Sunteți pe pagina 1din 2

Page 1

Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-5-10 / 9:15 ABM - WRS
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0644057 Circular Concrete 12
Site ID: Address: Site Quality: Basin:
52 4201 South 43rd St. Good

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? No Manhole Depth (ft): 12.14 Surcharge Evidence? Yes
Needed Traffic Attendants: 0 Manhole Dia. (in): 48 Depth of Surcharge (ft): 2
H2S: 0 O2: 20.8 MH Cover Size (in): 24 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: vented Usable MH Steps? Yes
Describe potential hazards: Measured Flow Depth (in): 2 Meter: 2150
Velocity (fps): 3 Cellular Signal Strength: Good
Normal Hazards
Mounting Band Description: Antennae Install Considerations:

Scissor Vented cover

Other Comments: Permanent Power Available?

Yes
Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)

SURFACE DOWN

INFLOW OUTFLOW

S-ar putea să vă placă și