Sunteți pe pagina 1din 236

SYMBOL DICTIONARY

DICTIONARY

3BW 45305 AAAA RKAHA Ed. 07


Status RELEASED 29/05/2002
Short title MNE283
All rights reserved. Passing on and copying of this document, use
and communication of its contents not permitted without written
authorization from Alcatel.

2 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

1 ORDERED LIST
A POSSIBLE STATUS ON RECEPTION ON A BUS
- Value of parameter
A OPERATING MODE VN5 (OLD )
- Value of MOD parameter
A AUXILIARIES
- Value of parameter
A SWITCH TO CALL PHASE
- Value of parameter
- Switching to call phase enables operator to call the subscriber by dialling the call
number indicated as a result.
- It is compulsory to switch to call phase before testing the subscriber set.
A I/C TRAFIC
- Value of parameter
A SIGNALLING LINK TRANSMISSION RATE = 4.8kbits/s
- Value of parameter D
A ATM NETWORK CHARACTERISTICS
- Parameter value
A ADDITION OF A 1-DIGIT OR 2-DIGIT ZONE CODE
- Value of DIS parameter
A BRANCH A OF THE SWITCHING MATRIX SYSTEM
- Possible value for the BRCX parameter
AAi TYPE A
- Value of GABC parameter
- Possible value : 1 ≤ i ≤ 15
AA ASCII
- Parameter value.
AAB ENTITLED TO ABSENT SUBSCRIBERS FACILITY
- Value of CAT parameter
AAMT ACTION ON THE TEMPORARY MODE ALLOWED
- Value of the CAT parameter
AB ADDITION OF DIGITS TO THE ROUTING CODE
- Value of parameter DIS
ABA ISDN EQUIPMENT WITH 2-WIRE ALTERNATION BASIC ACCESS
- Output symbolic name
ABA04 UT HAVING 16 ISDN EQUIPMENTS WITH 2-WIRE ALTERNATION BASIC ACC

3BW 45305 AAAA RKAHA Ed. 07 3 / 236


SYMBOL DICTIONARY

- Value of parameter
ABE EQUIPMENT WITH 2-WIRE ECHO-CANCELLING BASIC ACCESS
- Output symbolic name
ABE08 UT HAVING 8 EQUIPMENT UNITS W/2-WIRES AND ECHO-CANCELLATION
- Value of parameter
ABN SUBSCRIBERS ASSEMBLY
- Value of parameter
ABO OBSERVATION SUBSCRIBER RECORD
- Value of parameter TYP
ABQ ISDN EQUIPMENT WITH 4-WIRE BASIC ACCESS
- Output symbolic name
ABQ04 UT HAVING 4 ISDN EQUIPMENTS WITH 4-WIRE BASIC ACCESS
- Value of parameter
ABS ABSENT SUBSCRIBER
- Value of parameter MAR
ABSO ABSENT SUBSCRIBER (CALL FORWARDING ON OPERATOR)
- Value of parameter MAR
AC ACCESS CODE TO BE SENT
- Value of parameter
- From 1 to 15
- AC=10 for access code A0 in signalization MF
AC SELECTION OF SIGNALS INTERCHANGED DURING COMPLETE CALL
- Value of parameter MOD
ACC ACCEPTANCE OF PARAMETERS LINE
- Symbolic name printed out
ACCE SIGNALING POINT GLOBAL ACCESSIBILITY
- Symbolic name of parameter
- Possible values : INA, ACP, ACT, RES, NCR
ACD OVERFLOW ROUTING NUMBER
- Parameter value
- From 1 to 4095
ACE ACCESS MODE FOR A TEST CALL
- Value of parameter
- Possible values : 1 ≤ i ≤ 15
ACFi SIGNALLING ACCESSIBILITY FOR RANS SIGNALLING LINK SET (0<=i<=3)
- Symbolic output name (1 character)

4 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values :
- I : SP not accessible by this signalling link set
- A : SP accessible by this signalling link set
- X : link set inexistent in the combined link set
- R : request for restricted transfer by this SP via the link set
- H : unavailable signalling link set
ACH ROUTING
- Symbolic name of parameter
- From 1 to 4095
ACHA ROUTING FOR CALLING PARTY DIVERSION
- Parameter symbolic name
- Value : 0 to 4095
ACHAU ROUT. ENTRY POINT FOR ACCESS TO AUX. CIRC. GROUPS.
- Symbolic parameter name
- Possible value: from 1 to 4095
ACHB ROUTING FOR CALLED PARTY DIVERSION
- Parameter symbolic name
- Value : 0 to 4095
ACHN ROUTING INDEXED LIST ACHN = ACH-i
- Parameter value with :
• ACH : routing number, from 1 to 1023
• i : routing category, from 1 to 64
ACHVM ROUTING NUMBER OF VOCAL BOX
- Symbolic name of parameter
- Possible values : 1 to 1023
ACL NUMBER OF LLP ACTIVATION REQUESTS
- Symbolic name in output lists
ACM INDEXED LIST OF ROUTINGS ACM = ACH - i
- Value of parameter
- Possible value from 1 to 64 if i is a zone number
- from 1 to 100 if i is a percentage
ACM SECOND LEVEL - ROUTING NUMBER
- Parameter of ACHIL command
- Possible value from 1 to 4095
ACP SIGNALLING POINT PARTIALLY ACCESSIBLE
- Value of parameter ACCE

3BW 45305 AAAA RKAHA Ed. 07 5 / 236


SYMBOL DICTIONARY

ACPS FIRST LEVEL PERMANENT ACCESS ACTIVATION "S" INTERFACE


- Valeur du paramètre TY
ACPU FIRST LEVEL PERMANENT ACCESS ACTIVATION "U" INTERFACE
- Valeur du paramètre TY
ACP01 UT HAVING 1 ISDN EQUIPMENT WITH PRIMARY RATE ACCESS CAPABILITY CRC4
- Value of parameter
ACP2 SECOND LEVEL PERMANENT ACCESS ACTIVATION "T" INTERFACE
- Valeur du paramètre TY
ACRDA NUMBER OF SERVER ROUTING FOR RDA/CALL-RETURN
- Symbolic name of parameter
- Possible values : 1 to 1023
ACRJ__ Anonymous Call Rejection
-
ACS ROUTING REQUIRING ECHO SUPPRESSOR
- DIS parameter value
ACSS Acces code of the called party’s SCCP number
- Symbolic name of parameter
ACT ACTION
- Symbolic name of parameter
- Possible values :
• CCX
• LCT
ACT SIGNALLING POINT TOTALLY ACCESSIBLE
- Value of parameter ACCE
ACT CRC4 ACTIVE ON THE PCM LINK
- Value of CRC parameter
ACT ACTIVATION OF THE CRC4 OF A PRIMARY RATE ACCESS
- Value of the TY parameter
ACT ACTIVATION TYPE
- Symbolic name of parameter
ACT BIT LIST FOR CALL ROUTING IMPOSED BY CALL FORWARDING
- Symbolic name of parameter
- The value is assigned in the form <INDEX>-<BIT>,
- INDEX : range of values 0 to 15
- BIT : range of values 0 and 1
ACT TYPE OF COMMUNICATION CHANNEL (ACTIVE OR BACKUP)
- Symbolic name of parameter

6 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible value : NO or YES (implicit value)


- Parameter present and "NO " value : BACKUP
- Parameter absent or "YES" value : ACTIVE
ACT CHARGING MODE IN USE
- Output symbolic name
ACTI ACTIVATION OF THE PRESET CALL FORWARDING
- Symbolic name of parameter
- Possible value : YES or NO (implicit value)
- Parameter present and "YES" value : Activate preset call forwarding service.
- Parameter absent or "NO" value : No service activation.
ACTI ACTIVE SIGNALLING LINK
- Value of parameter ETCS
ACTIF FILTER STATUS
- Symbolic output name
ACTU FIRST LEVEL TEMPORARY ACCESS ACTIVATION ON "U" INTERFACE
- Valeur du paramètre TY
ACTV CHECK FOR THRESHOLD OVERRUN ON PROCES DATA COUNTER
- Symbolic name of parameter
- Possible values : Yes or No
ACT2 SECOND LEVEL TEMPORARY ACCESS ACTIVATION ON "T" INTERFACE
- Valeur du paramètre TY
AC1 ACCESSIBILITY OF THE PS/PSE USED IN NORMAL MODE OR STATE OF THE SUBSYS-
TEM FOR THIS PS/PSE
- Symbolic output name
- Possible values :
H : inaccessible PS or inaccessible PSE
- A : accessible PS or PSE and authorized NSS
- I : unauthorized NSS
- PS : Signalling point
- PSE: Extended signalling point
AC1 ROUTE 1 OF TIME-RELATED ROUTING
- Value of parameter
AC2 ROUTING 2 OF TIME-DEPENDENT ROUTING
- Parameter value
AC2$$2 ACCESSIBILITY OF THE PS/PSE USED IN BACK-UP MODE OR STATE OF THE SUBSYS-
TEM FOR THIS PS/PSE
- Symbolic output name

3BW 45305 AAAA RKAHA Ed. 07 7 / 236


SYMBOL DICTIONARY

- Possible values :
H : inaccessible PS or inaccessible PSE
- A : accessible PS or PSE and authorized NSS
- I : unauthorized NSS
- PS : Signalling point
- PSE: Extended signalling point
AC3 ROUTING 3 OF TIME-DEPENDENT ROUTING
- Parameter value
ADn ADDRESS
- Symbolic name printed out
- Possible values : AD1, AD2, AD3
AD NUMBER OF OUTGOING CALLS
- Symbolic name printed out
ADAPT ADAPTOR NUMBER
- Symbolic name printed out
ADL EQUIPMENT FOR A DEDICATED 64K-BIT LINK
- Output symbolic name
ADL04 4-EQUIPMENTS TU USED AS A LINE ADAPTOR
- Value of parameter
ADM ACTIVE STATUS OF THE DELAYED NOTIFICATION SERVICE
- Value of the MAR parameter
ADMS Administrative state
- Symbolic name of parameter
- It can take following values :
• ES
• BLOM
ADN DO NOT DISTURB ACTIVE
- MAR parameter value
ADP ISDN EQUIPMENT WITH PRIMARY RATE ACCESS
- Output symbolic name
ADPO ROUTING RESERVED FOR OP CALLS
- Value of DIS parameter
ADP01 UT HAVING 1 ISDN EQUIPMENT WITH PRIMARY RATE ACCESS
- Value of parameter
ADR MEMORY ADDRESS
- Symbolic parameter name

8 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Hexadecimal value in the form H’xxxxxxxx’.


ADR NETWORK LINE ADDRESS
- Symbolic name printed out
- On the form <UR>-<LR>-<IT>
ADRS BYTE ADDRESS IN A PROGRAM
- Symbolic name of parameter
- In the form : H’----’
AEAC AUTOMATIC TEST ENABLED
- Symbolic name of parameter
- Possible values : Yes (by default) No
AECH EXISTENCE OF ECHO CANCELLER
- Value of parameter CTA
AECHO CHARACTERISTICS OF THE ECHO CANCELLERS
- Parameter symbolic name
- The possible values are as follows:
- ECHOLi Duration of the temporary echo processing window
- (i from 1 to 4)
- ERLi Natural attenuation threshold of the echo route
- to be taken into account by the AE (echo canceller)
- (i from 1 to 3)
- DIRi Orientation of the AE
- (i from 1 to 2)
- BITCi Status of bit C to transmit in TS 16 of the outgoing PCM
- (i from 1 to 2)
- HLCi Voice signal attenuation in the Rx direction
- (i from 1 to 4)
- MTDi Inhibition mode of AEs with regard to modems
- (i from 1 to 3)
- RDAEi Delay in beginning the temporary echo processing window
- (i from 1 to 625)
AEGR AUTHORIZATION FOR SENDING A GROUP MESSAGE
- Value of parameter CTA
AEMn SEND ATTENUATION
- Parameter TY value
- Possible values : 1 < n < 3
AEN ENTITLED TO RECORDED CALLS

3BW 45305 AAAA RKAHA Ed. 07 9 / 236


SYMBOL DICTIONARY

- Value of parameter CAT


AEPn ECHO CANCELLER CATEGORY IN MOBILE POOL
- Parameter value
- Possible value : 1 ≤ n ≤ 8
AE155 ATM-SDH-STM1-IWU electric applique
- PRF parameter value
AF FUNCTIONAL ADDRESS OF SOFTWARE MACHINE
- Symbolic parameter name
- Possible values, according to the command:
• ARCIN :
• COMAi, COMBi, ETAi, GXi, MQi, MRi, OCA, OCB, PCA, PCB, PUPEi
• SABAi, TRi, TXi, URMAi, URMBi
• CCi, GSi
• ARCMO :
• COMAi, COMBi, ETAi, GXi, MQi, MRi, OCA, OCB, PCA, PCB, PUPEi
• SABAi, TRi, TXi, URMAi, URMBi, ALL
• CCi, GSi
• ALL means all software machines (MLs) carrying the archive and the OM disk
archive.
• ESMIN :
• COMi, COMAi, COMBi, ETA, ETAi, GX, GXi, MQ, MQi, MR, MRi
• OC, OCA, OCB, PC, PCA, PCB, PUPE, PUPEi, SABAi, SEC,
• TR, TRi, TX, TXi, URMi, URMAi, URMBi
• CC, CCi, GS, GSi, ANi, ANAi, ANBi
• FEMAR, FEMIL, FEMLA, FFIMO :
• COMi, COMAi, COMBi, ETA, ETAi, GX, GXi, MQ, MQi, MR, MRi
• OC, OCA, OCB, PC, PCA, PCB, PUPE, PUPEi, TR, TRi, TX, TXi
• URMi, URMAi, URMBi
• CC, CCi, GS, GSi, ANi, ANAi, ANBi
• SMCR, SRFIL :
• COMAi, COMBi, ETAi, GXi, MQi, MRi, OCA, OCB, PCA, PCB, PUPEi
• SABAi, TRi, TXi, URMAi, URMBi
• CCi, GSi, ANAi, ANBi
• SMBCR :
• COMAi, COMBi, GXi, MQi, MRi, OCA, OCB, PCA, PCB, PUPEi
• TRi, TXi, URMAi, URMBi
• CCi, GSi, ANAi, ANBi, HDAi, HDBi, GWAi, GWBi

10 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

AF FUNCTIONAL ADDRESS OF SOFTWARE MACHINE


- Symbolic parameter name
- Possible values, according to the command:
• LDIL, LDMO : COMi
• APDLA : MRi, MRCCi
• FLUIL : PUPEi
• URSIN : URMi
• V52CR, V52IL, T2DCR, T2DIL : ANAi, ANBi
AFCC CC IDENTIFICATION NUMBER
- Symbolic name of parameter
- On the form : <UR No>-<CC No>
AFCMD FUNCTIONAL ADDRESS OF CONTROL UNIT
- Symbolic name of parameter
AFCN DIGITAL CONCENTRATOR FUNCTIONAL ADDRESS
- Symbolic name of parameter
- The parameter is in the form <UR> - <CN nº> with :
- 1 ≤ UR ≤ 251
- 0 ≤ CN ≤ 20.
AFCN FUNCTIONAL ADDRESS OF MAIN DIGITAL CONCENTRATOR
- Symbolic name of parameter
- In the form : <UR> - <nº CN>
- 1 ≤ UR ≤ 251
- 0 ≤ CN ≤ 20
AFCNP FONCTIONAL ADDRESS OF THE UTP CN
- Symbolic name in output lists
AFCR FUNCTIONAL ADDRESS OF A BACK CIRCUIT
- Symbolic name of parameter
- On the form :
- <UR>-<PCM>-<PCM channel> as parameter
- or <UR>-<EQU> printed out
• UR : connection unit number,
• 1 ≤ UR ≤ 223
• PCM : 0 ≤ PCM ≤ 3 on SMT1G
• 0 ≤ PCM ≤ 15 on SMT2G
• PCM channel : 1 ≤ PCM channel ≤ 31
• EQU : equipment number ( = 32 * PCM + PCM channel)

3BW 45305 AAAA RKAHA Ed. 07 11 / 236


SYMBOL DICTIONARY

AFCT FUNCTIONAL ADDRESS OF A CIRCUIT


- Symbolic name of parameter
- On the form :
- <UR>-<PCM>-<PCM channel> as parameter
- or <UR>-<EQU> printed out
• UR : connection unit number,
• 1 ≤ UR ≤ 223
• PCM : 0 ≤ PCM ≤ 3 on SMT1G
• 0 ≤ PCM ≤ 127 on SMT2G or SMB_T
• PCM channel : 1 ≤ PCM channel ≤ 31
• EQU : equipment number ( = 32 * PCM + PCM channel)
AFCTD FUNCTIONAL ADDRESS OF O/G CIRCUIT GROUP SUBSECTION
- Symbolic name of parameter
- Same semantics as AFCT
AFCTE FUNCTIONAL ADDRESS OF I/C TERMINAL CIRCUIT
- Symbolic name of parameter
- Same semantics as AFCT
AFCTE FUNCTIONAL ADDRESS OF I/C TERMINAL CIRCUIT
- Symbolic name of parameter
- Same semantics as AFCT
AFCTI FUNCTIONAL ADDRESS OF CIRCUIT IDENTIF. SECTION
- Symbolic name of parameter
- Same semantics as AFCT
AFCTS FUNCTIONAL ADDRESS OF O/G TERMINAL CIRCUIT
- Symbolic name of parameter
- Same semantics as AFCT
AFD FUNCTIONAL ADDRESS OF DESTINATION SOFTWARE MACHINE
- Symbolic parameter name
- Possible values :
• MQi, TRi, TXi
• ALL
• Allows all MLs carrying the archive to be identified.
AFEC ADDRESS OF SIGNAL AND MEASURING TONE TEST EQUIPT.
- Symbolic name of parameter
- On the form <UR>-<EQPT>, with :
• UR : connection unit (from 1 to 251),

12 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• EQPT : equipment number (from 1 to 5119).


AFF CONTRACT DATA
- Parameter value
AFGRA FUNCTIONAL ADDRESS OF AN SMA LR GROUP
- Symbolic parameter name
- In the form <sma>-<glr> :
- <sma> SMA number (1 ≤le glr ≤le 64)
- <glr> Rank of the GLR in the SMA (= 0)
AFGRT FUNCTIONAL ADDRESS OF AN SMT LR GROUP
- Symbolic parameter name
- In the form <smt>-<glr>
- <smt> SMT number (1 ≤le smt ≤le 64)
- <glr> Rank of the GLR in the SMT (0 ≤le glr ≤le 3 if SMT1G)
- (0 ≤le glr ≤le 15 if SMT2G)
AFGRU FUNCTIONAL ADDRESS OF A CSNL LR GROUP
- Symbolic parameter name
- In the form <ur>-<glr>
- <ur> Number of CSN connection unit (1 ≤le ur ≤le 223)
- <glr> Rank of the GLR in the connection unit (0 ≤le glr ≤le 1)
AFGRX FUNCTIONAL ADDRESS OF A MATRIX LINK GROUP AT THE SWITCHING MATRIX SYS-
TEM LEVEL
- Parameter symbolic name
- On RCX, RCH/HC2 network: in the form <com>-<glr>
- <com> COM number (1 to 8 on SMX or 1 to 16 on RCH)
- <glr> GLR rank in the station (0 to 31 on SMX or 0 to 63 on RCH)
- On RCH network : in the form <narca>-<glr>
- <narca> Access number in the ATM network (1 to 128)
- <glr> GLR rank on the TCA (0 to 15)
AFI PERMANENT TRANSFER
- Value of parameter MAR
AFLR FUNCTIONAL ADDRESS OF CX LINE AT UR LEVEL
- Symbolic name of parameter
- In the form <UR No.> - <LR No.> with :
• UR : connection unit
• LR : 0 ≤ LR ≤ 3 for the CSED or the URA2G
• : 0 ≤ LR ≤ 15 for the CSN or the UR AN
• : 0 ≤ LR ≤ 3 for the IRM (SMT1G)

3BW 45305 AAAA RKAHA Ed. 07 13 / 236


SYMBOL DICTIONARY

• : 0 ≤ LR ≤ 127 for the IRM (SMT2G or SMBT)


AFLR FUNCTIONAL ADDRESS OF PCM AT UR LEVEL
- symbolic name of parameter
- on the form : <No UR>-<No LR> with
- 1 ≤ UR ≤ 223
- 0 ≤ LR ≤ 15 for the CSN or the UR AN
- 0 ≤ LR ≤ 3 for the CSE
AFLRE FUNCTIONAL ADDRESS OF CX LINE AT THE I/C UR LEVEL
- Symbolic name of parameter
- Same semantics as AFLR
AFLRI FUNCTIONAL ADDRESS OF NETWORK LINE AT CSN LEVEL
- Symbolic name of parameter
- The parameter is in the form <UR>-<CN>-<LRI>
• UR : connection unit (CSN) (from 1 to 251)
• CN : digital concentrator (from 0 to 20),
• LRI : internal network line (from 0 to 3).
AFLRM FUNCTIONAL ADDRESS OF CX LINE AT THE I/C UR LEVEL
- Symbolic name of parameter
- AFLRM = UR (IRS) - LRM
• UR : UR number of the module of the URM connecting the URAD to the exchange
• LRM: Number of the PCM of the IRS connecting the URAD to the exchange
AFLRS FUNCTIONAL ADDRESS OF CX LINE AT THE O/G UR LEVEL
- Symbolic name of parameter
- Same semantics as AFLR
AFLRX FUNCTIONAL ADDRESS OF A MATRIX LINK AT THE SWITCHING MATRIX SYSTEM LEVEL
- Parameter symbolic name
- On RCH network : in the form <narca>-<glrx>
- <narca> Access number in the ATM network (1 to 128)
- <lrx> LR rank on the TCA (0 to 127)
- On RCX network : in the form <com>-<glrx>
- <com> Access number on exchange (1 to 32)
- <lrx> LR rank on exchange (0 to 255)
AFLRXE FUNCTIONAL ADDRESS OF I/C LR LINK AT SWITCHING NETWORK
- Symbolic name printed out
- On RCX and RCH/HC2 switching network : in the form <com>-<lrx>
- <com> COM number (from 1 to 8 on SMX or from 1 to 4 on RCH)

14 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- <lrx> Rank of the LRX (from 0 to 255)


- On RCH switching network : in the form <narca>-<lrx>
- <narca> Access number in ATM network (from 1 to 128)
- <lrx> Rank of the LRX (from 0 to 127)
AFLRXS FUNCTIONAL ADDRESS OF O/G LR LINK AT SWITCHING NETWORK
- Symbolic name printed out
- On RCX and RCH/HC2 switching network : in the form <com>-<lrx>
- <com> COM number (from 1 to 8 on SMX or from 1 to 4 on RCH)
- <lrx> Rank of the LRX (from 0 to 255)
- On RCH switching network : in the form <narca>-<lrx>
- <narca> Access number in ATM network (from 1 to 128)
- <lrx> Rank of the LRX (from 0 to 127)
AFO CALL BACK : CIRCUIT GROUP BUSY
- Value of parameter MAR (CENTREX)
AFPIL FUNCTIONAL ADDRESS OF DUPLICATE UR LOGIC
- Symbolic name of parameter
- On the form <UR No.>
- B0, B1 (posit. of duplicate logic units)
AFRES DUPLICATE STANDBY LOGIC FUNCTIONAL ADDRESS
- Symbolic name of parameter
- The parameter is in the <UR> form
AFRES STANDBY LOGIC FUNCTIONAL ADDRESS
- Symbolic name of parameter
AFRM FUNCTIONAL ADDRESS OF PCM RANK AT UR LEVEL
- Symbolic name of parameter
- On the form <UR No.>-<I/C PCM rank>
• UR : connection unit,
• <PCM rank> : included between 0 and 3.
AFRME FUNCTIONAL ADDRESS OF I/C PCM RANK AT THE UR LEVEL
- Symbolic name of parameter
- Same semantics as AFRM
AFRMS FUNCTIONAL ADDRESS OF O/G PCM RANK AT THE UR LEVEL
- Symbolic name of parameter
- Same semantics as AFRM
AFS FUNCTIONAL ADDRESS OF SOURCE SOFTWARE MACHINE
- Symbolic parameter name

3BW 45305 AAAA RKAHA Ed. 07 15 / 236


SYMBOL DICTIONARY

- Possible values :
• MQi, TRi, TXi
AFSEM FUNCTIONAL ADDRESS OF COMMON CHANNEL
- Symbolic name of parameter
- On the form <UR No.>.
- B0, B1 : common channel positionning
- Use in AFSEM of IRS and URAD values :
• IRS : the end which is concerned is the local end
• URAD : the end which is concerned is the remote end (Remote subscriber UR)
AFTSX FUNCTIONAL ADDRESS OF SIGNALLING TERMINAL
- Symbolic name output
- On RCX and RCH/HC2 switching network : in the form <com>-<lrx>-<it>
- <com> COM number (from 1 to 8 on SMX or from 1 to 4 on RCH)
- <lrx> Rank of the LRX (from 0 to 255)
- <it> IT number (from 0 to 30)
- On RCH switching network : in the form <narca>-<lrx>-<it>
- <narca> Access number in ATM network (from 1 to 128)
- <lrx> Rank of the LRX (from 0 to 127)
- <it> IT number (from 0 to 30)
AFUR FUNCTIONAL ADDRESS OF CONNECTION UNIT
- Symbolic name of parameter
- On the form : <UR No.>
AFUR FUNCTIONAL ADDRESS OF CONNECTION UNIT
- Symbolic name of parameter
- On the form : <UR No.>
AFVT FUNCTIONAL ADDRESS OF TIME DIVISION CHANNEL
- Symbolic name of parameter
- On the form <UR>-<LR>-<VT>
- Where 1 ≤ UR ≤ 251
- 0 ≤ LR ≤ 3
- 0 ≤ VT ≤ 31
AFVTC FUNCTIONAL ADDRESS OF TIME DIVISION CHANNEL
- Symbolic name printed out
- On the form <UR>-<LR>-<VT> (current AFVT)
AFVTE FUNCTIONAL ADDRESS OF TIME DIVISION CHANNEL
- Symbolic name of parameter

16 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Same semantics as AFVT.


AFVTE FUNCTIONAL ADDRESS OF TIME DIVISION CHANNEL
- Symbolic name of parameter
- Same semantics as AFVT.
AFVTS FUNCTIONAL ADDRESS OF O/G TIME DIVISION CHANNEL
- Symbolic name of parameter
- Same semantics as AFVT.
AFXMC FUNCTIONAL ADDRESS OF TIME SLOT FOR AN XMCB CARD
- Symbolic name of parameter
- <UR>-<No COUPLE XMCB>
AG RANK OF AN AGENT IN AN SM
- Symbolic parameter name
- Possible values : 0 to 15
- Rank of the agent on the BSM bus
AGCA PHYSICAL ADDRESS OF BOARD
- Output symbolic name
- In the form S<s>-TR<t>-B<b>-A<a>-R<r>
• For an SM board
• <s> Room (1 ≤le s ≤le 9)
• <t> Row (1 ≤le t ≤le 99)
• <b> Rack (1 ≤le b ≤le 99)
• <a> Subrack located by its level (1 ≤le b ≤le 190)
• <r> Slot (0 ≤le b ≤le 154)
• For a CSNL board
• <s> Room (1 ≤le s ≤le 9)
• <t> Row (1 ≤le t ≤le 99)
• <b> Rack (1 ≤le b ≤le 99)
• <a> Subrack (1 ≤le b ≤le 5)
• <r> Slot (0 ≤le b ≤le 154)
AGDE PART ONE OF THE CALLED PARTY GLOBAL ADDRESS
- Symbolic name of parameter in the form of (a - b -c)
- -a Type of translation possible value from 0 to 255
- -b Numbering scheme possible value from 0 to 15
- -c Nature of the address possible value from 0 to 127
AGDR PART ONE OF THE CALLING PARTY GLOBAL ADDRESS
- Symbolic name of parameter in the form of (a - b -c)

3BW 45305 AAAA RKAHA Ed. 07 17 / 236


SYMBOL DICTIONARY

- -a Type of translation possible value from 0 to 255


- -b Numbering scheme possible value from 0 to 15
- -c Nature of address possible value from 0 to 127
AGEO GEOGRAPHICAL ADDRESS OF A REMOTE SITE
- Symbolic name of parameter
- Name of remote site (URAD,CNE)
AGEO PHYSICAL ADDRESS OF CONTROL STATION
- Output symbolic name
- In the form S<s>-TR<t>-B<b>-A<a>-R<r>
- <s> Room (1 ≤le s ≤le 9)
- <t> Row (1 ≤le t ≤le 99)
- <b> Rack (1 ≤le b ≤le 99)
- <a> Subrack located by its level (1 ≤le b ≤le 190)
- Level of the subrack containing the main coupler
- <r> Slot (0 ≤le b ≤le 154)
- Slot for the first board comprising the SM
AGEO CONTROL STATION GEOGRAPHIC ADDRESS
- Symbolic name printed out
- In the form S<s>-TR<t>-B<b>-A<a>-R<r>
• <s> Room (1 ≤ s ≤ 9)
• <t> Row (1 ≤ t ≤ 99)
• <b> Rack (1 ≤ b ≤ 99)
• <a> Subrack identified by its level (1 ≤ a ≤ 190)
- Level of subrack supporting the main coupler
• <r> Slot (0 ≤ r ≤ 154)
- Slot of the first board belonging to the SM
AHP01 UT HAVING 1 ISDN EQUIPMENT WITH PRIMARY RATE ACCESS CAPABILITY CRC4
(HDSL)
- Value of parameter
AIDR IDENTITY ARRANGEMENT OF THE CALLING PARTY
- Value of the CAT parameter
AIPBC IP ADDRESS OF THE OCB NETWORK
- Parameter symbolic name
- In the form <aaa>-<bbb>-<ccc>-<ddd>
- <aaa> (0 ≤ aaa ≤ 255)
- <bbb> (0 ≤ bbb ≤ 255)
- <ccc> (0 ≤ ccc ≤ 255)

18 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- <ddd> (0 ≤ ddd ≤ 255)


AIPPC MAIN IP ADDRESS ON THE LSN
- Parameter symbolic name
- In the form <aaa>-<bbb>-<ccc>-<ddd>
- <aaa> (0 ≤ aaa ≤ 255)
- <bbb> (0 ≤ bbb ≤ 255)
- <ccc> (0 ≤ ccc ≤ 255)
- <ddd> (0 ≤ ddd ≤ 255)
AIPSC SECONDARY IP ADDRESS ON THE LSN
- Parameter symbolic name
- In the form <aaa>-<bbb>-<ccc>-<ddd>
- <aaa> (0 ≤ aaa ≤ 255)
- <bbb> (0 ≤ bbb ≤ 255)
- <ccc> (0 ≤ ccc ≤ 255)
- <ddd> (0 ≤ ddd ≤ 255)
AJND RECORDING OF (NAR or NAI) +PREF+ND
- Symbolic name of parameter
- Possible value : YES or NO (implicit value)
- Parameter present and "YES" value : Recording of subscriber’s ND and possible prefix
(area code) in addition to the call forwarding NAR or immediate routing number NAI.
- Parameter absent or "NO" value : Recording of NAR or NAI alone.
AL ASYNCHRONOUS LINE
- Symbolic name of parameter
ALA FILTER ON SERVICES WITH ALARMS
- Parameter symbolic name
- Possible value: YES, NO.
ALA PRINTOUT OF REQUIRED ALARMS
- Symbolic name of parameter
- O (yes) or N (no). NO by default
ALA$$2 ABNORMAL NT1(Digital Network Termination)POWER SUPPLY
- Symbolic parameter name
- Digital subscriber
ALA ETU ALARM CONDITION
- Symbolic name of parameter
- YES or NO
ALAFI PRINTOUT OF REQUIRED MULTI-LINE TRANSMISSION ALARMS
- Symbolic name of parameter

3BW 45305 AAAA RKAHA Ed. 07 19 / 236


SYMBOL DICTIONARY

- O (yes) or N (no). NO by default


ALL MAGTAPE MOUNTED WITH OR WITHOUT EXTENSION OPTION
- Symbolic name of parameter
- Possible values : O (yes) or N (no)
• ALL = 0 New file written on the tape
• next to last file of the tape
• ALL = N (Implicit Option) New file written
• on the tape next to labels placed at the beginning of the volume
• (replacement of old files).
ALL COMPUTATION ON FILE CHECKSUM
- Symbolic name of parameter.
ALL OPTIONAL START OF TRANSACTION STATISTICS OUTPUT
- Symbolic name of parameter
ALL ALL FILES REGARDLESS OF TYPE
- Parameter value
ALL ALL ARCHIVE CARRIERS
- Parameter value
ALL LISTING FOR ALL EXCHANGES
- Symbolic name of parameter
- No assignable value
- Used with the RHM INFIL, it enables the listing of all terminal entitlements in all ex-
changes on a site regardless of the number exchanges declared in the BKCN file.
ALONE STAND ALONE OM INITIALIZATION
- Parameter value
This mode allows the OM to be started up alone without connecting it to the OCB
command. All resources of OM function are available except access to and operation
of the OCB.
This initialization option is reserved for future use.
ALRIX LRI FUNCTIONAL ADDRESS ON THE UCX
- Symbolic name of parameter
- On the form <UR>-<LRIX> with :
• UR : CSN connection unit,
• LRIX : number of the UCX end of the CSN, value from 2 to 47.
ALRXE FUNCTIONAL ADDRESS OF CX INPUT LINE AT SWITCHING NETWORK LEVEL
- Symbolic name of parameter
- On RCX and RCH/HC2 switching network : in the form <com>-<lrx>
- <com> COM number (from 1 to 8 on SMX or from 1 to 4 on RCH)

20 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- <lrx> Rank of the LRX (from 0 to 255)


- On RCH switching network : in the form <narca>-<lrx>
- <narca> Access number in ATM network (from 1 to 128)
- <lrx> Rank of the LRX (from 0 to 127)
ALRXS FUNCTIONAL ADDRESS OF CX OUTPUT LINE AT SWITCHING NETWORK LEVEL
- Symbolic name of parameter
- On RCX and RCH/HC2 switching network : in the form <com>-<lrx>
- <com> COM number (from 1 to 8 on SMX or from 1 to 4 on RCH)
- <lrx> Rank of the LRX (from 0 to 255)
- On RCH switching network : in the form <narca>-<lrx>
- <narca> Access number in ATM network (from 1 to 128)
- <lrx> Rank of the LRX (from 0 to 127)
ALS Automatic laser shutdown
- Symbolic name of parameter
- It can take following values :
• YES
• NO
ALTF ACTIVE GROUP OF SERVICES
- value of parameter MAR
ALV SHELF LEVEL
- Symbolic name printed out
- Decimal integer (on 3 figures)
AMn ADJONCTION OR MODIFICATION OF FIGURES
- Value of parameter DIS
- The first "n" figures of the analysed number
- are replaced by parameter IND figures (0 < n < 15)
AM NAME OF MULTIPROCESSOR STATION
- Symbolic name of parameter.
- Possible values : SMTi, SMBDi
AM HARDWARE ADDRESS OF A CONTROL STATION
- Parameter symbolic name
- Possible values according to the command:
• AMXIL, DMPMO, ESMIN, ETUIL, ETUIN, FFIMO, IDLIN, SRFIL
• SCH, SCHi, SCHAi, SCHBi, SMA, SMAi, SMC, SMCi, SMM, SMMA, SMMB,
• SMT, SMTi, SMTAi, SMTBi, SMX, SMXi, SMXAi, SMXBi, SMB, SMBi
• AMXMO, ARCIN, ARCMO, DMPLA, ESMMO, FEMAR, FEMIL, FEMLA, MAPIL,
SMTL

3BW 45305 AAAA RKAHA Ed. 07 21 / 236


SYMBOL DICTIONARY

• SCHAi, SCHBi ,SMAi, SMCi, SMMA, SMMB, SMTAi, SMTBi, SMXAi, SMXBi,
• SMBi
• SMCR, SMSU
• SAMi, SCHAi, SCHBi, SMAi, SMCi, SMMA, SMMB, SMTAi, SMTBi, SMXAi,
• SMXBi, STHi, STS, SZHi
• AMPCR
• SMMA, SMMB
• ETUCR, ETUMO, ETUSU, ETUTL, OCAGE, OCPRO
• SCHi, SCHAi, SCHBi, SMMA, SMMB, SMCi, SMXi, SMXAi, SMXBi, SMBi,
• SMAi, SMTi, SMTAi, SMTBi, SMBAi, SMBBi, SMBDi
• SMIL
• SCH, SCHi, SCHAi, SCHBi, SMA, SMAi, SMC, SMCi, SMM, SMMA, SMMB,
• SMT, SMTi, SMTAi, SMTBi, SMX, SMXi, SMXAi, SMXBi, SAMi, SDIVi,
• STS, SZHi
• CNFCR, CNFSU, SMBCR, SMBSU, CNFMO, RESMO, CFAMO, HMXMO
• SMBi
• ETUIL, ETUIN
• SMBAi, SMBBi, SMBDi
• OCPLA
• SMB, SMBi, SMBAi, SMBBi, SMBD, SMBDi
AMET HARDWARE ADDRESS OF PCM LINK AT CDC END (SMT2G)
- Symbolic name of parameter
- The value is specified in the form : <SMT No.>-<RGTU No.>-<RGET No.>
- The SMT number is comprised between 1 and 32
- The RGTU number is comprised between 1 and 32
- The RGET number is comprised between 1 and 4
AMETU ETU HARDWARE ADDRESS
- Symbolic name of parameter
- The setting is in the form <RGSM>-<RGTU>
- <RGSM> : PCM termination multiprocessor station number from
- 1 to 64
- <RGTU> : Termination equipment board number from
- 1 to 32
AMH HARDWARE ADDRESS OF HUB TR SUPPORT SMB
- Parameter symbolic name
- Possible values: AMH = SMBi

22 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

AMTRA Modification of carrier number authorized for the traffic A


- Value of parameter CAT
AMTRB Modification of carrier number authorized for the traffic B
- Value of parameter CAT
AMTRC Modification of carrier number authorized for the traffic C
- Value of parameter CAT
AMV MARK OF DO-NOT-DISTURB FACILITY
- Value of parameter MAR
AMX HARDWARE ADDRESS OF A RING IN A COMMUNICATION MULTIPLEX
- Parameter symbolic name
- Possible values according to the command:
• AMXIL :
• MAS, MASi, MASAi, MASBi, MIS, MISA, MISB
• AMXMO, HMXMO :
• MASAi, MASBi, MISA, MISB
ANi NETWORK ACCESS
- Value of parameter TYAN
- Value of i between 1 and 2
- AN1 : Type-1 AN (without signalling combination)
- AN2 : Type-2 AN (with signalling combination)
AN ML AN
- TYML parameter value
ANAi i ACCESS NETWORK ML, SUBSYSTEM A
- Parameter value ( 1 <= i <= 16 )
ANA NATIONAL ANALYSIS
- Value of parameter
ANBi i ACCESS NETWORK ML, SUBSYSTEM B
- Parameter value ( 1 <= i <= 16 )
AND ND-ACH ASSOCIATION
- Output value of parameter MAR
ANDL NATURE OF THE LIST NDL
- Symbolic name of parameter
- Input possible values : I or N ( Implicit value N).
- Output possible values : I, N or *
ANO MALFUNCTION RECORD PRINTOUT
- Symbolic name of parameter

3BW 45305 AAAA RKAHA Ed. 07 23 / 236


SYMBOL DICTIONARY

- Type for magnetic tape read


ANR NUMBER OF CALLS TERMINATED ON NO ANSWER
- Symbolic name printed out
ANS SUBSCRIBER NOT RUNG
- CAT parameter value
ANX AUXILLIARY MODULES IN CASE CONCENTRATOR
- Value of parameter
AONS ACTIVE-OPERATIONAL-NOT BACKED UP
- Symbolic name in output list
- This status implies that the SMM station works in SIMPLEX mode.
AOS ACTIVE-OPERATIONAL-BACKED UP
- Symbolic name in output list
- This status allows the SMM station to work in DUPLEX mode.
AOT NUMBER OF CALLS ENDING UPON ALL JUNCTIONS BUSY
- Output symbolic name
AOTCM ATM-SDH-STM1-ATC optical applique
- PRF parameter value
AO1S ATM-SDH-STM1-IWU optical applique
- PRF parameter value
APE INCOMING CALL IN CUG AUTHORIZED
- Value of the CAT parameter
APEF NUMBER OF COMPLETED TERMINATING CALLS
- Output symbolic name
APOB PHYSICAL ADDRESS OF SATELLITE ALARM COUPLER
- Output symbolic name
- Possible values 1 to 512
APP OBSERVATION OF CALL DISPERSION
- Value of parameter TYOBS
APP TYPE OF CALL SET UP
- Symbolic name during processing
- Outputed at the time of a magnetic tape of the itemized billing type
- Possible values:
• I: immediate call processing
• D: delayed call processing
APS OUTGOING CALL FROM THE CUG AUTHORIZED
- Value of the CAT parameter

24 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

APU CALL PRESUMED TO BE URGENT


- Parameter value
- Parameter : DIS
AQA04 UT HAVING 4 ADSL DIGITAL EQUIPMENT UNITS (2B1Q-AE) W/2 WIRES
- Value of parameter
AQE08 UT HAVING 8 EQUIPMENT UNITS (2B1Q) W/2-WIRES AND ECHO-CANCELLATION
- Value of parameter
AQP08 UT HAVING 8 EQUIPMENT UNITS (2B1Q) W/2-WIRES AND ECHO-CANCELLATION
- Value of parameter
AR PHYSICAL ADDRESS OF STATION SECOND PART
- Symbolic parameter name
- In the form <a>-<r>
- <a> Subrack located by its level (1 ≤le b ≤le 190)
- Level of the subrack containing the main coupler
- <r> Slot (0 ≤le b ≤le 154)
- Slot for the first board comprising the SM
ARA ARAB CHARACTER TYPE
- Value of the CAR parameter of commands LASCR, LASMO
ARBM PHYSICAL ADDRESS OF MAGNETIC TAPE DRIVE SECOND PART
- Symbolic parameter name
- In the form <a>-<r>
- <a> Subrack located by its level (1 ≤le b ≤le 190)
- <r> Slot (0 ≤le b ≤le 154)
ARC BARRED ACCESS FACILITY ACTIVATED
- Symbolic name of parameter
ARC OUTPUT AT THE ARCHIVE LEVEL
- Parameter value
ARC OUTPUT ON ARCHIVE LEVEL
- Parameter value
ARCH ARCHIVE LOGO
- Symbolic parameter name
- Possible values for the following commands :
• ARCCO, ARCIN, ARCMO, ARCRG, ARCSU, ARCSV, IDLIN :
- ZSM Permanent archive of the generic SM software
- ZMR Permanent archive of the MR ML
- ZTX Permanent archive of the TX ML

3BW 45305 AAAA RKAHA Ed. 07 25 / 236


SYMBOL DICTIONARY

- ZTR Permanent archive of the TR ML


- ZMQ Permanent archive of the MQ ML
- ZETA Permanent archive of the ETA ML
- ZCOM Permanent archive of the COM ML
- ZCOM2 Permanent archive of the COM2G ML
- ZURM Permanent archive of the URM ML
- ZURM2 Permanent archive of the URM2G ML
- ZOC Permanent archive of the OC ML
- ZGX Permanent archive of the GX ML
- ZCC Permanent archive of the CC ML
- ZGS Permanent archive of the GS ML
- ZLO Permanent archive of the LOCAVAR
- ZLI Permanent archive of bind
- ZCSN0 Permanent archive of the CSN
- ZCSN1 Permanent archive of the CSN
- ZCSH0 Permanent archive of the CSN HD
- ZCSH1 Permanent archive of the CSN HD
- ZSABA Permanent archive of the SABA ML
- ZBUS Permanent archive of transport
- ZOTD Permanent archive of the data processing tool
- XAFO Archive of the OM files
- XASM Semi-permanent archive of the generic SM software
- XATX Semi-permanent archive of the TX ML
- XATR Semi-permanent archive of the TR ML
- XAMQ Semi-permanent archive of the MQ ML
- XUTC Semi-permanent archive of the PUPE ML and the PC ML
• ESYMO :
- <same list as for ARCIN> plus:
- STD all archives with a working area
• SITRG :
- <same list as for ARCIN> plus:
- ALL all archives present on tape
ARCHD NAME OF DESTINATION ARCHIVE
- Symbolic parameter name
- Possible values : see ARCH
ARCHS NAME OF SOURCE ARCHIVE

26 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic parameter name


- Possible values : see ARCH
ARCSN CSN STORAGE
- Symbolic name of parameter
- Possible value : from 0 to 1
ARD TYPE OF EQUIPMENT CONNECTED TO THE OM
- Value of parameter.
ARDS TYPE OF EQUIPMENT CONNECTED TO THE OM
- Value of parameter.
AREn RECEIVE ATTENUATION
- Value of parameter : TY
- Possible values : 1 < n < 3
ARFN PRESET CALL FORWARDING IF NO ANSWER
- Value of parameter MAR
ARFO PRESET CALL FORWARDING IF LINE BUSY
- Value of parameter MAR
ARFT UNCONDITIONAL PRESET CALL FORWARDING
- Value of parameter MAR
ARL AUTOMATIC CALL BACK : STATION BUSY
- Value of parameter MAR
ARN CALL FORWARDING UPON NO ANSWER
- Value of MAR parameter
ARO CALL FORWARDING IF LINE BUSY
- Value of parameter MAR
ARQ ISDN EQUIPMENT WITH 4-WIRE BASIC ACCESS AND REPEATER CAPABILITY
- Output symbolic name
ARQ04 UT HAVING 4 ISDN EQUIPMENTS WITH 4-WIRE BASIC ACCESS AND REPEATER CAPA-
BILITY
- Value of parameter
ART SUBSCR. HAVING ACTIVATED TEMPORARY CALL FORWARDING
- Value of parameter MAR
ARV SUBSCR. HAVING ACTIVATED AUTOMATIC WAKE-ME SERVICE
- Value of parameter MAR
ARV NUMBER OF CALLS TRANSFERRED
- Output symbolic name
AS Automatic switch
- Value of the parameter REQ

3BW 45305 AAAA RKAHA Ed. 07 27 / 236


SYMBOL DICTIONARY

AS FILE ATTRIBUTED
- Symbolic name printed out
ASA CALLING LINE IDENTITY RESTRICTION ALLOWED FOR A SINGLE CALL
- Value of the CAT parameter
ASD DIRECT INPUT DIALLING INSTALLATION
- Value of parameter MAR
ASE1 FIRST STAGE OF THE ATM SWITCHING NETWORK
- Parameter value
ASE2 SECOND STAGE OF THE ATM SWITCHING NETWORK
- Parameter value
ASG ADDRESS OF THE EXTERNAL GROUP
- Symbolic name printed out
ASI UNDER SUPERVISION-SUPPLY NOT POSSIBLE
- Symbolic name output or symbolic name of parameter
- digital subscriber
ASM SIGNALLING ROUTING
- Symbolic name of parameter
- Possible value : from 1 to 63 if TYR=RN (national network)
- : from 65 to 127 if TYR=RL (local network)
- : 64 (utility ASM)
ASO PSTN CALL : WAIT ON CALLED PARTY BUSY
- Value of parameter : CAT
ASS SCCP ROUTING NUMBER
- Symbolic name of parameter
- Possible value from 1 to 31
AST TERMINAL ASSIGNMENTS AND ALLOCATIONS
- Value of parameter
ATn ROUTING AND METERING CATEGORY
- Parameter value
- Possible value : 1 ≤ n ≤ 32
ATT ACTIVATION INDICATION FOR A CALL ON
- Value of parameter MAR
AUB NOISE MEASUREMENT AUTHORIZATION (PSOPHOMETER)
- Value of parameter CTA
AUD CHARGING AUDIT RECORD
- Value of parameter

28 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Type for magnetic tape read


AUT OUTPUT ACCORDING TO FORMAT ASSOCIATED WITH STRUCTURE
- Parameter value
AUTS ENABLES BACKUP OF CONTROL STATION
- Symbolic parameter name
- Possible values : YES or NO
- If AUTS = YES, the functions of the SM are automatically transferred to the standby
SM if the SM fails or is manually isolated.
AUX Service circuit type
- Symbolic parameter name
- Value from 1 to 31
AUX AUXILIARY COUPLER
- SFCA parameter value
AUX2 2XICL/ISL PQUICC PROCESSOR ON AUX COUPLER
- SFEM parameter value
AUX3 3XICL/ISL PQUICC PROCESSOR ON AUX COUPLER
- SFEM parameter value
AV VALUE TO ADD TO CENTRAL TIME TO CLOCK RESETTING
- Symbolic name of parameter
- On the form <hour>-<minute>-<second>
AV VALUE TO ADD TO CENTRAL TIME TO CLOCK RESETTING
- Symbolic name of parameter
- On the form <hour>-<minute>-<second>
• hour included between 00 and 23
• minute included between 00 and 59
• second included between 00 and 59
AVGMT advance standard time compared to hour GMT
- Symbolic name of parameter
- On the form <hour>-<minute>-<second>
- Possible values for <minute> : 00 or 30
AXF Routing towards auxiliary trunk group
- Value of parameter STY
B POSSIBLE RECEPTION STATUS ON A BUS
- Value of parameter
B INTERNAL BLOCKING
- Value of parameter
B BRANCH B OF THE SWITCHING MATRIX SYSTEM

3BW 45305 AAAA RKAHA Ed. 07 29 / 236


SYMBOL DICTIONARY

- Possible value for the BRCX parameter


B RACK NUMBER FOR AN OBJECT LOCATED AT A SITE
- Symbolic name of parameter
Bi TYPE B
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15
BAIE RACK NUMBER
- Symbolic name printed out
BAN ASSIGNMENTS OF GENERAL PURPOSE LFN.
- Value of parameter
BASC EQUIPMENT TRANSFER
- Symbolic name of parameter
- Possible values : A, B, N (Normal), S (Standby), B0, B1.
BASC SWITCH OVER OF CDC TO PN+X
- Parameter value
- Used for an incompatible release change, the switchover to Pn+x includes:
• The positioning of the "ACTIVE MONITORS" of the multiplexes.
• The switchover of the OM function
• The Pn+x release then becomes the reference.
• The halting of the stations of Subsystem B (Pn).
• The switchover of the traffic on the stations of Subsystem A (Pn+x).
- Switchover to Pn+x must be carried out after the broadcasting of data in Subsystem
A.
BASE CORRECTION METHOD APPLIED TO SIGNALLING TERMINALS CORRESPONDING BA-
SIC METHOD
- Value of parameter
BASE ANALYSIS OF TAPE BASE CONTENT
- Value of parameter
BBUCR OM INITIALIZATION IN ISOLATED MODE
- Parameter value
This mode allows the OM to be started up for the purposes of exchange data gener-
ation. The OM operates with a simulation LCC and some specific transactions.
This initialization option is saved for future use.
BED SUPPLY BY BATTERY
- Symbolic name output or symbolic name of parameter
- digital subscriber
BI POSITIVE LOWER LIMIT OF A LINE CALIBER CHARACTERISTIC

30 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- Value depending on the characteristic number: L1 0 ≤ VALUE ≤ 254 V L2 0 ≤ VALUE
≤ 254 V L3 0 ≤ VALUE ≤ 63V L4 0 ≤ VALUE ≤ 63V L5 0 ≤ VALUE ≤ 1016 KOhms L6
0 ≤ VALUE ≤ 1016 KOhms L7 0 ≤ VALUE ≤ 1016 KOhms L8 0 ≤ VALUE ≤ 6350 nF
BITCi STATUS OF BIT C TO TRANSMIT IN TS 16 OF OUTGOING PCM
- Value of parameter AECHO
- Possible values:
- i=1 BITC transmitted at 0 (default value)
- i=2 BITC transmitted at 1
BL LIST OF BLOCK ADDRESSES CORRESPONDING TO THE TAPE AREAS TO BE COPY
- Symbolic name of parameter
BLO ISOLATED ROUTING MARK
- Value of parameter
BLOA EQUIPMENT Nº.7 MANUALLY BLOCKED AT INPUT
- Value of parameter STTUS
BLOD EQUIPMENT Nº.7 MANUALLY BLOCKED AT OUTPUT
- Value of parameter STTUS
BLOF BLOCKING CAUSED BY TRANMISSION EQUIPMENT
- Symbolic name output
BLOJ JUNCTION BLOCKING
- Symbolic name output
BLOL LOCALLY ISOLATED V5.1 ACCESS
- Value of the parameter STTUS (ETAT) of the command TELEMO
BLOL LOCALLY ISOLATED V5.x ACCESS
- Value of the parameter STTUS (ETAT) of the command ABFASE
BLOM MANUALLY BLOCKED EQUIPMENT
- Value of parameter
BLOM CONTROL STATION MANUALLY ISOLATED
- Parameter value
- Status set by MMC, modifiable by MMC.
- The SM is non-operational.
BLOM MULTIPLEX RING MANUALLY ISOLATED
- Parameter value
- The ring has been withdrawn from service by the operator; it is no longer processing
traffic.
BLOM ETU OR ET MANUALLY ISOLATED
- Parameter setting

3BW 45305 AAAA RKAHA Ed. 07 31 / 236


SYMBOL DICTIONARY

- STATUS or symbolic name in an output line


- The ETU or the ET is out of service
BLOP BLOCK ACCESS V5.x
- symbolic output name or parameter value
- status value for a analog or digital subscriber access
BLOQ EQUIPMENT (GENERAL) BLOCKING
- Symbolic name output
BLOR BLOCKING REQUEST FOR THE ACCESS V5.x
- VALUE OF MNEMONIQUE OF PARAMETER ETAT FOR COMMAND ABFASE
BLOS EQUIPMENT BLOCKED BY SYSTEM
- Symbolic name output
BLOS CONTROL STATION ISOLATED BY THE SYSTEM
- Parameter value
- Status set by the system
- The SM is non-operational. This status appears:
- Temporarily during execution of central defence processing
- In the case of SM failure, until intervention by the operator
BLOS MULTIPLEX RING NON-OPERATIONAL
- Output symbolic name
- The ring manager has declared the ring non-operational.
BLOS ISOLATED BY THE SYSTEM
- Parameter value
BLOT COMPLETE BLOCKED - PART OF ACTIVITY
- Symbolic name output
BLS SIZE OF TRANSFERRED BLOCKS
- Symbolic parameter name.
- Possible input value for the command TRFLA : 1 to 32 .
BL31 Possibility of emiting 31 numbers in one go
- Value of the CTA parameter
BM PHYSICAL NUMBER OF MAGTAPE DRIVE
- Symbolic name of parameter
BMn MAGTAPE
- Value of parameter
- BMn : 0 ≤ M ≤ 3
BM MAGTAPES STATUS
- Value of parameter

32 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- No value can be attributed


BM NUMBER OF MAGNETIC TAPE DRIVE
- Symbolic parameter name
- Possible values from 1 to 2
BM MAGTAPE
- Value of parameter.
BME TAPE UNIT WHERE INPUT TAPE HAS BEEN MOUNTED
- Symbolic name of parameter
BMS TAPE UNIT WHERE OUTPUT TAPE HAS BEEN MOUNTED
- Symbolic name of parameter
BOF POSITIONING ON START OF FILE
- Value of parameter
BRCX BRANCH OF THE SWITCHING MATRIX SYSTEM
- Symbolic parameter name
- Possible values : A or B
BS POSITIVE UPPER LIMIT OF A LINE CALIBER CHARACT.
- Symbolic name of parameter
- Same semantics as BI.
BSC BSC NUMBER
- Symbolic name of the parameter
- Possible values : 1 to 96
BSMM ALARM RELATING TO AN SMM SWITCHOVER
- Parameter value
BUR OFFICE DATA
- Parameter value
BUR EXCHANGE DATA
- Parameter value
- Semi-permanent data from the exchange archive files (except files FIAF and FCDF).
BURM "MOAB" DATA
- parameter value
- "MOAB" data from the exchange archive files (except files FIAF and FCDF).
BXT EXTENSION RACK NUMBER FOR A CSN
- Symbolic name of parameter
B0,B1 DUPLIC. LOGIC (AFPIL) OR CCS CHANN.(AFSEM) POSIT.
- Value of parameter
B1 POSIT. OF DUPLICATE LOGIC UNITS (AFPIL) OR SIGNAL. LINK SETS (AFSEM))

3BW 45305 AAAA RKAHA Ed. 07 33 / 236


SYMBOL DICTIONARY

- Parameter value
C ROUTING AUTHORIZED FOR THE CIRCUITS
- Value of the parameter DIS
C PRINTOUT CLASS OF OBSERVED TIME METERS
- Symbolic name of parameter
- Possible values : A,C,F,H,R,T,Z.
- A : auxiliaries
- C : calls
- D : frame service
- F : circuit group
- H : time schedule table
- I : IN Service
- R : path
- S : signalling messages
- T : traffic
- Z : work areas
- if ED = 0, all classes are printed out.
Ci TYPE C
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15
C CALLS
- Value of parameter
Ci NO. OF AN EXCHANGE HAVING PASSWORD COMMAND CLASSES
- Value of parameter
CA ITEM CATEGORY
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
CA ITEM CATEGORY
- Symbolic name of parameter
- Possible values:
- 01 : technical test
- 02 : itemised billing
- 03 : subscriber line supervision
- 05 : consumption check

34 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- 07 : synchronisation item
- 08 : event
- 24 : DEA
CABn CATEGORY USED FOR A CALLED PARTY
- Value of parameter CAT
- 1 ≤ n ≤ 63
CABN SUBSCRIBER CARD
- Value of parameter ENS
CACn ROUTING CATEGORY
- Value of parameter
- 1 ≤ n ≤ 64 (default value : CAC1)
CACT WORK AREAS SWITCHING TO WORK MODE
- Symbolic name of parameter
- CACT = SITE : Switch-over to site mode (exchange in operation)
- CACT = TEST : Switch-over to test mode (eg BBU generation)
CACT ACCESS OR TRANSLATION CODE
- Symbolic name output
CAD DIAL SET
- Value of parameter TY
CAL CALENDAR
- Value of parameter MAR output
CAMi MALICIOUS CALLS
- Value of parameter CAT
- 1≤i≤8
CAR Call type for Selective Reservation of Circuits (RSC)
- Value for the DIS parameter (in analysis) (between 1 and 3)
CAR CHARACTERISTICS (ROUTING)
- Symbolic name of parameter
- NTONi Tone number (i from 1 to 255)
- TYFAi Type of facility (i from 1 to 31)
- TYPUi Facility type of use (i from 1 to 15)
CAR NUMBER OF RENEWALY AUTHORIZED ON THE ROUTING
- Symbolic name of parameter
CAT CATEGORIES OF SUBSCRIBER LINES
- Symbolic name of parameter
- The possible values are the mnemonics :

3BW 45305 AAAA RKAHA Ed. 07 35 / 236


SYMBOL DICTIONARY

- AAB, ACRJ, AEN, AIDR, ANS, APE, APS, CABn, CACn, CAMn, CAXn, CFAn,
CLABn,COF, COLP, COLR, CRIn, CTn, DAAn, DABn, DAC, DADn, DA1, DCIn, DEA,
DFA, DFn, DFU, DIPA, DIU, DIU2, DMG, DND, DNR, DN1, DPND, DROC, ECT,
ECTI, FDn, FIE, FIR, GFU, GIAn, GPRF, IAI, IAM, IAMT, IDAI, IDB, IDC, IDT, INSP, INT,
IROC, ISTA, LAI, LAT, LATF, LNP, LST, NAn, NATn, NLAn, NLBn, NMU, ORAS, OSID,
PIN, POC, PRV, RAIN, RAL, RDA, RFNR, RVFO, RVFT RVO, RVT, RVTI, SIDR, SIRAn,
SIRV, SND, SONn, SRAn, SRC, SRE, SRS, SVO, TRAn, TRBn, TRCn, TTXN, ZGn, ZTXn.
- with :
- CABn = 1 ≤ n ≤ 63
- CACn = 1 ≤ n ≤ 64
- CAMn = 1 ≤ n ≤ 8
- CAXn = 1 ≤ n ≤ 64
- CFAn = 1 ≤ n ≤ 3
- CLABn= 1 ≤ n ≤ 4
- CRIn = 1 ≤ n ≤ 32
- CTn = 1 ≤ n ≤ 32
- DAAn = 1 ≤ n ≤ 15
- DABn = 1 ≤ n ≤ 3
- DADn = 1 ≤ n ≤ 15
- DCIn = 1 ≤ n ≤ 5
- DFn = 1 ≤ n ≤ 31
- FDn = 1 ≤ n ≤ 7
- GIAn = 1 ≤ n ≤ 4095
- NAn = 1 ≤ n ≤ 16
- NATn = 1 ≤ n ≤ 2
- SIRAn= 1 ≤ n ≤2
- SRAn = 1 ≤ n ≤ 65535
- TRAn = 1 ≤ n ≤ 9999
- TRBn = 1 ≤ n ≤ 9999
- TRCn = 1 ≤ n ≤ 9999
- ZGn = 1 ≤ n ≤ 255
- ZTXn = 1 ≤ n ≤ 128
CAT SERVICE CATEGORY
- Symbolic name of parameter
- Possible value : DFA
CAT CATEGORIES OF THE COMPANY
- Symbolic name of parameter
- The possible values are the mnemonics :

36 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- ASI,ASO,DS1,DS2,DS3,DS4,DS5,DS6,DS7,DS8,
- RNI,RNR,RNU,RSI,RSO,SR1 à 15.
CAT ALARM CATEGORY
- Symbolic parameter name
- Possible values :
• SI : No action outside working hours
• ID : Non urgent action
• IM : Urgent action
CAT CATEGORIES OF THE COMPANY
- Symbolic name of parameter
- The possible values are the mnemonics :
- SR1 à 15
CATDR Routing according to the calling party category
- Value of parameter STY
CATME ACCESS CODE TO BE SENT ON ATME TEST
- Parameter value
CAUSE NON-COMPLETION CAUSES
- Parameter symbolic name
- Possible values are : 0 < value < 255
CAX CHARGING CATEGORY
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
CAXn CHARGING CATEGORY
- Value of parameter
- 1 ≤ n ≤ 64 (default value : CAX1)
CC CALL CHECK ML GROUP
- Parameter value
CCi CALL CHECK ML i
- Parameter value (1 ≤ i ≤ 8)
CC ML CC
- TYML parameter value
CCAn CHOICE OF ALARM CATEGORY
- Value of TY and DIS parameters
- 1,2,3 or 4 (default value : CALD of FIPAM - CCA03 is forbidden)

3BW 45305 AAAA RKAHA Ed. 07 37 / 236


SYMBOL DICTIONARY

CCDCN CONVERSION TO TECHNICAL RELEASE PN+X OF THE COMMMAND


- Parameter value
This mode allows the OCB reference archives to be converted to Pn+x. Updating of
the OCB archives is followed by initialization of OM function and insertion in the OCB
system.
This option is used after loading the Pn+x software on to the stations.
The option for future initialization is set to NORON.
CCEN EXCHANGE CONTEXT
- Symbolic name of parameter
- Updating of the exchange context
- in working areas. (yes or no)
CCLIB RELEASE COUNTER FOR NON-CHARGED CALLS
- Output symbolic name
- Possible values : 0 à (2³¹ - 1)
CCO CHARGING METERS UNDER OBSERVATION
- Symbolic name of parameter
CCSN CSN COUNTER
- Symbolic name of parameter
- CCSN : <name of counter> - <mark>
CCX CHECKING THE CONNECTIONS
- Value of parameter
CC1 COMMUNICATION CONTROLLER NUMBER 1
- Parameter value
CC2 COMMUNICATION CONTROLLER NUMBER 2
- Parameter value
CC3 COMMUNICATION CONTROLLER NUMBER 3
- Parameter value
CC4 COMMUNICATION CONTROLLER NUMBER 4
- Parameter value
CC5 COMMUNICATION CONTROLLER NUMBER 5
- Parameter value
CC6 COMMUNICATION CONTROLLER NUMBER 6
- Parameter value
CC7 COMMUNICATION CONTROLLER NUMBER 7
- Parameter value
CC8 COMMUNICATION CONTROLLER NUMBER 8
- Parameter value

38 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

CC9 COMMUNICATION CONTROLLER NUMBER 9


- Parameter value
CC10 COMMUNICATION CONTROLLER NUMBER 10
- Parameter value
CC11 COMMUNICATION CONTROLLER NUMBER 11
- Parameter value
CC12 COMMUNICATION CONTROLLER NUMBER 12
- Parameter value
CC13 COMMUNICATION CONTROLLER NUMBER 13
- Parameter value
CC14 COMMUNICATION CONTROLLER NUMBER 14
- Parameter value
CC15 COMMUNICATION CONTROLLER NUMBER 15
- Parameter value
CC16 CALCULATE AND DISPLAY CLIENT DATA
- Value of parameter.
CDC SWITCHING CENTRE
- Symbolic parameter name
- Possible value :
• YES : This means "the CDC site" for an alarm which is customized site by site.
By extension, it also concerns the alarms which are customized as a whole.
CDCOO RETURN TO TECHNICAL RELEASE PN OF OM AND COMMMAND
- Parameter value
This mode allows the OCB system to be returned to technical release Pn. Updating of
the reference archives is followed by initialization of OM function and initialization of
all stations of the OCB starting from the OM (equivalent to INION).
After station initialization has been executed, operation functions are available.
The initialization option for the future is set to NORON.
CDCSO RETURN TO TECHNICAL RELEASE PN OF COMMMAND
- Parameter value
This mode allows the OCB software to be returned to technical release Pn. Updating
of the reference archives is followed by initialization of OM function and initialization
of all stations of the OCB starting from the OM (equivalent to INION).
After station initialization has been executed, operation functions are available.
The initialization option for the future is set to NORON.
CDE STANDBY LOGIC UNIT
- Value of parameter ENS
CDP INDICATOR OF CHANGE OF TECHNICAL RELEASE

3BW 45305 AAAA RKAHA Ed. 07 39 / 236


SYMBOL DICTIONARY

- Symbolic parameter name


Indicator set during a change of technical release in order to enable the specific
"change of technical release" operations.
- Possible values:
- YES : Change of technical release in process
- NO : No change of technical release
CDP REGENERATION OPTION
- Possible value for the REG parameter
CDPC SYSTEM UNDERGOING COMPATIBLE CHANGE OF TECHNICAL RELEASE
- Parameter value
CDPI0 SYSTEM UNDERGOING INCOMPATIBLE CHANGE OF TECHNICAL RELEASE STAGE 0
- Parameter value
- Stage 0 of an incompatible change of technical release corresponds to setting the
stations of subsystem A to Pn+X. During this stage, the traffic is processed by the
stations of subsystem B (Pn).
CDPI1 SYSTEM UNDERGOING INCOMPATIBLE CHANGE OF TECHNICAL RELEASE STAGE 1
- Parameter value
- Stage 1 of an incompatible change of technical release includes shutdown of the sta-
tions of subsystem B (Pn) and the transfer of traffic to the stations of subsystem A
(Pn+x). This stage begins with transfer of OM function .
CDPT REGENERATION WITH COMPLETE DOWNLOAD
- Value of parameter REG
CE CAUSE OF CALL FAILURE
- Symbolic name printed out
CEA EVENT CODE FOR MEASUREMENT WITH CALLING PARTY DIVERSION
- Parameter symbolic name
- The value is assigned in the form <CEAP>-<CEAT>,
- CEAP: event code for continuous measurement between
- 0 and 63
- CEAT: event code for temporary measurement between
- 0 and 255
CEB EVENT CODE FOR MEASUREMENT WITH CALLED PARTY DIVERSION
- Parameter symbolic name
- The value is assigned in the form <CEBP>-<CEBT>,
- CEBP: event code for continuous measurement between
- 0 and 63
- CEBT: event code for temporary measurement between
- 0 and 255

40 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

CEI INPUT CODE ON INITIAL TRANSACTION


- Symbolic name of parameter
CEN EXCHANGE NUMBER
- Symbolic name of parameter
CEN CONCERNED EXCHANGE INDICATED
- Symbolic name of parameter
CF FUNCTION CODE
- Parameter symbolic name
- Possible values
- DEB : Beginning of listing
- FIN : End of listing
CF FUNCTION CODE NUMBER
- Parameter symbolic name
CFAn URGENCY STATUS LEVEL
- CAT parameter value
- 1≤n≤3
CFT CONNECT TO RECORDED ANNOUNCEMENT OR TONE
- DIS parameter value
CHAi DIGITS TO BE SUBSTITUTED TO PREANALYSED DIALLING
- Symbolic name of parameter
- Possible values for i : 1 to 8
- Possible values : 0, 1, ..., 9, A, J, S, C, D
CHA TYPE OF ALARM: HEATING ROOM
- Parameter value
CHA DIGITS TO BE SUBSTITUTED TO PREANALYSED DIALLING
- Symbolic name of parameter
- Number of the digits : 1 to 4
- Possible values for the digits : 0, 1, ..., 9, A, J, S, C, D
CHCK RECALCULATING A FILE’S CHECKSUM
- Symbolic parameter name
- Possible values:
• NO : Do not calculate checksum (default value)
• YES : recalculate checksum
- For a permanent mixed file, the calculation relates to all the un-
changing data (system, country and contracts).
- For other types of file, the calculation relates to the entire file.
CHEA DIGITS TO BE SENT IN ATME TESTS

3BW 45305 AAAA RKAHA Ed. 07 41 / 236


SYMBOL DICTIONARY

- Parameter value
CHECK- PROGRAM CHECKSUM
SUM
- Symbolic name printed out
- Hexadecimal value an 4 characters
CHK PRINTOUT OF GLOBAL CHECK. OF A FILE SERIES OF ITEMS
- Value of parameter.
CHKA PRINTOUT OF CHECKSUM OF EACH ITEM OF A FILE SERIES
- Value of parameter.
CHKC CURRENT CHECKSUM OF A FILE
- Symbolic output name
- For a permanent file, the current checksum reflects the unchanging data on a site
(system data plus country plus contracts)
- For semi-permanent or temporary files, the current checksum has no great signifi-
cance.
CHKD CURRENT DISK CHECKSUM OF A FILE
- Symbolic output name
- Current checksum (CHKC) read on disk.
CHKK RECALCULATED CHECKSUM
- Symbolic output name
- In the absence of specific instructions (parameter MSK), the recalculated checksum of
a permanent file is identical to its current checksum (CHKK=CHKC).
CHKM COMPUTATION OF PROGRAM CHECKSUM
- Symbolic name of parameter
CHKM CURRENT MEMORY CHECKSUM OF A FILE
- Symbolic output name
- Current checksum (CHKC) read in memory.
CHKO ORIGINAL CHECKSUM
- Symbolic output name
- Manufacturer’s checksum, before patching.
CHKS CHECKSUM
- symbolic output name
CHN FIGURES DIALLED BY SUBSCRIBER
- Symbolic name printed out
CHO TIME METERS UNDER OBSERVATION
- Symbolic name printed out
CHP DIGITS OF PREANALYSIS PREFIX FOR THE CSN
- Symbolic name of parameter

42 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Number of digits : 1 to 4
- Possible values for the digits : 0, 1, ..., 9, A, J, S, C, D
CHSE INTERROGATED FIELD
- Symbolic name of parameter.
CHSF FILTERING OF RECORDS USING VALUE OF A FIELD
- Symbolic parameter name
- In the form <field>-<value>
• A <field>-<value> pair defines a criterion.
• Items meeting the criterion "field=value" are returned.
• A list indicates that all criteria must be true for the item to be retained.
• The field-name "table" with no index is a short way of listing all the items in the
table.
CHSI NAME OF STRUCTURE FIELD
- Symbolic name of parameter.
CIA CHARGING CATEGORY (depending of geographic zone)
- Symbolic name printed out
- Value from 1 to 255
CIA1 CHARGING CATEGORY (depending of geographic zone)
- Symbolic name printed out
- Value from 1 to 128
CIA2 CHARGING CATEGORY (depending of geographic zone)
- Symbolic name printed out
- Value from 1 to 128
CIB INSUFFICIENT BATTERY DISCHARGE CAPACITY
- Symbolic name output or symbolic name of parameter
- Digital subscriber
CIC CIRCUIT IDENTIFICATION CODE
- Symbolic name of parameter
- Value from 1 to 4095
CII ALLOCATION CODE TO BE IGNORED
- DIS parameter value, (analysis)
CIX CHARGING CATEGORY
- Symbolic name printed out
- Value from 1 to 255
CIX1 CHARGING CATEGORY
- Symbolic name printed out
CL CLEAR

3BW 45305 AAAA RKAHA Ed. 07 43 / 236


SYMBOL DICTIONARY

- Value of parameter REQ


CLABn CLASS OF SUBSCRIPTION
- Value of parameter CAT
- Refer to operating data
CLAD CLASS OF CONTROL STATION DUMP
- Symbolic parameter name
The class DUMP defines the data dumped by the system.
- Possible values:
0 : Minidump limited in volume (standard value)
- 1 : Dump of "faulty" agent private memory
- 2 : Minidump unlimited in volume
- 3 : Dump of predefined zones
- 4 : Dump of "faulty" agent private memory and of common memory
- 5 : Dump of predefined files
- 6 : Dump of "faulty" agent and common memory temporary files
- 7 : Manual dump
CLC CLASS OF COMMANDS
- Value of paramater
CLC MANIPULATED DATA: COMMAND CLASSES
- Value of parameter
- No allowable value
CLEAR STATISTICS COUNTERS RESET OPTION
- Symbolic name of parameter
CLI AIR CONDITIONING ALARM
- Symbolic name printed out
CLI Routing depends on calling subscriber identity
- STY parameter value
CLI TYPE OF ALARM: AIR CONDITIONING
- Parameter value
CLICH CODE INDICATING THE FAULT LEVEL
- Symbolic name of parameter
- Possible values :
• if 1 ≤ CLICH ≤ 2, only anomaly item will be selected
• if 3 ≤ CLICH ≤ 5, only alarms item will be selected
CLR REDUCTION CLASS
- Parameter symbolic name

44 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Five possible values between 0 and 31


CLRAE AUTOMATIC CONGESTION REDUCTION CLASS
- Parameter symbolic name
- The value is assigned in the form : A-B
- A : Reduction class for congestion level 1
- B : Reduction class for congestion level 2
- A and B are between 0 and 31
CLRES UP CONGESTION REDUCTION CLASS
- Parameter symbolic name
- The value is assigned in the form : A-B-C
- A : Reduction class for congestion level 1
- B : Reduction class for congestion level 2
- C : Reduction class for congestion level 3
- A, B and C are between 0 and 31
CLTH COUPLER CLTH
- Value of parameter SFCA
CM UNITS AVERAGE LOAD (MESHES - INPUT SECTION)
- Symbolic name printed out
CMA GLOBAL AVERAGE LOAD OF EXCHANGE
- Symbolic name printed out
CMD COMMAND NAME
- Symbolic name of parameter
- Possible values : : from 1 to 6 characters.
CMD COMMAND NAME
- Symbolic name of parameter
- Possible values : : from 1 to 6 characters.
CMISN OM INITIALIZATION WITH CONVERSION TO TECHINCAL RELEASE PN+X OF THE
MULTIPLEX COUPLER
- Parameter value
This mode alows the initialization to the Pn+x technical release of both OM function
and inter-station multiplex coupler, together with insertion into the OCB system.
This option is used after the conversion to the Pn+x technical release of the mainte-
nance station in ALONE mode.
All operation functions are available.
The option for future initialization is set to ALONE.
CMP SPEAKING MACHINES COUPLER
- Symbolic name printed out

3BW 45305 AAAA RKAHA Ed. 07 45 / 236


SYMBOL DICTIONARY

CMP PRINCIPAL COUPLER


- Value of parameter SFCA
CMPH PRINCIPAL AND CLTH COUPLER
- Value of parameter
CMS SECONDARY COUPLER
- Value of parameter SFCA
Cn COMPLETE CHANGE OF FIGURES
- Value of parameter DIS
CN CALCULATE CLIENT DATA AND NO DISPLAY
- Value of parameter.
CNEA REMOTE DIGITAL CONCENTRATOR FOR ANALOGIC SUBSCRIBER
- Value of parameter
CNEB REMOTE DIGITAL CONCENTRATOR BROAD BAND
- Value of parameter
CNEH REMOTE DIGITAL CONCENTRATOR HIGH DENSITY
- Value of parameter
CNEM REMOTE DIGITAL CONCENTRATOR FOR ANALOGIC/DIGITAL SUBSCRIBER
- Value of parameter
CNEP MAIN REMOTE DIGITAL CONCENTRATOR
- Value of parameter
CNES AUXILIARY REMOTE DIGITAL CONCENTRATOR
- Value of parameter
CNFLB SMB SOFTWARE SETUP
- Parameter symbolic name
- possible values: see document entitled "System data dictionary"
- CNFLB defines the software setup of a SMB
CNLA LOCAL DIGITAL CONCENTRATOR FOR ANALOGIC SUBSCRIBER
- Value of parameter
CNLB LOCAL DIGITAL CONCENTRATOR BROAD BAND
- Value of parameter
CNLH LOCAL DIGITAL CONCENTRATOR HIGH DENSITY
- Value of parameter
CNLM LOCAL DIGITAL MIXED CONCENTRATOR
- Value of parameter
CNPB MAIN REMOTE DIGITAL CONCENTRATOR BROAD BAND
- Value of parameter

46 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

CNPH MAIN REMOTE DIGITAL CONCENTRATOR HIGH DENSITY


- Value of parameter
CNSB AUXILIARY REMOTE DIGITAL CONCENTRATOR BROAD BAND
- Value of parameter
CNSH AUXILIARY REMOTE DIGITAL CONCENTRATOR HIGH DENSITY
- Value of parameter
CNX CAPACITY FOR BEARER SERVICE
- Value of the CTA parameter
COB CIRCUIT MEASURED IN GROUP
- MAR parameter value
COC SIGNALLING LINK
- Symbolic name of parameter
- Possible value : from 0 to 15
COCA CARRIER NUMBER
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 to 2 bytes
COD BARRED ACCESS IDENTIFICATION CODE
- Symbolic name of parameter
- 4-digit number
COD RECORD CODE OR RECORD ITEM TO SELECT
- Symbolic name of parameter
CODE ALLOCATION CODE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 to 3 bytes
CODE INTERPRETATION TYPE
- Symbolic parameter name.
- ASCII or EBCDIC interpretation.
CODE TYPE OF INTERPRETATION
- Symbolic name of Parameter.
- Possible values :
- AA ASCII interpretation
- E EBCDIC interpretation

3BW 45305 AAAA RKAHA Ed. 07 47 / 236


SYMBOL DICTIONARY

CODE GFU IDENTITY CODE


- Symbolic name of parameter
- Possible values : 1 to 36535
CODE CODE NUMBER TO BE OBSERVED
- Symbolic name of parameter
- Value : 1 to 15
COF CONFERENCE CALL RIGHT
- Value of parameter
COLP RIGHT FOR THE CALLING PARTY TO HAVE THE CALLED PARTY IDENTITY
- Value of the CAT parameter
COLR RIGHT TO THE NON-DIVULGATION OF ONE’S IDENTITY TO THE CALLING PARTY
- Value of the CAT parameter
COM SWITCHING ALARM
- Symbolic name printed out
COMi HANDLING SWITCH i ML GROUP
- Parameter value (1 ≤le i ≤le 8)
COM TYPE OF ALARM: SWITCHING
- Parameter value
COMAi HANDLING SWITCH i BRANCH A ML
- Parameter value (1 ≤le i ≤le 8)
COMBi HANDLING SWITCH i BRANCH B ML
- Parameter value (1 ≤le i ≤le 8)
COND SERVICE PROVIDED WITH RESTRICTION
- Parameter value
CONF ALARM MULTIPLEX CONFIGURATION OUTPUT
- Symbolic name of parameter
- No associated value
- Lists the actual configuration of the alarm multiplex.
CONF PARAMETER OF CONFIDENTIALITY
- Symbolic name of parameter
- Possible values : YES or NO ( Implicit value YES).
CONFA CONFIGURATION OF INFRASTRUCTURE ALARMS
- Symbolic name of parameter
- Number defined in the document "Nucleus data dictionary"
- Defines the configuration of the infrastructure alarms (description of CSALs and of
associated alarms).
CONFL SOFTWARE CONFIGURATION OF STATION

48 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic parameter name


- Number listed in the document "system data dictionary"
- Describes a station’s software configuration
CONFM HARDWARE CONFIGURATION OF STATION
- Symbolic parameter name
- Number listed in the document "system data dictionary"
- Describes a station’s hardware configuration
CONFR CONFIGURATION OF SWITCHING NETWORK
- Symbolic parameter name
- In the form <t>-<b>-<c>
- <t> Type ( 0 for MCX or 1 for RCH )
- <b> Row ( 0 for branch A or 1 for branch B )
- <c> Configuration ( 0 ≤le c ≤le 255 )
CONT VALUE OF OBSERVED METER
- Symbolic name printed out
COP BARRED ACCES IDENTIFICATION CODE
- Symbolic name of parameter
- Number of 4 digits.
COPY COPY OF AN ARCHIVE FILE
- Parameter value
- Used to transfer the contents and characteristics (FIAF, FCDF) of a file. If the file is
handled by FOCE, the space reserved in FOCE for the file is transferred.
COPY COPY
- Parameter value.
CORR ERROR CORRECTION METHOD
- Symbolic name of parameter
- Possible values :
• BASE (by default)
• RCP
CO2G ML COM 2G
- TYML parameter value
CP PRIORITY CATEGORY OF A CIRCUIT GROUP
- Symbolic name of parameter
- Possible values : 0, 1
CP CP IDENTIFICATION NUMBER
- Symbolic name of parameter
- Possible values : 0 to 127

3BW 45305 AAAA RKAHA Ed. 07 49 / 236


SYMBOL DICTIONARY

CPOR SOURCE COUPLER


- Symbolic name printed out
CPT NUNBER OF FAULTS
- Symbolic name printed out
CPTX EXISTENCE OF CALL REPORT
- Value of parameter CTA (Circuit Goup management) or DIS (Routing management).
CRC CRC4 ACTIVATION STATUS
- Symbolic name of parameter
- Possible values are ACT and NACT
CRIn NON-DEDICATED DISCRIMINATIONS FOR IN-CS1 SERVICES
- Value of parameter CAT
- 1 ≤ n ≤ 32 (NON EXCLUSIVE)
CRO OBSERVED RESULT METERS
- Symbolic name of parameter
CR1 IDENTIFICATION OF EQUIPMENT SPECIFIED IN COMMAND
- Symbolic name printed out
CR2 IDENTIFICATION OF FIRST CONNECTED EQUIPMENT
- Symbolic name printed out
CR3 IDENTIFICATION OF SECOND CONNECTED EQUIPMENT
- Symbolic name printed out
CS SATELLITE CENTER
- Symbolic name of parameter
- Number of the satellite center of an URAD
CSC CONTINUITY ROUTINE TEST
- Symbolic name of parameter
- Possible values :
• 0 : 2-wire circuit without continuity test
• 1 : 4-wire circuit without continuity test
• 2 : 2-wire circuit with continuity test
• 3 : 4-wire circuit with continuity test
CSE ELECTRONIC SUBSCRIBER CONNECTION UNIT
- Value of parameter
CSED REMOTE SUBSCRIBER CONNECTION UNIT
- Symbolic name printed out
CSEL LOCAL SUBSCRIBER CONNECTION UNIT
- Symbolic name printed out

50 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

CSN SUBSCRIBER DIGITAL ACCESS UNIT


- Symbolic name printed out
CSN SUBSCRIBER DIGITAL ACCESS UNIT
- Value of parameter
CSP LOGIC NUMBER OF CNSP INSIDE MTT
- Symbolic name of parameter
- Value : between 0 and 23
CSPHS THRESHOLD OF NUMBER OF CNSPE’S OOS
- Symbolic name of parameter
- Percentage-value assigned
CSS7 COUPLER Nº7
- Value of parameter SFCA
CTn CHARGING AND ROUTING CATEGORY
- Value of parameter
- Possible value :1 ≤ n ≤ 32
- (Implicit value : CT1)
CT CATEGORY OF DEMANDER
- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value numeric on 1 byte
CTA DISCRIMINATIONS (CIRCUIT GROUP)
- Symbolic name of parameter
- Possible values :(EXPORT/TRANSIT)
- TR, RTT, ATn, ZGn, TKO, AUB, PX, FDn, CACn, CAXn, ZTXn, VSGn, SRn,
- CP, DTC, DF1, DF2, DFAn, DFBn, DFCn, DFDn, DFEn, DFFn, DFGn, DFHn,
- SOCn, DCA, IDT, TIDn, DSE, SAT, DAI, FMP, IDI, RTS, AEGR, FRIn, PLMN,
- BL31, CNXn, BSM, TOS, PROFn, RAn.
- ATn - 1 ≤ n ≤ 32
- ZGn - 1 ≤ n ≤ 64
- FDn - 1 ≤ n ≤ 7
- CACn - 1 ≤ n ≤ 64
- CAXn - 1 ≤ n ≤ 64
- ZTXn - 1 ≤ n ≤ 128
- VSGn - 1 ≤ n ≤ 15
- SRn - 1 ≤ n ≤ 15
- DFAn - 1 ≤ n ≤ 15

3BW 45305 AAAA RKAHA Ed. 07 51 / 236


SYMBOL DICTIONARY

- DFBn - 1 ≤ n ≤ 15
- DFCn - 1 ≤ n ≤ 15
- DFDn - 1 ≤ n ≤ 15
- DFEn - 1 ≤ n ≤ 15
- DFFn - 1 ≤ n ≤ 15
- DFGn - 1 ≤ n ≤ 15
- DFHn - 1 ≤ n ≤ 15
- PROFn- 1 ≤ n ≤ 15
- RAn - 1 ≤ n ≤ 15
- SOCn - 1 ≤ n ≤ 2047
- TIDn - 1 ≤ n ≤ 3
- FRIn - 1 ≤ n ≤ 32
- CNXn - 1 ≤ n ≤ 15
- Possible values :(TRANSIT)
- AECH,CRA.
CTI OPERATION AND MAINTENANCE CENTRE
- Value of parameter
CTO ADDING METERS UNDER OBSERVATION
- Symbolic name of parameter
CTR CAN BE CUSTOMIZED AS A WHOLE BY THE MANUFACTURER
- Parameter value
CTRL Y/N CHECK ON VOLUME VALID. BEFORE MAGT. PREMARKING
- Symbolic name of parameter
- CTRL = O (yes)
- Remarking is carried out only if the
- validity date of the first file is
- out dated.
- In this case if the oconer’s (ident) name
- is not indicated in the command, the old
- ident is conserved.
- CTRL = N (no)
- The magtape is premarked without any check
- on the validity of the replaced data.
CTRL MONITORING FUNCTION
- Value of parameter
CTRL CHECK FUNCTION

52 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Name of parameter
- possible values : YES , NO
CTRL PRELIMINARY CHECKS
- Parameter value
- Used before a change of release or software, the preliminary checks make it possible
to monitor:
• The breakdown of the system into two subsystems
• If necessary. the assignment of the stations to the subsystems is modified.
• The status of all the stations.
• The number of alarms present.
• The number of units of itemized billing not acknowledged.
• The date of saving of charging accounts.
- The preliminary checks must be carried out on the system at Pn release.
CTRL CHECK THE CATALOGUE
- Parameter value
- Used to check that FIAF files in the memory are identical to FIAF files on the disk.
CTSM SIGNALLING TRANSFER CAPACITY
- Parameter code
- Value expressed as number of messages per second (max 2048).
CTX CHARGE CODE NUMBER
- Symbolic name of parameter
- Values depending on MDTX
- from 0 to 61 and 64 to 255
CTXS NEXT CHARGE CODE NUMBER
- Symbolic name of parameter
- Possible values : 0 to 255
CUR DIALLING CODE FOR EMERGENCY SERVICE
- Symbolic name of parameter
- Number of digits : 1 to 10
- Possible values for the digits : 0, 1, ..., 9, A, J, S, C, D
CUTC UTC COUNTER
- Symbolic name of parameter
- CUTC = <name of counter> - <mark>
CVn VISUAL DISPLAY UNIT
- Value of parameter
CXP PERMANENT CONNECTION
- Symbolic name printed out

3BW 45305 AAAA RKAHA Ed. 07 53 / 236


SYMBOL DICTIONARY

- CXP = VD : data channels


- CXP = VG : management channels
CYC MEASUREMENT CYCLE TO BE CARRIED OUT ON A CIRCUIT (ROUTINE TEST)
- Symbolic parameter name
- Possible values:
• CYC=0 : pulse and attenuation measurements,
• CYC=1 : noise measurement (if PSOPHOMETER present and noise measure-
ment authorized),
• CYC=2 : noise, pulse and attenuation measurement.
CYMES MEASUREMENTS CYCLE
- Symbolic name printed out
CYMON SCHEDULER CYCLE
- Symbolic name printed out
CYSML SERVICE RELATIVE CYCLE TIME
- Symbolic name printed out.
CYSPM SUPERVISOR RELATIVE CYCLE TIME
- Symbolic name printed out
CYSPU SUPERVISOR REAL CYCLE TIME
- Symbolic name printed out
CYSUC SERVICE REAL CYCLE TIME
- Symbolic name printed out.
D FRAME SERVICE
- Parameter value
D SIGNALLING LINK TRANSMISSION RATE
- Symbolic name of parameter
- Possible values :
• N for 64 kbits/second (by default)
• A for 4.8k bits/second.
D O/G TRAFFIC
- Parameter value
Di TYPE D
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15
DAAn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CAT
DABn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CAT

54 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DAC ENTITLED TO HOLD FOR ENQUIRY FACILITY


- Value of parameter CAT
DACi V5.x ACCESS DEFAULT OF LEVEL i
- Value of parameter ETAT
DADn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CAT
DAI INTERNATIONAL SERVICE INPUT OR OUTPUT
- Value of parameter CTA
DAL ANNOUNCEMENT INDICATING START OF ALARM
- Symbolic name printed out
DAMX FLOW RING
- Symbolic parameter name
- In the form <a>-<d>
- <a> Hardware address of the ring
- <d> Flow : 4 or 16 ( expressed in Mbit/s for each ring )
DANU WAIT PERIOD DURATION AFTER DIALLING
- Symbolic name output
DASV DATA TO BE SAVED
- Symbolic parameter name
- Possible values :
• BURM save "MOAB" data
Used to save the data that can be modified by the subscriber from the exchange
archive files (except files FIAF and FCDF). If the file is handled by FOCE, the
space reserved in FOCE for the file is transferred.
• BUR save exchange data
Used to save the semi-permanent data from the exchange archive files (except
files FIAF and FCDF). If the file is handled by FOCE, the space reserved in FOCE
for the file is transferred.
• TAX save charge meter
Used to save the charge meter values of files FITAX and FICLX in the XATX
archive.
• TAXC save and test charge meter
Used to save, and to test consistency between the two ML TXs, the charge meter
values of files FITAX and FICLX in the XATX archive.
• FDAT save non-catalogue data
Used to save all files except FIAF and FCDF from the exchange archive.
• CTRL check catalogues in memory
Used to check that FIAF files in the memory are identical to FIAF files on the disk.

3BW 45305 AAAA RKAHA Ed. 07 55 / 236


SYMBOL DICTIONARY

DAT DATE AT WHICH THE OMC CLOK IS TO BE INITIALIZED


- Symbolic name of parameter
- On the form <year>-<month>-<day>
DAT DATE AT WHICH THE OMC CLOK IS TO BE INITIALIZED
- Symbolic name of parameter
- On the form <year>-<month>-<day>
• Year included between 00 and 99
• Month included between 01 and 12
• Day included between 01 and 31
DAT DATE OF EXECUTION OF A COMMAND
- Symbolic name of parameter
- On the form YEAR/MONTH/DAY
DAT DATE OF EXECUTION OF A COMMAND
- Symbolic name of parameter
- On the form YEAR-MONTH-DAY
DATi DATES OR DATE LIMITS
- Symbolic name of parameter
- On the form 1 ≤ i ≤ 2
- DAT 1 : must be found in current month (N.)
- DAT 2 : must be found in next month (N+1)
DAT DATE OF PHYSICAL FILE GENERATION
- Symbolic name of parameter
- On the form YEAR-MONTH-DAY
DATA LIST DATA ZONE OF ABORTED COMPONENT.
- Parameter value
- Parameters "DEB" and "NSEC" can be specified.
DATE ITEM OUTPUT DATE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• year-month-day/hour-minute-second
DATE DATE AND TIME OF SUPERVISION START
- Symbolic name printed out
DATLA DATE OF CREATION OF GTLA TAPE
- Symbolic name of parameter
- In the form <year>-<month>-<day>

56 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DATLC DATE OF CREATION OF GTLC TAPE


- Symbolic name of parameter
- In the form <year>-<month>-<day>
DATVL DATE OF VALIDITY
- Symbolic name of parameter
- On the form YEAR-MONTH-DAY
DAT1 DATES OR DATE LIMITS
- Symbolic name of parameter
- On the form : YY-MM-DD
- The value must be found in current month n
DAT2 DATES OR DATE LIMITS
- Symbolic name of parameter
- In the form : YY-MM-DD
- The value must be found in next month
DAY INDICATE THE DAY DATE IN THE YEAR
- Symbolic name printed out
- The value given to the parameter must be
- included between 1 and 366.
DAY INDICATE THE DAY DATE IN THE YEAR
- Symbolic name printed out
- The value given to the parameter must be included between 1 and 366.
DA1 STANDARDIZED SUBS.DISCRIMINATION
- Value of parameter CAT
DA2 STANDARDIZED SUBS.DISCRIMINATION
- Value of parameter CAT
DBG DEBUG OPTION
- Symbolic name of parameter
DC DISK
- Value of parameter
DCA INCOMING CALL CHARGE
- Value of parameter CTA
DCBn STANDARDIZED CIRCUIT DISCRIMINATION
- Parameter value
- Test of the controlled NT1 battery discharge (digital subscriber test)
DCE INCOMING CALL DETAIL
- LISTE parameter value

3BW 45305 AAAA RKAHA Ed. 07 57 / 236


SYMBOL DICTIONARY

DCIn ENTITLEMENT TO ALLOCATION CODE OF n DIGITS AFTER DIALLING


- Value of parameter CAT
- 1 ≤ i ≤ 5 (DCI1 implicit value)
DCM DEVICE MULTIPLIER OF CIRCUITS
- Value of the CTA parameter
DCO CALL DURATION
- Symbolic name printed out
- Value indicated in seconds
DCO EFFECTIVE DURATION IN SECONDS
- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value numeric on 2 bytes
DCS OUTGOING CALL DETAIL
- LISTE parameter value
DD DATE OF BEGINNING OF RATE TIMEBAND
- Symbolic parameter name
- In the form <year>-<month>-<day>
DEA DETAILED INFORMATION ON INCOMING CALLS
- Value of parameter
DEB BEGINNING OF LISTING
- Parameter value
DEB BEGINNING of SECTOR
- Symbolic name of Parameter.
- Hexadecimal number.
- By default DEB=0, first sector of the identifier.
DEB BEGINNING SECTOR
- Symbolic parameter name.
- Specifies the shift, expressed in sectors, in relation to the beginning of the zone to be
listed.
- Default value, DEB=0: list from the beginning of the requested zone.
DEDE CALLED PARTY DESIGNATION NUMBER
- Symbolic name on output
- Output during reading of TLV france format itemized billing type magnetic tape
- Possible values:
• from 1 to 32 digits preceded by the nature of the dialling
DEFLI Ethernet links defense
- Parameter symbolic name

58 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values: YES or NO


- If DEFLI = YES, the ethernet links defense of the specified coupler is activated, other-
wise, if DEFLI = NO, the defense is inhibited. By default DEFLI = NO.
DEI ROUTING WITH INTERNATIONAL ACCOUNTING
- DIS parameter value
DEL DELAY FOR RE-ACTIVATION
- Symbolic name of parameter
- Possible value : YES (by default) or NO
DENI MALFUNCTION NOT IDENTIFIED
- symbolic output name or parameter value
- status value for a digital subscriber access
DEP DISPLACEMENT IN BYTES RELATIVE TO BEGINNING OF FILE
- Symbolic parameter name
- Value from 0 to 32767
- Calculation of the address of the record to be consulted or modified:
- NUM=i, DEP=d
- The record of length l is therefore at (i*l) + d bytes from the beginning of the file.
DER IDENTITY OF LAST TESTED CIRCUIT
- Symbolic name printed out
DERAN MALFUNCTION
- Value of parameter STTUS
DEST DESTINATION
- Symbolic name of Parameter.
- Possible values :
- The files CTILAS, CTIPRM, TRVLAS, TRVPRM, CTIFIL.
- The associated logic disks DLCONF and DLFICH.
DET DURATION OF CALL SETUP
- Symbolic name printed out
- Value indicated in seconds
DEV DEVICE ACCESS TO A FILE
- Value of parameter
- The user calculates the addressing
DFn LINE SHIFTED ON RECORDED ANNOUNCEMENT
- Value of parameter CAT
- Possible value : 1 ≤ n ≤ 31
DF DATE OF END OF RATE TIMEBAND
- Symbolic parameter name

3BW 45305 AAAA RKAHA Ed. 07 59 / 236


SYMBOL DICTIONARY

- In the form <year>-<month>-<day>


DFAn NON - DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA
DFA DROIT AU FILTRAGE DES APPELS ENTRANTS
- Value of parameter CAT
DFAU SIGNAL ERROR ON CIRCUIT
- Value of parameter
- O/G circuit (to sent signal missing)
- I/C circuit (Release signal missing)
DFBn NON - DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA
DFCn NON - DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA
DFDn NON-DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA
DFEn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CTA
- 1 ≤ n ≤ 15
DFFn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CTA
- 1 ≤ n ≤ 15
DFGn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CTA
- 1 ≤ n ≤ 15
DFHn NON-DEDICATED DISCRIMINATIONS
- Value of parameter CTA
- 1 ≤ n ≤ 15
DFLj ANNOUNCEMENT DURATION
- PARAM parameter value
- j is between 1 and 255
DFU ENTITLEMENT TO USER-TO-USER FACILITY
- Value of parameter CAT
DF1 NON - DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA
DF2 NON - DEDICATED LINK SET DISCRIMINATIONS
- Value of parameter CTA

60 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DG NAME OF LOCAVAR DIAG. INDICATED BY REPAIR COMMAND


- Symbolic name of parameter
DGCAF DEGREE OF EMERGENCY SITUATION
- Symbolic name of parameter
DH1 Listing start date
- Symbolic name of parameter.
- In the form <year>-<month>-<day>-<hour>
DH1 Listing end date
- Symbolic name of parameter.
- In the form <year>-<month>-<day>-<hour>
DIAG LOCALIZATION DIAGNOTIC
- Symbolic name in a printout line
- DIAG = <typ> <1> <n1> p <n2>
- <typ> : symbol of the type of rack letter
- <1> : corresponding to the executable module
- which has produced the diagnostic
- <n1>,<n2> : decimal integers as mark index of
- the diagnostic in the executable module
DIAG ADAPTER FAILURE
- Parameter value
- The adapter has failed. It is no longer processing traffic.
DIFA BROADCAST OF THE DATA IN THE STATIONS OF SUBSYSTEM A
- Parameter value
- Used at an incompatible release change, the broadcasting of data in the stations of
subsystem A comprises:
• The halting of the stations of subsystem A.
• By setting in INDL then BLOM.
• The switch to CDPI1 system status.
• The initialization of the stations of subsystem A.
• The stations are loaded with the Pn+x data from the working zone.
DIFB BROADCAST OF DATA IN THE STATIONS OF SUBSYSTEM B
- Parameter value
- Used at an incompatible release change, this phase is used to initialize the stations of
subsystem B.
- The stations of subsystem B have been set in BLOM during the switchover of the CDC
to Pn+x.
- The stations are loaded with the Pn+x data from a duplicate station.

3BW 45305 AAAA RKAHA Ed. 07 61 / 236


SYMBOL DICTIONARY

- The broadcast of data in subsystem B must be carried out after switchover to Pn+x.
DIFC BROADCAST OF DATA IN THE STATIONS
- Parameter value
- Used at a compatible release change, the broadcasting of data in the stations com-
prises:
• Switching to CDPC system status.
• The halting of the stations of subsystem A.
• By setting in INDL and then BLOM.
• The initialization of the stations of subsystem A.
• The stations are loaded with Pn+x data from the working zone.
• The halting of the stations of subsystem B (except support SMA of ML PUPE).
• By setting in INDL and then BLOM.
• The initialization of the stations of subsystem B (except support SMA of ML PUPE).
• The stations are loaded with the Pn+x data from a duplicate station of subsystem
A.
• The halting of the ML PUPE support SMAs of subsystem B
• By setting in INDL and then BLOM.
• The initialization of the ML PUPE support SMAs of subsystem B.
• The stations are loaded with the Pn+x data from a duplicate station of subsystem
A.
• Switchover of system to operational status(ES)
- Broadcasting in the ML PUPE support SMAs is performed station by station.
DIFF DEFERRED
- Value of parameter.
DIFNn DIGITAL MULTI-TRANSMISSION OPTION FOR LD CREATION
- Value of parameter DISLD
- Possible values :
• n = 0 : analog multi-transmission,
• n = 1 : digital multi-transmission.
DINS ADAPTER NOT INSERTED / ADAPTER TO BE REMOVED
- parameter value
- parameter of the AMXMO command :
• removal of an adapter
- parameter of the AMXIL command :
• output of the adapters removed (as seen from the MAC protocol). This situation
is normal for the secondary couplers of a non-operational SM.
DIPA RIGHT TO IDENTIFY THE CALLING PARTY DURING THE CALL PHASE
- Value of the CAT parameter

62 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DIRi ECHO CANCELLER ORIENTATION


- Value of the parameter AECHO
- Possible values:
- i=1 orientation towards the PCM (default value)
- i=2 orientation towards the network
DIR DIRECT ACCESS TO A FILE ITEM
- Value of parameter
- The item is accessed through its number
DIR TAXIL ON TAPE
- value of parameter OPT
DIS SWITCHING TO REMOTE MODE
- Value of parameter
- The remote mode must be enabled to open the session.
DIS CLASS OF SERVICE (DIVERSION)
- Parameter symbolic name
- Possible values:
- INX Initial selection digits
- MTX Charge modification
- NIN Initial selection digits to be forwarded
- FNT Format of number to be sent
- CFT Connect to recorded announcement or tone
- NRP No charge with backward transmission of answer signal
- MOB Selected call completion code
- DV1 - Class of service
- to DV8
DIS DISCRIMINATIONS (preanalysis)
- Symbolic name of parameter
- Possible values :
- DP1 Non-dedicated preanalysis discrimination 1
- DP2 Non-dedicated preanalysis discrimination 2
- DP3 Non-dedicated preanalysis discrimination 3
- DP4 Non-dedicated preanalysis discrimination 4
- DP5 Non-dedicated preanalysis discrimination 5
- DP6 Non-dedicated preanalysis discrimination 6
- DP7 Non-dedicated preanalysis discrimination 7
- APU Call presumed to be urgent

3BW 45305 AAAA RKAHA Ed. 07 63 / 236


SYMBOL DICTIONARY

- SYK Syntax facility for keyboard


- PID Prefix for IDT
- INZ Insertion of zone code
- PSI Prefix for identification secrecy on call-per-call basis
- MTI Indicator for international transit
DIS DISCRIMINATIONS (Analysis)
- Symbolic name of parameter
- Possible values :
- DI1 Non-dedicated analysis discrimination 1
- DI2 Non-dedicated analysis discrimination 2
- DI3 Non-dedicated analysis discrimination 3
- DI4 Non-dedicated analysis discrimination 4
- DI5 Non-dedicated analysis discrimination 5
- DI6 Non-dedicated analysis discrimination 6
- DI7 Non-dedicated analysis discrimination 7
- DI8 Non-dedicated analysis discrimination 8
- DRIn Service trigger routing code (n from 1 to 32)
- CII allocation code to be ignored
- IROC inhibition of automatic call-back on busy called party in incoming
- IID area code with IDT option on a per call basis
- IMPO operated imported routing code
DIS CLASS OF SERVICE (Routing)
- Symbolic name of parameter
- The possible values are the following symbols :
- DR2, DR3, DR4, DR5, DEA, DRAi, A, AB, PRi, CN, IMi, AMi, NTi,
- IRX, ACS, DEI, RFI, FINU, IECT, IECX, REAi, FITX, IPROC, RAi
- SRi : 1 ≤ i ≤ 15
- RVi : 1 ≤ i ≤ 63
- TSCi : 1 ≤ i ≤ 15
- DRAi : 1 ≤ i ≤ 15
- PRi : 1 ≤ i ≤ 15
- IMi : 1 ≤ i ≤ 15
- AMi : 0 ≤ i ≤ 10
- NTi : 1 ≤ i ≤ 8
- RAi : 1 ≤ i ≤ 15
- REAi : 1 ≤ i ≤ 2

64 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DIS CLASS OF SERVICE (MIC)


- Symbolic name of parameter
- Possibles values:
- CCAi
DISC DISCRIMINATIONS ASSOCIATED TO A UNIT FILE
- Symbolic name of parameter
- Number in hexadecimal form
- From H’00’ to H’FF’ with DISC0 = H’01’, DISC7= H’80’
DISC ETU DISCRIMINATION
- Symbolic parameter name
- Values comprised between 0 and 2.
- 0: Non reconfigurable ETU
- 1: Reconfigurable ETU
- 2: Back-up ETU
DISLD DISCRIMINATIONS OF A DATA LINK
- Symbolic name of parameter
- Possible values : RCONFn, SURVn, FSLDn, FILM, TYFIL
DISLD DISCRIMINATIONS OF A DATA LINK
- Symbolic name of parameter
- Possible values : RCONFn, SURVn, FSLDn, FILM, TYFIL
DISLR MATRIX LINK DISTRIBUTION BASED ON TYPE.
- Parameter symbolic name
- In the form <matrix link type>-<number of matrix links for this type>
- Possible type of matrix link:
- - N7 : N7 matrix link
- - RGF : frequency receiver and generator matrix link
- - CCF : conference circuit matrix link
- - V52 : V5.2 matrix link
- - V52P : packet mode V5.2 matrix link
- - GT : tone generator matrix link
- - V23 : V23 matrix link
DITA MALFUNCTION OF AN ITA
- Output symbolic name
- Parameter value for digital subscriber
DIU ENTITLEMENT TO USER-TO USER INFORMATION
- Value of parameter CAT

3BW 45305 AAAA RKAHA Ed. 07 65 / 236


SYMBOL DICTIONARY

DIU2 ENTITLEMENT TO TYPE 2 USER INFORMATION


- Value of parameter CAT
DIV TYPE OF ALARM: MISCELLANEOUS
- Parameter value
DIV MISCELLANEOUS
- Value of parameter
DIXM value of parameter SD
- DIXMn with n = 5,6,7,8 or 9
DI1 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI2 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI3 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI4 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI5 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI6 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI7 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DI8 STANDARDIZED ANALYSIS DISCRIMINATION
- Value of parameter DIS
DL LOGICAL DISK
- Symbolic parameter name
DL is used to designate a logical disk belonging to an OM secondary memory. The
logical disk identifier comprises a space name and a logical disk number within the
space. The space is a subset of the MSO.
- Possible values:
- CTIFIL-1, CTIPRM-2, ...
DLAN LINE FAULT
- Symbolic name printed out or value of parameter
- Digital subscriber
DLAR RR FAULT OR CPA-RR SECTION FAULT FOR LINES EQUIPPED WITH REPEATERS
- symbolic output name or parameter value
- status value for a digital subscriber access

66 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DLAT TNR FAULT OR TNR-RR SECTION FAULT FOR LINES EQUIPPED WITH REPEATERS
- symbolic output name or parameter value
- status value for a digital subscriber access
DLIM TIME LIMIT ON USE OF THE SERVICE
- Parameter symbolic name
- In the form yyyy-hh-mm
DMA MODEM PRESENT ON THE IT
- Symbolic name of parameter output
DMG ENTITLEMENT TO HOLD-ON FACILITY
- Value of parameter CAT
DMNT "UNLOAD" OPTION FOLLOWING FILE CLOSURE
- Symbolic name of parameter
- Possible values :
- O (YES) or N (NO)
- (O : implicit value )
DMO ENTITLEMENTS TO MODIFICATIONS
- Symbolic parameter name.
- Possible values :
• EXP : Can be customized as a whole by the operator
• SEXP : Can be customized site by site by the operator
• CTR : Can be customized as a whole by the manufacturer
• SCTR : Can be customized site by site by the manufacturer
• NOP : Cannot be customized.
DMP THRESHOLD VALUE OF SEIZURE AVERAGE DURATION (SEC)
- Symbolic name of parameter
DMP THRESHOLD VALUE OF SEIZURE AVERAGE DURATION (SEC)
- Symbolic name of parameter
DMV STATION FORCED BUSY
- Value of parameter TY (CENTREX)
DND DO NOT DISTURB
- CAT parameter value
DNR DIVERSION ON NO ANSWER
- CAT parameter value
DNUM DIALLING DURATION
- Symbolic name output
DNUS Do not use for synchronization

3BW 45305 AAAA RKAHA Ed. 07 67 / 236


SYMBOL DICTIONARY

- Value of the parameter TIMQ


DN1 STANDARDIZED DISCRIMINATION
- Parameter value CAT
DOB ASSIGNMENT DOMAIN OF SATELLITE ALARM COUPLER
- Output symbolic name
- Possible values :
• 0 : Satellite coupler of an SM
• 1 : Satellite coupler of a station not connected to the MIS-MAS
• 2 : Satellite coupler of the SMM
• 3 : Satellite coupler outside the SMM
• 4 : Satellite coupler of the SMM, dedicated to remote control
• 5 : Satellite coupler outside the SMM, dedicated to remote control
DPi NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
- Possible value: 1 ≤ i ≤ 7
DPND RIGHT TO CALLING NAME IDENTIFICATION PRESENTATION
- Value of the CAT parameter
DP1 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
DP2 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
DP3 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
DP4 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
DP5 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS
DP6 NON-DEDICATED PREANALYSIS DISCRIMINATION
- Parameter value
- Parameter : DIS

68 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DP7 NON-DEDICATED PREANALYSIS DISCRIMINATION


- Parameter value
- Parameter : DIS
DQAn NON-DEDICATED DISCRIMINATIONS
- Value of parameter TY
DQBi STANDARD EQUIPMENT CLASS OF SERVICE
- TY parameter value
- 1≤i≤7
DQF BB 4-WIRE-DEDICATED ACCESS EQUIPMENT
- Symbolic name output
DQF04 4-EQUIPMENTS TU USING 2/4 AF WIRES
- Value of parameter
DQ1 STANDARDIZED EQPT DISCRIMINATION
- Value of parameter TY
DQ2 STANDARDIZED EQPT DISCRIMINATION
- Value of parameter TY
DQ3 STANDARDIZED EQPT DISCRIMINATION
- Value of parameter TY
DR TESTER DISCONNECTION
- Value of parameter
- Must precede phases P5 or P6
DRAi NON-DEDICATED DISCRIMINATIONS
- Value of parameter DIS
- 1 ≤ i ≤ 15
DRBi NON-DEDICATED DISCRIMINATIONS
- Value of parameter DIS
- 1 ≤ i ≤ 15
DRCi NON-DEDICATED DISCRIMINATIONS
- Value of parameter DIS
- 1 ≤ i ≤ 15
DRI1 Service trigger routing code
- Value of DIS parameter
DRI2 Service trigger routing code
- Value of DIS parameter
DRI3 Service trigger routing code
- Value of DIS parameter

3BW 45305 AAAA RKAHA Ed. 07 69 / 236


SYMBOL DICTIONARY

DRI4 Service trigger routing code


- Value of DIS parameter
DRI5 Service trigger routing code
- Value of DIS parameter
DRI6 Service trigger routing code
- Value of DIS parameter
DRI7 Service trigger routing code
- Value of DIS parameter
DRI8 Service trigger routing code
- Value of DIS parameter
DRI9 Service trigger routing code
- Value of DIS parameter
DRI10 Service trigger routing code
- Value of DIS parameter
DRI11 Service trigger routing code
- Value of DIS parameter
DRI12 Service trigger routing code
- Value of DIS parameter
DRI13 Service trigger routing code
- Value of DIS parameter
DRI14 Service trigger routing code
- Value of DIS parameter
DRI15 Service trigger routing code
- Value of DIS parameter
DRI16 Service trigger routing code
- Value of DIS parameter
DRI17 Service trigger routing code
- Value of DIS parameter
DRI18 Service trigger routing code
- Value of DIS parameter
DRI19 Service trigger routing code
- Value of DIS parameter
DRI20 Service trigger routing code
- Value of DIS parameter
DRI21 Service trigger routing code
- Value of DIS parameter

70 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

DRI22 Service trigger routing code


- Value of DIS parameter
DRI23 Service trigger routing code
- Value of DIS parameter
DRI24 Service trigger routing code
- Value of DIS parameter
DRI25 Service trigger routing code
- Value of DIS parameter
DRI26 Service trigger routing code
- Value of DIS parameter
DRI27 Service trigger routing code
- Value of DIS parameter
DRI28 Service trigger routing code
- Value of DIS parameter
DRI29 Service trigger routing code
- Value of DIS parameter
DRI30 Service trigger routing code
- Value of DIS parameter
DRI31 Service trigger routing code
- Value of DIS parameter
DRI32 Service trigger routing code
- Value of DIS parameter
DROC ENTITLEMENT TO AUTOMATIC CALL-BACK ON BUSY CALLED PARTY
- Value of parameter CAT
DRV ENTITLEMENT TO ALARM OR APPOINTMENT CALLS
- TY parameter value
DR1 NON-DEDICATED ROUTING DISCRIMINATIONS
- Value of parameter DIS
DR2 NON-DEDICATED ROUTING DISCRIMINATIONS
- Value of parameter DIS
DR3 NON-DEDICATED ROUTING DISCRIMINATIONS
- Value of parameter DIS
DR4 NON-DEDICATED ROUTING DISCRIMINATIONS
- Value of parameter DIS
DR5 NON-DEDICATED ROUTING DISCRIMINATIONS
- Value of parameter DIS

3BW 45305 AAAA RKAHA Ed. 07 71 / 236


SYMBOL DICTIONARY

DSE HALF ECHO-CANCELLATION ON


- Value of parameter CTA
DSI SERVICE SIGNATURE DATE
- Parameter symbolic name
- In the form of a decimal string ’yyyymmddhhmmss’
DSK RESERVATION OF DISK SPACE FOR FILE
- Symbolic parameter name
- Possible values for the following command :
• ARCAD :
- YES Space on the disk for the file is reserved
- NO Space on the disk for the file is not reserved
DSM SIGNALLING-CAPABLE LINE IN MESSAGE MODE
- Value of the TY parameter
DSO RINGING time
- Symbolic name of parameter
- Possible values : 0 to 99
DSO CALL RINGING DURATION
- Symbolic name printed out
- Value indicated in seconds
DSRQ ENTITLEMENT TO STATUS REQUEST PROCEDURE (CCBS)
- Value of parameter TY
FSC MARQUED DESTINATIONS
- Value of parameter ENT
DS1 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS2 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS3 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS4 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS5 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS6 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DS7 NON-DEDICATED COMPANY DISCRIMINATIONS

72 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter CAT


DS8 NON-DEDICATED COMPANY DISCRIMINATIONS
- Value of parameter CAT
DT TRAFFIC DELAY PRESENCE
- Symbolic name for output
- Data read from the magnetic tape of detailed billing type
- Possible values:
• Character Y (for yes) or N (for no)
DTC ENTITLEMENT TO CHARGE METERING FOR THE CIRCUIT
- Value of parameter CTA
DTMF__ line supportind dual tone multi frequency
- Value of parameter TY for subscriber management
DTNR TNR FAULT
- symbolic output name or parameter value
- status value for a digital subscriber access
DUPL DUPLICATION OF ARCHIVE OR OM FILE
- Symbolic parameter name
DUR CALL DURATION
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal value in 8 digits
DUREE MEASUREMENT DURATION AT COMPONENT LEVEL
- Symbolic name printed out.
DV NAME OF PROCESSOR PERIPHERALS
- Symbolic name of parameter
- The possible values are : TYn, CVn, IRn, BMn, STA
DV NAME OF PROCESSOR PERIPHERALS
- Symbolic name of parameter
- The possible values are : TYn, CVn, IRn, BMn, STA
DVAL DISABLING
- Parameter value.
- Request for reference file disable, leading to its change-over with the corresponding
work file.
DV1 CLASS OF SERVICE CATEGORY 1
- DIS parameter value
DV2 CLASS OF SERVICE CATEGORY 2

3BW 45305 AAAA RKAHA Ed. 07 73 / 236


SYMBOL DICTIONARY

- DIS parameter value


DV3 CLASS OF SERVICE CATEGORY 3
- DIS parameter value
DV4 CLASS OF SERVICE CATEGORY 4
- DIS parameter value
DV5 CLASS OF SERVICE CATEGORY 5
- DIS parameter value
DV6 CLASS OF SERVICE CATEGORY 6
- DIS parameter value
DV7 CLASS OF SERVICE CATEGORY 7
- DIS parameter value
DV8 CLASS OF SERVICE CATEGORY 8
- DIS parameter value
DV52 FAULT BEYOND THE INTERFACE V5.1
- symbolic output name or parameter value
- STATUS OF THE PARAMETER "ETAT" FOR THE COMMAND ABFASE
DV52 FAULT BEYOND THE INTERFACE V5.2
- symbolic output name or parameter value
- STATUS OF THE PARAMETER "ETAT" FOR THE COMMAND ABFASE
D1 DATE OF START OF INTERVAL TO BE PRINTED OUT
- Symbolic name of parameter
- On the form YY-MM-DD
D1H1 START DATE OF TIME SLOT TO BE OUTPUT
- Symbolic name of parameter
- In the following form YY QQQ HH
- YY = Year
- QQQ = Day (of the year)
- HH = Hour
D2 DATE OF END OF INTERVAL TO BE PRINTED OUT
- Symbolic name of parameter
- On the form YY-MM-DD
D2F 2-WIRE DISCRIMINATED EQUIPMENT (IB + TTX)
- Output symbolic name
D2F08 2-WIRE DISCRIMINATED EQUIPMENT
- Symbolic name printed out
D2H2 END DATE OF TIME SLOT TO BY OUTPUT

74 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- In the following form YY QQQ HH
• YY = Year
• QQQ = Day (of the year)
• HH = Hour
D3F 3-WIRE DISCRIMINATED EQUIPMENT (IB+TTX)
- Symbolic name output
D3F08 3-WIRE DISCRIMINATED EQUIPMENT
- Symbolic name printed out
E EXCLUSIVE
- Symbolic name printed out
- Used in direct calls
E I/C CIRCUIT GROUP
- Value of parameter
Ei UNIT CONCERNED BY THE LOCATION
- Value of the ENS parameter for the URA2G
- 1 ≤le i ≤le 255
E INCOMING CALLS
- Value of parameter SENS
E TRANSMISSION (DIRECTION)
- Parameter value
Ei TYPE E
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15
E EBCDIC
- Parameter value.
E END CHARACTERISTICS
- Parameter value
EA SELECTION OF THE SIGNALS INTERCHANGED DURING THE CALL SET-UP PHASE
- Value of parameter MOD
EC ECHO CANCELLATION FUNCTION
- Value of the parameter FACT
ECA NUMBER OF LLP ACTIVATION FAILURES DUE TO OTHER CAUSES
- Symbolic name in output lists
ECH FAILURE SIGNAL
- Value of IEC parameter

3BW 45305 AAAA RKAHA Ed. 07 75 / 236


SYMBOL DICTIONARY

ECHO NUMBER OF BYTES EXCHANGED BETWEEN PABXS


- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal number in no more than 8 digits
ECHOLi DURATION OF THE TEMPORARY ECHO PROCESSING WINDOW
- Value of the parameter AECHO
- The possible values are as follows:
- i=1 duration of 64 milliseconds (default value)
- i=2 duration of 48 milliseconds
- i=3 duration of 32 milliseconds
- i=4 duration of 16 milliseconds
ECN NUMBER OF LLP ACTIVATION FAILURES DUE TO NUMBER OF LLPs
- Symbolic name in output lists
ECOUT LISTENING IN OF TONES EXCHANGED (CIRCUIT TESTING)
- Symbolic name of parameter
- Possible values : O (YES) or N (NO)
ECSP RESULT OUTPUT CNSPE/CNSPE OR GLOBALLY PER CNSPE GRP
- Symbolic name of parameter
- Possible values : YES or NO
- ECSP=YES : result output CNSPE after CNSPE
- ECSP=NO : result output per CNSPE group
- Implicit value : NO
ECT ENTITLEMENT TO EXPLICIT CALL TRANSFER
- Value of the CAT parameter
ECTI ENTITLEMENT TO EXPLICIT CALL TRANSFER TO INTERNATIONAL LINE
- Value of the CAT parameter
ED PRINTOUT
- Symbolic name of parameter
- Possible values : YES - NO
ED DETAILED EDITION
- Symbolic parameter name
- Possible values : YES, NO.
ED PARAMETERS LINE PRINTOUT OPTION
- Symbolic name of parameter
- Parameter without any value attributed

76 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

ED REQUEST FOR PRINTOUT


- Symbolic name of parameter
- Possible values : O (YES) or N (NO)
ED PRINTOUT OF QUALITY COUNTER
- Symbolic name of parameter
- possible value : YES
ED PRINTOUT INDICATOR OF THE LIST OF EQUIPMENT
- Symbolic name of parameter
- Possible values: YES - NO
- (NO is implicit)
ED DIARY OUTPUT
- Symbolic name of parameter
- Possible value : YES
- Parameter present : output of time of appointments for every day of the week
- Parameter absent : output of time of appointments for current day
ED REQUEST FOR PRINTOUT
- Symbolic name of parameter
- Possible values : O (YES) or N (NO)
ED EDITION OF ALL RESULT
- Symbolic name of parameter
- possible value : NUL
EDAR NAME OF FAULTS FILTER
- Value of parameter
- Name of the filter which contains the selection
- Standards for printoud - under operator’s control of the latest fault stored
EDAV NAME OF FAULTS FILTER
- Value of parameter
- Name of the filter which contains the selection standard of the faults to be printed out
as they come
EDI OUTPUT OF THE TAPE CONTENT
- Symbolic name of parameter
- Parameter 1 : block number = 0 to 80
- Parameter 2 : length to be output = 0 to 80
EDN STANDARD (STD) WITH OUTPUT OF NULL VALUE FIELDS
- Parameter value
EDSSUR REMOTE ISUP AVAILABILITY
- Symbolic name being output

3BW 45305 AAAA RKAHA Ed. 07 77 / 236


SYMBOL DICTIONARY

- Possible values : DISPO (available) or INDISPO (unavailable)


EFF O/G TRAFFIC OBSERVATION EFFICIENCY RATE
- Symbolic name printed out
- Efficiency rate at the output of the exchange,together with efficiency rate from sub-
scriber viewpoint for each routing code under observation
EFF COMMAND DELETION
- Symbolic name of parameter
- Possible value : 0 ≤ EFF ≤ 1
EFF DISK BLOCK ERASURE
- Value of parameter OPT
- Erasure of blocks already archived on disk (intemized billing or fault - alarm - obser-
vations - TAXIL).
EFF DISK BLOCK ERASURE
- Value of parameter
- Erasure of blocks already archived on disk
EFF TYPE OF ALARM: BURGLARY
- Parameter value
EFFAC OPTION FOR AUTOMATIC ERASURE OF BLOCKS
- Symbolic name of parameter
EFFAC DELETION OF PMD OR NOT FROM DISK FOLLOWING PMDSV
- Symbolic name of parameter
- The possible values are:
- YES, PMD backup on tape only
- NO, PMD backup on tape with possibility of unlimited operation repetition.
EFR "BURGLAR" ALARM
- Symbolic name printed out
EHS EQUIPMENT OUT-OF-SERVICE
- Symbolic name printed out
ELT TYPE OF ITEM
- Parameter symbolic name:
- possible values: 1 ≤ ELT ≤ 5
- ELT = 1 board
- ELT = 2 surface-mounted type
- ELT = 3 backplane
- ELT = 4 upper fan unit
- ELT = 5 lower fan unit
EM ANOMALY TRANSMITTER UNIT

78 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name printed out


EM TRANSMISSION OF A MESSAGE WITHOUT ANSWER
- Value of parameter
EMAL LOCAL SUBSCRIBER MODULATION EQUIPMENT
- Symbolic name printed out
ENBM NAME OF FAULTS FILTER
- Value of parameter
- Name of the filter which contains the selection standards of the faults to be recorded
on magtape as they occur.
ENC FRAME AROUND MESSAGES
- Symbolic name of parameter
- Possible value :
• YES : frame around messages (Value by default)
• NO : no frame around messages
ENC CONGESTION SIGNAL
- Value of IEC parameter
END END OF PROCESSING FUNCTION
- Value of parameter
FIN END OF PROCESSING FUNCTION
- Parameter value
FIN END OF LISTING
- Parameter value
FIN INTERRUPT FACILITY
- DIS parameter value
END END OF PROCESSING
- Parameter value
END END OF FREE SPACE
- Parameter value
ENE POWER ALARM
- Symbolic name printed out
ENG EQUIPMENT ENGAGED
- Value of parameter STTUS
ENGA EQUIPMENT Nº 7 ENGAGED AT INPUT
- Value of parameter STTUS
ENGD EQUIPMENT Nº 7 ENGAGED AT OUTPUT
- Value of parameter STTUS
ENP TYPE OF ALARM: PRIMARY POWER

3BW 45305 AAAA RKAHA Ed. 07 79 / 236


SYMBOL DICTIONARY

- Parameter value
ENR MEASUREMENT OF RAPIDE REGISTERS
- Symbolic name of parameter
- ENR = YES
ENS HARDWARE MODULE TESTED BY LOCAVAR
- Symbolic name of parameter
- Values of parameter :
• Connection units :
- CSE : MICi : PCM shelf i (0 ≤ i ≤ 3)
- ANX : annex modules (transponders, alarms,
- security local calls)
- ABN : all subscribers
- CABNi : subscriber card i (0 ≤ i ≤ 127)
- CABNi,NB=j : subscriber cards i to i+j (1 ≤ j ≤ 128)
- MCBi : XMCB pair i (0 ≤ i ≤ 7)
- CDE : standby control logic
- CSN : CDE : standby control logic
- CN : all cards of all CN concentrators of a CSN
- MICi : PCM link i to E10 (0 ≤ i ≤ 15)
- MUXi : (de)multiplexing function of the TCTROi (0 ≤ i ≤ 1)
- CN : CN : All UT of a CN concentrator
- MICi : TTRSi or TCTRS of ICNE, and, TTRSi or TCMHL of CNE
- (0 ≤ i ≤ 3)
- UTi : testing of terminal unit i (0 ≤le i ≤ 16)
- UTi,NB=j : testing of terminal units i to i + j (1 ≤le j ≤ 17)
- URA2G : Ei : unit (1 ≤ i ≤ 255)
ENS TYPE OF ALARM: SECONDARY POWER
- Parameter value
ENT OBSERVED ENTITIES
- Symbolic name of parameter
- Possible values : MIS, MAS1, MAS2, MAS3, MAS4, RPTC, RPTR, RSC, TRI, RSS, RSL
ENT ENTITY FOR LISTING
- Symbolic parameter name
- Possible values are:
• FSC Telephonic circuit group.
• FSM Signalling link set.

80 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• DST Destinations.
EOF POSITIONING BEHIND LAST BLOCK OF LAST FILE
- Value of parameter
EOV POSITIONING BEHIND LAST FILE
- Value of parameter
EQCn CSN (SWITCHABLE) EQUIPMENT EQUALIZATION
- Value of parameter TY
- Possible values : 1 < n < 3
EQUIP TYPE OF SECONDARY EQUIPMENT CONNECTED TO THE OM
- Symbolic name of parameter.
- The possible value are :
- RIEN, ARD, ARDS.
ERLi ECHO ROUTE ATTENUATION NATURAL THRESHOLD
- Value of the parameter AECHO.
- Possible values:
- i=1 6 DB threshold (default value)
- i=2 3 DB threshold
- i=3 0 DB threshold
ERL MEASUREMENT OF ECHO RECEIVED
- Symbolic name of parameter output
ERLE MEASUREMENT OF EFFECTIVENESS OF THE ECHO CANCELLER.
- Symbolic name of parameter output
ERR TAPE ANALYSIS RELATED TO INCORRECT BLOCKS
- Value of parameter
ES OPERATING EQUIPMENT
- Value of parameter
ES CONTROL STATION IN SERVICE
- Parameter value
- ETAT (STATUS) or symbolic name in an output line
ES MULTIPLEX RING IN OPERATION
- Parameter value
NES ET NOT IN SERVICE
- Parameter setting
- STATUS or symbolic name in an output line
- ET not handling traffic
ES IN SERVICE

3BW 45305 AAAA RKAHA Ed. 07 81 / 236


SYMBOL DICTIONARY

- Parameter value
ESALM ES NON OPERATIONAL, IN STATE OF ALARM
- Value of the parameter STTUS (ETAT) of the command ETTIL
ESBLD ES NON OPERATIONAL, BLOCKED REMOTELY
- Value of the parameter STTUS (ETAT) of the command ETTIL
ESFAU ES NON OPERATIONAL, IN STATE OF FAULT
- Value of the parameter STTUS (ETAT) of the command ETTIL
ESP Value ’20’H for the path trace stuffing bytes
- Value of the parameter PTFIL
ESP INDICATOR OF TOTAL CALL LIMITATION
- Symbolic name of parameter
- Possible value : TOT
ESRE SOFTWARE MACHINE IN OPERATION AS STANDBY
- Parameter value
- The ML is operating as the "standby" of one or several other MLs.
ESREG EQUIPMENT IN REGENERATION SERVICE
- Value of parameter
ESRES EQUIPMENT IN RESTRICTED SERVICE
- Value of parameter
ET The ET address
- Symbolic name of parameter
- Under the form <Nº TU>-<Nº ET> with :
• TU : Terminaison unit (1<=TU<=128)
• ET : Terminal equipment (1<=ET<=2)
ETA FREQUENCY SENDER/RECEIVER UNIT i ML GROUP
- Parameter value
ETAi FREQUENCY SENDER/RECEIVER UNIT ML GROUP i
- Parameter value (1 ≤le i ≤le 64)
ETAi ETA i TIME CHOSEN AS SYSTEM TIME
- Output symbolic name (1 ≤le i ≤le 2)
ETA ML ETA
- TYML parameter value
ETCS SIGNALLING LINK STATUS
- Symbolic name of parameter
- Sequence of two symbols:
- Activity instruction + isolation instruction

82 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values of the activity instruction:


• INAC : inactive
• ACTI : active
• NAFF : not allocated
• NCNT : unconnected
• INIT : initialization under way
- Possible values of the isolation instruction:
• NBLO : not blocked
• BLOM : manually and locally blocked
• BLOS : system-controlled local blocking
• BLOD : output manual blocking
• BLOT : complete blocking
ETET ET STATUS
- Symbolic name of parameter
- Parameter settings :
- ES : In service
- NEQ : Not present
- INDO : Unavailable busy
- INDL : Unavailable free
- NES : Not in service
- NAFF : Not assigned
ETH 10 MBIT/SEC. ETHERNET
- SFCA and SFEM parameter value
ETMND NON DUPLICATED MODULES STATUS
- Symbolic name printed out
ETP EXCHANGE TERMINAL PROCESSOR
- SFEM parameter value
ETRSV STATE OF AN ALARM MULTIPLEX STANDBY RING
- Symbolic name printed out
- Appears in case of a divergence between the two ring statuses in an alarm multiplex
- Possible values : BLOM, BLOS, ES, INDL
ETRSV STATUS OF STANDBY RING OF AN ALARM MULTIPLEX
- Output symbolic name
- Appears when there is a status discrepancy between the two rings of an alarm multi-
plex.
- Possible values
- BLOM, BLOS, ES, INDL

3BW 45305 AAAA RKAHA Ed. 07 83 / 236


SYMBOL DICTIONARY

ETU EQUIPMENT TERMINATION UNIT NUMBER


- Symbolic parameter name
- Possible values : if station is SCH or SMT,1 to 32
- Possible values : if station is SMB, 1 to 128
ETU EXCHANGE TERMINATION UNITS
- Value of parameter SFCA
EVT RELIABILITY MONITORING EVENT
- Symbolic parameter name
- Use the parameter HELP to view the possible values and the meaning of each.
- SRFIL input
- Number
- Output
- <Number>:<label>
EXC END OF PROCESSING EXECUTION
- Symbolic name printed out
EXLS ACCESS EXCLUSIVELY BASED ON LS
- Value of parameter TY
EXP TYPE OF ALARM: EXPLOSIMETER
- Parameter value
EXP CAN BE CUSTOMIZED AS A WHOLE BY THE OPERATOR
- Parameter value
EXPE EXPERIMENTAL PHASE OF REMOTE UNIT CONNECTION
- Value of parameter
EXTR LIMIT
- Symbolic name of parameter
- Possible values : IRS or URAD
- If the parameter is omited, the swith over is carried out at the URAD level.
F FUNCTION OF A FAULT MESSAGE
- Symbolic name printed out
- Possible values : 0 to 15
F MALFUNCTION MESSAGE FUNCTION
- Output symbolic name
- Possible values from 0 to 15
Fi TYPE F
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15

84 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

F CIRCUIT GROUP
- Value of parameter
FA PERMANENT CONDITION
- Symbolic name printed out
FACT ECHO CANCELLER FUNCTIONS
- Parameter symbolic name
- The possible values are as follows:
- TMIC: PCM termination function (default value)
- TMIC + EC: PCM termination function, and echo cancellation
- TMIC + SIG5: PCM termination function, and code line 5 signaller
- TMIC + EC + SIG5: PCM termination function, echo cancellation, and code line 5
signaller
FAL ANNOUNCEMENT OF END OF ALARM
- Symbolic name printed out
FAUA EQUIPMENT Nº 7 FAULTY AT INPUT
- Value of parameter STTUS
FAUD EQUIPMENT Nº 7 FAULTY AT OUTPUT
- Value of parameter STTUS
FAUT NUMBER OF ERROR DETECTED
- Symbolic name printed out
- (the circuit busying is considered an error, FAUT = 0)
FCARTE FAULT ON BOARD DETECTED DURING LCXE CHECKS
- Symbolic name at output
FCDL FILE AND ARCHIVE BACKUP WITH THE "CHANGE OF SOFTWARE" DISCRIMINATOR
- Parameter value
FCDP FILE AND ARCHIVE BACKUP WITH THE "CHANGE OF RELEASE" DISCRIMINATOR
- Parameter value
FCP POINT CODE FORMAT
- Parameter code
- Possible values:
• 0 : purely 14 bit network
• 1 : purely 24 bit network
• 2 : 14/24 bit dual mode network
FCT INTERCHANGE FUNCTION
- Symbolic name of parameter
- Possible values :
- PO, PC, LO, EM, RI, RD, RC, LC, RB.

3BW 45305 AAAA RKAHA Ed. 07 85 / 236


SYMBOL DICTIONARY

FCT TYPE OF LR ON SMB_A


- Symbolic output name
- Possible values :
• N7 - Nº 7 signaling system
• GT - Tone generator
• RGF - Frequency receiver and generator
• CCF - Conference circuit
• V23 - V23 modulator-demodulator
• AN - V5.2 and/or PRAD AN
FDn ENTITLED TO DETAILED INVOICING
- Value of parameter CAT
- Possible value :1 ≤ n ≤ 7
- Refer to operating data
FD DETAILED BILLING RECORD
- Value of parameter
- Type for magnetic tape read
FDn FILTERING ON SATURATION CHANNEL OF 1 TO 7 CALL OUT OF 8
- Value of parameter
- Possible values : 1 to 7
FDn CLASS OF DETAILED BILLING FOR INCOMING CIRCUIT GROUPS
- Value of parameter CTA
- Default value FD0 : No detailed billing
- Possible values : 1 ≤ n ≤ 7
FDAT DATA EXCEPT CATALOGUE
- Parameter value
- Used to save all files except FIAF and FCDF from the exchange archive.
FDS MEASUREMENT ACCORDING TO DESTINATION
- MAR parameter value
FE SELECTION OF ALL SIGNALS BY BURST OF x MESSAGE (0<x<5)
- Value of parameter MOD
FEN INTERAID FAULT
- Parameter value
FENU NUMBER OF FILE FENU
- Symbolic name of parameter
- Possible values : from 1 to 16
FESS RELEASE OF MANUAL TEST

86 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


FIC OUTPUT ON THE LEVEL OF FILES
- Parameter value
FIC FILE AND ARCHIVE REGENERATION
- Parameter value
FICD NAME OF DESTINATION FILE
- Symbolic parameter name
- Possible values :
- For an archive file : 4 to 6 characters
- For an OM file : 4 characters (this is the LFN)
FICDM NAME OF PHYSICAL FILE (DISK)
- Symbolic name of parameter
FICH FILE NAME
- Symbolic name of parameter
- Possible values:
• file name on four characters
• additional ESYMO command specific value: STD, meaning "all files having a
work area"
• additional SITRG command specific value: ALL, meaning "all files present on
tape"
FICH FILE NAME
- Symbolic name of parameter
FICS NAME OF SOURCE FILE
- Symbolic parameter name
- Possible values :
- For an archive file : 4 to 6 characters
- For an OM file : 4 characters (this is the LFN)
FIE ENTITLED TO SECRETARIAL CALL PICK-UP
- Value of parameter CAT
FIE ENTITLED TO SECRETARIAL CALL PICK-UP
- Value of parameter CAT
FIL FILTERING CONDITION
- Symbolic name of parameter
- Possible values : NF, FT, FV, FPn, FDn
• NF : not filtered (no restriction)
• FT : total filtering (total restriction)
• FP1 to FP7 : partial filtering of 1 to 7

3BW 45305 AAAA RKAHA Ed. 07 87 / 236


SYMBOL DICTIONARY

• calls out of 8 (partial restriction)


• FD1 to FD7 : filtering on overflow channel of 1 to 7 calls out of 8
• (partial overflow restriction of rank 1 to 8)
• FV : total filtering of the channel (channel restriction)
FILM NUMBER OF RECORDED MESSAGE
- Symbolic name of parameter
- Possible values :
• from 1 to 120 in ACHCR, ACHMO, ACHIL
• from 1 to 30 in ESALA, ESAMO, DIFIL
• from 0 to 15 in FILMO
FILMn LOGICAL NUMBER OF RECORDED ANNONCEMENT
- Value of parameter DISLD
- Possible values :
• from 1 to 30 (Subscriber function)
• from 1 to 127 (CAS function)
FILMi LOGICAL NUMBER OF RECORDED ANNONCEMENT
- Parameter value
- Possible values :
• from 1 to 30 (Subscriber function)
• from 1 to 127 (CAS function)
FINU End of dialling
- Value of the DIS parameter
FIO PRIVATE CIRCUIT GROUP LIABLE TO BE SUBJECT TO AUTOMATIC CALL BACK
- Value of parameter CTA
FIP PREFERENTIAL CALL PICK-UP STATION
- Value of parameter MAR (CENTREX)
FIR ENTITLED TO PICK UP CALLS
- Value of parameter CAT
FIR ENTITLED TO PICK UP CALLS
- Value of parameter CAT
FITX CHARGE RESTRICTION CODE
- Value of the DIS parameter
FLA FAULT ON LA LINK
- Symbolic name at output
FLA TELEPHONE SET EQUIPPED WITH FLASH BUTTON
- Value of parameter TY

88 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

FLA FAULT ON LINK LA


- Symbolic name of parameter
FLA LA LINK FAULT
- Parameter value
FLCXE FAULT ON LCXE LINK
- Symbolic name at output
FLC32 UT HAVING 32 EQUIPMENTS WITH "C" WIRE
- Value of parameter
FLMi NUMBER OF THE ANNOUNCEMENT TO BE CONNECTED
- PARAM parameter value
- i is between 1 and 127
FLR FAULT ON LINK LR
- Symbolic name of parameter
FLR LR LINK FAULT
- Parameter value
FLREi LREi LINK FAULT
- Parameter value
- Possible values: 1 ≤ i ≤ 8
FLRE1 FAULT ON LINK LRE1
- Symbolic name of parameter
FLRE2 FAULT ON LINK LRE2
- Symbolic name of parameter
FLRE3 FAULT ON LINK LRE3
- Symbolic name of parameter
FLRE4 FAULT ON LINK LRE4
- Symbolic name of parameter
FLRE5 FAULT ON LINK LRE5
- Symbolic name of parameter
FLRE6 FAULT ON LINK LRE6
- Symbolic name of parameter
FLRE7 FAULT ON LINK LRE7
- Symbolic name of parameter
FLRE8 FAULT ON LINK LRE8
- Symbolic name of parameter
FLRS FAULT ON LINK LRS
- Symbolic name of parameter

3BW 45305 AAAA RKAHA Ed. 07 89 / 236


SYMBOL DICTIONARY

FLRS LRS LINK FAULT


- Parameter value
FLUX REGULATION MODE BETWEEN OM AND SECONDARY EQUIPMENT
- Symbolic name of parameter.
FMP HOLDING FUNCTION POSSIBLE
- Value of parameter CTA
FON NON-PROCESSED FLOWS
- Value of OPT parameter
FNT FORMAT OF NUMBER TO BE SENT
- DIS parameter value
FON NAME OF FUNCTION TO BE ACTIVATED
- Symbolic name of parameter
- For MMURA, the parameter may take the following values:
- INI Initialization phase
- GCUR Mapping
- GABO Data conversion
- MAJ Archive update
- TRF Data transfer
- For MMCDP, the parameter may take the following values:
- GTR Transition of translator from Pn to Pn+1
- GTX Transition of charging unit from Pn to Pn+1
- GMQ Transition of marker from Pn to Pn+1
- GABO Update of subscriber-modifiable data
FONC NAME OF FUNCTION TO BE ACTIVATED FOR INCOCT
- Symbolic name of parameter
- LABO Listing of inconsistencies related to subscribers
FONC FUNCTION
- symbolic name of parameter.
- Possible values :
- LIST list function.
- INIT initialization function.
- COPY copy function.
- RECH search event function .
- MODI modify function.
FORC PRESETTING LINE TESTS ON AN ACCESS PROVIDED WITH LLP
- Symbolic name of parameter

90 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

FORM TYPE OF PRINTED OUT FORMAT


- Symbolic name of parameter.
- Mnemonics :
• STR, CHK, CHKA, SPCi ( 1 <= i <= 8).
- Value ’by default’ : FORM = SPC1.
FORM OUTPUT FORMAT TYPE
- Symbolic parameter name
- Possible values :
• AUT
• Output according to the format associated with the structure.
• STD
• Standard output in the form <field> = <value>.
• HEX
• Output in dump form.
• EDN
• Standard with output of null value fields.
- Default value : FORM = STD
FPn PARTIAL FILTERING OF 1 TO 7 CALLS OUT OF 8
- Value of parameter
- Possible value : 1 ≤ n ≤ 7
FRIn NON-DEDICATED CATEGORY FOR IN-CS1 SERVICES ACCESS
- Value of parameter CTA
- 1 ≤ n ≤ 32
FRM FORMAT NUMBER
- Symbolic name of parameter.
FRMD DESTINATION FORMAT NUMBER
- Symbolic name of parameter.
FRMS SOURCE FORMAT NUMBER
- Symbolic name of parameter.
FS Forced switch
- Value of the parameter REQ
FSC LISTING CHARGEABLE CIRCUIT GROUPS
- Symbolic name of parameter
- The parameter may take the values YES
- (list chargeable circuit groups),
- or NO (list routing codes)

3BW 45305 AAAA RKAHA Ed. 07 91 / 236


SYMBOL DICTIONARY

FSC IDENTIFICATION OF OUTGOING CIRCUIT GROUP


- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value 4 digits maximum
FSC MARQUED CIRCUIT GROUP
- Value of parameter ENT
FSLDn NUMBER OF LINK SET TO WHICH BELONGS A DATA LINK
- Value of parameter DISLD
- possible value : 0
FSLD NUMBER OF LINK SET TO WHICH BELONGS A DATA LINK
- Symbolic name on output
- possible value : 0
FSM SIGNALLING LINK SETS
- Value of the parameter ENT
FSTPD FORCED SWITCH TO PROTECTED
- Value of parameter REQ
FSTPG FORCED SWITCH TO PROTECTING
- Value of parameter REQ
FT TOTAL FILTERING
- Value of parameter
FV CHANNEL TOTAL FILTERING
- Value of parameter
FXA PERMANENT CONDITION
- Symbolic name printed out
GABAn SUBSCR. LINE OR RESPONDER REFERENCE PARAM. NUMBER
- Symbolic name of parameter
- Number 0 = transponder calibration
- 1 ≤ n ≤ 8 = line calibration(implicit value : GABA1)
GABAn SUBSCRIBER LINE CALIBRATION
- Value of parameter
- 1 ≤ n ≤ 8 (Implicit value : GABA1)
GABC CIRCUIT CALIBER NUMBER
- Symbolic name of parameter
- Possible values :
- In, Un, Sn, Rn, Pn, Nn, AAn, Bn,
- Cn, Dn, En, Fn.

92 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

In : 1 ≤ n ≤ 15
- Un : 1 ≤ n ≤ 15
- Sn : 1 ≤ n ≤ 15
- Rn : 1 ≤ n ≤ 15
- Pn : 1 ≤ n ≤ 15
- Nn : 1 ≤ n ≤ 15
- AAn : 1 ≤ n ≤ 15
- Bn : 1 ≤ n ≤ 15
- Cn : 1 ≤ n ≤ 15
- Dn : 1 ≤ n ≤ 15
- En : 1 ≤ n ≤ 15
- Fn : 1 ≤ n ≤ 15
GABO START OF THE GABO PHASE FOR MMCDP
- PARAMETER VALUE
GEN NEW PHASE DATA GENERATION
- Value of parameter
GENR KIND OF CIRCUIT GROUP
- Symbolic name of parameter
- Take the values :
• S (O/G)
• E (I/C)
• M combined
• TD data transmission
GENR KIND OF CIRCUIT
- Symbolic name printed out
GFD NUMBER OF DETAILED BILLING TRAFFIC GROUP
- Symbolic name of parameter
GFU RIGHT TO ACCESS THE CUG SERVICE (CLOSED USER GROUP)
- Value of the CAT parameter
NGGLR1 FIRST GLR GROUP TO ASSIGN TO A TCA ETU.
- Parameter symbolic name
- Can vary from 0 to 255, by default assigned automatically.
GIAn CALL INTERCEPTION GROUP
- Value of parameter CAT
- 1 ≤ n < 4095
GLCOE AUTOMATIC OPERATION/COEFFICIENTS FREEZE

3BW 45305 AAAA RKAHA Ed. 07 93 / 236


SYMBOL DICTIONARY

- Parameter symbolic name


- Possible values:
- YES : freeze coefficients
- NO : automatic operation (default value)
GLRA GLR NUMBER IN THE SMB-A
- Parameter symbolic name
- Possible value : 0 to 3
GLRT GLR NUMBER IN THE SMB-T
- Parameter symbolic name
- In the form <etu>-<glr>
- <etu> ETU rank in the SMB-T (1 ≤le etu ≤le 128)
- <glr> GLR rank in the ETU (0 ≤le glr ≤le 7)
GLRX GLR INTERNAL DESIGNATION IN THE NETWORK
- Parameter symbolic name
- Possible value : 0 to 2047
GMQ START OF THE GMQ PHASE FOR MMCDP
- PARAMETER VALUE
GOCE ENGAGEMENT CONTROLLED BY FOCE
- Value of parameter
GP PROTECTION GROUP NUMBER
- Symbolic name of parameter
- Possible values : 0 to 2
GPRF RIGHT TO A PRIORITY CUG
- Value of the CAT parameter
GS SERVICE MANAGEMENT ML GROUP
- Parameter value
GSi SERVICE MANAGEMENT ML i
- Parameter value (1 ≤ i ≤ 8)
GS ML GS
- TYML parameter value
GTA SERVICE CIRCUITS GROUP
- Parameter value
GTR START OF THE GTR PHASE FOR MMCDP
- PARAMETER VALUE
GTX START OF THE GTX PHASE FOR MMCDP
- PARAMETER VALUE

94 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

GWi GROUP OF ROUTING TOWARDS AN EXTERNAL SERVICE


- Parameter value (1 ≤le i ≤le 32)
GW ML GW
- TYML parameter value
GWAi ROUTING TOWARDS AN EXTERNAL SERVICE ML i LOGIC A
- Parameter value (1 ≤le i ≤le 32)
GWBi ROUTING TOWARDS AN EXTERNAL SERVICE ML i LOGIC B
- Parameter value (1 ≤le i ≤le 32)
GX CONNECTION HANDLING ML GROUP
- Parameter value
GX ML GX
- TYML parameter value
GX1 CONNECTION 1 HANDLING ML
- Parameter value
GX2 CONNECTION 2 HANDLING ML
- Parameter value
G811 Recommendation G811
-
G812L Recommendation G812 local
- Value of the parameter TIMQ
G812T Recommendation G812 transit
- value of the parameter TIMQ
H TIME SCHEDULE
- Value of parameter
HCEN CENTRAL TIME CHOSEN AS SYSTEM TIME
- Output symbolic name
- This is the median time of a sample of SM times.
HCH BUSY HOUR
- Symbolic name of parameter
HCH BUSY HOUR
- Symbolic name of parameter
HD TIME OF BEGINNING OF RATE TIMEBAND
- Symbolic parameter name
- In the form <hour>-<minute>
HDi GROUP OF HIGH BIT RATE INTERFACE CONNECTION MLs i
- Parameter value (1 ≤le i ≤le 32)

3BW 45305 AAAA RKAHA Ed. 07 95 / 236


SYMBOL DICTIONARY

HD ML HD
- TYML parameter value
HDAi HIGH BIT RATE INTERFACE CONNECTION ML i LOGIC A
- Parameter value (1 ≤le i ≤le 32)
HDBi HIGH BIT RATE INTERFACE CONNECTION ML i LOGIC B
- Parameter value (1 ≤le i ≤le 32)
HDEB OP OBSERVATION START TIME
- Symbolic name printed out
HED1 TIME FOR FIRST OUTPUT OF OBSERVATION RESULTS
- Symbolic name in output lists
HELP ON LINE HELP
- Symbolic parameter name
HEX HEXADECIMAL OUTPUT IN DUMP FORM
- Parameter value
HF TIME OF END OF RATE TIMEBAND
- Symbolic parameter name
- In the form <hour>-<minute>
HLCi VOICE SIGNAL ATTENUATION IN THE Rx DIRECTION
- Value of the parameter AECHO
- Possible values:
- i=1 no attenuation (default value)
- i=2 4 db of conditional attenuation
- i=3 6 db of conditional attenuation
- i=4 4 db of systematic attenuation
HOM COUNTERPART UNIT
- Possible value for the REG parameter
HOR EXEC. OF INSTRUCTION DELAYED UNTIL TIME SPECIFIED
- Symbolic name printed out
- On the form <HH>-<MN> where :
- <HH> varies from 0 to 23,
- <MN> varies from 0 to 59
HR TIME AT WHICH A TIME PERIOD COMES TO AN END
- Symbolic name of parameter
- Same semantics as HOR
HR EXECUTION HOUR (ELSE BUSY HOUR)
- Symbolic name of parameter

96 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Same semantics as HOR


HR WAKE-UP TIME
- Symbolic name of parameter
- On the form <HH> - <MN>
HRD OBSERVATION START TIME
- Symbolic name printed out
HRF OBSERVATION END TIME
- Symbolic name printed out
HRS SET TIME FOR OMC AND CHARGING UNIT CLOCK INIT.
- Symbolic name of parameter
- On the form HH-MN-SS
HRS SET TIME FOR OMC AND CHARGING UNIT CLOCK INIT.
- Symbolic name of parameter
- On the form HH-MN-SS
• 0 ≤ HH ≤ 23
• 0 ≤ MN ≤ 59
• 0 ≤ SS ≤ 59
HS EQUIPMENT OUT OF SERVICE
- Symbolic name printed out
HS CONTROL STATION NOT OPERATIONAL
- Parameter value
- Encompasses the statuses BLOM, BLOS, INDL, INDO, INIT, TEST
HS ETU OR ET OUT OF SERVICE
- Parameter setting
- STATUS or symbolic name in an output line
- The ET’s of the ETU are not handling traffic
HS OUT OF SERVICE
- Parameter value
- HS encompasses the statuses:
- INDL, BLOS, FEN, FLA, FLR, FLREi and FLRS.
H1 INTERVAL START-TIME TO BE PRINTED OUT
- Symbolic name of parameter
- On the form HH-MN
H2 INTERVAL END-TIME TO BE PRINTED OUT
- Symbolic name of parameter
- On the form HH-MN

3BW 45305 AAAA RKAHA Ed. 07 97 / 236


SYMBOL DICTIONARY

I ROUTING BARRED TO SUBSCRIBERS


- Value of parameter DIS
Ii TRUNK CIRCUITS
- Value of parameter
- 1 ≤ i ≤ 15
I IN SERVICE
- Value of parameter
I CHARACTERISTICS OF THE INTERMEDIATE LEVEL
- Parameter value
IAI NUMBER OF CALLS IN CAMP-ON CONDITION
- Value of CAT parameter
IAM ENTITLED TO MALICIOUS CALL IDENTIFICATION
- Value of parameter CAT
IAMT ACTION FORBIDDEN ON THE TEMPORARY MODE
- Value of the CAT parameter
IARG Integration parameter "n" for the command regulation alarms
- Symbolic parameter name
IATC TAPE IDENTIFICATION CODE
- Symbolic name of parameter
- On the form ’---------- ’
- 1 to 10 characters
IBR___ Battery Reversal Necessary
- Value of parameter TY for subscriber management
ICCM Call back on busy not allowed if the code is that for an outgoing call to a mobile network
- Value of the DIS parameter.
ICDCN CONVERSION TO TECHNICAL RELEASE PN+X OF COMMMAND (INCOMPATIBLE
TECHNI
- Parameter value
This mode allows the OCB reference archives to be converted to Pn+x. Updating of
these OCB archives is followed by initialization of OM function and movement of the
OCB system to technical release Pn+x. Stations operating under Pn (subsystem B) are
put into "BLOM".
This option is entered automatically by central defence when a change of technical
release is incompatible.
The initialization option for the future is set to NORON.
ICNE ICNE RACK-SHELF NUMBER
- Symbolic name of parameter
- Possible values :

98 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• 1 - 3 to 1 - 6
• 2 - 2 to 2 - 6
• 3 - 2 to 3 - 6
• 4 - 2 to 4 - 6
ICR INHIBITION OF SWITCHOVER TO REDUCED CONSUMPTION
- Value of parameter TY
ICT CHARGE METER INCREMENT
- Symbolic name printed out
ICT TYPE OF ALARM: SWITCHING - TRANSMISSION INTERFACE
- Parameter value
ICT NUMBER OF TAX (CHARGE) IMPUTED
- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value numeric on 3 bytes
ID IDENTIFIER OF MIC ON THE INTERFACE V5.2
- Symbolic name of parameter
- Parameter value : 0 to 255
ID V5.2 INTERFACE IDENTIFIER
- Parameter code name
- Any value from 0 to 16777215
ID ALARM CATEGORY: NON URGENT ACTION
- Parameter value
ID IDENTIFICATION OF AN ADAPTATOR
- Symbolic name printed out
- String of 10 characters (identification of the adaptor software)
IDAI ENTITLEMENT TO THE IDENTIFICATION OF THE CALLING PARTY IN PHASE IAI
- Value of parameter CAT
IDB ENTITLEMENT TO FIRST CALLED PARTY IDENTIFICATION
- CAT parameter value
- Symbolic name as output
IDC ENTITLEMENT TO ADVICE OF CHARGE (TOTAL COST)
- Value of parameter CAT
IDCOM EXCHANGE IDENTIFIRE
- Symbolic parameter name
- In the form <g>-<i>
- <g> Generation and use of the call reference ( 0 ≤ g ≤ 1 )

3BW 45305 AAAA RKAHA Ed. 07 99 / 236


SYMBOL DICTIONARY

- <i> Exchange identifire ( 0 ≤ i ≤ 16383 )


IDCP CALLING LINE IDENTITY
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• dialling on 1 to 16 digits
IDDR GIVING THE IDENTITY OF THE CALLING PARTY
- Symbolic name of parameter
- Possible value YES : IDR compulsory
- NO : IDR not compulsory (supplied if available)
- PREF: IDR is supplied to the server if possible
IDENT IDENTIFICATION OF VOLUME OWNER
- Symbolic name of parameter
- 14 characters as a maximum
- In the label starting the volume (VOL 1), when premarking
- a magtape (implicitely : CIT 128)
IDENT IDENTIFIER
- symbolic name of parameter
- Possible values :
- The files CTILAS, CTIPRM, TRVLAS, TRVPRM, CTIFIL.
- The associated logic disks DLCONF and DLFICH.
IDFIC NAME OF MAGTAPE PHYSICAL FILE
- Symbolic name of parameter
- String including 1 to 17 characters
- between quotes
IDFIE NAME OF INPUT FILE
- Symbolic name of parameter
- String including up to 17 alphanumeric characters
IDFIS NAME OF OUTPUT FILE
- Symbolic name of parameter
- String including up to 17 alphanumeric characters
IDI IDENTIFICATION IMPOSSIBLE
- Value of parameter CTA
IDJDF IDENTIFICATION OF THE SET OF FILES
- Symbolic name of parameter
- 6 alphanumerics characters as a maximum

100 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

IDLS MODIFICATION OF LS IDENTIFIER


- Value for TYMO parameter
IDN CALL FORWARDING MARK ACTIVATING THE TRANSMISSION OF A MESSAGE TO THE
OMC
- Symbolic output name
- The value is output in the form of <INDEX>-<BIT>,
- INDEX: range of values: 0 to 15
- BIT : range of values: 0 and 1
IDRV IDENTITY OF FORWARDER
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• dialling in no more than 16 digits preceded by number type
IDRXA RETRANSMISSION OF IDENTITIES DOWNSTREAM WITH DISCLOSURE INDICATOR SET
TO "PROHIBITED"
- Value of the DIS parameter
IDS SERVICE INDEX IN-CS1
- Symbolic name of parameter
- Possible values : From 1 to 255
IDSES NAME OF SESSION IDENTIFIER
- Parameter symbolic name
IDSV SERVICE IDENTIFIER
- Symbolic name of parameter
- Possible value from 0 to 65535
IDT IMMEDIATE METERING INDICATION
- Value of parameter CAT
IDT IMMEDIATE METERING INDICATION
- Value of parameter CTA
IDUS CALLING PARTY DESIGNATION NUMBER
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• dialling from 1 to 16 digits
IEC INFORMATION ON FAILURE TO BE SENT
- Symbolic name of parameter
- Possible value :
• ECH

3BW 45305 AAAA RKAHA Ed. 07 101 / 236


SYMBOL DICTIONARY

• ENC
IECT Signalling route not permitted to explicit call transfer ECT
- Value of the DIS parameter
IECX Signalling route not permitted to explicit call transfer ECT unless subscriber’s CAT=ECTI
- Value of the DIS parameter
IELM SOFTWARE/HARDWARE EDITION NUMBER
- Parameter symbolic name:
- possible values: 0 ≤ IELM ≤ 255
IELP LINE AND TELEPHONE SET TEST ILLEGAL
- Value of parameter TY
IET THIRD PARTY CUT-IN
- Value of parameter CAT (CENTREX)
IIB BATTERY REVERSAL ILLEGAL
- Value of parameter TY
IID AREA CODE WITH IDT OPTION ON A PER CALL BASIS
- DIS parameter value, ANALYSIS MANAGEMENT.
ILS NAME OF LS IDENTIFIER
- Symbolic name of parameter
ILS NAME OF LS IDENTIFIER
- Symbolic name of parameter
IM RECEPTION OF CHARGES PULSES
- Symbolic name at output
IM RECEPTION OF CHARGES PULSES
- Value of parameter MDTX
IMi DIGITS INSERTED WITH RANK i
- Value of parameter DIS
- 1 ≤ i ≤ 15
IM ALARM CATEGORY: URGENT ACTION
- Parameter value
IMPO Operated imported routing code
- Value of DIS parameter
IMV INITIALIZATION OF VALIDATION MODE
- Symbolic name of parameter
- Possible values :
• YES : case of FTIN file with 128 articles,
• NO : case of FTIN file with 32 articles.

102 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

IN INTERROGATION OF MMCDP PARAMETERIZATION ARCHIVE FILES


- PARAMETER VALUE
INA SIGNALING POINT INACCESSIBLE GLOBALLY
- Value of parameter ACCE
INAC SIGNALLING LINK INACCESSIBLE
- Value of parameter ETCS
INC FIRE ALARM
- Symbolic name printed out
INC TYPE OF ALARM: FIRE
- Parameter value
IND INDEX OR NETWORK NUMBER
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal number in 3 digits
IND ROUTING CODE
- Symbolic name of parameter
- Number with 1 to 8 digits (analysis)
- with 2 to 8 digits (analysis) (France : 2 to 5)
- with 1 to 24 (routing)
- values given to this parameter as a < b must have the same number of digits on each
side of sign <.
IND PCM UNAVAILABILITY STATUS
- Value of parameter ETAT
IND PCM UNAVAILABILITY STATUS
- Value of parameter ETAT
INDA OLD ROUTING CODE
- Symbolic name of parameter
INDE CODE OF CALL TO REMOTE AUTOMATIC TRANSPONDER
- Symbolic name of parameter
- Number including 2 to 8 figures
INDE PART TWO OF THE CALLED PARTY GLOBAL ADDRESS
- Symbolic name of address in code form (20 digits)
- -numbers from 0 to 9
INDEX GFU NUMBER FOR A SUBSCRIBER
- Symbolic name of parameter
- Possible values : 1 to 4

3BW 45305 AAAA RKAHA Ed. 07 103 / 236


SYMBOL DICTIONARY

INDI UNAVAILABILITY DURATION IN SECONDS


- Symbolic name in output lists
INDL UNAVAILABLE IDLE EQUIPMENT
- Value of parameter
INDL CONTROL STATION UNAVAILABLE FREE
- Parameter value
- Status set by MMC or temporarily by the system.
- The SM does not contribute to the traffic.
INDL SOFTWARE MACHINE UNAVAILABLE FREE
- Parameter value
- The host SM has been set to INDL by MMC or by the system.
- The ML does not contribute to the traffic.
INDL MULTIPLEX RING UNAVAILABLE
- Parameter value
- The ring has been withdrawn from service by the operator; it is no longer processing
traffic.
INDL UNAVAILABLE
- Parameter value
INDL ETU OR ET UNVAILABLE FREE
- Parameter setting
- STATUS or symbolic name in an output line
- The ET’s of the ETU are no longer handling traffic
INDLS UNAVAILABLE EQUIPMENT SEIZED FOR DEDICATED LINK
- Symbolic name printed out
INDM ATME TEST CODE
- Parameter value
INDN NATIONAL ROUTING CODE
- Symbolic name of parameter
- Number from 1 to 4 digits
INDO UNAVAILABLE BUSY EQUIPMENT
- Symbolic name printed out
INDO INDICATIVE
- Symbolic name of parameter
- INDO = <TRA> - <indicative>
- = <TRAD> - 1 to 15
- = <indicative> = indicative
INDO CONTROL STATION UNAVAILABLE BUSY

104 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Parameter value
- The SM has been set to INDL by MMC or by the system; The SM concludes operations
in progress.
INDO SOFTWARE MACHINE UNAVAILABLE BUSY
- Parameter value
- The host SM has been set to INDL by MMC or by the system; The ML concludes op-
erations in progress.
INDO ETU OR ET UNVAILABLE BUSY
- STATUS or symbolic name in an output line
- The ET’s of the ETU are handling residual traffic
INDR REGIONAL CODE
- Symbolic name of parameter
- Number including 1 to 8 figures
INDR PART TWO OF THE CALLING PARTY GLOBAL ADDRESS
- Symbolic name of parameter in code form (20 digits)
- -numbers from 0 to 9
INDS ADDITIONAL ROUTING CODE ASSOCIATED WITH I/C GROUP CIRC.
- Symbolic name of parameter
- Number including 1 to 10 figures
INDT IDENTIFIER OF CHARGED CIRCUIT GROUP
- Symbolic name of parameter
- One to 10-digit number
INDTX CHARGING INDICATOR
- symbolic name of parameter
INDXP PREFERENTIAL GFU NUMBER FOR A SUBSCRIBER
- Symbolic name of parameter
- Possible values : 1 to 4
INEn NUMBER OF MESSAGES SENT
- Symbolic name in output lists
- n : service indicator
INEF REASON FOR FAILURE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
INEF OBSERVATION OF CAUSES OF NON-COMPLETION
- Value of parameter TYOBS

3BW 45305 AAAA RKAHA Ed. 07 105 / 236


SYMBOL DICTIONARY

INEX INEXISTANT
- Symbolic name printed out
- The element searched for or interrogated does not exist
INEX SERVICE NOT USED
- Parameter value
INF INFORMATION ANNOUNCEMENT
- Value of parameter DIS
INHD DISTANT INHIBITION - COMPONENT OF INHIBITION
- Symbolic name output
INHD SIGNALLING LINK DISABLED BY REMOTE SP
- Symbolic name output
- Setting of ETCS parameter.
INHEC ACTIVATION/INHIBITION OF THE CENTRE CLIPPER
- Parameter symbolic name
- Possible values:
- YES : INHIBIT
- NO : ACTIVATE (default value)
INHGB ACTIVATION/INHIBITION OF WAITING MUSIC GENERATION
- Parameter symbolic name
- Possible values:
- YES : INHIBIT
- NO : ACTIVATE (default value)
INHL SIGNALLING LINK INHIBITED LOCALLY
- Value of parameter ETCS
INHT TOTAL INHIBITION - COMPONENT OF INHIBITION
- Symbolic name output
INHT SIGNALLING LINK DISABLED AT BOTH ENDS
- Symbolic name output
- Setting of ETCS parameter.
INI INITIALIZATION OF A SUB-DIAGRAM
- Symbolic name of parameter
- Value : SCH, on 6 characters
INI INITIALIZATION VALUE
- Symbolic name of parameter.
- Hexadecimal number limited to 4 screen characters once translated into hexadecimal.
- Lower limit INI=0 or ini=H’0’

106 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Upper limit INI=65535 or ini=H’FFFF’


INIGi SYSTEM IN GENERAL INITIALIZATION STEP i
- Parameter value (0 ≤le i ≤le 3)
- i is the step number
- Step 0 : Initialization of OM function
- Step 1: Initialization of control ML support SMs
- Step 2: Initialization of network ML support SMs,
- initialization of the switching network,
- initialization of No. 7, auxiliary equipment and
- terminations ML support SMs
- Step 3: Initialization of time, data link creation,
- initialization of Nº 7 functions
- The system is in a situation of total failure
INION GENERAL SYSTEM INITIALIZATION
- Parameter value
This mode allows the initialization of OM function along with initialization of all sta-
tions of the OCB starting from the OM.
After station initialization has been executed, operation functions are available.
The initialization option for the future is set to NORON.
INIT EQUIPMENT IN INITIALIZATION
- Symbolic name printed out
INIT CONTROL STATION BEING INITIALIZED
- Parameter value
- The SM has been set to ES or INDL by MMC or by the system.
INIT SOFTWARE MACHINE BEING INITIALIZED
- Parameter value
- The host SM has been set to ES or INDL by MMC or by the system.
INIT ETU BEING INITIALIZED
- STATUS or symbolic name in an output line
- The ETU is not handling traffic
INIT INITIALIZATION
- Parameter value.
INITG ALARM RELATING TO A GENERAL SYSTEM INITIALISATION
- Parameter value
INO TYPE OF ALARM: FLOOD
- Parameter value
INRn NUMBER OF MESSAGES RECEIVED

3BW 45305 AAAA RKAHA Ed. 07 107 / 236


SYMBOL DICTIONARY

- Symbolic name in output lists


- n : service indicator
INS INSERTION OF SUBSCRIBER OR CIRCUIT GROUP CODE
- Parameter value
- Parameter : DIS
INS RE-INSERTION OF A RING ADAPTER
- Parameter value
- Request for re-insertion of an adapter.
INSPn PRELIMINARY ANALYSIS DIGIT INCORPORATION
- CAT or CTA parameter value
- INSP1 : incorporation before preliminary analysis
- INSP2 : incorporation after preliminary analysis
INT ENTITLEMENT TO CALL INTERCEPTION
- Value of parameter CAT
INTn NO.OF MESSAGES RECEIVED AND TRANSFERRED
- Symbolic name output
- n : service indicator
INT PROHIBITION OF CIRACT AND CIRDEM
- Value of parameter AEAC
INTB T INTERFACE ON BASIC ACCESS
- Value of the TY parameter
INV SERVICES INVOKED
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
INX INITIAL SELECTION DIGITS
- DIS parameter value
INZ INSERTION OF A ZONE CODE
- Parameter value
- Parameter : DIS
IOP INDEX OF COUNTERS GROUP ON THE OPERATOR INTERFACE
- Symbolic name output.
IPROC ROC (completion of calls to busy subscriber) service activation prohibited
- Value of parameter DIS
IR NETWORK INTERFACE

108 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Parameter code
- List of two possible entries
- Possible values from 0 to 3
- For a network, according to the point code format (14, 24 or 14/24 bits), IR (network
interface) should indicate either the network interface for the 14 bit format, or the
network interface for the 24 bit format, or a list of two entries, the first for the 14 bit
format, the second for the 24 bit format.
IRn RAPID PRINTED
- Value of parameter
IRM MULTIPLEX CONNECTION INTERFACE
- Value of parameter
IROC INHIBITION OF AUTOMATIC CALL-BACK ON BUSY CALLED PARTY IN INCOMING
- DIS parameter value, (analysis)
IROC PROHIBITION OF AUTOMATIC CALL-BACK ON BUSY CALLED PARTY INCOMING
- Value of parameter CAT
IRR NO. OF IRRATIONAL MESSAGES RECEIVED
- Symbolic name output
IRS SATELLITE CONNECTION INTERFACE
- Value of parameter
- The end involved is the local end
IRV ROUTING ILLEGAL FOR TEMPORARY TRANSFER
- Value of parameter DIS
IRX ROUTING NOT ALLOWED FOR DIVERSION UNLESS SUBSCRIBER HAS THE CATEGORY
RIN
- DIS parameter value
ISA CALLING LINE IDENTITY RESTRICTION NOT ALLOWED FOR A SINGLE CALL
- Value of the CAT parameter
ISDNS DIGITAL
- Value of parameter
ISF STATISTIC INDICATOR OF ERRORS
- Symbolic name printed out
ISO COUNTRY’S ISO CODE
- Symbolic name of parameter
- Possible values
• 2-character string
• e.g. ’MY’
IST FREE OF CHARGE COMMAND ILLEGAL
- Value of parameter DIS

3BW 45305 AAAA RKAHA Ed. 07 109 / 236


SYMBOL DICTIONARY

ISTA TO PREVENT SELECTION OF A CARRIER ON A PER-CALL BASIS


- Value of parameter CAT for subscriber management.
- Value of parameter DIS for pre-analysis management.
ITV TIME SLOTS ON A V5.1 PCM
- Symbolic name of parameter
- Sous la forme:
• ITi-1 + ITi-2 for ISDN CPEs
• ITi-1 for the analogue subscribers
- with 1 ≤ ITi ≤ 31 but different from 16
I2F 2-WIRE EQUIPMENT DISCRIMINATED WITH IB
- Symbolic name output
I2F16 TU WITH 16 DISCRIMINATED (IB) 2-WIRE EQUIPMENTS
- Value of parameter
I3F 3-WIRE EQUIPMENT DISCRIMINATED WITH IB
- Symbolic name output
J REJEX TEST INDICATOR
- Value of parameter TYP
JA I/C JUNCTION
- Symbolic name printed out
JD O/G JUNCTION
- Symbolic name printed out
JDB STATUS REPORT PRINTOUT
- Value of parameter
JM B/W JUNCTION
- Symbolic name printed out
K TEST OF A KEYBOARD SET
- Value of parameter
- The operator has to ask the subscriber
- to push all the buttons of his keyboard
- before typing this command
KA CALLER CATEGORY
- Symbolic name for output
- Output field read from the magnetic tape of detailed billing type
- Possible values:
• decimal number between 0 and 15
CLE NUMBER OF EXTERNAL SERVICE KEYS

110 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name on output


- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal values from 1 to 4 bytes
KEY KEY ACCES TO FILE ITEM
- Value of parameter
KEY NAME OF OM FILE RECORD
- Symbolic parameter name
- Name from 1 to 6 characters
KLA KEYBOARD SET (OR DIAL + KEYBOARD)
- Value of TY parameter
L NUMBER OF LINE FEATURE
- Symbolic name of parameter
L COMPLETE TESTS OF A LINE
- Value of parameter
- Interlinking from L1 to L8 or L12 depending on the type of robot
Li LINE FEATURE MEASUREMENT
- Value of parameter
Ln MEASUREMENT OF A LINE CHARACTERISTIC
- Value of parameter
- 1 ≤ n ≤ 12
- L1 MEASUREMENT OF AN ALTERNATING CURRENT VOLTAGE BETWEEN WIRE
- A AND THE EARTH
- L2 MEASUREMENT OF A ALTERNATING CURRENT VOLTAGE BETWEEN WIRE B
- AND THE EARTH
- L3 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE A AND
- THE EARTH
- L4 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE B AND
- THE EARTH
- L5 MEASUREMENT OF AN ISOLATION BETWEEN WIRE A AND THE EARTH
- L6 MEASUREMENT OF AN ISOLATION BETWEEN WIRE B AND THE EARTH
- L7 MEASUREMENT OF AN ISOLATION BETWEEN WIRES A AND B
- L8 MEASUREMENT OF A CAPACITANCE BETWEEN WIRES A AND B
- L9 MEASUREMENT OF AN ALTERNATING CURRENT VOLTAGE BETWEEN WIRE
- A AND WIRE B
- L10 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE A AND

3BW 45305 AAAA RKAHA Ed. 07 111 / 236


SYMBOL DICTIONARY

- WIRE B
- L11 MEASUREMENT OF A CAPACITANCE BETWEEN WIRE A AND THE EARTH
- L12 MEASUREMENT OF A CAPACITANCE BETWEEN WIRE B AND THE EARTH
L GLR LA CHARACTERISTICS
- Parameter value
LA RANK OF LA LINK IN A GROUP
- Output symbolic name
- Possible values : 0 to 7
LAB LOGICAL DISK LABEL
- Symbolic parameter name
LAB is used to designate the physical label of a logical disk belonging to an OM
secondary memory.
- The label has an add component and a substract component, separated by an "/"
character. The add component is used to create a logical disk that does not yet exist
in the list of logical disks for the MSO and the subtract component is used to delete
a logical disk from the list of logical disks for the MSO. The two components can be
used together or separately.
- Possible values:
- SYST0025, SYST0024/SYST0022, etc.
LAB LOGICAL DISK LABEL
- Symbolic name of parameter
- 8 caracters exactly
- Define the logical disk label on which the file creation must be done
LABO__ Listing of inconsistencies related to subscribers.
-
LAI HOT LINE
- Value of parameter CAT
LAS MODIFICATION PARAMETER OF FILE TRVLAS
- Symbolic name of parameter
- List of up to 4 explicit strings. Each string describes a modifiable parameter of TRVLAS
among :
• TY : maximum number of teletype terminals
• CV : maximum number of VDU type terminals
• IR : maximum number of printing terminals
• CDC : maximum number of switching centers
LAT ROMAN TYPE CHARACTER
- Value of parameter CAR in commands LASCR, LASMO
LAT LINE WITH DELAYED ROUTING

112 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter CAT


LATF LINE WITH PRESET DELAYED ROUTING
- value of parameter CAT
LAW TRAFFIC ALLOCATION LAW
- Symbolic name of parameter
- Possible values : 1 to 31
LOI LAW FOR SEARCHING AN AVAILABLE CIRCUIT IN C.S.A. GROUP
- Symbolic name of parameter
- Value from 1 to 3
LC READING OF OMC CHANNEL STATUS
- Value of parameter
LCLn LINE CURRENT LIMITATION
- Value of parameter TY
- Possible values : 1 < n < 3
LCT READOUT
- Value of parameter
LEV1 POWER PRESENT ON THE CHANNEL IN Tx
- Symbolic name of parameter output
LEV2 POWER PRESENT ON THE CHANNEL IN Rx
- Symbolic name of parameter output
LFL FAULTY LINE
- Value of parameter TY
LFN FILE LOGIC NAME
- Symbolic name of parameter
- 4 characters as a maximum
LFNB NAME OF GENERAL PURPOSE LFN
- Symbolic name of parameter
LFND DESTINATION FILE LOGIC NAME
- Symbolic name of parameter.
- 4 characters maxi.
LFNE NAME OF LFN EXTERNAL SUPPORT
- Symbolic name of parametre.
- The LFNE parameter is exclusif to the BM and MNT parameters.
- If the LFNE parameter is present, the loading is imposed.
LFNS SOURCE FILE LOGIC NAME
- Symbolic name of parameter.

3BW 45305 AAAA RKAHA Ed. 07 113 / 236


SYMBOL DICTIONARY

- 4 characters maxi.
LG GEOGRAPHIC LOCATION
- Symbolic name of parameter
- Geographic locationfor CNE
LGA LENGTH IN WORDS OF AN ARCHIVE FILE ITEM
- Symbolic parameter name
- Number from 0 to 32767
LGAR EFFECTIVE SIZE OF AN ARCHIVE
- Symbolic parameter name
- Value expressed in Kbytes for each archive.
LGE FILE LENGTH IN BYTES
- Symbolic name of parameter
LGE LENGTH IN WORDS OF AN ARCHIVE FILE RECORD
- Symbolic parameter name
- Number from 0 to 32767
LGR TAPE ANALYSIS RELATED TO LENGTH OF BLOCKS
- Value of parameter
LIB HEADING OR WORDING
- Symbolic name of parameter.
- Command heading (from 1 to 36 characters).
- Alarm wording (from 1 to 33 characters).
LIB RELEASE
- Symbolic name of parameter
- Possible values: YES, NO (NO: implicit)
LIBR FREE EQUIPMENT
- Value of parameter
LIC LINK IDENTIFICATION CODE INSIDE THE CRCT GRP
- Symbolic name of parameter
- Possible value : from 1 to 1000
LIGNE OPTIONAL LINE FOR PROGRAM LOADING
- Symbolic name of parameter
LIST NO. OF PRE-RECORDED OBSERVATION LIST
- Symbolic name of parameter
- The parameter takes value
- 1, 2 or 3 except for the complementary
- circuit group observation and O/G traffic

114 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- observation (1 to 20)
- LIST=0 : if halt : halt of the observation with no result
- : if interrogation: interrogation of list under current observation.
- Where the parameter is optional,
- the default value is 1. (except for the destination’s observation)
LIST OPTION FOR PRINTOUT PROGRAM MODULE
- Symbolic name of parameter
LIST LISTING
- Parameter value.
LIST LISTING
- Parameter value.
- possible values : SISA, PILE, ZONEZ, DATA, CODE, SPSW.
- In the last 3 cases, values can be assigned to parameters "DEB" and "NSEC"
- Some output values are mutually exclusive : PILE, ZONEZ, DATA, CODE and SPSW.
LISTE LIST OF NON-COMPLETION CAUSES
- Parameter symbolic name
- Possible values are : DCE - DCS
LLP LLP PRESENT ON THE ACCESS
- Value of parameter MAR
LNP NON PREFERENTIAL LINE
- Value of parameter
LNU INTERNAL DIALLING LENGTH
- Symbolic name of parameter
LO READING OF OC STATUS
- Value of parameter
LOC LOCAL ROUTING
- Value of parameter
LOC CHANGEOVER TO LOCAL MODE.
- Parameter value
- In experimental phase, this changeover causes the current session to be interrumpted.
- In normal phase, this changeover is prohibited if a session is in progress.
LOCAL TYPE OF ROOM FOR A REMOTE SITE
- Symbolic name of parameter
- 3 for a satellite exchange (URAD),
- 4 for a geographic location (CNE).
LOCK LOCKOUT OF PROTECTION

3BW 45305 AAAA RKAHA Ed. 07 115 / 236


SYMBOL DICTIONARY

- Value of parameter REQ


LAW1 SEARCH LAW IN SEARCH SUBGROUP 1
- Symbolic name of parameter
LAW2 SEARCH LAW IN SEARCH SUBGROUP 2
- Symbolic name of parameter
LR UR NETWORK LINE (LRE+LRS)
- Symbolic name printed out
LRE CX INPUT LINE
- Symbolic name printed out
LRS CX OUTPUT LINE
- Symbolic name printed out
LRX SWITCH NETWORK LINE
- Symbolic name printed out
LSD SIGNALLING DATA LINK
- Symbolic name of parameter
- Possible value : from 1 to 255
LSP LS PRESENT ON THE ACCESS
- Value of parameter MAR
LSS ESSENTIAL LINE
- Value of parameter TY
LST TRANSMIT-ONLY LINE
- Symbolic name output
LST CHARGE FREE LINE (A CATEGORY OF THE CALLED PARTY)
- Value of parameter CAT
LST OPTION FOR PRINTOUT TRANSFER ON TO A TERMINAL
- Symbolic name printed out
L1 MEASUREMENT OF AN ALTERNATING CURRENT VOLTAGE BETWEEN WIRE A AND THE
EARTH
- Parameter value
L1Ej SIGNALLING CODE : LINE CODE 1
- Value of parameter SG
- register code j from 1 to 31
L2 MEASUREMENT OF A ALTERNATING CURRENT VOLTAGE BETWEEN WIRE B AND THE
EARTH
- Parameter value
L2Ej SIGNALLING CODE : LINE CODE 2
- Value of parameter SG

116 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- register code j from 1 to 31


L3 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE A AND THE EARTH
- Parameter value
L3Ej SIGNALLING CODE : LINE CODE 3
- Value of parameter SG
- register code j from 1 to 31
L4 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE B AND THE EARTH
- Parameter value
L4Ej SIGNALLING CODE : LINE CODE 4
- Value of parameter SG
- register code j from 1 to 31
L5 MEASUREMENT OF AN ISOLATION BETWEEN WIRE A AND THE EARTH
- Parameter value
L5Ej SIGNALLING CODE : LINE CODE 5
- Value of parameter SG
- register code j from 1 to 31
L6 MEASUREMENT OF AN ISOLATION BETWEEN WIRE B AND THE EARTH
- Parameter value
L6Ej SIGNALLING CODE : LINE CODE 6
- Value of parameter SG
- register code j from 1 to 31
L7 MEASUREMENT OF AN ISOLATION BETWEEN WIRES A AND B
- Parameter value
L7Ej SIGNALLING CODE : LINE CODE 7
- Value of parameter SG
- register code j from 1 to 31
L8 MEASUREMENT OF A CAPACITANCE BETWEEN WIRES A AND B
- Parameter value
L8Ej SIGNALLING CODE : LINE CODE 8
- Value of parameter SG
- register code j from 1 to 31
L9 MEASUREMENT OF AN ALTERNATING CURRENT VOLTAGE BETWEEN WIRE A AND
WIRE B
- Parameter value
L9Ej SIGNALLING CODE : LINE CODE 9
- Value of parameter SG
- register code j from 1 to 31

3BW 45305 AAAA RKAHA Ed. 07 117 / 236


SYMBOL DICTIONARY

L10 MEASUREMENT OF A DIRECT CURRENT VOLTAGE BETWEEN WIRE A AND WIRE B


- Parameter value
L10Ej SIGNALLING CODE : LINE CODE 10
- Value of parameter SG
- register code j from 1 to 31
L11 MEASUREMENT OF A CAPACITANCE BETWEEN WIRE A AND THE EARTH
- Parameter value
L11Ej SIGNALLING CODE : LINE CODE 11
- Value of parameter SG
- register code j from 1 to 31
L8 MEASUREMENT OF A CAPACITANCE BETWEEN WIRE B AND THE EARTH
- Parameter value
L12Ej SIGNALLING CODE : LINE CODE 12
- Value of parameter SG
- register code j from 1 to 31
L13Ej SIGNALLING CODE : LINE CODE 13
- Value of parameter SG
- register code j from 1 to 31
L14Ej SIGNALLING CODE : LINE CODE 14
- Value of parameter SG
- register code j from 1 to 31
L15Ej SIGNALLING CODE : LINE CODE 15
- Value of parameter SG
- register code j from 1 to 31
M B/W CIRCUIT GROUP
- Value of parameter
M TYPE OF SUBSCRIBER OBSERVATION
- Symbolic name printed out
- Printed out il a subscriber is observed in caller and called condition
- (TRAF = A + D)
MA SYMBOL OF ACCESS METHOD
- Symbolic name of parameter.
MAI TYPE OF MESHES TO BE OBSERVED
- Symbolic name of parameter
- Takes values
• SE : Input sections

118 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• MS : Output meshes ( value " by default " )


MAIN MAINTENANCE UNIT NUMBER
- Parameter value
- Possible value : from 1 to 15
MAINT EQUIPMENT IN MAINTENANCE
- Symbolic name printed out
MAJ MAGNETIC TAPE WITH OR WITHOUT OPTION UPDATING
- Symbolic name of parameter
- Possible values :
• MAJ = YES extension of file already present on the tape.
• Writes the data after the last block already writen
• MAJ = NO (implicit option) no request for updating
MAL "HOLD ALARM" ANNOUNCEMENT
- Symbolic name printed out
MANON OM INITIALIZATION IN MANUAL MODE
- Parameter value
This mode allows OM function to be initialized and all stations of the OCB to be put
into "BLOM". All operation functions are available except periodic functions. Initial-
ization of the OCB is performed from the operating terminals (MMC ESMMO) under
operator control.
Following manual initialization of the stations, the operator should re-initialize OM
function in NORON so that all OM functions will be operational.
This initialization option is saved for future use.
MAR MARKS INDICATING STATUS OR OPERATION CONDITIONS OF THE LINE
- Symbolic name of parameter
- The possible values are the following symbols: ABS, ABSO, ADM, ADN, ARC, ARFN,
ARFO, ARFT, ARN, ARO, ART, ARV, ASD, ATT, EHS, ODDA, ODDD, OLGX, OLDX,
ODGD, ODGA, LLP, LSP, NNU, RNIS, SECR, SIO, STX
MAR MARKS INDICATING A CIRCUIT OR CIRCUIT GROUP STATUS
- Symbolic name of parameter
- Possible values : OBS, OFA, OFD, COB, FDS, OCA, OCD, ODT, STX.
MAR MARKS ASSOCIATED WITH ROUTING
- Symbolic name of parameter
- CAL ACH determined by calendar (type 10)
- OBS ACH observed
- AND ACH associated with ND
- LOC multiple ACH including a local ACH
MAR OBSERVATION MARK FOR ANALYSIS OR PREANALYSIS

3BW 45305 AAAA RKAHA Ed. 07 119 / 236


SYMBOL DICTIONARY

- Symbolic name of parameter


- Possible values : OBS (for ANALYSIS) - OBP (for PREANALYSIS)
MARJ__ mark for anonymous call rejection
-
MAS SET OF THE MAIN CONTROL STATION ACCESS MULTIPLEXES
- Parameter value
MASi MAIN CONTROL STATION ACCESS MULTIPLEX i
- Parameter value (1 ≤le i ≤le 4)
MASAi MAIN CONTROL STATION ACCESS MULTIPLEX i RING A
- Parameter value (1 ≤le i ≤le 4)
MASBi MAIN CONTROL STATION ACCESS MULTIPLEX i RING B
- Parameter value (1 ≤le i ≤le 4)
MAS1 MAS1 MULTIPLEX TRAFFIC
- Value of parameter ENT
MAS1 MAS1 MULTIPLEX
- Value of parameter ENT
MAS2 MAS2 MULTIPLEX TRAFFIC
- Value of parameter ENT
MAS2 MAS2 MULTIPLEX
- Value of parameter ENT
MAS3 MAS3 MULTIPLEX TRAFFIC
- Value of parameter ENT
MAS3 MAS3 MULTIPLEX
- Value of parameter ENT
MAS4 MAS4 MULTIPLEX TRAFFIC
- Value of parameter ENT
MAS4 MAS4 MULTIPLEX
- Value of parameter ENT
MAT CAMP-ON BUSY
- Value of parameter MAR
MAX MAXIMUN VALUE OF MEASUREMENT OF A LINE CHARACT.
- Symbolic name printed out
MCB LOCAVAR XMCB
- Symbolic name of parameter
MCT TARIFF CHANGE MODE
- Symbolic name of parameter
MDTX CHARGING METHOD

120 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- Refer to operating data
MDXP OPERATING MODE
- Symbolic name of parameter
- The parameter can take the values :
• BM : Magtape operating mode
• Q3 : Session operating mode
MENV NUMBER OF PABX TO PABX MESSAGES SENT
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal number in maximum 3 digits
MERE NUMBER OF PABX TO PABX MESSAGES RECEIVED
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal number in maximum 3 digits
MES TELEX MESSAGE BETWEEN TERMINALS
- Symbolic name of parameter
- The length of the message should be sized so as to have a parameters line including
240 characters a maximum
MES MESSAGE TO SEND TO THE EXCHANGE
- Symbolic name of parameter
MES1 NUMBER OF ACCESS FIELDS WITH AI ACCESS TYPE ACCESS
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
MES2 NUMBER OF XU ACCESS FIELDS WITH XU TYPE ACCESS
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
MIC HARDWARE ADDRESS OF PCM LINK AT CDC END (SMBT)
- Symbolic name of parameter
- The value is specified in the form : <RGTU No>-<RGET No>-<RGMIC No>
- The RGTU number is comprised between 1 and 128

3BW 45305 AAAA RKAHA Ed. 07 121 / 236


SYMBOL DICTIONARY

- The RGET number is comprised between 1 and 16


- The RGMIC number is comprised between 1 and 64
MIC LINK PCM
- Value of parameter ENS
MIC1G FIRST-GENERATION PCM
- Value given to the symbol : 1
MIC2G SECOND-GENERATION PCM
- Value given to the symbol : 0
MIL THOUSAND LOCAL SUDSCRIBER
- Symbolic name of parameter
- Thousands printout : 0 to 9 and A, J, S, C
MIN MINIMUN VALUE OF MEASUREMENT OF A LINE CHARACT.
- Symbolic name printed out
MIS MIS1 MULTIPLEX TRAFFIC
- Value of parameter ENT
MIS INTER-STATION MULTIPLEX
- Parameter value
MIS MIS MULTIPLEX
- Value of parameter ENT
MISA INTER-STATION MULTIPLEX RING A
- Parameter value
MISB INTER-STATION MULTIPLEX RING B
- Parameter value
MIX NON DEDICATED LINE (NON-DESIGN. LINE’S DFLT VALUE)
- Value of TY parameter
MLA AVERAGE NO. OF ACTIVE LLP’S
- symbolic name at output
MM MASSE MEMORY
- Value of parameter DV
- possibles values : 1 or 2
MNT ASSIGNATION W/OR WITHOUT AUTOMATIC MOUNTING
- Symbolic name of parameter
- Possible values : Yes or No
• MNT = YES : following command assignation, the mounting
• is automatically assigned and requested.
• MNT = NO : no request for automatic mounting

122 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• following assignation.
- Implicitely MNT = N, except for a permanent file
- which has been closed due to a lack of standby volume.
MO MODIFICATION OF MMCDP PARAMETERIZATION ARCHIVE FILES
- PARAMETER VALUE
MOAB CAN BE MODIFIED BY THE SUBSCRIBERS
- Value of parameter
MOB SELECTED CALL COMPLETION CODE
- DIS parameter value
MOD DATA MODIFICATION ENTITLEMENT (DEFAULT VALUE)
- Value of parameter TY
MOD NAME OF LOCAVAR MODULE TO BE EXECUTED
- Symbolic name of parameter
- 8 characters maximum
MOD CALL SUPERVISION MODE
- Symbolic name of parameter
- Possible values: EA, RE, AC, FE
MOD TRANSMISSION MODE
- Symbolic name of parameter
- Possible values :
• MOD = CAR : character mode (default)
• MOD = XON : mode XON/XOFF
MOD OPERATION MODE (VN5 OR VN6)
- Symbolic name of parameter
- Possible values : A(VN5) or N(VN6)
MODE CHARGING MODE TO BE APPLIED
- Symbolic name of parameter
- The value given to the parameter must be included between 0 and 3
• MODE 0 = periodic charge
• MODE 1 = simple charge (not charged on duration)
• MODE 2 = charge per unit
• MODE 3 = charge per unit (1st time-period different from the following ones)
MODE OPERATING MODE OF DIRECTED CALLS
- Symbolic name printed out
- "UR" or "PERCENT" mode
MODE HALT MODE

3BW 45305 AAAA RKAHA Ed. 07 123 / 236


SYMBOL DICTIONARY

- Symbolic name printed out


- Possible values :
- Mode = 1 : halt by system
- Mode = 2 : halt by operator
MODE ARCHIVE OR FILE COPYING MODE
- Symbolic parameter name
- Possible values:
• DUPL Duplication of an archive or an OM file.
• COPY Copy of an archive file.
Used to transfer the contents and characteristics (FIAF, FCDF) of a file. If the file
is handled by FOCE, the space reserved in FOCE for the file is transferred.
• RART Copy of an archive file and restructuring by the catalogue.
Used to transfer the contents of a file item by item, with padding or truncation
according to the item and/or record sizes defined in the source and the desti-
nation. If the file is handled by FOCE, the space reserved in FOCE for the file
is transferred.
• RSTR Copy of an archive file and restructuring by the OM structure.
Used to transfer the contents of a file field by field according to source and desti-
nation structures. Fields described in the destination structure and in the source
structure are copied, with padding or truncation if necessary. Fields described
in the destination structure but not present in the source structure are reset to
zero. Zones not described in the destination structure are set to zero. If the file
is handled by FOCE, the space reserved in FOCE for the file is transferred.
Used in cases of incompatible change in item structure.
• RPY Copy of permanent data from an archive file.
Used for the mixed files, this mode allows for a transfer of the permanent data
stored in a source file towards a destination file. The non-permanent data of
the destination file remain unchanged.
Depending on the file type given in FCDF, the data with the following types are
considered as permanent:
- system,
- system and country,
- system, country and contract.
The data types are specified in the structures used to describe the file. The
structures themselves are described in the YSTR file of the OM.
MODE OPERATING MODE FOR RAE
- Parameter symbolic name
- The value is assigned in the form : A-B
- A : Operating mode for congestion level 1
- B : Operating mode for congestion level 2

124 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- A and B are 0 or 1
MODF COUPLER INTERFACES OPERATING MODE
- Parameter symbolic name:
- possible values: 0 ≤ MODF ≤ 3
- MODF = 0 : 10 Megabits/s in Half-Duplex
- MODF = 1 : 10 Megabits/s in Full-Duplex
- MODF = 2 : 100 Megabits/s in Half-Duplex
- MODF = 3 : 100 Megabits/s in Full-Duplex
MODI MODIFICATION
- Parameter value.
MODS OPERATING MODE FOR RES
- Parameter symbolic name
- The value is assigned in the form : A-B-C
- A : Operating mode for congestion level 1
- B : Operating mode for congestion level 2
- C : Operating mode for congestion level 3
- A, B and C are 0 or 1
MOY MEAN VALUE OF LINE CHARACTERISTIC MEASUREMENTS
- Symbolic name printed out
MPR MULTI-PROTOCOL COUPLER
- SFCA parameter value
MQ GROUP OF MARKERS
- Value of parameter
MQ MESSAGE DISTRIBUTOR ML GROUP
- Parameter value
MQ ML MQ
- TYML parameter value
MQ1 MARKER NUMBER 1
- Parameter value
MQ1 MESSAGE DISTRIBUTOR 1 ML
- Parameter value
MQ2 MARKER NUMBER 2
- Parameter value
MQ2 MESSAGE DISTRIBUTOR 2 ML
- Parameter value
MRn MULTIREGISTER NUMBER N

3BW 45305 AAAA RKAHA Ed. 07 125 / 236


SYMBOL DICTIONARY

- Parameter value
- 1≤n≤7
MR CALL HANDLER ML GROUP
- Parameter value
MR ML MR
- TYML parameter value
MRCC1 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 1
- Parameter value
MRCC2 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 2
- Parameter value
MRCC3 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 3
- Parameter value
MRCC4 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 4
- Parameter value
MRCC5 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 5
- Parameter value
MRCC6 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 6
- Parameter value
MRCC7 MULTIREGISTER / COMMUNICATION CONTROLLER NUMBER 7
- Parameter value
MRIn NON-DEDICATED MARKS FOR IN-CS1 SERVICES
- Value of parameter MAR
- 1 ≤ n ≤ 32 (NON EXCLUSIVE)
MR1 MULTIREGISTER NUMBER 1
- Parameter value
MR1 CALL HANDLER 1 ML
- Parameter value
MR2 MULTIREGISTER NUMBER 2
- Parameter value
MR2 CALL HANDLER 2 ML
- Parameter value
MR3 MULTIREGISTER NUMBER 3
- Parameter value
MR3 CALL HANDLER 3 ML
- Parameter value
MR4 MULTIREGISTER NUMBER 4

126 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Parameter value
MR4 CALL HANDLER 4 ML
- Parameter value
MR5 MULTIREGISTER NUMBER 5
- Parameter value
MR5 CALL HANDLER 5 ML
- Parameter value
MR6 CALL HANDLER 6 ML
- Parameter value
MR7 CALL HANDLER 7 ML
- Parameter value
MS Manual switch
- Value of the parameter REQ
MS OUTPUT MESHES
- Value of parameter
MSA OM SECONDARY MEMORY A
- Parameter value
MSB OM SECONDARY MEMORY B
- Parameter value
MSK DATA TYPE
- Symbolic parameter name
- Possible values:
• <list> : SYS, PAY, AFF, BUR or TMP
• <item> : NOMSK
- IDLIN
- MSK defines the data on which the cheksum is calculated.
• hd.Mnemonic hd.Checksum recalculated on
• SYS "System" data (permanent system files and data classed as system data in
mixed permanent files).
• PAY "Country" data (permanent Country files and "country" data in mixed per-
manent files).
• AFF "Contract" data (permanent contract files and "contract" data in mixed per-
manent files).
• BUR "Office" data (semi-permanent files and "office" data in mixed permanent
files).
• TMP "Temporary" data (temporary files and "temporary" data in mixed perma-
nent files).
• NOMSK All data

3BW 45305 AAAA RKAHA Ed. 07 127 / 236


SYMBOL DICTIONARY

- ARCCO
- MSK defines the data to be copied.
• hd.Mnemonic hd.Data copied
• SYS "System" data
Identification
• PAY "Country" data
• AFF "Contract" data
• BUR "Office" data
• TMP "Temporary" data
• NOMSK All data
Identification
MSO OM SECONDARY MEMORY
- Symbolic parameter name
OM secondary memory comprises a set of disk files which are all required to execute
the OM function. There are two OM secondary memories, one active and the other
comprising a work space for software upgrades.
- Possible values:
- MSA, MSB
MTDi INHIBITION MODE OF ECHO CANCELLERS WITH REGARD TO MODEMS
- Value of the parameter AECHO
- Possible values:
- i=1 no inhibition
- i=2 inhibition in mode G164
- i=3 inhibition in mode G165 (default value)
MTE TRAFFIC MEASUREMENT OVER THE DESTINATION IN ERLANGS
- Symbolic output name
MTI INDICATOR FOR INTERNATIONAL TRANSIT
- Parameter value
- Parameter : DIS
MTT FUNCTIONAL ADDRESS OF THE FRAME PROCESSING MODULE
- Symbolic name of parameter
- The value is assigned in the form :
- <UR>-<MTT> where :
- UR : connection unit number
- MTT : number of the Frame Processing Module
- comprised between 0 and 1
MTX CHARGING MODE

128 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- MTX = Q - P1 - P2 with :
- Q = initial charge
- P1 = time band in S (0 to 3600)
- P2 = time band in mS (0 to 990)
- P1-P2 : 500 mS to 1 H
MTX CHARGE MODIFICATION
- DIS parameter value
MUX Multiplexing/demultiplexing 34 Mbits function
- Value of parameter ENS
N DIAGNOSTIC NUMBER OF REPAIR COMMAND
- Symbolic name of parameter
- Decimal integer
N NATIONAL
- Value of ANDL parameter
N RINGING NUMBER OF SECONDS
- Symbolic name of parameter
- The parameter is associated to PRC in command OLXLA
N POSSIBLE STATUS OF GVS
- Value of parameter
N CHARGING PERIOD DIVIDER
- Symbolic name of parameter
- Possible values : 1 to 255
Ni INDE 2-wire
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15
N SIGNALLINK LINK TRANSMISSION RATE (64kbits/second)
- Value of parameter D
N NUMBER OF ITEMS TO OUTPUT
- Symbolic name of parameter
N REFUSAL, NOT AUTHORIZED
- Parameter value
N NATIONAL
- Value of ANDL parameter
NAn ENTITLED TO SHORT-CODE DIALLING
- Value of parameter CAT

3BW 45305 AAAA RKAHA Ed. 07 129 / 236


SYMBOL DICTIONARY

- 1 ≤ n ≤ 16
- Number of 5 short code partition
NAAPR NUMBER OF USI (SIGNALLING UNIT) ACTIVATIONS PER PROCEDURE CALL
- Symbolic name printed out.
NAC CANNOT BE ACCESSED
- Symbolic name printed out
NACOP NUMBER OF USI ACTIVATIONS PER PERIPHERAL COMMAND
- Symbolic name printed out
NACT CRC4 NON ACTIVE ON PCM
- Value of parameter CRC
NAEF NUMBER OF COMPLETED CALL
- Symbolic name printed out
NAFF ET NOT ASSIGNED
- Parameter setting
- STATUS or symbolic name in an output line
- ET not installed
NAFF UNASSIGNED NE
- Symbolic name output
NAI NUMBER OF CALL ON HAND /IMMEDIATE ACCES CALL
- Symbolic name of parameter
- It is a directory number (Sce ND)
NALV NUMBER OF SHELF
- Symbolic name printed out
- 3 decimal integers
NAME FILE NAME
- Symbolic name printed out
NAME RECORD NAME
- Symbolic name of parameter
- 6 characters as a maximum
NAME NAME OF FAULTS FILTER
- Symbolic name of parameter.
- Values : EDAV, EDAR, ENBM.
NAME NAME OF KEYWORD OWNER
- Symbolic name of parameter.
- From 1 to 10 alphadigital characters.
NOM NAME OF THE MESSAGE TRANSMITTED BY THE URA2G

130 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- Possible values :
- ODIAG : Spontaneous diagnostic message
- ODILO : LOCAVAR diagnostic message
- ODPTE : LOCAVAR activation request message
NAO NUMBER OF CALLS OFFERED
- Symbolic name in output lists.
NAP PORT ACCESS NUMBER (V5.1 OR V5.2 ADDRESS)
- Symbolic name of parameter
- Possible values : 0 à 8175 for ISDN CPEs 0 à 32767 for the analogue subscribers
NAP NUMBER OF CALLS PROCESSED
- Symbolic name of parameter in output list
NAPI ARCHIVE NUMBER TO BE DOWNLOADED IN THE PILOT LOGIC UNIT (CSN)
- Symbolic name of parameter
- Possible values : 8 to 9 for CSN1G
- 10 to 11 for CSNHD
NAPU The threshold as a minimum number of calls handled to indicate UR inefficiency
- Symbolic parameter name
- The value is given in number of calls
NAR DESIGNATION NUMBER OF A TRANSFER
- Symbolic name of parameter
- It is a directory number
NAR COMPLETE DIALLING TO BE RE-ANALYZED
- Parameter value
- From 1 to 24 digits
NARCAi NUMBER OF ATM LINK
- value of parameter RAN
• value from 1 to 128
NARE ARCHIVE NUMBER TO BE DOWNLOADED IN THE STANDBY LOGIC UNIT (CSN)
- Symbolic name of parameter
- Possible values : 8 to 9 for CSN1G
- 10 to 11 for CSNHD
NARN NIGHT TRANSFER DESIGNATION NUMBER
- Symbolic name of parameter
NASA NUMBER OF ACTIVATIONS PER WAIT PERIOD FOR SUPERVISING SERVICE
- Symbolic name printed out

3BW 45305 AAAA RKAHA Ed. 07 131 / 236


SYMBOL DICTIONARY

NASCR NUMBER OF USI ACTIVATIONS PER POLLING


- Symbolic name printed out
NASD NUMBER OF DIRECT ACTIVATIONS FOR A SUPERVISING SERVICE
- Symbolic name printed out
NASI NUMBER OF ACTIVATIONS PER INTERJECTION FOR A SUPERVISING SERVICE
- Symbolic name printed out
NASTA NUMBER OF ACTIVATIONS OF STATISTICS PROBE
- Symbolic name printed out.
NATn SUBSCRIBER NATURE FIELD
- Value of parameter CAT
- Refer to operating data
NATC NATURE OF EQUIPEMENT
- Symbolic name printed out
NATPI NUMBER OF USI ACTIVATIONS PER IMMEDIATE TIME DELAY
- Symbolic name printed out
NATT NUMBER OF ATTRIBUTE
- Symbolic name printed out
NAV CNL RACK-SUBRACK NUMBER
- Symbolic name of parameter
- Possible values for rack - subrack :
• 1 - 3 to 1 - 6
• 2 - 2 to 2 - 6
• 3 - 2 to 3 - 6
• 4 - 2 to 4 - 6
NB NUMBER OF BLOCKS TO BE SAVED
- Symbolic name of parameter
NB MAX. NUMBER OF ITEMS LISTED
- Symbolic name of parameter
- 1 ≤ n ≤ 1023
- If the parameter is absent, the search is carried out throug the whole range.
NB NUMBER OF ITEMS GENERATED
- Symbolic name of parameter.
NB NUMBER OF TAPE MARKS TO BE SKIPPED
- Symbolic name of parameter
- Number of 1 to 4 characters characterizing the number of 1 to 9999 skips to be
performed for options SB, SBB, SF and SFB.
- (Implicit value = 1)

132 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

NB NUMBER OF XEJ TO BE TESTED


- Symbolic name of parameter
- Possible values : 1 to 64
NB NUMBER OF BLOCKS TO BE SAVED
- Number of blocks concerning itemized billing or
- observations-faults-alarms to be saved in the
- operator commands FDTIL and OFAIL.
NBAi NUMBER OF B-CHANNELS FOR A PRIMARY-RATE ACCESS
- Value of parameter TY
- Possible value : 0 ≤ i ≤ 31
NBAC MINIMUM NUMBER OF BLOCKS TO BE KEPT DURING AUTOMATIC ERASURE
- Symbolic name of parameter.
NBAF NUMBER OF CALLS ROUTED ON A CIRCUIT GROUP
- Symbolic output name
NBAP NUMBER OF CALLS FOR O/G TRAFFIC OBSERVATION
- Symbolic name printed out
- For O/G traffic observation, number of calls processed together with the number and
percentage of first selection, second selection and last selection calls handled respec-
tively, for each direction.
NBCC NUMBER OF CHARGING CONTEXTS
- Symbolic name of parameter
- Possible values : 1 to 100
- This parameter is used to limit the wait time for the release of an ML TX support station.
- If the station is not released, it is set in BLOM status as soon as the number of engaged
extensions is lower or equal to the value of the parameter.
NBCPT NUMBER OF METERS TO BE PROCESSED
- Symbolic name of parameter
NBCT NUMBER OF TERMINAL CIRCUITS IN A CIRCUIT GROUP
- Symbolic name printed out
NBE NUMBER OF RECORDS IN A UNIT FILE
- Symbolic name of parameter
- Possible values : 0 to 32767
NBE NUMBER OF MESSAGE SIGNAL UNITS SENT
- Symbolic name printed out
NBEC NUMBER OF SAMPLES DETERMINING MEASUREMENT DURATION
- Symbolic name of parameter
- Possible values : 1 to 255

3BW 45305 AAAA RKAHA Ed. 07 133 / 236


SYMBOL DICTIONARY

NBEL NUMBER OF MESSAGE SIGNAL UNITS SENT


- Symbolic name in output lists
NBEQ NUMBER OF EQUIPMENTS IN A GIVEN STATUS
- Symbolic name printed out
NBEQPT TOTAL NUMBER OF EQUIPMENT ITEMS TESTED FOR POSIT.
- Symbolic name printed out
NBEQPT TOTAL NUMBER OF CIRCUITS IN GROUP TESTED FOR STAT.
- Symbolic name printed out
NBFAU NO.OF PERM. LINE CONDITIONS PER URA,URC OR BOTH
- Symbolic name printed out
NBL NUMBER OF PHYSICAL FILE BLOCKS
- Symbolic name of parameter
- 5 characters
NBL NUMBER OF FREE RECORDS
- Output symbolic name
NBLAH NUMBER OF LAH CONNECTED TO A TCA ETU
- Parameter symbolic name
- Can vary from 0 to 2, default is 0.
NBLL LOCALLY UN-ISOLATED V5.1 ACCESS
- Value of the parameter STTUS (ETAT) of the command TELEMO
NBLLP NUMBER OF PERMANENT LOGIC LINKS ON THE ACCESS
- Symbolic name printed out
NBLO SIGNALLING LINK NOT ISOLATED
- Value of parameter ETCS
NBLS NUMBER OF LSs CREATED
- Output symbolic name
NBPO NUMBER OF OPS. POSITIONS IN ONE CLASS
- Symbolic name printed out
NBR NUMBER OF MESSAGE SIGNAL UNITS RECEIVED
- Symbolic name printed out
NBRE NUMBER OF INPUT POINTS OF A URA INPUT SECTION
- Symbolic name printed out
NBRL NUMBER OF SIGNAL UNITS RECEIVED
- Symbolic name in output lists
NBRS NUMBER OF ATTEMPTS AUTHORIZED ON THIS ROUTING
- Value of parameter CAR

134 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible value : 1 < n < 15


NBSi TYPE OF ACCESS
- Value of parameter TY
- Possible value : 0 ≤ i ≤ 2
NCAi NO. OF B, O/G DEDICATED CHANNELS, ON ACCESS
- Value of parameter TY
- Possible value : 1 ≤ i ≤ 30
NCBi NO. OF B, I/C DEDICATED CHANNELS, ON ACCESS
- Value of parameter TY
- Possible value : 1 ≤ i ≤ 30
NCCFH LIMIT FOR NUMBER OF CONF. CIRCUITS OUT OF SERVICE
- Symbolic name of parameter
- Attributed value in percentage
NCD NUMBER OF DIRECTED CIRCUITS
- Symbolic output name
NCDE NUMBER OF DIGITS TO BE SENT
- Symbolic name of parameter
- Possible value : from 1 to 15
NCE CHANNEL NUMBER ON INCOMING EQUIPMENT
- Symbolic name of parameter
NCHA HALF EXCHANGE NUMBER
- Symbolic parameter name
- Possible values : A or B
- Used to divide the system into two units during the operations of a change of technical
release.
NCNT SIGNALLING LINK UNCONNECTED
- Symbolic name output
NCPL COUPLER NUMBER
- Parameter symbolic name:
- possible values: 0 ≤ NCPL ≤ 3
NCR ANALYSIS NOT CREATED
- Value of parameter ACCE
NCS CHANNEL NUMBER ON OUTGOING EQUIPMENT
- Symbolic name of parameter
NCTO NAME OF TRAFFIC FLOW PRINTOUT
- Symbolic name printed out
- It is made up by the name of the type of service

3BW 45305 AAAA RKAHA Ed. 07 135 / 236


SYMBOL DICTIONARY

- in association with the name of origin of a call.


NCTX NUMBER OF CHARGE ACCOUNT FOR A SUBSCRIBER
- Symbolic name printed out
NCVA ALARM MULTIPLEX NUMBER
- Parameter symbolic name:
- Possible values: 1 to 3 for the SMBs
- 1 to 4 for the other control stations (except SMB)
ND SUBSCRIBER’S DESIGNATION NUMBER
- Symbolic name of parameter
- The value is applied in the form :
- ABPQMCDU or ABPQXCDU
- Symbols A, B, P, Q, M, C, D, U represent figures 0 to 9
- X represents a letter (A, J, S or C)
NDA NUMBER OF THRESHOLD OVERFLOWS FOR ADAPTOR QUEUES
- Symbolic name printed out.
NDA NUMBER OF THRESHOLD OVERFLOWS OF ADAPTATOR QUEUE
- Symbolic name printed out
NDA DESIGNATION NUMBER ASSIGNED TO RECEIVED CALL
- Symbolic output name
NDC LIMIT FOR SHORT CODE NUMB. AND THEIR CORRES. ND’S
- Symbolic name of parameter
- On the form < NC - ND >
- The value for the < NC > depends on the NAn category
NDCNF NUMBER OF 50MS STEPS FOR THE PCM ALARM START CONFIRMATION TIMEOUT
- Name of symbolic parameter
- Value from 2 to 20
ND-DE CALLED’S DESIGNATION NUMBER
- Output symbolic name
ND-DR CALLER’S DESIGNATION NUMBER
- Symbolic name printed out
NDE DESIGNATION NUMBER IN CALL LIMITATION MODE
- Symbolic name of parameter
- Same semantic as ND
NDEL NUMBER OF LAST FREE RECORD
- Output symbolic name
NDF NUMBER OF FILE

136 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter
NDF NUMBER OF THRESHOLD OVERFLOWS FOR COMMUNICATION QUEUES
- Symbolic name printed out.
NDG NUMBER INDICATING A PRINCIPAL OR PRIORITY GROUP
- Symbolic name of parameter
- Same semantic as ND
NDG DESIGNATION NUMBER OF PRINCIPAL GROUP
- Symbolic name of parameter
- Semantics identical to ND
NDGL NO. OF PRINCIPAL OR PRIORITY GROUP FOR OBSERV. LIGNE BY LIGNE
- Symbolic name of parameter
- Same semantics as NDG
NDGL NAME OF CLIENT DATA
- Symbolic name of parameter.
- Possible values for the parameter : :sk 1.
• hd.CLIENT DATA NAME hd.RMO215
• 1 AVCAT W_DMO_CONV
• 2 CENTRX W_FONCT_CENTREX
• 3 LFIA01 < 15 LFIA15 W_LGE_FIANA
• 18 NOSUB W_N_ABO_CDC
• 19 NTCSUB W_N_CPTX_AB
• 20 NOCSED W_N_CSED
• 21 NOCSN W_N_CSN
• 22 NOFSC W_N_FSC
• 23 NOGROU W_N_GROU
• 24 MATME W_N_MIC_ATME
• 25 NOMIL W_N_MIL
• 26 NURA2G W_N_URA2G
• 27 RFIA01 < 41 RFIA15 W_NBE_FIANA
• 42 RFPR01 < 56 RFPR15 W_NBE_FPREA
• 57 VFADE Z_V_FADE
• 58 VFADS Z_V_FADS
• 59 VFEXE Z_V_FEXE
• 60 VFEXS Z_V_FEXS
• 61 VFNAB Z_V_FNAB
• 62 VFENU Z_V_FENU

3BW 45305 AAAA RKAHA Ed. 07 137 / 236


SYMBOL DICTIONARY

• 63 VFILC Z_V_FILC
NDIV NUMBER OF DIVERG. ALLOWED IN FILE ITEM PRINTOUT
- Symbolic name of parameter
- Implicitely , the number of divergencies enabled is taken from the units configuration
file.
NDL DESIGNATION NUMBER IN A LIST
- Symbolic name of parameter
- de 5 à 16 chiffres.
NDOP OPERATOR DESIGNATION NUMBER FOR MONITORING ON TEST
- Symbolic name of parameter
- Mandatory for CSN
NDP DESIGNATION NUMBER OF A PREFERENTIAL GROUP
- Symbolic name of parameter
- Directory number (Sce ND semantics )
NDP NUMBER OF THRESHOLD OVERFLOWS ON A COMMUNICATION POOL
- Symbolic name printed out.
NDPB DIGITS OF ND FOR PACKET B (ORDINARY SUBSCRIBER)
- Symbolic name of parameter
- 1 to 16 digits.
NDPI NUMBER OF THRESHOLD OVERFLOWS ON THE INTERNAL POOL
- Symbolic name printed out.
NDPL NUMBER OF THE PREFERENTIAL GROUP TO BE OBSERVED LINE-BY LINE
- Symbolic name of parameter
- Same semantics as NDP
NDRAP NUMBER OF REQUESTS FOR HIGH-SPEED BY CYCLE
- Symbolic name printed out.
NDS ADDITIONAL DESIGNATION NUMBER (DDI)
- Symbolic name of parameter
NDST NAME OF DESTINATION
- Parameter symbolic name
NDTL NUMBER OF FAST REQUESTS PER CYCLE
- Symbolic output name
NDTTM NUMBER OF THRESHOLD OVERFLOWS OF TTMIST
- Symbolic name printed out.
NDUR DESIGNATION NUMBER OF EMERGENCY SERVICE
- Symbolic name of parameter
- On the form ZG-ND

138 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

NE SUBSCRIBER’S EQUIPMENT NUMBER


- Symbolic name of parameter
- The form :<UR> <REG> <BRO>
• UR : connection unit
• 0 ≤ REG ≤ 7 terminal strip number(CSE)
• 0 ≤ REG ≤ 39 terminal strip number(CSN)
• 0 ≤REG ≤7 terminal strip number(UR V52 with 1024 equipments)
• 0 ≤REG ≤31 terminal strip number(UR V52 with 4096 equipments)
• 0 ≤REG ≤63 terminal strip number(UR V52 with 8192 equipments)
• 0 ≤ BRO ≤ 127 pin number on terminal strip
NEAL ALARM OUTPUT NUMBER
- Symbolic parameter name
- Possible values from 1 to 32767
NECH NR OF THRESHOLD OVERFL. FOUND PRIOR TO VDU OUTPUT
- Symbolic name of parameter
NECH NO. OF SAMPLES IN METER TO IMPLICATE UNIT
- Symbolic name printed out
NED SUBSCRIBER’S O/G SECTOR
- Symbolic name of parameter
- Same semantics as NE
NE-DE CALLED’S CONNECTION NUMBER
- Symbolic name printed out
NE-DR CALLER’S CONNECTION NUMBER
- Symbolic name printed out
NEE I/C SUBSCRIBER EQUIPMENT NUMBER
- Symbolic name of parameter
- Same semantics as NE
NEFIL TARGET FILE NAME IN THE LOGICAL DISK
- Symbolic name of parameter
- String including 1 to 8 characters
- (ex : FSAUV311)
NEI SUBSCRIBER LINE SECTION USED FOR DIRECTED CALLS
- Symbolic name of parameter
- Same semantics as NE
NENG EQUIPMENT Nº 7 NON ENGAGED
- Value of parameter STTUS

3BW 45305 AAAA RKAHA Ed. 07 139 / 236


SYMBOL DICTIONARY

NENLI NUMBER OF FREE REGISTERS PER CYCLE


- Symbolic name printed out
NEQ EQUIPMENT NOT EQUIPPED
- Value of parameter
NEQ CONTROL STATION NOT INSTALLED
- Parameter value
NEQ MULTIPLEX RING NOT FITTED
- Output symbolic name
NEQ ETU OR ET NOT FITTED
- STATUS or symbolic name in an output line
NEQ NOT INSTALLED
- Parameter value
NEQPT NUMBER OF URA EQUIPMENT
- Symbolic name printed out
NERAP NUMBER OF HIGH-SPEED RUN PER CYCLE
- Symbolic name printed out
NES O/G SUBSCRIBER EQUIPMENT NUMBER
- Symbolic name of parameter
- Same semantics as NE
NES SOFTWARE MACHINE NOT IN OPERATION
- Parameter value
- The host SM is in status BLOM, BLOS, INIT or TEST.
NES ET NOT IN SERVICE
- Parameter setting
- STATUS or symbolic name in an output line
- ET not handling traffic
NEXC (INCORRECT) END OF PROCESSING EXECUTION
- Symbolic name printed out
NF NOT FILTERED
- Value of parameter
NFA NUMBER OF SUBSCRIBERS IN PERMANENT CONDITION AND/OR FAULTY
- Symbolic name of parameter
- The value is indicated in number of subscribers
NFAU No. OF ADDRESSES OF FAULTY CIRCUITS OR EQUIPMENT IN PERMANENT CONDI-
TION TO LIST PER UR
- Symbolic name of parameter
- The value is applied in the form <n> where n is included between 1 and 1024

140 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- If the NFAU parameter is omitted, the system will list all the equipment units concerned
in each UR.
- On output, the NFAU value is the number of subscribers in permanent condition in
the UR.
NFC CIRCUIT GROUP NAME - SAMPLING
- Symbolic name of parameter
- NFC = <NFSC>-<P>
• <NFSC> = Circuit group name
• <P> = Sampling frequency ( 1 < P < 255 )
NFIC FILE NUMBER
- Symbolic parameter name
- Possible values : 1 to n-1
- A file number corresponds to an entry in the FIAF catalogue of an archive; n is equal
to the number of FIAF file records.
NFICD DESTINATION FILE NUMBER
- Symbolic parameter name
- Possible values : 1 to n-1
- A file number corresponds to an entry in the FIAF catalogue of an archive; n is equal
to the number of FIAF file records.
NFICH FILE NUMBER
- Symbolic parameter name
- Possible values : 1 to n-1
- A file number corresponds to an entry in the FIAF catalogue of an archive; n is equal
to the number of FIAF file records.
NFICH FILE NUMBER
- Symbolic name of parameter
- Implicitely all files. A file number is corresponding to a record in file FIAF
- As a maximum 8 values or 2 limit values.
NFICS SOURCE FILE NUMBER
- Symbolic parameter name
- Possible values : 1 to n-1
- A file number corresponds to an entry in the FIAF catalogue of an archive; n is equal
to the number of FIAF file records.
NFSC CIRCUIT GROUP NAME
- Symbolic name of parameter
- The parameter is given in the form LAAAA where L is an alphabetic character and A
an alphanumeric character.
- In traffic observation, the LOC value identifies the local traffic group circuit.
NFSIG SIGNALLING FREQUENCY NUMBER

3BW 45305 AAAA RKAHA Ed. 07 141 / 236


SYMBOL DICTIONARY

- Symbolic name of parameter


- Possible values : 0 to 255
NFSM SIGNALLING LINK SET NAME
- Symbolic name of parameter
- 5 alphanumeric characters as a maximum
NFSMi SIGNALLING LINK SET OF RANK i
- Symbolic name in output lists
NFSP NAME OF CNSPE CRCT GROUP
- Symbolic name of parameter
NFXAC THRESHOLD OF NUMBER OF FAULTY CALLS IN THE EXCH.
- Symbolic name of parameter
- Quantity of subscribers
NI GFU NETWORK IDENTITY
- Symbolic name of parameter
- Possible values : dialling : from 1 to 4 digit(s) from 0 to 9
NIDAL ALARM IDENTIFICATION NUMBER
- Symbolic parameter name
- Possible values from 1 to 1000
NILIH TRESHOLD OF NUMBER CHANNELS TOLERATED
- Symbolic name of parameter
NIN INITIAL SELECTION DIGITS TO BE FORWARDED
- DIS parameter value
NINH SIGNALLING LINK NOT INHIBITED
- Value of parameter ETCS
NITSQ NUMBER OF 1-ms ITs LOST
- Symbolic output name
NIV MAP PRINTOUT LEVEL
- Symbolic parameter name
- Possible values :
- 0 : Layout map of all the files
- 1 : Memory map of the boards (capacity and utilization)
- 2 : Memory map of the boards (capacity and utilization per archive)
NIV ADDITIONAL DETAILS FOR GLRS
- Parameter symbolic name
- Possible value :
• T : Temporary network characteristics

142 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• A : ATM network characteristics (only if RCH)


• E : End characteristics
• L : GLR LA characteristics
• I : characteristics of the Intermediate level between the network and the end
(only if RCX)
NIV SEVERITY LEVEL FOR MALFUNCTIONS
- Symbolic name of parameter
- Possible values according to the command:
• FEMAR, FEMIL, FEMLA : 2 to 3
• FFIMO : 1 to 3
NIV LIKELIHOOD OF IMPLIC., GIVEN IN DIAGNOSTIC REPORT
- Symbolic name printed out
- NIV = 1 or 2
- Level 1 concerns the elements accused
- which are most probably involved.
NIV OUTPUT LEVEL IN SOFTWARE AND DATA IDENTIFICATION
- Symbolic parameter name
- Possible values :
• ARC, ENR, FIC, SYS
NIVS SYSTEM OPERATING LEVEL
- Symbolic parameter name
The system operating level is used to sequence the initialization of the system in man-
ual mode.
- Possible values (0 to 255) :
- 64 <= Initialization of control MLs is authorised.
- 48 <= Initialization of exchanghe management MLs is authorised.
- 32 <= Initialization of the switching matrix is authorised.
- 16 <= Initialization of connection and auxiliary equipment MLs
- is authorized.
NJO DAY NUMBER
- Symbolic name of parameter
- Value : from 1 (Monday) to 7 (Sunday)
- Parameter absent : the current day is used
NLAn LIST n OF 10 SHORT-CODE NUMBERS
- Value of parameter CAT (CENTREX) : CAT=NLAn
- SYMBOLIC NAME OF PARAMETER : NLA=N
- 1 ≤ n ≤ 1023

3BW 45305 AAAA RKAHA Ed. 07 143 / 236


SYMBOL DICTIONARY

NLBn LIST n OF 100 SHORT-CODE NUMBERS


- Value of parameter CAT (CENTREX) : CAT=NLBn
- 1 ≤ n ≤ 511
NLD LOGIC NUMBER OF A DATA LINK
- Symbolic name of parameter
- Value : 1 to 255 for TYLD 1 and 2,
- 1 to 1023 for TYLD > 2
NLD LOGIC NUMBER OF A DATA LINK
- Symbolic name of parameter
- Value : 1 to 255 for TYLD 1 and 2,
- 1 to 1023 for TYLD > 2
NLD LOGIC NUMBER OF A DATA LINK
- Symbolic name output
- Value : 1 to 255 for TYLD 1 and 2,
- 1 to 1023 for TYLD > 2
NLIEN ETHERNET LINK NUMBER
- Symbolic name printed out
NLLP PERMANENT LOGIC LINK NUMBER
- Symbolic name of parameter
NLOC ROOM NUMBER FOR A REMOTE SITE
- Symbolic name of parameter
NMAS CONNECTING MULTIPLEX NUMBER
- Parameter symbolic name
- Possible values:
- 0 = MIS
- 1 = MAS1
- 2 = MAS2
- 3 = MAS3
- 4 = MAS4 value not allowed for the SMBs
NMCA BOARD NAME
- Symbolic name of parameter
- Possible values for the parameter :
- ICTRQ
NMEA NUMBER OF MESSAGES SENT BY A SM ON A RING
- Symbolic name printed out
NMEML NUMBER OF MESSAGES SENT BY THE COMPONENT

144 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name printed out


NMEN NUMBER OF MESSAGES SENT BY A SM ON A RING WITH NEGATIVE ACKNOWLEDGE-
MENT
- Symbolic name printed out
NMI INTERNAL THOUSANDS GROUP NUMBER
- Symbolic name of parameter
- Possible value : 1 to 255
NMNR NUMBER OF MESSAGES NON-RECEIVED FROM THE MULTIPLEX
- Symbolic name printed out
NMRA NUMBER OF MESSAGES RECEIVED BY A SM ON A RING
- Symbolic name printed out
NMRD NUMBER OF MESSAGES RECEIVED FROM SEQUENCES BY A SM ON A RING
- Symbolic name printed out
NMRI NUMBER OF INCOHERENT MESSAGES RECEIVED BY A SM ON A RING
- Symbolic name printed out
NMRML NUMBER OF MESSAGES RECEIVED BY THE COMPONENT
- Symbolic name printed out
NMU RE-UNHOOKING PROHIBITED
- Value of parameter CAT
NNU SPARE NUMBER
- Symbolic name printed out
NNU SECONDARY MEMORY NOT USED
- Parameter value
NO No significant
- Value of the parameter REQ
NO REFUSAL, NON AUTHORIZATION
- Value of parameter
NO NO
- Parameter value
NOART RECORD NUMBER
- Symbol printout value
NOBJ OBJECT NUMBER
- Symbolic name printed out
NOCT BYTE NUMBER IN THE SECTOR
- Symbolic name of Parameter.
- Hexadecimal number coded on 16 bits.
- Lower limit NOCT=0

3BW 45305 AAAA RKAHA Ed. 07 145 / 236


SYMBOL DICTIONARY

- Upper limit NOCT=physical sectorization -1


• Upper limit NOCT = 255 for a physical sectorization of 256
• Upper limit NOCT = 511 for a physical sectorization of 512
- By default NOCT = 0 , first byte of the sector.
NOE NUMBER OF KILO-BYTES SENT
- Symbolic name in output lists
NOKA Applique Error
- Value of the parameter TEST
NOKB Board error
- Value of the parameter TEST
NOMBU EXCHANGE NAME
- Symbolic parameter name
- String of maximum 6 characters
NOMES OBSTX MESSAGE NUMBER
- Symbolic name printed out
NOMS NAME OF FILE STRUCTURE
- Symbolic name of parameter
- Name of the structure used in the following commands:
- ARCIN, ARCMO, ARCSU.
The name on 6 characters maximum must exist in the file of OM structures.
The default value for an OM file is derived from the LFN:
- Fxxxx1 where xxxx is the LFN on 4 characters
The default value for an archive file is:
• ZZiii1 iii file number, iii < 2
• ZZiii1 iii file number, iii < 10 and system archive (Zxxx)
• xyjjj1 xy Prefix allocated to the archive, jjj < 999
• Yyjjj1 y 2nd letter of the prefix, jjj+1000 file number
• FDV64M Other instances (no prefix allocated).
List of archive prefixes:
• hd.xy hd.Archive
• ZS ZSM
• ZM ZMR
• ZX ZTX
• ZR ZTR
• ZQ ZMQ
• ZE ZETA

146 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• ZC ZCOM
• ZU ZURM
• ZY ZOC
• ZO ZOTD
• XS XASM
• XX XATX
• XR XATR
• XQ XAMQ
• X7 XUTC
For the OM files of types CLE or DIR there are no constraints of compatibility con-
cerning size between the record and the structure used. If the structure is too ’short’,
only the beginning of the record will be reached. If it is too ’long’, the modifications
performed beyond the real size wil be ineffective.
For the archive files the same principle is retained, knowing that the size of the items
is always determined by LGA of FIAF.
For the OM files of DEV type, the size of the structure determines a file division in slices
having that size and identified by NUM.
NOMSK ALL DATA
- Parameter value
NOM1 RECORD NAME
- Symbolic name of parameter.
NOM2 RECORD NAME
- Symbolic name of parameter.
NOP REFERENCE OPERATOR NUMBER
- Value of parameter
NOP OPERATOR NUMBER PERMANENT MONITORING
- Symbolic name of parameter
- possible values : 1 to 128
NOP CANNOT BE CUSTOMIZED
- Parameter value
NOR NUMBER OF KILO-BYTES RECEIVED
- Symbolic name in output lists
NORD DIAGNOSTIC SERIAL NUMBER
- Symbolic name printed out
NORG NUMBER IN THE TYPE OF THE UNIT OR OF THE TRANSMIT OBJECT
- Symbolic name of parameter
- Source of a malfunction or alarm item
NORM NORMAL PHASE OF REMOTE UNIT CONNECTION

3BW 45305 AAAA RKAHA Ed. 07 147 / 236


SYMBOL DICTIONARY

- Value of parameter
NORON OM INITIALIZATION IN NORMAL MODE
- Parameter value
This is the normal OM function initialization mode together with insertion into the OCB
system. All operation functions are available.
This initialization option is saved for future use.
NOSEG SSOM SEGMENT NUMBER
- Symbolic parameter name
- This is the ssom segment internal number. This value is only meaningful when:
LIST=ZONEZ.
- Default value, NOSEG=0: all the segments are read.
- The values "DEB" and "NSEC" are meaningful for all the segments to be listed.
NOTES NUMBER OF BUSY CONDITIONS FOR TESO SEIZURE BUFFERS
- Symbolic output name
NPEL NUMBER OF FIRST FREE RECORD
- Output symbolic name
NPGR IDENTIFICATION OF THE PROTECTION GROUP
- Symbolic name of parameter
- In the form <TU No.> - <PGR No.> with :
• TU : termination unit
• 1 ≤ TU ≤ 128
• PGR : protection group
• 1 ≤ PGR ≤ 2
NPMD NUMBER OF DEGRADED PSEUDO-MINUTES
- Symbolic name in output list
NPR NUMBER SEIZURES
- Symbolic name printed out
NPRE NUMBER OF EFFICIENT SEIZURES
- Symbolic name printed out
NPREF PREFIX NUMBER FOR THE CSN
- Symbolic name of parameter
- Possible values : 0 to 5
NPSBU EXCHANGE SIGNALLING POINT NUMBER
- Symbolic parameter name
- List of two possible entries
- Possible values from 1 to 16383 or 1 to 16777215

148 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- For a network, according to the point code format (14, 24 or 14/24 bits), NPSBU
should express the local signalling point number in 14 bit format, the local signalling
point number in 24 bit format or a list of two signalling point numbers, the first being
in 14 bit format, the second in 24 bit format.
NQA NUMBER OF NOT EQUIPPABLE EQUIPMENT
- Symbolic name printed out
NR No Request
- Value of the parmeter REQ
NR SUBSCRIBER’S CONNECTION NUMBER ON CONNECTION UNIT
- Symbolic name of parameter
- The value is applied in the form : <UR>-<eqpt>
• <UR> being the connection number
• <eqpt> being the equipment number included between 1 and 1023 (CSE)
• <eqpt> being the equipment number included between 1 and 5119 (CSN)
• <eqpt> being the equipment number included between 1 and 1023
• or 4095 or 8191 (UR V52)
• If subscriber on URC (PCM subscriber) :
- <PCM>: = PCM number (from 0 to 3 or 15)
- <VM> : = PCM channel number
NRAEC CURRENT RAE LEVEL
- Symbolic name being output
- Current automatic congestion reduction level
- Possible values : 0 to 2
NRCN LAYOUT SLOT NUMBER FOR CNL HD
- Symbolic name of parameter
- Possible values : 0 left CNL
- 87 right CNL
NRE SUBSC. LINE CONNECTION NUMBER ON CONNECTION UNIT
- Symbolic name of parameter
- In the form : <UR> - <EQPT>
- <UR> : Connection unit
- <EQPT> : Equipment number
NREC REQU. FOR SELECT. THROUGH A NON-RECOGN. FAULTS FILTER
- Symbolic name of parameter
- Possible values : Yes or No
NRESC CURRENT RES LEVEL
- Symbolic name being printed

3BW 45305 AAAA RKAHA Ed. 07 149 / 236


SYMBOL DICTIONARY

- Reduction level during signalling congestion by UP


- Possible values : 0 to 3
NREX NUMBER OF RELEX
- Symbolic name of parameter
NRFHS THESHOLD OF FREQUENCY RECEIVERS OUT OF SERVICE
- Symbolic name of parameter
- Attributed value in percentage
NROB SUBSCRIBER’S AUTOMATIC TRANSPONDER NUMBER
- Symbolic name of parameter
- Number 1 ≤ n ≤ 64 for CSE
- Number 65 ≤ n ≤ 255 for CNE
NRON THRESHOLD OF FAULTY E-LEAD (RON) EVENTS
- possible value :0 to 255
NRP NO CHARGE WITH BACKWARD TRANSMISSION OF ANSWER SIGNAL
- DIS parameter value
NRS SUBSC. LINE O/G CONECT. NUMBER ON CONNECTION UNIT
- Symbolic name of parameter
- Same semantics as NR
NS NO SIGNIFICANT CHECK
- Symbolic name printed out
NSAE NUMBER OF ERRORED SECONDS
- Symbolic name in output list
NSDT NUMBER OF SECONDS WITH FRAMES SKIPPED
- Symbolic name in output list
NSEC NUMBER OF SECTORS
- Symbolic name of parameter
- Possible value : 1 to n
- For the DMUTIL MMC:
• Hexadecimal number.
• Upper limit n=100
NSEC NUMBER OF SECTORS
- Symbolic parameter name
- Dump size: specifies the shift, expressed in number of sectors, in relation to the be-
ginning of the zone to be listed.
- Default value, NSEC=0: the whole zone, starting from DEB, is read.
NSF NUMBER OF SUB-FILE
- Symbolic name of parameter

150 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- 4 figures as a maximum
NSG NUMBER OF RESEARCH SUB-GROUP
- Symbolic name of parameter
- Possible value : 1 or 2
NSGE NUMBER OF SEVERELY ERRORED PSEUDO-SECONDS
- Symbolic name in output list
NSIG Not significant
- Value of the parameter SST
NSMTR NON MONITORING OF MULTIFRAME IN RECEIVE MODE.
- Symbolic name of parameter
- Possible values : YES or NO
NSOC NAME OF COMPANY
- Symbolic name of parameter
NSRV NAME OF THE EXTERNAL SERVICE
- Symbolic name printed out
NSS SUBSYSTEM NUMBER
- Symbolic name of parameter
- Possible value from 1 to 255
NSW Not switching
- Value of the parameter SST
NTi MAXIMUM NUMBER OF ROUTINGS TESTED BEFORE OVERFLOW
- Value of parameter DIS
- 1≤i≤8
NTA NUMBER OF CALL ATTEMPTS ROUTED TO THE DESTINATION
- Symbolic output name
NTC NUMBER OF SIGNAL UNITS RECEIVED WITH AN INCORRECT CRT
- Symbolic name printed out
NTCL NUMBER OF SIGNAL UNITS RECEIVED WITH AN ERRONEOUS CRT
- Symbolic name in output lists
NTDE NATURE OF THE CALLED SUBSCRIBER ADDRESS
- Output symbolic name
NTDR NATURE OF THE CALLING SUBSCRIBER ADDRESS
- Output symbolic name
NTE NUMBER OF BYTES FOR SIGNAL UNITS SENT
- Symbolic name printed out
NTE NUMBER OF COMPLETED CALLS

3BW 45305 AAAA RKAHA Ed. 07 151 / 236


SYMBOL DICTIONARY

- Output symbolic name


NTCL NUMBER OF IRRATIONAL SIGNAL UNITS
- Symbolic name in output lists
NTONn TONE Nº.
- Value of parameter CAR
- Possible value : 1 ≤ n ≤ 255
NTONA TONE NUMBER
- Symbolic name of parameter
- Possible values : 0 to 127
NTP NUMBER OF BYTES FOR SIGNAL UNITS LOST
- Symbolic name printed out
NTP NUMBER OF CALL ATTEMPTS OFFERED TO THE DESTINATION
- Symbolic output name
NTCL NUMBER OF MESSAGE SIGNAL UNITS LOST BECAUSE OF CONGESTION WHEN EMIT-
TING
- Symbolic name in output lists
NTPL NUMBER OF SIGNAL UNITS LOST
- Symbolic name in output lists
NTCL NUMBER OF MESSAGE SIGNAL UNITS LOST BECAUSE OF CONGESTION
- Symbolic name in output lists
NTR NUMBER OF BYTES FOR SIGNAL UNITS RECEIVED
- Symbolic name printed out
NTR NUMBER OF CALL ATTEMPTS REJECTED DURING CALL LIMITATION
- Symbolic output name
NTRA LOCAL TRANSACTION IDENTIFIER
- Symbolic parameter name
NTS NUMBER OF REJECTED CALL ATTEMPTS FOR LACK OF OUTGOING CIRCUIT
- Output symbolic name
NTSE NOT CHARGED, WITHOUT TRANSMISSION
- Value of parameter MDTX
NTSR CALL NOT CHARGED WITHOUT REPLY SIGNAL
- Value of parameter MDTX
NTT NUMBER OF CALL ATTEMPTS EITHER ISDN CCBT OR TRANSCOM OFFERED TO THE
DESTINATION
- Symbolic output name
NUAD NUMBER OF NON-INITIALIZED ANALOG UTS WITH DIAGNOSTIC
- Symbolic output name

152 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

NUAR NUMBER OF ANALOG UTS STILL TO BE DOWNLOADED


- Symbolic output name
NUI NUMBER OF EMERGENCY SERVICE
- Symbolic name of parameter
- Possible values : 0 to 3.
NUL Value ’00’H for the path trace stuffing bytes
- Value of the parameter PTFIL
NUL OUTPUT OF ZERO RESULTS OR OF RESULTS FROM A DIVISION BY ZERO
- Value of the ED parameter
NUM RECORD-ORDER NUMBER
- Symbolic name of parameter
- 4 characters as a maximum
NUM RECORD NUMBER
- Symbolic parameter name
- Possible values from 0 to 32767
NUMA ITEM NUMBER
- Symbolic name of parameter
- Implicitely :
• For command MMTRA, first item
• 8 values or two limit values as a maximum
• For command FORMO, one item value only
NUMA NUMBER OF CDC FILE ITEM
- Symbolic parameter name
- Value of the item’s number in the record
- NUMA is mandatory with NUME
- Possible values from 0 to 32767
NUMAL ALARM NUMBER
- Symbolic name of parameter.
NUME RECORD NUMBER
- Symbolic name of parameter
- Implicitely :
• For command MMTRA, first record
• 8 values or two-limit values as a maximum
NUME NUMBER OF CDC FILE RECORD
- Symbolic parameter name
- Value of the record’s number

3BW 45305 AAAA RKAHA Ed. 07 153 / 236


SYMBOL DICTIONARY

- NUMA is mandatory with NUME


- Possible values from 0 to 32767
NUM1 RECORD NUMBER
- Symbolic name of parameter.
NUM2 BYTE SHIFT IN SECTOR
- Symbolic name of parameter.
NUM3 LENGTH OF LOGICAL RECORD IN BYTE
- Symbolic name of parameter.
NUND NUMBER OF NON-INITIALIZED DIGITAL UTS WITH DIAGNOSTIC
- Symbolic output name
NUNR NUMBER OF DIGITAL UTS STILL TO BE DOWNLOADED
- Symbolic output name
NUAD NUMBER OF NON-INITIALIZED UTPS WITH DIAGNOSTIC
- Symbolic output name
NUPR NUMBER OF UTPS STILL TO BE DOWNLOADED
- Symbolic output name
NUXD NUMBER OF NON-INITIALIZED AUXILIARY UTS WITH DIAGNOSTIC
- Symbolic output name
NUXR NUMBER OF AUXILIARY UTS STILL TO BE DOWNLOADED
- Symbolic output name
N1 THRESHOLD OF RETRANSMISSION FORCED FOLLOWING PCR METHOD
- Symbolic name of parameter
- From 1 to 127
N2 THRESHOLD OF RETRANSMISSION FORCED FOLLOWING PCR METHOD
- Symbolic name of parameter
- From 1 to 32767
OAB SUBSCRIBER OBSERVATION UPON REQUEST
- Symbolic name printed out
OBP MARK FOR PREFIX OBSERVATION
- Symbolic output name
- Parameter : MAR
OBS OBSERVATION MARK
- Symbolic name printed out
OBS OBSERVATION RECORD
- Value of parameter TYP
- Selection of ITEM code

154 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- 1 to 31 included and 33
OC OM MESSAGE ROUTER ML GROUP
- Parameter value
OC ML OC
- TYML parameter value
OCA OM MESSAGE ROUTER ML LOGIC SUBUNIT A
- Parameter value
OCA OBSERVATION OF CALLS ON INCOMING CIRCUIT
- Symbolic output name
OCB OM MESSAGE ROUTER ML LOGIC SUBUNIT B
- Parameter value
OCC1 OCCUPATION RATE OF THE FIRST ENTITY NAMED
- Symbolic name printed out
OCC2 OCCUPATION RATE OF THE SECOND ENTITY NAMED
- Symbolic name printed out
OCC3 OCCUPATION RATE OF THE THIRD ENTILY RATE
- Symbolic name printed out
OCD OBSERVATION OF CALLS ON OUTGOING CIRCUIT
- Symbolic output name
OCH PERMANENT OBSERVATIONS
- Symbolic name printed out
OCR OBSERVATION OF THE RESULT COUNTERS
- Output symbolic name
ODDA OBSERVATION UPON REQUEST OF I/C LINES
- Value of parameter MAR
ODDD OBSERVATION UPON REQUEST OF O/G LINE
- Value of parameter MAR
ODGA OBSERVATION UPON REQUEST OF I/C GROUP
- Value of parameter MAR
ODGD OPERATION ON CLIENT DATA
- Symbolic name of parameter.
- Possible values :
• CDA
• CND
ODT SOURCE OBSERVED IN TRAFFIC DISPERSION
- Value of parameter MAR

3BW 45305 AAAA RKAHA Ed. 07 155 / 236


SYMBOL DICTIONARY

OFA MEASUREMENT ACCORDING TO INCOMING CIRCUIT GROUP


- MAR parameter value
OFD MEASUREMENT ACCORDING TO OUTGOING CIRCUIT GROUP
- MAR parameter value
OFF SERVICE NOT AVAILABLE
- Parameter value
OFN OBSERVATION OF THE WRONG NUMBERS
- Output symbolic name
OiTj TCAP PROTOCOL OPERATION VERSION
- Possible values of VPRG parameter
- Variant 1:
- i value from 1 to 9
- j value from 1 to 9
- Variant 2:
- i = 09, 16, 18 or 19
- j = 1 or 2
OJS STANDBY JUNCTOR OPTION IN A CSN
- Symbolic name of parameter
- Implicit value = NO
OK Line OK
- Value of the parameter TEST
OLAC CURRENT OM INITIALIZATION OPTION
- Output symbolic name
Defines the option with which OM function was initialized.
- Possible values:
- NORON, MANON, INION, RITON, ALONE
- ICDCN, CCDCN, CMISN,
- USINE, BBUCR, SEEM
OLAF FUTURE OM INITIALIZATION OPTION
- Symbolic parameter name
Defines the option used for the next initialization of OM function. This parameter is
assigned a value before initialization of OM function is carried out.
- Possible values:
- NORON, MANON, INION, RITON, ALONE
- ICDCN, CCDCN, CMISN,
- USINE, BBUCR, SEEM
OLDX OBSERVATION OF HEAVY USER LINES

156 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter
OLGX OBS. OF HEAVY USER LINES AND LINE GROUP TYPE
- Value of MAR parameter
OLX OBSERVATION OF HIGH TRAFFIC GROUPS AND LINES
- Value of parameter
OM OM TIME CHOSEN AS SYSTEM TIME
- Output symbolic name
OM MAINTENANCE ORGAN ARCHIVES
- Value of parameter REG
- Identification of the source of regeneration for a UR.
OMA URA LOAD OBSERVATION
- Value of parameter
OMNEW CONVERSION OF OM TO TECHNICAL RELEASE PN+X
- Parameter value
This mode allows the OM to be converted to technical release Pn+x followed by ini-
tialization of OM function and insertion into the OCB system (equivalent to NORON).
The execution of this option corresponds to stage 1 of the general procedure of tech-
nical release updating.
The initialization option for the future is set to NORON.
OMOLD RETURN OF OM TO TECHNICAL RELEASE PN
- Parameter value
This mode allows the OM to be returned to technical release Pn followed by initializa-
tion of OM function and insertion into the OCB system (equivalent to NORON).
The initialization option for the future is set to NORON.
ON SERVICE PROVIDED WITHOUT RESTRICTION
- Parameter value
OPES Operational state
- Symbolic name in edition
- It can take the following values :
• HS
• ES
OPN DISK FILE OPENING OPTION
- Symbolic name of parameter
OPT PRINTOUT OPTION
- Symbolic name of parameter
- Possible values : : RIGHT, STTUS , BM
OPT PRINT OPTION OF SUBSCRIBER SYSTEMATIC TESTS
- Symbolic name printed out

3BW 45305 AAAA RKAHA Ed. 07 157 / 236


SYMBOL DICTIONARY

- Number 1 = Printout of measurement results


- of all subscriber lines
- Number 2 = Printout of measurement results
- of faulty subscriber lines
- Number 3 = Printout of faulty line numbers
- Number 4 = Printout of line numbers where
- line seriously at fault
- Default option = 2
OPT OPTION
- Symbolic name of parameter
- The parameter can take the values :
• CR : "Create" option
• TR : "Process working zone (ZT)" option
• SS : "Sub-diagram working zone" option
• LS : "List the working zone ZT" option
• AJ : "Add" option
- For the DMUTIL MMC, it can take the following values:
• INIT : "Initialize working files" option
• MODI : "Modify working files" option
• VALI : "Validate working files" option
• DVAL : "Invalidate reference files" option
OPT BUFFER FILE MANAGEMENT OPTION
- Symbolic name of parameter
- The possible value are : ETAT, SV, SC, SBE, EFF, LOC, DIS, PERM, STOP, in commands
FDTIL , OFAIL and CRAIL.
OPT MAGNETIC TAPE ARCHIVING OPTION
- Value of parameter
- The possible value are : DIR, TAMP, ETAT, SV, EFF in command TAXIL.
OPT SITE ASSIGNMENT BACKUP AND REGENERATION OPTION
- Symbolic name of parameters
- Possible values, depending on command:
• SITSV : AST, CLC, BAN, SES, FCDP, FCDL
• SITRG : AST, CLC, BAN, SES, FIC
OPT OUTPUT OPTION FOR ADAPTATORS IDENTIFICATION
- Symbolic name of parameter
- Possible value :
• 1 : Yes (by default)

158 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• 2 : No
ORAS OPTIONAL DEDICATED CALL-BACK TO OPERATOR’S TERMINAL (CCBS)
- Value of the CAT parameter
ORI PATHFINDING OBSERVATION
- Value of parameter
ORV OBSERVATION OF THE TRANSFERRED CALLS
- Output symbolic name
OSE OBSERVATION OF THE THRESHOLD OUT-OF LIMITS CONDITIONS
- Output symbolic name
OSID GONE BEYOND THE SECRECY OF CGP IDENTITY
- Value of parameter CAT
OTD OBSERVATION OF O/G TRAFFIC
- Value of parameter
OTF COMPLEMENTARY OBSERVATION ON CIRCUIT GROUPS
- Value of parameter
OTX CHARGING OBSERVATION
- Output symbolic name
OUT ALARM, RIGHT VIOLATED
- Symbolic name for printout
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
O2A04 UT HAVING 4 2-WIRE ANALOG EQUIPMENTS
- Value of parameter
O2F EQUIPMENT WITH 2 NORMAL WIRES
- Output symbolic name
O2F16 UT WITH 16 ORDINARY 2-WIRE EQUIPMENTS
- Value of parameter
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
O2Z16 UT HAVING 16 ORDINARY 2-WIRE BASIC EQUIPMENTS WITH ETSI COMPLEX
IMPEDANCE
- Value of parameter
O3F EQUIPMENT WITH 3 NORMAL WIRES

3BW 45305 AAAA RKAHA Ed. 07 159 / 236


SYMBOL DICTIONARY

- Output symbolic name


O3F16 UT WHITH 16 ORDINARY 3-WIRE EQUIPMENTS
- Value of parameter
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
O3Z16 UT HAVING 16 ORDINARY 3-WIRE BASIC EQUIPMENTS WITH ETSI COMPLEX
IMPEDANCE
- Value of parameter
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
OiTj TCAP PROTOCOL OPERATION VERSION
- Value of VPRG parameter
- i value from 1 to 9
- j value from 1 to 9
Pi INDE 4-WIRE
- Value of parameter GABC
- Possible value : 1 ≤ i ≤ 15

160 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

Pi CHARGING "STEPS"
- Value of parameter MDTX
P SAMPLING FREQUENCY
- Symbolic name of paramater
- Possible values : 5 à 200
P COMPREHENSIVE TEST OF A DIAL TELEPHONE SET
- Value of PH parameter
- This test include the following actions :
• Open-circuit time (to)
• Closed-circuit time (tf)
• ratio to/tf
• SPEED (COMPUTATION OF RATE 1/(TO+TF))
• Number of pulses transmitted
• Supply current
• Loop resistance
P FILE OF PERMANENT TYPE
- Parameter value
PA SUBSCRIBER’S EQUIPMENT NUMBER
- Symbolic name of parameter
- Possible values: from 0 to 2047
- PAR represents the subscriber’s equipment number (0 to 1023) multiplied by 1 or 2
depending on whether the operator wants to perform the test through module 0 or
through module 1.
PAR FAILURE CAUSE NUMBER
- Symbolic name printed out
- Possible value :
- PAR = 1 : system cause,
- PAR = 2 : no answer from subscriber,
- PAR = 3 : busy subscriber.
PAR COMPLEMENTARY PARAMETER OUTPUT IN THE LOCAVAR DIAGNOSTICS
- Symbolic name of parameter
- Parameter values:
• CSN:
Depending on the diagnostic, PAR provides: an LR number
• or an equipment number
• or a frame coupler number
• or a CN number

3BW 45305 AAAA RKAHA Ed. 07 161 / 236


SYMBOL DICTIONARY

• or a wire C number
• URA2G: PAR=’xy’H
Used for diagnostics U46 (EAD boards), U47 (EA0 boards) and U48 (EAS
boards), PAR provides in "y" the subscriber’s number in the board (included
between 0 and 15 maximum) and in "x" the module number which has
found the fault (module 0 or module 1). The subscriber’s equipment number
(included between 0 and 1023) can be deduced from PAR and from the
geographical address of the accused board.
PAR CHARGING INTERRUPT CAUSE NUMBER
- Symbolic name printed out
PARAM GENERAL PURPOSE PARAMETER
- Symbolic parameter name
- Possible value: FLMi mnemonic
PAY COUNTRY DATA
- Parameter value.
PA2 PALME NUMBER 2
- Parameter value
PC OMC CHANNEL POSITIONING
- Value of parameter
PC SS7 CONTROLLER ML GROUP
- Parameter value
PC ML PC
- TYML parameter value
PCA SS7 CONTROLLER ML LOGIC SUBUNIT A
- Parameter value
PCB SS7 CONTROLLER ML LOGIC SUBUNIT B
- Parameter value
PCD PERCENTAGE OF CIRCUITS TO BE DEDICATED I/C OR O/G
- Parameter symbolic name
PCR PROTOCOL FOR CRLF
- Symbolic name of parameter
- Possible value :
• YES : For a connection to OCOM
• NO : Else ( default value)
PCT PERCENTAGE OF TRAFFIC APPLIED TO A MULTIREGISTER
- Symbolic name of parameter
- Possible values : 1 to 50 %
PDE PRIORITY FOR OUTGOING CALLS

162 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- TY parameter value
PER NEW PERIOD
- Symbolic name of parameter
PER ACTIVATION PERIOD OF A PROCESSING
- Symbolic name printed out
- Symbolic name of printed out
PER INTERVAL BETWEEN CONSECUTIVE CALLS
- Symbolic name of parameter
- Possible values : 2 to 5120
PER TYPE OF TIME DELAY
- Parameter symbolic name
- Possible values:
- YES : Periodic
- NO : Unitary (default value)
PER NEW PERIOD
- Symbolic name of parameter
PERIO MEASURING DURATION
- Symbolic name of parameter
PERM$K PERMUTATION
- Symbolic name of parameter
- Possible values :
- OUI, YES, SI, NON, NO, O, Y, N.
PERM MEASUREMENT PERIOD
- Symbolic name of parameter
- Possible value : 30 or 60 minutes (30 by default)
PERM OPTION FOR PERMANENT ARCHIVING STARTUP
- Value of parameter
PG NAME OF COMMAND IN CALENDAR
- Symbolic name of parameter
- With its parameter ,the command must be enabled when put in the calendar (HOR
and DAT)
PG PROGRAM NAME
- Symbolic name of parameter
- 6 characters maximum
PGI PROGRAM NAME
- Symbolic name of parameter
- 6 characters maximum

3BW 45305 AAAA RKAHA Ed. 07 163 / 236


SYMBOL DICTIONARY

PH DESIGNATION OF MEASUREMENTS EXECUTED ON A SUBSCRIBER LINE


- Symbolic name of parameter
- Possible values :
• L, Li, RLi, A, P, Pj, RPk, K, Z, TCO, DCB, FIN for ESAB with :
- 1 ≤ i ≤ 8 or 1 ≤ i ≤le 12 depending on the type of tester;
- j = 10, 13, 14, 15 ;
- k = 13, 14.
• Li for ESSY with : 1 ≤ i ≤ 8 or 1≤ i ≤le 12 depending on the type of tester;
• L, Li, RLi, Z, FIN, with :
- 1 ≤ i ≤ 8 for ESER
- 1 ≤ i ≤ 4 for ESMB
PHA RELEASE CHANGE PHASE
- Symbolic name of parameter
- Possible values :
• CTRL Preliminary check.
• DIFA Activates a broadcast of subsystem A at an incompatible release change.
• BASC Activates a switchover to Pn+x at an incompatible release change.
• DIFB Activates a broadcast of subsystem B at an incompatible release change.
• DIFC Activates a broadcast at a compatible release change.
PHA MEASUREMENT PHASE TO BE CARRIED OUT ON A CIRCUIT (TEST ON REQUEST)
- Symbolic parameter name
- Possible values:
• PHA=1 : noise measurement (if PSOPHOMETER present and noise measure-
ment authorized),
• PHA=2 : pulse test,
• PHA=3 : transmission test.
PHASE REMOTE UNIT CONNECTION OPERATING PHASE.
- Symbolic name of parameter
PID PREFIX FOR IDT
- Parameter value
- Parameter : DIS
PILE LIST USER STACK
- Parameter value
- Parameters "DEB" and "NSEC" can be specified.
PIN PROTECTION AGAINST OVERRIDE
- Value of parameter CAT
PING Address of the protecting line

164 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


PINGS State of the protecting line
- Symbolic name in edition
PK PUBLIC KEY NUMBER
- Parameter symbolic name
PLMN CIRCUIT GROUP OF THE MOBILE PUBLIC NETWORK
- CTA parameter value
PLS PRESENCE OF A DEDICATED LINK
- Symbolic output name.
- Indicates that the PCM in alarm state supports a dedicated link.
PM PERMANENT MIXED FILE
- symbolic output name
PMD DEGRADED PSEUDO-MINUTES
- Symbolic output name.
- Identifier giving the origin of a PCM "quality alarm" indication.
PNUE NUMBERING PLAN OF THE CALLED SUBSCRIBER ADDRESS
- Output symbolic name
PO OPERATOR IDENTIFICATION
- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value 4 digits maximum
PO OC POSITIONING
- Value of parameter
POC CENTREX OPERATOR POSITION
- Value of parameter CAT
POS POSITIONING TU
- Value of parameter
POS FILE POSITION
- Symbolic name of parameter
- Takes values :
- END : end of free space
POSA POSITIONING AND ALARM UT
- Value of parameter
POSAM POSITIONING, ALARM AND MEASUREMENT TU
- Value of parameter
POSAX POSITIONING TU FOR CNE BB

3BW 45305 AAAA RKAHA Ed. 07 165 / 236


SYMBOL DICTIONARY

- Value of parameter
POSM POSITIONING AND MEASUREMENT UT
- Value of parameter
POSX POSITIONING TU FOR CNL BB
- Value of parameter
POUR- "PERCENT" MODE IN DIRECTED CALLS
CENT
- Symbolic name printed out
PP PERMANENT COUNTRY FILE
- symbolic output name
PR POWERPC PROCESSOR ON MPR COUPLER
- SFEM parameter value
PR RECONSTITUTION OF AN n-DIGIT PREFIX
- DIS parameter value
- 1 ≤ n ≤ 15
PRACi PROTOCOL SUPPORTED BY RNIS ACCESS
- Value of the TY parameter
- Possible value : 2 ≤ i ≤ 3
PRAD CONNECTION UNIT PRAD
- SYMBOLIC NAME OUTPUT
PRAD PRIMARY RATE ACCESS DIECTLY CONNECTED TO THE CORE
- Valeur du paramètre TY
PREi REQUEST FOR ANALYSIS OR PRE-ANALYSIS
- Value of CAR parameter
- 1 < i < 15
PRE PREFIX TO BE PREANALYSED
- Symbolic name of parameter
- Number of digits : 1 to 8
- Possible values per digit : 0, 1, ..., 9, A, J, S, C, D
PREA PREANALYSIS FILE NUMBER
- Symbolic name of parameter
- Possible values : 1 to 15
PREF SELECTION OF SUBSCRIBER OBSERVATIONS
- Symbolic name of parameter
- Allows the selection of the observation
- of SUBSCRIBER whase designation number
- begings by the value PREF

166 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values :
- first digit of designation number
- of subscriber : mini 3 digits,
- max 9 digits
PREF PREFERENTIAL
- Value of IDDR parameter
PREO PREFIX
- Symbolic name of parameter
- PREO = <TRAD> - <prefix>
- = <TRAD> = 1 to 15
- = <prefix> = prefix
PRES NUMBER OF NEXT PREANALYSIS
- Symbolic name of parameter
- Possible values : 1 to 15
PRF Line Profile
- Symbolic name of parameter
PRIO PRIORITY LEVEL
- Symbolic output name
PRJ1 Rejected call percentage threshold for alarm 1 of command regulation
- Symbolic parameter name
- Assigned value, in percentage
PRJ2 Rejected call percentage threshold for alarm 2 of command regulation
- Symbolic parameter name
- Assigned value, in percentage
PRJ3 Rejected call percentage threshold for alarm 3 of command regulation
- Symbolic parameter name
- Assigned value, in percentage
PRM MODIFICATION VALUE OF FILE TRVPRM
- Symbolic name of parameter
- List of up to 7 explicit strings. Each string describes a modifiable parameter of TRVPRM
among :
• TYPERACC : REM or CET connection type
• LCCTEST : simulation(1) or standard(0) monitoring report link
• TRTJDB : processing of logfile OPE or OCA, or both
• SUPJDB : output medium of logfile LAS or BM, or both
• ESN : number of alarm boards
• NRES : number or resident transactions

3BW 45305 AAAA RKAHA Ed. 07 167 / 236


SYMBOL DICTIONARY

• BM : number of magnetic tape units


PROFn CALL SCREENING PROFILE CATEGORY
- Parameter value
- Possible value : 1 ≤ n ≤ 15
PRQ PQUICC PROCESSOR WITHOUT TS FUNCTION ON MPR COUPLER
- SFEM parameter value
PRQT PQUICC PROCESSOR WITH TS FUNCTION ON MPR COUPLER
- SFEM parameter value
PRV PROTECTION AGAINST CALL FORWARDING
- Value of parameter CAT (CENTREX)
PS SIGNALLING POINT
- Symbolic name of parameter
- From 1 to 16383
PS FILE OF PERMANENT OR SEMI-PERMANENT TYPE
- Parameter value
PSE SEMAPHORE EXTENDED SIGNALLING POINT
- Symbolic name of parameter
- Possible value : from 1 to 16777215
PSE1 EXTENDED SIGNALLING POINT USED IN NORMAL MODE
- Symbolic name of parameter
- Possible values : 1 ≤ PSE1 ≤ 16777215
PSE2 EXTENDED SIGNALLING POINT USED IN BACK-UP MODE
- Symbolic name of parameter
- Possible values : 1 ≤ PSE2 ≤ 16777215
PSGE SEVERELY ERRORED PSEUDO-SECONDS
- Symbolic output name.
- Identifier giving the origin of a PCM "quality alarm" indication.
PSI PREFIX FOR IDENTIFICATION SECRECY ON CALL-PER-CALL BASIS
- Parameter value
- Parameter : DIS
PSN NATIONAL SIGNALLING POINT
- Symbolic name in an output line
- Value from 1 to 4095
PSTN ANALOGUE
- Value of parameter
PSTR NUMBER OF A YSTR STRUCTURE DESCRIBING THE RECORD

168 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name printed out


PS1$$1 NUMBER OF SIGNALLING POINT USED IN NORMAL MODE
- Symbolic name of parameter
- Possible values : 1 ≤ PS1 ≤ 16383
PS2$$1 NUMBER OF SIGNALLING POINT USED IN BACK-UP MODE
- Symbolic name of parameter
- Possible values : 1 ≤ PS2 ≤ 16383
PTE Path trace expected
- Symbolic name of parameter
PTED RANK OF ET OF THE PROTECTED LINE
- Value of parameter PTED
• From 1 to 2
PTEDS State of the protected line
- Symbolic name in edition
PTEH Value of the path trace expected (in hexadecimal)
- Symbolic name of parameter
PTFIL Value of the path trace stuffing bytes
- symbolic name of parameter
- It can take the following values :
• NUL
• ESP
PTI Path trace inhibition
- symbolic name of parameter
- It can take the following values :
• YES
• NO
PTS Path trace send
- Symbolic name of parameter
PTSH Value of the path trace send (in hexadecimal)
- Symbolic name of parameter
PTX CHARGING PARAMETER NUMBER
- Symbolic name of parameter
- Possible values : 0 to 511
PTXA CHARGE PARAMETER FOR CALLING PARTY DIVERSION
- Parameter symbolic name
- Value : 0 to 255

3BW 45305 AAAA RKAHA Ed. 07 169 / 236


SYMBOL DICTIONARY

PTXB CHARGE PARAMETER FOR CALLED PARTY DIVERSION


- Parameter symbolic name
- Value : 0 to 255
PTXM LIST OF PTXS THAT MAKE UP THE MULTIPLE PTX
- Symbolic name of parameter
PTXN CHARGING PARAMETER INDEXED LIST PTXN = PTX-i
- Parameter value with:
• Possible value: i from 1 to 128
PUP MAIN PROCESSOR
- Value of parameter SFCA
PUPE SS7 PROTOCOL HANDLER ML GROUP
- Parameter value
PUPEi SS7 PROTOCOL HANDLER i ML
- Parameter value (1 ≤le i ≤le 15)
PUPEi USER PETREL ML
- Parameter value (1 ≤ i ≤ 15)
PUPE ML PUPE
- TYML parameter value
PUS AUXILIARY PROCESSOR
- Value of parameter SFCA
PW PASSWORD
- Parameter symbolic name.
- Command option symbolic name.
- A password entered when setting the OM function in operation restriction.
- When operation is in restriction mode, the PW option of the operator commands is
compulsory.
PWO KEYWORD
- Symbolic name of parameter.
- General format : XXXYZZZ.
• XXX : String made up of 3 alphadigital characters whose first character is a letter.
• Y : CTRL-F command character.
• ZZZ : String made up of 3 alphadigital characters which is not attributed on the
display unit.
PX CHARGING MESSAGES NOT ALLOWED
- CTA parameter value
P3 SHORT PULSE REMOTE CHARGE METER TESTING
- Value of parameter PH

170 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Test run on the equipment switching to test circuits


P4 LONG PULSE REMOTE CHARGE METER TESTING
- Value of parameter PH
- Test run on the equipment switching to test circuits
P5 SHORT PULSE REMOTE CHARGE METER TESTING
- Value of parameter PH
- Test run on the subscriber equipment
- This phase has to be preceded by phase PH=DR, PH=P5 or PH=P6
P6 LONG PULSE REMOTE CHARGE METER TESTING
- Value of parameter PH
- The test is run on the subscriber equipment
- This phase has to be preceded by phase PH=DR, PH=P5 or PH=P6
P7 ON-TEST MONITORING
- Value of parameter PH
- It has to be followed by the monitoring operator number (NDOP).
P10 TEST ON DIAL TEL. SET
- Value of parameter PH
- Identical to phase P without measurements P13 and P14
P13 MEASUREMENT OF A SUBSCRIBER LINE POWER CURRENT
- Value of parameter PH
P14 MEASUREMENT OF A SUBSCRIBER LINE LOOP RESISTANCE
- Value of parameter PH
P15 TIME MEASUREMENT OF LOOP DISCONNECT VIA FLASH-BUTTON
- Value of parameter PH
QAL1 QUALITY OF AAL1 LAYER
- Value of parameter
QATM QUALITY OF ATM LAYER
- Value of parameter
QCVA NUMBER OF ALARM MULTIPLEXES IN SYSTEM
- Symbolic parameter name
- Possible values from 0 to 4
- Upon CDCMO, CVAs higher than QCVA are cancelled
QLIM QUANTITATIVE LIMIT ON USE OF THE SERVICE
- Parameter symbolic name
QMAS NUMBER OF MAS IN SYSTEM
- Symbolic parameter name

3BW 45305 AAAA RKAHA Ed. 07 171 / 236


SYMBOL DICTIONARY

- Possible values from 0 to 4


- Upon CDCMO, MASs higher than QMAS are cancelled
QTAT QUALITY OF TCA/CAT LAYER
- Value of parameter
QTD DEGRADED QUALITY OF TRANSMISSION
- Parameter value for digital subscriber
QTI UNACCEPTABLE QUALITY OF TRANSMISSION
- Parameter value for digital subscriber
QTI UNACCEPTABLE QUALITY
- Value of parameter ETAT (or STATUS)
QUAL TRANSPORT QUALITY
- Symbolic name of parameter
- Possible value : yes
Q3 SESSION
- Value of parameter.
R PATHS
- Value of parameter C
R IDLE STATE OF A REMOTE CONTROL DEVICE
- Value of parameter ETAT in operator command TCMMO
Ri SIGNALLING NETWORK i
- Value of TYR parameter
- Possibles values : 4 =< i = <8
R RECEPTION (DIRECTION)
- Parameter value
Rn SIMPLIFIED TEST IN R2
- Value of GABC parameter
- 1 ≤ n ≤ 15
R REFERENCE AREA
- Parameter value
Ri SIGNALLING NETWORK i
- Parameter value (4 ≤ i ≤ 8)
RA VALIDATION OF CARRIER NUMBER FOR TRAFFIC A
- Parameter value
- Parameter : DIS
RAn ROUTING RESTRICTION CATEGORY
- Parameter value

172 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible value : 1 ≤ n ≤ 16
RAi Routing restriction
- Value of parameter DIS
- 1 ≤i ≤ 15
RACH RANK OF ROUTING TO BE ACTIVATED
- Symbolic name of parameter
- Possible value : 1 to 3
RAIN SLOT NUMBER
- Parameter symbolic name:
- possible values: 1 ≤ RAIN ≤ 255
• Geographical address of the 1st board location in the subrack under process:
- CNFCR, CNFSU
- CNFMO used with parameter RGBAC
• absolute slot number in the shelf:
- CNFMO used with parameter ELT
RAIN INTERNATIONAL DIVERSION ALLOWED
- CAT parameter value
- Symbolic name as output
RAINH ABSOLUTE SLOT NUMBER IN THE HUB TR ITEM SHELF
- Parameter symbolic name
- possible values: 1 ≤ RAINH ≤ 255
RAL LOCAL-AUTOMATIC RECALL
- Parameter value
- Symbolic output name
RAN RANK OF ATM LINK (NARCA)
- Symbolic parameter name
- Possible values, according to the command:
• LDIL, LDMO : NARCAi
RANC SIGNALLING LINK RANK IN SIGNAL. LINK SET
- Symbolic name of parameter
- from 0 to 15 in RN, from 0 to 1 in RL
RANC SIGNALLING LINK RANK IN LINK SET
- Symbolic name output
RANF RANK OF SIGNALLING LINK SET IN ROUTING
- Symbolic name of parameter
- From 0 to 3

3BW 45305 AAAA RKAHA Ed. 07 173 / 236


SYMBOL DICTIONARY

RANG ETU RANK IN THE BRANCH IN RELATION TO ITS FUNCTION.


- Parameter symbolic name
- TCA case: ATM switching network access no. (NARCA).
- ASE1 case: ASE1 rank from 1 to 16.
- ASE2 case: ASE1 rank from 1 to 8.
- Duplex ETU case on RCX networkr: On station IASAB cople rank from
- 1 to 21.
RART COPY OF AN ARCHIVE FILE AND RESTRUCTURING BY THE CATALOGUE
- Symbolic parameter name
- Possible values:
- Used to transfer the contents of a file item by item, with padding or truncation accord-
ing to the item and/or record sizes defined in the source and the destination. If the
file is handled by FOCE, the space reserved in FOCE for the file is transferred.
RAZ RESET OF COUNTERS ACTIVATION COMMANDS
- Symbolic name of parameter.
RAZ RESET RESERVED DISK SPACE
- Symbolic parameter name
- Possible values for the following command :
• ARCAD :
- YES The space on the disk reserved for the file is reset
- NO The space on the disk reserved for the file stays unchanged
The parameter RAZ ENFORCES DSK = YES
RB VALIDATION OF CARRIER NUMBER FOR TRAFFIC B
- Parameter value
- Parameter : DIS
RB TRANSMISSION OF A LOOPED-BACK MESSAGE BY THE OC
- Value of parameter
- The answer is listed
RB ON-LINE REWINDING
- Value of parameter
RC VALIDATION OF CARRIER NUMBER FOR TRAFFIC C
- Parameter value
- Parameter : DIS
RC TRANSMISSION OF MESSAGE W/REACTION
- Value of parameter
RC CHARGING RATE RECEPTION
- Value of parameter MDTX

174 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

RCA RANK OF DIGIT FOR CONTINUING WITH PREANALYSIS OR ANALYSIS


- Symbolic name of parameter
- Possible values : 1 to 31
RCAT NUMBER OF DIGITS TO BE AWAITED
- Parameter value
- From 1 to 15
RCE RANK OF DIGIT
- Rank of the digit which substition must take place (CHA included)
- Rank of the digit where next analysis or preliminary analysis start (CHA not included)
- Symbolic name of parameter
- Possible values : 1 to 15
RCF REGENERATION FOR RECONFIGURATION
- Value of parameter
RCH RCH NETWORK
- Value of parameter
RCMA MAXIMUM RANK OF THE LAST DIGIT TO BE RECEIVED (open dialling)
- Parameter value (2 to 31)
RCMI MINIMUM RANK OF THE LAST DIGIT TO BE RECEIVED (open dialling)
- Parameter value (1 to 31)
RCONF RECONFIGURATION RULES OF A DATA LINK
- Symbolic name printed out
- Value included between 0 and 1
• 0 : no reconfiguration
• 1 : reconfiguration allowed
RCONFn RECONFIGURATION RULES OF A DATA LINK
- Symbolic name printed out
- Value included between 0 and 1
• 0 : no reconfiguration
• 1 : reconfiguration allowed
RCP PREVENTIVE CYCLIC RETRANSMISSION ERROR CORRECTION METHOD
- Value of parameter CORR
RCR RANK OF LAST DIGIT TO BE RECEIVED BEFORE SEIZURE
- Symbolic name of parameter
- Possible value : 1 to 31 (default value = 1 )
RCS RANK OF FIRST DIGIT TO BE ANALYZED
- Parameter value

3BW 45305 AAAA RKAHA Ed. 07 175 / 236


SYMBOL DICTIONARY

- From 1 to 17
RD TRANSMISSION OF MESSAGE W/DELAYED ANSWER
- Value of parameter
RDA RIGHT TO RECALL THE LAST CALLING PARTY
- Value of the CAT parameter
RDAE DELAY IN BEGINNING THE TEMPORARY ECHO PROCESSING WINDOW.
- AECHO parameter value
- The possible values are:
- i= 0 < 624 in milliseconds.
RDC RANG OF LAST DIGIT TO BE RECEIVED
- Symbolic name of parameter
- From 1 to 31
- If this parameter is associated to DIS = NUO (open dialling) it gives the minimum
number of digits to be received
RDV DIARY RECALL
- Value of parameter TY
RE TRANSFERT SIGNAL SELECTION UP TO CALLED SUBSCRIBER ANSWER
- Value of parameter MOD
REA REROUTING ON DOWN SIDE CONGESTION
- Value of DIS parameter
REBO MAGTAPE REWIND OPTION
- Symbolic name of parameter
- Possible values : YES,NO
REBOL PCM SOFTWARE LOOPBACK
- Symbolic parameter name
- 0: usual mode of operation
- 1: internal loopback
- 2: external loopback
- 3: internal and external loopback
RECH SEARCH FOR OCCURRENCE
- Parameter value.
REDU DUMP REFERENCE
- Symbolic parameter name
- Values possible : 1 to 32767
REF CALL REFERENCE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape

176 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values:
• hexadecimal number on 1 byte
REFL DURATION MEASURED ON MAIN ECHO OBSERVED
- Symbolic name of parameter output
REG CONTROL STATION LOAD SOURCE
- Symbolic parameter name
- Possible values:
• CDP : Selective load on to a counterpart SM or on to the reference or working
disk archive.
• HOM : Load on to a counterpart SM
• NON : No load
• Allows re-starting of SM to be activated.
• RCF : Load the catalogue on to the reference OM disk and the files on to the
counterpart.
• Allows a file to be extended or created.
- Default value : load on to a counterpart or on to the OM in the absence of a coun-
terpart.
- To be a counterpart, the SM must be identical with or a super-assembly of the SM to
be loaded with regard to the list of MLs.
- The standby SM is systematically loaded on to the OM disk archive.
REG IDENTIFICATION OF REGENERATION FOR A UR
- Symbolic name of parameter
- The parameter can take the following values :
• OM regeneration from the OM
• NO No regeneration
• YES Regeneration on duplicated logic
• CSN For a UR of CSN type : regeneration on a logic of another CSN
- Implicit value : YES
REGEi SYSTEM IN GENERAL RESTART STEP i
- Output symbolic name (0 ≤le i ≤le 3)
- i is the step number
- Step 0: Stop control, No. 7 and auxiliary equipment ML
- support SMs
- Step 1: Restart control ML support SMs
- Step 2: Restart No. 7 and auxiliary equipment ML support SMs
- Step 3: Initialization of No. 7 functions
- The system is in a situation of total failure.
REI NUMBER OF LLP REINITIALIZATIONS

3BW 45305 AAAA RKAHA Ed. 07 177 / 236


SYMBOL DICTIONARY

- Symbolic name in output lists


REN NUMBER OF CALL TRANSFER
- Symbolic name of parameter
- Value : 1 to 255
REP REPETITION OPTION OF COMMAND FILE (DISK FILES)
- Symbolic name of parameter
- No value may attributed
- The repetition is interrupted by CTRL-A
REP FACTOR OF TEST REPETITION
- Symbolic name of parameter
- The value given to the parameter should be incluted between 0 and 20
REP NUMBER OF ITEM OR ALARM TO BE REPEATED
- Symbolic parameter name
- Possible values from 1 to 256
REQ
- Symbolic name in edition
- It can take the following values :
• NR : No Request
• MS : Manual Switch
• FS : Forced Switch
• AS : Automatic Switch
• LOCK : Lockout of protection
• NO : No significant
REQ COMMAND OF APS FUNCTION
- Symbolic name of parameter
- The parameter can take the following values :
• CL Clear
• LOCK Lockout of protection
• FSTPG Forced switch to protecting
• FSTPD Forced switch to protected
RES RESERVED SIGNALLING POINT
- Value of parameter ACCE
RES GENERATION OF THE RESULTS OF THE LAST INCOMPLETE PERIOD
- Symbolic parameter name
- Possible values : YES or NO. (NO value by default)
RES REQUEST FOR IMMEDIATE OUTPUT OF RESULTS

178 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Parameter symbolic name


- Possible values:
- YES
- NO (default value)
RESE IP ADDRESS OF THE NETWORK
- Symbolic name printed out
REST RESTORATION
- Parameter value.
- Restoration of ctilas saved on ycnf.
RET RETORT LEVEL APPLICABLE ON THE SERVICE
- Parameter symbolic name
RF Release failed
- Value of the parameter SST
RFC08 8 FREQUENCY RECEIVER EQUIPMENTS (UT)
- Value of parameter
RFI TRANSFER ONTO SPECIFIC FILM
- Value of parameter DIS
RFNR PRESET CALL FORWARDING IF NO ANSWER
- CAT parameter value
RFO RECALL UPON CIRCUIT GROUP BUSY
- Parameter value
- Symbolic output name
RFT FORCED TRAFFIC RESTART
- Parameter symbolic name
- Possible value : YES
RGBAC RANKS OF THE VARIOUS SUBRACKS
- Parameter symbolic name:
- possible values:
• CNFCR, CNFSU : 0 ≤ RGBAC ≤ 4
• CNFMO : 1 ≤ RGBAC ≤ 4
RGET ET RANK
- Symbolic parameter name
RGFM RANK
- Symbolic parameter name
RGM HARDWARE ITEM RANK ON A BOARD
- Parameter symbolic name: RGEM

3BW 45305 AAAA RKAHA Ed. 07 179 / 236


SYMBOL DICTIONARY

- possible values: 0 to 31
- sub-agent number
RGSF CARD FUNCTIONAL SPECIALIZATION RANK
- Symbolic name of parameter
- Possible values :
• BSM agent : 0 to 5
• CLTH coupler : 0 to 1
• ETU : 0 to 31
RGSMT LOGICAL RANK OF THE SMT IN THE EXCHANGE
- Symbolic name of parameter
- Parameter value : 1 to 64
- Parameter reserved for SMT2G
RI INTERNATIONAL NETWORK
- Value of TYR parameter
RI TRANSMISSION OF A MESSAGE W/IMMEDATE ANSWER
- Value of parameter
RI INTERNATIONAL NETWORK
- Parameter value
DROIT LISTING THE ENTITLEMENTS OF INTERACTIVE TERMINALS AT INPUT AND OUTPUT
- Value of parameter
- No value can be assigned
RITON INITIALIZATION AND RESETTING OF BILLING BUFFERS
- Parameter value
This mode allows the buffering files to be reset and the disk archive XASM to be up-
dated using the data read from a station in operation. The OM is aligned in accor-
dance with the system configuration.
This option is used after reloading of the OM disks.
The initialization option for the future is set to NORON.
RLn REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- 1 ≤ n ≤ 12
- cf Ln
RL LOCAL NETWORK
- Value of parameter TYR
RL LOCAL NETWORK
- Parameter value
RLN FILTERING OF INCOMING CALLS ACTIVE

180 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter CAT


RL1 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L1
RL2 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L2
RL3 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L3
RL4 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L4
RL5 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L5
RL6 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L6
RL7 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L7
RL8 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L8
RL9 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L9
RL10 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L10
RL11 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH
- cf L11
RL12 REPEATED MEASUREMENT OF A SUBSCRIBER LINE CHARACTERISTIC
- Value of parameter PH

3BW 45305 AAAA RKAHA Ed. 07 181 / 236


SYMBOL DICTIONARY

- cf L12
RN SLOT NUMBER
- Symbolic name printed out
RN NATIONAL NETWORK
- Value of parameter TYR
- Default value
RN NATIONAL NETWORK
- Parameter value
RNDL RANK OF THE LIST DESIGNATION NUMBER
- Symbolic name of parameter
- Possible values de 1 à 5.
RNI INTER-EXCHANGE CALL : TRANSFER TO OP IF NO ANSWER
- Value of parameter : CAT
RNIS DIGITAL SUBSCRB.
- Value of parameter MAR
RNR ON PSTN CALL : FORWARDING TO OP IF NO ANSWER
- Value of CAT parameter
RNU NIGHT TRANSFER
- Value of parameter CAT
RNV DATA FORWARDING NUMBER
- Parameter symbolic name
- Value : 1 to 255
RO OPERATIONAL STANDBY SUBSYSTEM
- Symbolic name in output list (SMM)
ROB RANK OF SATELLITE ALARM COUPLER
- Output symbolic name
- Possible values 0 to 3
RPi ACCESS CODE BEFORE A NEW ANALYSIS
- Value of parameter CAR
- 1 < i < 15
RPCE RANK OF FIRST DIGIT TO BE SENT OUT
- Symbolic name of parameter
- From 1 to 15 (implicit value : 1)
RPCES Rank of the first digit of the SCCP called party
- Symbolic name of parameter
- Possibles values : 1 to 15

182 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

RPTC TIME ALLOCATION (COMPLETE OUTPUT)


- Value for ENT parameter
RPTR TIME ALLOCATION (REDUCED OUTPUT)
- Value for ENT parameter
RPY ARCHIVE FILE DATA SELECTIVE COPY
- Symbolic parameter name
• This mode is used for mixed files; with it, data of one or more types can be
copied from a source file to a destination file. Data for which the type is not
specified are not modified.
• The data types are specified in the structures used to describe the file. The
structures themselves are described in the YSTR file of the OM.
- Used without MSK parameter
- Depending on the destination file type given in FCDF, the data with the following types
are copied :
• system,
• system and country,
• system, country and contract.
- Used with MSK parameter
- MSK gives types of data to be copied
RP13 REPEATED MEASUREMENT OF A SUBSCRIBER LINE POWER CURRENT
- Value of parameter PH
RP14 REPEATED MEASUREMENT OF A SUBSCRIBER LINE LOOP RESISTANCE
- Value of parameter PH
RR REPEATERS PRESENT (BASIC ACCESS)
- TY parameter value
RSi RANK OF THE FOLLOWING DIGIT BEFORE A NEW ANALYSIS
- Value of parameter CAR
- 0 < i < 15
RSC COMMON RESOURCES
- Value of parameter ENT
RSDK PROCESSOR LOAD (ETU TCA)
- Value of parameter
RSI INTER-EXCHANGE CALL : TRANSFER TO OP IF CALLED PARTY BUSY
- Value of parameter : CAT
RSL RESOURCES ASSOCIATED WITH THE LDS COMPONENTS
- Value of parameter ENT
RSO ON PSTN CALL : FORWARDING TO OP IF CDP ENGAGED
- Value of CAT parameter

3BW 45305 AAAA RKAHA Ed. 07 183 / 236


SYMBOL DICTIONARY

RSS SPECIFIC RESOURCES


- Value of parameter ENT
RSTR COPY OF AN ARCHIVE FILE AND RESTRUCTURING BY OM STRUCTURE
- Symbolic parameter name
- Used to transfer the contents of a file field by field according to the source and destina-
tion structures . Fields described in the destination structure and in the source structure
are copied, with padding or truncation if necessary. Fields described in the destination
structure but not present in the source structure are reset to zero. Zones not described
in the destination structure are set to zero. If the file is handled by FOCE, the space
reserved in FOCE for the file is transferred.
- Used in cases of incompatible change in item structure.
RT SUB THIS VALUE TO CENTRAL TIME CLOCK RESETTING
- Symbolic name of parameter
- On the form <hour>-<minute>-<second>
RT SUB THIS VALUE TO CENTRAL TIME CLOCK RESETTING
- Symbolic name of parameter
- On the form :
• 00 ≤ hour ≤ 23
• 00 ≤ minute ≤ 59
• 00 ≤ second ≤ 59
RTAML DISTRIBUTION OF THE TIME ASSIGNED TO THE ML ON A SAME AGENT
- Symbolic name printed out
RTCML DISTRIBUTION OF THE TIME CONSUMED PER ML ON A SAME AGENT
- Symbolic name printed out
RTGMT delay of the standard time compared to hour GMT
- Symbolic name of parameter
- On the form <hour>-<minute>-<second>
- Possible values for <minute> : 00 or 30
RTI IMPLICIT RECEPTION OF CHARGING CODE
- Value of parameter MDTX
RTS CONDITIONAL REMOTE CHARGING RETRANSMISSION
- Value of parameter CTA
RTT RETRANSMISSION OF CHARGES PULSES
- Value of parameter
RUP NUMBER OF LLP INTERRUPTIONS
- Symbolic name in output lists
RVi CALL FORWARDING NUMBER
- Value of parameter DIS

184 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- 1 < i < 32
RVFO PRESET CALL FORWARDING IF LINE BUSY
- CAT parameter value
RVFT UNCONDITIONAL PRESET CALL FORWARDING
- CAT parameter value
RVO DIVERSION ON CALLED PARTY BUSY
- CAT parameter value
RVT ENTITLED TO TEMPORARY TRANSFER
- Value of parameter CAT
RVTI ENTITLEMENT TO TRANSFER OF TERMINAL
- Value of parameter CAT
RWD TAPE REWIND
- Symbolic name of parameter
- Par = BME or BMS
RZCOE RESET OF ECHO CANCELLER COEFFICIENTS
- Parameter symbolic name
- Possible values:
- YES
- NO (default value)
S POSSIBLE GVS STATUS = STANDBY
- Value of parameter
S SIGNALLING
- Value of parameter C
Sn SIMPLIFIED CIRCUIT TESTS
- Value of GABC parameter
- 1 ≤ n ≤ 15
S OUTGOING LINK SET
- Value of parameter
S OUTGOING CALLS
- Value of parameter SENS
S FILE OF SEMI-PERMANENT TYPE
- Parameter value
SAB SUPPRESSION OF ROUTING CODE DIALLED BY SUBSCR.
- Value of parameter
SABAi SUBSCRIBER AND AUXILIARY UNITS SIMULATOR ML
- Parameter value (1 ≤le i ≤le 8)

3BW 45305 AAAA RKAHA Ed. 07 185 / 236


SYMBOL DICTIONARY

SAE ERRORED SECONDS


- Symbolic output name.
- Identifier giving the origin of a PCM "quality alarm" indication.
SAIN FAULT-FREE ACCESS
- symbolic output name
- status value for a digital subscriber access
SALLE NO.OF THE RACK ROOM
- Symbolic name output
- Decimal integer (over 3 digits)
SAMi MODULAR POWER FEEDING STATION i
- Value of parameter (1 ≤ i ≤ 16)
SARA BACKWARD SIGNAL
- Parameter symbolic name
- Value : to 15
SARB LIST OF BACKWARD SIGNAL NUMBERS TO BE SENT
- Parameter symbolic name
- The value is assigned in the form <NUMBER>-<SIGNAL NUMBER>,
- NUMBER: between 1 and 15
- SIGNAL NUMBER: between 0 and 255
SAT SATELLITE INPUT
- Value of parameter CTA
SAT ROUTING OR PARAMETER OF TAXATION TYPE ACCORDING TO THE INCOMING
SATELLITE SOURCE CIRCUIT GROUP
- Value of the STY parameter
SAT Type of parameter of taxation according to the incoming satellite source circuit groupe
- Value of the STY parameter
SAVE SAVE
- Parameter value.
- CTILAS saved on YCNF.
SB DATA BLOCKS FORWARD JUMP
- Value of parameter
SBB DATA BLOCKS REARWARD JUMP
- Value of parameter
SBD DATA BLOCKS BACKWARD JUMP
- Symbolic name of parameter
SBE OUTPUT OF INCORR. BLOCKS
- Value of parameter

186 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

SBM TAPE MARK BACKWARD JUMP


- Symbolic name of parameter
SC OPERATOR SERVICE
- Symbolic name for output
- Data read from the magnetic tape of detailed billing type
- Possible values:
• decimal number between 1 and 5
DIS ARCHIVING OPTION
- Value of parameter
SCA SERVICE WITH DAY-NIGHT CHANGE OF CATEGORIE
- Value of parameter TY (CENTREX)
SCE CALL SOURCE
- Symbolic name of parameter
- The value given to the parameter can be either YES (sort of results made by source),
or NO (no sort executed).
- The default value is NO.
SCH ALL HIGH SPEED CONNECTION MULTIPROCESSOR STATIONS
- Parameter value
SCHi HIGH SPEED CONNECTION MULTIPROCESSOR STATION GROUP~i
- Parameter value (1 ≤ i ≤ 16)
SCHAi HIGH SPEED CONNECTION MULTIPROCESSOR STATION i BRANCH A
- Parameter value (1 ≤ i ≤ 16)
SCHBi HIGH SPEED CONNECTION MULTIPROCESSOR STATION i BRANCH B
- Parameter value (1 ≤ i ≤ 16)
SCS SIGNALLING LINK SELECTION
- Symbolic name output
- From 0 to 15
SCT SUB-CATEGORY
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
SCTR CAN BE CUSTOMIZED SITE BY SITE BY THE MANUFACTURER
- Parameter value
SCV23 THRESHOLD FOR AVAILABLE V23 MODULATORS
- Symbolic parameter name
- Numeric value attributed

3BW 45305 AAAA RKAHA Ed. 07 187 / 236


SYMBOL DICTIONARY

SD Signal Degraded
- Symbolic name of parameter
- It can take the following values :
• <DIXM>5
• <DIXM>6
• <DIXM>7
• <DIXM>8
• <DIXM>9
SDE POWER DISTRIBUTION SOURCE NUMBER
- Symbolic parameter name
- Possible values from 1 to 8
SDIVi RACK FOR VARIOUS UNITS i
- Value of parameter (1 ≤ i ≤ 16)
SE INPUT SECTIONS
- Value of parameter
SE URA INPUT SECTION NUMBER
- Symbolic name printed out
SEC STANDBY EQUIPMENT (FOR SAFETY CALL)
- Symbolic name printed out
SEC BACKUP CONTROL STATION
- Parameter value
- Used to look for the standby SM
SECD DESTINATION SECTOR
- Symbolic name of Parameter.
- Hexadecimal number.
- By default DEB=0, first sector of the destination.
SECR PERMANENTLY ACTIVE NON-DIVULGATION STATUS, CONTROLLED BY THE USER
- Value of the MAR parameter
SEEF THRESHOLD EFFICIENCY
- Symbolic name of parameter
- Value of parameter in percentage
SEEM TEACHING SIMULATOR FOR MAINTENANCE USE
- Parameter value
This mode allows the OM to be started up as a teaching simulator for maintenance
use. The OM functions with an LCC and some specific transactions.
This initialization option is saved for future use.
SENS DIRECTION OF MONITORED CALLS

188 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- Possible value : E, S, E+S
SENS DIRECTION OF TRANSMISSION
- Symbolic name of parameter
- Possible value : E , R , E+S
SENS SUB-UNIT OF UNIT
- Symbolic name output
SEPn ECHO SUPPRESSOR CATEGORY IN POOL
- Parameter value
- Possible value : 1 ≤ n ≤ 8
SER NO.OF THE REQUIRED SERVICE
- Symbolic name of parameter
- Possible value : from 0 to 7
SERVSUP ADDITIONAL SERVICE
- Symbolic name printed out
SES ASSIGNMENTS OF SESSION LFN.
- Value of parameter
SETA ETU SUB-STATUS
- Symbolic parameter name
- Values comprised between 0 and 4.
- 0 : Non backed-up reconfigurable ETU
- 1 : Backed-up reconfigurable ETU
- 2 : back-up ETU available
- 3 : back-up ETUbusied
- 4 : Back-up ETU unavailable
SETS Synchronisation equipment timing source (G813)
- Value of the parameter TIMQ
SEXP CAN BE CUSTOMIZED SITE BY SITE BY THE OPERATOR
- Parameter value
SF signal fail
- Value of the parameters PTEDS and PINGS
SF TAPEMARK FORWARD JUMP
- Value of parameter
SF TYPE OF FORMAT SAVING
- Symbolic name of parameter.
- Mnemonics :

3BW 45305 AAAA RKAHA Ed. 07 189 / 236


SYMBOL DICTIONARY

• YES : Saving of all subformats called for by the main format.


• NO : Saving of main format only.
SFAC INVOICING STANDBY EQUIPMENT IS ACTIVE
- Value of parameter
SFB TAPEMARK REARWARD JUMP
- Value of parameter
SFCA FUNCTIONAL SPECIFICATION OF AN ITEM
- Parameter symbolic name:
- possible values: 1 ≤ SFCA ≤ 255
SFCA CARD FUNCTIONAL SPECIALIZATION
- Symbolic name of parameter
- Possible values are : AUX, CLTH, CMP, CMS, CSS7, ETH, ETU, MPR, PUP, PUS
SFD DATA BLOCK FORWARD JUMP
- Symbolic name output
SFEM FUNCTIONAL SPECIFICATION OF A HARDWARE ELEMENT
- Symbolic parameter name
- The parameter may have one of the following values:
- PUP : Main local bus processor unit
- PUS : Secondary local bus processor unit
- CMP : Main multiplex coupler
- CMS : Secondary multiplex coupler
- ETH : 10 Mbit/sec. Ethernet coupler
- PR : Multi-protocol coupler, PowerPC processor
- PRQ : Multi-protocol coupler, PQUICC processor without TS function
- PRQT: Multi-protocol coupler, PQUICC processor with TS function
- AUX3: AUX coupler, 3 ICL/ISL PQUICC processor
- AUX2: AUX coupler, 2 ICL/ISL PQUICC processor
- AUXA: AUX coupler, MAL and HOR PQUICC processor
- ETP : ETP (generic)
SFET ET FUNCTIONAL SPECIFICATION
- Symbolic name of parameter
- Parameter setting :
- TMIC : PCM termination
- TCA : Time-division/ATM conversion
- ASE1 : First stage of the ATM switching network
- ASE2 : Second stage of the ATM switching network

190 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- TMAE : PCM termination with echo canceller


- RALS : Switching of LAH and LAHq links
- T63E1 : Connection and handling of a synchronous access at 155 Mbit/s equipped
with 63 VC12 (63 E1 PCM accesses)
- T63E1-R : same functionality as T63E1 when the board concerned is acting as pro-
tection for another which is active
- AAE : Pool echo canceller for 992 routes
- T16E1 :Connection and handling of 16 E1 PCM accesses
- TBIWU : Connection and handling of an STM1 ATM access allowing NB/BB interfunc-
tioning for the VoATM function
- TBIWU-R : same functionality as TBIWU when the board concerned is acting as pro-
tection for another which is active
- TUIWU : same functionality as TBIWU for the UMTS function
- TBATC : same functionality as TUIWU with Speech transcoding and
- rate adaptation for the UMTS function
SFM TAPE MARK FORWARD JUMP
- Symbolic name of parameter
SFNAC INVOICING STANDBY EQUIPMENT IS NOT ACTIVE
- Value of parameter
SFNAL INVOIC. STANDBY EQUIP.NOT ACTIVE(MAGT. RE-READING)
- Value of parameter
SFNAR INVOIC. STANDBY EQUIP.NOT ACTIVE(MAGT. NOT BLANK).
- Value of parameter
SG SIGNALLING SYSTEM
- Symbolic name of parameter
- SG = LiEj
SGN ALARM, SIGNATURE INVALID
- Symbolic name for printout
SGN COMMAND ABFASE OPTION WITH HOWLER
- Symbolic name of parameter
- Options : SGN = YES or SGN = NO
YES ACCEPTANCE, AUTHORIZATION
- Parameter value
SI ALARM CATEGORY: NO ACTION OUTSIDE WORKING HOURS
- Parameter value
SIDR NON-DISCLOSURE OF CALLING PARTY’S IDENTITY
- Symbolic name on output
- Output during reading of TLV france format itemized billing type magnetic tape

3BW 45305 AAAA RKAHA Ed. 07 191 / 236


SYMBOL DICTIONARY

- Possible values:
• 0 or 1
SIDR ENTITLEMENT TO CONCEALMENT OF CALLER S IDENTITY
- Value of parameter CAT
SIG SIGNALLING
- Symbolic name of parameter
- Possible value : 0 ≤ LVS ≤ 4
SIG5 CODE LINE 5 SIGNALLER FUNCTION
- Value of the parameter FACT
SIO OPTIONAL TRUNK SERVICE PRESENT
- MAR parameter value
SIRA__ Notification of call from person who’s calling
-
SIRV ENTITLEMENT TO NON-DISCLOSURE OF B IDENTITY TO C
- value of parameter CAT
SISA LIST SISA(s) CONTENT.
- Parameter value
SITE SITE FUNCTION
- Value of parameter CACT (command FZTMOS)
SM ML SM
- TYML parameter value
SMA SET OF AUXILIARY EQUIPMENT CONTROL STATIONS
- Parameter value
SMAi AUXILIARY EQUIPMENT CONTROL STATION i
- Parameter value (1 ≤le i ≤le 64)
SMB SET OF GENERAL PURPOSE CONTROL STATIONS
- Parameter value
SMBi GENERAL PURPOSE CONTROL STATION i
- Parameter value (1 ≤le i ≤le 88)
SMBAi DUPLEX GENERAL PURPOSE CONTROL STATION i LOGIC A
- Parameter value (1 ≤le i ≤le 32)
SMBBi DUPLEX GENERAL PURPOSE CONTROL STATION i LOGIC B
- Parameter value (1 ≤le i ≤le 32)
SMBDi TRUNK CONTROL STATIONS GROUP (SMBT)
- Parameter value (1 ≤le i ≤le 32)
SMBD SET OF DUPLEX GENERAL PURPOSE CONTROL STATIONS
- Parameter value

192 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

SMBDi GROUP OF DUPLEX GENERAL PURPOSE CONTROL STATIONS i


- Parameter value (1 ≤le i ≤le 32)
SMC SET OF MAIN CONTROL STATIONS
- Parameter value
SMCi MAIN CONTROL STATION i
- Parameter value (1 ≤le i ≤le 60)
SMM SET OF MAINTENANCE STATIONS
- Parameter value
SMMA MAINTENANCE STATION LOGIC SUBUNIT A
- Parameter value
SMMB MAINTENANCE STATION LOGIC SUBUNIT B
- Parameter value
SMT SET OF TRUNK CONTROL STATIONS
- Parameter value
SMTi TRUNK CONTROL STATIONS GROUP i
- Parameter value (1 ≤le i ≤le 32)
SMTAi TRUNK CONTROL STATION i - LOGIC SUBUNIT A
- Parameter value (1 ≤le i ≤le 32)
SMTBi TRUNK CONTROL STATION i - LOGIC SUBUNIT B
- Parameter value (1 ≤le i ≤le 32)
SMX SET OF MATRIX CONTROL STATIONS
- Parameter value
SMXi MATRIX CONTROL STATIONS GROUP i
- Parameter value (1 ≤le i ≤le 8)
SMXAi MATRIX CONTROL STATION i - BRANCH A
- Parameter value (1 ≤le i ≤le 8)
SMXBi MATRIX CONTROL STATION i - BRANCH B
- Parameter value (1 ≤le i ≤le 8)
SND DELAYED MESSAGE NOTIFICATION FORBIDDEN
- Value of the CAT parameter
SNI IMMEDIATE MESSAGE NOTIFICATION FORBIDDEN
- Value of the CAT parameter
SN1 SN1 SIGNATURE
- Parameter symbolic name
- In the form of a hexadecimal string of 128 characters
SN2 SN2 SIGNATURE

3BW 45305 AAAA RKAHA Ed. 07 193 / 236


SYMBOL DICTIONARY

- Parameter symbolic name


- In the form of a hexadecimal string of 128 characters
SOn COMPANY NUMBER
- Value of parameter CTA (n: 1 to 1023)
SOC COMPANY NUMBER
- Symbolic name of parameter
- value: 1 to 1023
SONn DIFFERENTIATIED RINGING NUMBER n
- Value of parameter CAT
- 1 ≤ i ≤ 3 (SON1 implicit value)
SPA OUTGOING ONLY LINE
- Value of parameter TY
SPB EXCLUSIVELY I/C LINE
- Value of parameter TY
SPCi PRINT. A FILE ITEM ACCORDING TO A SPECIFIC FORMAT
- Value of parameter.
- Possible values : 1 ≤ i ≤ 8 (value by default = 1).
SPEQ SUB-POSITION OF CIRCUIT EQUIPMENT
- Symbolic name of parameter
SPN Right to the service by number
- Value of parameter CAT for subscriber management.
SPON SPONTANEUS
- Value of parameter.
SPSW TO LIST THE ZONE CONTAINING STATIC DATA OF THE SPS.
- parameter value
- values can be specified for parameters "DEB" and "NSEC".
SRn RESTRICTED SERVICE
- Value of parameter TY
- n is included between 1 and 15
SRn RESTRICTED SERVICE
- Value of parameter CTA
- 1 ≤ n ≤ 15
SR RESTRICTED SERVICE
- Symbolic name of parameter
- Possible value : from 1 to 15
SRAn I/C BARRED ACCESS

194 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter CAT


- n is comprised between 1 and 65535
SRAP CALL SOURCE
- Symbolic name in output lists
SRC ENTITLEMENT TO SUBSCRIBER-CONTROL BARRED ACCESS
- Value of parameter CAT
SREn CALLED PARTY BARRED ACCESS
- Value of parameter CAT
- 1 ≤ n ≤ 15
SRE TYPE OF ALARM: NETWORK MONITORING
- Parameter value
SRNn CLAS OF SERVICE : NIGHT BARRED ACCESS
- Value of parameter TY
- 1 ≤ n ≤ 15
SRS SERVICE WITH DIALLING RECORD
- Value of parameter
- Symbolic name when output
SRV NAME OF SERVICE IDENTIFIER
- Symbolic name of parameter
SRV SERVICE NUMBER
- Parameter symbolic name
SRV NAME OF SERVICE IDENTIFIER
- Symbolic name of parameter
SR0 ROUTING RESTRICTION - ORDER 0
- Value of parameter DIS
SR1 ROUTING RESTRICTION - ORDER 1
- Value of parameter DIS
SR2 ROUTING RESTRICTION - ORDER 2
- Value of parameter DIS
SR3 ROUTING RESTRICTION - ORDER 3
- Value of parameter DIS
SR4 ROUTING RESTRICTION - ORDER 4
- Value of parameter DIS
SR5 ROUTING RESTRICTION - ORDER 5
- Value of parameter DIS
SR6 ROUTING RESTRICTION - ORDER 6

3BW 45305 AAAA RKAHA Ed. 07 195 / 236


SYMBOL DICTIONARY

- Value of parameter DIS


SR7 ROUTING RESTRICTION - ORDER 7
- Value of parameter DIS
SR8 ROUTING RESTRICTION - ORDER 8
- Value of parameter DIS
SR9 ROUTING RESTRICTION - ORDER 9
- Value of parameter DIS
SR10 ROUTING RESTRICTION - ORDER 10
- Value of parameter DIS
SR11 ROUTING RESTRICTION - ORDER 11
- Value of parameter DIS
SR12 ROUTING RESTRICTION - ORDER 12
- Value of parameter DIS
SR13 ROUTING RESTRICTION - ORDER 13
- Value of parameter DIS
SR14 ROUTING RESTRICTION - ORDER 14
- Value of parameter DIS
SR15 ROUTING RESTRICTION - ORDER 15
- Value of parameter DIS
SS SPECIAL SERVICE USED
- Symbolic name printed out
SSC SUB DIAGRAM NAME
- Symbolic name of parameter
SST Switch status
- Symbolic name in edition
- It can take the following values :
• NSIG : Not significant
• NSW : Not switching
• SWC : Switch complete
• SWP : Switch pending
• RF : Release failed
STi Indexing of the non-dedicated routing
- Value of the STY parameter
- 1 ≤ i ≤ 10
STi STANDARD INDEXATION
- Value of parametre STY

196 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- 1≤i≤8
STA SMM STATION
- Value of DV parameter in the INFIN command
- The possible statuses are : AONS, AOS, RO
START OPTIONAL START OF STATISTICS
- Symbolic name of parameter
STB PHYSICAL ADDRESS OF STATION FIRST PART
- Symbolic parameter name
- In the form <s>-<t>-<b>
- <s> Room (1 ≤le s ≤le 9)
- <t> Row (1 ≤le t ≤le 99)
- <b> Rack (1 ≤le b ≤le 99)
STB PHYSICAL ADDRESS OF URA FIRST PART
- Symbolic parameter name
- In the form <s>-<t>-<b>
- <s> Room (1 ≤le s ≤le 9)
- <t> Row (1 ≤le t ≤le 99)
- <b> Rack (1 ≤le b ≤le 99)
STBA SMB GEOGRAPHIC ADDRESS
- Parameter symbolic name
- In the form <s>-<t>-<b>-<a>
- <s> Room (1 ≤ s ≤ 9)
- <t> Row (1 ≤ t ≤ 99)
- <b> Rack (1 ≤ b ≤ 99)
- <a> Shelf (1 ≤ a ≤ 255)
STBBM PHYSICAL ADDRESS OF MAGNETIC TAPE DRIVE FIRST PART
- Symbolic parameter name
- In the form <s>-<t>-<b>
- <s> Room (1 ≤le s ≤le 9)
- <t> Row (1 ≤le t ≤le 99)
- <b> Rack (1 ≤le b ≤le 99)
STBDE PHYSICAL ADDRESS OF POWER DISTRIBUTION SOURCE
- Symbolic parameter name
- In the form <s>-<t>-<b>
- <s> Room (1 ≤le s ≤le 9)
- <t> Row (1 ≤le t ≤le 99)

3BW 45305 AAAA RKAHA Ed. 07 197 / 236


SYMBOL DICTIONARY

- <b> Rack (1 ≤le b ≤le 99)


STC STC analysis discrimination
- Value of DIS parameter, value: 1 to 15
STCn CALL SCREENING PROFILE CATEGORY
- Parameter value
- Possible value : 1 ≤ n ≤ 15
STD OUTPUT ACCORDING TO STRUCTURE
- Parameter value
STD RETURN TO STANDARD INDICATOR
- Symbolic parameter name
- Possible value :
• YES : The customization of the alarm characteristics will be suppressed
STDA DAILY VARIATION OF METERS
- Symbolic name printed out
STOP OPTIONAL HALT OF STATISTICS
- Symbolic name of parameter
STOP REQUEST FOR ARCHIVING STOP
- Value of parameter
STOP OPTIONAL REQUEST FOR ARCHIVING STOP
- Name of parameter
STR NAME OF STRUCTURE
- Symbolic name of parameter
- 6 characters as a maximum
STR PRINT. A FILE ITEM AS PER THE STANDARD STRUCTURE
- Value of parameter.
STRD NAME OF DESTINATION ITEM STRUCTURE
- Symbolic parameter name
- Possible values : 6 characters
- The parameter is the ’KEY’ of a record in the OM structure description file (YSTR).
STRS NAME OF SOURCE ITEM STRUCTURE
- Symbolic parameter name
- Possible values : 6 characters
- The parameter is the ’KEY’ of a record in the OM structure description file (YSTR).
STS SYNCHRONIZATION AND TIME BASE STATION
- Parameter value
STT CHARGING TYPE CHART NUMBER

198 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- Possible value : 1 ≤ STT ≤ 31
STTUS STATUS OF SOFTWARE MACHINE
- Output symbolic name
- Possible values:
- ES, ESRE, INDL, INDO, INIT, NES
STTUS RESULT OF CHECKING A GROUP OF LA
- Output symbolic name
- Possible values:
- ES : In operation
- FLA : LA link fault
STTUS RESULT OF CHECKING AN LCXE LINK
- Output symbolic name
- Possible values:
- ES : In operation
- FLCXE : LCXE link fault
- FCARTE: Board fault
- The LCXE check has detected a matrix board failure.
STTUS ALARM MULTIPLEX STATUS
- Symbolic parameter name
- Possible CVAMO input values :
- BLOM, ES, INDL
- Possible output values :
- BLOM, BLOS, ES, INDL, NEQ
- Status of an alarm multiplex :
• BLOM Manually isolated
The multiplex provides neither remote control processing nor alarm loop pro-
cessing.
• BLOS Isolated by system
Problem for linking the multiplex to the SMM NAT component.
• ES In operation
• INDL Unavailable free
The multiplex does not process alarm loops ; it processes remote control com-
mands in transmission but not in reception; it processes positioning messages.
• NEQ Not fitted
STTUS STATUS OF A STATION ACCESS MULTIPLEX RING
- Symbolic parameter name

3BW 45305 AAAA RKAHA Ed. 07 199 / 236


SYMBOL DICTIONARY

- Possible input values of the command AMXMO :


• ring positioning : ES, BLOM, TEST
• insertion of adapter : INS
• adapter removal : DINS
- Possible output values : NEQ, ES, BLOS, BLOM, TEST
STTUS STATUS OF AN ADAPTER
- Symbolic parameter name
- Possible input values of the command AMXIL: DIAG, DINS
ETAT ETU STATUS
- Symbolic name of parameter
- Parameter settings :
- ES : In service
- NEQ : Not present
- BLOM : Manually isolated
- INDO : Unavailable busy
- INDL : Unavailable free
- TEST : Under test
- INIT : Being initialized
STTUS STATUS OF SYSTEM
- Symbolic parameter name
- Possible values :
- ES , CDPC, CDPIi
- INIGi (only to be used when system started manually)
- Output symbolic name
- In the form <sttus>-<nivs>
- <sttus> System status
- ES , REGEi, CDPC, CDPI0
- INIGi
- <nivs> System operation level
- (1 <= nivs <= 255)
- 64 <= Initialization of control MLs is authorised.
- 48 <= Initialization of exchange management MLs is authorised.
- 32 <= Initialization of the switching matrix is authorised.
- 16 <= Initialization of connection and auxiliary equipment MLs
- is authorised.
- 1 = Messages filtering during incompatible change of release

200 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

<nivs> is not output if it is at 0.


STAT GLR STATUS
- Symbolic parameter name
- Possible values :
- BLOS, ES, FEN, FLA, FLR, FLREi, FLRS, INDL, NEQ, HS
STTUS OM SECONDARY MEMORY STATUS
- Symbolic parameter name
- Possible values:
- NNU, TST, VAL
STTUS EQUIPMENT STATUS
- Value of parameter
- possible value :
- BLOA : Manually blocked (Nº7)
- BLOD : Manually blocked (Nº7)
- BLOF : Blocking wire
- BLOJ : Junction blocking
- BLOM : Manually isolated
- BLOQ : blocked (general)
- BLOS : Isolated by systeme
- DFAU : Semi-error
- ENG : Engaged
- ENGA : Engaged input (Nº7)
- ENGD : Engaged output (Nº7)
- ES : Operating
- ESREG : In regeneration service
- ESRES : Restricted service
- FAUA : Faulty at input (Nº7)
- FAUD : Faulty at output (Nº7)
- HS : out of service
- INDL : Inavailable idle
- INDLS : Inavailable taken for dedicated link
- INDO : Inavailable busy
- INIT : Initialization
- LIBR : Free
- NENG : Non-engaged
- TESA : input equipment on test (Nº7)

3BW 45305 AAAA RKAHA Ed. 07 201 / 236


SYMBOL DICTIONARY

- TESD : output equipment on test (Nº7)


- TEST : Under test
STTUS LIST. OF DIALOGUE TERMINALS PHYS. STATUS
- Symbolic name of parameter
STTUS STATUS OF FAULTS FILTER
- Symbol printout value
- The possible values are ACTIVE or not ACTIVE
STTUS CNSP STATUS
- Name of parameter
- The parameter may take values :
- BLOS Blocked by the system
- LIBR Free
- ENG Busy (or : engaged)
STTUS STATE OF AN OPERATOR POSITION
- Symbolic name in output lists
STTUS QUALITY STATUS OF PCM
- Symbolic name of parameter
- Possible value : QTI.
STTUS BUFFER FILE INTERROGATION
- Value of parameter OPT
- Interrogation of buffer file for intemized billing or fault - alarm - observations or TAXIL.
STTUS BUFFER FILE INTERROGATION
- Value of parameter
STAT STATE OF GLR
- Symbolic output name
- Possible values :
• ES - IN SERVICE
• FLA - LA LINK FAULT
• NS - NO SIGNIFICANT CHECK
STTUS STATUS OF CONTROL STATION
- Symbolic parameter name
- Possible input values according to the command :
• ESMIN :
• BLOM, BLOS, ES, INDL, INDO, INIT, TEST
• HS (encompasses the statuses BLOM, BLOS, INDL, INDO, INIT, TEST)
• ESMMO, CHNMO :

202 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• BLOM, ES, INDL


- Possible output values :
- BLOM, BLOS, ES, INDL, INDO, INIT, NEQ, TEST
STX CHARGE MONITORING
- Value of parameter MAR
STY SUB-TYPE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
STY Routing sub-type
- Symbolic parameter name
- Possible values: SAT, TKO, ST1 to ST10, AXF, CLI, CATDR
STY SUB TYPE OF PTX
- Symbolic name of parameter
- Possible values: SAT,TKO, ST1 to ST8
SU USER SERVICE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
SU USER SERVICE
- Symbolic name of parameter
- Possible values:
- 00 : analog
- 01 : transcom
- 02 : ISDN
- 05 : mobile radio systems
- 12 : general operation
- 14 : routing
SUN UNIDIRECTIONAL SUSPENSION
- DIS Parameter Value
SUP SERVICE SUPPORT
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:

3BW 45305 AAAA RKAHA Ed. 07 203 / 236


SYMBOL DICTIONARY

• hexadecimal number on 1 byte


SUPE NAME OF LFN EXTERNAL INPUT SUPPORT
- Symbolic name of parameter.
- 4 characters indicates the external support .
- If the parametre SUPE is absent, the support is a magtape drive.
SUPP SUPPORT
- Symbolic name of parameter
- The value applied is BM or DC
SUPS NAME OF LFN EXTERNAL OUTPUT SUPPORT
- Symbolic name of parameter.
- 4 characters indicates the external support .
- If the parameter SUPS is absent, the support is a magtape drive.
SURV DATA LINK MONITORING RULES
- Value of parameter DISLD
- Value included between 0 and 2
- 0 : no monitoring :
- 1,2 : monitoring allowed
SURVn DATA LINK MONITORING RULES
- Value of parameter DISL
- Value included between 0 and 1
- 0 : no monitoring :
- 1 : monitoring allowed
SURVi DATA LINK MONITORING RULES
- Parameter value
- Value included between 0 and 2
- 0 : no monitoring :
- 1 : monitoring 15 s
- 2 : monitoring 16 mn
SURV1 UPDATE OF THE NUMBER OF DL WITH SURV = 1
- Value of the CTRL parameter of the LDIL command.
SV NUMBER OF TELEPHONE OPERATOR SUPERVISOR
- Symbolic name of parameter
- Possible values : 0 to 7
SV BLOCK SAVE OPERATION
- Value of parameter OPT
- Backup of a number of blocks of the disk file

204 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- recording the itemized billing data or the


- observation-fault-alarm data-TAXIL.
SVTD BINARY PATTERN ON TS16 OF DATA TRANSMISSION LINKS
- Symbolic name of parameter
- Parameter value : 1 to 15
- Default value : 10
SWC Switch complete
- Value of the parameter SST
SWP Switch pending
- Value of the parameter SST
SYK KEYBOARD SYNTAX FACILITY
- Parameter value
- Parameter : DIS
SYNC ALARM, NO APPLICATION SYNCHRONIZATION
- Symbolic name for printout
SYNC CLOCK SUPPLY TO THE STS.
- Parameter symbolic name
- Possible values
- BUSA, BUSB
SYS OUTPUT AT SYSTEM LEVEL
- Parameter value
SYS SYSTEM DATA
- Parameter value
SZHi RACK FOR VARIOUS UNITS i
- Value of parameter (1 ≤ i ≤ 4)
S2F 2-WIRES EQUIPMENT WITH EQUALIZATION AND SWITCHABLE GAIN
- Output symbolic name
S2F16 UT HAVING 16 DISCRIMINATED 2-WIRE BASIC EQUIPMENTS WITH EQUALIZATION
- Value of parameter
S2Z16 UT HAVING 16 DISCRIMINATED 2-WIRE BASIC EQUIPMENTS WITH ETSI COMPLEX
IMPEDANCE
- Value of parameter
S3F 3-WIRES EQUIPMENT WITH EQUALIZATION AND SWITCHABLE GAIN
- Output symbolic name
S3F16 UT HAVING 16 DISCRIMINATED 3-WIRE BASIC EQUIPMENTS WITH EQUALIZATION
- Value of parameter

3BW 45305 AAAA RKAHA Ed. 07 205 / 236


SYMBOL DICTIONARY

S3Z16 UT HAVING 16 DISCRIMINATED 3-WIRE BASIC EQUIPMENTS WITH ETSI COMPLEX


IMPEDANCE
- Value of parameter
T DURATION OF TEMPORARY OBSERVATION
- Symbolic name of parameter
- The value is applied in the form : <hour>-<minute>, where hour varies from 0 to
32 767 and minute varies from = to 59
T TRAFFIC
- Value of parameter
T MALFUNCTION MESSAGE TYPE
- Output symbolic name
- Possible values from 0 to 15
T WORKING AREA
- Parameter value
T DURATION OF TEMPORARY OBSERVATION
- Symbolic name of parameter
- The value is applied in the form : <hour>-<minute>, where hour varies from 0 to
32 767 and minute varies from = to 59
T TOTAL DURATION OF THE TESTS OF ECHO CANCELLER
- Parameter symbolic name
T TEMPORARY NETWORK CHARACTERISTICS
- Parameter value
T FILE OF TEMPORARY TYPE
- Parameter value
TA INCOMING TRAFFIC PROCESSED BY THE LINE GROUP
- Symbolic name in output lists
TA TYPE OF NUMBERING
- Symbolic name for output
- Data read from the magnetic tape of detailed billing
- Value numeric on 1 byte
TAB TABLE NAME
- Symbolic name of parameter
TAC WAIT TIME DELAY BETWEEN FIGURES CONTAINED IN THE FIPAM FILE
- Symbolic name of parameter
TAMP STORAGE OF CHARGE METERS ON DISK
- Value of parameter OPT
TANS TYPE OF SIGNALLING ANALYSIS

206 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- symbolic output name (5 characters)


- possible value :
- INDIV : individual
TAP CALL TYPE
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• hexadecimal number on 1 byte
TATMC ATM TRAFFIC (COMPLETE EDITION)
- Value of parameter
TATMR ATM TRAFFIC (REDUCED EDITION)
- Value of parameter
TAUX LIST OF OCCUPANCY RATES
- Symbolic name of parameter.
- Rate in the form a+b
- 1 ≤ Rate ≤ 99
TAX NUMBER OF CHARGES ALLOCATED
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• decimal value in 1 to 8 digits
TAX SUBSCRIBER CHARGE ACCOUNT
- Symbolic name printed out
- Value on 24 bits
TAX CHARGE METER
- Parameter value
- Used to save the charge meter values of files FITAX and FICLX in the XATX archive.
TAX TYPE OF ALARM: CHARGING
- Parameter value
TAX CHARGE METER
- Parameter value
- Used to save the charge meter values of files FITAX and FICLX in the XATX archive.
TAXC TESTED CHARGE METERS
- Parameter value
- Used to save and test consistency between the two ML TXs, the charge meter values
of files FITAX and FICLX in the XATX archive.
TC TYPE OF COMMUNICATION

3BW 45305 AAAA RKAHA Ed. 07 207 / 236


SYMBOL DICTIONARY

- Symbolic name for output


- Data read from the magnetic tape of detailed billing
- Value numeric on 1 byte
TCA TIME-DIVISION/ATM CONVERSION
- Parameter value
TCFL MAX. ACCEPTABLE RATE OF RELEASE FAULTY CIRCUITS NOT UNDER SIGNALLING SYS-
TEM Nº 7
- Symbolic name of parameter
- Possible values : 0 to 100
TCHS MAX. ACCEPTABLE RATE OF OUT-OF SERVICE CIRCUITS IN A CIRCUIT GROUP
- Symbolic name of parameter
- Possible values : 0 to 100
TCM No. OF ASSOCIATED REMOTE CONTROL
- Symbolic name of parameter
- Possible value : 1 ≤ n ≤ 8
TCO LINE CONTINUITY
- Parameter value
- Continuity check for the digital subscriber tests
TCTF MAX. ACCEPTABLE RATE OF SEMI-FAULT CIRCUITS IN AN O/G CIRCUIT GROUP NOT
UNDER SIGNALLING SYSTEM Nº7
- Symbolic name of parameter
- Possible values : 0 to 100
TCT1A TU FOR INTERFACE STM1 - DAISY CHAIN (EXTERNAL LINK)
- Value of parameter
TCT1B TU FOR INTERFACE STM1 - DAISY CHAIN (EXTERNAL LINK)
- Value of parameter
TD DATA TRANSMISSION OVER SIGNALLING LINK SET
- Value of parameter GENR
TD DATA TRANSMISSION OVER SIGNALLING LINK SET
- Symbolic name printed out
TDA ACCUSATION RATE
- Symbolic name printed out
TDAM AVERAGE ACCUSATION RATE OF A UNIT OR TYPE OF UNIT
- Symbolic name printed out
TEI NUMBER OF THE ITA TERMINAL
- Symbolic name of parameter
- Possible value : from 1 to 63

208 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

TEMPO TIME DELAY USED IN TESTING


- Symbolic name of parameter
TEMPO CTX VALIDITY DURATION BEFORE SWITCHING TO CTXS
- Symbolic name of parameter
- Value from 0, 20, 30, ... by step of 10 seconds until ... 250.
TEMPO MINIMUM DURATION OF OCCUPACY OF A REC BEFORE EDITION
- Symbolic name of parameter.
- 0 ≤ tempo ≤ 32767
TEMP1 TIME DELAY VALUE
- Parameter symbolic name
- The value is assigned in the form: <SEC>-<S/10>
- SEC : number of seconds between 0 and 60
- S/10 : number of tenths of second between 0 and 99
- The value must be between 5 tenths and 60 seconds inclusive
TEMP2 TIME DELAY VALUE
- Parameter symbolic name
- The value is assigned in the form: <HH>-<MN>
- HH between 0 and 24 inclusive
- MN between 0 and 59 inclusive
- The value must be between 1 minute and 24 hours inclusive
TENR RATE OF FAILURES DUE TO NO ANSWER
- Symbolic name in output lists
TEO RATE OF FAILURE DUE TO OCCUPATION
- Symbolic name printed out
TESA INPUT EQUIPMENT Nº 7 ON TEST
- Value of parameter
TESD OUTPUT EQUIPMENT Nº 7 ON TEST
- Value of parameter
TEST EQUIPMENT IN TEST
- Value of parameter
TEST TEST FUNCTION
- Value of the parameter CACT in operator command FZTMOS.
TEST MULTIPLEX RING ON TEST
- Parameter value
- The operator has initiated the ring repair test.
TEST CONTROL STATION ON TEST

3BW 45305 AAAA RKAHA Ed. 07 209 / 236


SYMBOL DICTIONARY

- Parameter value
- The SM is undergoing automatic or operator command LOCAVAR.
- The SM is "out of service".
TEST ETU UNDER TEST
- STATUS or symbolic name in an output line
- The ETU is not handling traffic
TEXAL ALARM TEXT
- Symbolic name printed out
TEXAL TEXT OF THE ALARM
- Symbolic parameter name.
- Possible value: a string of 20 characters maximum.
TE155 Value of the parameter PRF
TF ERROR MESSAGE TYPE FUNCTION
- Symbolic name of parameter
- 0 ≤ type ≤ 15 and 0 ≤ function ≤ 15
TF VALUE OF THRESHOLD OF EFFICIENCY RATE
- Symbolic name of parameter
TF No. OF TARIFF ASSOCIATED TO A RATE TIMEBAND
- Symbolic name of parameter
- Possible value : 1 ≤ TF ≤ 16
TFAU FAULTY CALLS RATE PER URA/FAULTY CIRCUITS PER URC
- Symbolic name printed out
TFCT FUNCTIONAL TYPE OF A DIGITAL CONCENTRATOR
- Symbolic name of parameter
- The value is supplied in the form of a character string
- Possible values :
• CNLA, CNLM, GTA
• CNEA, CNEM, CNES, CNEP
• CNLH, CNEH, CNSH, CNPH
• CNLB, CNEB, CNSB, CNPB
TFCT FUNCTIONAL TYPE OF TERMINAL UNIT
- Symbolic name of parameter
- The value is indicated in the form of a string of characters
- Possible values :

210 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

MNEMO associated boards


O2F16 TABA16,TABAS,TABASB,TABAK
O2F16 TABAZ
FLC32 TFLC
S2F16 TABAE,TABAF
S2Z16 TABAZF
D2F08 TABAD
O2A04 TADSL
ARQ04 TAN4F,TNA4F2
ABA04 TABN,TNAT
ADL04 TADL
ADP01 TADP
ACP01 TADPB
AQP08 TABNP
TFILM TFILMB
VABA VAB16
V5132 TCV51
POS TPOL
POSA TPOS
POSX TCPOLX
TCT1A TCTB1
TIBD1 TCIBD1
TCT3A TCTB3
TIBD3 TCIBD3
O3F16 TABA16,TABAS,TABASB,TABAK AND TFLC
O3Z16 TABAZ AND TFLC
I2F16 TABA16I
S3F16 TABAE, TABAF AND TFLC
S3Z16 TABAZF AND TFLC
D3F08 TABAD AND TFLC
ABQ04 TABN,TN4F
ABE08 TNAE,TNAE2
DQF04 TDQF
UTP TUTP
AQE08 TAN1Q,TAN3G
AQA04 TNDSL

3BW 45305 AAAA RKAHA Ed. 07 211 / 236


SYMBOL DICTIONARY

MNEMO associated boards


RFC08 TRF8B
VADL VDL16
VPOS VPOS
POSM TPOL AND TMLA
POSAM TPOS AND TMLA
POSX TCPOSX AND TMLA
TCT1B TCTB1B
TMF04 TCATMF

TFILM 4 RECORDED ANNOUCEMENT EQUIPMENTS (UT)


- Value of parameter
TF1 TARIFF APPLIED BY CHARGING UNIT 1
- Symbolic output name.
- Additional information from the alarm signalling a variation in the fixing of the price
scale applied by the two charging units.
TF2 TARIFF APPLIED BY CHARGING UNIT 2
- Symbolic output name.
- Additional information from the alarm signalling a variation in the fixing of the price
scale applied by the two charging units.
TH RATE TIME BAND
- Symbolic name of parameter
- Possible value : 1 to 8
• TH = 1 : First hour in autonomous operation.
• TH = 2 : Second hour in " "
• TH = 3 : Third hour in " "
• TH = 7 : Seventh hour in autonomous operation.
• TH = 8 : Additional time after the seventh hour.
TIBD1 TRANSPORT TU STM1 - SECONDARY DAISY CHAIN
- Value of parameter
TID TYPE OF IDENTIFICATION OF CALLING ENTITY
- Value of parameter CTA
TIMQ Value of the timing marqueur
- Symbolic name of parameter
- It can take following values :
• G811
• G812T

212 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• G812L
• SETS
• UQ
• DNUS
TINDL RELEASE TIME DELAY
- Symbolic name of parameter
- Possible values : 1 to 90
- Value expressed in minutes.
- This parameter is used to limit the length of wait time for release of a station.
- If the station is not released, it is set in BLOM status when the time delay expires.
TITHS RATE OF TIME SLOTS OUT OF SERVICE
- Symbolic name of parameter
- The value is given in percentage
TKO CIRCUIT DEDICATED TO OPERATOR TRUNK OFFER
- Value of parameter
TKO ROUTING OR PARAMETER OF TAXATION TYPE ACCORDING TO THE INCOMING OP-
ERATOR SOURCE CIRCUIT GROUP
- Value of the STY parameter
TKO TYPE OF PARAMETER OF TAXATION ACCORDING TO THE INCOMING OPERATOR
SOURCE CIRCUIT GROUPE
- Value of parameter STY
TLC SUBSCRIBER ON CONCENTRATOR
- Value of parameter
TLC REMOTE CONTROLS ACTIVABLE AT THE START OF THE ALARM
- Symbolic parameter name
- Possible values: from 1 to 32
TLCA REMOTE CONTROLS ACTIVABLE UPON ALARM ACKNOWLEDGE
- Symbolic parameter name
- Possible values: from 1 to 32
TLCS INDICATOR LAMP FOR THE USE OF THE STANDARD ASSIGNMENT
- Symbolic parameter name
- Possible values :
• YES : The remote controls defined for the alarm type and category are activated
as well as the remote controls of the actual alarm.
• NO : Only the remote controls of the alarm are activated (the remote controls
corresponding to the alarm type-category pair are not activated).
TM MANUAL CHARGE RATE
- Value of parameter MDTX

3BW 45305 AAAA RKAHA Ed. 07 213 / 236


SYMBOL DICTIONARY

TMAE ETU OF TYPE: PCM TERMINATION WITH ECHO CANCELLATION DEVICE


- Parameter setting
- Symbolic name in an output line
TMF04 4-EQUIPMENTS ATM FORUM 4 WIRES
- Value of parameter
TMIC PCM TERMINATION FUNCTION
- Value of the parameter FACT.
TMIC PCM TERMINATION ETU
- Parameter setting
- Symbolic name in an output line
TMP TEMPORARY DATA
- Parameter value.
TMP NAME OF BUFFER LFN
- Parameter symbolic name
TNR RATE OF FAILURE CAUSED BY ABSENCE OF ANSWER
- Symbolic name printed out
TNS TRANSMISSION DOWNSTREAM OF THE CARRIER NUMBER USED TO ROUTE THE CALL.
- Value of the DIS parameter
TOAG AGENT OCCUPANCY RATE
- Symbolic name printed out
TONI INTERMEDIATE TONE
- Symbolic name of parameter
- Possible values : 1 to 15
TOT TOTAL CALL LIMITATION
- Value of parameter ESP
TO1S Value of the parameter PRF
TPR Indicates the type of pair under test.
- Symbolic name of parameter
- Possible values:
- 0 = Reception
- 1 = Transmission
- Default value: 0
TR CALLING CIRCUIT AUTHORIZED TO USE OUTGOING ROUTING
- Value of parameter
TR TRANSLATOR GROUP
- Value of parameter

214 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

TR GROUP OF SUBSCRIBER AND ANALYSIS DATABASE MANAGER MLs


- Parameter value
TR TYPE OF CONNECTION ASSOCIATED WITH THE GLR
- Symbolic output name
- Possible vlaues :
• GLR - GLR between network and end
• LAH(Q) - LAH(Q) GLR between network and end
• GLR+LAH(Q) - GLR at network level and LAH(Q) at end level
TX ML TX
- TYML parameter value
TRAn CARRIER NUMBER BY SUBSCRIPTION FOR TRAFFIC A
- Value of parameter CAT
- 1 ≤ n ≤ 9999
TRA TYPE OF ALARM: TRANSMISSION
- Parameter value
TRADi ANALYSIS FILE NUMBER
- Value of parameter CAR
- 1 ≤ i ≤ 15
TRAD ANALYSIS FILE NUMBER
- Symbolic name of parameter
- Possible values : 1 to 15
TRAF TYPE OF TRAFFIC FOR WHICH A SUBS. MUST BE OBSERVED
- Symbolic name of parameter
- Takes values :
• A : I/C traffic
• D : O/G traffic
• or A + D
- For OAPLA observation, only the values D and A+D are authorised.
TRAF TRAFFIC DISPERSION MEASUREMENT
- Value for TYOBS parameter
TRAJ NETWORK PATH OF A DATA LINK
- Symbolic name of parameter
- Possible value :
• 1 : data link with a reconfigurated network path (OCB181)
• 2 : data link with no network path (OCB181 and OCB283)
TRAN DEMANDS OF NMEA FOR THE SET OF SMS CONNECTED TO THE RING

3BW 45305 AAAA RKAHA Ed. 07 215 / 236


SYMBOL DICTIONARY

- Symbolic name printed out


TRAS NEXT ANALYSIS FILE NUMBER
- Parameter value
- From 1 to 15
TRAU TRANSCODER AND RATE ADAPTATOR UNIT
- Symbolic name of the parameter
- Possible values : 1 to 64
TRAVEE RACK SUITE NUMBER
- Symbolic name output
- Decimal integer (over 3 digits)
TRBn CARRIER NUMBER BY SUBSCRIPTION FOR TRAFFIC B
- Value of parameter CAT
- 1 ≤ n ≤ 9999
TRAn CARRIER NUMBER BY SUBSCRIPTION FOR TRAFFIC C
- Value of parameter CAT
- 1 ≤ n ≤ 9999
TRCSNi TYPE OF CONNECTION FROM THE CSN TO THE CDC
- Parameter value
- Possible value of i :
- 0 : connection by links with 2 MBIT/S (any type of CSN)
- 1 : connection by 1 link with 30 MBIT/S (remote CSNHD)
- 2 : connection by 2 links with 30 MBIT/S (remote CSNHD)
TRCXi SWITCHING MATRIX TYPE IN THE CSN UGCX
- Value of parameter
- Possible value for i : 0 = UCX CSN HD
- 1 = 16 LRIX (CSN 1G)
- 2 = 32 LRIX (CSN 1G)
- 3 = 48 LRIX (CSN 1G)
TREL ACTUAL OBSERVATION TIME
- SYMBOLIC OUTPUT NAME
TRI INTERNAL TRAFFIC
- Values for ENT parameter
TRL LENGTH OF INTERNAL DESIGNATION NUMBER BLOCK
- Symbolic name of parameter
TRN NUMBER OF INTERNAL DESIGNATION NUMBER BLOCK
- Symbolic name of parameter

216 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

TRND FIRST DESIGNATION NUMBER IN THE BLOCK


- Symbolic name of parameter
TRON VALUE USED FOR M-LEAD
- Symbolic name of parameter
TRR NETWORK PATH RECONFIGURATION
- Value of parameter TYMO
TRS LIST OF TRANSACTIONS FOR STATISTICS
- Symbolic name of parameter
TRSB DIGITS OF ND FOR PACKET B (TRANSGROUPE SUBSCRIBER)
- Symbolic name of parameter
- 1 to 16 digits.
TRT R2 TRANSIT ENABLED
- Value of parameter
TR1 TRANSLATOR GROUP 1
- Parameter value
TR1 SUBSCRIBER AND ANALYSIS DATABASE MANAGER ML 1
- Parameter value
TR2 TRANSLATOR GROUP 2
- Parameter value
TR2 SUBSCRIBER AND ANALYSIS DATABASE MANAGER ML 2
- Parameter value
TSAT TOTAL SATURATION RATE OF OUTPUT MESHES
- Symbolic name printed out
TSCi TYPE OF SERVICE OF NUMBER
- Value of DIS parameter
- 1 ≤ i ≤ 15
TSM MULTIPLEX SIGNALLING TERMINAL
- Symbolic name output
- From 0 to 15
TST SECONDARY MEMORY UNDER TEST
- Parameter value
TSV VIRTUAL SIGNALLING TERMINAL
- Symbolic name of parameter
- Possible values : From 1 to 7 (E10B 181)
- : From 1 to 15 (E10B 283)
- The value 0 printed out means the safety TSV

3BW 45305 AAAA RKAHA Ed. 07 217 / 236


SYMBOL DICTIONARY

TTATCi TRAFFIC THROUGH TCA/CAT LAYER (COMPLETE EDITION)


- Value of parameter
- Possible values: 1 ≤ i ≤ 4
TTATR TRAFFIC THROUGH TCA/CAT LAYER (REDUCED EDITION)
- Value of parameter
TTB CHARGE-RATE VALUE APPLIED TO BASIC CHARGE UNIT
- Symbolic name of parameter
TTRS NUMBER OF THE TTRS CARD
- Symbolic name of parameter
- Possible values :
• 2 to 15 for ICDC
• 16 to 57 for ICNE
TTX REMOTE CHARGING INDICATION
- Symbolic name on output
- Output during reading of TLV France format itemized billing type magnetic tape
- Possible values:
• 0 or 1
TTX PRIVATE METER
- Value of parameter
TTXn ENTITLEMENT TO REMOTE CHARGING SERVICE, SYSTEMATIC FOR ALL CALL
- Value of parameter CAT
TX CHARGING METERS GROUP
- Value of parameter
TX GROUP OF CALL CHARGING AND TRAFFIC MEASUREMENT MLs
- Parameter value
TX ML TX
- TYML parameter value
TXB COST OF BASIC METERED UNIT
- Symbolic name of parameter
TXCD CHARGE METERING IN REMOTE SWITCHING CENTRE
- Value of parameter MDTX
TXD DELAYED CHARGING
- Symbolic name of parametre
- Possible values: YES - NO (NO is implicit)
TXML EFFICIENCY RATE OF COMPONENT ML
- Symbolic name printed out

218 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

TXSE SERVICE EFFICIENCY RATE


- Symbolic name printed out
TXSQL FRACTION OF SEQUENCER TIME CONSUMED BY THE SLOW REGISTERS
- Symbolic name printed out
TXT CONTENT OF DATA WRITTEN TO TAPE
- Symbolic name of parameter
- List of the characters to be stored on tape
TX1 CHARGING UNIT NO. 1
- Parameter value
TX1 CALL CHARGING AND TRAFFIC MEASUREMENT ML 1
- Parameter value
TX2 CHARGING UNIT NO. 2
- Parameter value
TX2 CALL CHARGING AND TRAFFIC MEASUREMENT ML 2
- Parameter value
TYn TELEPRINTER
- Value of parameter
TY TYPE OF SUBSCRIBER LINES
- Symbolic name of parameter
- Possible values :
- ACT, ACP2, ACPS, ACPU, ACT2, ACTU, AEMn, AREn, CAD, CCAn, DQAn, DQBn,
- DQ1, DQ2, DQ3, DRV, DSM, DTMF, EQCn, EXLS, FLA, GABAn, IBR, ICR, IELP
- IIB, INTB, KLA, LCLn, LFL, LSS, MOD, MIX,
- NBAn, NBSn, NCAn, NCBn, PDE, PRACn, PRAD, RR, SCA, SEn, SPA, SPB, SRn
- TLC, TTX, TYPOn, TYQn, UPR, VPNE, V51, V52.
With :
- AEMn : 1≤ n ≤ 3
- AREn : 1≤ n ≤ 3
- CCAn : 1≤ n ≤ 4
- DQAn : 1≤ n ≤ 15
- DQBn : 1≤ n ≤ 7
- EQCn : 1≤ n ≤ 3
- GABAn : 1≤ n ≤ 8
- NBAn : 1≤ n ≤ 31
- NBSn : 1≤ n ≤ 2
- NCAn : 1≤ n ≤ 30

3BW 45305 AAAA RKAHA Ed. 07 219 / 236


SYMBOL DICTIONARY

- NCBn : 1≤ n ≤ 30
- LCLn : 1≤ n ≤ 3
- PRACn : 2≤ n ≤ 3
- SEn : 1≤ n ≤ 30
- SRn : 1≤ n ≤ 15
- TYPOn : 1≤ n ≤ 2
- TYQn : 1≤ n ≤ 15
TY TYPE OF ROUTING FOR RATES TIMEBANDS
- Symbolic name of parameter
- AC1 routing 1 of the multiple routing
- AC2 routing 2 of the multiple routing
- AC3 routing 3 of the multiple routing
TYAN TYPE OF NETWORK ACCESS
- Symbolic parameter name
- Possible values:
• ANi
TYBXT TYPE OF EXPANSION RACK OF A CSN
- Symbolic name of parameter
- Possible values: 0 rack of the CSN 1G type
- 1 rack of the CSN HD type
TYC SIGNALLING TYPE AND CODE OF A TERMINAL CIRCUIT
- Symbolic name of parameter
TYCA BOARD TYPE
- Parameter symbolic name:
- possible values: 0 ≤ TYCA ≤ 32767
TYCO COMPONENT TYPE
- Symbolic parameter name
TYCO TYPE OF COMPONENT
- Symbolic name printed out
TYCP TYPE OF CP
- Symbolic name of parameter
- Possible values :
• PSTN : analogue
• ISDNS : digital
TYF FUNCTIONAL TYPE
- Symbolic name output

220 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

TYFAn TYPE OF ADDITIONAL SERVICE


- Value of parameter CAR
- Possible value 1 ≤ n ≤ 31
TYFAC TYPE OF FACILITY
- Symbolic name of parameter
- Value in the form : <TYFA>-<TYPU>
- TYFA : Type of facility
- Possible values : 1 to 31
- TYPU : Type of use for the facility
- Possible values : 1 to 15
TYFIL CHECK TYPE
- Value of DISLD parameter
- Possible values :
• 0 : no check (eg. local announcement machine)
• 1 : modulation check (eg. remote announcement)
• 2 : check on data presence (eg. CCBT broadcasting)
TYFILi CHECK TYPE
- Parameter value
- Possible values :
• 0 : no check (eg. local announcement machine)
• 1 : modulation check (eg. remote announcement)
• 2 : check on data presence (eg. CCBT broadcasting)
TYFUR UR FUNCTION TYPE
- Symbolic name at output
- Form <UR Type>-<complementary type>
• UR type :
- URC : Circuits connection unit
- URAL : Local subscribers connection unit
- URAD : Remote subscribers connection unit
- IRM : Multiples connection interface
- IRS : Satellite connection interface
TYJ TYPE OF DAY REQUESTED
- Symbolic name of parameter
- Possible value : 0 ≤ TYJ ≤ 15
TYJO TYPE OF DAY
- Symbolic name of parameter

3BW 45305 AAAA RKAHA Ed. 07 221 / 236


SYMBOL DICTIONARY

- The value given to the parameter varies from :


- 0 to 7 for commands TAXMO and CALMO and from
- 1 to 7 for the other commands
TYLB TYPE OF GENERAL PURPOSE LFN
- Symbolic name of parameter
- The parameter can take the values :
• DIFF : Deferred
• SPON : Spontaneus
TYLD TYPE OF DATA LINK
- Symbolic name of parameter
- Value included between 1 and 8 (and 14,15 if broadcast data link)
TYLD TYPE OF DATA LINK
- Symbolic name of parameter
- Value included between 1 and 8 (and 14,15 if broadcast data link)
TYM TYPE OF CONNECTION UNIT EQUIPMENT
- Symbolic name of parameter
- Values of parameter :
• CSE : Electronic subscriber connection unit
• CSN : Subscriber digital access unit
• URA2G : Second-generation subscriber connection unit
TYMIC PCM TYPE
- Symbolic name of parameter
- Possible values :
• 0 : Normal bit-rate PCM
• 1 : Intermediate bit rate PCM
TYML ML TYPE
- Symbolic name of parameter
- 32-bit hexadecimal number (H’xxxxxxxx’)
- The bit of row i corresponds to the ML type of number i.
- Broadcast is limited to the support stations of the MLs identified by the parameter.
For example, if TYML=H’40800400’, broadcast takes place on the support stations
of the MLs of which the type is 1 (ML MQ), 8 (ML ETA) or 21 (MLCC).
TYML TYPE OF ML
- Symbolic parameter name
- The parameter may have one of the following values:
- CC : Call control ML
- CO2G: Second generation matrix switch controller ML

222 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- COM : Matrix switch controller ML (first generation)


- ETA : Auxiliary equipment manager ML
- GS : IN and GSM server controller ML
- GX : Matrix system handler ML
- HD : High rate lines controller ML
- MQ : Message distributor ML
- MR : Call handler ML
- OC : Message router ML
- PC : SS No. 7 controller ML
- PUPE: SS No. 7 protocol handler ML
- SM : Control station ML
- TX : Call charging and traffic measurement ML
- URM : PCM controller ML
TYMO TYPE OF DATA LINK MODIFICATION
- Symbolic name of parameter
- Parameter values :
• TRR : recongiguration of a network path
• IDLS : modification of LS identifier
TYO TYPE OF OBSERVATION FOR PATHFINDING
- Symbolic name of parameter
- Takes values : B : international bloking
- O : subscriber occupation
TYOBS TYPE OF OBSERVATION
- Symbolic name of parameter
- Possible values are :
APP,INEF,APP+INEF,APP+TRAF,APP+TRAF+INEF
TYP SERVICE TYPE
- Parameter symbolic name
- Possible value :
• INEX : Service not used
• OFF : Service not available
• ON : Service available without restriction
• COND : Service available with restriction
TYP LIST OF TYPES OF COUNTERS TO BE OBSERVED
- Symbolic parameter name
- The parameter may have one of the following values:

3BW 45305 AAAA RKAHA Ed. 07 223 / 236


SYMBOL DICTIONARY

• ETU 63VC12
• QLIN : Quality of SDH lines
• QSPATH: Quality of paths
• Q15MN : Frozen SDH performance counters over 15 mins.
• Q24H : Frozen SDH performance counters over 24 hours
• C15MN : Current SDH performance counters over 15 mins.
• C24H : Current SDH performance counters over 24 hours
• ETU BB
• QTC : Quality convergence transmission
• QPPATH: Quality path for PDH interface
• Station
• RPML : Processor resources per ML
• RPAG : Agent PPC processor resources
• RMMB : MMB resources
• RLAB : LAB resources
• RSST : SST resources (coupler MLSMs)
• ML agent
• RCML : Communication resources
• RSL : LDS resources
• RMMB : MMB resources
• RLAB : LAB resources
• SST
• RSST : SST resources (coupler MLSMs)
• Other
• RMR : Resources specific to ML MR (MR sequencer counters).
• RUTC : Resources specific to ML PUPE (counters per channel).
• RHDLC : Resources specific to HDLC ULIs on MLSMs agents to HDLC PQUICCs.
TYP REJEX TEST INDICATOR
- Symbolic name of parameter
TYP CHARGING TYPE NUMBER
- Symbolic name of parameter
- Possible value : 1 ≤ TYP ≤ 5
TYP TYPE OF ANALYSIS OF A MAGNETIC TAPE
- Symbolic name of parameter
- Possible values :
- ABO output of the suscriber observations requested

224 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- JDB output of the status report records requested


- STX output of the charging synchronization
- FD output of the billing details requested
- TAX output of the charge accounts
- OBS output of the requested observations
- ANO output of the requested anomalies
- ALA output of the requested alarms
- AUD output of charging audit items
TYP TYPE OF ALARM
- Symbolic parameter name
- Possible values :
• COM : Switching
• ICT : Switching - transmission interface
• ENP : Primary power
• EFF : Burglary
• CLI : Air conditioning
• CHA : Heating room
• INC : Fire
• SRE : Network monitoring
• TAX : Charging
• EXP : Explosimeter
• INO : Flood
• DIV : Miscellaneous
• ENS : Secondary power
• TRA : Transmission
TYPA TYPE OF ALARM
- Symbolic name of parameter
- Possible values for the commands
• ALASU :
• BSMM , INITG
TYPC TYPE OF CONFIGURATION
- Symbolic name of parameter
- 0 ≤ value ≤ 99
TYPE TYPE OF TRANSFER
- Symbolic name of parameter
- Possible value from 0 to 7

3BW 45305 AAAA RKAHA Ed. 07 225 / 236


SYMBOL DICTIONARY

• Type = 0 : variable call forwarding unconditional


• Type = 1 : preset call forwarding or Manager/Secretary facility
• Type = 3 : variable call forwarding on busy
• Type = 4 : variable call forwarding on no reply
• Type = 5 : fixed call forwarding unconditional
• Type = 6 : fixed call forwarding on busy
• Type = 7 : fixed call forwarding on no reply
TYPE TYPE OF TERMINAL
- Symbolic name of parameter
- Type of terminal to be remod or modified
- TYPE = CV or IR or TY
TYPE i TYPE OF OBJECT OBSERVED
- Symbolic name in output list

NUMBER OF OBJECTS
TYPE 1 TYPE 2 TYPE 3 TYPE 4
No. of sub-
If OAB
scriber lines
No. of sub-
If OLX
scriber lines
Number of cir-
If OTF
cuits
No. of INDs No. of ACHs No. of URAs No.of NFSCs
If OTD
No. of MSs No. of SEs
If OMA
No. of URAs
If ORI
No. of circuit No. of URAs
If OCH
group
No. of URAs
If OTP
No. of NFSPs
If TCN
No. of MTTs
If OLI
No. of circuits No. of circuit
If OFC
group
No. of desti- No. of URAs No of circuit
If ODS
nations group

TYPE ROUTING TYPE


- Symbolic name of parameter

226 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Possible values : From 1 to 21 (except 18 and 19)


TYPE PTX EXTERNAL TYPE
- Symbolic name of parameter
TYPE FILE TYPE
- Symbolic parameter name
- Possible values for the commands:
• ARCRG, ARCSV :
• P, S, T
• IDLIN :
• ALL, P, PS, S, T
• P as default
TYPF METHOD OF ACCESS TO A FILE
- Symbolic name of parameter
- Takes values :
• DEV : implicit, not organized
• DIR : direct access
• KEY : access through key in item
TYPG GENERAL TYPE / TYPG = TFCT+TYPCi+TRCXk+TRCSNj
- Symbolic name of parameter.
- TFCT can be given the following symbol values :
- URAL, URAD, IRM, IRS
- TYPCi configuration type : i varies from 0 to 99
- TRCXk LRIX configuration of the UCX :
• k = 1 : 16 LRIX
• k = 2 : 32 LRIX
• k = 3 : 48 LRIX
- TRCSNj type of connection from the CSN to the CDC
• j = 0 : connection by links with 2 MBIT/S (any type of CSN)
• j = 1 : connection by 1 link with 30 MBIT/S (remote CSNHD)
• j = 2 : connection by 2 links with 30 MBIT/S (remote CSNHD)
TYPM TYPE OF EQUIPMENT
- Symbolic name of parameter
TYPO FUNCTIONAL TYPE OF THE OBJECT OR TRANSMIT UNIT
- Symbolic name of parameter
- Source of a malfunction or alarm item on a magnetic tape of type OPFA
TYPOn TYPE OF OPERATOR POSITION (SUPERVISOR)

3BW 45305 AAAA RKAHA Ed. 07 227 / 236


SYMBOL DICTIONARY

- Value of parameter TY
- n=1
TYPP Protection type
- Symbolic name of parameter
- It can take the following values
• UNID
TYPP TYPE OF POSITIONING
- Symbolic name of parameter
- Possible values :
• BOF : positioning on a file beginning
• EOF : positioning behind last block of the last file
• EOV : positioning behind the last file
TYPRF SORT OF PREFIX - TYPE OF PREFIX FOR THE CSN
- Symbolic name of parameter
- Value in the form : <GPREF>-<TPREF>
- GPREF : Sort of prefix
- Possible values : 1 to 15
- TPREF : Type of prefix
- Possible values : 1 to 15
TYPS TYPE OF JUMP OR OF POSITIONING
- Symbolic name of parameter
- Possible values :
• RB : on-line rewinding
• SB : data blocks forward jump
• SBB : data blocks rearward jump
• SF : tape mark forward jump
• SFB : tape mark rearward jump
TYPUn TYPE OF FACILITY UTILIZATION
- Value of parameter CAR
- Possible value 1 < n < 15
TYQn CONNECTED EQUIPMENT TYPE
- Value of parameter TY
- Refer to operating data
TYR SIGNALLING NETWORK TYPE
- Parameter code
- Possible values:

228 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

• RN, RL, RI, R4, R5, R6, R7, R8


TYR TYPE OF SIGNALLING NETWORK
- Symbolic name of parameter
- Possibles values :
• RN : national network (by default)
• RL : local network
• RI : international network
• Ri : network i (4 =< i =< 8)
TYR TYPE OF SIGNALLING NETWORK
- Symbolic name of parameter
- Possibles values :
• RN : national network (by default)
• RI : international network
• Ri : network i (4 =< i =< 8)
TYSM SM TYPE NUMBER
- Symbolic name of parameter
- Number logged in the "system data log" document
TYSMB SMB TYPE NUMBER
- Parameter symbolic name: TYSMB
- possible values: 1 ≤ TYSMB ≤ 32767
TZG TYPE OF GEOGRAPHIC ZONE TO SWITCH TO THE NEW NUMBERING SCHEME
- Symbolic name output
Ui URBAN CIRCUITS
- Value of parameter
- Possible value : 1 ≤ i ≤ 15
UNID Non revertif unidirectional 1+1
- Value of the parameter TYPP
UPR PRIORITY LINE
- Value of parameter TY
UQ Unknown quality
- Value of the parameter TIMQ
UR CONNECTION UNIT
- Symbolic name printed out
- Operating mode of directed calls in opposition to "percent"
URA SUBSCRIBER CONNECTION UNIT NUMBER
- Symbolic name of parameter

3BW 45305 AAAA RKAHA Ed. 07 229 / 236


SYMBOL DICTIONARY

URAD REMONTE SUBSCRIBER CONNECTION UNIT


- Value of parameter
- Use of URAD in AFSEM : The end involved is the remote end
URAL LOCAL SUBSCRIBER CONNECTION UNIT
- Value of parameter
URA2G SECOND-GENERATION SUBSCRIBER CONNECTION UNIT
- Value of parameter
URG URGENT CALL
- Value of parameter DIS
URMi PCM CONTROLLER ML GROUP i
- Parameter value (1 ≤le i ≤le 64)
URMi PCM CONTROLLER ML GROUP i
- Parameter value (1 ≤le i ≤le 64)
URM ML URM
- TYML parameter value
URMAi PCM CONTROLLER ML i - LOGIC SUBUNIT A
- Parameter value (1 ≤le i ≤le 64)
URMBi PCM CONTROLLER ML i - LOGIC SUBUNIT B
- Parameter value (1 ≤le i ≤le 64)
UROB FUNCT.ADDRESS OF UR’S TESTING EQUIP. FOR SUBSC.
- Symbolic name of parameter
USINE OM INITIALIZATION FOR FACTORY TESTS
- Parameter value
This mode allows the function OM to be initialized and all stations of the OCB to be
set to "BLOM".
The LOCAVAR function of the stations includes dedicated features allowing "factory"
tests to be carried out.
This initialization option is saved for future use.
UTi TERMINAL UNIT
- Symbolic name of parameter
UTC OM ARCHIVE OF ML PC AND ML PUPE
- AFCMD parameter value
UTC CSS 7 MULTIPROCESSOR
- Value of parameter
UTP FRAME PROCESSING MODULE UT
- Value of parameter
UVL PREMARKING WITH/WITHOUT VOLUME UVL1 LABEL

230 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Symbolic name of parameter


- UVL = O (YES) : label UVL 1 writing belind label vol 1
V TERMINAL SPEED
- Symbolic name of parameter
MITRA
- V = 0 or 1168
OMC83
- V = 300, 600, 1200,
- 2400, 4800, 9600
VAB16 VIRTUAL TU VABA (ACCES NETWORK) WITH 16 EQUIPMENTS
- Value of parameter
VAL SUCCESSION OF VALUES TO BE ENTERED IN UNIT-FILE
- Symbolic name of parameter
- 16 hexadecimal values as a maximum in the form
- H’----’ for command FORMO
VAL MODIFICATION VALUE
- Symbolic parameter name.
VAL SECONDARY MEMORY ENABLED
- Parameter value
VALI
- Parameter value.
- Work file enable, leading to its change-over with the corresponding reference file.
VAL MODIFICATION VALUE
- Symbolic name of parameter.
VAR V5.2 INTERFACE VARIANT
- Parameter code name
- Any value from 0 to 127
VARM MEMORY VARIANCE COEFFICIENT
- Parameter symbolic name:
- possible values: 0 ≤ VARM ≤ 255
VB LIMITS OF TIME RANGES
- Symbolic name of parameter
- List of 4 (obligatory) positive values USED for determining the time ranges for function
OTP
VDL16 VIRTUAL UT VADL (ACCES NEYWORK)
- Value of parameter
VERS V5.2 INTERFACE VERSION

3BW 45305 AAAA RKAHA Ed. 07 231 / 236


SYMBOL DICTIONARY

- Parameter code name


- Any value from 0 to 255
VNA UNASSIGNED ANALOG V5.1 ACCES
- Output symbolic name
VNM UNASSIGNED ANALOG OR DIGITAL V5.1 ACCES
- Output symbolic name
VOICI OMC CONNECTION EXCHANGE CODE VOICI
- Symbolic name of parameter
VOL NAME OF VOLUME
- Symbolic name of parameter
- 6 characters as a maximum filed in volume VOL 1 label,and used identify a magtape
VPNE m ENTITLEMENT TO SIGNALLING OF ACCESS, DSS1+
esym.
- Value of parameter TY
VPOS POSITIONING VIRTUAL TU
- Value of parameter
VPRG PROTOCOL VERSIONS LINKED TO THE SERVER
- Symbolic name of parameter
- In the OiTj mnemonic form
- -Oi= protocol operation version with i from 1 to 9
- -Tj= TCAP protocol version with j from 1 to 9
VS THRESHOLD VALUE TO BE APPLIED TO CHARGING METER
- Symbolic name of parameter
- Limit values : 0 to 100 for percentages or rates 0 to 32 767 for number or events
VSGi SIGNALLING CODE VARIANT
- Value of parameter CTA
- 1 ≤ i ≤ 15
VTSM MULTIPLEX SIGNALLING TERMINAL LINK
- Symbolic name output
- Possible values :
• on SMB : from 0 to 252
• on SMA : from 0 to 63
VTSV MULTIPLEX SIGNALLING TERMINAL LINK
- Symbolic name output
- Possible values :
• on SMB : from 0 to 252
• on SMA : from 0 to 63

232 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

VV IRM PCM LINK CONVEYING CHANNEL-ASSOCIATED SIGNALLING


- Symbolic name of parameter
- Possible values : YES or NO
V5A ANALOG V5.1 ACCES
- Output symbolic name
V5N DIGITAL V5.1 ACCES
- Output symbolic name
V23 DISTRIBUTION INDEX CCF/V23
- Symbolic name of parameter
- Index for distribution between the CCF and V23 functions for the auxiliary boards of
an SMA.
- Number logged in the "system data log" document
- Value between 0 and 4, 0 by default.
V23HS LIMIT ALARM V23 OUT OF SERVICE
- Symbolic name of parameter
- Attributed value in number
V51 V5.1 LINE UNIT
- TY parameter value
V5132 UT OF V5.1 INTERFACE
- Value of parameter
V52 CONNECTION UNIT V5.2
- SYMBOLIC NAME OUTPUT
V52 SUBSCRIBER WITH V52 EQUIPMENT
- TY parameter value
V52A V5.2 LINE UNIT ASSIGNED TO ANALOGUE LINE
- symbolic name in edition
V52B V5.2 LINE UNIT ASSIGNED TO DIGITAL LINE WITH BASIC ACCESS
- Symbolic name in edition
V52P V5.2 LINE UNIT ASSIGNED TO DIGITAL LINE WITH PRIMARY RATE ACCESS
- Symbolic name in edition
WFD LENGTH OF DATA TO BE WRITTEN TO TAPE
- Symbolic name of parameter
- Par 1 = from 1 to 240
WORD WORD ADDRESS TO BE MODIFIED
- Symbolic name of parameter
MOT SEARCH BYTE
- Symbolic name of Parameter.

3BW 45305 AAAA RKAHA Ed. 07 233 / 236


SYMBOL DICTIONARY

- Hexadecimal string of 16 bytes maximum.


WTM WRITING A TAPE MARK
- Symbolic name of parameter
- Par 1 = 1 for single TAPE MARK
- Par 1 = 2 for double TAPE MARKS
XC TRANSMISSION OF A VARIABLE-LENGTH MESSAGE WITH RESPONSE
- Value of parameter
XD TRANSMISSION OF A VARIABLE-LENGTH MESSAGE WITH DELAYED ANSWER
- Value of parameter
XI TRANSMISSION OF A VARIABLE-LENGTH MESSAGE WITH IMMEDIATE ANSWER
- Value of parameter
XM TRANSMISSION OF A VARIABLE-LENGTH MESSAGE WITHOUT ANSWER
- Value of parameter
XON TYPE OF TRANSMISSION MODE
- Value of parameter
XU NUMBER OF FIELDS INTERCHANGED FROM ACCESS TO ACCESS (XU LIST)
- Symbolic name for output
- OUTPUT FIELD READ FROM THE MAGNETIC TAPE OF DETAILLED BILLING TYPE
- Possible values:
• DECIMAL NUMBER BETWEEN 0 AND 255
XXX UNDETERMINED TYPE OF EQUIPMENT
- Symbolic name printed out
O SUBSCRIBER OCCUPIED
- Value of parameter
O ACCEPTED, AUTHORIZED
- Parameter value
YES ACCEPTANCE, AUTHORIZATION
- Parameter value
YES TRANSPORT QUALITY OBSERVATION IN COMPLEMENT OF THE MULTIPLEX OBSERVA-
TION
- Value of parameter QUAL
YES PRINTOUT OF QUALITY COUNTER
- Value of parameter ED
YES PRESENCE OF A BROADCAST DATA LINK (LD) ALARM
- Symbolic output name
YES TRANSPORT QUALITY OBSERVATION IN COMPLEMENT OF THE MULTIPLEX OBSERVA-
TION

234 / 236 3BW 45305 AAAA RKAHA Ed.07


SYMBOL DICTIONARY

- Value of parameter QUAL


YES PRINTOUT OF QUALITY COUNTER
- Value of parameter
YES YES
- Parameter value
YES ACCEPTANCE, AUTHORIZATION
- Value of parameter.
Z WORK AREAS
- Value of parameter
Z AUTOMATIC TRANSPONDER RESETTING
- Value of parameter
ZGn GEOGRAPHIC AREA
- Value of parameter
- 1 ≤ n ≤ 256 (default value : ZG1)
ZG GEOGRAPHIC AREA
- Symbolic name printed out
- Possible value : from 1 to 64
ZLTn LOCAL SORTING AREA
- Value of parameter
- 1 ≤ n ≤ 64 (default value : ZLT1)
ZOND DESTINATION OM ARCHIVE OR FILE CARRIER AREA
- Symbolic parameter name
- Possible values:
• R : Reference area
• T : Working area
• The working area is used when there is a change of technical release.
ZONEZ LIST SSOM COMMON DATA ZONE.
- Parameter value
- The common data zone comprises a set of segments.
- Parameters "DEB" and "NSEC" can be specified. They are meaningful for all segments
to be listed. Parameter "noseg" can also be specified.
ZONS SOURCE OM ARCHIVE OR FILE CARRIER AREA
- Symbolic parameter name
- Possible values:
• R : Reference area
• T : Working area
• The working area is used when there is a change of technical release.

3BW 45305 AAAA RKAHA Ed. 07 235 / 236


SYMBOL DICTIONARY

ZTXn CHARGING AREA


- Value of parameter
- 1 ≤ n ≤ 128 (default value : ZTX1)

236 / 236 3BW 45305 AAAA RKAHA Ed.07

S-ar putea să vă placă și