Sunteți pe pagina 1din 4

ERGON ENERGY

SPECIALIST PLANT SERVICES

POWER TRANSFORMER LOAD LOSS AND IMPEDANCE


Project No
Manufacturer

Works Order No
Serial No

Rating

KVA

Plant
Number
(SPN)

Voltage Ratio

LOAD LOSS AND IMPEDANCE CALCULATIONS

Input Data in yellow cells


Calculated results in green cells

HV Winding Resistance
HV Resistances:
A
Ohms
B
Ohms
C
Ohms

Av.Temp
C
C
C

Resist.@ Test Temp.


0.00000
Ohms
0.00000
Ohms
0.00000
Ohms
Average Resist.@ Test Temp.
0.00000
Ohms

LV Winding Resistance
LV Resistances:
a
Ohms
b
Ohms
c
Ohms

Av.Temp
C
C
C

Resist.@ Test Temp.


0.00000
Ohms
0.00000
Ohms
0.00000
Ohms
Average Resist.@ Test Temp.
0.00000
Ohms

Transformer Details:

Tap No.

Rating:
HV Voltage:
LV Voltage:

Volts B

Volts C

KVA
Volts
Volts

#DIV/0!
#DIV/0!

Amps
Amps

Meter Readings:
Voltage
Volts A

Av.Volts=
Power
Watts A

Total Watts=

0.0 Volts

Watts B

Check this is the latest Process Zone version before use.

Current
Amps A

Amps B

Av. Amps=

Watts C

Watts

Page 1 of 2

Amps C

0.00 Amps

Test Temperature
Top Rad.
Bot.Rad.

Av.Temp=

0.0

Form SP0504C06 Ver 2

Ergon Energy Corporation Limited ABN 50 087 646 062


Ergon Energy Queensland Pty Ltd ABN 11 121 177 802

ERGON ENERGY
SPECIALIST PLANT SERVICES
POWER TRANSFORMER LOAD LOSS AND IMPEDANCE
Project No
Manufacturer

0
0

Rating

Works Order No
Serial No

0 KVA

0
0

Voltage Ratio

Plant
Number
(SPN)

Load Loss and Impedances Calculations:


1.5 HV IR at Rated Current at Load Loss Temp.:
1.5 LV IR at Rated Current at Load Loss Temp.:
Total IR at Rated Current at Load Loss Temp.:
Measured Load Loss at Test Current at Load Loss Temp.:
Calc. Load Loss at Rated Current at Test Temp.:
Eddies and Strays at Test Temp.:
Eddies and Strays at 75 C :
Total IR at 75 C :

#DIV/0!
#DIV/0!
#DIV/0!
0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Total Load Loss at 75 C

#DIV/0! Watts

Average Impedance Volts at Test Current :


Average Impedance Volts at Rated Current :
Impedance Voltage % at Test Temp.:
Resistance Voltage % at Test Temp.:
Reactance Voltage % :
Resistance Voltage % at 75 C :

0.0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Impedance Voltage % at 75 C :

#DIV/0! %

TESTED BY:

__________

__ DATE:

___/___/___

SUPERVISOR:

__________

__ DATE:

___/___/___

ENGINEER:

__________

__ DATE:

___/___/___

Check this is the latest Process Zone version before use.

Page 2 of 2

Ergon Energy Corporation Limited ABN 50 087 646 062


Ergon Energy Queensland Pty Ltd ABN 11 121 177 802

Watts
Watts
Watts
Watts
Watts
Watts
Watts
Watts

Volts
Volts
%
%
%
%

Form SP0504C06 Ver 2

S-ar putea să vă placă și