MONITORING RELAYS

These relays are best suitable for monitoring


balanced or unbalanced supplies, either of single
phase, 3-phase 3-wire or 3-phase 4 wire loads
powered by generators, UPS, stabilizers, inverters,
or Mains (by Electricity Boards / Utilities); in AMF
panels, PCCs, distribution boards and for power
monitoring of individual loads / motors / pumps.
MODELS
D1 VCR1, S1 VMR2, S1 VMR4,
VCT D2, VCF D2, D2 VCT1, D1 VCT1,
S2 VMR 4, S2 VMR 5,
D2 EFR1, CCSD2, OCS D1,
S2 CMR2, S2 CMR3, S2 CMR4, S1 CMR1, S1 CMR2,
OFS D1, S2 FMR2, S1 FMR1,
RPT D2, RPF D2,
PMR D2 + PTS D1,
F3 VSR1, F3 VSR2

FEATURES PROTECTIONS / FUNCTIONS


• Fixed/adjustable under/Over trip • Under/over Voltage,
settings for parameters. • Under/Over Current
• Fixed/adjustable trip delays and Power • Under/Over Frequency
On delays • Under/Over Power
• Built-in or external power supply • Reverse Power
• Resetting – Auto or Manual • Earth Fault/Ground Fault
• Output contacts : 1 CO or 2 CO • Earth leakage
• Choice of enclosures (DIN-Rail, Flush)
• Models with Micro-Controller based
design
• 2 line alpha-numeric LCD display (for
F3 VSR1/2)
• Serial Communication (RS232) port Ordering Instructions
(for F3 VSR1/2 models)
• Use of SMD Technology Product Family Name
ü
• User-friendly LED indications Model Name
ü
System Supply Voltage
ü
& frequency
Aux. Supply/Control
ü
supply voltage
Current input (1A or 5A)
ü

15
VOLTAGE MONITORING RELAYS
S1 VMR2 D1 VCR 1 VCT D2 VCF D2
Voltage Monitoring Voltage Monitoring
1 Phase Voltage Monitoring Relay
Relay, 3Ø-3W Relay, 3Ø-4W

C US

Single Phase Under and Single Phase Under & 3-Phase 3-Wire Under 3-Phase 4-Wire Under
Over voltage, Over voltage, Auto Reset, & Over voltage & Over voltage
Auto Reset, Adjustable under / over Auto/Manual Reset, Auto/Manual Reset,
Adjustable UV/OV voltage settings, 2 CO Adjustable under/over Adjustable under/over
settings, output relay. voltage settings, voltage settings,
fixed trip delay, adjustable trip delay & adjustable trip delay &
1 CO output relay. ON delay, ON delay,
2 CO output relay 2 CO output relay

System Supply 100-120/220-240/380/440VAC±20% 220/230/240 V AC (+ 20% - 30%), 50/60 Hz ± 110/240/380/415/440 V AC +20%, – 25% 50/60Hz
Output Relay Contact 1 CO 2 CO 2 CO 2 CO
Trip Setting
Under Voltage 75 to 115 V AC±3% of set value 75 - 95% [Variable] of set value 75% - 95% (adjustable) 75% - 95% (adjustable)
160 to 230 V AC±3% of set value
285 to 425 V AC±2% of set value

Over Voltage 105 to 145 V AC±3% of set value 105 - 120% [Variable] of set value 105% -120% (adjustable) 105% -120% (adjustable)
230 to 300 V AC±3% of set value
400 to 520 V AC±2% of set value

Trip Time Delay 4±1 Sec (Fixed) (UV/OV) 2- 5 Sec (Fixed) (UV/OV) 1-10 secs. (adjustable) 1-10 secs. (adjustable)
Power on Delay — 1-10 secs. (adjustable) 1-10 secs. (adjustable)
Reset Auto Reset Auto Reset Auto / Manual Auto / Manual
Weight 90 gms. (Approx). 180 gms. 450 gms. 450 gms.
Dimensions (mm)
Overall (L x W x D) 89 x 17.5 x 59 (Approx). 76 x 30.5 x 117.5 76 x 56.5 x 117.5 76 x 56.5 x 117.5
Mounting 35 mm rail mounting 68 centre to centre / 35 mm rail 67 x 46 / 35 mm rail 67 x 46 / 35 mm rail
mounting mounting mounting

• Wherever not specified


Contact Rating :
OV SET
5A @ 230 V AC POWER OV RESET
(resistive) OV SET
3 Ph
OV OV RESET
1 Ph N
UV RESET
UV RESET
UV SET
UV UV SET
TD 2 to 5sec. TD
TD
1 to 10sec. TD
T2
T1 13 14 1 2
T on
4 5 13 14 16 17 1 to 10sec.
13 15 1 3

4 6
13 15 16 18

L L
O
A
L R
L
N D R
R O Y O
OFF ON Y A B A
Y
D1 VCR1 B
D D
N
B 1 2 3
N/V
OFF OFF
N
ON
ON N/V
OFF D1 VCR1
N/V 1 2 3 4 5 6
N/V ON 1 2 3 4 5 6
VCF D2
VCT D2 A/M
7 8 9
LINK
A/M
LINK
S1 VMR2
13 14 15
7 8 9 10 11 12
7 8 9 10 11 12

13 14 151617 18
4 5 6 13 14 151617 18

Relay position shown in Relay contact position shown in 'Power on' (Healthy) condition
‘Power off’ condition
16
VOLTAGE MONITORING RELAYS
D1 VCT1 S1 VMR4 D2 VCT1 S2 VMR4 S2 VMR5
Voltage Monitoring Voltage Monitoring Voltage Monitoring Voltage Monitoring Voltage Monitoring
Relay, 3Ø-3W Relay 3Ø-3W Relay Relay, 3Ø-3W Relay, 3Ø-4W

R R R

C US C US C US

3-Phase 3-Wire Under 3-Phase 3-Wire Under & 3-Phase 3-Wire and 3-Phase 3-Phase 3-Wire Under & Over 3-Phase 4-Wire Under & Over
& Over Voltage, Over voltage, 4-Wire (selectable) Under & Over voltage, Microcontroller based voltage, Microcontroller based
Auto reset, Auto Reset, Adjustable voltage, Microcontroller based design, SMD Technology design, SMD Technology, Auto /
design, Auto/Manual Reset, Auto/Manual Reset, , Adjustable Manual Reset, Adjustable
Adjustable UV/OV UV/OV voltage settings, Adjustable under/over voltage under/over voltage settings, under/over voltage settings,
settings, Fixed trip delay, settings, Absolute values for Absolute values for UV/OV, Absolute values for UV/OV,
fixed trip delay, 1 CO output relay UV/OV, adjustable trip delay & adjustable trip delay & ON delay, adjustable trip delay & ON delay,
2 CO output relay. ON delay, 2 CO output relay (or 2 CO output relay (or selectable 2 CO output relay (or selectable
selectable 1CO for UV, 1CO for OV) 1CO for UV, 1CO for OV) 1CO for UV, 1CO for OV)
Failsafe-non-failsafe selectable Failsafe-non-failsafe selectable Failsafe-non-failsafe selectable

100-120/220-240/380-440 V AC 110/230/415 V AC ± 20% 100-120 / 220-240 / 380-440V AC ± 20%, 50/60 Hz 100-120 / 220-240 / 380-440V AC ± 20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC ± 20%, 48-63 Hz
2 CO 1 CO 1 CO + 1 CO / 2 CO 1 CO + 1 CO / 2 CO 1 CO + 1 CO / 2 CO
Ph Ph Setting:
For 380-440V AC 285-425V AC (Variable) 285 - 425V AC (Variable)
75-115 Unit of 100-120 V AC 75% - 95% (adjustable)
For 220-240V AC 165-225V AC (Variable) 165-225V AC (Variable)
165-225 Unit of 220-240 V AC For 100-120V AC 75-115V AC (Variable) 75-115V AC (Variable)
285-425 Unit of 380-440 V AC Ph N Sensing:
For 380-440V AC 165-245V AC (Variable) 165-245V AC (Variable)
For 220-240V AC 95-135V AC (Variable) 95-135V AC (Variable)
For 100-120V AC 45-65V AC (Variable) 45-65V AC (Variable)
Ph Ph Sensing:
105-145 Unit of 100-120 V AC 105% - 125% (adjustable) For 380-440V AC 400-520V AC (Variable) 400-520V AC (Variable)
230-290 Unit of 220-240 V AC For 220-240V AC 230-290V AC (Variable) 230-290V AC (Variable)
400-520 Unit of 380-440 V AC For 100-120V AC 105-145V AC (Variable) 105-145V AC (Variable)
Ph N Sensing:
For 380-440V AC 230-310V AC (Variable) 230-310V AC (Variable)
For 220-240V AC 130-170V AC (Variable) 130-170V AC (Variable)
For 100-120V AC 60-80V AC (Variable) 60-80V AC (Variable)

3.5±1.5 Sec (UV/OV) 4 Sec ± 1 Sec (Fixed) 1-10 Sec (Variable) SP/UV/OV 1-10 Sec. (Variable) 1-10 Sec. (Variable)
4 Sec ± 1 Sec (Fixed) 1-10 Sec (Variable) 1 10 Sec (Variable) 1 10 Sec (Variable)
Auto Reset Auto Reset Auto/ Manual Reset Auto / Manual Reset Auto / Manual Reset
200 gms. (Approx). 100 gms. 300 gms (Approx.) 110 gms (Approx.) 110 gms (Approx.)

76 x 30.5 x 117.5 89 X 17.5 X 59 76 X 56.5 X 117.5 90 X 35 X 60 90 X 35 X 60


68 centre to centre / 35 mm rail 35 mm rail mounting 67 x 46 / 35 mm rail mounting 35 mm Rail Mounting 35 mm Rail Mounting
mounting

POWER
OV SET
OV SET
3 Ph
OV RESET

UV RESET
OV OV SET
OV RESET
OV SET
OV RESET
OV RESET
UV SET 3 Ph N
3 Ph ~ 3 Ph N 3 Ph

TD TD UV RESET
3.5 sec.
UV UV SET
UV RESET
UV SET
UV RESET UV SET
TD
13 14 1 2 T2 TD
1 to 10sec. TD
TD
1 to 10sec. TD
1 to 10sec. TD

T1 T on T on
7 8 10 11
T on
1 to 10sec.

13 15 1 3
4 5 13 14 16 17 1 to 10sec. 7 8 10 11 1 to 10sec.

4 6 13 15 16 18 7 9 10 12 7 9 10 12

R
L
O Y
R R
A
D
B L Y Y
O
A B B
D
N/V
OFF N N
ON
A/M
DOL STARTER LINK
OFF
S1 VMR4

D2 VCT1
4 5 6

Relay position shown in ‘Power off’ condition Relay position shown in 'Power off' condition
17
CURRENT MONITORING RELAYS
OCS D1 S2 CMR2 S1 CMR1 S1 CMR2
1 Phase Over 1 Phase Current 1 Phase Under 1 Phase Over
Current Relay Monitoring Relay Current Relay Current Relay

R R R

C US C US C US

Single phase over Single phase under & over Single Phase Over Single Phase Under
current Microcontroller based
current Auto reset, Current, Auto Reset, Current, Auto Reset,
design, SMD technology,
Input 1A or 5 A through Auto/Manual reset, Input 1A or fixed power on delay and fixed power on delay and
CT, Adjustable over 5 A through CT, Adjustable trip delay, Adjustable trip delay, Adjustable
current trip settings, under / over current trip over current trip under current trip
Adjustable trip delay, settings, adjustable trip delay settings, Input from settings, Input from
& ON delay, 2 CO output relay
1 CO output relay (or selectable 1CO for UC, 1CO
5A(or 1A) secondary CT, 5A(or 1A) secondary CT,
for OC) Failsafe-non-failsafe 1 CO output relay. 1 CO output relay.
mode selectable

Supply Voltage
System 110-120/220-240/380-440 V Ac±20%, 100-120 / 220-240 V AC ±20%, 100-120 / 220-240 V AC ±20%, 100-120 / 220-240 V AC ±20%,
Auxiliary 12 V DC/24/30 V Dc±10% 24 V DC ±10% 24 V DC ± 10% - 15% 24 V DC ± 10% - 15%
Ext. Input 1 Amp or 5 Amp (Secondary) CT 1 Amp or 5 Amp (Secondary) CT 5 Amp / 1 Amp Optional 5 Amp / 1 Amp Optional
Output contact 1 CO 1 CO + 1 CO 1 CO 1 CO

Trip setting
EF Trip Setting — — — —

Under Current N.A. 10% - 100% (Variable) 10% - 100% (Variable) N.A.

Over Current 50% -140% (adjustable) of CT sec 50% - 140% (Variable) N.A. 50% - 140% (Variable)
Power On Delay 3.5 secs ± 1.5 sec (fixed) 1-10 Sec. (Adjustable) ± 1 Sec. 10 ± 1 Sec. (Fixed) 10 ± 1 Sec. (Fixed)
Trip Time Delay 1 - 10 secs (adjustable) 1-10 Sec. (Adjustable) ± 1 Sec. 4 ± 1 Sec. (Fixed) 4 ± 1 Sec. (Fixed)
Resetting Auto Auto / Manual Auto Reset Auto Reset
Weight 250 gms. 140 gms 100 gms 100 gms
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 90 X 35 X 60 89 x 17.5 x 59 (Approx). 89 x 17.5 x 59 (Approx).
Mounting (L x W) 68 centre to centre / 35mm rail 35 mm Rail Mounting 35 mm Rail Mounting 35 mm Rail Mounting
Mounting

• Wherever not specified


Contact Rating :
5A @ 230 V AC Aux. Supply

(resistive) Aux. Supply


POWER POWER
OC SetPoint
OC Reset
OC SetPoint
OC Reset

UC SetPoint
UC Reset UC OC
Current Input
Current Input
Current AUTO Current AUTO
T ON
AUTO Input RESET Input RESET
2 to 5 sec. Td - T ON
RESET T1 T2 T1 T2
1 to 10 sec. 1 to 10 sec. Td -
13 14 7 8 10 11
1 to 10 sec. 4 5 4 5
13 15 7 9 10 12 4 6 4 6

L L
O Aux.
A
N
D Supply

N/V
1 2 3 DOL STARTER
OCS D1 OFF
ON OFF
N/V ON
AUX.
SUPPLY
7 8 9 1 2 3

13 14 15

S1 CMR1
S1 CMR2

4 5 6

Relay contact position shown in Relay position in ‘Power off' condition


‘Power on' (Healthy) condition

18
GROUND FAULT MONITORING RELAYS
D2 EFR1 S2 CMR3 S2 CMR4
Earth Fault Relay Ground Fault Relay Earth Leakage Relay

R R

C US C US

Earth fault/Ground fault monitoring of Earth fault/Ground fault monitoring of Earth leakage monitoring of 3 phase
3 phase systems 3 phase systems, Microcontroller based systems, Microcontroller based design,
Manual Reset, design, SMD technology, Manual Reset, SMD technology, Manual Reset,
Input 1A or 5A through CBCT, Input 1A or 5A through CBCT, Input through CBCT,
Adjustable earth fault trip setting, Adjustable earth fault trip setting, Adjustable trip setting,
adjustable trip delay, Adjustable trip delay & ON delay, Adjustable trip delay & ON delay,
2 CO relay output 2 CO relay output 2 CO relay output
Failsafe-non-failsafe seletable Failsafe-non-failsafe seletable

24-30 VDC / 100-120 / 220-240 / 380-440 V AC ±20% 100-120/220-240/380-440 V AC ± 20%, 48-63 Hz 100-120/220-240/380-440 V AC ± 20%, 48-63 Hz
100-120/220 -240 V AC / 24V DC ± 20% 100-110/240V AC / 24V DC ± 20%
1A or 5A (Selectable) CBCT
1 CO (2 CO) (Pick up on Fault) 2 CO 2 CO

10% -100% (adjustable) of CT sec 10% - 100% of Rated Current Input (Variable) 10% - 100% of Rated Current Input (Variable)
(Input through CT of 1AMP or 5AMP Secondary) (Input through CBCT of 300m A Secondary)

N.A. N.A. N.A.

N.A. N.A. N.A.


N.A. 1 -10 Sec.(Adjustable) 1 -10 Sec.(Adjustable)
0.1-1.0 / 1-10 Sec. (Adjustable) 0.1 - 1 Sec.(Adjustable) 0.1 Sec to 1 Sec.(Adjustable)
Manual / Remote (Selectable) Manual Manual
550gms. 140 gms 140 gms

76 x 56.5 x 117.5 90 X 35 X 60 90 X 35 X 60
67 x 46 / 35 mm rail Mounting 35 mm Rail Mounting 35 mm Rail Mounting

Td Td

13 14 16 17

13 15 16 18

EXTERNAL CBCT(ZCT)
5 Amp. CT. CBCT ( ZCT)

R Ø R
Y Ø M
MOTOR
Y M
B
B Ø

OFF ON
OFF ON
N/V N/V

1 2 3 4 5 6
AUX.
SUPPLY
D2 EFR1 *Use either S2 CMR 4
Ø
Ø 3 x 5A Ext. CTs
or 3 x 1A Ext. CTs 7 8 9 10 11 12

13 14 15 16 17 18
or 1 x 5A (or 1A) CBCT

Relay position in Relay position shown in 'Power off' condition


'Power on' (Healthy) condition

19
FREQUENCY MONITORING RELAYS
S1 FMR1 OFS D1 S2 FMR1
Over Frequency Relay Over Frequency Relay Frequency Monitoring Relay

R R

C US C US

Single Phase over frequency, Single phase over frequency Single phase under & over
Auto reset, Auto reset, frequency, Microcontroller based
Adjustable over frequency trip Adjustable over frequency trip design, SMD technology, Auto
setting, settings,' reset, Adjustable under/over
Fixed power ON delay and trip delay, Adjustable trip delay, frequency trip settings,
1 CO output relay. 1 CO output relay Adjustable trip delay & ON delay,
2 CO output relay Failsafe-non-
failsafe mode selectable

Supply Voltage
System 100-120 / 220-240 V AC ± 20% 100-120 / 220-240 / 380-440 V AC ±20% 100-120 / 220-240 V AC ± 20%, 38-72 Hz
Auxiliary — 12 / 24 V DC or Built in In Built or 24V DC ± 20%
Ext. Input — —
Output contact 1 CO 1 CO 1 CO + 1 CO
Trip setting
Under Frequency N.A. 40 Hz - 60 Hz (Variable)
Over Frequency 50 Hz to 70 Hz (Variable) ± 1 Hz of set Frequency 50 Hz - 70 Hz 50 Hz - 70 Hz (Variable)
Under Power — — —
Over Power — — —
Reverse Power — — —
Power On Delay 10 ± 1 Sec. (fixed) 3.5 secs. ± 1.5 sec (fixed) 1 - 10 Sec.(Adjustable) ± 1 Sec.
Trip Time Delay 4 ± 1 Sec. (fixed) 1 - 10 secs. (adjustable) 1 - 10 Sec.(Adjustable) ± 1 Sec.
Resetting Auto Auto Auto / Manual
Weight 90 gms. (Approx). 450 gms. 130 gms
Dimensions (mm)
Overall (L x W x D) 89 x 17.5 x 59 (Approx). 76 x 30.5 x 117.5 90 X 35 X 60
Mounting (L x W) 35 mm Rail Mounting 68 centre to centre / 35 mm Rail Mounting 35 mm Rail Mounting

• Wherever not specified POWER Aux. Supply


Contact Rating :
5A @ 230 V AC OF SetPoint
(resistive)
Aux. Supply
OF OF Reset

OF SetPoint
OF Reset
UF Reset
Freq. Input UF SetPoint

T1 T2 Freq. Input
AUTO
T ON RESET
4 5 2 to 5 sec. Td - T ON
1 to 10 sec.
1 to 10 sec. Td
13 14 1 to 10 sec.
7 8 10 11

4 6 13 15 7 9 10 12

L L
O
Aux. N
A
D
L
O
Supply A
D
OFF ON

OFF ON

N/V
OFF DOL STARTER
N/V ON N/V
DOL STARTER

1 2 3

OFS D1

S1 FMR1 7 8 9

13 14 15

4 5 6

Relay position in 'Power off' condition Relay contact position shown in Relay position in 'Power off' condition
20 ‘Power on' (Healthy) condition
POWER MONITORING RELAYS
RPT D2 RPF D2 PMR D2 + PTS D1
Reverse Power Relay,(3Ø-3W) Reverse Power Relay,(3Ø-4W) Motor Power Monitoring Relay

3-phase 3-wire generators reverse Single phase or 3-phase 4-wire Under Power & Over Power Monitoring
power monitoring generators reverse power monitoring Auto/Manual Reset,
Auto/Manual reset, Auto/Manual reset, Adjustable UP/OP settings,
Reverse power (current) trip settings Reverse power (current) trip settings Adjustable On delay and trip delay,
adjustable, adjustable, 2 CO output relays
ON delay and trip delay adjustable, ON delay and trip delay adjustable,
2 CO output relay 2 CO output relay

100-120 / 280-240 / 380-440 V AC ±20% 100-120 / 280-240 / 380-440 V AC ±20% 110/240/380/415 V AC ±20%
Built-in Built-in Built-in
5A, CT & R,Y, B 5A, CT & R,Y, B PTS D1 (1A/5A CT & 3Ph)
2 CO 2 CO 1 CO + 1 CO

— — —
— — —
— — 10% - 100% (adjustable)
— — 10% - 100% (adjustable)
2% - 20% (adjustable) 2% - 20% (adjustable) —
1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable.) 1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable)
Auto / Manual Auto / Manual Auto / Manual
460 gms. 460 gms. 400 gms. (For PMR D2), 325 gms. (For PTS D1)

76 x 56.5 x 117.5 76 x 56.5 x 117.5 76 x 56.5 x 117.5 (For PMR D2), 76 x 30.5 x 117.5 (For PTS D1)
67 x 46 / 35 mm Rail Mounting 67 x 46 / 35 mm Rail Mounting 67 x 46 / 35 mm Rail Mounting

POWER POWER On
Supply
Off
SOURCE SOURCE
Td
1
ASYN.
MOTOR
2
ASYN.
MOTOR

% over
RPT D2 / RPF D2 RPT D2 / RPF D2 Power Setting
3 Ph
Supply % under
Power Setting
Forward Power Increasing Foward Current Start Start
Reverse Power Increasing Reverse Current Up Delay Up Delay
Td
Recovery
Level
Zero Power
Current Tripping during power on
Level
Under On
Power Relay 13 14 Off
On
13 14 16 17 Off
ASYN.
Over
LOADMOTOR
T ON
Td 1 to 10 sec.
Power Relay
16 17
13 15 16 18 1 to 10 sec. Current Zero

R
L
O
Y A
P1 P2
D
B L
S1 S2
External
5 Amp Secondary CT
G O
A
R
Y MOTOR
D B
P1 P2
S1 S2

1 2 3 4 5 6 OFF ON
NV
1 2 3 1 2 3 4 5 6 DOL STARTER
RPT D2
PTS D1 PMR D2
7 8 9 10 11 12
7 8 9 7 8 9 10 11 12
RPF D2
A/M R1 R2
LINK

13 14 15 13 14 15 16 17 18
13 14 15 16 17 18

Connection Cable

Relay contact position shown in 'Power on' (Healthy) condition 21


VOLTAGE SCANNERS & CONTROLLERS
F3 VSR1 F3 VSR2 F3 VSR3
Voltage Scanner 3Ø-3W Voltage Scanner 3Ø-4W Voltage Scanner & Phase Selector

DISCONTINUED

3-Phase 3-Wire voltage monitoring & 3-Phase 4-Wire voltage monitoring & 3-phase 4-wire system voltage
display, Phase Failure, Unbalance, Phase display, Phase Failure, Unbalance, monitor with phase selector
Sequence, under voltage, Over Voltage, Phase Sequence, under voltage, Over Under voltage and over voltage
Auto / Manual Reset, Voltage, Auto / Manual Reset, monitoring Auto reset,
Adjustable unbalance trip setting, Adjustable unbalance trip setting, Adjustable UV/OV trip settings,
Adjustable under/over voltage settings, Adjustable under/over voltage settings, Adjustable trip delay,
adjustable trip delay, Adjustable trip delay, 5x1No output relays.
RS232 communication port, RS232 communication port,
2 CO output relay 2 CO output relay

Supply voltage
System 380 / 415 V AC (3 Ph - 3 W) 380 / 415 V AC (3 Ph - 4 W) 415 VAC,+ 20 % -30 %, 50 Hz / (60Hz) ± 3 %
Auxiliary 90-270 V AC/DC Self Powered (Neutral & any Phase) 48 VDC ± 10 %
Output relay contacts 2 CO & RS 232 (optional) 2 CO & RS 232 (optional) 5 Nos. x 1NO.
Trip setting
Phase Sequence Yes Yes No
Phase Unbalance 1 - 10 % (Adj.) 1 - 10 % (Adj.)
Under Voltage 1 - 80V below nominal voltage 1 - 50V below nominal voltage 75 % TO 95 % [VARIABLE BY POT]
Over Voltage 1 - 60V above nominal voltage 1 - 25V above nominal voltage 105 % TO 120 % [VARIABLE BY POT]
Trip Time delay 1 - 60 secs. or 1-5 mins select. 1 - 60 secs. or 1-5 mins select. 1-10 SEC. [VARIABLE BY POT]
Reset Manual / Auto Manual / Auto Auto
Display Backlit LCD (16 x 2 character) Backlit LCD (16 x 2 character) —
Monitoring Phase to Phase Phase to neutral Phase to neutral
Weight 800 gms. 800 gms. 900 gms.
Dimensions (mm)
Overall (L x W x D) 96 x 96 x 130 96 x 96 x 130 96 x 96 x 130
Mounting (L x W) 92 x 92 92 x 92 92 x 92

RP, UV / OV and UB Protection override facility provided RP, UV / OV and UB Protection override facility provided On Delay - 3mins ± 10%

• Wherever not specified RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET
AUX.
Contact Rating : SP UB>SET RP SP UB>SET RP SUPPLY

5A @ 230 V AC OV SET OV SET


RO

(resistive) RYB RYB YO


LINE LINE
BO
UV SET UV SET T2 T2 T2
RO YO RO RO
SP SP HVAC
T1 T1 T1 T1
UV UV
t OV t UV t UB/SP t UB/SP UB/SP t OV t UV t UB/SP t UB/SP UB/SP SMPS BO
T1
YO
T1
BO

LED LED ALARM

RELAY RELAY T 1 - ON DELAY FOR HVAC AND SMPS.


C-NO C-NO T2 - TRIP DELAY.

AUX.
SUPPLY
N
B
Y
R
C2 NO2 NC2 C2 NO2 NC2

RS232 RS232 R Y B N D C1 NO1 C2 NO2

+ - D C3 NO3 C4 NO4 C5 NO5


R Y B C1 NO1 NC1 R Y B N C1 NO1 NC1

AUX.
SUPPLY
48V DC

R R
Y Y
B B
N

22 Relay contact position shown in 'Power on' (Healthy) condition

S-ar putea să vă placă și