antenna Supervision.
mom . antennaSupervisionThreshold *description of parameter

PLUG IN UNIT:
FcuDeviceGroup_NumberOfHwEntitiesMismatch:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
NumberOfHwEntitiesMismatch
This alarm is issued by the FcuDeciceGroup MO when there are too few fans in ope
ration. It could be the cause of a faulty
or disconnected fan unit cable or too few fans installed on site.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lpr AuxPlugInUnit=2,FcuDeviceGroup=1
get xxx *using proxy number from above command will show the number of Fans defi
ned on the site
get . numberoffangroups
An RE will need to go to site and confirm that the number of Fans installed on s
ite matches what is configured. Fan unit
cables will also need to be checked.
FcuDeviceGroup_FanFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
FanFailure
This alarm is issued by the FcuDevice Managed Object when there is a problem wit
h one or more of the fans
controlled by the Fan Control Unit
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
pr AuxPlugInUnit=2
acl xxx *shows what action you can perform on the Fan Control Unit (FCU)
acc xxx restartAuxUnit *restarts the FCU
alt *confirm the alarm has cleared
If the alarm does not clear after restarting the FCU and RE will need to attend
on site.
FanDeviceGroup_LeftFanSpeedTooLow:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
LeftFanSpeedTooLow
The LeftFanSpeedTooLow alarm indicates that there are faults in one or more of f

ollowing units:
BaseBand (BB) Subrack Fan Unit
Radio Frequency (RF) Subrack Fan Unit
Multi-Carrier Power Assembly (MCPA) Subrack Fan Unit
Power Subrack (PS) Fan Unit
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep FanDeviceGroup_LeftFanSpeedTooLow *show history of current alarm
lpr Subrack=2,AuxPlugInUnit=1
st plug *print state of all plug in units
get xxx *using proxy number from above command will show the status of the FAN
cabx *shows the led status of the fan unit
mom AuxPlugInUnit led *description of LED status
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the plug in unit
A red LED showing a steady light indicates a faulty FAN. If the alarm does not c
lear after restarting the unit an RE is
required to attend the site and replace the Fan Unit
AuxPlugInUnit_PiuConnectionLost:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
PiuConnectionLost
This alarm is issued by the AuxPlugInUnit Managed Object (MO) when communication
between one of the Auxiliary Units
(AU) and its device is lost.
Use ALEX to check what actions to perform on the various types of Plug In Units.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep AuxPlugInUnit_PiuConnectionLost *show the history of the current alar
m
st plug *print state of all plug in units
lpr AuxPlugInUnit=x *shows associated equipment with plug in unit
get xxx *use this to show more information about the plug in unit
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the plug in unit
If the alarm does not clear an RE will be required to visit the site.
TpaDevice_AmplificationError
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
AmplificationError
This alarm is issued by the TpaDevice Managed Object (MO) when there is a fault
affecting the Transmit Power Amplifier
(TPA) in a Multicarrier Power Amplifier (MCPA) or a Radio Unit (RU).
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
cabx *will show you what MCPA is faulty if you check the LED status
get cell maxDlPowerCapability *the sector with the faulty MCPA will have a lower
value
st plug *get the proxy number of the MCPA to be restarted
lpr McpaSubrack=x,RbsSlot=x,AuxPlugInUnit=1 *also used to get the proxy number o

r the MCPA
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the MCPA
get cell maxDlPowerCapability *confirm the value has changed this value is calcu
lated by the RBS
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels
get cell=xxxx maximumTransmissionPower *this is a set value on the RNC
This alarm is also associated with the following alarm on the RNC:
UtranCell_NbapReconfigurationFailure
If the alarm does not clear the RE will need to go to site and change the faulty
MCPA.
RuDeviceGroup_GammaUplinkFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
GammaUplinkFailure
This alarm is issued by the Managed Object RuDeviceGroup. The alarm indicates a
failure in one or more of the units in the
gamma uplink path. Cables carry the gamma link between the following: the Baseba
nd Interface (BBIF) and Radio
Frequency Interface (RFIF) boards; the Optical Baseband Interface (OBIF) board a
nd the RRU; the Radio Unit Interface
(RUIF) and the Radio Unit (RU). Between all other boards, the physical connectio
ns are made through the backplane of the
boards.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep RbsSubrack=RU1,RbsSlot=x *see if the RU has been inter-failing
cabx *LED status will indicate what board is faulty
mom AuxPlugInUnit led *description of LED status
st plug *get the proxy number of the faulty unit
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the RU
If the alarm is still present after restarting the unit lock the sector on the R
NC until the RE can attend and replace the RU.
NOTE: Identifying the affected
RbsSubrack=RU1/FU1,RbsSlot=2
RbsSubrack=RU1/FU1,RbsSlot=4
RbsSubrack=RU1/FU1,RbsSlot=6

sector:
A sector
B sector
C sector

If the Radio Unit is faulty the following alarm will be present on the RNC for t
he disabled sector
UtranCell_NbapMessageFailure
call_establishment_error UtranCell=xxxx
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels

lbl cell=xxxxA1 *lock the sector affected by the faulty RU


ldeb cell=xxxxA1 *once the RU has been replaced unlock the sector
Plug-In Unit General Problem
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Plug-In Unit General Problem
The alarm is issued when all defined recovery attempts are performed for the PIU
or contact with the PIU is lost for at least
five minutes.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
lga | grep Subrack=1,Slot=8,PlugInUnit=1 *check the history of the alarm
cab *confirm if there is contact or not with the PIU
st plug *check the state of PIU
acl xxx *check what action you can perform on the PIU using the proxy number
acc xxx manualRestart *try restart the PIU
If theres no contact with the board and the alarm does not clear an RE will be re
quired to go to site and do a hard reset or
replace the board.
RaxDeviceGroup_GeneralSwError:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
GeneralSwError
This alarm can be sent from all Device Groups, all Device Sets, and all Devices.
The RBS EM identifies which Managed
Object (MO) is issuing the alarm. The likely causes of this alarm are the follow
ing:
A software fault
An incorrect version of the software
A faulty configuration, depending on a software error (only when RruDeviceGrou
p issues the alarm)
In this case it is the RAX board that has the problem.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
cab *confirm the RAX boards on the site
st plug *check the state of the RAX boards
acl xxx *check what action you can perform on the board using the proxy number
acc xxx manualRestart *try restart the board
Check that the alarm has cleared. If the alarm is still present an RE will need
to go to site and do a hard
reset or change the RAX board. Confirm the site is carrying traffic.
TxDeviceGroup_GeneralSwError:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
GeneralSwError
This alarm can be sent from all Device Groups, all Device Sets, and all Devices.
The RBS EM identifies which Managed
Object (MO) is issuing the alarm. The likely causes of this alarm are the follow
ing:
A software fault
An incorrect version of the software
A faulty configuration, depending on a software error (only when RruDeviceGrou
p issues the alarm)
In this case it is the TX board that has the problem. As a consequence the capac
ity of the site is decreased.

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
cab *confirm the TX boards on the site
st plug *check the state of the TX boards
acl xxx *check what action you can perform on the board using the proxy number
acc xxx manualRestart *try restart the board
Check that the alarm has cleared. If the alarm is still present an RE will need
to go to site and do a hard reset or change the
TX board. Confirm the site is carrying traffic.
RaxDeviceGroup_GeneralHwError:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
GeneralHwError
This alarm can be sent from all Device Groups, all Device Sets, and all Devices.
The RBS EM identifies which Managed
Object (MO) is issuing the alarm. This alarm indicates that the component is fau
lty and my need to be replaced. The
following alarm UplinkBaseBandPool_UlHwLessThanUlCapacity will also be present on
the RBS. This indicates that there
is less hardware on the site than is licensed for as a result of the faulty RAX
board.
In this case it is the RAX board that has the problem.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
cab *confirm the RAX boards on the site
st plug *check the state of the RAX boards
acl xxx *check what action you can perform on the board using the proxy number
acc xxx manualRestart *try restart the board
Check that the alarm has cleared. If the alarm is still present an RE will need
to go to site and do a hard reset or change the
RAX board. Confirm the site is carrying traffic.
LICENSE ISSUES:
License Key File Fault:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
License Key file Fault
This alarm is triggered when no valid License Key file (LKF) is found on the nod
e. The LKF may be corrupt or have been
deleted.
When investigating this alarm please ensure that there are no open refs (with BS
S) for the site. The site could be in
integration and the license may not be loaded yet.
CASE 1:
BSS are working on the site and license has not been loaded yet.
CASE 2:
No contact with the Node. Check for alarms on transmission. If alarms are presen
t escalate to either Transmission
department or Telkom as necessary.
CASE 3:
Escalate to BSS to install License Key File.
NOTE: For extra notes on installing a LKF see document License Issues on Node B

.
NodeBFunction_16QamLicenseNotValid:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
16QamLicenseNotValid
This alarm is triggered either when the 16QAM modulation license has expired or
the 16QAM modulation license has been
removed.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get . license *confirm the license installed on the node
get . 16qam *shows the feature and license state on the node
mom . featureState16Qam *gives an explanation of the feature
st pp *checks the number of E1s on the site
NOTE: Check the MTN Configuration document to confirm what license should be ins
talled on the site based on the
number of E1s/Hardware. Also confirm with Optimisation what license should be in
stalled on the Node.
If the featurestate16Qam is ACTIVATED and the license state is DISABLED it will
result in the alarm. To clear the alarm set
the featurestate16Qam to DEACTIVATED.
set NodeBFunction featureState16Qam 0 *Sets the feature to DISABLED since no lic
ense is installed on the site
Password File Fault:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Password File Fault
The alarm indicates that the password required at Security Level 1 and 2, for us
er access via Telnet, SSH, FTP, SFTP or a
serial port, was never set or that the locally stored passwd file has been found
to be corrupt.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
passwd; rbs ; rbs *resets the password on the Node B
alt *confirm the alarm has cleared
UpLinkBaseBandPool_ULHWLessThanULCapacity:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
ULHWLessThanULCapacity
This alarm is triggered when the installed license key file defines a capacity t
hat is greater than the available capacity for
DCH given by the installed Random Access and Receiver (RAX) boards. It can also
be triggered due to a HW failure on one
of the RAX boards which decreases the available capacity below the capacity defi
ned by the license key.
A faulty RAX board (see alarm: RaxDeviceGroup_GeneralSwError/ RaxDeviceGroup_Gen
eralHwError) is the general cause
of this alarm however if all RAX boards are operational and showing no errors th
is alarm will need to be escalated to
Planning/Optimisation to consider increasing the UL capacity on the site.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms

get . license *shows the licensed capacity for Channel Elements in the Uplink
get nodebfunction ava *shows the available Channel Elements in the Uplink based
on the available RAX boards
cab *confirm the RAX boards on the site
st plug *check the state of the RAX boards
NOTE:
Use the Product Number (from the cab printout) to search the ALEX document (Produc
t Overview -> Compatibilities for
Hardware and Software) to confirm the number of Channel Elements supported by th
e RAX board.
acl xxx *check what action you can perform on the board using the proxy number
acc xxx manualRestart *try restart the board
If the RAX board restarts without any more alarms confirm that the ULHWLessThanU
LCapacity alarm has also cleared.
alt *confirm alarm has cleared
get nodebfunction ava *the available Channel Elements should now match the licen
sed capacity
If the fault on the RAX board does not clear after a restart an RE will need to
go to site and do a hard reset or replace the
RAX board.
DownLinkBaseBandPool_DLHWLessThanDLCapacity:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
DLHWLessThanDLCapacity
This alarm is triggered when the installed license key file defines a capacity t
hat is greater than the available capacity for
DCH given by the installed Transmitter (TX) boards. It can also be triggered due
to a HW failure on one of the TX boards
which decreases the available capacity below the capacity defined by the license
key.
If all TX boards are operational and showing no errors this will need to be esca
lated to Planning/Optimisation to consider
increasing the DL capacity on the site.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get . license *shows the licensed capacity for Channel Elements in the Downlink
get nodebfunction ava *shows the available Channel Elements in the downlink base
d on the available TX boards
cab *confirm the TX boards on the site
st plug *check the state of the TX boards
NOTE:
Use the Product Number (from the cab printout) to search the ALEX document (Produc
t Overview -> Compatibilities for
Hardware and Software) to confirm the number of Channel Elements supported by th
e TX board.
NodeBFunction_DlHwUsageExceedsDlLicenseLevel:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
DlHwUsageExceedsDlLicenseLevel
This alarm is issued by the NodeBFunction Managed Object (MO) when the licensed
limit has been reached in the RBS.
The cause of the alarm is that the licensed Channel Element (CE) level is reache
d in the RBS.

NOTE:
When a site uses more Channel Element capacity than is licensed a grace period w
ill be triggered along with this alarm.
Once this grace period expires the site will be limited to the licensed capacity
and the alarm will be cleared
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get . license *shows the licensed capacity for Channel Elements
get nodeb ava *shows the available Channel Elements in the uplink/downlink based
on the installed HW
get . grace *shows the grace period left for UL and DL
get . limited *shows if the site is limited to the licensed capacity
Example 1:
In the example below there are 4 days grace period left. Once dlGraceTimeLeft r
eaches 0 the parameter
dlLimitedByLicenseLevel will be set to True. A value of -1 for ulGraceTimeLeft
indicates that the grace period has not
yet been triggered for the UL.
U2575-Ooseinde_VC> get . grace
100723-12:37:46 10.205.75.161 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/10008
================================================================================
==========
MO
Attribute
Value
================================================================================
==========
NodeBFunction=1
dlGraceTimeLeft 4
NodeBFunction=1
ulGraceTimeLeft -1
================================================================================
==========
U2575-Ooseinde_VC> get . limited
100723-12:37:55 10.205.75.161 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/10008
================================================================================
======
MO
Attribute
Value
================================================================================
======
NodeBFunction=1
dlLimitedByLicenseLevel
false
NodeBFunction=1
ulLimitedByLicenseLevel
false
================================================================================
======
Example 2:
In this example the UL and DL grace time has expired (showing a value of 0) and
the parameter ulLimitedByLicenseLevel
and dlLimitedByLicenseLevel are set to True.
U0595-Umgeni_Heights> get . grace
100723-10:50:26 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336
================================================================================

=======
MO
Attribute
Value
================================================================================
=======
NodeBFunction=1
dlGraceTimeLeft 0
NodeBFunction=1
ulGraceTimeLeft 0
================================================================================
=======
U0595-Umgeni_Heights> get . limited
100723-10:50:34 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336
================================================================================
========
MO
Attribute
Value
================================================================================
========
NodeBFunction=1
dlLimitedByLicenseLevel
true
NodeBFunction=1
ulLimitedByLicenseLevel
true
================================================================================
========
In order for this alarm to clear you must wait for the grace period to expire. O
ne other way of clearing the alarm is to
upgrade the license file to match the available Channel Elements. However this w
ill be up to the planner/optimisation
engineer to decide.
In most cases this alarm can be as a result of a spike in CE usage after a site
is brought on air. All users will attempt to do a
location update and use up all resources causing this spike.
NodeBFunction_UlHwUsageExceedsUlLicenseLevel:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UlHwUsageExceedsUlLicenseLevel
This alarm is issued by the NodeBFunction Managed Object (MO) when the licensed
limit has been reached in the RBS.
The cause of the alarm is that the licensed Channel Element (CE) level is reache
d in the RBS.
NOTE:
When a site uses more Channel Element capacity than is licensed a grace period w
ill be triggered along with this alarm.
Once this grace period expires the site will be limited to the licensed capacity
and the alarm will be cleared
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get . license *shows the licensed capacity for Channel Elements
get nodeb ava *shows the available Channel Elements in the uplink/downlink based
on the installed HW
get . grace *shows the grace period left for UL and DL
get . limited *shows if the site is limited to the licensed capacity
Example 1:
In the example below there are 2 days grace period left. Once ulGraceTimeLeft r

eaches 0 the parameter


ulLimitedByLicenseLevel will be set to True. A value of -1 for dlGraceTimeLeft
indicates that the grace period has not
yet been triggered for the DL.
U4574-Elukhanyisweni_High_School> get . grace
100723-11:02:03 10.201.89.97 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25511
================================================================================
===============
MO
Attribute
Value
================================================================================
===============
NodeBFunction=1
dlGraceTimeLeft -1
NodeBFunction=1
ulGraceTimeLeft 2
================================================================================
===========
U4574-Elukhanyisweni_High_School> get . limited
100723-11:02:42 10.201.89.97 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25511
================================================================================
============
MO
Attribute
Value
================================================================================
============
NodeBFunction=1
dlLimitedByLicenseLevel
false
NodeBFunction=1
ulLimitedByLicenseLevel
false
================================================================================
============
Example 2:
In this example the UL and DL grace time has expired (showing a value of 0) and
the parameter ulLimitedByLicenseLevel
and dlLimitedByLicenseLevel are set to True.
U0595-Umgeni_Heights> get . grace
100723-10:50:26 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336
================================================================================
=======
MO
Attribute
Value
================================================================================
=======
NodeBFunction=1
dlGraceTimeLeft 0
NodeBFunction=1
ulGraceTimeLeft 0
================================================================================
=======
U0595-Umgeni_Heights> get . limited
100723-10:50:34 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336
================================================================================
========
MO
Attribute
Value
================================================================================
========
NodeBFunction=1
dlLimitedByLicenseLevel

true
NodeBFunction=1
ulLimitedByLicenseLevel
true
================================================================================
========
In order for this alarm to clear you must wait for the grace period to expire. O
ne other way of clearing the alarm is to
upgrade the license file to match the available Channel Elements. However this w
ill be up to the planner/optimisation
engineer to decide.
In most cases this alarm can be as a result of a spike in CE usage after a site
is brought on air. All users will attempt to do a
location update and use up all resources causing this spike.

TRANSMISSION:
Loss of Tracking:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Loss of Tracking
The alarm is issued when the system clock enters "loss of tracking" mode. The va
lue of the attribute, syncRefStatus is
changed to LOSS_OF_TRACKING.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get 10 *prints the synchronization Managed Object
acl 10 *shows what action you can perform on the MO
acc 10 resetLossOfTracking *resets loss of tracking
When prompted to Enter mo LDN:
Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminal=1,E1PhysPathTerm=pp1
NOTE: To see the values for syncRefStatus and syncRefActivity use the below comm
ands:
mom refstate
mom refactivity
Loss of Synch Reference Redundancy:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Loss of Synch Reference Redundancy
This alarm can be triggered as a consequence of the primary alarm Loss of Tracki
ng. As a consequence of the fault, the
number of available synchronization references is reduced and there is only one
left. Clearing the Loss of Tracking alarm
should clear this alarm.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
get 10 *prints the synchronization Managed Object
acl 10 *shows what action you can perform on the MO
acc 10 resetLossOfTracking *resets loss of tracking
When prompted to Enter mo LDN:
Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminal=1,E1PhysPathTerm=pp1

NOTE: To see the values for syncRefStatus and syncRefActivity use the below comm
ands:
mom refstate
mom refactivity
PDH Loss of Signal:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
PDH Loss of Signal
This alarm is issued by an E1 on the site when the Exchange Terminal (ET) board
cannot detect any signal at the input
port.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1
Consult with Transmission department as for the next steps to take.
PDH Loss of Frame:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
PDH Loss of Frame
This alarm is issued by an E1 on the site when the Exchange Terminal (ET) board
cannot detect any signal at the input
port.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.

http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1
Consult with Transmission department as for the next steps to take.
Loss of Cell Delineation on IMA Link:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Loss of Cell Delineation on IMA Link
This alarm is triggered when the node cannot extract the ATM cells from the PDH
frame. If there are many similar alarms it
is likely that common hardware is at fault. However if there is just one alarm,
the fault is probably with one IMA link.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1
Consult with Transmission department as for the next steps to take.
Remote Defect Indication on IMA Link:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->R
emote Defect Indication on IMA Link
This alarm is triggered when the remote (far end) node has detected a transmissi
on fault on the IMA link. This will also
trigger the alarm IMA Link Reception Unusable at Far End indicating that the link
at the far end has become unusable.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been

triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1
Consult with Transmission department as for the next steps to take. However in m
ost cases this will need to be escalated
to Telkom.
IMA Link Reception Unusable at Far End:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->I
MA Link Reception Unusable at Far
End
This alarm is triggered when the IMA link at the far end becomes unusable. It is
likely that you will also see the alarm
Remote Defect Indication on IMA Link for the same link indicating that the IMA lin
k is faulty.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1

Consult with Transmission department as for the next steps to take. However in m
ost cases this will need to be escalated
to Telkom.
IMA Link Reception Misconnected:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->I
MA Link Reception Misconnected
This alarm is triggered when there is a configuration mismatch between two nodes
. The IMA link in the receive direction is
not connected to the same remote (far end) IMA unit as the other reception links
in the IMA group. It is likely that you will
see one or both of the following alarms: Remote Defect Indication on IMA Link, IMA
Link Reception Unusable at Far End.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA
Group and are waiting to be integrated.
Check on the HS 3G Site planning page to confirm number of links that are actual
ly completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to check
for any active alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
NOTE:
To check for any errors on the E1 links use the following command:
pmx e1 pm m 1
Consult with Transmission department as for the next steps to take. However in m
ost cases this will need to be escalated
to Telkom.
IMA Group Insufficient Links:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->I
MA Link Insufficient Links
This alarm is triggered when one or more of the IMA links have failed. This redu
ces the number of IMA Links in the IMA
group and the required number of links is less than defined.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
get ima required *shows the required number of links needed in the IMA group
CASE 1:

In the below example there are two UNLOCKED and ENABLED E1 links. However there
is only 1 E1 link defined in the IMA
group.
U4784-Vredenburg_WPK_Silo> st pp
100730-12:08:56 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
Proxy Adm State
Op. State
MO
================================================================================
===
110 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp1
111 0 (LOCKED)
0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp2
114 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp3
================================================================================
===
U4784-Vredenburg_WPK_Silo> st ima
100730-12:09:02 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
Proxy Adm State
Op. State
MO
================================================================================
===
17
0 (DISABLED) TransportNetwork=1,AtmPort=1-1-ima1
49
0 (DISABLED) TransportNetwork=1,ImaGroup=1-1-ima1
50
1 (ENABLED) TransportNetwork=1,ImaGroup=1-1-ima1,ImaLink=
1
================================================================================
===
U4784-Vredenburg_WPK_Silo> get ima required
100730-12:22:21 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
MO
Attribute
Value
================================================================================
===
ImaGroup=1-1-ima1
requiredNumberOfLinks 1
================================================================================
===
Check on the HS 3G Site planning page to confirm the number of links that are ac
tually completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
In the above example BSS will be required to do an IMA upgrade and add the 2
nd
working link to the IMA group. You might
also need to contact Transmission and confirm what the correct configuration is
on the DXX.
IMA Group Insufficient Links at Far End:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->I

MA Group Insufficient Links at Far


End
This alarm is triggered when one or more of the IMA links have failed. This redu
ces the number of IMA Links in the IMA
group and the required number of links is less than defined.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms this will indicate what E1/IMA Link the alarm has been
triggered for
st pp *shows the status of the E1s on the site
st ima *shows the status of the IMA links
get ima *shows what IMA Link is associated with a particular E1
get ima required *shows the required number of links needed in the IMA group
CASE 1:
In the below example there are two UNLOCKED and ENABLED E1 links. However there
is only 1 E1 link defined in the IMA
group.
U4784-Vredenburg_WPK_Silo> st pp
100730-12:08:56 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
Proxy Adm State
Op. State
MO
================================================================================
===
110 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp1
111 0 (LOCKED)
0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp2
114 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu
=1,ExchangeTerminal=1,E1PhysPathTerm=pp3
================================================================================
===
U4784-Vredenburg_WPK_Silo> st ima
100730-12:09:02 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
Proxy Adm State
Op. State
MO
================================================================================
===
17
0 (DISABLED) TransportNetwork=1,AtmPort=1-1-ima1
49
0 (DISABLED) TransportNetwork=1,ImaGroup=1-1-ima1
50
1 (ENABLED) TransportNetwork=1,ImaGroup=1-1-ima1,ImaLink=
1
================================================================================
===
U4784-Vredenburg_WPK_Silo> get ima required
100730-12:22:21 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260
================================================================================
===
MO
Attribute
Value
================================================================================

===
ImaGroup=1-1-ima1
requiredNumberOfLinks 1
================================================================================
===
Check on the HS 3G Site planning page to confirm the number of links that are ac
tually completed on site.
http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning
In the above example BSS will be required to do an IMA upgrade and add the 2
nd
working link to the IMA group. You might
also need to contact Transmission and confirm what the correct configuration is
on the DXX.
Heartbeat Failure:
OSS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarm Hand
ling Operational Instruction ->
Heartbeat Failure
This alarm can be triggered when connectivity to the OSS is lost or the site has
gone down due to transmission.
RBS:
moshell Uxxxx *log onto the node
If you cannot MOSHELL to the node check for alarms on the RNC
riorda_m@uas3g3> moshell u2652
__ __ ____ _____
| \/ |/ __ \ / ____|
/ \ | \ / | | | | (___
/ /\ \ | |\/| | | | |\___ \
/ ____ \| | | | |__| |____) |
/_/
\_\_| |_|\____/|_____/
OSS Framework for MoShell-8.0c
/\

Checking ip contact...Not OK
Unable to connect to 10.209.89.241:23
Cannot connect to MO service, exiting...
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels
pmx cell=xxxx pmTotNoRrcC|pmNoSystemRabRe|pmNoRabEstablish|pmNoNormalRabRel|pmNo
FailedAfterAdm -m 1 *confirm
if the site is carrying traffic
CASE 1 Site is operational and carrying traffic but no connection to the node:
If all channels are unlocked and enabled, the site is carrying traffic and no al
arms are present on the RNC escalate this fault
to Transmission/IP Routing. In this case VC32 and VC33 (used for O&M connectivit
y) will need to be checked by
Transmission. Transmission will possibly need to recreate these VCs as they are
hanging.
Use the command traceroute <nodeipaddress> to confirm where the problem is before
escalating to Transmission. The
traceroute command shows where the IP packet stops in the network, either at the

DXX or IP router.
riorda_m@uas3g3> traceroute 10.204.78.145
traceroute: Warning: Multiple interfaces found; using 10.217.12.16 @ ce1
traceroute to 10.204.78.145 (10.204.78.145), 30 hops max, 40 byte packets
1 10.217.12.252 (10.217.12.252) 0.614 ms 0.349 ms 0.279 ms
2 10.195.17.165 (10.195.17.165) 1.043 ms 0.878 ms 0.901 ms
3 10.195.17.13 (10.195.17.13) 0.952 ms 0.816 ms 0.844 ms
4 10.90.217.5 (10.90.217.5) 1.418 ms 0.991 ms 90.119 ms
5 10.90.250.14 (10.90.250.14) 1.840 ms 6.803 ms 1.097 ms
6 10.90.204.6 (10.90.204.6) 1.317 ms 1.131 ms 0.938 ms
7 10.204.47.252 (10.204.47.252) 0.855 ms 0.859 ms 0.729 ms
8 10.204.47.230 (10.204.47.230) 1.505 ms 1.504 ms 1.940 ms
9 10.204.78.145 (10.204.78.145) 7.887 ms 7.250 ms 8.814 ms
riorda_m@uas3g3>
CASE 2 Site is DISABLED and there are alarms present on the RNC:
If the channels on the RNC are UNLOCKED and DISABLED and there are alarms presen
t on the RNC it is more than likely a
problem on the Transmission side and will need to be escalated to TX or Telkom b
ased on the alarms present on the DXX.
Possible RNC Alarms:
NbapDedicated_RncRbsControlLinkDown transmission_error
_View_Estates,NbapDedicated=1
UtranCell_ServiceUnavailable
unavailable

IubLink=Iub_U2652-Bay
UtranCell=2652A1

UtranCell_ServiceUnavailable

unavailable

UtranCell=2652B1

UtranCell_ServiceUnavailable

unavailable

UtranCell=2652C1

CASE 3 New Site


Check in REMEDY if this is a new site. Generally a new site that is not yet full
y integrated will display the Heartbeat Failure
alarm as it is not yet connected on the OSS.
MISCELLANEOUS:
Carrier_RejectSignalFromHardware
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
RejectSignalFromHardware
This alarm is triggered by the Carrier Managed Object. This alarm can be issued
for the AIU/sAIU, FU, MCPA, RFIF board,
RRU, RU, TRX board or the TX board. If none of the boards are faulty it could be
related to a frequency configuration issue.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
cabx *check the equipment on the site (particularly the RU and FU)
get . fqband *check the highedge and lowedge of the Antenna Branch
Contact optimisation/planning to confirm that the UARFCNs and high and low edges
are set correctly. If they are set
correctly restart the RU relevant to the affected sector.
st plug *shows the plug in units.
acl xxx *check what action you can perform on the PIU using the proxy number
acc xxx manualRestart *try restart the PIU

NOTE: Identifying
RbsSubrack=RU/FU,
RbsSubrack=RU/FU,
RbsSubrack=RU/FU,

the affected sector:


RbsSlot=2 A sector
RbsSlot=4 B sector
RbsSlot=6 C sector

RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels some carriers may be disabled
get cell=xxxx uarfcn *displays the DL and UL frequencies set for each carrier
The following alarm may be present on the RNC:
UtranCell_NbapMessageFailure
NbapCommon_Layer3SetupFailure:
RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
Layer3SetupFailure
This alarm is issued by the NbapCommon Managed Object. It is issued for the Node
B Application Protocol (NBAP)
Common. The likely cause is a communication failure between the RBS and RNC. The
following alarm,
UtranCell_ExternalResourceUnavailable could also be present on the RNC for the aff
ected cells.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels all cells will be DISABLED and also NbapCommo
m on the IubLink
================================================================================
========
14622 1 (UNLOCKED) 1 (ENABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place
14624
0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,N
odeSynch=1
14625 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,N
bapCommon=1
14626 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,N
bapDedicated=1
22656 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1
22669 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Hsdsch=1
22670 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Hsdsch=1,Eul=1
22684 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Rach=RACH
22685 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Pch=PCH
22695 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Fach=1
================================================================================
========
lbl Iublink_Iub_Uxxxx *block the IubLink
GERNC1> lbl Iublink=Iub_U2141
================================================================================
===

14622 RncFunction=1,IubLink=Iub_U2141-Adgam_Place
14625 RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapCommon=1
14626 RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapDedicated=1
================================================================================
===
ldeb Iublink_Iub_Uxxxx *deblock the IubLink
lst .xxxx confirm the channels are UNLOCKED and ENABLED
Confirm the alarm has cleared on the RBS. If the alarm is still present escalate
to Transmission.
RNC:
UtranCell_NbapReconfigurationFailure:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UtranCell_NbapReconfigurationFailure
RBS does not provide the configured output power due to some internal hardware p
roblems. Check the RBS for any HW
faults, generally with the MCPA units.
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels
get cell=xxxx maximumTransmissionPower *this is a set value on the RNC
RNC will internally set a reference value representing the previously configured
maximumTransmissionPower in the cell.
An alarm will be issued if the RBS reports a degradation of its maxPowerCapDl be
low 2dB.
This alarm can be associated with the following alarm on the RBS:
TpaDevice_AmplificationError
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
cabx *will show you what MCPA is faulty if you check the LED status
get cell maxDlPowerCapability *the sector with the faulty MCPA will have a lower
value
st plug *get the proxy number of the MCPA to be restarted
lpr McpaSubrack=x,RbsSlot=x,AuxPlugInUnit=1 *also used to get the proxy number o
r the MCPA
acl xxx *check what action you can perform on the proxy number
acc xxx restartAuxUnit *try restart the MCPA
get cell maxDlPowerCapability *confirm the value has changed this value is calcu
lated by the RBS
If the alarm does not clear the RE will need to go to site and change the faulty
MCPA.
NbapDedicated_RncRbsControlLinkDown:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
NbapDedicated_RncRbsControlLinkDown
This alarm is triggered when there is a temporary disturbance or interruption in
the Iub link . It is also generally

associated with the alarm UtranCell_ServiceUnavailable as all Utrancells will be


DISABLED.
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels cells will be UNLOCKED and DISABLED
This alarms indicates a problem with Transmission. It will need to be either esc
alated to the Transmission department or
Telkom. When this alarm is present you will be unable to Moshell onto the RBS.
Check the DXX web reporter for any current alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
Once the Transmission issue has been cleared, confirm that all cells and channel
s are UNLOCKED and ENABLED and the
site is carrying traffic.
UtranCell_ServiceUnavailable:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UtranCell_ServiceUnavailable
This is a secondary alarm and is triggered when there is a problem with the NBAP
signalling on the Transmission link. It is
associated with the alarm NbapDedicated_RncRbsControlLinkDown
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels cells will be UNLOCKED and DISABLED
This alarm could indicate a problem with Transmission. It will need to be either
escalated to the Transmission department
or Telkom.
Check the DXX web reporter for any current alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
UtranCell_ExternalResourceUnavailable:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UtranCell_ExternalResourceUnavailable
This alarm is triggered by the Utrancell Managed Object. It is issued for the No
de B Application Protocol (NBAP) Common.
The likely cause is a communication failure between the RBS and RNC. The followi
ng alarm, NbapCommon_
Layer3SetupFailure could also be present on the RBS.
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels all cells will be DISABLED
Check the RBS for any alarms.

RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
This alarm could point to a problem with Transmission. It will need to be either
escalated to the Transmission department
or Telkom.
Check the DXX web reporter for any current alarms.
http://10.200.31.30/dll/w3rt.dll
Login: ESA
Password: ESA
UtranCell_RBSLocalCellNotAdded:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UtranCell_RBSLocalCellNotAdded
This alarm is triggered when the RNC is trying to activate the UTRANCELL but is
unable to as there is a mis-configuration
with the RBS Local Cell on the RBS. The alarm UtranCell_NbapMessageFailure could
also be present for the affected
sectors.
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels cells will be UNLOCKED and DISABLED
get cell=xxxx cid *check the Cell ID on the RNC
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms and confirm what sector is affected
get rbslocalcell cellid *check the Cell ID on the RBS and confirm the mismatch
Check the FACTs page to confirm the correct Cell ID to be used CI Allocation Look
up
http://10.217.201.232/facts/report/CI_TRANSLATION/CI_TRANSLATION_LOG
If the RBS that has the incorrect values use the following command to correct it
:
set rbslocalcell=SXCX localCellId=xxxxx *corrects the Cell ID on the RBS
NOTE:
S1C1 Sector 1,Carrier1
S1C2 Sector1,Carrier2 etc.....
If the RNC has the incorrect value use the following command to correct it:
set cell=xxxxA1 cid=xxxxx *corrects the Cell ID on the RNC
Confirm alarm has cleared and the cells are UNLOCKED and ENABLED.
Finally be sure to save a CV see Node B Restart Procedure for help on creating a
CV.
cvls
cvms [cvname_date_time][ursername][comment]
UtranCell_NbapMessageFailure:
RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->
UtranCell_NbapMessageFailure
This alarm can be triggered when the RBS cannot fulfil the request to set up a U
TRAN Cell issued by the RNC. The RBS will

need to be checked for any alarms.


RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels all cells will be DISABLED
Check the RBS for any alarms.
RBS:
moshell Uxxxx *log onto the node
lt all *load all Managed Objects
alt *show current alarms
CASE 1 Hardware Failure on RBS:
A faulty TX board on the RBS can cause the untrancells on the RNC to be DISABLED
. See alarm Plug-In Unit General
Problem.

EXTRA NOTES:
MTN Configuration Types
MTNCONFIG V1.7
B.xls
RBS 3202
RBS3202 Snapshot.docx
SMOKE Text Analysis
SMOKE TEXT
Investigation.docx
Node B Restart Procedure
Node B Restart
Procedure.ppt
License Issues on Node B
License Issues on
Node B.ppt
USEFUL Commands:
Checking Performance:
RNC:
pmx cell=xxxx pmtotnoutranrejrrcconnreq|pmNoFailedAfterAdm -m 1 *shows rejection
s and failures for the last
hour
pmx cell=xx pmTotNoRrcC|pmNoSystemRabRe|pmNoSysRelSpeech|pmNoRabEstablish|pmNoNo
rmalRabRel|pmNoFailedAfterAdm
-m 1
pmx utrancell=xxxx pmCellDowntime -m 4 *shows downtime for last 4 hours
pmr *displays all the predefined performance reports on the RNC

pmom . <countername> *gives a description of a specific counter


pmom . pmCellDowntimeAuto
mom . <parameter> *gives a description of a particular parameter
pmx plug processorload -m 1 *shows processor load on individual boards
RBS:
pmx e1 pm m 1 *shows the errored seconds and severely errored seconds for the E1
links over the last hour
pgets e1 *shows the current errors on the E1 links
pmx aal2ap pmunsuc -m 2 *show all unsuccessful attempts across the aal2 paths fo
r all classes
pmx edch pmnoallowedeul
pgets *shows all active counters on the RBS
pmr *displays all the predefined performance reports on the RBS
get radio no *shows the current number of active radio links
Locking and Unlocking site on RNC:
RNC:
moshell XXRNCX *log onto the RNC
lt all *load all Managed Objects
alt *show current alarms
lst .xxxx *show status of channels confirm if site has one or two carriers
bls cell=xxxx *soft blocks the cells takes 5 minutes
lbl cell=xxxx *blocks all the channels
lst .xxxx *confirm the channels are LOCKED and DISABLED
ldeb cell=xxxx *unlock cells and channels one sector at a time
lst .xxxx *confirm the channels are UNLOCKED and ENABLED
Miscellaneous:
ala *shows current alarms WITH details
altk *shows current alarms UNACKNOWLEDGED and ACKNOWLEDGED
get 0 *shows equipment type
license key *shows licenses installed on the node
cvls *prints configuration version on the node