U.S.rebarsizes:Imperialbardesignationsrepresentthebardiameterin
fractionsof1/8inch,suchthat#8=8/8inch=1inchdiameter.Area=(bar
size/9)2suchthatareaof#8=(8/9)2=0.79inch.Thisappliesto#8barsand
smaller.Largerbarshaveaslightlylargerdiameterthantheonecomputedusing
the1/8inchconvention.

Floatingslabfoundation
Rebarsizes

Imperial

Woodbeamspantables

BarSize

Showerinstallation
Smokedfishrecipes

"Soft"

Weight Weight

Metric
(lb/ft) (kg/m)
Size

Nominal Nominal Nominal Nominal


Diameter Diameter Area
Area
(in)

(mm)

(in) (mm)

#3

#10

0.376

0.561

0.375=
3/8

9.525

0.11

71

#4

#13

0.668

0.996

0.500=
1/2

12.7

0.20

129

#5

#16

1.043

1.556

0.625=
5/8

15.875

0.31

200

#6

#19

1.502

2.24

0.750=
3/4

19.05

0.44

284

#7

#22

2.044

3.049

0.875=
7/8

22.225

0.60

387

#8

#25

2.670

3.982

1.000=
8/8

25.4

0.79

509

#9

#29

3.400

5.071

1.128

28.65

1.00

645

#10

#32

4.303

6.418

1.270

32.26

1.27

819

#11

#36

5.313

7.924

1.410

35.81

1.56

1006

#12

#40

6.424

9.619

1.50

38.1

1.76

1140

#14

#43

7.650

11.41

1.693

43

2.25

1452

#18

#57

13.60

20.284

2.257

57.33

4.00

2581

Europeansizes:Metricbardesignationsrepresentthenominalbardiameterin
millimetres.BarsinEuropewillbespecifiedtocomplywiththestandardEN
10080.
Unitweightsforrebarorreinforcingbarlength11,75meters.Rebarweighttable
forreinforcingbarsfrom5,5mmto32mm.

1meter
1rebars
rebar
rebarweights weights11,75
size
(kg)
m(kg)
(mm)

KWWSGRPGDFKDGRPUXUHEDUKWPO

lengthfor1
tonnofsteel
rebars

5,5

0,187

2,19

5347

6,0

0,222

2,60

4504

8,0

0,395

4,64

2531`

10,0

0,617

7,25

1620

12,0

0,888

10,43

1126

14,0

1,210

14,21

826





6WHHOUHEDUVL]HVDQGZHLJKWVFKDUWV

16,0

1,580

18,56

633

18,0

2,000

23,50

500

20,0

2,470

29,00

405

22,0

2,980

35,00

335

25,0

3,850

45,23

260

28,0

4,830

56,75

207

32,0

6,310

74,14

158

6WHHOUHEDUIRUPXOD
Therearefourmainrulesforsteelreinforcedconcretebeams:
1.Tocounttheheightofthereinforcedconcretebeamdevidethegaplengthby
20.Forexample:thegapis4meters.Thminimumheightoftheconcretebeam
shouldbe4/20=0,2meter
2.Tocountthewidthoftheconcretebeam:Multiplytheheightby5anddevide
by7.Forexample:thebeamheightis0,2meter.0,2x5/7=0,14m.
3.Thebeamshouldbeenforsedwithatleast4steelroundbarsd1214intwo
levels.
4.Theconcreteshouldbeappliedallvolumeatoncewithoutbigwaitinggaps.
ShallowfoundationdepthFloatingslabfoundation
Dicslaimer:allinformationprovidedatthatpageareforprivateuseonlyand
shouldbeverifiedbythecertifiedengineerineachcaseofconstruction.

|rebarweights2014

KWWSGRPGDFKDGRPUXUHEDUKWPO



S-ar putea să vă placă și