Sunteți pe pagina 1din 2

represented by:

measurIT technologies

CY/A

CY/A

Vortex valve CY
wet mounted

Flexible solution
• A suitable CY controller can be found
H
for any design flow between 8-10 l/s and
[m]
H (m)
600 l/s, please see diagram to the right. 6

• Available in wet mounted and dry 4

mounted versions. (Dry mounted - 3

2
please see fact sheet CY/DK-CY/DX- 1

CY/DV) 0
1 10 100 1000

• Available with fixed (type CY/C) or


Q (l/s)
Q [l/s]
adjustable (type CY/A) inlet opening.
• The latter makes it possible to change Application chart
inflow as needed with a range of at least
+/-25% relative to its medium capacity.
• Applicable for all common types of
sewage. inlet WL

Effective control H

• Ensures close to constant discharge, inlet outlet


Qdes, virtually regardless of upstream Q
head, H. This is illustrated by the head-
discharge curve sketch overleaf.
Definition sketch (CY/A)

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
represented by:

measurIT technologies

Low maintenance/operating
costs H
[m] (Qdes,Hdes)
• Large passageway
• Horizontal (level) passageway
• No moving parts
• Does not require any power supplies
• Fabricated in acid-resistant stainless
steel AISI 316L (Werkstoff 1.4404)
Q [l/s]

Low construction costs Head–discharge curve for CY

• Can be fitted in existing or designed The vortex valve with


manholes or tanks - a separate housing adjustable inlet is our best
structure is mostly not required. selling and most generally
• Inexpensive applicable model.

Wet mounted: The


Typical applications controller is submerged in
• At the outlet from detention basins normal operation conditions
and no separate chamber is
• In overflow/surcharce structures required.
• Temporary storage in upstream sewer Dry mounted: The
system controller is placed in a
• Limits discharge to hydraulic capacity of separate chamber and the
downstream sewage system flow enters via a pressurised
pipe. Outlet to a bottom
• At inlet to pumping stations groove in the structure.
• At inlet to sand traps and treatment
plants

CY/A

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963