STAAD PLANE FRAME ANALYSIS FOR RCC DRAIN 3 m x 3 m

INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0.00 0.00 0.00
2 3.350 0.00 0.00
4 0.00 3.175 0.00
3 3.350 3.175 0.00
5 0.175 0.00 0.00
6 3.175 0.00 0.00
7 3.175 0.000 0.175
8 0.00 0.175 0.00
9 0.604 0.00 0.00
10 1.033 0.00 0.00
11 1.462 0.00 0.00
12 1.891 0.00 0.00
13 2.320 0.00 0.00
14 2.749 0.00 0.00
MEMBER INCIDENCES
148
281
315
459
5 9 10
6 10 11
7 11 12
8 12 13
9 13 14
10 14 6
11 6 2
12 7 2
13 3 7
MEMBER PROPERTIES
3 11 PRIS YD 0.35 ZD 1.0
4 to 10 PRIS YD 0.35 ZD 1.0
1 13 PRIS YD 0.35 ZD 1.0
2 12 PRIS YD 0.35 ZD 1.0
CONSTANTS
E 25000000 ALL
POISSON 0.15 ALL
DENSITY 25 ALL
ALPHA 1.17e-005 ALL
SUPPORTS
1 2 FIXED BUT FX FZ MX MY MZ KFY 262.500
5 6 FIXED BUT FX FZ MX MY MZ KFY 906
9 TO 14 FIXED BUT FX FZ MX MY MZ KFY 1287
LOAD 1 DEAD LOADS
MEMBER LOADS
3 TO 11 UNI GY -14.750

1 13 CONC GY -26.25
LOAD 2 EARTH PRESSURES
MEMBER LOADS
1 TRAP GX 0 18
2 TRAP GX 18 20
13 TRAP GX 0 -18
12 TRAP GX -18 -20
1 TO 2 UNI GX 7.13
12 TO 13 UNI GX -7.13
LOAD COMB 3 LOAD COMBINATION
1 1.0 2 1.0
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
PRINT SUPPORT REACTION
PRINT FORCE ENVELOPE NS 10
FINISH