DUBAI INVESTMENTS PARK

THE GREEN COMMUNITY - PHASE 1


SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUBSTRUCTURE

Excavate in any material including planking and


strutting, dewatering etc.

A Trench excavation (ground beams) 10 m3

B Pit excavation (footings and necks) 120 m3

C Excavation in thickening to ground bed 4 m3

Backfilling with approved material, compact and well


rammed as per specification

D Foundation trench and column pits 62 m3

Filling including leveling and compacting to makeup


levels with selected excavated materials complete as
specified and as directed by the Engineer

E Filling under ground bed 56 m3

Disposal of excavated material away from site as


directed by the Engineer

F Remove excavated material 12 m3

Mass concrete using moderate sulphate resisting


cement, mix class 14/20

G In blinding, 50mm thick 263 m2

H In blinding, 100mm thick 110 m2

Antitermite Treatment

J Allow for antitermite treatment as pecified Item

Dewatering

K Allow for dewatering as specified Item

Rev-1
31/3/01 Carried to Collection
3/1 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUBSTRUCTURE [cont'd]

Reinforced concrete using moderate sulphate


resisting cement, mix class 32/20

A In foundations 40 m3

B In column necks 3 m3

C In wall necks 1 m3

D In ground beams 10 m3

E In ground bed, 100mm thick 25 m3

F In thickening to ground bed 1 m3

Steel bar reinforcement in any diameter

G In foundation 2,920 Kg

H In column necks 806 Kg

J In wall necks 137 Kg

K In ground beams 2,212 Kg

L In ground bed and thickening to ground bed 1,067 Kg

Rev-1
31/3/01 Carried to Collection

3/2 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUBSTRUCTURE [cont'd]

Sawn Formwork

A To vertical sides of foundation 72 m2

B Ditto, column necks 20 m2

C Ditto, circular column necks 13 m2

D Ditto, wall necks 14 m2

E Ditto, ground beams 101 m2

F Ditto to edge of slab and thickenings 2 m2

Rev-1
31/3/01 Carried to Collection

3/3 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 1

From page 3 / 2

From page 3 / 3

TOTAL - SUBSTRUCTURE
Carried to Summary

3/4 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUPERSTRUCTURE

Reinforced concrete using ordinary portland cement,


mix class 32/20

A In columns 26 m3

B In suspended slab, 200mm thick 47 m3

C In suspended slab, 100mm thick 1 m3

D In walls, 200mm thick 7 m3

E In beams 8 m3

F In steps and staircases 2 m3

G In landing 1 m3

H In staircase balustrade wall, 100mm thick 1 m3

J Ditto, 300mm thick 3 m3

K In upstand 2 m3

Reinforced concrete using ordinary portland cement


with inorganic copolymer liquid admixture, mix class
32/20

L In roof slab, 150mm thick 43 m3

M In beam 3 m

Bar reinforcement in any diameter

N In columns 4,628 Kg

P In suspended slabs 6,110 Kg

Q In walls 532 Kg

R In beams 2,200 Kg
Rev-1
31/3/01 Carried to Collection

3/5 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUPERSTRUCTURE [cont'd]

Bar reinforcement in any diameter [cont'd]

A In staircases 172 Kg

B In staircase balustrade wall 25 Kg

C In roof slab 5,945 Kg

D In upstand 550 Kg

Sawn Formwork

E To vertical sides of columns 282 m2

F To horizontal soffits of suspended slabs 219 m2

G To vertical edges of suspended slabs, 200mm thick 71 m

H To vertical sides of walls 60 m2

J To sides and soffits of beams 112 m2

K To sides and soffits of staircase 14 m2

L To horizontal soffits of landings 2 m2

M To vertical sides of balustrade walls 16 m2

N To sloping soffits of roof slabs 283 m2

P To vertical edges of roof slabs, 150mm thick 72 m

Q To vertical sides of upstand 13 m2

Reinforced concrete using ordinary portland cement,


mix class 32/20 including all necessary formwork
and reinforcement

R In lintels 200 x 200mm 74 m

S In lintels 150 x 200mm 5 m

T In lintels 100 x 200mm 18 m

U In jambs around opening as shown on drawing A-


202 31 m

V In concrete sill at opening as shown on drawing


A-202 2 m

Rev-1
31/3/01 Carried to Collection

3/6 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 5

From page 3 / 6

TOTAL - SUPERSTRUCTURE
Carried to Summary

3/7 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

BLOCKWORK

Hollow blockwork in cement and sand mortar as


specified including all ties

A Walls, 200mm thick 184 m2

B Ditto, 150mm thick 67 m2

C Ditto, 100mm thick 160 m2

Light weight pumice stone hollow blocks in cement


and sand mortar as specified including all ties

D Walls, 200mm thick 356 m2

E Ditto, 100mm thick 6 m2

Rev-1 TOTAL - BLOCKWORK


31/3/01 Carried to Summary

3/8 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ROOFING AND WATERPROOFING

ROOFING TYPE R1 (INSULATED)

A Minimum 1.5mm thick waterproofing membrane as


specified, liquid applied on pitched roof slab 290 m2

B 50mm thick expanded polystyrene insulation board


as specified on pitched roof over waterproofing
membrane (measured separately) 290 m2

C Supply only Barrel unglazed rustic natural coloured


clay roofing tiles as specified including two layers of
timber battens laid on pitched roof over insulation
board (measured separately) 290 m2

D Extra over ditto for ridge and hip tiles 58 m

E Extra over ditto for valley tiles 15 m

F Extra over ditto for verge 12 m

G Extra over ditto for eave 65 m

H Fix only Barrel unglazed rustic natural coloured clay


roofing tiles as specified fixed on timber battens laid
on pitched roof over insulation board (measured
separately) 290 m2

J Extra over ditto for ridge and hip tiles 58 m

K Extra over ditto for valley tiles 15 m

L Extra over ditto for verge 12 m

M Extra over ditto for eave 65 m

N Waterproofing skirting including waterproofing


membrane fashing etc. as specified 16 m

Carried to Collection

3/9 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ROOFING AND WATERPROOFING [cont'd]

WET AREA WATERPROOFING

A 2 components waterproofing membrane as specified


liquid applied to wet areas (Kitchens, Bath rooms
and balcony) 98 m2

B Ditto, for skirting 108 m

FOUNDATION WATERPROOFING

Protection of foundation by applying 3 coats of


approved bituminous compound as specified in
particular specification

C To under side of foundation 119 m2

D Ditto of ground beams 19 m2

E To vertical sides of foundation 74 m2

F Ditto of column necks 33 m2

G Ditto of wall necks 14 m2

H Ditto of ground beams 84 m2

J To top of foundation 92 m2

1500 gauge polythene vapour barrier

K Laid under ground bed 225 m2

Rev-1
31/3/01 Carried to Collection

3 / 10 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 9

From page 3 / 10

TOTAL - ROOFING AND WATERPROOFING


Carried to Summary

3 / 11 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

METAL WORK

PROVISIONAL SUM

A Allow provisional sum for supply and fix balcony


railing and balustrade Sum 11,600.00

B Overhead and profit for ditto %

C Assistance and attendance for ditto Sum

D Builder's work in connection for ditto Sum

TOTAL - METAL WORK


Carried to Summary

3 / 12 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

DOORS AND WINDOWS

Subframe for doors as shown on drawings including


fixing in position as specified

A Timber door type 1 1 No

B Ditto, type 2 2 No

C Ditto, type 3 2 No

D Ditto, type 4 7 No

E Ditto, type 5 3 No

F Ditto, type 6 4 No

G Deleted

H Ditto, type 8 1 No

Fix only doors as shown on drawings including


ironmongery, door frames, architraves, etc., as
specified

J Timber door type 1 1 No

K Ditto, type 2 2 No

L Ditto, type 3 2 No

M Ditto, type 4 7 No

N Ditto, type 5 3 No

P Ditto, type 6 4 No

Q Deleted

R Ditto, type 8 1 No

Rev-1
31/3/01 Carried to Collection

3 / 13 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

DOORS AND WINDOWS

PROVISIONAL SUM

A Allow provisional sum for supply of timber door Sum 36,200.00

B Overhead and profit for ditto %

C Allow provisional sum for supply of timber door


ironmongery Sum 62,500.00

D Overhead and profit for ditto %

E Allow provisional sum for supply and fix of aluminium


framed doors, windows and screens Sum 35,000.00

F Overhead and profit for ditto %

G Assistance and attendance for ditto Sum

H Builder's work in connection for ditto Sum

Demountable type access panel fabricated with


cement board on metal structure to receive final
finish (measured separately) including fixing in
position, ironmongery and the like all as shown
on drawings

J Panel size 600 x 800mm 6 No

Rev-1
31/3/01 Carried to Collection

3 / 14 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 13

From page 3 / 13

From page 3 / 14

TOTAL - DOORS AND WINDOWS


Carried to Summary

3 / 15 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

CARPENTRY AND JOINERY

PROVISIONAL SUM

A Allow provisional sum for supply and fix wardrobes Sum 19,000.00

B Overhead and profit for ditto %

C Assistance and attendance for ditto Sum

D Builder's work in connection for ditto Sum

E Allow provisional sum for supply and fix kitchen


cabinet with sink Sum 17,500.00

F Overhead and profit for ditto %

G Assistance and attendance for ditto Sum

H Builder's work in connection for ditto Sum

J Allow provisional sum for supply and fix kitchen


appliances Sum 6,700.00

K Overhead and profit for ditto %

L Assistance and attendance for ditto Sum

M Builder's work in connection for ditto Sum

TOTAL - CARPENTRY AND JOINERY


Carried to Summary

3 / 16 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES

INTERNAL

Floor finishes

A Preparation of concrete surfaces to receive paint


finish, Ref. F6 3 m2

B Coloured non-slip ceramic floor tiles, on and


including cement and sand mortar bed, grouting and
pointing up joints, size 200 x 200mm (Allow PC rate
Dhs. 25 / m² for supply), Ref. F2a 6 m2

C Ditto, size 200 x 200mm (Allow PC rate Dhs. 30/m²


for supply), ref. F2b 75 m2

D Ditto, size 300 x 300mm (Allow PC rate Dhs. 35/m²


for supply), ref. F2c 120 m2

E 20mm thick Natural marble floor tiles, with


penetrative protective sealant on and including
mortar bed, grouting and pointing up joints, Size 300
x 600mm (Allow PC rate 160/m² for supply), Ref. F4
163 m2

F 30mm thick natural marble tread with ditto, 300mm


wide (Allow PC rate Dhs. 140/m for supply), Ref. F4 10 m

G Ditto, average 300mm wide (Allow PC rate Dhs.


140/m for supply), Ref F4 11 m

H 20mm thick natural marble risers with ditto, 160mm


high (Allow PC rate Dhs. 150/m for supply), Ref. F4 21 m

Rev-1
31/3/01 Carried to Collection

3 / 17 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

INTERNAL [cont'd]

Threshold

A 30mm thick Natural marble threshold with exposed


edges pencil rounded including penetrative
protective sealant, 100mm wide; (Allow PC rate Dhs.
150/m² for supply) 4 m

B Ditto, 150mm wide (Allow PC rate Dhs. 150/m² for


supply) 1 m

C Ditto, 200mm wide (Allow PC rate Dhs. 150/m² for


supply) 5 m

Skirtings

D 100mm high Ceramic skirting on and including


backing, grouting and pointing up joints, to match
flooring type F2a (Allow PC rate Dhs. 3/m for
supply), ref S2a 14 m

E Ditto to match floor type F2b (Allow PC rate Dhs.4/m


for supply), ref. S2b 9 m

F Ditto to match floor type F2c (Allow PC rate Dhs. 4/m


for supply), ref. S2c 87 m

G 100mm high natural marble skirting on and including


backing, grouting, and pointing up joints, to match
flooring F4 (Allow PC rate Dhs. 35/m for supply), Ref
S1 108 m

Rev-1
31/3/01 Carried to Collection

3 / 18 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

INTERNAL [cont'd]

Wall finishes

A 15mm thick cement sand smooth finish plaster as


specified to concrete or block surfaces to receive
paint finish including angle beads, stop beads
etc.Ref. W3, W4 and W5 750 m2

B Ceramic glazed wall tiles on and including backing,


grouting and pointing up joints, size 200 x 100mm
(Allow PC rate Dhs. 30/m² for supply), Ref. W2b 175 m

C Ditto, but fixed on demountable access panel 2 m2

Ceiling finishes

D 10mm thick cement sand smooth finish plaster as


specified to concrete soffits to receive paint finish,
Ref. C3 and C4 45 m2

E Ditto, but sloping soffits 53 m2

F Decorative gypsum board suspended ceiling as


specified including concealed galvanized steel
suspension system (paint measured separately),
Ref. C5 161 m2

G Ditto, but bulkhead at Entrance hall 16 m

H Ditto, but bulkhead at Entrance lobby 5 m

J Ditto, but bulkhead at Dining room 12 m

K Ditto, but bulkhead at Living room 14 m

L Ditto, but bulkhead at Salon 16 m

M Ditto, but bulkhead at Family room 15 m

N Spray plaster as specified to soffit of slab, Ref.


C7 1 m2
Rev-1
31/3/01 Carried to Collection

3 / 19 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

INTERNAL [cont'd]

Ceiling finishes [cont'd]

A Decorative gypsum tiles 600 x 600mm suspended


ceiling as specified including semi exposed
suspension system (paint measured separately),
Ref. C8 14 m2

B Calcium silicate tiles 600 x 600mm fully accessible


suspended ceiling in exposed aluminium grids as
specified including suspension system (paint
measured separately), Ref. C2
101 m2

C Ditto in bulkhead as shown on detail 6 drawing A-


203 15 m

Rev-1
31/3/01 Carried to Collection

3 / 20 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

EXTERNAL

Floor finishes

A Coloured non slip ceramic floor tiles, on and


including mortar bed, grouting and pointing up joints,
size 300 x 300mm (Allow PC rate Dhs. 80/m² for
supply), Ref. F2d 45 m2

B 20mm thick natural granite slab, with penetrative


protective sealant on and including mortar bed,
grouting and pointing up joints, size 300 x 600mm
(Allow PC rate Dhs. 200/m² for supply), Ref. F5 12 m2

C 30mm thick natural granite tread with ditto, 300mm


wide (Allow PC rte Dhs. 175/m for supply), Ref F5 3 m

D 20mm thick natural granite riser, with ditto, 165mm


high (Allow PC rate Dhs. 150/m for supply), Ref. F5 3 m

Skirting

E 100mm high ceramic skirting on and including


backing, grouting, jointing and pointing up
joints, to match flooring type F2d (Allow PC rate
Dhs. 8/m for supply), Ref. S2d 32 m

Wall finishes

F 20mm thick external plaster as specified to


concrete or block surfaces including angle
beads, stop beads etc., to receive paint finish,
Ref. EW 86 m2

G Ditto, but in columns 23 m2

H Ditto, but in projection around window type 2,


size 1500 x 2100mm 2 No

J Ditto, but in projection around window type 10,


size 1500 x 2000mm 3 No

K Ditto, but in projection around window type 11,


size 1500 x 1250mm 1 No
Rev-1
31/3/01 Carried to Collection

3 / 21 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

EXTERNAL [cont'd]

Wall finishes [cont'd]

A 20mm thick cement sand plaster with silicate based


coloured fine-grained contains as specified to
concrete or block surfaces including angle beads,
stop beads etc., Ref EW2 443 m2
B Ditto, but as demountable access panel 1 m2
C Deleted

D Deleted
E Deleted
F Ditto, but in projection around window type 2a, size
1500 x 2000mm 2 No

G Deleted

H Deleted

L 20mm thick cement sand plaster with silicate based


coloured fine-grained contains as specified to
concrete or block surfaces including angle beads,
stop beads etc., Ref. EW2 in projection around
window type 10, size 1500 x 2000mm 3 No
M Deleted

N Architectural decorative moulding as shown on


drawing A210 including painting as specified, Ref.
EW1 at 1st floor level as shown in drawing A210 64 m

P Ditto, but in column head as shown on the


drawing A213 9 No

Q Ditto, but in column plinth ditto 9 No

R Ditto at windows 8 No

S Ditto at gable ends 2 No

T Ditto above entrance door type 1 1 No

U Ditto, around window type 9, size 600 x 600mm 7 No

Rev-1
31/3/01 Carried to Collection

3 / 22 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

FINISHES [cont'd]

EXTERNAL [cont'd]

Wall finishes [cont'd]

A Decorative GRC elements as specified and as


shown on drawings including decoration and
fixing in place, Ref. EW7 to balcony wall coping 8 m

B Ditto to balcony column top 5 No

C 20 x 20 aluminium chanel in plaster, Ref. EW6 72 m

Ceiling finishes

D 100mm wide linear aluminium suspended ceiling


with wooden finish effect as specified including
suspension system, Ref. C6 52 m2

Rev-1
31/3/01 Carried to Collection

COLLECTION

From page 3 / 17

From page 3 / 18

From page 3 / 19

From page 3 / 20

From page 3 / 21

From page 3 / 22

From page 3 / 23

Rev-1 TOTAL - FINISHES


31/3/01 Carried to Summary

3 / 23 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

PAINTING AND DECORATION

INTERNAL

Prepare and apply acrylic base emulsion paint matt


finish as specified

A To plastered walls, Ref. W3 736 m2

B To plastered soffits of slabs, Ref. C3 42 m2

C To plastered sloping soffits of slabs, Ref. C3 53 m2

D To gypsum board suspended ceilings, Ref. C5 161 m2

E Ditto, but bulkhead at Entrance hall 16 m

F Ditto, but bulkhead at Entrance lobby 5 m

G Ditto, but bulkhead at Dining room 12 m

H Ditto, but bulkhead at Living room 14 m

J Ditto, but bulkhead at Salon 16 m

K Ditto, but bulkhead at Family room 15 m

Prepare and apply cement based paint as


specified

L To plaster walls, Ref. W5 6 m2

Rev-1
31/3/01 Carried to Collection

3 / 24 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

PAINTING AND DECORATION [cont'd]

INTERNAL [cont'd]

Prepare and apply synthetic enamel paint matt finish


as specified

A To smooth finished floor, Ref. F6 3 m2

B To plastered walls, ref. W4 7 m2

C To plastered soffits of slabs, ref. C4 3 m2

D To calcium silicate tile ceiling, Ref. C2 101 m2

E Ditto in bulk head as shown on detail 6, drawing


A-203 15 m

EXTERNAL

Prepare and apply Amphisilan Silicon resin paint


as specified

E To plaster walls, Ref. EW 86 m2

F Ditto, but in columns, Ref. EW 23 m2

G To window projection around type 2, size 1500 x


2100mm, Ref. EW 2 No

H Ditto, type 10, size 1500 x 2000mm, Ref. EW 3 No

J Ditto, type 11, size 1500 x 1250mm, Ref. EW 1 No

Rev-1
31/3/01 Carried to Collection

3 / 25 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 24

From page 3 / 25

TOTAL - PAINTING AND DECORATION


Carried to Summary

3 / 26 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SANITARY FITTINGS AND FIXTURES

Fix only the following sanitary fixtures and fittings


including taps, flexible connectors, valves, etc., fixing
in position, connecting to water supply and waste as
detailed on specification

Toilet

A Wash hand basin fixed to counter top 1 No

B Water closet with matching cistern 1 No

Guest Toilet

C Wash hand basin fixed to counter top 1 No

D Water closet with matching cistern 1 No

E Bidet 1 No

F Shower tray 1 No

Bathroom

G Wash hand basin fixed to counter top 3 No

H Water closet with matching cistern 3 No

J Bidet 3 No

K Shower tray 2 No

L Bath tub 1 No

Carried to Collection

3 / 27 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SANITARY FITTINGS AND FIXTURES [Cont'd]

Fix only the following sanitary fixtures and fittings


including taps, flexible connectors, valves, etc., fixing
in position, connecting to water supply and waste as
detailed on specification [cont'd]

Master bath

A Wash hand basin fixed to counter top 2 No

B Water closet with matching cistern 1 No

C Bidet 1 No

D Shower tray with shower cubical 1 No

E Jacuzzi 1 No

Fix only the following sanitary accessories as


specified

F For toilet 1 No

G For guest toilet 1 No

H For bathrooms 2 No

J For Master Bath 1 No

Carried to Collection

3 / 28 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SANITARY FITTINGS AND FIXTURES [Cont'd]

Provisional Sum

A Allow provisional sum for supply and fix vanity top Sum 17,000.00

B Overhead and profit for ditto %

C Assistance and attendance for ditto Sum

D Builder's work in connection for ditto Sum

E Allow provisional sum for supply of sanitary fixtures,


fitting and accessories Sum 15,000.00

F Overhead and profit for ditto %

G Allow provisional sum for supply and fix of Jacuzzi Sum 5,000.00

H Overhead and profit for ditto %

Carried to Collection

3 / 29 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 27

From page 3 / 28

From page 3 / 29

TOTAL - SANITARY FITTINGS AND FIXTURES


Carried to Summary

3 / 30 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

EXTERNAL WORKS

PROVISIONAL SUM

A Allow provisional sum for boundary wall to Family


Villa Sum 83,000.00

B Allow provisional sum for Hard and Soft Landscaping


Works Sum 70,000.00

C Overhead and profit for ditto %

D Assistance and attendance for ditto Sum

E Builder's work in connection for ditto Sum

TOTAL - EXTERNAL WORKS


Carried to Summary
3 / 31 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION

HVAC INSTALLATION

Note :

All controls and associated Electrical


Installations, appurtenances, valves, strainers
etc., in connection with the Mechanical
equipment as specified and detailed on drawing
Nos.M-03 FV-AC-01 to FV-AC-04 are deemed to
be included within the item Unit Rate

EQUIPMENTS

Supply and Install the following HVAC equipment


complete as specified and as shown on the drawings
to give a complete system that is acceptable to the
Engineer and all Local Authorities and under the
following sections

Fan Coil Units

Fan coil units, including combination room


thermostat and manual three speed LO-ME-HI motor
control switches, valves, strainers, flange/union,
complete as specified in specification for Plumbing
and Mechanical Installation Section 1207-G and as
detailed on drawing Nos. M-03, FV-AC-01 and FV-
AC-02

A Ref. FCU - 1, ducted unit 1 No

B Ref. FCU - 2, ditto 3 No

C Ref. FCU - 3, ditto 1 No

D Ref. FCU - 4, ditto 1 No

E Ref. FCU - 5, ditto 1 No

F Ref. FCU - 6, ditto 1 No.

G Ref. FCU - 7, ditto 1 No

H Ref. FCU - 8, ditto 1 No

Carried to Collection

3 / 32 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

Fans

Supply and install the following exhaust fans


complete as specified in specification for Plumbing
and Mechanical Installation Section 1207 H3

A Ref. EXF - 350 CFM 1 No.

Silencers as specified

B Allow for duct silencers as required Item

DUCT WORK

Rectangular ductwork including G-90 zinc coating


complete with all necessary bracing and supports,
access openings, dampers, volume control
dampers measured separately vanes, fixing
accessories, fittings, bends, reducers, all as
specified in specification for Plumbing and
Mechanical Installation Section 1207 J, 1207 P and
as shown on the drawing No. M-03

C Supply air ducts 576 Kg

D Fresh air ducts 121 Kg

E Exhaust air ducts 103 Kg

F Return air ducts 211 Kg

G Flexible ducts 6" diameter 6 No

H Flexible ducts 8" diameter 8 No


Flexible connections as specified in specification for
Plumbing and Mechanical Installation Section 1207-
M

J To FCU's and exhaust fans Item

Carried to Collection

3 / 33 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

DAMPERS

Volume dampers, as specified in specification for


Plumbing and Mechanical Installation section 1207-J
4

A To duct size 4" x 4" 3 No

B To duct size 6" x 4" 2 No

C To duct size 8" x 6" 2 No

D To duct size 10" x 6" 2 No

E To duct size 12" x 8" 1 No

Gravity dampers as specified in Specification for


Plumbing and Mechanical Installation Section 1207
Q8

F To duct size 6" x 4" 2 No

G To duct size 6" x 6" 1 No

H To duct size 8" x 6" 1 No

AIR DISTRIBUTION OUTLETS


Air distribution outlets as specified in specification for
Plumbing and Mechanical Installation Section 1207-
Q

Supply Ceiling Diffusers.

J Type SCD, size 6" X 6" 4 No

K Type SCD, size 9" x 9" 2 No

L Type SCD, size 12" x 12" 4 No


Rev-1
31/3/01 Carried to Collection

3 / 34 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

AIR DISTRIBUTION OUTLETS [cont'd]

Air distribution outlets as specified in specification for


Plumbing and Mechanical Installation Section 1207-
Q [cont'd]

Supply Linear Diffusers

A Type SLBD, 2" width - ½" spacing 1/8" Bar 15


Deflection, 2 ft 7 No

B Ditto, 3.3 ft 1 No

C Ditto, 3.5 ft 1 No

D Ditto, 5.0 ft 3 No

E Ditto, 8.0 ft 1 No

F Type SLBD, 2" width - 1/4" spacing 1/8" Bar 15


Deflection, 2 ft 2 No

Return Ceiling Diffusers

G Type RCD, size 6" x 6" 1 No

H Type RCD, size 9" x 9" 2 No

J Type RCD, size 12" x 12" 3 No

Exhaust Ceiling Diffusers

K Type ECD, size 6" x 6" 5 No

Rev-1
31/3/01 Carried to Collection

3 / 35 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

AIR DISTRIBUTION OUTLETS [cont'd]

Air distribution outlets as specified in specification for


Plumbing and Mechanical Installation Section 1207-
Q [cont'd]

Fresh Air Louver

A Type FAL, size 16" x 4" 1 No

B Type FAL, size 18" x 12" 1 No

C Type FAL, size 10" x 6" 2 No

D Type FAL, size 16" x 10" 1 No

Return Air Grille

E Type RAG, size 18" x 8" 1 No

F Type RAG, size 24" x 8" 5 No

Return Linear Diffusers

G 2" width ½" spacing, 1/8" Bar 15 Deflection - 2 ft 5 No

H Ditto, 2.5 ft 4 No

J Ditto, 3.3 ft 1 No

K Ditto, 17 ft 1 No

L 2" width 1/4" spacing, 1/8" Bar 15 Deflection - 2 ft


2 No

Rev-1
31/3/01 Carried to Collection

3 / 36 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

AIR DISTRIBUTION OUTLETS [cont'd]

Air distribution outlets as specified in specification for


Plumbing and Mechanical Installation Section 1207-
Q [cont'd]

Supply Air Registers

A Type SAR, size 18" x 8" 1 No

B Type SAR, size 24" x 8" 5 No

CHILLED WATER PIPE WORK

Chilled water pipe and fittings black mild steel


seamless type to BS 1387 complete with fittings,
fixing accessories, all as specified in specification for
Plumbing and Mechanical Installation Section 1210

3
C /4" diameter pipe 27 m

D 1" diameter pipe 8 m

E 1 1/4" diameter pipe 20 m

F 1 ½" diameter pipe 27 m

G 2" diameter pipe 13 m

Rev-1
31/3/01 Carried to Collection

3 / 37 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

CONDENSATE DRAIN

uPVC - Type 1 condensate drain pipes including


fittings, accessories complete all as specified in
specification for Plumbing and Mechanical
Installation Section - 1210

A 1" diameter pipe 21 m

INSULATION

Supply and install duct work insulation with vapour


barrier, mastic adhesives, etc., complete all as
specified in specification for Plumbing and
Mechanical Installation Section -1212 and drawing
No. M-03

B Supply air duct work 108 m2

C Fresh air duct work 25 m2

D Exhaust air duct work 21 m2

E Return air duct work 38 m2

Rev-1
31/3/01 Carried to Collection

3 / 38 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

INSULATION [cont'd]

Insulation on Chilled Water Pipe work with vapour


barrier, mastic adhesives, etc., all as specified in
specification for Plumbing and Mechanical
Installation Section -1212

3
A /4" diameter pipe 27 m

B 1" diameter pipe 8 m

C 1 1/4" diameter pipe 20 m

D 1 ½" diameter pipe 27 m

E 2" diameter pipe 13 m

Insulation on condensate drain pipe work as


specified in specification for Plumbing and
Mechanical Installation Section -1212

3
F /4" diameter pipe 21 m

Rev-1
31/3/01 Carried to Collection

3 / 39 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

Note: Alternate 1 for Master Bedroom rates and


extensions only and not to be carried to
Summary

Master Bed Room ALT - 1

Fan Coil Units

Fan coil units, including combination room


thermostat and manual three speed LO-ME-HI motor
control switches, valves, strainers, flange/union,
complete as specified in specification for Plumbing
and Mechanical Installation Section 1207-G and as
detailed on drawing Nos. M-03, FV-AC-01 and FV-
AC-02

A Ref. FCU - 5 1 No

B Ref. FCU - 7 1 No

DUCT WORK

Rectangular ductwork including G-90 zinc coating


complete with all necessary bracing and supports,
access doors, dampers, volume control dampers
measured separately vanes, fixing accessories,
fittings, bends, reducers, all as specified in
specification for Plumbing and Mechanical
Installation Section 1207 J, 1207 P and as shown on
the drawing No. M-03

C Supply air ducts 63 Kg

D Fresh air ducts 25 Kg

E Exhaust air ducts 24 Kg

F Return air ducts 28 Kg

Flexible connections as specified in specification for


Plumbing and Mechanical Installation Section 1207-
M

G To FCU's and exhaust fans Item

3 / 40 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)


Not to Carried to Collection

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

Note: Alternate 1 for Master Bedroom rates and


extensions only and not to be carried to
Summary

Master Bed Room ALT - 1 [cont'd]

DAMPERS

Volume dampers, as specified in specification for


Plumbing and Mechanical Installation section 1207-J
4
A To duct size 6" x 4" 1 No

B To duct size 8" x 6" 1 No

Gravity dampers as specified in Specification for


Plumbing and Mechanical Installation Section 1207
Q8

C To duct size 8" x 6" 1 No

AIR DISTRIBUTION OUTLETS


Air distribution outlets as specified in specification for
Plumbing and Mechanical Installation Section 1207-
Q

Supply Ceiling Diffusers.

D Type SCD, size 6" X 6" 2 No

Return Ceiling Diffusers

E Type RCD, size 6" x 6" 1 No

Exhaust Ceiling Diffusers

F Type ECD, size 6" x 6" 1 No

Not to Carried to Collection

3 / 41 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HVAC INSTALLATION [cont'd]

Note: Alternate 1 for Master Bedroom rates and


extensions only and not to be carried to
Summary

Master Bed Room ALT - 1 [cont'd]

Fresh Air Louver

A Type FAL, size 16" x 10" 1 No

Return Air Grille

B Type RAG, size 24" x 6" 1 No

Supply Air Registers

C Type SAR, size 24" x 6" 1 No

INSULATION

Supply and install duct work insulation with vapour


barrier, mastic adhesives, etc., complete all as
specified in specification for Plumbing and
Mechanical Installation Section -1212 and drawing
No. M-03

D Supply air duct work 11 m2

E Fresh air duct work 5 m2

F Exhaust air duct work 5 m2

G Return air duct work 4 m2

Not to Carried to Collection

3 / 42 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HOT AND COLD WATER INSTALLATION

Domestic cold water pipe work

uPVC pipes type2 to BS-3505 with spigot and socket


cemented type joints and fittings to BS 4346 Part 1
including necessary accessories insulation, fixing in
position, excavation bed and surround protection
slab, backfilling and remove surplus all as specified
in Plumbing and Mechanical Installation Section
1202 and 1210

A 1½" diameter pipe 8 m

B 11/4" diameter pipe 6 m

C 1" diameter pipe 6 m

D ¾" diameter pipe 67 m

Distribution pipes

uPVC pipes type - 2 to BS-3505 with spigot and


socket cemented type joints and fittings to BS 4346
Part 1 including necessary accessories, all as
specified in specification for Plumbing and
Mechanical Installation Section 1210

E 11/4" diameter pipe 12 m

F ¾" diameter pipe 10 m

Carried to Collection

3 / 43 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HOT AND COLD WATER INSTALLATION [cont'd]

Cross linked polyethylene pipes (XLPE) in and


including flexible protective conduits, fittings and
fixings complete as per specification for Plumbing
and Mechanical Installation Section 1210

A 1" diameter pipe 10 m

B ¾" diameter pipe 30 m

C ½" diameter pipe 61 m

Valves

Supply and fix following valves complete as per


specification for Plumbing and Mechanical
Installation Section 1210

D 1½" diameter isolating valve 2 No

E 11/4" ditto 2 No

F ¾" diameter - chrome plated valve 13 No

G ¾" diameter angle valve 6 No

H ½" diameter angle valve 42 No

Hose Bibbs

Chrome plated brass, compression type with chrome


plated handle and standard male hose connection
hose bibbs complete as per specification for
Plumbing and Mechanical Installation Section 1202
G6

J ¾" diameter hose bib tap 3 No

Carried to Collection

3 / 44 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

HOT AND COLD WATER INSTALLATION [cont'd]

Domestic Hot water pipe work and fittings

Pipework and fittings

Seamless copper tube to BS 2871, complete with all


necessary fitting to BS 864 Part-2, type A brass;
including insulation; all as per specification for
Plumbing and Mechanical Installation Section 1210
and 1212

A ¾" diameter pipe 28 m

B ½" diameter pipe 47 m

Water heater

Supply and install cylindrical storage type water


heaters constructed of heavy gauge steel white
enamel finish externally and glass lining from inside
polyurethane foam insulation, complete including all
necessary valves, thermometers and pipe and
flexible connections, drain pipes all as specified in
specification for Plumbing and Mechanical
Installation Section 1202 G780 and as shown on the
drawings

C Type EWH, 80 litre capacity 6 No


Water meter

D Disk positive displacement type water meters


furnished with straight reading dial complete with
valves, fittings and labels all as specified in
specification for Plumbing and Mechanical
Installation Section 1202 G-8 1 No
Stress analysis and water hammer

E Stress analysis on the water supply system including


any additional valves, surge tanks, bellows, all
complete as specified in specification for Plumbing
and Mechanical Installation Section 1202 C
Item

Carried to Collection

3 / 45 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM

Drainage and waste water pipe work

Note :
All pipes under building shall be protected by
concrete

Rain water

uPVC type - 1 to BS 5255 pipes including all


necessary fittings and accessories, clean outs etc
fixing in position all as specified in specification for
Plumbing and Mechanical Installation Section 1210

A 3" diameter balcony drain pipe 6 m

Waste Water

uPVC pipe type - 3 to BS 4660 including all


necessary fittings, accessories, cleanouts and
minimum 100mm thick concrete encasing, fixing in
position complete as specified in specification for
Plumbing and Mechanical Installation Section 1202B
and 1210

B 4" diameter 7 m

C 3" diameter 23 m

D 1½" diameter 5 m

E 11/4" diameter 4 m

uPVC pipe type - 1 to BS 5255 pipes including all


necessary fittings and accessories clean outs etc.
fixing in position all as specified in specification for
Plumbing and Mechanical Installation Section 1210

F 3" diameter pipe 45 m

G 1½" diameter -ditto- 34 m

H 11/4" diameter -ditto- 19 m

Rev-1
31/3/01 Carried to Collection

3 / 46 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM [cont'd]

Drainage and waste water pipe work [cont'd]

Sewage

uPVC pipe type - 3 to BS 4660 including all


necessary fittings, accessories, cleanouts and
minimum 100mm thick concrete encasing, fixing in
position complete as specified in specification for
Plumbing and Mechanical Installation Section 1202B
and 1210

A 4" diameter 33 m

uPVC pipe type - 1, to BS 4514 pipes including all


necessary fitting and accessories, clean outs etc.
fixing in position as specified in specification for
Plumbing and Mechanical Installation Section 1210

B 4" diameter 20 m

Vent Piping

uPVC pipe type - 1 to BS 5255 pipes including all


necessary fitting and accessories, clean outs etc.
fixing in position as specified in specification for
Plumbing and Mechanical Installation Section 1210

C 4" diameter vent pipe vertical laid in ducts and


extended 1500mm above roof level 20 m

D 3" diameter -ditto- 16 m

uPVC pipe type - 3 to BS 4660 including all


necessary fittings, accessories, cleanouts and
minimum 100mm thick concrete encasing, fixing in
position complete as specified in specification for
Plumbing and Mechanical Installation Section 1202B
and 1210

E 4" diameter 5 m
Rev-1
31/3/01 Carried to Collection

3 / 47 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM [cont'd]

Vent Piping [cont'd]

Vent caps

uPVC with open slots all around cowl vent caps


complete as specified in specification for Plumbing
and Mechanical Installation Section 1202 E-7

A For 4" diameter pipe 5 No

B For 3" diameter pipe 4 No

Balcony drain free discharge point complete as per


drawings and specifications

C 3" balcony drain free discharge 1 No

Balcony drains

D uPVC with large sump and integral flange and dome


type uPVC strainer balconey drain complete as
specified in specification for Plumbing and
Mechanical Installation Section 1202 E5 1 No

Floor drain

E uPVC floor drain with 70mm water seal complete as


specified in specification for Plumbing and
Mechanical Installation Section 1202 E2 7 No

Carried to Collection

3 / 48 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM [cont'd]

Traps complete as per drawings and specifications

A 'P' trap for WC 6 No

B 'P' trap for bidet 5 No

C Bottle trap for wash hand basin 7 No

D 'P' trap for bath tub 3 No

E 'P' trap for shower tray 2 No

F Bottle trap for sinks 1 No

Carried to Collection

3 / 49 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM [cont'd]

EXTERNAL

Waste Water

uPVC pipes type - 3 to BS 4660 including all


necessary fittings and accessories, cleanouts, fixing
in position, excavation, bed and surround protection
slab, backfilling and remove surplus all complete as
specified in Plumbing and Mechanical Installation
Section 1202 and 1210

A 6" diameter pipe 38 m

B 4" diameter pipe 4 m

C 1½" diameter sump pump line 16 m

Sewage

uPVC pipes type - 3 to BS 4660 including all


necessary fittings and accessories, cleanouts, fixing
in position, excavation, bed and surround protection
slab, backfilling and remove surplus all complete as
specified in Plumbing and Mechanical Installation
Section 1202 and 1210

D 6" diameter pipe 38 m

E 4" diameter pipe 3 m

Vent Pipes

uPVC pipes type - 3 to BS 4660 including all


necessary fittings and accessories, cleanouts, fixing
in position, excavation, bed and surround protection
slab, backfilling and remove surplus all complete as
specified in Plumbing and Mechanical Installation
Section 1202 and 1210

F 4" diameter pipe 6 m

Carried to Collection

3 / 50 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION [cont'd]

DRAINAGE SYSTEM [cont'd]

EXTERNAL [cont'd]

Gully trap

Heavy duty uPVC gully traps complete as specified


in specification for plumbing and mechanical
installation section 1202 E1

A 6" gully trap 1 No

Manhole

Manhole including all excavation, disposal of surplus


materials, blinding, reinforced concrete base, walls
and cover frame, GRP lining, benching, manhole
covers, with frames and the like complete as
specified in specification for Plumbing and
Mechanical Installation Section 1202 F4

B Dry manhole complete as detailed on drawing No.


FV-DR-01 2 No

C 2700 x 1200 x 1200mm deep manhole as detailed


on drawing No. MHD-1 1 No

Holding Tank

Holding tank complete as specified and shown in


drawing No. FV-DR-01

D Size 2700 x 1200 x 1200mm 1 No

Carried to Collection

3 / 51 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION[Cont'd]

GAS INSTALLATION

Copper LPG gas pipe including fittings and


accessories complete as specified

A ½" diameter pipe 5 m

Valves

B Supply and fix ½" cock valve 1 No

Rev-1
31/3/01 Carried to Collection

3 / 52 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION[Cont'd]

FIRE FIGHTING SYSTEM

Fire extinguishers complete as specified in


specification for Plumbing and Mechanical
Installation Section 1204

A 6 Kg ABC rating type fire extinguisher 1 No

Fire blanket

B Texturised woven glass fibre, fire blanket to BS


6575, impregnated both sides with a special high
temperature silicon rubber, 565 gm/m² approximate
finished weright complete as specified in
specification for Plumbing and Mechanical
Installation Section 1204 1 No

Carried to Collection

3 / 53 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

MECHANICAL INSTALLATION[Cont'd]

SUNDRIES

A Allow for DEWA charges including administration


and laison work by the Contractor Item

B Allow for supports, including fixings, anchors,


insulating block and anti vibration devices Item

C Allow for identification labels including plates, discs,


labels, charts and colour coding Item

D Allow for testing and commissioning including


operating completed installation and fuel and power
as specified Item

E Allow for providing tools and spares including

maintenance kit, loose keys and consumable stores. Item

F Documents including shop drawings, as built


drawings, operating instructions and maintenance
manuals as specified Item

G Allow for incidental work Item

H Allow for protective painting and decorative painting Item

J Allow for any additional items not included above but


necessary for the successful completion of the
Mechanical Installation Item

Carried to Collection

3 / 54 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 32
From page 3 / 33
From page 3 / 34
From page 3 / 35
From page 3 / 36
From page 3 / 37
From page 3 / 38
From page 3 / 39
From page 3 / 40 Not included
From page 3 / 41 Not included
From page 3 / 42 Not included
From page 3 / 43
From page 3 / 44
From page 3 / 45
From page 3 / 46
From page 3 / 47
From page 3 / 48
From page 3 / 49
From page 3 / 50
From page 3 / 51
From page 3 / 52
From page 3 / 53
From page 3 / 54

TOTAL - MECHANICAL INSTALLATION


Carried to Summary DHS.

3 / 55 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION

LIGHTING AND POWER INSTALLATION

Distribution Boards

Supply and install the following Distribution Boards


complete as specified and as shown on the drawings

Main Distribution Board

A Ref. MDB-GFV 1 No

Distribution Boards

B Ref. DB-GFV 1 No

C Ref. DB-FFV 1 No

Electricity Meter

D Supply, install and complete cabinet with meter as


specified and detailed on drawing (meter supplied by
DEWA) 1 No

Feeder cables

E MDB-GFV
4 x 35mm2 XLPE ARM + 16mm2 ECC 1 No

F DB-GFV
4 x 25mm2 + 16mm2 ECC 1 No

G DB-FFV
4 x 16mm2 + 16mm2 ECC 1 No

Carried to Collection

3 / 56 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

LIGHTING AND POWER INSTALLATION [cont'd]

Cable Terminations

Final connection from isolators, connection unit and


the like to equipment (measured elsewhere)
including cables, conduit and all fittings, accessories
etc. all as required and specified by the Engineer

A Fan coil units 8 No

B Exhaust fan 1 No

C Water heaters 5 No

D Main telephone connection box 1 No

E Annunciator panel 1 No

F Intruder alarm master panel 1 No

Carried to Collection
3 / 57 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

LIGHTING AND POWER INSTALLATION [cont'd]

Lighting

"Fix Only" lighting fixtures including all necessary,


fixing and fittings, accessories all as specified and
directed by the Engineer

A Type A 2 No

B Type B 13 No

C Type C 4 No

D Type D 7 No

E Type E 20 No

F Type F 78 No

G Type G 9 No

H Type H 4 No

J Type I 4 No

K Type J 2 No

L Type K 5 No

M Type L 15 No

N Type M 2 No

P Type 20EL418 4 No

Q Type 40RP418 10 No

Rev-1
31/3/01 Carried to Collection

3 / 58 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

LIGHTING AND POWER INSTALLATION [cont'd]

Installation and Accessories

Lighting switches including conduits, cables and


wires all as specified

A One way one gang switch 15 No

B One way two gang switch 4 No

C One way three gang switch 9 No

D Deleted

E Deleted

F Two way one gang switch 2 No

G Two way two gang switch 3 No

H Ditto, weatherproof 1 No

J One way one gang dimmer 4 No

K One way two gang dimmer 4 No

L Two way one gang dimmer 6 No

M Two way two gang dimmer 2 No

N 20A DP switch 7 No

P 45A DP switch 1 No

Rev-1
31/3/01 Carried to Collection

3 / 59 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

LIGHTING AND POWER INSTALLATION [cont'd]

Installation and Accessories[cont'd]

Socket outlets and other accessories complete


including conduits, cables all as specified

A 13A socket outlet, simplex 16 No

B 13A socket outlet, duplex 37 No

C Ditto, weather proof 1 No

D Switched fused connection 8 No

E Outlet box 8 No

F Flex outlet 8 No

G Deleted

H Deleted

J Outlet box for control equipment 8 No

Light point complete with conduits, cables and wires


all as specified

K Light points 179 No

Rev-1
31/3/01 Carried to Collection

3 / 60 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

LIGHTING AND POWER INSTALLATION [cont'd]

External Works

Cable duct

PVC pipes including all necessary fittings and


accessories, cleanouts etc. fixing in position all
complete as per drawings and specification

A 100mm dia 10 m

Manhole

B Manhole including all excavation, disposal and


surplus material, blinding, reinforced concrete base,
wall and medium duty cover complete as per the
drawing E001 1 No

Provisional Sum

C Allow provisional sum for supply of light fittings Sum 39,500.00

D Overhead and profit for ditto %

Carried to Collection

3 / 61 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

TELEPHONE AND CATV SYSTEM

Supply and install the complete telephone system as


specified including all necessary fittings and the like,
fixing in position complete

Accessories

A Main telephone connection box MTC-GFV 1 No

B Telephone connection box TC-FFV 1 No

C CATV-GFV 1 No

D Telephone socket outlet 17 No

Conduit and cables all as specified

E Main telephone connection box MTC-GFV 1 No

F Telephone connection box TC-FFV 1 No

G CATV-GFV 1 No

H Telephone socket outlet 17 No

EXTERNAL WORKS

Cable duct

PVC pipes including all necessary fittings, and


accessories, cleanouts etc. fixing in position all
complete as per drawings and specification.
J 50 mm dia 24 m

Manhole

K Manhole including all excavation, disposal and


surplus material, blinding, reinforced concrete base,
wall and medium duty cover complete as per the
drawing E001 1 No
Rev-1
31/3/01 Carried to Collection

3 / 62 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

TV SYSTEM

Supply and install the complete TV system as


specified including all necessary fittings and the like,
fixing in position complete

A Splitter 2 No

B Television socket outlet 10 No

Conduits and cables as specified

C Splitter 2 No

D Television socket outlet 10 No

EXTERNAL WORKS

Cable duct

PVC pipes including all necessary fittings and


accessories, cleanouts, etc. fixing in position all
complete as per drawings and specification

E 50mm dia 10 m

Manhole

F Manhole including all excavation, disposal and


surplus material, blinding, reinforced concrete base,
wall and medium duty cover complete as per the
drawing E001 1 No

Rev-1
31/3/01 Carried to Collection

3 / 63 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

BELL SYSTEM

Supply and install the complete bell system as


specified including all necessary fittings and the like,
fixing in position complete

A Annunciator panel 1 No

B Door Bell push button 2 No

C Indoor bell pushbutton 9 No

D Door bell chime 1 No

Conduits and cables as specified

E Annunciator panel 1 No

F Door Bell push button 2 No

G Indoor bell pushbutton 9 No

H Door bell chime 1 No

Carried to Collection

3 / 64 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

INTRUDER ALARM SYSTEM

Supply and install the complete intruder alarm


system as specified including all necessary fittings
and the like, fixing in position complete

A Intruder alarm central unit 1 No

B Door sensor 4 No

C Window sensor 7 No

D Intruder alarm bell 1 No

Conduits and cable as specified

E Intruder alarm central unit 1 No

F Door sensor 4 No

G Window sensor 7 No

H Intruder alarm bell 1 No

Rev-1
31/3/01 Carried to Collection

3 / 65 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

INTRUDER ALARM SYSTEM [cont'd]

EXTERNAL WORKS

Cable duct

PVC pipes including all necessary fittings and


accessories, cleanouts, etc. fixing in position all
complete as per drawings and specification

A 50mm dia 10 m

Manhole

B Manhole including all excavation, disposal and


surplus material, blinding, reinforced concrete base,
wall and medium duty cover complete as per the
drawing E001 1 No

Carried to Collection

3 / 66 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

EARTHING SYSTEM

A Supply, install, test and commission earthing system


comprising main earth electrode, pits, earth
continuity conductors, bonding and the like, as
specified and as shown on drawings complete 3 Item

Carried to Collection
3 / 67 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

ELECTRICAL INSTALLATION [cont'd]

SUNDRIES

A Laison coordination and attendance on DEWA work


to meet the requirement of the specification Item

B Ditto, but ETISALAT work Item

C Allow for providing holes, sleeves, mortises, chases,


supports, and the like and making good Item

D Allow for plates, labels, protective painting etc., and


for the identification of the installation as specified Item

E Allow for providing tools and spare parts as required


for the identification of the installation as specified Item

F Allow for providing operation and maintenance


manuals, shop drawings, `as built' drawings etc., as
specified Item

G Allow for testing and commissioning as specified Item

H Allow for incidental work Item

J Allow for protective painting Item

K Allow for decorative painting Item

L Allow for any additional item not included above but


necessary for the successful completion of the
Electrical Installation Item

Carried to Collection

3 / 68 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

COLLECTION

From page 3 / 56
From page 3 / 57
From page 3 / 58
From page 3 / 59
From page 3 / 60
From page 3 / 61
From page 3 / 62
From page 3 / 63
From page 3 / 64
From page 3 / 65
From page 3 / 66
From page 3 / 67
From page 3 / 68

TOTAL - ELECTRICAL INSTALLATION


Carried to Summary

3 / 69 19/03/2001
DUBAI INVESTMENTS PARK
THE GREEN COMMUNITY - PHASE 1
SHOW HOUSES

BILL No. 3 - FAMILY VILLA TYPE A

ITEM DESCRIPTION QTY UNIT RATE TOTAL (Dhs.)

SUMMARY

SUBSTRUCTURE 3/4

SUPERSTRUCTURE 3/7

BLOCKWORK 3/8

ROOFING AND WATERPROOFING 3 / 11

METAL WORK 3 / 12

DOORS AND WINDOWS 3 / 15

CARPENTRY AND JOINERY 3 / 16

FINISHES 3 / 23

PAINTING AND DECORATION 3 / 26

SANITARY FITTINGS AND FIXTURES 3 / 30

EXTERNAL WORKS 3 / 31

MECHANICAL INSTALLATION 3 / 55

ELECTRICAL INSTALLATION 3 / 69

TOTAL BILL No. 3 - FAMILY VILLA TYPE A


Carried to Main Summary

3 / 70 19/03/2001