Sunteți pe pagina 1din 2

6/12/2016

3412GeneratorSet4BZ00001UP(SEBP278548)/BasicSearch

PreviousScreen

Welcome:apache03
Product:GENERATORSET
Model:3412CGENERATORSET4BZ
Configuration:3412GeneratorSet4BZ00001UP

ServiceMagazine
2014/09/16
MediaNumberSEPD185200

PublicationDate16/09/2014

DateUpdated16/09/2014

i05427731

UpdatedFlashProcedureforAllCaterpillarProducts{1920,
7610,7620}
SMCS192076107620

CaterpillarProducts:thatUseFlashProgramming
All
CaterpillarProducts:
All
ServiceMagazineSEPD1635,11July2013,"UpdatedFlashProcedureforAllCaterpillarProducts
{1920,7610,7620}".Disregardtheinformationinthearticlethatislistedabove.Refertothe
informationinthefollowingarticle.
Note:TheinformationcontainedinthisarticleisspecificallyforCatProductsthatuseflash
programming.
InordertoupgradetheECMsoftware,theECMmustbeflashed.FlashprogrammingoftheECM
mustalsobedoneiftheECMhasbeenreplaced.TheCatElectronicTechnician(CatET)Service
ToolcontainstheprogramWinFlash.WinFlashisusedtoloadsoftwareintotheECM.Toavoid
communicationissues,performthefollowingproceduretoFLASHsoftwareintotheECM.
Note:ThisarticlecanbeusedasageneralguideforECMflashing,onallCaterpillarProducts.If
issuesarestillpresentafterconductingthefollowingprocedure,referencetheproductspecific
publicationsforfurtherinstructions.

ProceduretoFlashProgramtheECM
Note:BeforeflashinganyECM,ensurethatthetransmissiondirectionswitchisintheneutral
position.Ensureboththeimplementlockoutandparkingbrakeswitchesareinthelockedposition.
TurnkeystartswitchtotheONposition.Waitafull2minutestoallowallECMstoinitialize
communications.
1.ConnecttheDataLinkcablebetweenCommAdapterIIIandmachineserviceport.
2.ConnecttheUSBPCconnectorcablebetweenCommAdapterIIIandlaptop.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/fulltext/fulltextheaderinfoframeset.jsp&calledpage=/sisweb/sis 1/2

6/12/2016

3412GeneratorSet4BZ00001UP(SEBP278548)/BasicSearch

3.StartCatET.
4.VerifythatthecorrectCatETpreferencesareselectedforCommAdapterIII.
Note:ToverifythatCatETpreferencesarecorrectfortheCommAdapterIII.Navigateto
Utilities>Preferences>Modify.Underthe"Communications"tab,select"CaterpillarComm
Adapter3(RP1210)"fromthedropdownbox.Ensurethe"EnableDualDataLinkService"
boxisselected.
5.ConnecttoCatET.
6.RunProductStatusReport(PSR).
7.CopytheECMReplacementFilesforallECMs.
8.Takenoteofanyactivediagnosticcodes,andclearloggeddiagnosticcodes.
9.ConnecttoWinFlash.
10.DeterminewhichECMistobeflashed,andthenloadflashfile.
Note:IfflashingmultipleECMs,takenoteifaspecificorderistobefollowed.
11.VerifythatflashfileiscorrectforthespecificECM,andthenbeginflash.
12.Oncecomplete,returntoCatET.
13.RunthepostflashProductStatusReport.
14.Beforepoweringdown,performallcalibrations,clocksyncetc.Allowmachinetooperatefor
atleast10minutestoallownewparameterstobeaccepted.
15.Afterpoweringdownthemachine,wait3minutesbeforecyclingthemachinetotheONor
START/RUNstate.Waiting3minutesprovidestheECM(s)timetoshutdown.
Copyright19932016CaterpillarInc.
AllRightsReserved.
PrivateNetworkForSISLicensees.

SunJun12201613:24:22GMT+0200(EgyptStandardTime)
apache03

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/fulltext/fulltextheaderinfoframeset.jsp&calledpage=/sisweb/sis 2/2