Documente Academic
Documente Profesional
Documente Cultură
GDO-11v1 SecuraLift
Overhead Garage Door Opener
Features
Operating Controls
Kit Contents
10
Installation
11
11
C-Rail Attachment
13
14
15
25
16
Key switch
25
17
Auxiliary output
25
18
26
SmartSolar Installation
27
19
Final Set Up
25
28
20
28
20
28
Re-Initialising
28
29
Accessories
22
Parameters
30
Door
22
Vacation Mode
22
30
22
Button functions
30
Pet Mode
23
Troubleshooting Guide
31
Courtesy Light
23
Maintenance Record
32
24
Parts Listing
33
24
Warranty
34
The unit should be installed so that it is protected from the elements. It should not be exposed to water or rain.
It is not to be immersed in water or sprayed directly by a hose or other device.
The garage door must be well balanced. Sticking or binding doors must be repaired by a qualied garage
door installer prior to installation of the opener.
Frequently examine the installation, in particular cables, springs and mountings for signs of wear, damage
or imbalance. DO NOT use if repair or adjustment is needed since a fault in the installation or an
incorrectly balanced door may cause injury. DO NOT attempt to repair the door yourself as hardware
is under extreme tension.
Remove or disengage all garage door locks and mechanisms prior to installation of the opener.
Connect the opener to a properly earthed general purpose 240V mains power outlet installed
by a qualied electrical contractor.
Disconnect the power cord from mains power before making any repairs or removing
covers. Only experienced service personnel should remove covers from the opener.
In order for the SecuraLift to sense an object obstructing the door way, some force
must be exerted on the object. As a result the object, door and/or person may
suffer damage or injury.
If the power supply cord is damaged, it must be replaced by an Automatic
Technology service agent or suitably qualied person.
Make sure that the door is fully open before driving in or out of the garage
and fully closed before leaving the driveway.
Make sure that remote controls are kept out of reach of children.
Install the (optional) wall switch or (optional) wall mounted
transmitter in a location where the garage door is visible, but
out of the reach of children at a height of at least 1.8 meters
from the oor.
Features
Thank you for purchasing the Automatic Technology
GDO-11v1 SecuraLift Overhead Garage Door
Opener. Designed to suit sectional overhead and one
piece tilt up doors, the components and materials
used ensure this opener will provide years of
smart, simple and secure operation. Listed
below are some of the many features:
Operation
To open or close the door simply press a button on a TrioCode handheld
transmitter, or optional wall switch for two seconds. During open and close cycles
the door can be stopped by pressing the button again. The next actuation will
move the door in reverse direction.
Vacation mode
A hand held transmitter can be programmed to lock and unlock all other
transmitters that have been programmed into the openers memory. The vacation
mode can be used when the door is left idle for long periods of time.
Pet/Pedestrian mode
The transmitter can be programmed to open the door to an adjustable partial
height so that the family pet can enter and exit the garage at any time. You may also
wish to open the door to a height suitable only for pedestrian access.
Manual operation
The opener is equipped with a unique manual disengaging device. If the power to the opener
is disrupted the door can be put into manual mode by pulling down on the string handle on an
angle towards the door. This allows for manual operation of the door. To re-engage the opener pull
the string handle away from the door.
Operating controls
01
Terminal Block.
02
CODING LED (red) light ashes when a code is being stored or when a transmitter button is pressed.
03
DOOR CODE BUTTON is used for storing or erasing transmitter buttons for door operation
04
05
SET button (Orange) is used during the installation phase together with the Open and MINUS (-) buttons
to set the door limit positions. The Set button is also used to re-initialize the Opener.
06
OPERATE button (Yellow) is used during installation to test the open, stop and close cycles for the
07
08
09
10
opener. The opener has to be initialised by the set button to make the OPERATE button operable.
FORCE MARGIN SET Button: The obstruction force margin is set automatically during installation. The
margin can be adjusted manually using the Force Margin Set button (White). Holding the Force Margin Set
button and pressing PLUS (+) or MINUS (-) buttons will increase or decrease the amount of force. The Force
Margin Set should only be used if environmental factors (wind, etc.) affect the doors operation.
OPEN LIMIT LED (green) the LED is very helpful during installation. It illuminates and ashes when the
door is opening and remains steady on when the open limit position has been reached.
PLUS (+) button (green) is used during installation to help set the open limit position. Pressing and holding
this button will move the door in the open direction, releasing stops the door.
NOTE: The safety obstruction detection is inoperable when the PLUS (+) button is used to move door.
CLOSE LIMIT LED (red) the LED is very helpful during installation. It illuminates and ashes when the
door is closing and remains steady on when the close limit position has been reached.
11
MINUS (-) button (red) is used during installation to help set the close limit position. Pressing and holding
12
DATUM ADJUST SCREW is used during limits set up to indicate the mid point of the doors travel.
13
10A FUSE
14
this button will move the door in the close direction. Movement stops when the button is released.
NOTE: The safety obstruction detection is inoperable when the CLOSE button is used to move door..
PROG INPUT is used to connect the Automatic Technology Handheld Programmer PG-3 for editing
control and receiver functions, accessing diagnostic tools, and activating special features and operating
modes.
15
JP1 SOLAR CONNECTOR onto this the shunt must be tted for solar operation.
16
COURTESY LIGHT 15 watts 24 volts feston type globe is used for courtesy light
12
g 01
02
01
03
04
05
06
07
08
09
10
11
16
15
14
13
Kit contents
GDO-11v1 Multipiece C Rail And Accessory
1 x GDO-11v1 SecuraLift Ero drive unit (Fig. 02)
1 x TrioCode Transmitter pack (Fig. 02)
(Pack includes 1x four button keyring transmitter and
1x two button keyring transmitter with batteries)
2 x Door attachment arms (Fig. 02)
1 x Accessory and hardware pack (Fig. 02)
1 x Chain (Fig. 02)
1 x C rail track pack (Fig. 02)
(Pack includes three C rail sleeves and four C rail tracks)
1 x Shuttle assembly (Fig. 02)
1 x Installation Manual
g 02
OR
g 03
PLUS
Pre-Assembled Single Piece C-Rail
Note: The chain or belt in the single piece rail has been
tensioned by the factory.
g 04
10
c.
d.
e.
f.
Tr
ac
k
g 05
Sle
ev
e
Te
ns
ion
as
se
mb
ly
Do
or
en
d
Op
en
er
en
d
g 06
Ch
ain
Idler pulley
g 07
Ho
le
11
h.
en
d
i.
g 08
12
te
et
hs
pr
oc
ke
t
j.
k.
9 teeth sprocket
g 09
Tension hex bolt
Do
or
en
d
Op
en
er
en
d
g 10
12
C-Rail Attachment
Step 2 - Secure C-Rail to Drive Unit
a.
b.
Shaft
Locate and insert the shaft of drive unit into the CRails sprocket (Fig. 11).
Fix the two track brackets with four screws supplied
in accessory pack (Fig. 12).
g 11
Locate shaft into sprocket
g 12
13
g 13
Door
g 14
g 15
14
Level
Level
Track
g 16
Door
b.
c.
4 .5
1
52
21.
g 17
Drilled holes
b.
b.
c.
d.
e.
Structural member
g 19
15
Centre of Door
g 20
b.
g 21
Step
ladder
b.
c.
d.
e.
C rail
f.
g.
g 22
Highest point
of door travel
Door
Step
ladder
h.
a.
b.
g 23
Ceiling
Steel Rail
Shuttle Assembly
16
b.
g 24
Straight arm
connected to the
shuttle
g 25
10
g 26
g 27
17
Setting Limits
NOTE: If P.E. Beams are to be used they must be
installed before setting the travel limits.
g 28
b.
g 29
b.
c.
Press and hold the MINUS (-) button until the door
reaches the desired close limit position. Single
presses will inch the door closed (Fig 30)..
Press the LIMIT SET button to store the close position
into memory (Fig. 30)
Press and hold the PLUS (+) button until the door
reaches the desired open limit position. Single
presses will the inch the door open (Fig. 30).
IMPORTANT
WARNING: The door will
automatically close, open and close again once
Step 14.4(d) is performed. Ensure that no persons
or objects are in the doors path.
a.
d.
g 30
18
g 31
c.
b.
c.
d.
e.
Button 1
(Inch Open)
Button 4
(Inch Close)
Button 2
(Set)
g 32
IMPORTANT
WARNING: The door will
automatically close, open and close again once
Step 15.3 (f) is performed. Ensure that no persons
or objects are in the doors path.
f.
g.
19
g 33
g 34
c.
c.
20
g 35
c.
d.
c.
d.
g 36
b.
c.
d.
Press and hold the SET Button for two (2) seconds,
the beeper will sound once (Fig. 37).
The door will start to move and re-calculate force
margins. The door can move between the open and
close limit positions up to four (4) times (depending
on the position of the door and the power up
condition).
A single beep will be heard once the process is
complete.
Test the force again as per Steps 16.1 and 16.2.
g 37
21
Coding Transmitters
Step 18.1 - Code a Transmitter Button for
Door Operation
a.
b.
g 38
c.
d.
b.
c.
d.
e.
g 39
b.
c.
d.
g 40
22
Coding Transmitters
Step 18.4 - Code a Transmitter Button for Pet
(Pedestrian) Mode
a.
b.
c.
d.
e.
g 41
23
g 43
a.
b.
c.
d.
e.
g 44
a.
b.
c.
d.
c.
g 45
24
d.
P.E. Beams
Step 20 - Fitting the P.E. Beams (optional)
b.
c.
Receiver
Transmitter
Model PE-2
RED
RED
RED
RESISTOR = 2K2
0.25 WATT
+ -
+ -
g 46
BLACK
BLACK
BLACK
BLACK
YELLOW
RED
RED
RED
YELLOW
PWR
PE
PE(0V )
GND
OSC
AUX OUT
GOLD
a.
g 47
30V PWR
PE
PE (0V)
GND
OSC
AUX OUT
External
device
Alarm, Door
opener etc.
PWR
PE
PE(0V )
GND
OSC
AUX OUT
g 48
25
g 49
c.
d.
e.
f.
g.
h.
i
j
26
SmartSolar Installation
WARNING: Do not connect batteries until Step
24.3
c.
d.
e.
f.
g.
S
Fig 50
Fig 51
Black
Yellow
Red
e
Whit
f.
Red (From Ba
ttery)
e.
ttery)
d.
Fig 52
Black (From Ba
c.
a.
b.
olar Panel)
Black (From S
ire
W
ck
ire
a
l
B
dW
e
R
Fig 53
27
Final Set Up
Step 25 - Setting the Pet Mode position
The default Pet Mode height can be changed as follows:
a. Make sure the door is closed, then press and hold
the PLUS(+) button for six (6) seconds (Fig. 54),
until you hear three beeps and the OPEN and
CLOSE LEDs ash rapidly.
b. Press the OPEN or CLOSE button to move the
door to the desired pet mode open position.
c. Press the SET button to record the new position.
g 54
c.
d.
g 55
g 56
28
Step
Maximum
60 Secs.
3 Mins.
10 Sec in battery back
up mode
0.5 Amp
0.1
2 Amp
Technical specications
Power supply
Transformer rating
72 VA
Standby power
2.2 Watts
Motor power
90 Watts
Motor type
5500mm (12m2)
2150mm
80 kg
Width:
Height:
Weight:
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
650N (65kg)
Lift force
400N (40kg)
Nominal force
150N (15kg)
Receiver type
Multi-frequency FM Receiver
Transmitter frequency
~= to 433.92 MHz
Coding type
TrioCode
Code generation
Transmitter battery
CR 2032
Courtesy light
Controller fuse
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind
puts extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system
intermittently.
P.E Beams should be tted as added safety in case of entrapment.
29
Parameters
Door Status Indicators
Door Opener State
Open
On
Close
Opening
Beeper
On
Flashing
Closing
Flashing
Flashing
Flashing
Flashing
Flashing
Opener overloaded
Alternating ashes
Alternating ashes
On
On
Rapid ashes
Button Functions
30
Buttons
Function
OPERATE
DOOR CODE
SET (then power on) & hold until all LEDs are off
DOOR CODE (then power on) & hold until all LEDs
are off
SET & DOOR CODE (the power on) and hold until all
LEDs are off
SET
Troubleshooting guide
Symptom
Door will not operate
Possible cause
Remedy
Door is obstructed
Remove obstruction
Possible obstruction in
the doorway
Door operates from drive unit
(operate) button but not from
transmitter.*
*See note
Remove obstruction
Code transmitter into openers
memory. Refer Step 18.1 on page
22
Replace battery
Faulty light
Replace lamp
Remove obstruction
See Step 20 on page 25
PLEASE NOTE:
Some areas may be prone to excessive radio interference brought on by devices such as cordless telephones,
wireless stereo headphones and baby monitors. It is possible that these devices could cause a degree of
interference such as to greatly reduce the range of the transmitter. In such an instance please contact your ATA
dealer for an alternative frequency replacement kit. As this is not a warrantable situation but an environmental
issue charges may apply for the changeover.
31
Maintenance
Maintenance
Yearly
Monthly
Service Record
Record any maintenance in the following table to assist in any warranty service.
Date
32
Service by
Signature
Invoice No.
Amount
Parts Listing
33
34
35
August 2008 Automatic Technology (Australia) Pty Ltd. All rights reserved. TrioCode and SecuraLift are trademarks
of Automatic Technology (Australia) Pty Ltd. No part of this document may be reproduced without prior permission. In an
ongoing commitment to product quality we reserve the right to change specication without notice. E&OE.