Documente Academic
Documente Profesional
Documente Cultură
Pleasant
Library
3160 16th Street, NW
Washington, DC 20010
901 G Street, NW
Washington, DC 20001
Architect
REV DT ISSUED
5-29-09 SCHEMATIC DESIGN
SECOND FLOOR
50 PAIR COPPER
6 STRANDS MM / 6 STRANDS SM
FIRST FLOOR
DATA RM CAT 6 UTP RG-6
SEE OUTLET DETAIL
100PR CAT 3 I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
eC
Elec.
008 eB
901 G Street, NW
W
Washington, DC 20001
Mech.
007 Architect
F
eA
W Elev.
E 009
Mop W
D Sink
Women's Men's 4/0
011 010 Garden
F 1010 wisconsin avenue, nw
and Entry suite 405
Storage washington, dc 20007
C.5 Trash
014
T 202.466.6116
006
F 202.466.6235
Conf.
C 012
B
Hallway Lobby
005 013 3 East 28th Street, 6th Floor
New York, NY 10016
A.7
Stair T 212.696.0414
004
A Structural Engineer
ReStl Designers, Inc.
1001 Connecticut Ave, NW, Suite 320
eF Washington, DC 20036
Stair
003 Info T 202.452.1103
016 Adult Non-Fiction F 202.452.1133
015
MEP Engineer
2/0 4/0
F F
W
7061 Deepage Drive
Mech. Columbia, MD 21045
002
4/0 4/0 T 410.381.7100
eE F F F 410.381.7110
Stacks
017 Civil Engineer
AMT
12750 Twinbrook Parkway
Rockville, MD 20852
4/0
Study F T 301.881.2545
eD 021 F 301.881.0814
Young Adult 4/0
001 Landscape Architect
F 1/1
1/1 Study
eE.5 1/1 2410 17th Street, NW, Suite 201
4/0 018
Washington, DC 20009
Study
022 F
Comp./
eC Conf. T 202.588.5454
020 F 202.588.5449
e10
4/0
eB Pump
REV DT ISSUED
F Room 5-29-09 SCHEMATIC DESIGN
019 7-17-09 DESIGN DEVELOPMENT
Study
1/1 Study
024 023 12-4-09 ISSUED FOR PERMIT
1/1
e9
eA
e8
e7
eC.1
e1 e2 e3 e4
eE
eD
901 G Street, NW
Washington, DC 20001
G
1/1 1/1 Architect
eC
Storage
107 eB
4/0 T 301.881.2545
F 301.881.0814
eE F Landscape Architect
Display
116 2410 17th Street, NW, Suite 201
SELF CHECK OUT POINT Washington, DC 20009
4/0 4/0 4/0
F T 202.588.5454
eD 4/0 F F F 202.588.5449
Stacks F
102
DP REV DT ISSUED
eE.5 Entry
5-29-09 SCHEMATIC DESIGN
Vestibule 7-17-09 DESIGN DEVELOPMENT
117
12-4-09 ISSUED FOR PERMIT
eC
e10
4/0
eB 4/0 F 1/1 CR
DP
Exit
Vestibule F DOWN
101 CR
1/1 DOWN
PORCH PEDESTAL MOUNTED CARD e9
READERS FOR HANDICAPPED
eA ACCESS
e8
DRAWING NOTES: #
e6
e5.8
e5.7
e5.3 First Floor Plan
e5.2
e5 - Telecom
e1 e2 e3 e4
1' 0 4' 8' 12' 16'
N T1.02
Printed: 11/11/08
© core group, pc 2008
GRAPHIC SCALE 1/8" = 1'-0"
ASE JOB# 0811_179
eF
1 2 2.3 3 3.9 4 5 5.7 6
Mt. Pleasant
DRAWING NOTES: #
Library
eE 3160 16th Street, NW
1. 8' HIGH x 4' LONG x 3/4" THICK, A/C GRADE OR BETTER , Washington, DC 20010
VOID-FREE PLYWOOD AND EITHER FIRE RATED OR
TREATED ON ALL SIDES WITH AT LEAST TWO COATS OF
EDGE OF
CANOPY FIRE-RESISTANT LIGHT COLORED PAINT. TO REDUCE
BELOW eD WARPING PLYWOOD SHOULD BE KILN-DRIED TO MAXIMUM
MOISTURE CONTENT OF 15%.
G Staff
Bathroom 1/0 1/0 1/0
208
Workroom eC 901 G Street, NW
207 Washington, DC 20001
Elevator eB Architect
Staff Lounge
Control Closet 210
206
F Roof
Access eA
205 Elev.
E 209
1010 wisconsin avenue, nw
suite 405
D washington, dc 20007
Branch 1/0 Elec.
Friends of T 202.466.6116
Manager 213
the Library F 202.466.6235
204 211
C.5 Strollers
1/0
203
C 1 Bathroom
215
3 East 28th Street, 6th Floor
B New York, NY 10016
Bridge Open
212 below SWING RACK
Storage
T 212.696.0414
DOWN
220 Structural Engineer
A.7
DOWN ReStl Designers, Inc.
1001 Connecticut Ave, NW, Suite 320
A Workroom
Washington, DC 20036
Open 214 T 202.452.1103
below F 202.452.1133
eF
2/1 MEP Engineer
Stair F Info
202
216 Children's
Program
217 7061 Deepage Drive
4/0 Columbia, MD 21045
Ship's Ladder RAMP
F UP T 410.381.7100
to Attic Reading F 410.381.7110
218
DOWN
Civil Engineer
AMT
eE 12750 Twinbrook Parkway
ED
UP
D
Rockville, MD 20852
SI
LE
G
N
SI
T 301.881.2545
4/0 F 301.881.0814
4/0 Young
ED
Landscape Architect
D
SI
F Children
LE
4/0
G
N
eD F
SI
SINGLE SIDED
219 U
P
F 2410 17th Street, NW, Suite 201
4/0 Washington, DC 20009
F T 202.588.5454
eE.5 4/0 F 202.588.5449
UP
4/0
F SINGLE SIDED
eC F
Children's REV DT ISSUED
Stacks e10 5-29-09 SCHEMATIC DESIGN
201
7-17-09 DESIGN DEVELOPMENT
eB 4/0 4/0
UP
12-4-09 ISSUED FOR PERMIT
F F
e9
eA
Alcove
221
e8
Alcove
220
e7
eC.1
e5.2
e5
(TYPICAL) J, JB JUNCTION BOX MECHANICAL, AND ELECTRICAL SYSTEMS, AND BE FAMILIAR WITH ALL
N/A NOT APPLICABLE CONDITIONS, NEW OR EXISTING, WHICH AFFECT THE INSTALLATION. 901 G Street, NW
NIC NOT IN CONTRACT
C
PR PAIR
TELECOMMUNICATIONS SYSTEM INSTALLATION MATRIX FOR ANY CONDITIONS WHICH AFFECT THE WORK. EQUIPMENT LOCATIONS ARE
FLOOR DESCRIPTION ELECTRICAL COMMUNICATIONS OWNER / USER COMMENTS APPROXIMATE AND SHALL BE FIELD VERIFIED.
RM ROOM
SLE SLEEVE CONTRACTOR CONTRACTOR GROUP 5. ALL WORK SHALL BE INSTALLED IN A NEAT AND GOOD WORKMANSHIP MANNER.
5 COMBINATION OUTLET UG UNDERGROUND
COMMUNICATIONS RACEWAYS FURNISH & INSTALL RING & STRING, BOX & CONDUIT, SLEEVES, CONDUIT, ETC.
T0.01 SCALE: NONE J-HOOKS FURNISH & INSTALL 6. ALL WORK SHALL BE CONCEALED BEHIND BUILDING FINISHES TO THE
UNO UNLESS NOTED OTHERWISE
CABLE TRAYS FURNISH & INSTALL GREATEST DEGREE POSSIBLE. WHERE CONCEALED, LOW VOLTAGE CIRCUITS
TYPICAL OF LOCATIONS WITH SYMBOL W/ WITH MAY RUN USING PLENUM RATED CABLE. WHERE EXPOSED, THE APPROPRIATE 1010 wisconsin avenue, nw
COMMUNICATIONS FIRESTOPPING FURNISH & INSTALL suite 405
INDICATES FLOOR BOX, RACEWAY SHALL BE USED.
COMMUNICATIONS CABLING FURNISH & INSTALL VOICE / DATA / AV HORIZONTAL CHANNEL & BACKBONE, ETC. washington, dc 20007
COORDINATE WITH ARCHITECT
INDICATES OVERHEAD LOCATION COMMUNICATIONS TERMINATION EQUIPMENT FURNISH & INSTALL RACKS, PATCH PANELS, PUNCH BLOCKS, ETC. 7. UNLESS OTHERWISE NOTED, CARD READERS (PROXIMITY) CONTROL ADJACENT T 202.466.6116
DATA NETWORK EQUIPMENT FURNISH, INSTALL & CONFIGURE ACTIVE EQUIPMENT DOOR VIA AN ELECTRIC LOCKSETS OPERATION (MORTISE OR STRIKE). REFER F 202.466.6235
VOICE NETWORK EQUIPMENT FURNISH, INSTALL & CONFIGURE ACTIVE EQUIPMENT TO THE SECURITY DOOR SCHEDULE.
VOICE PHONE SETS FURNISH, INSTALL & CONFIGURE
(2) CAT 6 PLENUM CABLES CABLE TO LOCAL 8. ELECTRIC LOCKSETS OPERATION (MORTISE OR STRIKE), MAGNETIC LATCHES,
TO TELEPHONE ROOM CONTROL & POWER TELECOM GROUNDING SYSTEM FURNISH & INSTALL
AND DOOR CONTACTS TO BE PROVIDED BY DOOR / HARDWARE VENDOR.
SUPPLY LOCATION OUTSIDE PLAN - CABLING FURNISH & INSTALL
COORDINATE EQUIPMENT SELECTION AS REQUIRED.
OUTSIDE PLANT - RACEWAYS FURNISH & INSTALL INSTALL TO PROPERTY LINE; CO ORD. W/ SERVICE PROVIDER 3 East 28th Street, 6th Floor
DOOR POSITION SWITCH BY
DOOR VENDOR- WIRING BY JUNCTION BOX IN 9. COORDINATE THE LOCATION OF SYSTEM SUPPORT EQUIPMENT (SERVERS, New York, NY 10016
SECURITY VENDOR CONCEALED BUT RECORDING EQUIPMENT) AND POWER SUPPLIES WITH THE OWNER.
CEILING FACEPLATE ACCESSIBLE T 212.696.0414
DESIGNATION LOCATION 10. THESE DRAWINGS MUST CONSIDERED AS PART OF AN ENTIRE DOCUMENT SET Structural Engineer
1" CONDUIT TO LABEL
DESIGN DEVELOPMENT
A
RJ-45 JACK 11. PROVIDE DEVICE BOX OR BACK BOX AS REQUIRED BY DEVICE OR COMPONENT
DECEMBER 12-19-08
T 202.452.1103
3/20/09 - 100% CD
(TYPICAL) MANUFACTURER TO SUPPORT EACH DEVICE SHOWN OR REQUIRED.
B
NOTES: F 202.452.1133
1. FROM SECURE SIDE CARD READER TELECOMMUNICATION DRAWING INDEX 12. ALL RACEWAYS AND BOXES SHALL BE INSTALLED IN COMPLIANCE WITH MEP Engineer
18" AFF 2. ADJUST DEVICE REQUIREMENTS SET FORTH IN DIVISION 16 SPECIFICATION SECTIONS
LOCATIONS PER PLAN CR DRAWING NO. DRAWING TITLE
13. ALL ELECTRICALLY HELD DEVICES IN EGRESS PATHWAYS SHALL FAIL TO
FLOOR TO.01 DATA SHEET - TELECOM A CONDITION THAT ALLOWS EGRESS UPON LOSS OF POWER OR UPON 7061 Deepage Drive
ELECTRIC STRIKE BY ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM. ACCESS CONTROL THROUGH Columbia, MD 21045
DOOR HARDWARE T1.01 TERRACE FLOOR PLAN - TELECOM
NON-EGRESS DOORWAYS AND DETENTION DOORS SHALL BE MAINTAINED AT ALL
VENDOR - WIRING T1.02 FIRST FLOOR PLAN - TELECOM T 410.381.7100
BY SECURITY VENDOR TIMES.
T1.03 SECOND FLOOR PLAN - TELECOM
3 DATA OUTLET T2.01 RISER SHEET - TELECOM
F 410.381.7110
T0.01 SCALE: NONE ELECTRONIC SECURITY LEGEND Civil Engineer
AMT
TYPICAL OF LOCATIONS WITH SYMBOL 8 ELECTRIC STRIKE/POSITION SWITCH/CARD 12750 Twinbrook Parkway
INDICATES FLOOR BOX T0.01 READER DOOR DETAIL SYMBOL DESCRIPTION Rockville, MD 20852
INDICATES OVERHEAD LOCATION SCALE: NONE CARD READER: MOUNT 48" AFF UNO. WHERE INDICATED DOOR INCLUDES POSITION T 301.881.2545
CR
SWITCH & ELEC. STRIKE/LATCH UNO. F 301.881.0814
(2) CAT 6 CABLES ELECTRIC STRIKE/LATCH. SEE DOOR SCHEDULE FOR DEVICE TYPE Landscape Architect
TO TELEPHONE ROOM CABLE TO LOCAL EL
CONTROL & POWER
SUPPLY LOCATION KEYPAD. 2410 17th Street, NW, Suite 201
K Washington, DC 20009
JUNCTION BOX IN CONCEALED 12" T 202.588.5454
CEILING BUT ACCESSIBLE LOCATION DP
DOOR POSITION SWITCH. F 202.588.5449
WALL OUTLET FRAME ON SECURED SIDE OF DOOR
1" CONDUIT TO (STAINLESS STEEL)
ACCESSIBLE DOOR POSITION SWITCH CONTROL PANEL.
CEILING SPACE BY DOOR VENDOR WIRED CTR REV DT ISSUED
CABLE DESIGNATION
DETAIL (TYPICAL) WIRED HINGE BY DOOR BY ESC (TYPICAL OF 2) 5-29-09 SCHEMATIC DESIGN
VENDER, WIRING BY ESC REMOTE DOOR RELEASE.
SINGLE RJ-45 WALL- RR 7-17-09 DESIGN DEVELOPMENT
PHONE OUTLET 12-4-09 ISSUED FOR PERMIT
CARD READER BY ESC INTERCOM STATION.
54" AFF I
CR
HC HC FIXED CAMERA.
FLOOR
PTZ PAN-TILT-ZOOM CAMERA.
HANDICAP OPERATOR BUTTON
AND WIRING BY DOOR VENDOR
NOTES:
2 WALL PHONE OUTLET 1. FROM SECURE SIDE. INTERLOCKED DOORS.
T0.01 SCALE: NONE 2. ADJUST DEVICE LOCATIONS PER PLAN.
W REQUEST TO EXIT SENSOR.
TYPICAL OF LOCATIONS WITH SYMBOL 7 DOOR POSITION/HANDICAP OPERATION/CARD READER REX
T0.01 SCALE: NONE
MOTION SENSOR
M
CABLE TO LOCAL
CONTROL & POWER
SUPPLY LOCATION COMMUNICATIONS LEGEND
SYMBOL DESCRIPTION
TELECOMMUNICATION OUTLET-WALL, FLOOR, CEILING: PROVIDE DOUBLE GANG
DOOR POSITION SWITCH
BY DOOR VENDOR WIRED BOX WITH PLASTER RING AND A 1"C WITH PULL WIRE TO NEAREST BASKET
BY ESC (TYPICAL OF 2) TRAY. PROVIDED CABLE TYPE AND QUANTITY AS INDICATED ON PLAN
2/1 F C DRAWING(S). MOUNT 18" AFF UNO. #/# FIRST NUMBER IDENTIFIES QUANTITY OF I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
JUNCTION BOX IN CONCEALED DATA CABLES SECOND NUMBER IDENTIFIES QUANTITY OF VOICE CABLES. DULY LICENSED ARCHITECT UNDER THE LAWS OF
BUT ACCESSIBLE LOCATION DISTRICT OF COLUMBIA
NOTE: ON SECURED SIDE OF DOOR WALL HANGER VOICE OUTLET: PROVIDE DOUBLE GANG BOX WITH PLASTER
SOLID COPPER GROUNDING BUSBARS SHALL BE INSTALLED WITH INSULATED W RING AND A 1"C WITH PULL WIRE TO NEAREST BASKET TRAY. CABLE PROVIDED
STANDOFFS AND SHALL BE A MINIMUM OF 1/4" THICK X 4" HIGH X 10" LONG.
EACH BUSBAR SHALL BE DRILLED WITH ROWS OF HOLES ACCORDING TO BY OTHERS UNDER SEPARATE CONTRACT. MOUNT 48" UNO.
NEMA STANDARDS, FOR ATTACHMENT OF BOLTED COMPRESSION FITTINGS. Project No. 08002.10
PROVIDE SINGLE GANG BOX FOR CABLE TELEVISION OUTLET. 1" C WITH PULL
NOTES: WIRE FROM JUNCTION BOX LOCATION TO NEAREST BASKET TRAY. MOUNT 18"
1. FROM SECURE SIDE. TV AFF UNLESS OTHERWISE NOTED.
1 GROUNDING BUSBAR DETAIL 2. ADJUST DEVICE LOCATIONS PER PLAN. Data Sheet
T0.01 SCALE: NONE TELECOMMUNICATIONS FURNITURE FEED. - Telecom
6 MORTISE LOCK - MANUAL OPERATION W/ DOOR POSITION SWITCH
T0.01
CC
T0.01 SCALE: NONE