ABSTRACT
Methods used to evaluate the performance of protective coatings and their capability to predict
the service life in real environments are discussed in the context of the degradation process of a
coating system. The accelerated tests based on existing standards (ASTM) are compared with
some non-standardized methods such electrochemical impedance and electrochemical noise
methods. Fairly good qualitative correlation of accelerated test results with service
performance has been reported. It is noted that these "accelerated" tests may not really yield
results in an "accelerated" way as most methods require several thousands of hours of
exposure and the they are often destructive in nature. On the other hand, electrochemical
impedance and and electrochemical noise methods are non-destructive and non-accelerating in
nature yet they can produce quantitative or semi-quantitative results within a few days or even
hours. When real-life exposure tests are used in conjunction with the non-destructive
electrochemical impedance/noise methods, realistic models for life prediction of protective
coatings may be developed.
Introduction
Protective coatings is probably the most widely used method for combating corrosion. Steel
structures exposed to atmospheres, buried in the soil or immersed in the sea water are commonly
protected with coatings either alone or in combination with cathodic protection. This broad term -
"protective coatings" encompasses metallic coatings, inorganic coatings and organic coatings as
shown in Table 1.
No matter how complicated the design and formulation of a coating system may seem to be, its
protective properties all boil down to two basic functions:
Physical Barrier Function - to separate the metal from coming into contact with a corrosive
environment
Chemical Barrier Function - to control the micro-environment at the metal/coating interface
Any factors that may influence how the above two functions work will have an influence on the
protective property of a coating system (for better or for worse). Some of these factors are coating
selection, surface preparation, application condition, inspection and routine maintenance. When a
coating system failed prematurely, the coating's supplier, the contractor and the facility owner often
do not agree with each other over the causes of the coatings failure and who should pay for cost of
rectifying the problem. Sometimes lawsuits do arise from dispute of this nature. It was reported that
a coating system expected to last for 25 years failed only after 12 months in service [1]! While it is
possible to compare the relative salt spray resistance of different coating systems, there is no
straightforward answer to the simple question of how long the coating will last. It is hoped that this
paper will bring the coatings designers/specifiers, suppliers, contractors and facility owners a step
closer in the understanding of the pros and cons associated with various methods of coatings
evaluation and life prediction.
Table 2. Desirable Attributes for Methods of Coating Evaluation and Life Prediction
The first and most widely used accelerated test is the conventional salt spray (Fog) test which
carries the standard designations of ASTM B117, BS3900-Part12 and ISO 7253. Salt spray was first
used in 1914 for corrosion testing and was standardized by ASTM as test method B117 in 1939.
There have been many revisions with the latest designation being B117-97. As a
qualifying/acceptance test, it does provide RELATIVE corrosion resistance information for
coated/plated metals exposed to constant static condition of 5% NaCl at 35oC. There have been
many cases where the coated steel lasted thousands of hours in the salt spray tests but failed
prematurely in outdoor service (Fig.2) [8]. There are also cases where a coating system performed
well in outdoor exposure but failed quickly in the salt spray cabinet. It has long been recognized
that the coating's resistance to the salt spray environment can not be directly translated into the
resistance to other environmental conditions. In fact, it states very clearly in the ASTM standard
B117-97 that "prediction of performance in natural environments has seldom been correlated with
salt spray results when used as stand alone data". The natural environment is a dynamic and ever-
changing one. The cyclic wetting and drying when the rain comes and goes, the temperature
variation from day to night and the UV radiation from sunlight are all missing links in correlating
ASTM G85 Standard Practice for Modified Salt Spray (Fog) Testing
As an improvement to the original salt spray test, the modified salt spray (fog) testing (ASTM G85)
has introduced 5 modifications to the standard salt fog test:
Among these modifications, the dilute electrolyte cyclic fog dry test was reported to give better
correlation with outdoor exposure test. This procedure uses a much diluted electrolyte (0.05%
sodium chloride) with small amount (0.35%) of ammonium sulphate to represent industrial
atmospheres. The test cycle alternates between 1 hour of fog and 1 hour of dry-off. During each
drying-off cycle, the salt concentration would progressively increase thus exposing the samples to a
wider range of salt concentrations.
ASTM D5894-96 Practice for Cyclic Salt Fog/UV Exposure of Painted Metal
Extensive research work on the effect of condensation and UV radiation led to the incorporation of
UV radiation and condensation cycles into the cyclic salt spray test. The improved simulation of
natural atmospheric conditions is found in the ASTM D5894. Basically, the procedure involves the
following:
1 weeks (168 hours) fluorescent UV-condensation cycle as per ASTM G53 with 4 hours of UV
exposure at 60oC using UVA-340 fluorescent lamps and another 4 hours of condensation (pure
water) at 50oC
After 1 week, transfer the samples to a cyclic salt fog chamber and expose for another week as
Although this test is currently the most "realistic" laboratory test available for evaluating the coating
performance, there does not exist a magic conversion factor where X hours of laboratory exposure is
equivalent to Y years of actual weathering in service condition. If one considers the fact that the
duration for a full scale test requires over 4000 hours (about 6 months) and two sets of salt spray
equipment, not many companies may be able to justify the high cost and the long wait for running
such an "accelerated test". This is particularly true for in-house quality control/assurance
applications where rapid response to a process change is required.
Fig.3 Equivalent Circuit Model for a Metal Coated with Organic Polymeric Materials
where Rs is the electrolyte resistance, Rpore is the pore resistance in a coating system, Rt is the
charge transfer resistance, Cdl is the double layer capacitance at the metal/coating interface and Cc
is the coating capacitance.
Corrosion underneath a coating system can be described by the charge transfer resistance of Rt and
the double layer capacitance Cdl, while the coating performance can be described by the coating
capacitance and the pore resistance. With an increase in the permeability of a coating, the
conductive paths in the coating will increase and this will lead to the reduction in the pore
resistance. By measuring the changes in coating's capacitance, one can calculate the water-uptake
(by volume) in a coating system [2]:
Fig.4 [4] is the impedance spectra for a rubberized fibre coating applied on a properly prepared steel
surface. The pore resistance remained high even after 14 weeks immersion in 3.5% NaCl solution,
whereas for the same coating applied on the steel substrate with mill scales, a noticeable decrease in
the pore resistance is observed after 1 week immersion in NaCl solution (Fig.5).
.
Fig.4 The pore resistance remains high after 15 weeks immersion in 3.5% NaCl solution
In general, when a coating system can maintain the impedance value above 109 Ohm.cm2 , corrosion
at the metal/coating interface should not be an issue. When the impedance value drops below 107
Ohms.cm2 , one should be concerned about the corrosion activity at the metal/coating interface. The
corrosion rate underneath the coating can be determined from Rt:
where k is the conversion factor and B is the proportionality constants determined by Tafel
polarisation.
In conjunction with the conventional salt spray test (ASTM B117), Kendig and co-workers came up
with a model to predict the time-to-failure (TTF) for a coating system [5]:
where dx/dt is the disbond rate measured using a tape pullback method and %v is the water-uptake
in volume. When there is no appreciable pullback observed, Kendig used a default value of 10-4
mm/hr.
In conjunction with ASTM D610 and D714 for visual evaluation of coating's performance after
immersion in sea water, electrochemical impedance spectroscopy was used to study the correlation
between the breakpoint frequency of a coating system and its performance in immersed condition for
Electrochemical Noise
Another electrochemical technique that has shown promise in coating's evaluation and life
prediction is the electrochemical noise. The fluctuations of current and potential for a given system
can be monitored simultaneously, leading to the potential or current or resistance noise methods.
When a coating start to deteriorate, the potential of the system tends to shift towards the
active/negative direction, eventually approaching the potential value of a bare steel. Mirroring the
potential changes, the current tends to increase with time for the low performance coating systems.
The noise resistance (Rn=Vn/In) for a good coating system was found to be above 1010 Ohms.cm2
upon immersion and decreases gradually to 109 Ohms.cm2 after 2000 hours testing. AC impedance
and electrochemical noise techniques were also successfully used to rank the performance of several
coatings systems (polyurethane, epoxy-polyamide and alkyds) after 12 month exposure to an
industrial atmospheric environment [7]. It was observed that the electrochemical measurements
after exterior exposures showed the same general trend as those generated by laboratory immersion
tests.
Concluding Remarks
The availability of various standardized and non-standardized test methods means that the search for
the magic conversion factor where X hours of test (accelerated or non-accelerated, in laboratory or
in field) can be extrapolated to Y years of service life is continuing. In many consulting projects, the
author is often asked to prove how long a particular coating system will last. It takes a lot of effort
to explain to the clients that no such test methods exist yet. The standardized ASTM methods are
accelerated tests which may require several thousand hours of continuous operation for a typical
coating system (ASTM D5894 requires more than 4000 hrs). These tests are all destructive in nature
and the test results are qualitative. In contrast, the electrochemical impedance and electrochemical
noise methods, though not standardized, can provide rapid and quantitative measurements of the
protective properties of a coating system. These measurements are non-destructive and non-
accelerating. It may be possible to find a magic conversion factor for life prediction if one monitors
the long-term electrochemical responses of coating system under exterior exposure condition. The
coatings designers/specifiers, suppliers, contractors and facility owners should consider the
REFERENCES:
1. E. D. Thomas and A. A. Webb, Journal of Protective Coatings and Linings, Feb. 2001
2. D. M. Brasher and A. H. Kingsbury, J. Appl. Chem., Feb., 1954, p62
3. J. Wolstenhole, Corrosion Science, Vol. 13, p521, 1973.
4. J. H. Qiu, Corrosion resistance of rubberised fibre coating, to be published
5. M. Kendig, S. Jeanjaquet, R. Brown and F. Thomas, J. Coatings Tech., Vol.68, p39, 1996
6. J. R. Scully, J. Electrochem. Soc., Vol.136, No.4, p979, 1989
7. C-T. Chen and B. S. Skerry, Corrosion, Vol.47, p598, 1991
8. J. H. Qiu, to be published