Documente Academic
Documente Profesional
Documente Cultură
TABLE OF CONTENTS:
SCOPE OF WORKS
PHOTOGRAPHS
PRO-01FR-36Rev.00
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia.
SCOPE OF WORKS:
1.
2.
3.
4.
5.
WELD REPAIR BOTH JOURNAL ROTOR (GEN. SIDE & GOV. SIDE)
6.
STRAIGHTENING LP ROTOR.
7.
8.
9.
PRO-01FR-100 Rev.01
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
AS RECEIVED
INSPECTION REPORT
CUSTOMER
MFG./MODEL
EQUIP./NO.
P.O. NO.
TSID PROJECT
:
:
:
:
:
PRO-01FR-44 REV.04
PRODUCTION Form
INCOMING
VISUAL INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-01
PHOTOGRAPH COMPONENT CONDITION AS RECEIVED. TAKE INDIVIDUAL PHOTOGRAPHS OF ANY AREA WHICH EXHIBITS
ABNORMAL WEAR OR DAMAGE.
RECORD ALL F.O.D., EROSION, HANDLING DAMAGE, RUST BUILD UP OR ANY OTHER OBVIOUS DEFECTS.
VISUALLY INSPECT AND RECORD GENERAL CONDITION.
MARK EACH COMPONENT WITH THE JOB NUMBER USING METAL TAGS OR AN APPROVED MARKED.
TAKE SAMPLES OF ANY DEPOSITS.
1
4
3
2
GOV SIDE
GEN SIDE
1. Coupling Gen Side exhibited medium scratches on bolt holes and axial faces, medium nick on flange, ligh
pitting, light scratch on male spigot
2. Exhibited light to medium scratches, medium pitting, medium rubs on seal area.
3. Bearing Journal Gen Side exhibited heavy rubs & pitting corrosion,deep rubs 0.5 0.28. medium rubs &
discrbration on oil deflector area, light scratch & medium pitting on probe area.
4. Gland seal Gen Side exhibited medium rubs.
5. - Stage #8 Gov & Gen side exhibited medium erosion on leading edge blades & tie wire, light to medium
pitting on disck, medium scaling.
- Stage #7 Gov & Gen side exhibited light erosion on leading edge blades, medium erosion on tie wire
- Stg #6,5,4,3,2 Gov & Gen side exhibited light pitting on blades, light rubs on shroud , medium pitting on
disk,light rubs on interstage spill strip exhibited , light rubs.
- Stg # 1 Gov & Gen side exhibited medium pitting corrosion on blades, interstage spill strip in fair conditions,
balance weight area in fair condition.
6. Gland seal Gove Side exhibited light to medium rubs.
7. Bearing Journal Gov Side exhibited heavy rubs with 0,8 deep, heavy rubs on seal area, light scratches &
pitting on probe area.
8. Coupling area Gov Side exhibted medium rubs on seal area , medium nick & dent on flange, , bolt holes
exhibited medium rubs, medium nick & dent bolt holes area, light scratches & pitting on axial face, light rubs
on male spigot.
PRO-01FR-33 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-02
AS RECEIVED
OTHERS/.
FINAL
SURFACES:
RADIAL
10
AXIAL
UNITS:
1/100 MILLIMETERS
11
2
1
1/10,000 INCHES
18
3
12
13 14 15 16
17
19
B2
A2
GOV. SIDE
GEN. SIDE
B1
A1
NOTE:
1. ALL PHASE ANGLE RECORDED : CCW AS VIEWED FROM GOV. SIDE.
2. ZERO DEGREE POINTS IS: STAMNP 1 ON DISK
3. ROTOR/SHAFT/PART IS SUPPORTED BY: LATHE MACHINE
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-56 Rev.04
Page 1 of 2
PRODUCTION Form
LP ROTOR
RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-02
INSPECTED BY: YD
STATUS:
AS RECEIVED
FINAL
SURFACES:
RADIAL
AXIAL
UNITS:
1/100 MILLIMETERS
1/10,000 INCHES
POS
10
11
12
13
14
15
16
17
18
19
A1
A2
B1
B2
45
-1
-0.5
-0.5
-0.5
-0.5
-0.5
-1
-2
-0.5
-1
0.5
0.5
-1
-0.5
-1
90
-1
-0.5
-0.5
0.5
0.5
1.5
-1
0.5
-1
-3
-2
-1
0.5
-2
-0.5
-2
135
-1
-1
-0.5
-0.5
-1
1.5
-1
0.5
-1.5
-0.5
0.5
-1
0.5
-1
180
-1
-1
-0.5
-1.5
-0.5
0.5
-0.5
-1
-0.5
-1
-0.5
-0.5
-0.5
0.5
-1
-0.5
-1
225
-0.5
-1
-1.5
-0.5
-0.5
1.5
-2
-2
3.5
-2
-1
-1
-1.5
-0.5
-1.5
270
-1
-0.5
-0.5
-1.5
-0.5
-0.5
-2
-4
-1
0.5
-1
-2
0.5
-2
315
-1
-0.5
-1.5
-0.5
-2
-1
3.5
-1
0.5
1.5
-1
-1.5
1.5
-1.5
TOTAL
0.5
0.5
-1.5
0.5
0.5
1.5
4.5
1.5
3.5
3.5
0.5
1.5
NOTE:
1. ALL PHASE ANGLE RECORDED : CCW AS VIEWED FROM "GOV SIDE".
2. ZERO DEGREE POINTS IS: STAMP N0 "1" ON DISK.
3. ROTOR/SHAFT/PART IS SUPPORTED BY: LATHE MACHINE.
APPROVED BY: ASP
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-56 Rev.04
Page 2 of 2
PRODUCTION Form
LP ROTOR
BEARING JOURNAL DIAMETER INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-03
AS RECEIVED
FINAL
1 2
SURFACES:
INSIDE DIAMETER
OUTSIDE DIAMETER
UNITS:
5 6 7
3 4
MILLIMETERS
INCHES
GOV. SIDE
GEN. SIDE
POS
379.20
379.08
379.17
379.19
379.19
379.18
379.16
379.19
90
379.19
379.09
379.15
379.19
379.19
379.17
379.16
379.18
NOTE:
1. ALL PHASE ANGLE RECORDED : 0 / 90
2. ZERO DEGREE POINTS IS: STAMP 1 ON DISK
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-55 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
GLAND SEAL DIAMETER INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-04
AS RECEIVED
FINAL
SURFACES:
INSIDE DIAMETER
OUTSIDE DIAMETER
UNITS:
MILLIMETERS
INCHES
7
8
GOV. SIDE
GEN. SIDE
POS
418.00
508.03
508.06
508.05
508.12
508.12
508.12
417.69
90
418.00
508.03
508.05
508.06
508.12
508.12
508.12
417.70
NOTE:
1. ALL PHASE ANGLE RECORDED : 0 / 90
2. ZERO DEGREE POINTS IS: STAMP 1 ON DISK
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-58 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
BEARING JOURNAL HARDNESS INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-05
AS RECEIVED
FINAL
1 2
UNITS:
5 6 7
3 4
HRC
HRB
GOV. SIDE
GEN. SIDE
NO
HARDNESS
25.9
29.9
27.5
29.1
27.5
28.8
24.5
29.2
NOTE:
1. THE PICKUP DATA SHOULD BE DIFFERENCE MAXIMUM 3 HRC BEFORE CALCULATING AVERAGE VALUE
2. TAKE ON THE SURFACE OF CLOSE RUNNING CLEARANCE
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-78 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
SURFACE ROUGHNESS INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-AR-06
AS RECEIVED
UNITS:
GEN. SIDE
- INCH
-M
GOV. SIDE
NO
SURFACE
ROUGHNESS (Ra)
0.57 ~ 0.92
0.82 ~ 1.19
0.72 ~1.08
0.80 ~ 1.01
PRO-01FR-90 Rev.04
Page 1 of 1
PRODUCTION Form
PART NO.
1 UNIT
HR
II
ITEM DESCRIPTION
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
NDT. 01 / 036M / IV 14
APRIL 12, 2014
TEST PERFORMED:
LP ROTOR
AS RECEIVED
REPAIR
FINAL
RESIDUAL FIELD CHECK
GAUSS
DEMAGNETIZATION
PROCEDURE NO. :
TEST AREA :
METHOD:
MOBILE UNIT
HEAD SHOT/CLAMP
COIL/CABLE WRAP
CONDUCTOR
RESIDUAL
MEDIA:
PROD
AMP.:
CONTINUOUS
AC/DC
PRO-01WI-41
PARTICLE TYPE:
ARDROX 8800
KEROSENE
(SOLVENT MIX)
MAGNAGLO 14AM
RESIDUAL MAGNETISM :
GAUSS METER AT SURFACE:
COUPLING END
CENTER
HRUST END
(SPRAY CAN)
OTHERS
YOKE
AC
DC
PERMANENT
RUST PRESERVATION
INSPECTIONS RESULTS:
NO CRACK INDICATION ON ABOVE INSPECTED AREA, EXCEPT HEAVY RUBS. SEE THE ATTACHMENT
HR
INSPECTOR SIGNATURE
APPROVED BY
: ES
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-08 Rev.03
Page 1 of 3
PRODUCTION Form
HR
II
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
NDT. 01 / 036M / IV 14
APRIL 12, 2014
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-08 Rev.03
Page 2 of 3
PRODUCTION Form
HR
II
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
NDT. 01 / 036M / IV 14
APRIL 12, 2014
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-08 Rev.03
Page 3 of 3
FINAL
INSPECTION REPORT
CUSTOMER
MFG./MODEL
EQUIP./NO.
P.O. NO.
TSID PROJECT
:
:
:
:
:
PRO-01FR-44 REV.04
PRODUCTION Form
LP ROTOR
BEARING JOURNAL DIAMETER INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-01
AS RECEIVED
FINAL
1 2
SURFACES:
INSIDE DIAMETER
OUTSIDE DIAMETER
UNITS:
5 6 7
3 4
MILLIMETERS
INCHES
GOV. SIDE
GEN. SIDE
POS
379.25
379.24
379.25
379.25
379.25
379.24
379.25
379.24
90
379.23
379.23
379.24
379.25
379.24
379.24
379.25
379.24
NOTE:
1. ALL PHASE ANGLE RECORDED : 0 / 90
2. ZERO DEGREE POINTS IS: STAMP 1 ON DISK
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-55 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
BEARING JOURNAL HARDNESS INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-02
AS RECEIVED
FINAL
UNITS:
2 3 4 5
7 8
HRC
HRB
9 10
GOV. SIDE
GEN. SIDE
POS
HARDNESS
WELDING AREA
HAZ AREA
HAZ AREA
WELDING AREA
10
24.4 ~ 28.5
23.2 ~ 26.5
24.0 ~ 26.9
24.7 ~ 26.4
25.1 ~ 27.0
29.1 ~ 30.1
23.6 ~ 25.8
23.2 ~ 26.5
24.2 ~ 26.5
24.1 ~ 27.2
NOTE:
1. TAKE ON THE SURFACE OF CLOSE RUNNING CLEARANCE
PRO-01FR-78 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
SURFACE ROUGHNESS INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-03
AS RECEIVED
UNITS:
GEN. SIDE
- INCH
-M
GOV. SIDE
NO
SURFACE
ROUGHNESS (Ra)
0.17 ~ 0.20
0.12 ~ 0.19
0.17 ~ 0.18
0.22 ~ 0.23
PRO-01FR-90 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-04
AS RECEIVED
OTHERS/.
FINAL
SURFACES:
RADIAL
10
AXIAL
UNITS:
1/100 MILLIMETERS
11
2
1
1/10,000 INCHES
18
3
12
13 14 15 16
17
19
B2
A2
GOV. SIDE
GEN. SIDE
B1
A1
NOTE:
1. ALL PHASE ANGLE RECORDED : CCW AS VIEWED FROM GOV. SIDE.
2. ZERO DEGREE POINTS IS: STAMNP 1 ON DISK
3. ROTOR/SHAFT/PART IS SUPPORTED BY: V-BLOCKS
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-56 Rev.04
Page 1 of 2
PRODUCTION Form
LP ROTOR
RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-04
AS RECEIVED
FINAL
SURFACES:
RADIAL
AXIAL
UNITS:
1/100 MILLIMETERS
1/10,000 INCHES
POS
10
11
12
13
14
15
16
17
18
19
A1
A2
B1
B2
45
-05
-0.5
0.5
-0.5
-0.5
-1
-1
-0
0.5
-1
-1
-1
90
-0.5
0.5
-1
-1.5
-0.5
-2
-1
0.5
-1
-1
-2
-1
-1.5
135
-1
-1.5
0.5
-0.5
0.5
-0.5
0.5
-0.5
-1
-0.5
-1
0.5
-1
180
-1
1.5
-0.5
0.5
-0.5
0.5
-1
-2
-0.5
-0.5
-1
-0.5
-1
0.5
225
-1.5
-0.5
0.5
0.5
-0.5
0.5
0.5
-2
-0.5
1.5
-2
270
-1
0.5
-0.5
0.5
-2
0.5
-0.5
-1
-1
-1.5
315
0.5
0.5
-2
0.5
-0.5
-1
-1
-1.5
0.5
-1.5
TOTAL
1.5
1.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.5
NOTE:
1. ALL PHASE ANGLE RECORDED : CCW AS VIEWED FROM "GOV SIDE".
2. ZERO DEGREE POINTS IS: STAMP N0 "1" ON DISK.
3. ROTOR/SHAFT/PART IS SUPPORTED BY: V-BLOCKS
APPROVED BY: ASP
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-56 Rev.04
Page 2 of 2
PRODUCTION Form
LP ROTOR
PROBE AREAS ELECTRICAL RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-05
AS RECEIVED
ERO LOCATION
SURFACES:
RADIAL
AXIAL
UNITS:
MILLIMETERS
INCHES
: RADIAL GS
COMMENTS:
-
ACCEPTABLE
PRO-01FR-41 Rev.04
Page 1 of 2
PRODUCTION Form
LP ROTOR
PROBE AREAS ELECTRICAL RUNOUT INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-05
AS RECEIVED
ERO LOCATION
SURFACES:
RADIAL
AXIAL
UNITS:
MILLIMETERS
INCHES
: RADIAL TS
COMMENTS:
-
ACCEPTABLE
PRO-01FR-41 Rev.04
Page 2 of 2
PRODUCTION Form
LP ROTOR
BALANCE REPORT
(TWO PLANES)
MFG/MODEL
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BIFNL-06
INSPECTED BY: YD
BALANCE PROCEDURE:
FULL ASSEMBLY BAL.
TYPE OF ROTOR:
STEAM TURBINE.
CHECK BAL.
INDIVIDUAL BAL.
COMPRESSOR
WHEEL/DISK NUMBER:
CORR. METHOD:
MITSUBISHI / 200 MW
PUMP.
.
H 20 BU
ADDITIONAL
PROGRESSIVE BAL.
OTHER / GENERATOR
SHAFT ONLY
H 40 BU
REMOVAL
H6B
PERMANENT
ABRO
TEMPORARY
OTHERS
200 RPM
GRAMS, AT RADIUS
420
MM, AT
96
DEGREES, ON
GEN/S
SIDE.
1385
GRAMS, AT RADIUS
420
MM, AT
100
DEGREES, ON
GOV/S
SIDE.
GRAMS, AT RADIUS
420
MM, AT
45
DEGREES, ON
GEN/S
SIDE.
114
GRAMS, AT RADIUS
420
MM, AT
245
DEGREES, ON
GOV/S
SIDE.
GRAMS, AT RADIUS
420
MM, ON
GEN/S
SIDE.
177
GRAMS, AT RADIUS
420
MM, ON
GOV/S
SIDE.
b: 3120 . mm
c: 770 .mm
r2: 420 . mm
N/A
COMMENTS:
ACCEPTABLE
APPROVED BY: ASP.
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-30 Rev.04
Page 1 of 1
PRODUCTION Form
LP ROTOR
RESIDUAL UNBALANCE INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-07
INSPECTED BY: YD
STATUS:
INITIAL
FINAL
PLANE:1
COUPLING
EXCITER
GEN/S
TRIAL WEIGHT:650 Gr
AMP
PHASE
629
Gr.
Degree
689
Gr.
97
Degree
475
Gr.
183
Degree
470
Gr.
265
Degree
Gr.
Degree
Gr.
Degree
TRIAL UNBALANCE :
Y=
X=
420 x 650
200
400
600
800
100
00
RESIDUAL UNBALANCE :
273000x 109
659
PRO-01FR-23 Rev.04
Page 1 of 2
PRODUCTION Form
LP ROTOR
RESIDUAL UNBALANCE INSPECTION REPORT
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
BI-FNL-07
INSPECTED BY: YD
STATUS:
INITIAL
FINAL
PLANE:2
COUPLING
EXCITER
GOV/S
AMP
PHASE
655
Gr.
Degree
695
Gr.
93
Degree
645
Gr.
181
Degree
605
Gr.
274
Degree
Gr.
Degree
Gr.
Degree
200
400
600
800
100
0
RESIDUAL UNBALANCE :
273000 x 45
650
PRO-01FR-23 Rev.04
Page 2 of 2
PRODUCTION Form
PART NO.
1 UNIT
CH/ MN/ AM
II
ITEM DESCRIPTION
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
NDT. 01 / 015M / VI 14
JUNE 03, 2014
TEST PERFORMED:
LP ROTOR
AS RECEIVED
REPAIR
FINAL
RESIDUAL FIELD CHECK
GAUSS
DEMAGNETIZATION
PROCEDURE NO. :
TEST AREA :
METHOD:
MOBILE UNIT
HEAD SHOT/CLAMP
COIL/CABLE WRAP
CONDUCTOR
RESIDUAL
MEDIA:
PROD
AMP.:
CONTINUOUS
AC/DC
PRO-01WI-41
PARTICLE TYPE:
ARDROX 8800
KEROSENE
(SOLVENT MIX)
MAGNAGLO 14AM
RESIDUAL MAGNETISM :
GAUSS METER AT SURFACE:
COUPLING END
CENTER
HRUST END
(SPRAY CAN)
OTHERS
YOKE
AC
DC
PERMANENT
RUST PRESERVATION
INSPECTIONS RESULTS:
NO CRACK INDICATION ON ABOVE INSPECTED AREA, SEE THE ATTACHMENT :
CH
INSPECTOR SIGNATURE
ACCEPTABLE
APPROVED BY
: ES
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-08 Rev.03
Page 1 of 2
PRODUCTION Form
CH/ MN/ AM
II
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
NDT. 01 / 015M / VI 14
JUNE 03, 2014
Fig. 2
Fig. 4
Fig. 5
Fig. 6
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-08 Rev.03
Page 2 of 2
PRODUCTION Form
DEMAGNETIZATION
REPORT
INSPECTED BY
UT LEVEL
QTY
:
:
ES
III
PART NO.
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
ITEM DESCRIPTION
TEST PERFORMED:
AS RECEIVED
1 UNIT
LP ROTOR
REPAIR
FINAL
TEST AREA :
AMPERE
1000 1500 AMP
AC
YOKE 6
COUPLING END / DE
CENTER
INSPECTION RESULT :
HR
OPERATOR SIGNATURE
ACCEPTABLE
APPROVED BY
: ES
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-102 Rev.03
Page 1 of 3
PRODUCTION Form
DEMAGNETIZATION
REPORT
INSPECTED BY
UT LEVEL
:
:
ES
III
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-102 Rev.03
Page 2 of 3
PRODUCTION Form
DEMAGNETIZATION
REPORT
INSPECTED BY
UT LEVEL
:
:
ES
III
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
REPORT NO.
DATE
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-102 Rev.03
Page 3 of 3
PHOTOGRAPHS
CUSTOMER
MFG./MODEL
EQUIP./NO.
P.O. NO.
TSID PROJECT
:
:
:
:
:
PRO-01FR-44 REV.04
PRODUCTION Forms
PHOTOGRAPHS
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-32 Rev.04
Page 1 of 3
PRODUCTION Forms
PHOTOGRAPHS
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-32 Rev.04
Page 2 of 3
PRODUCTION Forms
PHOTOGRAPHS
MFG/MODEL
MITSUBISHI / 200 MW
TBA / UNIT #5
CUSTOMER
TSID PROJECT
P-01267
This material is the exclusive property of PT. Sulzer Turbo Services Indonesia
PRO-01FR-32 Rev.04
Page 3 of 3