Sunteți pe pagina 1din 8

Checking network for errors:

No errors were found


Initializing database DLL
Renumbering branches and links
Locating system outfalls...please wait
Node OUT FALL is an outflow
Creating subnetwork 1 upstream of node OUT FALL
Finding start nodes in subnetwork 1
Start node MH 38
Start node MH 30
Start node MH 10
Start node MH 25
Start node MH 15
Start node MH 18
Start node MH 39
Start node MH 19
Start node MH 21
Start node MH 41
Start node MH 26
Start node MH 34
Start node MH 43
Start node MH 36
Start node MH 31
Start node MH 35
Start node MH 37
Start node MH 40
Start node MH 42
Numbering branches and links in subnetwork 1
Start node MH 10
MH 10 Subnet 1 Branch 1 Link 1
MH 11 Subnet 1 Branch 1 Link 2
MH 12 Subnet 1 Branch 1 Link 3
MH 13 Subnet 1 Branch 1 Link 4
MH 14 Subnet 1 Branch 1 Link 5
MH 6 Subnet 1 Branch 1 Link 6
OUT FALL Subnet 1 Branch 1 Link 7
Start node MH 15
MH 15 Subnet 1 Branch 2 Link 1
MH 16 Subnet 1 Branch 2 Link 2
MH 17 Subnet 1 Branch 2 Link 3
Start node MH 18
MH 18 Subnet 1 Branch 3 Link 1
Start node MH 19
MH 19 Subnet 1 Branch 4 Link 1
MH 20 Subnet 1 Branch 4 Link 2
Start node MH 21
MH 21 Subnet 1 Branch 5 Link 1
MH 23 Subnet 1 Branch 5 Link 2
MH 22 Subnet 1 Branch 5 Link 3
Start node MH 25
MH 25 Subnet 1 Branch 6 Link 1
Start node MH 26
MH 26 Subnet 1 Branch 7 Link 1
MH 27 Subnet 1 Branch 7 Link 2
Start node MH 30
MH 30 Subnet 1 Branch 8 Link 1
Start node MH 31
MH 31 Subnet 1 Branch 9 Link 1
MH 32 Subnet 1 Branch 9 Link 2
MH 33 Subnet 1 Branch 9 Link 3

MH 29 Subnet 1 Branch 9 Link 4


Start node MH 34
MH 34 Subnet 1 Branch 10 Link 1
MH 28 Subnet 1 Branch 10 Link 2
Start node MH 35
MH 35 Subnet 1 Branch 11 Link 1
Start node MH 36
MH 36 Subnet 1 Branch 12 Link 1
Start node MH 37
MH 37 Subnet 1 Branch 13 Link 1
MH 7 Subnet 1 Branch 13 Link 2
MH 8 Subnet 1 Branch 13 Link 3
MH 9 Subnet 1 Branch 13 Link 4
MH 5 Subnet 1 Branch 13 Link 5
Start node MH 38
MH 38 Subnet 1 Branch 14 Link 1
MH 1 Subnet 1 Branch 14 Link 2
MH 2 Subnet 1 Branch 14 Link 3
MH 3 Subnet 1 Branch 14 Link 4
MH 4 Subnet 1 Branch 14 Link 5
Start node MH 39
MH 39 Subnet 1 Branch 15 Link 1
Start node MH 40
MH 40 Subnet 1 Branch 16 Link 1
Start node MH 41
MH 41 Subnet 1 Branch 17 Link 1
MH 24 Subnet 1 Branch 17 Link 2
Start node MH 42
MH 42 Subnet 1 Branch 18 Link 1
Start node MH 43
MH 43 Subnet 1 Branch 19 Link 1
1 outfall(s) located
Calculating link lengths
Length MH 1
Length MH 10
Length MH 11
Length MH 12
Length MH 13
Length MH 14
Length MH 15
Length MH 16
Length MH 17
Length MH 18
Length MH 19
Length MH 2
Length MH 20
Length MH 21
Length MH 22
Length MH 23
Length MH 24
Length MH 25
Length MH 26
Length MH 27
Length MH 28
Length MH 29
Length MH 3
Length MH 30
Length MH 31
Length MH 32
Length MH 33

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

48.970
39.441
47.056
36.335
24.048
83.957
64.819
26.276
84.818
36.990
19.325
35.690
45.274
38.010
22.069
26.493
36.321
37.804
24.552
35.894
26.475
46.944
67.088
38.161
38.796
25.707
42.887

Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length
Length

MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH

34
35
36
37
38
39
4
40
41
42
43
5
6
7
8
9

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

40.548
42.635
38.521
39.129
42.587
39.608
54.874
37.064
44.292
37.472
39.662
42.664
65.056
47.499
36.503
95.003

Reset calculated values


Tracing outfalls in subnetwork 1...please wait
Tracing outfall to node MH 11
Tracing outfall to node MH 12
Tracing outfall to node MH 13
Tracing outfall to node MH 14
Tracing outfall to node MH 6
Tracing outfall to node OUT FALL
Designing Node MH 10
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.033
0.000
0.000
0
0 1
Designing Node MH 30
Inflow = 0.087
Cover Level Fixed Invert
174.003
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 11
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
173.595
0.000
0.000
Adjusting incoming link MH 30
Adjusting incoming link MH 10

Fixed Size No
0
0 1

Designing Node MH 25
Inflow = 0.087
Cover Level Fixed Invert
174.344
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 12
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
173.779
0.000
0.000
0
0 1
Adjusting incoming link MH 25
Adjusting incoming link MH 11
Inverts Common: Adjusting MH 12 inlevel from 172.222 to 171.803
Adjusting incoming link MH 25
Inverts Common: Adjusting MH 25 outlevel from 172.222 to 171.803
Adjusting incoming link MH 11
Designing Node MH 13
Inflow = 0.108

Cover Level Fixed Invert Fixed Slope Fixed Size No


173.436
0.000
0.000
0
0 1
Adjusting incoming link MH 12
Inverts Common: Adjusting MH 13 inlevel from 171.879 to 171.621
Adjusting incoming link MH 12
Designing Node MH 14
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
172.964
0.000
0.000
Adjusting incoming link MH 13

Fixed Size No
0
0 1

Designing Node MH 15
Inflow = 0.108
Cover Level Fixed Invert
173.034
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 21
Inflow = 0.087
Cover Level Fixed Invert
173.450
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 41
Inflow = 0.043
Cover Level Fixed Invert
174.052
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 24
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.405
0.000
0.000
0
0 1
Adjusting incoming link MH 41
Inverts Common: Adjusting MH 24 inlevel from 172.848 to 172.274
Adjusting incoming link MH 41
Designing Node MH 23
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
173.340
0.000
0.000
0
0 1
Adjusting incoming link MH 24
Adjusting incoming link MH 21
Inverts Common: Adjusting MH 23 inlevel from 171.783 to 171.703
Adjusting incoming link MH 24
Inverts Common: Adjusting MH 24 outlevel from 171.783 to 171.703
Adjusting incoming link MH 21
Designing Node MH 26
Inflow = 0.087
Cover Level Fixed Invert
174.467
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 31
Inflow = 0.022
Cover Level Fixed Invert
174.080
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 36
Inflow = 0.022
Cover Level Fixed Invert
174.851
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 32
Inflow = 0.022
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.054
0.000
0.000
0
0 1
Adjusting incoming link MH 36
Adjusting incoming link MH 31
Inverts Common: Adjusting MH 32 inlevel from 172.497 to 172.329
Adjusting incoming link MH 36
Inverts Common: Adjusting MH 36 outlevel from 172.497 to 172.329
Adjusting incoming link MH 31
Designing Node MH 35
Inflow = 0.022
Cover Level Fixed Invert
175.010
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 33
Inflow = 0.022
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.203
0.000
0.000
0
0 1
Adjusting incoming link MH 35
Adjusting incoming link MH 32
Inverts Common: Adjusting MH 33 inlevel from 172.646 to 172.200
Adjusting incoming link MH 35
Inverts Common: Adjusting MH 35 outlevel from 172.646 to 172.200
Adjusting incoming link MH 32
Designing Node MH 34
Inflow = 0.022
Cover Level Fixed Invert
174.009
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 28
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.039
0.000
0.000
0
0 1
Adjusting incoming link MH 34
Inverts Common: Adjusting MH 28 inlevel from 172.482 to 172.249
Adjusting incoming link MH 34
Designing Node MH 29
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.788
0.000
0.000
0
0 1
Adjusting incoming link MH 33
Inverts Common: Adjusting MH 29 inlevel from 173.231 to 171.986
Adjusting incoming link MH 33
Adjusting incoming link MH 28
Inverts Common: Adjusting MH 28 outlevel from 172.117 to 171.986
Designing Node MH 27
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
174.640
0.000
0.000
0
0 1
Adjusting incoming link MH 29
Inverts Common: Adjusting MH 27 inlevel from 173.083 to 171.751
Adjusting incoming link MH 29
Adjusting incoming link MH 26
Inverts Common: Adjusting MH 26 outlevel from 172.787 to 171.751

Designing Node MH 22
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope Fixed Size No
173.204
0.000
0.000
0
0 1
Adjusting incoming link MH 27
Inverts Common: Adjusting MH 22 inlevel from 171.647 to 171.572
Adjusting incoming link MH 27
Adjusting incoming link MH 23
Inverts Common: Adjusting MH 22 inlevel from 171.572 to 171.571
Adjusting incoming link MH 27
Inverts Common: Adjusting MH 27 outlevel from 171.572 to 171.571
Adjusting incoming link MH 23
Designing Node MH 16
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
172.561
0.000
0.000
Adjusting incoming link MH 22
Adjusting incoming link MH 15
Designing Node MH 18
Inflow = 0.087
Cover Level Fixed Invert
172.140
0.000

Fixed Size No
0
0 1

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 17
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
171.914
0.000
0.000
Adjusting incoming link MH 18
Adjusting incoming link MH 16

Fixed Size No
0
0 1

Designing Node MH 19
Inflow = 0.087
Cover Level Fixed Invert
172.101
0.000

Fixed Slope
0.000

Designing Node MH 20
Inflow = 0.087
Cover Level Fixed Invert Fixed Slope
171.654
0.000
0.000
Adjusting incoming link MH 19
Designing Node MH 37
Inflow = 0.022
Cover Level Fixed Invert
173.598
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Fixed Size No
0
0 1

Fixed Size No
0
0 1

Designing Node MH 7
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
173.640
0.000
0.000
0
0 1
Adjusting incoming link MH 37
Inverts Common: Adjusting MH 7 inlevel from 172.083 to 171.845
Adjusting incoming link MH 37
Designing Node MH 40
Inflow = 0.022
Cover Level Fixed Invert

Fixed Slope

Fixed Size No

173.773

0.000

0.000

Designing Node MH 8
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
173.564
0.000
0.000
0
0 1
Adjusting incoming link MH 40
Adjusting incoming link MH 7
Inverts Common: Adjusting MH 8 inlevel from 172.007 to 171.608
Adjusting incoming link MH 40
Inverts Common: Adjusting MH 40 outlevel from 172.007 to 171.608
Adjusting incoming link MH 7
Designing Node MH 42
Inflow = 0.043
Cover Level Fixed Invert
173.436
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 9
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
172.991
0.000
0.000
0
0 1
Adjusting incoming link MH 42
Adjusting incoming link MH 8
Inverts Common: Adjusting MH 9 inlevel from 171.434 to 171.425
Adjusting incoming link MH 42
Inverts Common: Adjusting MH 42 outlevel from 171.434 to 171.425
Adjusting incoming link MH 8
Designing Node MH 38
Inflow = 0.022
Cover Level Fixed Invert
173.646
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 1
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
173.333
0.000
0.000
Adjusting incoming link MH 38

Fixed Size No
0
0 1

Designing Node MH 39
Inflow = 0.022
Cover Level Fixed Invert
173.519
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 2
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
172.873
0.000
0.000
Adjusting incoming link MH 39
Adjusting incoming link MH 1

Fixed Size No
0
0 1

Designing Node MH 43
Inflow = 0.043
Cover Level Fixed Invert
172.972
0.000

Fixed Slope
0.000

Fixed Size No
0
0 1

Designing Node MH 3
Inflow = 0.108
Cover Level Fixed Invert

Fixed Slope

Fixed Size No

172.481
0.000
Adjusting incoming link MH 43
Adjusting incoming link MH 2

0.000

Designing Node MH 4
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope
170.934
0.000
0.000
Adjusting incoming link MH 3

Fixed Size No
0
0 1

Designing Node MH 5
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
170.735
0.000
0.000
0
0 1
Adjusting incoming link MH 9
Adjusting incoming link MH 4
Inverts Common: Adjusting MH 5 inlevel from 169.178 to 169.103
Adjusting incoming link MH 9
Inverts Common: Adjusting MH 9 outlevel from 169.178 to 169.103
Adjusting incoming link MH 4
Designing Node MH 6
Inflow = 0.108
Cover Level Fixed Invert Fixed Slope Fixed Size No
170.809
0.000
0.000
0
0 1
Adjusting incoming link MH 20
Adjusting incoming link MH 17
Adjusting incoming link MH 14
Adjusting incoming link MH 5
Inverts Common: Adjusting MH 6 inlevel from 169.252 to 168.890
Adjusting incoming link MH 20
Inverts Common: Adjusting MH 20 outlevel from 169.252 to 168.890
Adjusting incoming link MH 17
Inverts Common: Adjusting MH 17 outlevel from 169.252 to 168.890
Adjusting incoming link MH 14
Inverts Common: Adjusting MH 14 outlevel from 169.252 to 168.890
Adjusting incoming link MH 5
Designing Node OUT FALL
Inflow = 0.000
Cover Level Fixed Invert Fixed Slope
169.565
0.000
0.000
Adjusting incoming link MH 6

Fixed Size No
0
0 1