Documente Academic
Documente Profesional
Documente Cultură
GE INSPECTION TECHNOLOGIES
Michael Zhang
E&E Reliability Lab
Test Report
Report No: SHRL90028/2008
Page: 2 of 3
Date: Sep. 18, 2008
We have tested the submitted sample(s) as requested and the following results were obtained:
Test Equipment:
Name Model
Dust Chamber SC-6
Degree of protect against water equipment T041101-01
Test 1. IPX4
Protection against ingress of water
Oscillating angle: 180°/side
Oscillating speed: 4seconds/cycle
Tube radius: 1000mm
Numbers of open holes: 41
Water flow rate 0.07L/min±5%/ hole
Test duration: 10minutes
Test Result(s): Satisfied
No water enters into the sample after the dust-protected test.
Photos: