All Turbine protections shall act to de-energise Turbine trip solenoids, thereby closing
the ESV’s and respective control valves.
15. Lube Oil Pressure very Low < 3.4 < 3.2
kg/cm2 kg/cm2
16. Control Oil Pressure very Low < 120 < 110
kg/cm2 kg/cm2
17. Boiler Drum Level very High > 200 > 225
mm mm
18. Boiler Master Fuel Trip -- --
19. Overspeed Protection. -- 3300 Speed probe
rpm
20. Generator protection -- Class
A/B
21. Fire protection Activated -- Push Field Push Button
Button
22. Trip from ATRS -- -- Shutdown
Sequence.
23. TSLLE Device Lower than 7.5 % -- --