Pinch Analysis Spreadsheet

TABLE OF CONTENTS:
INPUT Input Data
PT Problem Table & Cascade
CC Composite Curves
SCC Shifted Composite Curves
GCC Grand Composite Curve
GRID Grid Diagram
AS Actual Streams
AT Actual Intervals Table
SS Shifted Streams
ST Shifted Intervals Table
DTMIN Varying dTmin global
A1
A2

Set-up and conversions


Plot tables

Input problem data, i.e. stream temperatures, stream names, stream propertie
Problem table, heat cascade, pinch identification, problem type, min utility requ
Composite curve plot.
Shifted composite curve plot.
Grand composite plot.
Schematic showing hot and cold shfted streams and the pinch location.
Schematic showing actual streams.
Calculation table for actual composite curves.
Schematic showing shifted streams.
Calculation table for shifted composite curves.
Pinch analysis over a range of dTmin values.
Configuration page listing conversion factors.
Tabulation of plot values.

res, stream names, stream properties and dTmin criteria.


fication, problem type, min utility requirements.

treams and the pinch location.

ves.

rves.
ues.

ors.

Input Data
1. Select Input Method from the Dropdown list:

Mass Flowrate & Specific Heat Capacity

2. Input Global dTmin & select input temperature units:

10

3. Select appropriate units for the input data from the drop down lists below (E15/F15).
4. Input data: Stream Name, Temperatures & Heat/Flow Data (max 50 streams).
5. Select desired output unit set:
Stream
Name
1
2
3
4
5
6
7
8
9
10

Supply
Temperature
C
1369
800
504
25
42
350
337
25
242
243

Target
Temperature
C
77
370
42
250
350
500
800
242
243
500

dT Min
Contrib
C
5
5
5
5
5
5
5
5
5
5

SI-based (kW/K)
Mass Flowrate
kg/s
62.760
36.130
36.130
57.870
8.350
8.350
36.130
60.200
60.200
60.200

Specific Heat
Capacity
kJ/kgK
1.32
2.75
4.91
1.03
2.69
3.47
2.6
4.85
1749.46
2.29

Flowrate & Specific Heat Capacity


C
lists below (E15/F15).

x 50 streams).

Requires Input Optional Input Calculation cell -

sed (kW/K)
Heat Flow
kW
107033.4144
42723.725
81958.0146
13411.3725
6918.142
4346.175
43493.294
63357.49
105317.492
35429.506

Stream
Type
HOT
HOT
HOT
COLD
COLD
COLD
COLD
COLD
COLD
COLD

Supply
Shift
C
1364.0
795.0
499.0
30.0
47.0
355.0
342.0
30.0
247.0
248.0

Target
Shift
C
72.0
365.0
37.0
255.0
355.0
505.0
805.0
247.0
248.0
505.0

Problem Table & Cascade


Shift
Temperature
C
1364

T(i+1)-Ti

mCpnet

dH

kW/K

kW

559

82.8432

46309.3488

surplus

10

-11.0948

-110.948

demand

290

88.2627

25596.183

surplus

-78.5698

-471.4188

demand

134

98.8285

13243.019

surplus

10

-0.529

-5.29

demand

13

5.984

77.792

surplus

87

99.922

8693.214

surplus

40.3159

282.2113

surplus

10

-105139.3181

-105139.3181

demand

11

175

-113.7961

-19914.3175

demand

12

25

-196.6393

-4915.9825

demand

13

10

-174.1778

-1741.778

demand

14

-351.5761

-2461.0327

demand

Interval

Infeasible Cascade

Feasible Cascade

46309.35

-110.948

25596.18

-471.4188

13243.02

-5.29

77.792

8693.214

282.2113

-105139

-19914.32

-4915.983

-1741.778

-2461.033

46309.349

-110.948

25596.183

-471.4188

13243.019

-5.29

77.792

8693.214

282.2113

-105139.3

-19914.32

-4915.983

-1741.778

-2461.033

805
795
505
499
365
355
342
255
248
247
72
47
37
30

PINCH

0
46309
46198
71795
71323
84566
84561
84639
93331.9
93614
-11525
-31440
-36356
-38097
-40558

40558
86868
86757
112353
111881
125125
125119
125197
133890
134172
29033
9118.8
4202.8
2461
0

Hot Pinch
Cold Pinch
Min Hot Utility
Min Cold Utility

35 C
25 C
40558.32 kW
0.0 kW

SINGLE PINCH PROBLEM


0
THRESHOLD PROBLEM

Actual Temperature (C)

Hot and Cold Composite Curves

1600

1400

1200

1000

800

600

400

200

Heat Flow Actual Temperature (C)


Heat Flow Actual Temperature (C)
Heat Flow(Actual Temperature (F)
0 (Mbtu(IT)/hr)
Heat Flow

50000

100000

150000
Heat Flow (kW)

200000

250000

300000

Shifted Temperature (C)

Shifted Hot and Cold Composite Curves


1600

1400

1200

1000

800

600

400

200

Heat Flow Shifted Temperature (C)


Heat Flow Shifted Temperature (C)
Heat Flow Shifted Temperature (F)
0 (Mbtu(IT)/hr)
Heat Flow

50000

100000

150000
Heat Flow (kW)

200000

250000

300000

Grand Composite

Shifted Temperature (C)

1600

1400

1200

1000

800

600

400 F Shifted Temperature (C)


Net Heat
Net Heat F Shifted Temperature (C)
Net Heat F Shifted Temperature (F)
Net Heat Flow (Mbtu(IT)/hr)
200

0
0

20000

40000

60000

80000

100000

Net Heat Flow (kW)

120000

140000

160000

Grid Diagram
Interval

10

11

12

13

14
30

37

47

72

247
|

248
|

255
|

342
|

355

|
|

|
|
|

|
|

|
|

|
|
|
|

|
|
|
|

|
|

|
|
|

|
|
|
|

|
|

|
|

|
|

|
|

|
|
|

|
|

|
|

365
|

499
|

|
|
|

COLD

137.858

35429.506

COLD

10

105317.492

105317.492

COLD

COLD

291.97

93.938

63357.49

43493.294

505

COLD

COLD

28.9745

22.4615

4346.175

6918.142

795

COLD

HOT

59.6061

177.3983

13411.3725

81958.0146

HOT

HOT

99.3575

805

82.8432

42723.725

107033.414

1364

Shifted
Temp (C)

mCp (kW/K)

Heat Flow
(kW)

PINCH

Stream
Name

Stream
Heat Flow (kW)
Actual Temp
Interval
(C)
1369
1
800
2
504
3
500
4
370
5
350
6
337
7
250
8
243
9
242
10
77
11
42
12
25

1
82.8432

2
99.3575

3
177.3983

4
59.6061

5
22.4615

6
28.9745

7
93.938

8
291.97

HOT

HOT

HOT

COLD

COLD

COLD

COLD

COLD

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

|
|
|
|
|

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

|
|
|
|
|
|
|
|
|

|
|
|
|
|
|
|
|
|
|
|

|
|
|

9
10
105317.492 137.858
COLD

|
|
|
|
|
|
|
|
|

|
|
|
|
|

COLD

|
|
|
|
|
|
|
|
|

Actual Intervals Table


Actual Temperature

T(i+1)-Ti

CpHot

dHHot

kW/K

kW

1369

CpCold

dHCold

kW

kW/K

kW

0.0

0.0

93.938

###

93.938

375.752

260.7705

###

260.7705

5215.41

254.2575

###

160.3195

###

219.9256

###

###

###

374.0376

###

374.0376

###

351.5761

###

Cold
Duty
kW

###
569

82.8432

###

800

###
296

182.2007

###

359.599

1438.396

130

359.599

46747.87

20

260.2415

5204.83

13

260.2415

###

87

260.2415

###

260.2415

###

260.2415 260.2415

504

###

###

500

###

###

370

###

82459.7

350

###

77254.87

337

###

###

250

###

51230.72

243

###

###

242

###

###
165

260.2415

###

35

177.3983

###

17

0.0

0.0

77

###

###

42
25

Hot Duty

###

0.0

###
0.0

Stream
mCp (kW/K)
Heat Flow (kW)
Interval

Shifted Temp
(C)
1364

1
805
2

1
2
82.8432
99.3575
107033.4144 42723.725
HOT

|
|
|

HOT

3
177.3983
81958.0146

4
59.6061
13411.3725

HOT

COLD

5
6
22.4615 28.9745
6918.142 4346.175
COLD

COLD

7
93.938
###
COLD

8
9
291.97 105317.492
63357.49 105317.492
COLD

COLD

10
137.858
###
COLD

Shifted Intervals Table


Shifted
Temperature

T(i+1)-Ti

CpHot

dHHot

kW/K

kW

1364

CpCold

dHCold

Cold Duty

kW

kW/K

kW

kW

0.0

0.0

93.938

939.38

93.938

27242.02

260.7705

1564.623

260.7705

34943.247

260.7705

2607.705

254.2575

3305.3475

160.3195

13947.7965

219.9256

1539.4792

###

105399.5596

374.0376

65456.58

374.0376

9350.94

351.5761

3515.761

351.5761

2461.0327

231715.154
559

82.8432

46309.3488

805

185405.8052
10

82.8432

828.432

290

182.2007

52838.203

182.2007

1093.2042

134

359.599

48186.266

10

260.2415

2602.415

13

260.2415

3383.1395

87

260.2415

22641.0105

260.2415

1821.6905

260.2415

260.2415

175

260.2415

45542.2625

25

177.3983

4434.9575

10

177.3983

1773.983

0.0

0.0

795

272273.4715

184577.3732

505

271334.0915

131739.1702

499

244092.0715

130645.966

365

242527.4485

82459.7

355

207584.2015

79857.285

342

204976.4965

76474.1455

255

201671.149

53833.135

248

187723.3525

52011.4445

247

186183.8733

51751.203

72

80784.3137

6208.9405

47

15327.7337

1773.983

37
30

Hot Duty

5976.7937

0.0

2461.0327
0.0

P in c h T e m p e ra tu re (C )

Varying dTmin Global

This sheet will set up a case study to report the pinch temperature and the min utility requirements for varying dTmin globa
IMPORTANT: Using this function will clear all dTcontrib information from individual streams (reverting to dTmin global for a
1. Specify dTmin global range.
Max dTmin
Min dTmin

15 C
5 C

2. Click this button to run the case and re-plot the adjacent charts.

Varying Pinch Tem


35

Run Case

30
25

Plot Data (No entry required):

20
15

Hot Pinch Cold Pinch Hot Utility Cold Utility


C
C
kW
kW
10
30
20
500

10
5

M in U tility R e q u ire d (k W )

dTmin
C

0
8

10

12

dTm

Varying Min Hot an


600
500
400
300
200
100
0
8

10

12

dTm

nts for varying dTmin global values within a specified range.


erting to dTmin global for all streams).

Varying Pinch Temperature vs dTmin

Pinch Temperature (C)


Pinch Temperature (C)
Pinch Temperature (F)
dTmin global (C)
dTmin global (C)
dTmin global (F)
10

12

14

16

18

20

dTmin global (C)

Min Utility Required (kW)


Min Utility
Required vs
(kW)
Varying Min Hot and
Cold Utilities
dTmin
Min Utility Required (MJ/h)
Min Utility Required (Mbtu(IT)/hr)

10

12

14

16

dTmin global (C)

18

20

A1. Calculation Basis and Conversions


Drop-Down Lists:
Select Input D
Heat Capacity
Heat Duty
Mass Flowrate
Mass Flowrate

Select Units
Select Units
kg/s
1 kJ/kgK
kg/h
3600 J/kgK
lb/min
132.27735731 Btu(IT)/(lb.F)
lb/h
7936.6414387 kcal(IT)/(kg.C)
US ton(short) 3.968320719
UK ton(long)/ 3.543143499
ton(metric)/h
3.6

Conversion Factors:
Heat Capacity Conversion FaHeat Duty
Select Units
Select Units
kW/K
1
kW
W/K
1000
Btu(IT)/sec
kcal(IT)/Csec
0.2388459 Btu(IT)/min
Btu(IT)/Fs 0.52656506 kcal(IT)/sec
kcal(IT)/h
hp (boiler)

1
1000
0.238845897
0.238845897

Conversion Fact Mass Flowrate


Conversion Fac
Select Units
1
kg/s
1
0.94781712
kg/h
3600
56.869027219
lb/min
132.27735731
0.238845897
lb/h
7936.6414387
859.845227859 US ton(short)/h
3.968320719
0.101941995 UK ton(long)/h
3.543143499
ton(metric)/h
3.6

Calculation Source Data

The cells below are the calculation source data, the input data supplied in sheet "INDEX" is converted to the stand
Output To Calculations
Stream ID

Supply
Target
dtmin Contrib
Temperature Temperature
C

1
2
3
4
5
6
7
8
9
10

C
1369.0
800.0
504.0
25.0
42.0
350.0
337.0
25.0
242.0
243.0

DTMIN GLOBAL

C
77.0
370.0
42.0
250.0
350.0
500.0
800.0
242.0
243.0
500.0

C
5
5
5
5
5
5
5
5
5
5

1364
795
499
30
47
355
342
30
247
248

10

77
370
42
250
350
500
800
242
243
500

Temperature Units:
C
F
K
R

Name of unit Symbol Relation to SI units Relation to C


kelvin K SI base unit T[K] = T[C] + 273.15
degree Celsius C T[C] = T[K] 273.15
degree Rankine R; Ra T[Ra] = 1.8 T[K]
degree Fahrenheit F T[F] = T[K] 1.8 459.67 T[F] = 1.8 T[C] + 32

Specific Heat Ca Conversion Enthalpy Ch Conversion Factors


Select Units
Select Units
kJ/kgK
1
kJ/kg
1
J/kgK
1000
J/kg
1000
Btu(IT)/(lb.F) 0.2388459 Btu(IT)/lb 0.42992261
kcal(IT)/(kg.C) 0.2388459 kcal(IT)/kg
0.2388459

" is converted to the standard unit set.


Heat Capacity
Flowrate
mCp
kW/K
82.8432
99.3575
177.3983
59.6061
22.4615
28.9745
93.938
291.97
105317.492
137.858

Heat Load

Stream
Type

kW
###
42723.725
###
###
6918.142
4346.175
43493.294
63357.49
###
35429.506

Supply Shift Target Shift


C

HOT
HOT
HOT
COLD
COLD
COLD
COLD
COLD
COLD
COLD

Mass
Flowrate
kg/s

Conversion

C
1364.0
795.0
499.0
30.0
47.0
355.0
342.0
30.0
247.0
248.0

72.0
365.0
37.0
255.0
355.0
505.0
805.0
247.0
248.0
505.0

62.76
36.13
36.13
57.87
8.35
8.35
36.13
60.2
60.2
60.2

1
1
1
1
1
1
1
1
1
1

Output Data Unit Set:


SI-based (kW/K)
Metric-hour based (MJ/h/K)
US / Imperial (MBtu(IT)/hr/F)

Specific
Heat
Capacity
kJ/kgK
1.32
2.75
4.91
1.03
2.69
3.47
2.6
4.85
1749.46
2.29

Conversion

1
1
1
1
1
1
1
1
1
1

Presentation Units
Temperature
C
Heat Capacity Flowrat kW/K
Heat Duty
kW
Specific Heat Capacity
Mass Flowrate
Enthalpy Change

Output Options
SI
Metric
English
Heat
Capacity
Flowrate
mCp
kW/K
MJ/h/K
MBtu(IT)/hr/F
82.8432
298.23552
43.6223489381
99.3575
357.68700
52.3182051709
177.3983
638.63388
93.4117772324
59.6061
214.58196
31.3864999546
22.4615
80.86140
11.8274449885
28.9745
104.30820
15.2569643532
93.938
338.17680
49.4644848889
291.97
1051.09200
153.7412511763
105317.492
379142.97120 55456.5297490615
137.858
496.28880
72.5912299369

Temperature Options
SI/Metric
Supply Temperature
C
1369.0
800.0
504.0
25.0
42.0
350.0
337.0
25.0
242.0
243.0

ture Options
English
Supply
Target
DTMIN
DTMIN
DTMIN
DTMIN
Target Temperature Temperatu
Temperature CONTRIB GLOBAL CONTRIB GLOBAL
re
C

F
77.0
370.0
42.0
250.0
350.0
500.0
800.0
242.0
243.0
500.0

F
2496.2
1472.0
939.2
77.0
107.6
662.0
638.6
77.0
467.6
469.4

C
170.6
698.0
107.6
482.0
662.0
932.0
1472.0
467.6
469.4
932.0

C
5
5
5
5
5
5
5
5
5
5

F
10

F
9
9
9
9
9
9
9
9
9
9

18

Input
Error
Detection
Input Meth DTMIN

Select Unit Check Unit Stream Na Data

NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL

Sup Temp Targ Temp Prim Heat

NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP

NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL

NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP

NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL
NO STREANO SUPPL

NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP
NO
SUPPLY
NO TARGET
NO PRIMARY
TEMP HEAT DATA
TEMP

Sec Heat

Non numerical entry


supply

NO SECONDARY HEAT DATA


NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA

target

dtmincontri Prim Heat Sec Heat

NO SECONDARY HEAT DATA


NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA

NO SECONDARY HEAT DATA


NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA
NO SECONDARY HEAT DATA

A2. Plot Tables


Cold Composite
Actual
Temp
C
#N/A
800
504
500
370
350
337
250
243
242
77
42
25
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Shift Cold Composite

Heat
Shift Temp
Load
kW
C
#N/A
#N/A
272273
805
244468
795
244092
505
210192
499
204976
365
201671
355
187723
342
186184
255
80784.31
248
19068.11
247
5976.794
72
0
47
#N/A
37
#N/A
30
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Heat Load
kW
#N/A
272273.47
271334.09
244092.07
242527.45
207584.2
204976.5
201671.15
187723.35
186183.87
80784.314
15327.734
5976.7937
2461.0327
0
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Hot Composite
Actual
Temp
C
1369
800
504
500
370
350
337
250
243
242
77
42
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Heat
Load
kW
231715
184577
130646
129208
82459.7
77254.9
73871.7
51230.7
49409
49148.8
6208.94
0
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Shift Hot Composite


Shift Temp
C
1364
805
795
505
499
365
355
342
255
248
247
72
47
37
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Shift Hot Composite


Heat Load
kW
231715.15
185405.81
184577.37
131739.17
130646
82459.7
79857.285
76474.146
53833.135
52011.445
51751.203
6208.9405
1773.983
0
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Grand Composite
Shift
Temp
C
1364
805
795
505
499
365
355
342
255
248
247
72
47
37
30
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Net Heat
Load
kW
40558.318
86867.666
86756.718
112352.9
111881.48
125124.5
125119.21
125197
133890.22
134172.43
29033.111
9118.7932
4202.8107
2461.0327
0
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Stream
1
mCp (KW/K)
82.84
Heat Flow (KW 107033
Hot
Interval

2
3
99.36 177.4
42724 81958
Hot
Hot

4
5
6
59.61 22.46 28.97
13411 6918 4346
Cold
Cold Cold
T(C)
1369

T ( C)
1359

810

800

800

790

510

500

504

494

370

360

360

350

347

337

260

250

253

243

252

242

77

67

52

42

42

32

35

25

1
2
3
4
5
6
7
8
9
10
11
12
13
14

7
93.94
43493
Cold

8
9
291.97 105317
63357 105317
Cold
Cold

10
137.86
35430
Cold Q (KW)
46309.35
-110.95
25596.18
-471.42
13243.02
-5.29
77.79
8693.21
282.21
-105139.3
-19914.32
-4915.98
-1741.78
-2461.03

Interval
Units

Shift
Temperature
C
1369

T interval

mCpnet

dH

kW/K

kW

559

82.8432

46309.35

10

-11.0948

-110.95

290

88.2627

25596.18

-78.5698

-471.42

134

98.8285

13243.02

10

-0.529

-5.29

13

5.984

77.79

87

99.922

8693.21

40.3159

282.21

-105139.3181

-105139.32

175

-113.7961

-19914.32

25

-196.6393

-4915.98

10

-174.1778

-1741.78

-351.5761

-2461.03

Temperature ( C)
1369
810

810
2

800

800
3

510

510
4

504

504
5

370

370
6

360

360
7

347

347
8

260

260
9

253

253
10

252

252
11

77

77
12

52

52
13

42

42
14
25

PINCH

35

Hot Utility

11525.21
31439.52
36355.51
38097.28
40588.32

Cascade

Cold Utility Temperature ( C )

46309.35

-110.95

25596.18

-471.42

13243.02

-5.29

77.79

8693.21

282.21

-105139.32

-19914.32

-4915.98

-1741.78

-2461.03

1359

46309.35

800

46198.40

790

71794.58

500

71323.17

494

84566.18

360

84560.89

350

84638.69

337

93331.90

250

93614.11

243
242
67
42
32
25

Cascade

46309.35

-110.95

25596.18

-471.42

13243.02

-5.29

77.79

8693.21

282.21

-105139.32

-19914.32

-4915.98

-1741.78

-2461.03

Final Pass
40558.32
86867.67
86756.72
112352.90
111881.48
125124.50
125119.21
125197.00
133890.22
134172.43
29033.11
9118.79
4202.81
2461.03
0

Temperature ( C)

Heat Flow (Kw) mCp ( kW/ K)

Temperature ( C )1369 800


Stream Number

107033

82.84

8547

19.88

8547

19.88

8547

19.88

8547

19.88

8547

19.88

81958

177.4

13411

59.06

6918

22.46

4346

28.97

43493

93.94

63357

291.97

105317

105317.49

35429

137.86

10

504

500

370

350 337

250

5
3
5

3
1

243

242

77

1
11

6
1

42

25
Pinch ( C)

Pinch ( C)

35

35

utility

35

35

done

35

35

8547

35

35

1613

35

35

done

35

35

done

35

35

done

25

25

done

25

25

done

25

25

done

25

25

25

25

done

25

25

25

25

4308
Utilities
1 ( Cooling)
2 ( Cooling)
3 ( Heating)
4 ( Heating)
5 ( Heating)

105317
?

Pinch Matches
1
2
3
4
5
6
7
8
9
\

Q (kW)

Q ( kW)
14500.72
18601
43493

92532.28
63357

S-ar putea să vă placă și