Sunteți pe pagina 1din 2

Page 1

Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-4-10 / 9:50 ABM - WRS
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0692029 Rectangular Concrete 216 x 154.5
Site ID: Address: Site Quality: Basin:
9 2300 South 60th Street Poor

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? Yes Manhole Depth (ft): 20.25 Surcharge Evidence? No
Needed Traffic Attendants: 2 Manhole Dia. (in): 3 Depth of Surcharge (ft): 0
H2S: 0 O2: 20.8 MH Cover Size (in): 24 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: 1 Vent Pick Usable MH Steps? No
Describe potential hazards: Measured Flow Depth (in): 4 Meter: ADFM
Velocity (fps): 3.5 Cellular Signal Strength:
Normal High Traffic Hazards
Mounting Band Description: Antennae Install Considerations:

Half Band Mount Needs a vented cover

Other Comments: Permanent Power Available?

No
Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)


154.5 216
154.375 215.5625
216
154.0625 215.4375
216

SURFACE DOWN

INFLOW OUTFLOW