Sunteți pe pagina 1din 48

PM Machine

Demagnetization
Analysis due to
Fault Conditions

Scott Stanton
Ryan Magargle
Julius Saitz
ANSYS, Inc.

© 2009 ANSYS, Inc. All rights reserved. 1 ANSYS, Inc. Proprietary


Motivation

1. In many permanent magnet motors during


the startup condition, the incident field can
push the operating point the knee and thus
never allowing the magnet to fully recover.

2. The knee point can lie in either in the 2nd or


3rd quadrant

© 2009 ANSYS, Inc. All rights reserved. 2 ANSYS, Inc. Proprietary


Test Case

Linear High Permeable


Material: μr = 20,000
I

N Non-Linear Magnet

© 2009 ANSYS, Inc. All rights reserved. 3 ANSYS, Inc. Proprietary


Determine Demag Point #1 using I=I1
and Original B-H Curve

Br

© 2009 ANSYS, Inc. All rights reserved. 4 ANSYS, Inc. Proprietary


Determine Demag Point #1 using I=I1
and Original B-H Curve

Br

1 O

© 2009 ANSYS, Inc. All rights reserved. 5 ANSYS, Inc. Proprietary


Draw a Line from the Origin to Point #1

Br

1 O

© 2009 ANSYS, Inc. All rights reserved. 6 ANSYS, Inc. Proprietary


Determine Point #2: Intercept off
Original BH Curve in 3rd Quadrant

Br

1 O
2

© 2009 ANSYS, Inc. All rights reserved. 7 ANSYS, Inc. Proprietary


Determine New Remanent Point Br’
Parallel to Original B-H Curve Slope

Br
Parallel
Br′

1 O
2

© 2009 ANSYS, Inc. All rights reserved. 8 ANSYS, Inc. Proprietary


Solve again, using Br’ and
Calculate Point #3

Br

Br′

O
3

© 2009 ANSYS, Inc. All rights reserved. 9 ANSYS, Inc. Proprietary


Draw a Line from the Origin to Point #3

Br

Br′

O
3

© 2009 ANSYS, Inc. All rights reserved. 10 ANSYS, Inc. Proprietary


Determine Point #4 which is the
Intercept off Original BH Curve in 3rd
Quadrant

Br

Br′

O
3
4

© 2009 ANSYS, Inc. All rights reserved. 11 ANSYS, Inc. Proprietary


Determine New Remanent Point Br’’
Parallel to Original B-H Curve Slope

Br

Br′
Br′′

O
3
4

© 2009 ANSYS, Inc. All rights reserved. 12 ANSYS, Inc. Proprietary


Solve again, using new Br and
Calculate Point #5

Br

Br′′′

-920

© 2009 ANSYS, Inc. All rights reserved. 13 ANSYS, Inc. Proprietary


Determine Point #6 which is the
Intercept off Original BH Curve in 3rd
Quadrant

Br

Br′′′

5
6

-920

© 2009 ANSYS, Inc. All rights reserved. 14 ANSYS, Inc. Proprietary


Continue to Iterate Until the Solved
Point Lies on the Original B-H Curve
within an Acceptable Tolerance

Br

Br1

-920

© 2009 ANSYS, Inc. All rights reserved. 15 ANSYS, Inc. Proprietary


This process is done on an element-by-
element basis

Br
Br1
Br 2

Br 3

Br 4
Br 5
Bn

H r1 Hr2 Hr3 Hr4 H r5 Hr n O

-920

© 2009 ANSYS, Inc. All rights reserved. 16 ANSYS, Inc. Proprietary


Extend Nonlinear BH Curve Into
the 3rd Quadrant
MQP-B+ from Magnequench

Br

Br′
Working point

Hc′ after
demag

Demag point

© 2009 ANSYS, Inc. All rights reserved. 17 ANSYS, Inc. Proprietary


Test Case

Linear High Permeable


Material: μr = 20,000
I

N Non-Linear Magnet

© 2009 ANSYS, Inc. All rights reserved. 18 ANSYS, Inc. Proprietary


Non-linear definition into the 3rd
Quadrant: Maxwell V13

© 2009 ANSYS, Inc. All rights reserved. 19 ANSYS, Inc. Proprietary


Step 1: Analyze Design
with I = 0 amps

© 2009 ANSYS, Inc. All rights reserved. 20 ANSYS, Inc. Proprietary


Step 1: Analyze Design
with I = 0 amps

© 2009 ANSYS, Inc. All rights reserved. 21 ANSYS, Inc. Proprietary


Step 2: Compute
Demagnetization Points
Excitation is Starting Current

© 2009 ANSYS, Inc. All rights reserved. 22 ANSYS, Inc. Proprietary


By and Hy on Magnet

© 2009 ANSYS, Inc. All rights reserved. 23 ANSYS, Inc. Proprietary


By is Below the Knee
Point into the 3rd Quadrant

Expect to
recoil in this
range

© 2009 ANSYS, Inc. All rights reserved. 24 ANSYS, Inc. Proprietary


Step 3: Create a Dynamically
Linked Design

© 2009 ANSYS, Inc. All rights reserved. 25 ANSYS, Inc. Proprietary


Use the Same Mesh as the Source
Design: Don’t Refine the Mesh

© 2009 ANSYS, Inc. All rights reserved. 26 ANSYS, Inc. Proprietary


Reset Coil Current to Zero

© 2009 ANSYS, Inc. All rights reserved. 27 ANSYS, Inc. Proprietary


Magnetic Field and Flux Density
in Magnet

© 2009 ANSYS, Inc. All rights reserved. 28 ANSYS, Inc. Proprietary


Demag and Recoil Permeabilities

Recoil Operating Points

Demag Operating Points

© 2009 ANSYS, Inc. All rights reserved. 29 ANSYS, Inc. Proprietary


B-H Curve for Alnico 9

© 2009 ANSYS, Inc. All rights reserved. 30 ANSYS, Inc. Proprietary


Dynamic demagnetization

Current

Time

© 2009 ANSYS, Inc. All rights reserved. 31 ANSYS, Inc. Proprietary


BH curve at a point inside magnet

© 2009 ANSYS, Inc. All rights reserved. 32 ANSYS, Inc. Proprietary


Working with demagnetized
magnet

© 2009 ANSYS, Inc. All rights reserved. 33 ANSYS, Inc. Proprietary


Generator Fault Example

• 550 W PM generator
• 4 Pole
• 3 Phase, 50HZ AC
• Ceramic 8D PM
• Rated Speed,
Open-Circuit to
Short-Circuit Fault

© 2009 ANSYS, Inc. All rights reserved. 34 ANSYS, Inc. Proprietary


Magnet

• 2nd quadrant demagnetization (demag)


• Spatially dependent demag due to fault

Initial Radial Magnetization

© 2009 ANSYS, Inc. All rights reserved. 35 ANSYS, Inc. Proprietary


Short-Circuit Analysis

• Short circuit at 15.2ms: Phase A peak

Ansoft LLC 3D_EMF_save_demag Maxwell3DDesign2 ANSOFT

80.00
Ansoft LLC 3D_EMF_save_demag Maxwell3DDesign2 ANSOFT
Ansoft LLC BH_Data_Points_Initial_Demag Maxwell3DDesign2 ANSOFT

80.00 Curve Info 0.40


Ansoft LLC BH_Data_Points_Initial_Demag Maxwell3DDesign2 ANSOFT

InducedVoltage(PhaseA)
Curve Info
Setup1 : Transient
0.40
InducedVoltage(PhaseA)
InducedVoltage(PhaseB)
Setup1 : Transient
Setup1 : Transient 0.35
InducedVoltage(PhaseB)
0.35
InducedVoltage(PhaseC)
Setup1 : Transient
Setup1 : Transient
InducedVoltage(PhaseC)
Setup1 : Transient 0.30 Material BH Curve
30.00 0.30
30.00
0.25
Volts [V]

0.25

B [T]
Volts [V]

0.20

B [T]
0.20
0.15
-25.00 0.15
-25.00
0.10
0.10
0.05
0.05
Operating Point
0.00
-80.00 -3.00E+005
0.00 -2.00E+005 -1.00E+005 0.00E+000
0.00
-80.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 -3.00E+005 -2.00E+005H [A/m] -1.00E+005 0.00E+000
0.00 5.00 10.00 [ms]
15.00 Time20.00 25.00 30.00 35.00 40.00 H [A/m]
Time [ms]

Bus short for all phases

© 2009 ANSYS, Inc. All rights reserved. 36 ANSYS, Inc. Proprietary


Short-Circuit Analysis

• Subsequent use of the magnet results in


reduced performance

Ansoft LLC 3D_EMF_demaged Maxwell3DDesign3 ANSOFT

80.00
Ansoft LLC 3D_EMF_demaged Maxwell3DDesign3
Curve Info ANSOFT

80.00 InducedVoltage(PhaseA)
Curve Info
Setup1 : Transient
Ansoft LLC BH_Data_Points_Demag Maxwell3DDesign3 ANSOFT
InducedVoltage(PhaseA)
InducedVoltage(PhaseB)
Setup1 : Transient
0.40
Ansoft LLC BH_Data_Points_Demag Maxwell3DDesign3 ANSOFT

Setup1 : Transient
InducedVoltage(PhaseB) 0.40
InducedVoltage(PhaseC)
Setup1 : Transient
Setup1 : Transient
InducedVoltage(PhaseC) 0.35
Setup1 : Transient 0.35
30.00 0.30
30.00 0.30
Volts [V]

0.25
Volts [V]

0.25

B [T]
0.20

B [T]
0.20
-25.00 0.15
-25.00 0.15
0.10
0.10
0.05
0.05
0.00 Operating Points
-80.00 -3.00E+005
0.00 -2.00E+005 -1.00E+005 0.00E+000
0.00
-80.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 -3.00E+005 -2.00E+005H [A/m] -1.00E+005 0.00E+000
0.00 5.00 10.00 15.00 Time20.00
[ms] 25.00 30.00 35.00 40.00 H [A/m]
Time [ms]

Weak Back EMF Addt’l short for all phases


© 2009 ANSYS, Inc. All rights reserved. 37 ANSYS, Inc. Proprietary
Short-Circuit Analysis

• Leading edge is weakened significantly


Ansoft LLC 3D_EMF_save_demag Maxwell3DDesign2 ANSOFT

80.00
Ansoft LLC 3D_EMF_save_demag Maxwell3DDesign2 ANSOFT

80.00

Original 30.00
30.00

Volts [V]
Volts [V]
-25.00
-25.00

-80.00
0.00
-80.00 5.00 10.00 15.00
0.00 5.00 Time [ms] 10.00 15.00
Time [ms]

Ansoft LLC 3D_EMF_demaged Maxwell3DDesign3 ANSOFT

80.00
Ansoft LLC 3D_EMF_demaged Maxwell3DDesign3 ANSOFT

80.00

Fault 30.00
30.00
Volts [V]
Volts [V]

-25.00
-25.00

-80.00
0.00
-80.00 5.00 10.00 15.00
0.00 5.00 Time [ms] 10.00 15.00
Time [ms]
© 2009 ANSYS, Inc. All rights reserved. 38 ANSYS, Inc. Proprietary
Conclusion

• To account for non-linear permanent magnets


in your designs, the ability to accurately
calculate the demagnetization point can be
critical.

• It has been shown that Maxwell® 3D


accurately accounts for this effect.

© 2009 ANSYS, Inc. All rights reserved. 39 ANSYS, Inc. Proprietary


Extend Nonlinear BH Curve Into
the 3rd Quadrant
MQP-B+ from Magnequench

Br

© 2009 ANSYS, Inc. All rights reserved. 40 ANSYS, Inc. Proprietary


Determine Working Point #1 using
I=I1 and Original B-H Curve
MQP-B+ from Magnequench

Br

Working point

© 2009 ANSYS, Inc. All rights reserved. 41 ANSYS, Inc. Proprietary


Freeze mur in Each Element,
Set I=0 to Determine No-Load Point
MQP-B+ from Magnequench

Br

Working point

© 2009 ANSYS, Inc. All rights reserved. 42 ANSYS, Inc. Proprietary


Determine Magnet Load Line at
I=0 amps
MQP-B+ from Magnequench

Load line without Br


other sources

Working point

© 2009 ANSYS, Inc. All rights reserved. 43 ANSYS, Inc. Proprietary


Determine Magnet Load Line for
the Working Point
MQP-B+ from Magnequench

Load line without Br


other sources

Working point

Load line with


other sources

© 2009 ANSYS, Inc. All rights reserved. 44 ANSYS, Inc. Proprietary


Determine Demag Point
MQP-B+ from Magnequench

Load line without Br


other sources

Working point

Demag point Load line with


other sources

© 2009 ANSYS, Inc. All rights reserved. 45 ANSYS, Inc. Proprietary


Determine New Remanent Point
Br’and Coercive Point Hc’
MQP-B+ from Magnequench

Load line without Br


other sources
Br′
Working point

Hc′ after
demag

Demag point Load line with


other sources

© 2009 ANSYS, Inc. All rights reserved. 46 ANSYS, Inc. Proprietary


Extend Nonlinear BH Curve Into
the 3rd Quadrant
MQP-B+ from Magnequench

Load line without Br


other sources
Br′
Working point

Hc′ after
demag

Demag point Load line with


other sources

© 2009 ANSYS, Inc. All rights reserved. 47 ANSYS, Inc. Proprietary


Add Magnetization Capability

• Based on the original


non-remanent B-H B Line a
curve
• Construct line b at the Br p
Line b
operating point p, which
is parallel to the line a
• Br is the intersection of
line b with B-axis
0 H
• Element by element

© 2009 ANSYS, Inc. All rights reserved. 48 ANSYS, Inc. Proprietary

S-ar putea să vă placă și