Measuring Task Silicon oil dosing -


Flow measurement and control of the silicon oil dosing. stopper washing
Pipe: 42.4 x 2 mm machine
Material: 1.4571
Temperature: 20 °C ...130 °C

Instruments Used Customer


?
FLUXUS ADM7207
Transducers
Q3N7-F

Advantages
• small dimensions of the transducers in comparison to a coriolis meter
• contact free and hygienic safe measurement
• no installations in the piping, no stream divider ATEC - Pharmatechnik GmbH
• suitable for CIP 24955 Harrislee
• no pressure drop
• economic price for the whole loop against the whole costs with
installation of a coriolis meter, standard transducers stainless steel.

Description
Usually medicament bottles are closed by rubber stoppers. This rubber
stoppers can be penetrated by a cannula to take out the medicament.
According to a GMP-regulation this stoppers have to be washed in an
emulsion of water and silicon oil. Afterwards the stoppers need to be
sterilised at 130 °C. ATEC developed mutually with Steritech a very
economically concept of the washing plant.

FLUXUS®, WaveInjector® , and PIOX® are protected trademarks of FLEXIM GmbH. Copying and distribution allowed only with the written permission of
FLEXIM GmbH. The copyright of this report, its components, content and pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of
this application report is solely to give general information about the application. It does not assure the suitability of the instrument for a specific purpose.
AR-200002-Atec-EN.doc, 23/07/01, Page 1 of 1