Determines the required water and steam flows for a required feedwater mass flow.
Deaerator Pressure *
psig
Vent Rate *
klb/hr
Water
Pressure*
psig
Steam
Pressure*
psig
* Required
Examples:
Mouse Over
Calculation Details
Step 4: Determine Feedwater and Vented Mass Flows and Total Outlet Energy Flows
Vented Steam Mass Flow = Vent Rate * Feedwater Mass Flow
Total DA Mass Flow = Vented Steam Mass Flow + Feedwater Mass Flow
Total Outlet Energy Flow = [Feedwater Specific Enthalpy * Feedwater Mass Flow] +
[Vented Steam Specific Enthalpy * Vented Steam Mass Flow]
Assumptions
The Deaerator (DA) Vent Rate is a percent of feedwater flow.
The feedwater leaves the DA as a saturated liquid at DA pressure.
The DA vented gases are assumed to be saturated gas at DA pressure.
The DA has no additional heat or masses losses.