Sunteți pe pagina 1din 5

3400

250
200

1
6
6

3400
1500
1200
6100

1768.11594

CARGAS A ALIMENTAR
S-E

CIRCUITO
N

C-1
C-2
C-3
C-4
C-5

TOTAL

(
(
(
(

1
2
3
4

)
)
)
)

=
=
=
=

Servicio Particular (F.S.=


0,5)
N Lotes
Vivienda

N Lotes
Vivienda
Taller

Cargas
especiales
(KW)
(F.S.=1,0)

36
35
36
25
34
166

(
(
(
(

800W / lote ) (N Lotes Vivienda ) ( FS)


Carga / lote ) (N Lotes Vivienda - Taller ) ( FS)
Carga Kw ) ( FS )
N lamp. De 50 W x 0,060 KW/Lamp. + N Lamp. De 70 W x 0,0

952893489

A ALIMENTAR

DEMANDA PROYECTADA (KW)

Alumbrado Pblico
( F.S. = 1,0)
Vivienda
N Lamparas N Lamparas
(1)
de 50 W.
de 70 W.
( 60 W. )
( 81 W. )
15
15
15
15
15
75

14.40
14.00
14.40
10.00
13.60
0.00
66.40

Lamp. De 70 W x 0,081 KW/Lamp. ) (FS)

Vivienda
Taller
(2)
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Mxima
Demanda
Cargas Alumbrado
Proyectada
especiales Pblico
(KW)
(3)
(4)
0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.90
0.90
0.90
0.90
0.90
0.00
4.50

15.30
14.90
15.30
10.90
14.50
0.00
70.90

Capcidad
del Transf.
(KVA)

S-ar putea să vă placă și