Documente Academic
Documente Profesional
Documente Cultură
ATTENTION:
DT-ENG-QSG-V1 20091221
-1-
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 56
IN-USE
Code=32, DIP-6=on
ON
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=31, DIP-6=off
ON
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=2, DIP-6=off
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
IN-USE
Code=1, DIP-6=off
3
PS5
DPS
85~260AC
Cable Usage
60
60
80
80
1
ID=00
123456
Cable Usage
70
30
70
50
ON
-2-
ON
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=32, DIP-6=on
7
ON
CALL
DBC
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=31, DIP-6=off
6
ON
CALL
DBC
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=8, DIP-6=off
6
ON
CALL
DBC
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=1, DIP-6=off
C
3
PS5
DPS
85~260AC
1
ID=00
123456
ON
Cable Usage
60
60
30
80
80
40
-3-
Cable Usage
70
30
20
70
50
30
C
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
IN-USE
Code=31, DIP-6=on
DBC-4
A B C D
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
IN-USE
HI
OUT IN
Code=32, DIP-6=on
IN-USE
IN-USE
Code=29, DIP-6=on
Code=30, DIP-6=on
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
IN-USE
1 2 3 4 5 6
IN-USE
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
DBC-4
CALL
UNLOCK
TALK/MON
A B C D
ON
OUT IN
Code=3, DIP-6=on
Code=4, DIP-6=on
HI
IN-USE
IN-USE
Code=1, DIP-6=on
Code=2, DIP-6=on
3
DPS
PS5
85~260AC
1
ID=00
123456
ON
[1]: Door Station, when there is only one Door Station, the DIP bit-1 and
bit-2 should be set to 00.
[3]: Power Separator, MUST be installed side by side with the PS5 unit.
60
60
30
[4]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
80
80
40
[2]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[5]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
[6]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to 120 as it is at the end of the bus line.
-4-
70
30
20
70
50
30
ON
CALL
UNLOCK
TALK/MON
IN-USE
ON
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
Code=3, DIP-6=on
OUT IN
Code=4, DIP-6=on
CALL
UNLOCK
TALK/MON
ON
IN-USE
1 2 3 4 5 6
1 2 3 4 5 6
Code=2, DIP-6=on
Code=1, DIP-6=on
7
DPS-4
BUS
6
PS5
DPS
A B C D
CALL
UNLOCK
TALK/MON
IN-USE
DBC-4
A B C D
ON
HI
1 2 3 4 5 6
85~260VAC
ID=00
ID=10
123456
123456
ON
ON
ID=01
ID=11
123456
123456
ON
ON
[1]: The first Door Station, the DIP bit-1 and bit-2 should be set to 00.
[2]: The 2nd Door Station, the DIP bit-1 and bit-2 should be set to 01.
[3]: The 3rd Door Station, the DIP bit-1 and bit-2 should be set to 10.
[4]: The 4th Door Station, the DIP bit-1 and bit-2 should be set to 11.
[5]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[6]: Power Separator, MUST be installed side by side with the PS5 unit.
[7]: DPS-4(4 input Power Separator), can connect Max. 4 Door Stations.
[8]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
[9]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
-5-
60
60
30
80
80
40
70
30
20
70
50
30
ON
CALL
UNLOCK
ON
TALK/MON
IN-USE
IN-USE
1 2 3 4 5 6
8
HI
1 2 3 4 5 6
Code=3, DIP-6=on
CALL
UNLOCK
TALK/MON
TALK/MON
IN-USE
IN-USE
1 2 3 4 5 6
DBC-4
ON
UNLOCK
A B C D
CALL
OUT IN
Code=4, DIP-6=on
ON
CALL
UNLOCK
TALK/MON
1 2 3 4 5 6
Code=2, DIP-6=on
Code=1, DIP-6=on
6
AC
7
ON
123456
DCU
DPS
PS5
85~260VAC
10
10
ID=00
123456
ON
[1]: The first Door Station, the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[3]: Power Separator, MUST be installed side by side with the PS5 unit.
[4]: DCU(CCTV Controller), can connect Max.2 CCTV cameras and
lamp/lock at the same time.
[5]: Light turn on button.
[6]: AC input for the lamp.
60
60
30
80
80
40
[7]: Lamp.
[8]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
[9]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
[10]: CCTV camera.
-6-
Cable Usage
70
30
20
70
50
30
L(AC): AC input.
N(AC): AC input.
L (AC)
65
N (AC)
97
VV+
2-
VADJ
24
: Earth Ground.
LED
78
159
6.5
150
22
117
38
18
Unit: mm
DIN Installation
PS5
DPS
DIN nail
85~260AC
Electronic Specifications
Input Voltage:
85~260Vac, 120~370Vdc
Input Frequency:
47~63 Hz
Leakage Current:
>2mA / 240Vac
AC current (TYP.)
-7-
DPS
Connect to
Power Supply(PS5)
Technical Specifications(DPS)
Power input:
Power output:
Connect to Monitor
18Vdc
-5C +45C
DBC
Technical Specifications(DBC)
Bus In/Out
Power Consumption:
Working temperature:
85mm
-8-
DBC-4
HI
Video Match
120
In-use
Power
Trunk Bus
Bus Out
Bus In
Connect to Monitors
Connect to
Monitor/Distributor
Connect to DPS
Connect to Door Stations
-9-
114.5
mm
298.5 mm
45
mm
ON
L2
JP-LK
PB
BUS
- 10 -
PA
SET
CN-LK
L1
1
2
3
123456
T/R T/R+
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Note
The double button line expansion panel can only
be connected to double button line Door Station;
the single button line expansion panel can only be
connected to single button line Door Station. For
example, the EP11/Dx can only be connected to
DMR11/Dx Door Station.
RS-485
Stopper
ON
ON
Bit state
1 2 3 4 5 6
ON 1 2 3 4 5 6
Bit definition
OFF(0)
Function Descriptions
Default setting, ID = 0, set to the first Door Station.
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Bit-3
User ID select
Bit-4
Button line select
Bit-5
Unlocking time quick
select
Bit-6
Function reserved
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Working state.
ON
1 2 3 4 5 6
Function reserved.
ON
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
123456
ON
T/R T/R+
DMR11
Connection Board
Exit Button
L1
PA
L2
BUS
JP-LK
1
2
3
PB
- 11 -
SET
RS-485
Electronic Lock
POWER
IN-USE
CALL
UNLOCK
S1
ON
TALK/MON
IN-USE
INTERCOM
123456
S1
UNLOCK
TALK/
MONITOR
SW+
SWEXT-RING
GND
VIDEO
SW+
SWEXT-RING
GND
VIDEO
ON
123456
L1
L2
BT1
BT2
EH
GND
VD
DIPS
123456
ON
L1
L2
L1
L2
DIPS
BT1
BT2
EH
GND
VD
ON
123456
L1
L2
31
32
16
28
29
30
15
27
27
28
14
26
25
26
13
25
23
24
12
24
21
22
11
23
19
20
10
22
17
18
09
21
07
08
15
16
04
08
20
05
06
13
14
03
07
19
03
04
11
12
02
06
18
01
02
09
10
01
05
17
DMR11-D8
EP11-D24
DMR11-S4
- 12 -
EP11-S12
EP11-S12
ON(1)
ON 1 2 3 4 5 6
ON
Bit state
ON
User Code
Code=1
1 2 3 4 5 6
ON
Code=2
Code=3
Code=4
Code=5
Code=6
Code=7
Code=8
Code=9
ON
ON
ON
ON
ON
ON
ON
ON
Code=10
ON
Code=14
ON
Bit state
ON
ON
1 2 3 4 5 6
Setting
Monitor at
the end of
the line.
User Code
Code=23
ON
Code=24
ON
Code=25
1 2 3 4 5 6
Code=15
ON
Code=26
1 2 3 4 5 6
Code=16
ON
Code=27
1 2 3 4 5 6
Code=17
ON
Code=28
1 2 3 4 5 6
Code=18
ON
Code=29
1 2 3 4 5 6
Code=19
ON
Code=30
1 2 3 4 5 6
Code=20
ON
Code=31
1 2 3 4 5 6
Code=21
1 2 3 4 5 6
Code=11
Monitor not
at the end of
the line.
Bit
state
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
Code=13
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
Setting
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
Code=12
1 2 3 4 5 6
1 2 3 4 5 6
ON
User Code
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
1 2 3 4 5 6
ON
Bit state
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
1 2 3 4 5 6
ON
Bit
state
OFF(0)
ON
1 2 3 4 5 6
Code=22
1 2 3 4 5 6
- 13 -
Code=32
Show theMASTER
CARD ADD card to
run format operation.
- 14 -
Note 1: The MASTER CARD ADD card must be showed before the Reader can get
in to the Authorize DELETE-Card state, and make sure each operation have to take
place within 10 seconds, or the Door Station will return to normal state automatically.
Operation
Sound hint
standby state
LED-A
LED-B
LED-C
LED-D
Standby
ON
ON
ON
ON
Authorize ADD-Card
ON
OFF
OFF
ON
Authorize DELETE-Card
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
LED-D
OFF
ON
OFF
OFF
LED-B
Format
ON
ON
OFF
OFF
- 15 -
LED-C
LED-A
DMR11/ID/D8
5. Quik Debug
5.1. Online search
Online search function is designed for the purpose of getting a quick view of the Monitors installing situations, or to check if each of
them works or not. It is very useful for installation maintain.
When the Online search is acting, the Door Station will search every Monitor with the User Code from 1 to 32. If the Monitor is one
line(work normally), the LED light of that button will light up, and one 'Di~' sound hit will be heared; if the Monitor is off line(disconnected
or malfunctioning), the LED light of that button will not light up, and a 'Di,Di,Di' sound hit will be heard. After 32 Monitors all be searched,
the Monitor will quit out automatically, or press PB button to abort the searching.
T/R T/R+
L1
L2
RS-485
L2
BUS
PA
PB
BUS
16666666
DMR11/ID/D8
For Example, if 01, 03, 04, 11, 12, 13, 28 Monitors are installed and work correctly, the result will be:
31
32
31
32
31
32
31
32
29
30
29
30
29
30
29
30
27
28
27
28
27
28
27
28
26
25
26
25
26
25
26
25
23
24
23
24
23
24
23
24
21
22
21
22
21
22
21
22
19
20
19
20
19
20
19
20
17
18
17
18
17
17
18
16
07
08
15
16
13
14
05
06
13
14
04
11
12
03
04
11
12
02
09
10
01
02
09
10
07
08
15
05
06
03
01
18
07
08
15
16
07
08
15
16
05
06
13
14
05
06
13
14
03
04
11
12
03
04
11
12
01
02
09
10
01
02
09
10
PB button
Online search range
5.2. Auto-CallBack
The Auto-Callback function is designed for the purpose of testing the
Monitor's working state, which enable the installer to check a certain
Monitor working state by only one person.
CALL
Calling...
UNLOCK
TALK/MON
IN-USE
Press and hole the Call Button for 2 seconds on any Monitor, the Door
Station will call the Monitor automatically, then the installer can answer
the call and check if system work properly(such as video, audio etc).
- 16 -
PA
PB
SET
123456
ON
CN-LK
1
2
3
L1
1
2
3
JP-LK
T/R T/R+
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
MENU
SET
DMR11
Connection Board
Press the PB button, will search the Monitors in the right Call
Buttons column.
Press the PB button and hold for 3 seconds, will search the
Monitors in the left Call Buttons column.
123456
ON
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
CN-LK
RS-485
A. Manual search