Malfunction
MID 128 SID 42 Fuel control unit

Fault code

FMI 5

FMI 3

Open circuit or short circuit to voltage (high voltage side).


Also sets PPID97 FMI14.

Short circuit to voltage (low voltage side).


Also sets PPID97 FMI14.

Conditions for fault code:


Short circuit to voltage (low voltage side).
Possible cause:
Short circuit to battery voltage in the component or
wiring.
Reaction from engine control unit:
Fault code is set.
Yellow lamp requested.
Noticeable external symptoms:
Yellow lamp lights.
The over-pressure valve is open.
Power reduction.
Appropriate action:
MID 128 SID 42 Fuel control unit, check page 3

FMI 4
Short circuit to ground (high voltage side).
Also sets PPID97 FMI14.

Conditions for fault code:


Short circuit to ground (high voltage side).
Possible cause:
Short circuit to ground in the component or wiring.
Reaction from engine control unit:
Fault code is set.
Yellow lamp requested.
Noticeable external symptoms:
Yellow lamp lights.
The over-pressure valve is open.
Power reduction.
Appropriate action:
MID 128 SID 42 Fuel control unit, check page 3

Conditions for fault code:


Open circuit or short circuit to voltage (high voltage
side).
Possible cause:
Open circuit or short circuit to voltage (high voltage
side) in the component or wiring.
Reaction from engine control unit:
Fault code is set.
Yellow lamp requested.
Noticeable external symptoms:
Yellow lamp lights.
The over-pressure valve is open.
Power reduction.
Appropriate action:
MID 128 SID 42 Fuel control unit, check page 3

FMI 6
Short circuit to ground.

Conditions for fault code:


Short circuit to ground in the component or wiring.
Possible cause:
Short circuit to ground in the component or wiring.
Reaction from engine control unit:
Fault code is set.
Yellow lamp requested.
Noticeable external symptoms:
Yellow lamp lights.
The over-pressure valve is open.
Power reduction.
Appropriate action:
MID 128 SID 42 Fuel control unit, check page 3

Volvo Truck Corporation


Service Bulletin

Date

Group

No.

Release

6.06

284

50

01

Page
3(4)

28321-3
MID 128 SID 42 Fuel control unit, check
Special tools: 9990014, 9990216, 9998699
Other special equipment: 9812519
Fault code information, see MID 128 SID 42 Fuel
control unit page 2.

NOTE!

Active/inactive fault code


Certain fault codes become inactive when the engine is
shut off. Start the engine to see if the fault code is still
inactive or becomes active when the engine is running.
Connector block
Always check that there is no oxidisation and that the
pins in the connector are not damaged. Also check the
grip of the pins. For more information, refer to Function
Group 3710, Information type Diagnostics, 37102-3
Electric wires and connections, check.
If the connector is free from faults, reconnect it.
Check if the fault code is still active. If the fault code
is still active, continue fault tracing according to
the instructions.
After any corrective actions on the connector block
Refit the connector. Check if the fault code has
become inactive.
If the fault code is still active, continue fault tracing
according to the instructions.

Measurements
Note: If any of the following cable measurement values
are faulty, they may have caused the component to be
damaged. Check also if any of the components values
are faulty.

Component:
1
Conditions:
Adapter connected towards component
Starter key in stop position.
Measure resistance using a multimeter.
Measurement points

Expected value

1-2

R3

1 - Ground

Circuit break

9990216
9812519
T2023306

Volvo Truck Corporation


Service Bulletin

Date

Group

No.

Release

6.06

284

50

01

Cabling
2

T2023702

T2023307

Conditions:
Adapter connected towards cable harness.
Break-out box and adapter connected towards
cable harness.
Starter key in stop position.
Measure resistance using a multimeter.
Measurement points

Expected value

1 - EA12

R0

2 - EA16

R0

9990014, 9990216, 9998699