Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-5-10 DMH-ABM-LWW-WRS-JRW
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0118028 Circular RCP 48
Site ID: Address: Site Quality: Basin:
29 4740 Hamilton St. Poor

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? Yes Manhole Depth (ft): 12.24 Surcharge Evidence? No
Needed Traffic Attendants: Yes Manhole Dia. (in): 60 x 45 Depth of Surcharge (ft): 0
H2S: 0 O2: 20.8 MH Cover Size (in): 25.75 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: vented Usable MH Steps? No
Describe potential hazards: Measured Flow Depth (in): 4.5 Meter: 2150
Velocity (fps): 2 Cellular Signal Strength: Good
Mounting Band Description: Antennae Install Considerations:

Scissor, anchors, tapcons, drill, tape, Vented lid


ties

Other Comments: Permanent Power Available?

City requested a downstream set. Yes


Flow is turbulent in the MH and might
not give the best readings.
Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)

SURFACE DOWN

INFLOW OUTFLOW