Sunteți pe pagina 1din 1

What is the maximum tensile stress used for designing a small

AST acording to Appendix A if API 650?


21,000psi
(A3.1)

What joint efficiency is used for designing a small AST acording


to Appendix A of API 650?
E=0.85
E=0.70 when spot radiography is not used
(A3.4)

What is the required nominal thickness of deck plates of


external floating roofs, unless otherwise specified by the
purchaser?
3/16"
(C3.3.2)

What is the minimum nominal diameter of a roof manhole on an


AST's external floating roof?
24"
(C3.11)