SWGR +RP

1
2
Version

TB

Initiation For
Check Synch

S251

kV

P1

+S1

Core-1

200/1A
-ICT

Class: 5P20
A10CT2

TB

+RP

TB

7SJ61

S511

T1

R/P

7SJ61

87NL

F871

T1

R/P

7SJ61

T1

R/P

7SJ61

T1

R/P

7PG15

86

K311

Master Trip Relay

S511

R/P

7PG17

74

K312

Trip Circuit Supervision Relay

S201

6MD664
A

VAr

TO 11kV SCS

Switch
TO BBP
PANEL

Sq.mm XLPE.,
CU Cable

T1

R/P

7PG15

63T

K342

Tx. Buchholz Trip

T1

R/P

7PG15

63P(T)

K332

Tx. Pressure Relief Trip

T1

R/P

7PG15

49OTT

K341

Tx. Oil Temperature Trip

7PG18 86BBP

K87Z1

X
X

S871

3Fs5

S871

7SJ61

3-Ph

LVAC Board

51 50BF

Note:-

* At Ambient Temperature From 40C


** At Ambient Temperature From 50C

Protection

-F871

Tx Fault Relays
63T
63P(T)
490TT
49WTT

87NL

Panel
%

Note:

Depicts shorting towards P2

Isolating link

Depicts shorting towards P1


Link.G

TS- Test Switch


TB

LV-REF

-F511

LVAC

Trip-LVAC

P2

1500/1A

-F671

Link.H

I/C -1
LV ACB
1600A

1500/1A

1-Ph

415V ACB Protection

86BBP

ONAN,Dyn11,50Hz
TB

Note:-

Oil Temp Trip-LVAC

TB- Terminal Block

For RHS T2+/- will be used for trip supply instead of T1+/-

Link.F
For A20 Bus-2 VT Shall be Connected

Link B WDG. TEMP TRIP


Wdg. Temp Trip-LVAC

400V AC Bus-1

DEVICE TYPE

% Link C OIL TEMP TRIP

DEVICE NO.

ANSI NO.

1600A, (@ 50C),3ph+Neu+PE,50Hz,50kA/1Sec,Cu. Busbar

Date 27.03.14
DTA/14/0207 04.06.14 VJS Drawn SRG
DTA/14/0508 16.12.14 SDG Appr. VJS
Remarks
Date
Name Norm
1
2

Al-Mashaaf, Khore South East, Rayyan South S/S

Orig./Repl.f./Repl.by
3

A12.RP
7SJ62

7PG18 -K87Z1

+RP

LVAC P

Tx. winding Temperature Trip

Link.E BF Initiation isolating Link (A12)

11kV Busbar

DATA COMMUNICATION

TB

7PG15 49WTT K331

7PG17 -K312

CONDUCTOR

+CC

R/P

From Busbar Panel

Link.D BF Initiation isolating Link (A18)

TO 11kV SCS

WTI CT2

T1

11kV Bus Bar Protn/BFP Trip

7PG15 -K311
86

steps of 2.5%

1500/2A,10VA

BBP2 R/P

67 67N 51 50BF

from PB

Protection Panel

P1

BBP1/ BBP

A18 RP

STRANDED CU

1500/1A
P2

+5% to -5%

7SJ62

SHEATHED

Z=5.45%

74

A10NCT1

S511

400 Sq.mm LEAD

1000kVA

110% O/C Alarm

Manual -PB
Reset

Bus-1 VT
*(Remot
synch.)

11kV 1x1Cx500

A106VT

630A

F511

BCU

Reset from BCU

DATA COMMUNICATION

CVD

Feeder O/C, E/F protection

SYNCH CHK. OK

25

MONITORING,INTERLOCK,Tx. ALARMS

A101

F511

Class: PX

CT2

OPEN/CLOSE, CONTROL,STATUS

A10CT3

CT1 Metering

50/51/
50N/51N

LV REF PROTECTION

SYNCH CHK. INITIATION

-A201

FR

S19
Synch. Sel.

1Cx500 Sq.mm

50/51/
50N/51N

DESCRIPTION

50/51 50N 51N

Core-2

2500/1A

Release Close Command

-F511

25

TO 11kV SCS

200/1A
Class: 5P20/1

Core-3

-A251

DATA COMMUNICATION

Bus Voltage

A10CT1

0.11

A166VT

7SJ64

DEVICE NO.

Line Voltage Bus

FUNCTION

CVD

A12.RP

Bus -1 Voltage Bus

TYPE

A1241

Eqpt Location

Local Synch Check

11

DC GROUP

=A16

BF Initiation in A12

BF Initiation in A18

Isolating link

CB - Q10 TRIP COIL

Link.A- CB trip
A100

LVAC CB TC

BBM1

LOCKOUT RELAY 86

ANNUNCIATION SCS/DCC

BUSBAR 1

630A
**
630A

This sheet is applicable only for Al-Mashaaf, Khore South East

11kV, 2500A, 2500A,31.5kA/3 Sec., 50Hz Busbar

P1

CopyRight (C) Siemens AG 2004 All Rights Reserved

**

STN.T1
11/0.415kV

CB CLOSE BLOCK

3/110V: 3

11kV:

P2

Symbol
Symbol
Symbol
Symbol

Project: //inggnh002ea/PTD/ANL/QAT/Ph-11/ETA_S4_DRW/Base Design/11kV Base Design_Without Hood/A10_BaseELCAD-Version


design.pro
7.7.1 SP2
library 1:
Translate file A:
Last used: 23.12.14
library 2:
Translate file B:
library 3:
Translate file C: C_FB_EN.etr, 04-04-26
library 4:
Translate file D:
Archive: = / B / AA / 5

11/0.415kV Aux. Transformer Feeder


Protection SLD & Tripping Diagram

Revision-A

Overview diagram

PH11-8A-10-35-1010
GTC/488A/2012

=A10

AA5
Sheet 5+
7 Sh.

(3)G719EA-EG9047-U5110-2
7